DESIGN OF INFILTRATING BASIN

Similar documents
INFILTRATION BASIN DESIGN AND OVERFLOW RISK

Stormwater Retention Pond Recovery Analysis

INFILTRATION TRENCH DESIGN FOR STORM WATER BMP

Guo, James C.Y. (2002). Overflow Risk of Storm Water BMP Basin Design, ASCE J. of Hydrologic Engineering, Vol 7, No. 6, Nov.

Effect of the Underlying Groundwater System on the Rate of Infiltration of Stormwater Infiltration Structures.

RETENTION BASIN EXAMPLE

Novel Modeling Approach to Understand the Fate of Infiltrated Water at Green Stormwater Infrastructure in Philadelphia, PA

Key Words: Stormwater, Retention, Detention, Water Quality, Urban, Hydrology.

AN APPROACH FOR ESTIMATING INFILTRATION RATES FOR STORMWATER INFILTRATION DRY WELLS

LID PLANTER BOX MODELING

Comparing Treatment and Siting Criteria for Stormwater BMPs near Drinking Water Supply Areas

ENGINEERING HYDROLOGY

WHAT IS SOIL? soil is a complex system of organic and inorganic (mineral) compounds Soil properties depend on formation process particle size climate

Modeling Percolation from Multiple Ponds in Close Proximity Using ICPR. The ASCE Suncoast Branch Water Resources Luncheon Sarasota, Florida

An Introduction into Applied Soil Hydrology

4.4 MODEL CODE DESCRIPTION 4.5 WATER SOURCES AND SINKS 4.6 MODEL DOMAIN AND BOUNDARIES. SLR South Africa

Water Resources Management Plan

EART 204. Water. Dr. Slawek Tulaczyk. Earth Sciences, UCSC

Developing an Effective Infiltration Design for Clay Soils

GROUNDWATER TABLE HYDRAULIC IMPACT ASSESSMENT GUIDE FOR INFILTRATION BMPS

Is it time for us to go to fully integrated models for stream-aquifer management?

Rainwater Harvesting for Enhanced Groundwater Recharge Through Capture of Increased Runoff from Site Development

OPTIMAL DESIGN FOR POROUS LANDSCAPING DETENTION BASIN

EXPLICIT FUNCTIONS FOR IMPLICIT RESERVOIR ROUTING

PONDS 3.2 TECHNICAL MEMO

Effluent Conveyance. Paul Trotta, P.E., Ph.D. Justin Ramsey, P.E. Chad Cooper

Infiltration. ro ock and soil. Soil. Unsa aturated Zone. Hydraulic properties? Rock. soil. pores filled with air and water

Drop Height For Channel Erosion Control

Executive Summary. Colorado School of Mines Golden, Colorado

General Groundwater Concepts

ANALYTICAL MODEL FOR SATURATEDlUNSATURATED HYPORHEIC ZONE FLOW DUE TO ALLUVIAL WELL DEPLETIONS. Garey Fox and Deanna Durnford

4.8. Subsurface Infiltration

DRAINAGE & DESIGN OF DRAINAGE SYSTEM

Introduction to Land Surface Modeling Hydrology. Mark Decker

Caesium-137 Transport in an Unconfined Aquifer

Issue paper: Aquifer Water Balance

GROUNDWATER RECHARGE. Clear Creek Solutions, Inc., 2010

Lecture 11: Water Flow; Soils and the Hydrologic Cycle

WATER MASS BALANCE IN THE CASE OF VERTICAL INFILTRATION

Cold Desert Evapotranspiration Cover System Design Evaluation

D.G.S.W. