ASEPTIC BIOPHARMACEUTICAL MANUFACTURING: FAQs

Similar documents
NHS QA Symposium, September 2013

BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER ROOT CAUSE INVESTIGATION GUIDANCE

BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER SAMPLE AND COLLECTION EFFICIENCY

Environmental Monitoring of Aseptic Processing Areas - 2

Microbial Detection. Continuous At-Line Microbial Monitoring For Pharmaceutical Waters

How to Handle Excursions in Environmental Monitoring (EM) and Personnel Monitoring (PM) in an Aseptic Processing Plant

Environmental Monitoring of Aseptic Processing Areas - 1

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Indoor Air Quality Tools

BREATHE A LITTLE EASIER WITH TSI

LABORATORY CONTROL SOLUTIONS FROM TSI

THE LEADER IN PERFORMANCE VENTILATION MEASUREMENTS

Cleaning Validation PRODUCT OVERVIEW

Sievers 500 RL On-Line TOC Analyzer

Overview of a sterility assurance program for PET drugs

Instantaneous Microbial Detection for Pharmaceutical Waters. IMD-W Instantaneous Microbial Detection System

Supplementary Training Modules on Good Manufacturing Practice. Validation. WHO Technical Report Series, No. 937, Annex 4.

FZ LABORATORY SERVICES

Advances in Sterility Assurance: Single Use Devices and Rapid Microbiological Tests

Biocontamination control in pharmaceutical production

PERFORMANCE QUALIFICATION PROTOCOL HVAC SYSTEM

STANDARDS FOR COMPOUNDING PHARMACIES

Airborne Particle Detection

UNDER SECRETARY FOR HEALTH S INFORMATION LETTER MICROBIOLOGICAL ASSESSMENT OF PHARMACEUTICAL CLEANROOMS

On behalf of the PHSS Pharmaceutical and Healthcare Sciences Society (UK).

Implementation of Enhanced Active Air Particle Counting. Jeffrey W. Weber Kalamazoo, MI May 5, 2015 PDA Midwest

Contents. Contents (13) 1 Production (23)

Particle Sample Tube Lengths for Pharmaceutical Monitoring. Version 01. Rev 01.

Rapid Microbiological. PDA: A Global. Methods. Association. Gilberto Dalmaso Aseptic Processes Development Manager

MODEL 3340 LASER AEROSOL SPECTROMETER

Environmental Control Requirements. Gordon Farquharson July 2017

Streamline your microbial detection workflow with the Milliflex platform.

Indoor Air Quality Solutions

Fluorescent Sensor Detects Microbes in Real Time

Spectroscopy Solutions for Pharmaceuticals:

VHP M100 Biodecontamination Systems: Open Loop

At Your ServIce. Microbiology Services. The life science business of Merck operates as MilliporeSigma in the U.S. and Canada.

Automated compounding for intravenous chemotherapy

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

Streamline your microbial detection workflow with the Milliflex platform.

Why Do I Test, What Do I Test & When Do I Test It? Ross Caputo, PhD Chief Technical Officer Eagle Analytical Services

Overview and Introduction Annex 1 Revision

BFS IOA BFS Training 2018 Kunming Qualification and Validation of a BFS-Installation including CIP/SIP

ProCellics. In-Line & Real-Time Bioprocess Raman Analyzer

When Quality Matters. Microbial Air Samplers: Selection Criteria in Biopharma Manufacturing. Celebrating Over 50 Years In Business!

Standard Monitoring System

Sievers M9 TOC Analyzers

HVAC and Risk Management RACI Meeting 7 th December Agenda. Design. Project Management. Context. Qualification. Construction

AMI INTEGRITY TEST SYSTEM. Innovative solutions for the pharmaceutical industry

TurboMatrix Headspace and Headspace Trap Samplers

ProODO Optical Dissolved Oxygen Meter for the Lab or Field SPECIFICATIONS

Your Goal is Zero Positives. So is Ours.

Melting Point M-565 Technical data sheet

PhEn-602 Notes # 4 J. Manfredi

Recent USP Updates May, 2013

USP <1116> and Contamination

Automatic hardness testing devices

UV300 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

PDA: A Global. Association. Contamination Control: Particles, Bio-contamination, Aseptic manufacturing. PDA Parenteral 2014 Munich Conference

Microbiological Consideration for Non-Sterile Pharmaceutical

Measurement & Analytics Measurement made easy. TALYS ASP310 An affordable high precision wet bath monitoring analyzer

Erin Patton, MS Senior Product Specialist Charles River Labs, Microbial Solutions

5000TOCi with ISM. Fast, Continuous and Reliable Total Organic Carbon Measurement

The Benefits of Integrating Metal Detection into Your Product Inspection Program for Consumer Safety. Antoine Dodier & Hitesh Hirani

Thermo Scientific Insight 2 Software for Evolution 200 Series UV-Vis Spectrophotometers. Comprehensive solutions Simplified workflows

CHRONICAL CLIMET. April 2016 Newsletter. Celebrating Over 50 Years In Business! Tel. +1 (909) 793.

