NEW INSIGHTS. NEW DISCOVERIES. Real-time automated measurements of cell health, movement and function inside your incubator.

Similar documents
NEW INSIGHTS. NEW DISCOVERIES. Real-time automated measurements of cell health, movement and function inside your incubator.

Cell Health and Viability Assays Real-time automated measurements of cell health and viability inside your incubator

Live-Cell Analysis Inside Your Incubator IncuCyte S3 Live-Cell Analysis System

Why Doing Live-Cell Imaging?

Label-free, real-time live-cell assays for spheroids: IncuCyte bright-field analysis

Assays for Neuroscience Research IncuCyte S3 Live-Cell Analysis System for Neuroscience

Assays for Neuroscience Research IncuCyte S3 Live-Cell Analysis System for Neuroscience

Kinetic measurement of cytotoxicity using CellTox Green Cytotoxicity Assay on the IncuCyte TM FLR or ZOOM

IncuCyte Phagocytosis Assay

IncuCyte phrodo Red Phagocytosis Assay

IncuCyte Phagocytosis Assay

You ll never look at cells the same way again.

Fluorescent cell-labeling strategies for IncuCyte live-cell analysis Why? What? And when?

Quantification of Cell Migration and Invasion Using the IncuCyte Chemotaxis Assay

Quantification of Cell Migration and Invasion Using the IncuCyte Chemotaxis Assay

The BioFlux 200 System Using Well Plate Microfluidics for Live Cell Assays Product Overview and Tutorial

CellPlayer HT-1080 NucLight Red

MetaXpress High-Content Image Acquisition and Analysis Software

CellPlayer A549 NucLight Green

A step forward in quantitative phase imaging

IncuCyte S3 Neuronal Activity Assay

IncuCyte S3 Neuronal Activity Assay

What is the Livecyte system?

MetaXpress High-Content Image Acquisition and Analysis Software

CellPlayer HUVEC NucLight Green

IncuCyte CytoLight Green (Lenti, EF-1 alpha, puro)

Brightfield and Fluorescence Imaging using 3D PrimeSurface Ultra-Low Attachment Microplates

Multiplex Fluorescence Assays for Adherence Cells without Trypsinization

CloneSelect Imager. Objective, quantitative assessment of cell growth. Genetix Now part of Molecular Devices.

Real-time 96-well antibody internalization assays using IncuCyte FabFluor Red Antibody Labeling Reagent

xcelligence Immunotherapy Kit - Liquid Tumor Killing Assay (anti-cd71) ASSAY MANUAL

BEST PRACTICES FOR CELL CULTURE CONFLUENCY CALCULATION WITH INCELLIS

Smart Cell Monitoring

Tube Formation Assays in µ-slide Angiogenesis. 1. General Information. Application Note 19

xcelligence Immunotherapy Kit - B Cell Killing Assay ASSAY MANUAL

Accurate and Automated cell confluence assessment in microplates

WHEN MULTIMODE MEETS IMAGING YOU GAIN A WHOLE NEW PERSPECTIVE. EnSight Multimode Plate Reader

Performing Bioenergetic Analysis:

High Throughput Suspension Cell and Bead Analysis. Intellicyt ique Screener PLUS

CellPlayer CytoLight Green (Lenti, CMV, no selection)

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Direct Cell Counting Assays for Immuno Therapy

Part Number: GY-SMPE010. Smart PEI. Instructions for Use. For research use only. Not for use in humans.

Avalanche -Everyday Transfection Reagent

Break the 3D barrier CORNING 3D CELL CULTURE

Cell Processing Workstation. In Situ Laser-Mediated Cell Purification and Processing

IncuCyte Live-Cell Immunocytochemistry Assay

CellPlayer NucLight Red (Lenti, EF-1 alpha, puro)

Measuring Wound Healing and Cell Migration using Celigo Imaging Cytometer

mirrorball accelerating antibody discovery

Fluent Laboratory Automation Workstation for cell-based assays THE SIMPLE WAY TO TAKE THE COMPLEXITY OUT OF CELL BIOLOGY RESEARCH

Embrace the Future of Electrophoresis

Avalanche -Omni Transfection Reagent

Your Power for Health. Magnetic cell culturing. The n3d approach

Tube Formation Assays in µ-slide Angiogenesis

The first and only fully-integrated microarray instrument for hands-free array processing

