Infinity Perimeter Trim

Similar documents
PERIMETER TRIM. Infinity PRODUCT GUIDE. USA and Canada: / fax: Infinity Perimeter Trim 1

AXIOM Indirect Field Light Coves

AXIOM Direct Light Coves Assembly and Installation Instructions

SEISMIC CEILING SUSPENSION

AXIOM Indirect Light Coves

METALWorkS. RH200 Custom Hook-on Panels. General Installation Instructions. Ceiling 1.0 GENERAL Site Conditions Product Description

Manufactured by United States Gypsum Company 550 West Adams Street Chicago, IL 60661

Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

AXIOM Building Perimeter System Assembly and Installation Instructions

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

Easy Elegance Ceiling Panel Installation Instructions

CEILING & WALL SYSTEMS

Axiom Building Perimeter System

Installation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

AXIOM Building Perimeter System

METALWORKS, OPTIMA. and SPECTRA Capz. Installation Instructions /15/08 Patent No For best installation results:

INSTALLATION GUIDE GUIDE TO ASC ISO-WALL CONSTRUCTION SYSTEM APPLICATION ISO-WALL SYSTEM. ASC Iso-Wall System Includes: Materials Required:

Make Waves. Topo 3-Dimensional System

DETAIL INSTRUCTION No. 1

Rockfon Concealed Acoustical Ceiling Systems (CDX and SCD)

Rockfon Concealed Acoustical Ceiling Systems (CDX and SCD)

Suggested Materials and Tools:

SECTION GYPSUM BOARD & SHEATHING SYSTEMS

OPTIMA Concealed. Installation and Maintenance Guide

Suggested Materials and Tools:

METALWORKS Blades Classics

Freedom Barrier Free Shower Pan Installation Instructions

Freedom Barrier Free Shower Pan Installation Instructions

Impression Graphic panels

LIGHTWEIGHT AND ECONOMICAL

SECTION GYPSUM BOARD PART 1 - GENERAL

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

SECTION GYPSUM BOARD

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

SECTION DRYWALL GRID LINEAR LIGHTING INTEGRATION

Install Instruction LOOP RECESSED

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

The GlasRoc Shaftliner Type X advantage...

Freedom One-Piece Barrier Free Showers Installation Instructions

MAKING IT STICK: Nails and screws, adhesives and compounds... today contractors have a wide variety of choices.

OPTIMA Vector Plank Installation Instructions

Optima Vector Plank. Installation Instructions. Ceiling

OmniFlex 300 Plus Installation Instructions

THIS SECTION IS BASED ON ROCKFON S PLANOSTILE SNAP-IN METAL CEILING PANELS.

References in blue are general indicators to the specifier. If not used it can be deleted, but may be needed in the future.

Rockfon Concealed Acoustical Ceiling Systems (CDX) for Seismic Category D, E, F Applications

Pittsburgh Corning ProVantage Glass Block Installation System Assembly Instructions

Cornerview Shower Enclosure & Base

ASC ACOUSTIC. ASC IsoDamp Guide to High Performance Soundproofing. Table of Contents SCIENCES CORPORATION. Introduction Page 2

SECTION ACOUSTICAL PANEL CEILINGS

EDGE D2 CONNECT GRID. Design and technique. Installation manual. Load. Product description. Stability. Plenum height. Weight.

Installation guide. ROCKFON System Z mm. 600 mm

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

SECTION GYPSUM BOARD

a3 CERAMICSTEEL FLOW TECHNICAL GUIDE

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

General applications. Fast. Easy. Customer Focused.

METALWORKS RH215 Faceted Custom Hook-on Panels

SECTION LINEAR METAL CEILINGS

OPTIMA and LYRA Concealed

6x5. Assembly Manual CAUTION. Sharp Edges PATENTS ARE PENDING. Building Dimensions. Approximate Size. Storage Area. Interior Dimensions

Optima Vector Ultima Vector

A. Flat corner wall-to-wall See page 8. C. Outside corner wall-to-wall See page 8. B. Inside corner kit wall-to-wall See page 7

REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER

Product Guide Specifications SECTION ACCESS DOORS/PANELS

Pittsburgh Corning Glass Block Shower System Mortar Installation Standard Fit Shower Instructions

SECTION ACOUSTICAL CEILINGS (CEMENTITIOUS WOOD FIBER CEILINGS)

SECTION GYPSUM BOARD

INSTALLATION INSTRUCTIONS

OPTIMA Vector ULTIMA Vector

technicalnote Seismic Category D, E, F Installation Details Fully Concealed Rockfon CDX FIELD INSTALLATION Grid

Knauf Wall Liner. Head Track. Brackets. Wall Lining Stud. Fixings. Knauf Plasterboard. Floor Track. 98 Wall Liner

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

Weep Valves Stucco Wire Mesh Reinforcement Weather Resistive Barrier Sheathing Insulation Framing

Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips)

METALWORKS Torsion Spring

Installation Guide December 2012

THIS SECTION IS BASED ON ROCKFON S PLANOSTILE D LAY-IN METAL CEILING PANELS.

