GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS

Similar documents
GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS

TOWER & ANTENNA Product Catalog

Tower & Antenna Product Catalog

FIBERLIGN Dielectric Dead-end

MSME Testing Centre, 65/1, G. S. T. Road, Guindy, Chennai, Tamil Nadu. Discipline Electrical Testing Issue Date

TS 804 CABLES TABLE OF CONTENTS TRAFFIC SIGNAL EQUIPMENT POLE WIRING DIAGRAM LOCATIONS WITH CENTRE MEDIANS

Power Systems 2 ELE3015. Lecture 1: Transmission Lines

CONSTRUCTION SPECIFICATION FOR POLE ERECTION

04.00 GENERAL SECONDARIES & SERVICES SECONDARY AND SERVICE CABLE SPLICES INSULATED SERVICE ENTRANCE COMPRESSION CONNECTORS 04.

Practical Checklists of Best Practices Frank Donovan, W3LPL

SECTION 4 - SECONDARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS


Tower Site Inspection Procedures

Index GROUNDING CONNECTORS. TYPE WB Ground Rod Clamps. TYPE G/SRC Ground Rod Clamps. Heavy-Duty Clamps. Standard-Duty Clamps (Universal)

Telecom/ Datacom Tools

OVERHEAD SERVICES - SECONDARY

80M 4-Square. An antenna project to obtain a bigger signal on the 80 Meter (3.5 to 3.8 MHz) amateur radio band. Bruce Whitney W8RA

NEW Items. Wire Rope and Accessories. Eye Nuts, Bolts and Turnbuckles. Roller Chain. kent-automotive.com NI1

SECTION PARK NON-SEGREGATED BUS SPECIFICATION

TS 805 POLES TTS CONSTRUCTION SPECIFICATION FOR POLE INSTALLATION TTS MATERIAL SPECIFICATION FOR STEEL POLES BASE MOUNTED

STANDARD TECHNIQUE : OH4L/1

New Construction Units. a. Includes the furnishing of all labor and equipment for the installation of new construction units.

SECTION 410 FENCES All materials shall be new and without flaws or defects of any type GENERAL

SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS

CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION

TEMPORARY FACILITIES

ANTI RAM SECURITY CHAIN LINK FENCE - 4, MPH SECTION

Phone: Fax:

COMMERCIAL ITEM DESCRIPTION SLING, PALLET

REA LISTED. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.

CONSTRUCTION SPECIFICATION FOR POLE ERECTION

SECTION GROUNDING AND BONDING

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

600 GROUNDING 9/12/2018

CONSTRUCTION SPECIFICATION FOR ERECTION OF POLES

SECTION DECORATIVE METAL RAILINGS

CONSTRUCTION SPECIFICATION FOR ERECTION OF POLES

A. Product Data shall be provided for each type of product indicated.

Fall Protection Catalogue CANADIAN

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

Hilti Cable Transit System. More safety on board. Hilti. Outperform. Outlast.

SECTION CHAIN-LINK FENCES AND GATES 02821/1

Keuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.

STANDARD FLAT LOAD CELLS

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF POLES

OVERHEAD SERVICES - RESIDENTIAL & GENERAL SERVICE. See Chapter 3, Section 3.01 for more information about point of entrance (POE).

Electric Service Handbook

05510: TAPERED STEEL TROLLEY POLES AND ACCESSORIES

SPECIFICATION & DESIGN MANUAL " AISI 1060 to 1065 Rockwell Hardness 51 to 55 Perma-Seal coated Stick-E Pin 3/4" (Step Shank) 1"

AR SCAFFOLDING AR ALUMINUM MOBILE AR STEEL MOBILE

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY OF MISSOURI Electrical Manholes and Handholes 2016 Q1

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11

Commercial Electric Policy

OVERHEAD SERVICE. Table of Contents - Section 400

Rack Guard Safety. Industrial. InCord incord.com

PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES

SECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Shackles. Applications. Range. Design. CAD drawings. Finish

5 / 8" AFL NO. ULTIMATE STRENGTH (LBS.) APPROX. WEIGHT EACH (LBS.) APPLICATION SCE , HIBUS Double Suspension R1"

