SECTION PLATE CONNECTED WOOD TRUSSES

Similar documents
C. Delegated-Design Submittal: For metal-plate-connected wood trusses indicated to comply with

SECTION METAL PLATE CONNECTED WOOD TRUSSES PART 1 - GENERAL 1.01 RELATED DOCUMENTS

A. Provide all wood trusses as indicated on the drawings or as required to do a complete job.

SECTION SHOP-FABRICATED WOOD TRUSSES

PART 1 GENERAL SHOP FABRICATED WOOD TRUSSES

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SECTION COLD-FORMED METAL TRUSSES

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

A. The work under this section consists of furnishing and installing gauge steel framing and bracing as indicated on the drawings and as specified.

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

Attachment A. USG Minimum Design and Construction Requirements for Wood Framed Structures

STATE UNIVERSITY CONSTRUCTION FUND. UNIVERSITY CON DIRECTIVE 5-1 Issue date: October 2014

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

POST FRAME BUILDING STANDARDS

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

SECTION COLD-FORMED METAL FRAMING

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

FIGURE R502.2 FLOOR CONSTRUCTION

COMMENTARY TO ANSI/TPI/WTCA METAL PLATE CONNECTED WOOD TRUSSES Revised 2002

RESPONSIBILITIES IN THE DESIGN PROCESS INVOLVING METAL PLATE CONNECTED WOOD TRUSSES

SECTION (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES

SECTION COLD-FORMED METAL FRAMING

Specifying Pre-Engineered CFS Floor and Roof Trusses 551f-98

A. Section Metal Decking. (05300 in MF95) B. Section Cold Formed Metal Framing. (05400 in MF95)

SECTION COLD-FORMED METAL FRAMING

Typical Deck Details Based on the 2009 International Residential Code (Designed and Printed August 2010)

SECTION STEEL JOIST FRAMING

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

BEARING METAL STUD FRAMING

LPI 56 Technical Guide

GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION REROOFING ADJUSTABLE FRAMING SYSTEM

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

Long Span Truss Installation

Position Statement on Sealed Truss Placement Diagrams for Projects in the State of California

DECK PERMIT APPLICATION

A. Product Data: For each type of cold-formed steel framing product and accessory.

SECTION METAL STAIRS

CHAPTER 5 FLOORS SECTION R501

STRUCTURAL STEEL FRAMING

Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

Building Division Informational Handout

Union County Vocational - Technical Schools Scotch Plains, New Jersey

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

Insulating Cellular Concrete Steel Joists Painting. A. America Society for Testing and Materials (ASTM):

WOOD I-JOIST AWARENESS GUIDE

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

Interior Hangers. Application

GLOBAL LVL HEADERS, BEAMS AND COLUMNS. 1.9E-2850Fb. 1.9E-2850Fb. User guide User guide. lvlglobal.com

COFS Mission. AISI Standards Hierarchy. North American Standards for Cold-Formed Steel Framing. Member versus System Design. Specification 10/21/2016

STATEMENT OF SPECIAL INSPECTION FORM

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

SECTION METAL STAIRS

SECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SSL-175. Specifications

CHAPTER 5 FLOORS SECTION R501

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

INTRODUCTION. GANG-NAIL Truss System

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

STEEL DECK INSTITUTE Industry Standard Terms & Definitions

Industry Standard Terms & Definitions Of The Steel Deck Institute

******************************************************************************

INSTALLATION. General. Important Note. Design. Transport

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016

1 Exam Prep BCSI Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses Questions and Answers

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Manufactured decking (composite) may be used when approved by the building department

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

Statement of Special Inspections 2013 CBC

DIVISION 5 METALS BUSHEY FEIGHT MORIN ARCHITECTS INC. 473 NORTH POTOMAC STREET HAGERSTOWN, MARYLAND FAX:

Section Downloads. Design Responsibilities Outline. The Need for Standard Design Responsibilities. Non-Conforming Specifications

Architectural Roof and Wall Products Guide Specifications

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

Plan Check No. Checked by: An Appointment Is Required for Verification

SECTION STEEL DECKING

Originally Issued: 03/31/2017 Valid Through: 04/30/2018

SECTION CLIMBING WALLS

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

POST AND FRAME STRUCTURES (Pole Barns)

BROADSPAN. I-Joist Design Brochure. Design properties for I-joist applications in the U.S. for residential floor systems. I-Joist Design Brochure