Validation Guide USTR 2114 (2) Validation Guide for Pall Emflon PFR Filter Cartridges

Liquid Metal Cleanliness Analyzer for Continuous Monitoring

Cyto-Mine. The Single Cell Analysis and Monoclonality Assurance System

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

The Leader in Performance Indoor Air Quality Measurements

The Leader in Performance Indoor Air Quality Measurements

YSI Biochemistry Analyzer. Speed and Accuracy Made Simple

SPOT HIGH PRECISION PYROMETERS A PRODUCT OF THE SYSTEM 5 FAMILY. 50 to 1800 C / 122 to 3272 F QUALITY CUSTOMER SOLUTIONS

Compounding Aseptic Isolators (CAI) James T Wagner

QbD1200 TOTAL ORGANIC CARBON ANALYZER RELIABLE MEASUREMENT MADE SIMPLE.

Thermoforming packaging machine R 145 with MULTIVAC Clean Design. Maximum process reliability and cleanroom suitability

The reliable platform for your automated microelisa testing

LiMCA CM. Liquid Metal Cleanliness Analyzer for Continuous Monitoring

3M Purification Inc. Technical and Scientific Services Global Support for the Life Science Industry. Global Expertise delivered locally

Rapid Microbiological Methods Understanding the Technologies and Regulatory Expectations for Validation and Implementation

Whitley Automated Spiral Platers

Milliflex Rapid Microbiology Detection System

Compact Weighing Systems

USP Chapter 823 USP 32 (old) vs. USP 35 (new)

INSPECTOR S OBSERVATIONS AND WARNING LETTER

Whitley Automated Spiral Platers

MICROBIO BIOAEROSOL SAMPLING

IN SITU STERILIZABLE BIOREACTORS

Packaging Operations Technical Subcommittee

Highly Accurate, Reliable and Real-time Enumeration of Individual Bacteria for the Determination of Raw milk Hygienic Quality

Best Practice in Environmental Monitoring

Automatic Isokinetic Sampler ST5

ISPE Nordic, Denmark Yves Scholler SKAN AG

single-use fermentors

BIO & PHARMA ANALYTICAL TECHNIQUES

Validation Strategies for Equipment from Multiple Vendors

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter

EPA Compliant Turbidity & Chlorine Meter

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Transcription:

ASEPTIC BIOPHARMACEUTICAL MANUFACTURING: FAQs THE BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER UNDERSTANDING, ACCELERATED

REDUCE RISK INCREASE EFFICIENCY IMPROVE PROCESS UNDERSTANDING The BioTrak Real-Time Viable Particle Counter enables aseptic biopharmaceutical manufacturing facilities to reduce risk, increase efficiency and improve process understanding. The BioTrak Particle Counter is three instruments in one; offering continuous ISO-compliant optical particle counting, real-time viable particle counting, and microbial sample collection for identification. For aseptic manufacturing, the BioTrak Particle Counter is best suited for: + + Fixed-position, automated and continuous monitoring of the aseptic core + + Routine certification and episodic monitoring of cleanrooms throughout a facility In either application, the BioTrak Particle Counter offers enormous cost savings over traditional growth-based methods. By eliminating the need for manual agar plate changes in the aseptic core, manufacturers are able to reduce process interventions and line stoppages, cut production downtime, and avoid wasted product, sub-lotting or extra sterility testing. The BioTrak Particle Counter can demonstrate environmental control in real-time to increase readiness, avoid excessive sterilization cycles and minimize air exchange rates. Furthermore, because the instrument provides both total and viable particle counts, as well as sample collection capability, it is the ideal all-in-one solution for simple, cost-effective environmental monitoring throughout a facility. 1 The BioTrak Particle Counter is three instruments in one 2 1. ISO-compliant non-viable particle counter 2. Dual-channel LIF viable particle counter 3. 9-hour microbial collection filter 3 1

THE BASICS Q1. How does the BioTrak Particle Counter discriminate microorganisms from non-viable particles? A: The optical properties of microorganisms are substantially different from non-viable particles. Non-viable particles simply scatter light. Microorganisms (bacteria, mold, yeast) contain fluorescent molecules which absorb and re-emit light in unique ways. The BioTrak Particle Counter exposes incoming particles to laser light at 405 nm. Particles containing fluorescent components (i.e. microorganisms) re-emit light at higher wavelengths; a process called Laser Induced Fluorescence (LIF). A particle s viable or non-viable status is determined by its fluorescent properties and its size (measured simultaneously by light scattering). Q2. How does the BioTrak Particle Counter achieve superior viable discrimination? A: It records more information from each airborne particle. Laser Induced Fluorescence (LIF) (see question 1) produces a continuum of emitted wavelengths (the emission spectrum). Other LIF-based instruments detect these emissions in a single wavelength region; the BioTrak Particle Counter detects emissions in two distinct wavelength regions (dual-channel LIF). Two fluorescence parameters, combined with particle size, provide more data for superior discrimination. Q3. Does the BioTrak Particle Counter count non-viable particles as well? A: Yes, it provides ISO-compliant total particle data. Before particles enter the viability detector they are first sized and enumerated by a dedicated, 650-nm optical particle counter (OPC). ISO 21501-4 compliant, the BioTrak Particle Counter reports total particle concentrations in 6 size channels according to ISO 14664-1. Combining total particle data with viable counts and identification via the gelatin filter, the BioTrak Particle Counter is the ultimate integrated tool for certifying and monitoring clean rooms. Q4. Does the BioTrak Particle Counter integrate with environmental monitoring systems? A: Yes, allowing automated operation and data collection. The BioTrak Particle Counter seamlessly integrates with TSI s robust and flexible Facility Monitoring System (FMS) software. FMS is compatible with a large variety of monitoring instruments for reliable operation and data management. Data integrity is critical; integrated environmental monitoring systems are a key component of meeting regulatory expectations. 2

BIOTRAK PARTICLE COUNTER V Q5. How do BioTrak Particle Counter viable counts (vcnt) compare to traditional colony forming units (cfu)? A: The two metrics are proportional, but not always equal. Growth-based methods and the BioTrak Particle Counter employ fundamentally different approaches to microbial quantitation and therefore report results in different units; cfu and vcnt respectfully. In validation studies, the BioTrak Particle Counter (vcnt/m 3 ) and slit-to-agar (cfu/m 3 ) results where highly correlated (r 2 >0.95) over 3-orders of magnitude. When sampling virtually aseptic environments, both methods reported zero (see Q 7 ). In real-world, Grade C/D ISO 8 cleanroom environments, the BioTrak Particle Counter is typically more sensitive than growth-based methods due to detection of VBNCs (see Q8). Q6. How does the BioTrak Particle Counter respond in Grade A/ISO 5 environments? A: In rigorously aseptic environments, essentially zero viable particles are detected. The BioTrak Viable Particle Counter has an ultra-low false-count rate. When it samples HEPA-filtered air, viable counts are essentially zero. In fact, this zero-test is part of the operational qualification (OQ). The BioTrak Particle Counter also reports essentially zero viable counts Q7. In the aseptic core, how does the BioTrak Particle Counter improve quality and efficiency compared to traditional methods? A: The BioTrak Particle Counter eliminates interventions for changing agar plates. Traditional microbial monitoring inside the aseptic core requires human interventions for agar plate changes. This activity compromises the integrity of the aseptic environment and defeats the primary purpose of isolators; to exclude human operators. The BioTrak Particle Counter samples air from within the aseptic core but is physically located outside that space, providing continuous real-time microbial data without operator intervention. Q8. Can the BioTrak Particle Counter detect Viable But NonCultureables (VBNCs) as viable particles? A: Yes. TSI s validation studies indicate that the BioTrak Particle Counter detects a substantial proportion (>25%) of certain stressed microbes (a type of VBNC) as viable particles. These stressed organisms were detected at low levels, or not at all, by slit-to-agar instruments. The BioTrak Particle Counter detects VBNCs more sensitively than growthbased methods because detection is not dependent on metabolic status. in actual aseptic manufacturing spaces (e.g. isolators, RABS) where traditional methods yield zero cfu. VIABLE COUNTS IN GRADE A & GRADE C (28.3 L/MIN; 1 SAMPLE/MIN; 35MIN) [Microbiological] Sampling methods used in operation should not interfere with zone protection European Commission GMP Annex 1, page 5 Viable Counts (cumulative) 140 120 100 80 60 40 20 Grade C Grade A 0 0.0 0.2 0.4 0.6 0.8 1.0 Volume Sampled (m 3 ) 3