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

SPECIAL SPECIFICATION 1924 Neighborhood Friendly High Mast Illumination System

PART 7 COMMUNICATIONS, LIGHTING, TRAFFIC CONTROL, POWER

Student Services & Classroom Addition

ASQ-10. Ten Meter Squalo INSTRUCTION MANUAL. CAUTION: Read All Instructions Before Operating Equipment. Cushcraft. Amateur Radio Antennas

SECTION ACOUSTICAL PANEL CEILINGS

Fig. 1 - Standard Clevis Hanger

Overhead Smart Conductors

ITEM 555 CHAIN LINK FENCING

Transmission Line General Requirements Including Typical Overhead Line Structures. Document Number: 1-03-FR-09

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

TEMPORARY PROTECTIVE GROUNDING EQUIPMENT

A. This section is intended to provide design guidelines for Utility Direct Buried Piping and Conduit Systems.

DEADENDS AND SPLICES. Catalog CA12004E

B. ASTM A 153/A 153M - Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware; 1998.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

The Market Leader: Yesterday Today and Tomorrow Shackles THE COMPETITION

TITEN HD Heavy Duty Screw Anchor for Concrete & Masonry

SECTION ORNAMENTAL ALUMINUM RAILING

Kaf-Tech Product Specification

DBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE

(Condensed from National Electric Code)

SECTION CHAIN LINK FENCES AND GATES

SPECIFICATION FOR FRLS POWER CABLES

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

Solutions Railing Overview ACTUAL FREIGHT CHARGES APPLY TO ALL SOLUTIONS RAIL ORDERS

KD ANGLE LEG GUYED TOWER McIntosh, ON Report No: 9999 TOWER INSPECTION REPORT

12/21/2018 WHAT S NEW SINCE What's New Since SPEC BOOK 2018 SPEC BOOK 2018 SPEC BOOK WHAT S NEW SINCE 2014

TABLE OF CONTENTS. Page FOREWORD INTRODUCTION SCOPE NORMATIVE REFERENCES

RESIDENTIAL QUICK REFERENCE

SECTION 2831 ITEM F-162 CHAIN-LINK FENCES

TECHNICAL SPECIFICATIONS LAYING OF DIFFERENT WIRES & CABLES MOUNTED ON POLES FOR BRPL/BYPL

CHAIN LINK FENCES AND GATES

SECTION CHAIN LINK FENCES AND GATES

CONSTRUCTION SPECIFICATION FOR GROUNDING

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

Series IEEE 1070 ERS

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

Transcription:

GUY-GRIP Dead-end NOMENCLATURE Please visit our web site at www.preformed.com for additional literature.guy-grip Dead-end Application Procedure - SP2045 Cross-over Marks: (A) Indicate starting point for application on smaller diameter fittings. (B) Indicates alternate starting point for application on larger diameter fittings. Cabled Loop: Furnished as standard, all sizes. Pitch : One complete wrap. and : Assists in identifying the strand size, corresponding to tabular information appearing on catalog pages. Identification Tape: Shows catalog number, nominal sizes. Short Leg-Long Leg: Identifies rods belonging to each leg, after application. During application, the short leg should be applied first. GENERAL INFORMATION GUY-GRIP Dead-ends are intended for use on single wood poles associated with distribution construction. GUY-GRIP Dead-ends were not designed or tested for use on overhead shield wires and not intended for that application. Refer to Big-Grip Dead-end, an alternate product recommended for guying transmission construction, or tower and antenna applications. Refer to the Installation Tools section for the PREFORMED Pulling Eye, designed to assist application at the anchor. RATED HOLDING STRENGTH: GUY-GRIP Dead-ends are rated at 100% of the strand's published rated breaking strength. MATERIAL SELECTION: GUY-GRIP Dead-ends are made of the same basic material as the strand to which they are applied. This pertains to galvanized, *Bezinal, **Copperweld, Aluminum clad steel, stainless Type 302, and stainless Type 316. Any of these materials can be selected from the catalog tables. The recommended types of strand are also indicated. TAPPING: GUY-GRIP Dead-ends are mechanical devices not designed as current transfer connectors. Consequently, tapping is not recommended over or through the GUY-GRIP Dead-end. APPLICATION-INSPECTION: Within the first 3 months after initial application, GUY-GRIP Dead-ends may be removed and reapplied two times after initial application for the purpose of retensioning the guy. After 3 months, a new dead-end should be used any time removal is required. GUY-GRIP Dead-ends should be used on hardware that is held in a fixed position; the fitting should not be allowed to rotate or spin about the axis of the strand. They should not be used as tools, that is, come-alongs, pulling-in grips, etc. Lay direction of both the GUY-GRIP Dead-ends and the strand should be the same. Most strand is left-hand lay. STRAND TAIL: For appearance and safety the strand tail should be cut as close as convenient to the crossover mark and buried inside the crossover mark if possible. If desired, the strand tail can, instead, extend through the loop for grounding purposes. Any tail over 2" or 3" should be restrained and not permitted to rotate during loading of the guy. SAFETY CONSIDERATIONS 1-20 1. This product is intended for a single (one-time, permanent) use and for the specified application, although it may be reapplied twice for retensioning within 90 days of initial installation. CAUTION: DO NOT MODIFY OR REUSE THIS PRODUCT AFTER 90 DAYS UNDER ANY CIRCUMSTANCES. 2. This product SHOULD NOT be used as a tool; that is as a come-along, pulling in grips, temporary bracing, etc. 3. This product is intended for use by trained craftspeople only. This product SHOULD NOT BE USED by anyone who is not familiar with and trained in the use of it. 4. When working in the area of energized lines with this product, EXTRA CARE should be taken to prevent accidental electrical contact. 4. For PROPER PERFORMANCE AND PERSONAL SAFETY be sure to select the proper size GUY-GRIP Dead-end before application. 5. GUY-GRIP Dead-ends are precision devices. To insure proper performance, they should be stored in cartons under cover and handled carefully. *Bezinal is a registered trademark of the Bekaert Corporation. **Copperweld is a registered trademark of the Copperweld Co.

GUY-GRIP Dead-end HARDWARE CONSIDERATIONS CABLED LOOP: Anchor eyes and other fittings need groove diameters only slightly larger than the strand because the diameter of the cabled rods of GUY-GRIP Dead-ends approximates strand diameter. Cabled loops are designed for a variety of fittings with dimensions shown in the table below. Suggested hardware dimensions for cabled-loop GUY-GRIP Dead-ends Tower Products, Dead-end and Dead-end Accessories: Section 1 GUY-GRIP Dead-end DEAD-END DIAMETER RANGE (INCHES) Min. Max. NOMINAL STRAND SIZES GALVANIZED STEEL ALUMINUM- CLAD STEEL Min. seat diameter with dead-end at first cross-over mark. * Depending on geometric shape of the hole, a hole diameter less than specified may be acceptable. ** Use Big-Grip Dead-ends. Guying of transmission structures and metal towers require Big-Grip Dead-ends, VARI-GRIP Dead-ends. SEAT DIMENSIONS (figures 1 & 2) (in.) Max. seat diameter with dead-end at first cross over mark. Max. seat diameter with dead-end at second cross-over mark. MINIMUM GROOVE DIAMETER (in.) (fig. 2) MINIMUM HOLE DIAMETER* (in.) (fig. 3).123.143 1/8 3/4 1-3/4-3/16 1/4.144.173 5/32 3/4 1-3/4 2-1/2 1/4 5/16.174.203 3/16 1-0 1-3/4 2-1/2 1/4 3/8.204.230 7/32 3 #10, 4M3 1-1/8 1-3/4 2-1/2 5/16 3/8.231 1/4 7 #12, 6M 1-1/8 1-3/4 2-1/2 5/16 7/16.260.291 9/32 7 #11, 8M 1-1/8 1-3/4 2-1/2 3/8 1/2.292.336 5/16 7 #10, 10M 1-1/4 1-3/4 2-1/2 3/8 9/16.337.394 3/8 7 #8, 14M, 16M 1-3/8 1-3/4 2-1/2 7/16 5/8.395.474 7/16 7 #7, 18M, 20M 1-3/8 2-3/8 2-1/2 1/2 11/16.475.515 ** 7 #6 1-3/8 2-3/8 9/16 3/4.516.570 ** 7 #5, 25M 1-1/2 2-5/8 5/8 15/16 ACCEPTABLE FITTINGS A NCHOR RODS THIMBLE EYE-BOLTS, -EYENUTS & EYES POLE FITTINGS GUY-STRAIN INSULATORS ANSI 54-1 54-2 54-3 54-4 CAUTION: Hardware of this type is not normally acceptable because fatigue life of GUY-GRIP Dead-ends could be substantially reduced. Heavy-Duty-Type Cable Thimbles, if used, can collapse when guy tensions are high. If thimbles are used in the loop of the GUY-GRIP Dead-end, a large pin is recommended to fill the loop of the thimble to prevent distortion. The collapsing strength of the thimble and the proper pin size should be obtained from the thimble manufacturer. 1-21