SECTION STRUCTURAL STEEL

PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA (831) FAX: (831)

Structural Criteria for Residential Rooftop Solar Energy Installations

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

Transcription:

SECTION 06173 PLATE CONNECTED WOOD TRUSSES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Shop fabricated wood trusses for roof and floor framing. 2. Bridging, bracing, and anchorage. B. Related Sections: 1. Section 06100 - Rough Carpentry. 1.02 REFERENCES A. Reference Standards: See Section 01400. Comply with following: 1. TPI 1 - National Design Standard for Metal Plate Connected Wood Truss Construction; Truss Plate Institute. 2. TPI DSB-89 - Recommended Design Specification for Temporary Bracing of Metal Plate Connected Wood Trusses; Truss Plate Institute. 3. TPI HIB-91 - Commentary and Recommendations for Handling, Installing & Bracing Metal Plate Connected Wood Trusses; Truss Plate Institute. 1.03 SYSTEM DESCRIPTION A. Design Floor Load: 1. Top Chord Liveload: 40 PSF. 2. Top Chord Deadload: 20 PSF. 3. Bottom Chord Deadload: 5 PSF. 4. Deflection: Maximum L/480 (Live Load) L/360 (Total Load). B. Design Roof Load: 1. Top Chord Liveload: 21 PSF. 2. Top Chord Deadload: 7 PSF. 3. Bottom Chord Deadload: 10 PSF. 4. Deflection: Maximum L/360 (Live Load), L/240 (Total Load). C. Minimum Truss Depth To Accommodate Mechanical Ducts: Coordinate ductwork passing horizontally through trusses with Mechanical Drawings. 1.04 SUBMITTALS A. See Section 01300 - Administrative Requirements, for submittal procedures. 1. Shop Drawings: Indicate framing plans, sizes, pitch, span, and spacing of trusses, loads and truss cambers, framed openings; sizes and grades of lumber; gauge thickness, nominal sizes and locations of connectors at joints; bearing and anchorage details; permanent bracing and bridging and related items. Submit design calculations and shop drawings signed and sealed by a registered Professional Engineer in the State of Maryland. a. Bearing Points: Size truss members to avoid wood crushing at bearing points based on properties of wall plate material and available wall width indicated on Drawings. 1) Where wood crushing capacity is exceeded, increase number of truss plies or add bearing block(s) in field and attached according to nail or bold schedule indicated on Shop Drawings. 2) Shop Drawings may be rejected which indicate bearing width greater than that indicated on Drawings or which indicate square inches of bearing required without providing instructions on how to accomplish this. PLATE CONNECTED WOOD TRUSSES 06173-1

b. Shop Drawing and calculations : Bear seal of Professional Engineer registered in State of Maryland. c. Truss Layout Drawings: Labeled indicating project name, building number and unit type, and individual truss types corresponding to Shop Drawings. 1) Hangers Attached to or Supporting Trusses: Labeled on Truss Layout Drawings with hanger type and manufacturer indicated. 2) Do not use Framing Drawings (Contract Documents) to quantify exact number of trusses or framing members required. Provide additional trusses as required to properly support all conditions indicated in Contract Documents. 2. Design Calculations: Submit complete calculations with axial forces, moments, external reactions, plate values, design assumptions, and additional information in accordance with TPI. a. Design Calculations: Bear seal of professional engineer registered in State of Maryland. 3. Manufacturer's Instructions: Submit manufacturer's instructions for lateral bracing in accordance with Section 01300. 4. Product Data: Provide truss configurations, bearing and anchor details, bridging and bracing. 1.05 QUALITY ASSURANCE A. Truss Design, Fabrication, and Installation: In accordance with TPI 1, TPI DSB-89, and HIB-91. Truss design shall accommodate point loading of shingle storage along any point on ridge members during construction. B. Manufacturer: Company specializing in manufacturing the products specified in this section with minimum five years of documented experience. C. Design: Under direct supervision of a Professional Structural Engineer experienced in design of this Work and licensed in State of Maryland. 1. Multiple Ply Trusses: Attached together to act as single unit under superimposed load. a. Method of Attachment: Indicated on Shop Drawings including sizes and maximum spacings of fasteners. b. Give special consideration to end and edge distance of fasteners, avoidance of metal truss connector plates, net section of wood at bolt holes, and cross-grain tension in truss members. c. Applied Load from Face Mounted Hangers: Provide hangers with flanges tall enough to allow some nailing above neutral axis of truss chord (Above mid-depth of chord). d. Where bolted connections are required at concentrated loads, fabricate vertical member in truss to receive bolts. e. Where tributary members frame into truss girder at mid-height, provide continuous prefabricated member at that location to receive face nailed hangers. Alternatively, size field applied ledgers to receive hanger nails and specify attachment points and fastener requirements where ledger intersects truss members. 2. Top Chord Bearings: Design in accordance with TPI PCT (including Supplement) with diagonal webs at top. a. Make test data substantiating design procedures available for review when reaction limits of TPI PCT are exceeded. b. Design trusses supported at bottom chord bearing notches or end bearing blocks below chord with due consideration for cross-grain tension and eccentric loads which induce in truss members. c. Maintain truss web size, location, and orientation where detailed in Drawings unless otherwise noted. 3. Permanent Bracing to Reduce Buckling Length of Axially Loaded Compression Members: Clearly identify which truss members require this field installed bracing on Shop Drawings and including maximum allowable spacing of continuous lateral braces (CLB). a. Anchor each CLB in accordance with TPI HIB, Figure 36 specifying bracing member sizes and attachments. b. Where CLB are not practical, such as at isolated non-repetitive trusses, design alternate PLATE CONNECTED WOOD TRUSSES 06173-2

