Model BF 720 Incubators Avantgarde.Line with forced convection

Similar documents
Model BF 260 Incubators Avantgarde.Line with forced convection

Model BF 56 Standard-Incubators with forced convection

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Model KB 23 Cooling incubators with compressor technology

Model KB 720 Cooling incubators with compressor technology

Model KT 115 Cooling incubators with thermoelectric cooling

Model FD 23 Drying and heating chambers Classic.Line with forced convection

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Model FDL 115 Safety drying chambers for limited quantities of solvent

Environmental simulation chamber for cyclical temperature

KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions

CHL Laboratory refrigerators

SECURE.GUARD Ultra low temperature freezer

Constant climate chambers KBF KBF P KBF LQC KMF

CYTOPERM 2 CO 2 - AND CO 2

SCO Series - Air Jacketed Units. SHEL LAB CO2 Incubators

Thermo Scientific Heraeus Cytoperm 2 CO 2 and CO 2 /O 2 Incubator

TEMPERATURE CHAMBER (+5 C +180 C) TK-50 CK TK-105 CK TK-190 CK TK-340 CK TK-500 CK TK-1000 CK

B.O.D. INCUBATOR. Model no.: ACM I TECHNOLOGIES PVT. LTD.

Tinytag Transit 2. Manual

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

400 C WHT 4/30 WHT 4/60 WHT 4/ C WHT 5/30 WHT 5/60 WHT 5/ C WHT 6/30 WHT 6/60 WHT

FITOCLIMA WALK-IN STABILITY

FITOCLIMA WALK-IN STABILITY

AS950 ALL-WEATHER REFRIGERATED SAMPLER

MODEL NO. - ACM I TECHNOLOGIES PVT. LTD.

Stability test and plant growth chembers. EKOCT - EKOCTL - EKOCH - EKOCHL Series

SpeedExtractor E-916 / E-914 Technical data sheet

Technical System Catalogue Modular PDU (PSM)

testo 335 New measurement engineering for monitoring emissions

Thermal Shock Test Chambers TS Series

LABORATORY AUTOCLAVES

Depyrogenation Oven. depyrogenation and dry heat sterilization

ENCORE 2G MEDIUM LABORATORY STERILIZER SPECIFICATION/DATA SHEET

MODEL NO. - ACM Q SEROLOGICAL WATER BATH

VARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model

Welland Series. Outstanding features

Thermo Scientific Sorvall BIOS 16 Centrifuge. performance simplified. at every turn

Anyvib Vibration Test Chambers

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Helping Make Safe & Reliable Products Because people count on your products everyday

GALAXY DIRECT HEAT CO 2 INCUBATORS EXPANDING THE CELL CULTURE UNIVERSE WITH SUPERIOR PERFORMING LITER SYSTEMS

Welland Series. Outstanding features

Compact flue gas analyser: testo 300 M-I

ENDOSCOPIC REPROCESSING ETD DOUBLE Advancing the Efficiency of Reprocessing.

AS950 REFRIGERATED SAMPLER

Low Temperature Check. Automatic instrument for the determination for both TR TEST and BRITTLENESS POINT

Furnaces for Research and Laboratory. Testing Drying Ashing Tempering Preheating Sintering Firing Annealing

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

VARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model

Debinding Ovens. for Ceramics

Thermo Scientific Heracell VIOS 160i CO 2. Incubator with Cell Locker System. Protected chambers for your most sensitive cells

Price list valid:

Lightning Speed superb acceleration rates with temperature shock test chambers

Thermo Scientific Heracell VIOS 160i CO 2. Incubator with Cell Locker System. Protected chambers for your most sensitive cells

High Speed... Rapid Temperature Change Rates with VTS & VCS Stress Screening Systems

Alto CareChair Commode Chair ISO classification Stainless steel, aluminium, composite plastic Date of manufacture 12.02

Transport Boxes. Active & Passive. Biomedical Refrigeration I MT. Technology for life

GETINGE HS44 STERILIZERS FOR HIGH CAPACITY AT POINT OF USE. Always with you

MIR COOLED INCUBATORS

Gyrolab xp workstation

Ref. No. NITD/BT/NM/RIG#2/ /1 Date: 01/03/2017 To,

Laboklav. Type 55 to 195 Liter. Technical Datasheet. Dampfsterilisatoren Steam sterilizers

Optimizing Performance Bench Scale Service Checklist

DPX fume extraction systems

BAUSCH + STRÖBEL. Technical Specification SP100/200 SP3060. Filling machine for bottles Page 1 of 6

Flue gas analyzer for industry

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Indoor Air Quality Tools

Servo-hydraulic Universal Testing Machine HUT Type B

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

Tank Scale Service Checklist

EBI 100 Precision Data Loggers

Supply and installation of nine elevators for Sharafat Social Housing Project in Beit Safafa - Jerusalem Bill of Quantities

