Model BF 260 Incubators Avantgarde.Line with forced convection

Similar documents
Model BF 56 Standard-Incubators with forced convection

Model BF 720 Incubators Avantgarde.Line with forced convection

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Model KB 23 Cooling incubators with compressor technology

Model KB 720 Cooling incubators with compressor technology

Model KT 115 Cooling incubators with thermoelectric cooling

Model FD 23 Drying and heating chambers Classic.Line with forced convection

Model FDL 115 Safety drying chambers for limited quantities of solvent

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Environmental simulation chamber for cyclical temperature

KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions

SECURE.GUARD Ultra low temperature freezer

CHL Laboratory refrigerators

Constant climate chambers KBF KBF P KBF LQC KMF

CYTOPERM 2 CO 2 - AND CO 2

SCO Series - Air Jacketed Units. SHEL LAB CO2 Incubators

Thermo Scientific Heraeus Cytoperm 2 CO 2 and CO 2 /O 2 Incubator

TEMPERATURE CHAMBER (+5 C +180 C) TK-50 CK TK-105 CK TK-190 CK TK-340 CK TK-500 CK TK-1000 CK

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

B.O.D. INCUBATOR. Model no.: ACM I TECHNOLOGIES PVT. LTD.

testo 335 New measurement engineering for monitoring emissions

LABORATORY AUTOCLAVES

GALAXY DIRECT HEAT CO 2 INCUBATORS EXPANDING THE CELL CULTURE UNIVERSE WITH SUPERIOR PERFORMING LITER SYSTEMS

ENCORE 2G MEDIUM LABORATORY STERILIZER SPECIFICATION/DATA SHEET

FITOCLIMA WALK-IN STABILITY

FITOCLIMA WALK-IN STABILITY

Helping Make Safe & Reliable Products Because people count on your products everyday

Compact flue gas analyser: testo 300 M-I

Furnaces for Research and Laboratory. Testing Drying Ashing Tempering Preheating Sintering Firing Annealing

MODEL NO. - ACM I TECHNOLOGIES PVT. LTD.

Thermo Scientific Heracell VIOS 160i CO 2. Incubator with Cell Locker System. Protected chambers for your most sensitive cells

400 C WHT 4/30 WHT 4/60 WHT 4/ C WHT 5/30 WHT 5/60 WHT 5/ C WHT 6/30 WHT 6/60 WHT

Stability test and plant growth chembers. EKOCT - EKOCTL - EKOCH - EKOCHL Series

Thermo Scientific Heracell VIOS 160i CO 2. Incubator with Cell Locker System. Protected chambers for your most sensitive cells

Debinding Ovens. for Ceramics

SpeedExtractor E-916 / E-914 Technical data sheet

AS950 ALL-WEATHER REFRIGERATED SAMPLER

Price list valid:

FITOCLIMA 600 & 1200 BIO

MODEL NO. - ACM Q SEROLOGICAL WATER BATH

Tinytag Transit 2. Manual

Welland Series. Outstanding features

MIR COOLED INCUBATORS

Depyrogenation Oven. depyrogenation and dry heat sterilization

Tank Scale Service Checklist

Thermal Shock Test Chambers TS Series

Technical System Catalogue Modular PDU (PSM)

Gyrolab xp workstation

PRODUCT VT C LOW TEMP. FREEZERS SPECIFICATIONS FEATURES DIMENSIONS LOADING QUANTITIES BIOMEDICAL SOLUTIONS

SAFETY PROCESS INDUSTRY LABORATORY & RESEARCH

EBI 100 Precision Data Loggers

Using the PPM2 Portable Trace Moisture Transmitter

VARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model

Anyvib Vibration Test Chambers

F1 1/10 R&D BIOREACTORS/FERMENTORS

FITOCLIMA 600 & 1200 BIO

Lightning Speed superb acceleration rates with temperature shock test chambers

Welland Series. Outstanding features

AS950 REFRIGERATED SAMPLER

EBI 25 Wireless Data Logger System

Transport Boxes. Active & Passive. Biomedical Refrigeration I MT. Technology for life

High Speed... Rapid Temperature Change Rates with VTS & VCS Stress Screening Systems

Low Temperature Check. Automatic instrument for the determination for both TR TEST and BRITTLENESS POINT

ENDOSCOPIC REPROCESSING ETD DOUBLE Advancing the Efficiency of Reprocessing.