T Brace or L-Brace stiffeners and their attachment. c. Take into account any unsheathed truss compression chords as may occur under piggyback or valley framing. 4. Dimensions: Coordinate with Drawings (Architectural and Structural). D. Roof Truss Design: 1. Lower Roofs and Trusses Adjacent to Parapets: Design for snow drift and slide off in accordance with Applicable Code. Coordinate these areas with Drawings, identify them on Truss Layout Drawings, and design trusses to reflect actual field conditions. 2. Shop Drawings: Indicate special loading conditions and differentiate between snow live load and dead load in calculations. 3. Mechanical Equipment: a. Verify and coordinate mechanical equipment sizes, locations, and weights with Mechanical Drawings and indicate on Truss Layout Drawings. Clearly indicate special reinforcement of truss chords under mechanical units where required, including sizes, grades, and method of attachment. b. Verify and coordinate horizontal and vertical duct opening requirements. 4. Prefabricated Components Subject to Out-Of-Plane Bending (Gable Ends): Design for flexure in weak axis (flat bending). a. Indicate basic wind speed and design pressures on Shop Drawings. b. Clearly indicate stiffener requirements or maximum spacing requirements for continuous lateral braces required to reduce bending length of manufactured component member on Shop Drawings. E. Floor Truss Design: 1. Multiple Supports: Where trusses are designed as continuous over multiple supports, uplift reactions shall not exceed dead weight of wall construction (generally only few hundred pounds or less). Where this condition cannot be met, provide separate simple span trusses. a. Do not use provision to cut top chord after truss erection unless prearranged and approved by Contractor. 2. Post or Wall Loads from Floor or Roof Above (Trusses cross or aligned with bearing walls or special girders): Provide trusses with bearing blocks and bearing points to transfer load continuous to foundation. 1.06 REGULATORY REQUIREMENTS A. Conform to applicable code for loads, seismic zoning, other governing load criteria and fire retardant requirements. 1.07 PRE-INSTALLATION CONFERENCE A. Hold conference with truss fabricator s representative, General Contractor, and truss installer in accordance with Section 01700. Include mechanical equipment installer if appropriate. 1.08 DELIVERY, STORAGE, AND HANDLING A. Handle and erect trusses in accordance with TPI HIB-91. 1. Store trusses off ground and under waterproof cover. 2. Store trusses in vertical position resting on bearing ends. 1.09 FIELD MEASUREMENTS A. Verify that field measurements are as indicated. PART 2 PRODUCTS 2.01 MATERIALS PLATE CONNECTED WOOD TRUSSES 06173-3