Mechatronic pressure measurement. Applications. Special features. Description

FITOCLIMA 600 & 1200 BIO

Differential pressure measuring instrument

Low Temperature Testers

SPECIFICATION. Ir-192 hot cell

SBX 1000 In Situ Oxygen Transmitter

RENA XPS-3000 Base. User Guide. SC2000 Media Transport System

Melting Point M-565 Technical data sheet

During the 1980 s, in order to satisfy an enquiry from an important North American company in the medical field, Gandus Saldatrici designed and began

EBI 25 Wireless Data Logger System

INDeX Rack Installation Notes

BOD-3009 INCUBATOR EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

UBC Technical Guidelines Section Edition Fume Hoods Page 1 of 5

AirBench EX Operation and Maintenance

Just a few clicks away from a heating system diagnosis.

AQUALAB 4TE, 4TEV, 4TE DUO, 4TEV DUO BENCHTOP WATER ACTIVITY

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY:

SAFETY PROCESS INDUSTRY LABORATORY & RESEARCH

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

Highlights HIGH-PRECISION ROBUST MEASUREMENT SYSTEM INDEPENDENT FROM PRODUCT PROPERTIES. System

User s Manual & Installation Guide

Just a few clicks away from a heating system

SERVO-HYDRAULIC UNIVERSAL TESTING MACHINE SERIES A

Using the PPM2 Portable Trace Moisture Transmitter

The Fast and Robust Flue Gas Measuring Instrument for All Important Parameters

User Manual. Precision Balances XSR models

Transcription:

Model BF 720 Incubators Avantgarde.Line with forced convection The BINDER incubator of the BF Avantgarde.Line series with forced convection is suitable for all gentle incubation applications, particularly under a full load and large batch throughputs. This incubator is extremely homogeneous and has quick recovery times. BENEFITS Excellent temporal and spatial temperature accuracy High process reliability 100 C disinfection routine MAIN FEATURES Temperature range: ambient temperature plus 10 C to 100 C High temperature accuracy thanks to APT.line technology Forced convection Controller with LCD display Electromechanical control of the exhaust air flap Inner door made of tempered safety glass 2 chrome-plated racks Class 3.1 integrated independent temperature safety device (DIN 12880) with visual alarm Ergonomic handle design USB port for recording data ORDERING INFORMATION Interior volume [cu.ft.] Voltage Option model Version Art.-No. Model BF 720 25.9 230 V 1 ph 50/60 Hz Standard BF720-230V 9010-0321 240 V 1 ph 60 Hz Standard BF720UL-240V 9010-0322 TECHNICAL DATA Description BF720-230V 1 BF720UL-240V 1 Article Number 9010-0321 9010-0322 Performance Data Temperature Temperature range 10 C above ambient temperature to [ C] 100 100 Temperature variation at 37 C [± K] 0.3 0.3 Temperature fluctuation at 37 C [± K] 0.1 0.1 Heating-up time to 37 C [min] 15 15 Recovery time after 30 seconds door open at 37 C [min] 4 4 1 All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 C ±3 C and a power supply voltage fluctuation of ±10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time. Page 1 / 5

Description BF720-230V 1 BF720UL-240V 1 Article Number 9010-0321 9010-0322 Electrical data Rated Voltage [V] 230 240 Power frequency [Hz] 50/60 60 Nominal power [kw] 1.75 1.85 Phase (Nominal voltage) [ph] 1 1 Outer dimensions Width net [mm] 1165 1165 Height net [mm] 1590 1590 Depth net [mm] 870 870 Wall clearance back [mm] 160 160 Wall clearance sidewise [mm] 100 100 Doors Inner doors 2 2 Unit doors 2 2 Internal Dimensions Width [mm] 1000 1000 Height [mm] 1300 1300 Depth [mm] 565 565 Measures Interior volume [L] 734 734 Net weight of the unit (empty) [kg] 166 166 permitted load [kg] 315 315 Load per rack [kg] 45 45 Environment-specific data Energy consumption at 37 C [Wh/h] 130 130 Sound-pressure level [db(a)] 43 43 Fixtures Number of shelves (std./max.) 2/16 2/16 1 All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 C ±3 C and a power supply voltage fluctuation of ±10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time. DIMENSIONS incl. fittings and connections [mm] Page 2 / 5