S. GROWTH-BASED METHODS: Q9. How does the BioTrak Particle Counter respond to common interferents? A: Most materials do not produce viable counts, but site-specific studies are encouraged. In validation studies, airborne particles from tryptic soy broth (TSB), ethanol, isopropanol, clean room paper or glove-box sleeves were generally not classified as viable (typically 0-0.5% of total particles). Certain gowning materials produced higher viable counts likely due to shedding of VBNCs (see Q7). Application-specific testing should be performed during the BioTrak Viable Particle Counter validation to evaluate interferents specific to your facility and manufacturing process. Q10. How do users determine alert and action levels for the BioTrak Particle Counter? A: USP <1116> provides relevant guidance. Location-specific baseline data is recommended. The BioTrak Viable Particle Counter is a fundamentally different technique from growth-based methods, and does not quantitate microbes in cfu. Therefore, specific alert/action limits in cfu are not useful. USP <1116> suggests initial alert/action levels in Contamination Recovery Rates (CRR), which are readily applicable to BioTrak Particle Counter data. The guidance encourages users to determine locationspecific CRR baselines and determine alert/action levels accordingly. Q11. Can the BioTrak Particle Counter identify microbes? A: BioTrak Particle Counter supports identification, but not in real-time. The BioTrak Particle Counter discriminates microbes from non-viables in real-time based on size and fluorescent characteristics (see Q1 & Q2). The subtle differences between species are insufficient for unambiguous identification in real-time. Therefore, the BioTrak Particle Counter supports identification by collection and growth via the integrated gelatin filter, validated for 9 hours of continuous collection. Viable and non-viable particle counting operates with or without the gelatin filter. Q12. Does the BioTrak Particle Counter s gelatin filter quantify microbes? A: Microbial quantitation is determined in real-time by LIF, not the gelatin filter. The gelatin filter sample collection device is intended for identification purposes only. It is designed as a qualitative tool to maintain viability of collected organisms for the maximum duration. The gelatin filter collection system is validated for 9 hours of continuous sample collection and does not require intervention into isolators or RABS for access. 4

REGULATORY COMPLIANCE & VALIDATION Q13. Do regulatory agencies embrace Alternative or Rapid Microbial Methods (RMMs)? A: Yes, improving quality through new technology is a priority. Implementing new techniques to improve quality is welcomed and expected. Many practical guidances and regulations are published to aid and encourage use of RMMs including: USP <1223>, USP <1116>, Ph. Eur. Chapter 5.1.6, and PDA Technical Report 33. Many agencies actively encourage improved quality through new technology with Process Analytical Technologies (PAT) and Quality by Design (QbD) initiatives. Q14. What are the options for regulatory approval? A: There are several options for obtaining regulatory approval. PDA Technical Report 33 contains a succinct and practical guide to approval options and is recommended reading for users considering the BioTrak Real-Time Viable Particle Counter for in-process applications. Options include NDA/ANDA submissions, FDA s Comparability Protocol, EC s post-approval change management protocol, and internal change control programs where appropriate. Communication with regulatory agencies early in the development of the validation plan is encouraged. Alternative and Rapid Microbiological Methods have been understood, accepted and encouraged by regulatory authorities PDA Technical Report No. 33 (Revised 2013), page 6 5

Drug Master File: + Physical Efficiency + Accuracy + Precision + Specificity + LOD/LOQ/Range + Linearity + Ruggedness + Robustness Q15. What validation work has already been done to ensure BioTrak Particle Counter compliance? A: TSI has a Type V Drug Master File submitted with the FDA. Inquire with your local TSI partner, or through our website, to review a summary of the validation studies included in the DMF. To directly support users regulatory submissions, or internal change control documentation, TSI has performed rigorous validation work included in a Drug Master File at FDA. TSI has worked with experts, including former regulators, to ensure the BioTrak Particle Counter is properly qualified to support aseptic pharmaceutical manufacturing. Q16. How does TSI support customers during BioTrak Particle Counter validation? A: With dedicated experts and resources, both on-site and off. TSI has a committed team of professionals ready to assist customers during evaluation and validation. In addition to the qualification studies included in the Drug Master File, TSI offers formal documentation, on-site services and expert consultation from IQ/OQ through PQ. Work with your TSI partner to coordinate validation plans and experiments. Leverage TSI s expert knowledge, and benefit from our experience. 6