F2 15/30 SIP PILOT SCALE BIOREACTORS

SPECIFICATION. Ir-192 hot cell

Ref. No. NITD/BT/NM/RIG#2/ /1 Date: 01/03/2017 To,

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY:

RENA XPS-3000 Base. User Guide. SC2000 Media Transport System

Reference flue gas analyzer

AQUALAB 4TE, 4TEV, 4TE DUO, 4TEV DUO BENCHTOP WATER ACTIVITY

VARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model

Laboklav. Type 55 to 195 Liter. Technical Datasheet. Dampfsterilisatoren Steam sterilizers

Thermo Scientific Sorvall BIOS 16 Centrifuge. performance simplified. at every turn

F2 15/30 SIP PILOT SCALE BIOREACTORS

INSTALLATION MANUAL MULTI DECK HOT MERCHANDISERS MD Versions. Solid back 3 level Pass through 3 level

Flue gas analyzer for industry

Optimizing Performance Bench Scale Service Checklist

GALAXY DIRECT HEAT CO 2 INCUBATORS EXPANDING THE CELL CULTURE UNIVERSE WITH SUPERIOR PERFORMING LITER SYSTEMS

64C Amplification Block. Instruction Manual

STERIVAP SL. Compact and Economic Steam Sterilizer for Health Industry. protecting human health

Multi-function VAC measuring instrument

Differential pressure measuring instrument

STERIVAPHP. Original without compromises. protecting human health. new line steam sterilizers

Supply and installation of nine elevators for Sharafat Social Housing Project in Beit Safafa - Jerusalem Bill of Quantities

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Humidity/temperature measuring instrument

Low Temperature Testers

During the 1980 s, in order to satisfy an enquiry from an important North American company in the medical field, Gandus Saldatrici designed and began

AirBench EX Operation and Maintenance

Customer Responsibilities

Humidity/temperature measuring instrument

AW/VW SERIES. Weighing systems. PTCHRONOSASIA.com

Highly efficient flue gas analyser with Bluetooth

BOD-3009 INCUBATOR EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

Installation Qualification/Operational Qualification Protocols and Instructions

TARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DPX fume extraction systems

Transcription:

Model BF 260 Incubators Avantgarde.Line with forced convection The BINDER incubator of the BF Avantgarde.Line series with forced convection is suitable for all gentle incubation applications, particularly under a full load and large batch throughputs. This incubator is extremely homogeneous and has quick recovery times. BENEFITS Excellent temporal and spatial temperature accuracy High process reliability 100 C disinfection routine MAIN FEATURES Model 260 Model 260 Temperature range: ambient temperature plus 7 C to 100 C High temperature accuracy thanks to APT.line technology Forced convection Controller with LCD display Electromechanical control of the exhaust air flap Inner door made of tempered safety glass 2 chrome-plated racks Class 3.1 integrated independent temperature safety device (DIN 12880) with visual alarm Ergonomic handle design USB port for recording data ORDERING INFORMATION Interior volume [cu.ft.] Voltage Option model Version Art.-No. Model BF 260 9.1 230 V 1 ph 50/60 Hz Standard BF260-230V 9010-0319 120 V 1 ph 60 Hz Standard BF260UL-120V 9010-0320 TECHNICAL DATA Description BF260-230V 1 BF260UL-120V 1 Article Number 9010-0319 9010-0320 Performance Data Temperature Temperature range 7 C above ambient temperature to [ C] 100 100 Temperature variation at 37 C [± K] 0.2 0.2 Temperature fluctuation at 37 C [± K] 0.1 0.1 Heating-up time to 37 C [min] 7 7 Recovery time after 30 seconds door open at 37 C [min] 3 3 1 All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 C ±3 C and a power supply voltage fluctuation of ±10%. The temperature data is determined to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time. Page 1 / 5

Description BF260-230V 1 BF260UL-120V 1 Article Number 9010-0319 9010-0320 Electrical data Rated Voltage [V] 230 120 Power frequency [Hz] 50/60 60 Nominal power [kw] 0.9 1 Unit fuse [A] 8 12.5 Phase (Nominal voltage) [ph] 1 1 Outer dimensions Width net [mm] 810 810 Height net [mm] 965 965 Depth net [mm] 760 760 Wall clearance back [mm] 160 160 Wall clearance sidewise [mm] 100 100 Doors Unit doors 1 1 Internal Dimensions Width [mm] 650 650 Height [mm] 780 780 Depth [mm] 510 510 Measures Interior volume [L] 257 257 Net weight of the unit (empty) [kg] 85 85 permitted load [kg] 270 270 Load per rack [kg] 40 40 Environment-specific data Energy consumption at 37 C [Wh/h] 65 65 Sound-pressure level [db(a)] 43 43 Fixtures Number of shelves (std./max.) 2/8 2/8 1 All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 C ±3 C and a power supply voltage fluctuation of ±10%. The temperature data is determined to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time. DIMENSIONS incl. fittings and connections [mm] Page 2 / 5