Avalanche -Everyday Transfection Reagent

Avalanche -Omni Transfection Reagent

Cell Viability Assay Kit Fluorometric Blue

Instructions. Fuse-It-siRNA. Shipping and Storage. Overview. Kit Contents. Specifications. Note: Important Guidelines

Measuring Neuronal Activity:

RayBio ApoSENSOR TM ATP Cell Viability Assay Kit

Corning Microplates for Microscopy and High Content Imaging. Improve results with microplates for high resolution cell imaging

TransIT-TKO Transfection Reagent

Using xcelligence Real-Time Cell Analysis to Monitor Immune Cell-Mediated Killing of B Cells

TransIT -Insect Transfection Reagent

SensoLyte Homogeneous AFC Caspase-8 Assay Kit *Fluorimetric*

An Automated, Cell-based Platform for the Rapid Detection of Novel Androgen Receptor Modulators

CellPlayer 96-Well Cytotoxicity Assay Lindy O Clair, Katherine Artymovich, Meagan Roddy and Daniel M. Appledorn Essen BioScience Ann Arbor, Michigan

Cell biology workflows EMPOWERED BY TECAN

TransIT -293 Transfection Reagent

Protocol. High-throughput Transfection Protocol for GoClone Reporter Assays. Tech support: Luciferase Assay System

Celigo Assays.

ab MTT Cell Proliferation Assay Kit

TransIT -Insect Transfection Reagent

Nexcelom 3D Plates for 3D Tumor Spheroid Analysis

TransIT -LT1 Transfection Reagent

Cellometer. for Cell Counting & Analysis. Brewing Yeast Wine Yeast Platelets and Other Small Cells. Image Cytometer

Transfection Reagent Protocol for MIR 2110, 2114, 2115, 2116

TransIT -LT1 Transfection Reagent

TransIT-TKO Transfection Reagent

Single-Cell. Defy the Law of Averages

Transfection Reagent INTRODUCTION SPECIFICATIONS MATERIALS. For Research Use Only. Materials Supplied. Materials required, but not supplied

Development of Novel Advanced Cell Culture Surfaces that Provide Better Cell Growth and Attachment for Cell-Based Assays

CloneSelect Imager. Objective, quantitative assessment of cell growth

Calcein AM Cell Viability Kit

Protocol for the Co-culture of ipsc-derived Microglia with ipsc-derived Cerebral Cortical Neural Culture

INTERFERin sirna transfection reagent

TransIT-X2 Dynamic Delivery System

Cell Viability Assay Kit Fluorometric Near InfraRed

CytoMate Cell culture assistant TM. Your best friend in the lab

Transfection Reagent SPECIFICATIONS MATERIALS. For Research Use Only. Materials Supplied. Materials required, but not supplied

M X 500 µl. M X 1000 µl

TransIT Transfection Reagent

DEFY THE LAW OF AVERAGES. Single-Cell Targeted Gene Expression Analysis

EarlyTox Cell Integrity Kit

MicroRNA Analysis Paired with Novel Cell Health Assays: A Complete Workflow

TransIT -CHO Transfection Kit

A legacy of innovation and discovery

Transcription:

THE NEXT GENERATION HAS ARRIVED IncuCyte S3 Live-Cell Analysis System Real-time automated measurements of cell health, movement and function inside your incubator. NEW INSIGHTS. NEW DISCOVERIES.