SPECIFICATIONS BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER MODEL 9510-BD Particle Counting Size Range Particle Channel Sizes 0.5 to 25 μm 0.5, 0.7, 1.0, 3.0, 5.0, 10 μm Size Resolution <15% @ 0.5 μm (per ISO 21501-4) Total Particulate Counting Efficiency Viable Detection Sample Collection Concentration Limit Zero Count Flow Rate Calibration Calibration Frequency Standards Hardware Total Particulate Light Source Viable Particulate Light Source Flow Rate Control Sample Tube Extension Audible Alarm External Alarm Relay Exhaust Vacuum Source Alarm Output Display Printer Dimension (H x W x D) Weight 50% at 0.5 μm; 100% for particles >0.75 μm, (per ISO 21501-4 and JIS) 2 fluorescent channels and 1 sizing channel for discrimination Integrated filter holder for 37-mm diameter filters 820,000 particles/ft 3 (29,000,000/m 3 ) @ 10% coincidence loss <1 count per 5 minutes (per ISO 21501-4 and JIS B9921) 1.0 CFM (28.3 L/min) ±5% accuracy (meets ISO 21501-4 and JIS B9921) NIST traceable using TSI calibration system Recommended minimum of once per year ISO 21501-4, CE, JIS B9921 660 nm laser diode for MIE particle sizing 405 nm laser diode for Laser Induced Fluorescence viability detection Electronic, automatic closed loop (patented* flow control technology) Up to 10 ft (3 m) Built-in; >85 db at 1 meter (adjustable) Normally open contact closure rated for 0 to 60 V AC/DC at 1.5A peak, 0.5A continouos. Alarm output rated for 60 V insulation. Relay contact closes under user configurable alarm conditions. Internal HEPA filter Internal pump Dry contacts, closed when alarm is engaged VGA 5.7-in. (14.5-cm) touch screen display Optional built-in thermal printer 19 in. x 10.5 in. x 11.7 in. (48.3 cm x 26.7 cm x 29.7 cm) 37 lbs (16.8 kg) Power 110 to 240 VAC universal power supply Operating Range 41 to 86 F (5 to 30 C),** 20% to 85% RH noncondensing*** Operating Elevation 0 to 10,000 ft (0 to 3,000 m) Storage Range 32 to 122 F (0 to 50 C), up to 98% RH noncondensing Housing Stainless Steel External Chemical Resistance Isopropyl alcohol, chlorinated solution, hydrogen peroxide Environmental Sensor Interface Supports TSI air velocity, temperature and relative humidity probes User Interface and Communication Sampling Modes Manual, automatic, beep; cumulative/differential; count or concentration Sampling Time 1 second to 99 hours Sampling Frequency Data Storage Status Indicators Alarm Limits Languages Software Printer Output Unit ID Security Reports Communication Mode Accessories Included Accessories Optional Accessories 1 to 9,999 cycles or continuous 250 Zones 999 Locations 10,000 sample records including: Date, time, six total viable particulate size channels, flow status, instrument status; transferable via USB storage device, TrakPro Lite Secure software, Modbus TCP over Ethernet or USB, and optional TSI FMS software. Flow, Instrument Programmable for all particle channels (both total and viable) English, German, French, Spanish, Japanese, Chinese (simplified), Italian TrakPro Lite Secure, optional FMS software Prints in all available languages with optional integrated printer Configurable IP address 2-level password protection to lock out usage and configuration Provides Pass/Fail on ISO 14644-1, EU GMP, and FS209E reports Modbus TCP over Ethernet or USB Printed QuickStart guide, operating manual on CD, power supply, isokinetic probe, tubing, zero count filter, USB cable, TrakPro Lite Secure software, viable filter holder, viable collection filters, cleaning swabs, and calibration certificate Electronic filter scanning probe, basic filter scanning probe, TSI velocity probes, Temp/RH probe, isokinetic probes, sample tubing, hard-sided carrying case, printer paper, and FMS Software * The BioTrak 9510-BD incorporates the following patented technologies: Patent Numbers 6,167,107; 5,701,012; 5,895,922; 6,831,279; 7,261,007. **Maximum temperature limited by gel collection filter. ***See TSI Application Note CC-104 for operation above 50% RH. Specifications are subject to change without notice. BioTrak, TSI and the TSI logo are registered trademarks, and TrakPro is a trademark of TSI Incorporated. Modbus is a registered trademark of Modicon, Inc. UNDERSTANDING, ACCELERATED TSI Incorporated - Visit our website www.tsi.com for more information. USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200 France Tel: +33 1 41 19 21 99 Germany Tel: +49 241 523030 India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388 P/N 5001727 Rev B 2016 TSI Incorporated Printed in U.S.A.