GUY-GRIP Dead-end: Galvanized Steel Extra High Strength, High Strength, Siemens Martin, Utilities Grade3 GDE-1102 3/16 B-coat Strand Units Wt./Lbs. (inches) Construction Per Carton.186.195 100 30 20 Red GDE-1103 7/32.216 50 19 24 Green GDE-1104 1/4.240 50 24 25 Yellow GDE-1105 9/32.279 50 26 28 Blue GDE-1106 5/16 GDE-1107 3/8.327 50 39 31 Black 50 51 35 Orange GDE-1108 7/16.435 25 40 38 Green C-coat Strand Units Wt./Lbs. (inches) Construction Per Carton GDE-2102 3/16.186 100 30 20 Red.195 GDE-2103 7/32.216 50 19 24 Green GDE-2104 1/4.240 50 24 25 Yellow GDE-2105 9/32.279 50 26 28 Blue GDE-2106 5/16 GDE-2107 3/8.327 50 39 31 Black 50 51 35 Orange GDE-2108 7/16.435 25 40 38 Green Left-hand lay is standard. (3) Rated holding strength is 100% of published rating for all grades of galvanized strand. (4) Consult PLP for sizes and stranding not shown. 1-22

GUY-GRIP Dead-end: Bezinal Bezinal Strand 2 (inches) BDE-9102 3/16 BDE-9104 1/4 BDE-9106 5/16 BDE-9107 3/8 Strand Units Wt./Lbs. Construction.186.195.240.327 Tower Products, Dead-end and Dead-end Accessories: Section 1 Per Carton 100 30 20 Red 50 24 25 Yellow 50 39 31 Black 50 51 35 Orange BDE-9108 7/16.435 25 41 38 Green GUY-GRIP Dead-end Left-hand lay is standard. (2) Rating holding strength is 100% of the published rating for the strand. (3) Dead-ends are manufactured from Bezinal material or common 95% ZN-5% AL-Mischmetal Alloy produced to ASTM- B750. Bezinal is a registered trademark of the Bekaert Company. 1-23

GUY-GRIP Dead-end: Aluminum Clad Aluminum Clad Steel Strand 4 Nominal Strand Left-Hand Lay is standard. (3) Refer to General Information for material selection. (4) Rating holding strength is 100% of the published rating for the strand. (5) Consult PLP for sizes and stranding not shown. Units Wt./Lbs. Per Carton AWDE-4102.174 3 # 12 100 21 18 Orange AWDE-4108 AWDE-4110 AWDE-4113 AWDE-4116.220.220.247.242.277.272.311.306.306 4M 3 # 10 3 # 9 6M 3 # 8 8M 3 # 7 10M 5/16" - 7 # 10 50 20 21 Green 50 20 24 Yellow 50 22 24 Blue 50 29 26 Black AWDE-4118.330 11.5M 50 30 26 Green AWDE-4119.349.343.343 3 # 6 12.5M 11/32" - 7 # 9 50 41 29 Yellow AWDE-4120.363 14M 50 53 31 Blue AWDE-4122.392.385.386 3 # 5 3/8" - 7 # 8 16M 50 55 32 Orange AWDE-4124.417 18M 25 37 34 Black AWDE-4125.433 7/16" - 7 # 7 25 40 36 Green AWDE-4126.444 20M 10 22 37 Yellow AWDE-4128.486 1/2" - 7 # 6 10 23 39 Blue AWDE-4130.519 25M 10 31 43 Red AWDE-4131.546 7 # 5 10 32 44 Yellow 1-24