SECTION GYPSUM BOARD ASSEMBLIES

DLED-9000 LED Miniature Series INSTALLATION INSTRUCTIONS

SECTION NON-STRUCTURAL METAL FRAMING

OPTIMA, ULTIMA, and LYRA Vector

Installation Guide and Safety Manual QuietClip (Resilient Sound Isolation Clips)

Container Installation Guide

OptimA, Ultima, CALLa, and LYRA Vector

Prior to training with this module, it is recommended that the trainee shall have successfully completed Core Curriculum.

SlimLine Single Threshold Base & Q-Wall-5.1 BASE & BACKWALL INSTALLATION INSTRUCTIONS

The Finishing Touch. Compässo. Trim Systems Design Guide

Technical Data Sheet

Integrated LIGHTING. Solutions

where high efficiency is the standard

SECTION GYPSUM BOARD

Virtually Invisible Access Panels

(1) Preparing the Platform for Install

Student Services & Classroom Addition

Prime Shower Enclosure & Base Kit

SECTION GYPSUM BOARD SYSTEM

Prime Shower Enclosure & Base

ALL-ALUMINUM DOOR & WINDOW FRAMING

SAN DIEGO STATE UNIVERSITY PACIFIC CORNERSTONE ARCHITECTS TENOCHCA HALL PROJECT NO FAN COIL UNITS, RESTROOM AND FINISH RENOVATION

Transcription:

INSTALLATION INSTRUCTIONS Infinity Perimeter Trim Infinity Infinity R (Reveal) Infinity Z (Razor Edge) Infinity D (Drywall) Infinity RD (Reveal for Drywall) Infinity ZD (Razor for Drywall) Paired Infinity Bracket Always follow good safety practices. Metal edges are sharp, take appropriate precautions. Prior to beginning the installation ensure that all materials are received and in good condition. Record any shipping damage on the carriers bill of lading and contact CMC immediately to order replacement material. Fax replacement material orders, including a purchase order number to 888.329.2620. 1 Tools Flathead screwdriver Phillips screwdriver Tape measure Leveling device (laser) Marking tool (pencil) Clean gloves Aviation pliers (for hanger wire installation) Tin snips (in case cutting is required) Latex caulk 2 Prep epar aration ation 2.01 Verify weather tightness of the area and begin installation only after wet trades have completed their work and temperature and humidity conditions closely approximate interior conditions which will exist when the area is complete and occupied. 2.02 Locate and review the project installation drawing and details provided. 2.03 Infinity Trim are individually identification marked and their location is shown in the project installation drawing.

3 Hangers 3.01 Install hanger wires at locations shown on the project installation drawing. Note: Hanger wires are typically not included with Infinity Trim and must be ordered separately. Hanger Wire 4 Grid 4.01 Install main and cross tees as shown in project installation drawing. 4.02 Add hanger wires to support any unsupported cantilevered grid. 4.03 Cut grid to form intersections with Infinity Trim using the appropriate cross section(s) shown below. 4.02 7 /16 1 1 /8 5 11 /16 Infinity Infinity R (Reveal) Infinity Z (Razor Edge) 7 /16 7 /16 5 11 /16 Infinity D (Drywall) Infinity RD (Reveal for Drywall) Infinity ZD (Razor for Drywall)

5 Infinit inity y Trim 5.01 Locate and identify Infinity Trim parts relative to the grid layout as indicated on the project installation drawing. 5.01 5.02 Attach Infinity Trim end-to-end using 414 splice plates and secure with screws provided. Do not overtighten. 5.02 414 Splice Plate 5.03 For acoustical panel Infinity applications 5.03 For drywall Infinity applications 430 Splice Plate 5.03 Attach Infinity Trim to grid with 430 Grid Clip. Secure 430 clip to trim within groove. Screw grid to clip using two 404 ( 8 self drilling) screws. 5.04 447 Horizontal Multi-angle Splice Plate 5.04 429 Outside Corner Splice Plate Add bead of caulk to inside joints to minimize light leaks. 5.04 417 Inside Corner Splice Plate 5.05 Brace 5.04 Attach Infinity Trim at corner using inside corner bracket 417, outside corner bracket 429, and multi-angle razor bracket 447. Secure with screws provided. Do not overtighten. 5.05 Add bracing as needed for larger profile Infinity Trim components.

