FLAMABILITY TESTS FOR ELECTRICAL CABLES

Similar documents
Proposal for the 03 series of amendments to UN Regulation No. 118 (Burning behaviour)

SFI SPECIFICATION 56.1 EFFECTIVE: FEBRUARY 26, 2014 * PRODUCT: NASCAR Dashboard and Other Carbon Fiber Components

Guidance on Registration System for Components and Materials used in Electrical Appliances (CMJ) and Guide for Application for Registration

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018

ASTM E Fire Tests of Building Construction and Materials* Protective Structures, Ltd. Bullet-Resistant FRP Panel

Test Summaries: AWP 1818 & 3030

Caledonian Cables Ltd

A NEW APPARATUS FOR FLAME SPREAD EXPERIMENTS

Content HYBRID AND SPECIAL CABLES G 2 NEW NEW NEW NEW. page. Applications... G/3. Construction examples of special cables

Box sealing system DS 90

ADC. The Greenbook of Flex. Flexible Duct Performance & Installation Standards (5 th Edition) Characteristics of flexible duct

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. TB/T Translated English of Chinese Standard: TB/T1484.

according to UL AWM 758, Style and based on EN resp. VDE

Accreditation Scope by Certification Test Order

Document No. Rev Standard test methods for Nolato materials 4 Prepared by Checked Date Page Karin Sundberg Magnus Mattsson (8)

WSD 1800 Issue C Rated Ford Automotive Sensor Cable Specification

U.V resistance UL Sunlight Resistance. Flame retardant IEC

Content. PV1-F Halogen-free cable for photo-voltaic systems... G/11. PV1-F dual Halogen-free twin cable for photo-voltaic systems...

Recent Considerations of New UL1703 Method. Dwayne Sloan

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: December 18, 2012 REVISED DATE:

SPECIFICATION FOR FUSE DISTRIBUTION BOARD FOR COACHES. Revision

SpotClip. Downlight covers for safe lighting installation in suspended ceilings

ASSESSMENT REPORT. EWFA Report No: Report Sponsor: 3M New Zealand 94 Apollo Drive, Rosedale Auckland, New Zealand

6A V CVQ cable (C rank)

TEST REPORT. Acoustical Surfaces, Inc. ASTM E84-04 SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS. We Identify and S.T.O.P. Your Noise Problem

Product overview. Product characteristics. Article number Cables - Universal Print Date

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: March 13, 2017 REVISED DATE:

Hose protection. Hose protection. Edition: 02/2008 Catalogue 1

FP30112WHITE100 Heat Shrink TW Tubing 100' Spool

HELUKABEL CC-Link Certified Cables

REPORT NUMBER: SAT-002A ORIGINAL ISSUE DATE: August 16, 2017 REVISED DATE:

Exterior Wall Systems NFPA 285

Nairobi Funeral Home and Forensics INCINERATOR BILLS OF QUANTITIES

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

FLAME RETARDED. By VAMP TECH

Highly flexible control cable with PVC core insulation and PVC sheath - certified for North America

1:100 GABION WALLS LEGEND NOT FOR CONSTRUCTION TYPICAL DRAWING TEXT SETTING TYPE CHARACTER HEIGHT PEN SETUP FOR PLOTTING SUBTITLE

Page No 1 Introduction... 3

ABRASION PROTECTION ELECTRICAL SOLUTIONS

INDUSTRIAL TEXTILE, INSULATION PACKINGS AND INSULATION MILLBOARD

SRI LANKA STANDARD SPECIFICATION FOR THREE-PIN PLUGS, SOCKET-OUTLETS AND SOCKET-OUTLET ADAPTORS

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: March 13, 2013 REVISED DATE:

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

ASTM E84-05 SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS

SpotClip. Downlight covers for safe lighting installation in suspended ceilings

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: April 30, 2013 REVISED DATE:

DEVELOPMENT OF AN FST/OSU PASSING RIGID POLYURETHANE FOAM FOR THE AEROSPACE INDUSTRY

7. Experimental. 7.1 Flame retardant treatment

Exterior Wall Solutions Building Shell

UL PCB Recognition what is it & why do you need to know about it

ES2000 TUBING Environmental Sealing, Polyolefin, Semirigid, Adhesive-Lined

TECHNICAL DATA SHEET GRILON TSG-30/4 V0

Pipe Seal. A penetration seal system for thermoplastic pipes of all types and sizes up to 500 mm diameter. Prospect: KBS Pipe Seal page 1 of 6 09/12

TEST REPORT. Acoustical Surfaces, Inc. ASTM E84-03 SURFACE BURNING CHARACTERISTICS. We Identify and S.T.O.P. Your Noise Problems

Project comparison: old system. One-to-one fixture replacement without changing the existing electrical system

WSD 2038 Issue 4. Specification for ZHSCG-35, Halogen-free, Power Cables for use in Photovoltaic Applications

Report on First Revision June 2014 NFPA 5000

The experimental programme for this stage of the project has been undertaken in three phases:

HELUKABEL CC-Link Certified Cables

TEST REPORT. Acoustical Surfaces, Inc. ASTM E84-04 SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS. We Identify and S.T.O.P. Your Noise Problem

Data sheet chainflex CF887

REPORT NUMBER: SAT-004A ORIGINAL ISSUE DATE: April 13, 2017 REVISED DATE:

Type 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn

FieldLink for PROFIBUS Applications

Data sheet chainflex CFSPECIAL.182

DECLARATION OF PERFORMANCE

IAS Accreditation Number ELTEK International Laboratories

Content. Festoon 715 P PUR cable for flexible application in festoon systems... G/21

PRODUCT SUSPENDED. Rainscreen Cladding Compliance Guide When specifying Celotex RS5000 in buildings above 18 metres

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

Flammability and Moisture absorption test of rigid polyurethane foam

DELIVERING THE FUTURE OF COMPOSITE SOLUTIONS CIVIL & ARCHITECTURAL FIRE REQUIREMENTS APPLIED TO COMPOSITE STRUCTURES.