GUY-GRIP Dead-end: Aluminized Aluminized Strand 4 Tower Products, Dead-end and Dead-end Accessories: Section 1 GUY-GRIP Dead-end (inches) AZDE-7100 3/16 AZDE-7102 1/4 Strand Units Wt./Lbs. Construction Per Carton.186.195.240 100 25 18 Red 50 22 23 Yellow AZDE-7103 9/32.279 50 27 24 Blue AZDE-7104 5/16 AZDE-7106 3/8.327 50 37 27 Black 50 63 32 Orange AZDE-7107 7/16.435 25 45 34 Green Left-Hand Lay is standard. (3) Refer to General Information for material selection. (4) Rating holding strength is 100% of the published rating for the strand. (5) Consult PLP for sizes and stranding not shown. 1-25

GUY-GRIP Dead-end: Copperweld Copperweld Strand 4 Nominal Strand Units Wt./Lbs. Per Carton CDE-8100.164 2.2M 100 19 17 Orange CDE-8102.174 3 # 12 100 24 17 Red CDE-8106.209 4M 100 32 18 White CDE-3101.220 3 # 10 100 44 20 Green CDE-3103.247.237 3 # 9 6M 50 24 21 Yellow CDE-3104.258 6M3 50 25 22 White CDE-3106 CDE-3109 CDE-3112.276.277.303.306.311.343.345.349 8M 3 # 8 10M 7 # 10-5/16" 3 # 7 7 # 9-11/32 12.5M 3 # 6 50 26 23 Blue 50 34 25 Red 50 46 27 Green CDE-3113 14M 50 64 30 Blue CDE-3115.385.386.392 7 # 8-3/8 16M 3 # 5 50 65 31 White CDE-3117.414 18M 25 46 34 Orange CDE-3118.438.433 20M 7 # 7-7/16 25 47 35 Yellow CDE-3121.486 7 # 6-1/2 25 65 39 Blue CDE-3123.525 25M 10 37 43 Green CDE-3124.546 7 # 5-9/16 10 38 44 Yellow Left-Hand Lay is standard. (3) Refer to General Information for material selection. (4) Rated holding strength is 100% of the published rating of the strand. (5) Consult PLP for sizes and stranding not shown. (6) Copperweld is a registered trademark of the Copperweld Co. 1-26

GUY-GRIP Dead-end: Stainless Steel Type 302 and Type 430 Strand Tower Products, Dead-end and Dead-end Accessories: Section 1 GUY-GRIP Dead-end Type 302 Strand Units Wt./ Lbs. Percent of Strands Rated Breaking Strength (inches) Construction Per Carton SDE-5101 7/32.224.216 100 30 22 Blue 100% SDE-5102 1/4.249 50 25 26 Yellow 100% SDE-5103 9/32.279 50 26 27 Black 90% SDE-5104 5/16 SDE-5105 3/8 Type 316 Strand 50 41 31 Orange 93% 50 66 37 Green 83% Type 316 Strand *These dead-ends utilize the open helix design. Left-Hand Lay is standard. (3) Refer to General Information for material selection. (4) Consult PLP for sizes and stranding not shown. Units Wt./ Lbs. Percent of Strands Rated Breaking Strength (inches) Construction Per Carton SDE-6101 7/32.224.216 100 30 22 Blue 100% SDE-6102 1/4.249 50 25 26 Yellow 100% SDE-6103 9/32.279 50 26 27 Black 100% SDE-6504* 5/16 SDE-6105 3/8 50 41 31 Orange 100% 50 66 37 Green 93% SDE-6107 1/2.500 10 52 53 Blue 87% 1-27