See what your cells are doing and when they do it with the IncuCyte S3 Live-Cell Analysis System, reagents & consumables The IncuCyte S3 is a flexible assay platform that sits inside a standard tissue culture incubator and automatically acquires and analyzes HD phase and fluorescent images of living cells, around the clock, for days, weeks, or months. With the IncuCyte, you can Ask new questions Get new answers Improve productivity Protect your cells Devise new experiments not previously possible Conduct routine monitoring and get answers to unique scientific questions with kinetic, image-based measurements Never miss a data point with real-time continuous analysis Profile cell-specific and time-dependent biological activity Visualize and validate results with images and movies Enjoy walk-away convenience as images are automatically acquired and analyzed Multiplex measurements in 96- and 384-well assay formats Accommodate multiple users and applications simultaneously Perform analysis without removing cells from the incubator or disturbing cultures Maintain cell health and morphology with non-perturbing reagent formulations What is live-cell anaysis and what are the benefits? Start with viable, living cells Traditional live-cell assays begin with living cells, but the assay process destroys the cells. With IncuCyte S3 live-cell analysis, cells are measured in situ in a physiologically relevant environment. Plus, IncuCyte reagents are non-perturbing to cell health and morphology, further reducing potential artifacts in your experiments. And then add insights derived from kinetic analysis and investigation of experimental variables Don t limit your data to a single snapshot in time. Continuous analysis ensures you don t miss a relevant response or interaction. Plus, 96-well and 384-well assay formats enable rapid optimization of experimental variables and treatment conditions, such as seeding densities, concentrations, or coatings. A And images for information-rich analysis Image-based measurements provide spatial and morphological information that not only expands the types of questions you can ask, but are also easily validated with images and movies. t C Most importantly, live-cell analysis with the IncuCyte is easy to achieve No need to disturb your cells by bringing them to the instrument, we bring the instrument to the cells. No more struggling with environmental control systems - analyze your cells for days, weeks, or even months as they sit stationary in the stable environment of your tissue culture incubator. The IncuCyte provides accessible, information-rich analysis whether you simply want to improve experimental outcomes with enhanced culture quality control, or study complex cell-cell interactions such as immune cell killing. E B D Derive deeper insights with real-time live-cell analysis. (A) Automatically acquire images over time, (B) use IncuCyte VesselView to view images of all locations in the vessel at once and quickly assess experimental results, plus zoom in on images of interest (C) automatically identify regions of interest via masks (D) generate presentation-ready timelapse graphs, and (E) view all 96- or 384-well kinetic trends at once with IncuCyte PlateGraph and export data to calculate EC50 or IC50 response values. 2

INCUCYTE S3 LIVE-CELL ANALYSIS SYSTEM View and analyze in real-time Efficient and reproducible image analysis How IncuCyte transforms research A simple, yet powerful workflow that supports your entire research team day and night Simple, flexible sample prep Application-specific processing and analysis software modules enable reproducible, quantitative analysis Define image segmentation parameters once on a sample set, then use to process multiple experiments Unique image calibration process allows for re-use of image processing parameters on experiments performed now and in the future. Powerful visualization of images and kinetic measurements View images of all locations in the vessel at once, then zoom in on images of interest with VesselView. Quickly assess trends and outliers. Visualize timecourses for an entire experiment using the PlateGraph graph areas, counts, or intensities over time in 96 or 384 wells at once Create presentation-ready graphs without using third-party software Easily compare images and metrics to draw conclusions rapidly Flexible, customizable tools developed for biologists enable publication-ready graphs of kinetic trends and effects (below). View all of your wells at once with new VesselView. SKOV-3 transduced with IncuCyte NucLight Red Lentivirus were grown in ULA U-bottom 96-well plates for 3 days then treated ± 1 µm camptothecin, showing disruption of compact spheroid. Compatible with a wide range of culture vessels and applications Monitor flasks or dishes to ensure cell health before your experiment with label-free confluence analysis Conduct a wide variety of assays in 96- and 384-well microplates, up to six at a time simultaneously Maximize efficiency with IncuCyte reagents Maintain cell health and morphology with non-perturbing reagent formulations Proprietary formulations reduce time spent selecting and troubleshooting reagents from multiple vendors that are not validated for live-cell assays Mix-and-read reagents and protocols save time no washing, no fixing, no lifting Acquire images over days or weeks Minimize disturbance of cells Cells remain in the incubator while images are acquired Unique optical design Cells remain stationary while optics move perfect for sensitive and non-adherent cell types Includes 4x, 10x, and 20x objectives and motorized turret Multiple imaging modes Acquire high quality HD phase plus red and green fluorescent images and movies Quickly select regions to image and set time lapse intervals Set up & walk away Simple and flexible experimental set up Interface guides users through set up of automated acquisition and analysis parameters Multiple users can schedule experiments using different acquisition frequencies and magnifications Guided interface enables rapid experimental set up, even for first time users (above). Track experimental conditions from setup through analysis PlateMap Editor creates a visual record of userdefined parameters including cell line, seeding density, and treatment conditions Set up the PlateMap before you initiate experiments to keep track of experimental variables automatically during acquisition and analysis Profile biological activity over time with multiple imaging channels. Neuronal network formation of icell GlutaNeurons (Cellular Dynamics International) transduced with IncuCyte NeuroLight Red Lentivirus co-cultured with astrocytes (left, middle), followed by cell apoptosis (IncuCyte Caspase-3/7 Green) and neurite disruption after treatment with 1 mm glutamate (right). Create a visual record of your parameters and track all of your experimental variables throughout your workflow. Remote, networked access Control the IncuCyte from any networked location using unlimited, free licenses for your lab or facility 3 4