Shipping Container R&D Test Plan

Flexible Air Duct and Flexible Air Connectors Installation and Energy Use

SPECIFICATION FOR FRLS POWER CABLES

DATA SHEET Single Core 2HR Fire Rated Cable

SPECIFICATION CONTROL DRAWING

OMEGA KFH SERIES. Fast Delivery! PRE-WIRED STRAIN GAGES. Proven Omega Quality Strain Gages with Two or Three Wires Attached to Make Installation Easy!

180mm Conveyor System

NTechnical Data. General Information - C... N/2. General Information - PUR... N/3. General Information - PVC... N/4

Construction guideline

Roofing and Cladding. ALTERNA NT-slate APPLICATION INSTRUCTIONS 11

Assessment of the Fire Behaviour of Insulated Steel Deck Flat Roofs

USER S MANUAL release 1.0

SafeX110 Single Core Flexible Tinned Copper Cable

NTechnical Data. General Information - C... N/2. General Information - PUR... N/3. General Information - PVC... N/4

F = Polyethylene R = Fire Resistant Polyethylene FR = Flame Retardant Polyethylene N = Nylon Q = 25' L = 50' C = 100' 50 = 1/2"

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

3M Scotch-Weld TM 3450 FST Void Filler

DECLARATION OF PERFORMANCE

THERMOFIT AP2000 TUBING HEAT-SHRINKABLE CROSSLINKED MODIFIED POLYOLEFIN, ADHESIVE LINER

WLC60 Heavy Duty LED Light

WLB32 Industrial LED Light Bar (DC)

Fire Resistant Cable (FRC) Flexible Fireproof Cable (FFC) Mineral Insulated Cable (MIC)

WALLSPAN. Insulated Panels for a Clean World

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Heatshrink & Cable Repair Solutions

Transcription:

Tests on electric and optical fibre cables under fire conditions Description E 60332-1-2 E 60332-2-2 acc. to IEC 60332-1-2 acc. to IEC 60332-2-2 Tests for flame Tests for flame propagation for a single insulated propagation for a single small insulated wire or cable - procedure for wire or cable - procedure for 1-kW pre-mixed flame diffusion flame 600 mm 600 mm acc. to IEC 60332-1-1 acc. to IEC 60332-2-1 1 kw flame defined by the stipulated setting of the flame length 45 to specimen 45 to specimen Duration of flame see table 1 20 seconds Cable must be self-extinguishing. Cable must be self-extinguishing. The damage or carbonization may The damage or carbonization may only reach max. 50 mm under the only reach max. 50 mm under the upper fixing clamp. upper fixing clamp. Table 1 outer diameter *) of specimen in mm in seconds D 25 60 25 < D 50 120 50 < D 75 240 D > 75 480 *) If cables or insulated cables are tested that are not round (e.g. flat twin cables) their dimensions is to be measured and an equivalent diameter must be calculated from this. 18

Examination of the flame length of extended bundle of wires and insulated cables Description IEC 60332-3-..., E 60332-3-... 3500 mm Flat burner (Ribbon gas burner of American Gas Furnace Co.) defined by stipulated flow of gas and air horizontal Category A, B: 40 minutes Category C, D: 20 minutes The burned portion of the sample must not be longer than 2.5 m measured from the bottom edge of the burner, as far as not otherwise specified in the relevant standards. E 60332- IEC 60332- Category A 7,0 l/m 3-22 3-22 Category B 3,5 l/m 3-23 3-23 Category C 1,5 l/m > 12 mm cable-ø 3-24 3-24 Category D 0,5 l/m 12 mm cable-ø 3-25 3-25 Volume percent of non metallic material per meter. max. width (acc. to testing methods) 19

Description UL 1581 section 1080 - reference to standard UL 2556, section 9.4 (VW-1 Flame Test) 610 mm Bunsen burner with additional air supply (Tirril gas burner) ø 9.5 mm 500 W flame 20 to specimen 5 x 15 seconds with at least 15 seconds flaming break Paper max. 25% carbonized. The specimen may keep on burning for max. 1 minute after any application. Material dropping must not ignite the cotton (B) lying under the specimen. papier 12.5 x 20 mm 230-240 mm 180 mm 610 mm length of specimen 254 mm 20 B 20

Description UL 1581 section 1061 (Cable Flame Test) 455 mm Bunsen burner with additional air supply (Tirril gas burner) ø 9.5 mm 500 W flame 20 to specimen 3 x 60 seconds with 30 seconds between each flaming Paper max. 25% carbonized. The specimen may keep on burning for max. 1 minute after the last application. Material dropping must not ignite the cotton (B) lying under the specimen. papier 10 x 20 mm 230-240 mm 50-75 mm 455 mm length of specimen 250 mm 20 B 21

Description UL 1581 section 1060 (Vertical Flame and FT1 Test) 45-610 mm Bunsen burner with additional air supply (Tirril gas burner) ø 9.5 mm 500 W flame 20 to specimen 5 x 15 seconds with each 15 seconds flaming break Paper max. 25% carbonized. The specimen may keep on burning for max. 1 minute after the last application. papier 12.5 x 20 mm 230-240 mm 180 mm 254 mm 457-610 mm length of specimen 20 22

Description F C 32-070»C1«1600 mm +830 C ±50 C in the chimney Duration of test 30 minutes The outstanding cable above the chimney may not be damaged. ventilator 1600 mm min. 250 mm 800 mm 30 mm air air 23