METAL: Infinity / 09 53 13 Installation 6 Panels 6.01 Cut holes for sprinklers, lights, etc., as required prior to installing panels. 6.02 Cut perimeter panels to fit and install. 6.03 When installing CMC Planostile Snap-in panels, use 448 Grid Adapter Clips and 63.26.202 Wall Springs. 6.02 Acoustical panel with Infinity Perimeter Trim 448 Grid Adapter Clip 63.26.202 Wall Spring 6.03 Planostile panel with Infinity Perimeter Trim 6.03 Planostile panel with Infinity R Perimeter Trim 6.03 Planostile panel with Infinity Z Perimeter Trim 7 Pair aired Infinit inity Trim 7.01 Locate and identify trim parts as indicated on project installation drawing. 7.02 Install hanger wires at location shown on project installation drawing (4 increments). Note: Hanger wires are typically not included with Infinity Trim and must be ordered separately. 7.03 Pair Infinity Trim components together using 446.36 ( 3 /4 opening) or 446.46 (1 3 /8 opening) Brackets. Brackets slide within Infinity Trim groove to set position. 7.04 Attach Infinity Trim end to end using 414 Splice Plate. Secure with provided screws (do not overtighten). See 5.02. 7.05 Attach Infinity Trim at corners using 417 Inside Corner Bracket and 429 Outside Corner Bracket. Secure with provided screws (do not overtighten). See 5.04. 446 Brackets B A Panel Spacing 446.36.00 446.46.00 A = 2-1/4 panel to panel face A = 2-7/8 panel to panel face B = 3/4 open between panels B = 1-3/8 open between panels

8 Drywall all (Infinit inity y D/RD /RD/ZD ZD) 8.01 Install drywall grid framing as shown on project installation drawings. 8.02 Cut grid to form intersections with Infinity Trim using appropriate cross section(s) shown below. 8.03 Install Infinity Trim (see Section 5 Infinity Trim for details). 8.04 Install 5 /8 gypsum board as specified in project installation drawing. 8.05 Lay out drywall surface with chalk/pencil lines and cut with router or drywall knife. 8.06 Attach drywall to drywall grid system using selfdrilling or standard bugle head drywall screws. Check for protrusion of screw heads by drawing a finishing knife across the entire surface length. 8.06 Screw 5 /8 drywall to furring grid system 8.07 Tape and mud using industry standard drywall joint procedures. Note: Tape should not overlap the Trim shoulder profile. 8.08 Apply paint according to manufacturer instructions. Trim is treated with a chemical coating for bonding of joint compound and paint. 8.09 Add bracing as needed for larger profile Infinity Trim components. 8.07 Tape and mud 7 /16 7 /16 Brace Infinity D (Drywall) Infinity RD (Reveal for Drywall) 5 11 /16 Infinity ZD (Razor for Drywall) 8.09 Brace

9 Components 10 Cleaning Infinity / Infinity D 12 10 8 6 4 2 Infinity R / RD 6 Infinity Z / ZD 6 6 4 10.01 Select a mild, non-abrasive cleaning agent typically used for cleaning painted or reflective surfaces. Never use abrasive cleaning agents as such treatments may scratch, mar, alter, discolor, and/ or remove the finish. 10.02 Before cleaning the finish, perform a trial test on a section of the finish that will be hidden from view once installed. This will insure that the cleaning agent selected is appropriate and will not damage the finish in question. 10.03 Once an appropriate cleaning solution has been selected, care should be taken to use only that amount which is necessary. Do not soak the ceiling components with the solution. 10.04 Use a clean soft sponge or cloth when applying the cleaning agent in order to insure that the applicator does not contain any abrasive elements that may damage the finish in question. 10.05 Any excess cleaning solution should be removed immediately so that the solution does not dry and possibly leave a residue. In the event that a large area needs to be cleaned, it s advisable to break the area down into smaller, more manageable sections so that adequate time is available to complete each phase of the cleaning cycle. 10.06 After cleaning the soiled or smudged area, wipe the surface with a dry soft cloth to remove any residual cleaning solution and dry the area. Use a clean damp cloth to remove any residue that cannot be removed with the dry cloth. Repeat the drying process. 10.07 After the components are clean, allow a few minutes for air drying before installation. It is important that the clean components are dry because other ceiling material, such as insulation, which may come into contact with the cleaned components, can be susceptible to damage from moisture. Ceiling Systems and Specialty Products - USA and Canada: 800.323.7164 / Fax: 800.222.3744 / chicagometallic.com CHICAGO / BALTIMORE / LOS ANGELES / BELGIUM / DENMARK / UK / GERMANY / FRANCE / HONG KONG / PRC / MALAYSIA / UNITED ARAB EMIRATES / MEXICO Chicago Metallic and its logo are Registered Trademarks of Chicago Metallic Corporation. 2006 Chicago Metallic Corporation All Rights Reserved M-INSTALL-Infinity-0906 Printed in USA