Maximize productivity and efficiency IncuCyte reagents & consumables Cell Health Assays Continuously monitor proliferation, cytotoxicity, and apoptosis: Proliferation label-free or IncuCyte NucLight reagents to label nuclei for cell counts Cytotoxicity IncuCyte Cytotox reagents to detect cell death Apoptosis IncuCyte Caspase 3/7 and Annexin V reagents to detect apoptosis HT-1080 IncuCyte NucLight Red treated with 3-fold decreasing concentrations of camptothecin and imaged every 3 hours. Images were automatically masked to measure confluence, number of apoptotic cells (IncuCyte Caspase 3/7), and number of viable cells (IncuCyte Nuclight Red Lentivirus) over time. Migration & Invasion Assays Innovative solutions for studying migration and invasion IncuCyte Scratch Wound Assay Unique WoundMaker 96-pin tool creates 96 precise, uniform cell-free zones with the touch of a button. Visualize and analyze wound closure in real-time in ImageLock plates. ClearView Chemotaxis Plate Achieve real-time visualization of chemotaxis in a 96- well format. Our proprietary ClearView chemotaxis plates combine the optical clarity of microfluidics devices with the throughput of transwell assays. Find more IncuCyte reagents & consumables at essenbio.com/reagents 5

Ordering information Contact us at sales@essenbio.com to place an order or for more information. PRODUCT DESCRIPTION CAT. NO. IncuCyte S3 Live-Cell Analysis System Includes image acquisition and analysis system with: 4x, 10x, and 20x objectives Controller with 16.4 TB storage Unlimited software licenses for standard acquisition and basic analyzer (additional modules are required for certain applications) 4647 IncuStore S Storage Unit Additional 32.7 TB storage for IncuCyte S3 4689 Cell Health See what you can do with the IncuCyte System Learn more at www.essenbioscience.com/applications Apoptosis Detect apoptosis in living cells and in real time using simple mix-and-read protocols. Cytotoxicity Measure real-time cell viability with simple mix-and-read protocols suitable for screening. Proliferation Automatically measure label-free growth or count living cells with NucLight nuclear labeling in real time. Neurite Analysis Measure neurite dynamics automatically and in real-time in neuronal monocultures and co-cultures with astrocytes. Tumor Spheroids Track and quantify tumor spheroid formation, growth and shrinkage in real time. Learn more at www.essenbioscience.com or contact us at Sales@essenbio.com Migration & Invasion Scratch Wound Migration and Invasion Investigate treatment effects on cell migration across a 2D substrate or invasion through a 3D gel matrix. Chemotaxis Visually confirm chemotactic migration or invasion towards chemoattractants with ClearView 96-well plates. Cell Function Immune Cell Clustering Visualize and quantify expansion and clustering without removing your cultures from the incubator. Immune Cell Killing Detect tumor cell death directly by counting NucLight nuclearlabeled cells or measuring apoptosis with IncuCyte Caspase 3/7 reagent. Phagocytosis Continuously analyze and generate movies of phagocytes engulfing phrodo labeled bioparticles or target cells. Angiogenesis Kinetically measure vascular tube formation using our complete co-culture assay kit. Cell Monitoring and Other Workflows Stem Cell Monitoring and Reprogramming Monitor stem cell reprogramming and differentiation events without removing cells from the incubator. Cell Culture QC Monitor cell morphology and proliferation label-free and without removing cells from the incubator. Dilution Cloning Automatically scan for clones and verify monoclonality with whole well analysis. Transfection Efficiency Monitor and quantify the efficiency and timecourse of gene transfection using GFP/RFP constructs. Reporter Genes Measure activity of any promoter driven recombinant GFP/RFP reporter gene expression in real time. View over 1,000 publications at essenbioscience.com/publications and see how IncuCyte is enabling science. 2017 Essen BioScience. All rights reserved. IncuCyte, Essen BioScience and all names of Essen BioScience products are registered trademarks and the property of Essen BioScience unless otherwise specified. 6 8000-0333-F00