A. Lumber Grading Rules: As specified in Section 06100 - Rough Carpentry. B. Wood Members: Single top and bottom chord, Stress Group, species, grade, and moisture content as required by engineer's design. C. Plywood Connectors: Graded by APA; waterproof glue; species and grade as required by engineer's design. D. Truss Hardware: Provide necessary metal plates bolts, nuts, washers, steel plates, nails, etc. necessary for truss fabrication. Use correct material of proper size and strength for purpose intended, Structural Notes on Drawings, and applicable building codes. 1. Metal Plates: TPI QSP, hydraulically pressed 20 gauge toothed steel plates, with ASTM A525 G90 hot-dipped galvanized coating or ASTM A792 AZ50 hot-dipped aluminum-zinc coating. 2. Connections: Size, configuration, and thickness as required to transmit stresses plus eccentricities. E. Truss Bridging: Type, size and spacing recommended by truss manufacturer. 2.02 ACCESSORIES A. Wood Blocking, Plates, Support Members, and Framing for Openings: In accordance with Section 06100 softwood lumber, S/P/F species, construction grade, 19 percent maximum and 7 percent minimum moisture content. B. Fasteners: Electro-galvanized steel, type to suit application. C. Bearing Plates: Electro-galvanized, plain steel. D. Hangers: 1. Strap Hangers: Provide solid blocking to receive face nails through straps or provide backup data for alternate installations. 2. Face Nailed Hangers Without Straps: Provide sufficient depth so that nailing can be provided above neutral axis (above mid-depth) of supporting beam. 2.03 FABRICATION A. Shop fabricate trusses in accordance with recommendations of Truss Plate Institute (TPI) Reference Standards to achieve structural requirements specified. B. Brace wood trusses in accordance with TPI DSB-89 and TPI HIB-91. PART 3 EXECUTIONS 3.01 EXAMINATION A. Verify that supports and openings are installed at proper locations and elevations and ready to receive trusses. Comply with Section 01400. 3.02 PREPARATION A. Coordinate placement of bearing items. B. Coordinate clearances for ductwork, plumbing, and flues with Mechanical Drawings. 3.03 ANCHORS AND SUPPORTS A. General: Provide and install rough hardware and metal fastenings as indicated, specified and required for proper installation of trusses. Provide nails, spikes, screws and bolts and similar items PLATE CONNECTED WOOD TRUSSES 06173-4

of sizes and types to properly secure members in place. 3.04 ERECTION A. Install trusses in accordance with manufacturer's instructions. Hoist trusses into position taking care to prevent damage to truss members or joints by out-of-plane bending. 1. Handling and Erection: Comply with TPI HIB. 2. Set members level and plumb, in correct position. 3. Plane of Truss Webs: Vertical, plumb, parallel to each other, and located accurately. B. Make provisions for erection loads, and for sufficient temporary bracing in accordance with TPI HIB and DSB, to maintain structure plumb, and in true alignment until completion of erection and installation of permanent bracing. 1. When required by Building Inspector or Truss Fabricator, or elected by erector, to engage professional engineer or architect to supervise truss erection; provide design and certification of temporary and erection bracing system by structural engineer in accordance with TPI DSB. C. Bearing and Anchorage: Ensure truss ends have sufficient bearing area, and anchor trusses securely at bearing points. D. Do not field cut or alter structural members without approval of Architect, Engineer and truss manufacturer. E. Permanent Bracing for Overall Stability of Structure: Install permanent bracing and bridging prior to application of loads in accordance with Drawings (including details, sections, and notes). 1. Bracing: Intended to provide lateral stability and transfer wind shear to shear walls and floor and roof diaphragms. F. Place headers and supports to frame openings required. G. Frame openings between trusses with lumber in accordance with Section 06100. H. Coordinate placement of decking with work of this section. I. After erection, touch-up primed surfaces with primer consistent with shop coat. J. Floor Trusses: 1. Strongbacks: Install at 10 feet (3 m) OC maximum spacing (Two lines of strongbacks at spans over 20 feet (6 m). Anchor each line of strongbacks at both ends as required by TPI PCT. Accomplish by either nailing to rigid wall or with cross bracing. 2. Ladder Trusses (Typical wherever adjacent trusses run parallel to walls): Provide with vertical members of size and spacing as indicated on Drawings. a. Prefabricate or field install wood blocking for transfer of post loads. b. Where ladder trusses are located within designated shear walls, provide bracing per structural drawings. 3.05 TOLERANCES A. See Section 01400. Comply with following tolerances: 1. Framing Members: 1/2 inch (12 mm) maximum, from true position. END OF SECTION PLATE CONNECTED WOOD TRUSSES 06173-5