OPTIONS AND ACCESSORIES Designation Description * Art.-No. Access port with silicone plug left 10 mm 01 8012-1274 30 mm 01 8012-1156 50 mm 01 8012-1164 right top 10 mm 01 8012-1267 30 mm 01 8012-1153 50 mm 01 8012-1162 10 mm 01 8012-1261 30 mm 01 8012-1150 50 mm 01 8012-1159 100 mm 01, 10 8012-1166 Analog output 4-20 ma for temperature values (output not adjustable) 02 8012-1622 Calibration certificate, expanded Calibration certificate, temperature for temperature; for extending the measurement in center of chamber to include another test temperature 8012-1111 for temperature, measurement in center of chamber at specified temperature 8012-1130 temperature measurement incl. certificate and 27 at specified temperature 8012-1590 temperature measurement incl. certificate, 15-18 at specified temperature 8012-1569 temperature measurement incl. certificate, 9 at specified temperature 8012-1548 Clock battery-backed 8012-1639 Data Logger Kit Data Logger Software T 220: For continuous temperature logging from -90 C to 220 C. The kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) 19 8012-0715 19 8012-0821 Door lock lockable door handle 8012-1816 Ethernet interface for communication software 8012-0991 Inner chamber, reinforced Interior lighting Interior socket max. total load 350 kg 8012-1829 with two 15 W light bulbs 230/240 V option model 8012-1823 Waterproof, switched flush-mounting box (CA3GD) for nominal voltage in unit interior, with cover and corresponding plug (nominal voltage; max. 500 W; max. 90 C; protection class IP67) 07 8012-1638 Load management to comply with EMC requirements in accordance with EN 61326-1:2013-07 (IEC 61326-1:2012) 8012-1820 Overheating alarm audible, can be switched off, adjustable limit on the independent temperature safety device 8012-1634 ph-neutral detergent concentrated, for gentle remove of residual contaminants; 1 kg 1002-0016 Pt 100 temperature sensor additional flexible Pt 100, interior, for displaying the temperature on the unit display 8012-1618 Rack, heavy load Stainless steel, max. load per rack 70 kg 6004-0204 Racks chrome-plated 6004-0171 stainless steel 6004-0155 Shelf, perforated Stainless steel 6004-0187 Software * Notes See last page APT-COM communications software version 2 to 3, GLP edition 19 9053-0016 version 3, BASIC edition 19 9053-0014 version 3, GLP edition 19 9053-0015 version 3, STANDARD edition 19 9053-0013 APT-COM communications software, price: for free version 3, GLP DEMO Edition 19 9053-0008 Page 3 / 5

SERVICES Designation Description * Art.-No. Installation services Installation and set up of unit at operating location, connect to existing connections 13, 18 DL10-0100 Instruction unit function instructions for operation and programming of the controller 18 DL10-0400 Preventive maintenance Preventive maintenance Executive of equipment inspection according to maintenance plan 14, 18 DL20-0200 Calibration services Calibration temperature incl. certificate including certificate, one measuring point in center of chamber at specified temperature DL30-0101 Temperature measurement 18 including certificate, 18 at specified temperature DL30-0118 Temperature measurement 27 including certificate, 27 at specified temperature DL30-0127 Temperature measurement 9 including certificate, 9 at specified temperature DL30-0109 Validation services Execution of IQ/OQ in accordance with qualification folder 15, 18, 20 DL40-0100 Execution of IQ/OQ/PQ in accordance with customer's requirement, price: on request 15, 18 DL44-0500 Qualification folder IQ/OQ supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 15, 18, 20 8012-0871 Qualification folder IQ/OQ/PQ Warranty service supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ 15, 18 8012-0959 Extension of the warranty from 2 to 3 years Extension of the warranty from 2 to 5 years beginning with the date of delivery, wearing parts are not included DL01-7041 beginning with the date of delivery, wearing parts are not included DL01-7042 * Notes See last page Page 4 / 5

NOTES 01 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge. 02 UL mark is not granted when this option is used. 03 Heat resistant only to max. 200 C. 04 Only available on units rated for 230 V. 06 Heating-up time may increase as a result of the lower heat conductivity. 07 The additional heat input may affect the temperature behavior. 09 Not in conjunction with the optional access port, door with window and interior lighting. 10 Not available on 23-liter units. 11 Not available on 23- or 53-liter units. 12 Only available on units rated for 230 V or 400 V. 13 Installation and connections take place at unit location; transport within the company only upon consultation. 14 We recommend a BINDER service contract to cover unit inspections, calibrations and validations. 15 OQ according to Yellow Paper = completed factory validation documentation of all OQ checklists. 16 Sensor calibration is performed in an accredited calibration laboratory. 17 Calibration is performed according to the BINDER factory standard. 18 Quoted prices do not include travel costs. Please refer to the chapter on BINDER Service for travel costs for your region. Quoted prices for services performed in Switzerland do not include a country-specific added fee (available on request). 19 For additional accessories, refer to the Process documentation chapter. 20 When ordering IQ/OQ qualification folders and associated IQ/OQ execution on one order, we offer a 15 % discount for the item of the IQ/OQ folder. When ordering IQ/OQ/PQ qualification folders and associated IQ/OQ/PQ execution on one order, we offer a 15 % discount for the item of the IQ/OQ/PQ folder. Page 5 / 5