OPTIONS AND ACCESSORIES Designation Description * Art.-No. Access port with silicone plug left 10 mm 01 8012-1274 30 mm 01 8012-1156 50 mm 01 8012-1164 right top 10 mm 01 8012-1267 30 mm 01 8012-1153 50 mm 01 8012-1162 10 mm 01 8012-1261 30 mm 01 8012-1150 50 mm 01 8012-1159 100 mm 01, 10 8012-1166 Analog output 4-20 ma for temperature values (output not adjustable) 02 8012-1622 Calibration certificate, expanded Calibration certificate, temperature for temperature; for extending the measurement in center of chamber to include another test temperature 8012-1111 for temperature, measurement in center of chamber at specified temperature 8012-1130 temperature measurement incl. certificate and 27 at specified temperature 8012-1590 temperature measurement incl. certificate, 15-18 at specified temperature 8012-1569 temperature measurement incl. certificate, 9 at specified temperature 8012-1548 Cart Cart stable cart, casters with locking brakes, dimensions: W 1,300 x D 800 x H 780 mm 9051-0019 Clock battery-backed 8012-1639 Data Logger Kit Data Logger Software T 220: For continuous temperature logging from -90 C to 220 C. The kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) 19 8012-0715 19 8012-0821 Door lock lockable door handle 8012-1663 Ethernet interface for communication software 8012-0990 Gas-tight option model Inert gas connection Interior lighting Interior socket Incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option With gas inlet and outlet, Ø 10 mm, incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option with 15 W light bulb 09 8012-1046 8012-1049 120 V option model 8012-0971 230 V option model 8012-1626 Waterproof, switched flush-mounting box (CA3GD) for nominal voltage in unit interior, with cover and corresponding plug (nominal voltage; max. 500 W; max. 90 C; protection class IP67) 07 8012-1638 Overheating alarm audible, can be switched off, adjustable limit on the independent temperature safety device 8012-1634 ph-neutral detergent concentrated, for gentle remove of residual contaminants; 1 kg 1002-0016 Pt 100 temperature sensor additional flexible Pt 100, interior, for displaying the temperature on the unit display 8012-1618 Rack, heavy load Stainless steel, max. load per rack 70 kg 6004-0200 Racks chrome-plated 6004-0169 stainless steel 6004-0153 Shelf, perforated Stainless steel 6004-0185 Software * Notes See last page APT-COM communications software version 2 to 3, GLP edition 19 9053-0016 version 3, BASIC edition 19 9053-0014 version 3, GLP edition 19 9053-0015 version 3, STANDARD edition 19 9053-0013 APT-COM communications software, price: for free version 3, GLP DEMO Edition 19 9053-0008 Page 3 / 5

SERVICES Designation Description * Art.-No. Installation services Installation and set up of unit at operating location, connect to existing connections 13, 18 DL10-0100 Instruction unit function instructions for operation and programming of the controller 18 DL10-0400 Preventive maintenance Preventive maintenance Executive of equipment inspection according to maintenance plan 14, 18 DL20-0200 Calibration services Calibration temperature incl. certificate including certificate, one measuring point in center of chamber at specified temperature DL30-0101 Temperature measurement 18 including certificate, 18 at specified temperature DL30-0118 Temperature measurement 27 including certificate, 27 at specified temperature DL30-0127 Temperature measurement 9 including certificate, 9 at specified temperature DL30-0109 Validation services Execution of IQ/OQ in accordance with qualification folder 15, 18, 20 DL40-0100 Execution of IQ/OQ/PQ in accordance with customer's requirement, price: on request 15, 18 DL44-0500 Qualification folder IQ/OQ supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 15, 18, 20 8012-0871 Qualification folder IQ/OQ/PQ Warranty service supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ 15, 18 8012-0959 Extension of the warranty from 2 to 3 years Extension of the warranty from 2 to 5 years beginning with the date of delivery, wearing parts are not included DL01-7041 beginning with the date of delivery, wearing parts are not included DL01-7042 * Notes See last page Page 4 / 5

NOTES 01 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge. 02 UL mark is not granted when this option is used. 03 Heat resistant only to max. 200 C. 04 Only available on units rated for 230 V. 06 Heating-up time may increase as a result of the lower heat conductivity. 07 The additional heat input may affect the temperature behavior. 09 Not in conjunction with the optional access port, door with window and interior lighting. 10 Not available on 23-liter units. 11 Not available on 23- or 53-liter units. 12 Only available on units rated for 230 V or 400 V. 13 Installation and connections take place at unit location; transport within the company only upon consultation. 14 We recommend a BINDER service contract to cover unit inspections, calibrations and validations. 15 OQ according to Yellow Paper = completed factory validation documentation of all OQ checklists. 16 Sensor calibration is performed in an accredited calibration laboratory. 17 Calibration is performed according to the BINDER factory standard. 18 Quoted prices do not include travel costs. Please refer to the chapter on BINDER Service for travel costs for your region. Quoted prices for services performed in Switzerland do not include a country-specific added fee (available on request). 19 For additional accessories, refer to the Process documentation chapter. 20 When ordering IQ/OQ qualification folders and associated IQ/OQ execution on one order, we offer a 15 % discount for the item of the IQ/OQ folder. When ordering IQ/OQ/PQ qualification folders and associated IQ/OQ/PQ execution on one order, we offer a 15 % discount for the item of the IQ/OQ/PQ folder. Page 5 / 5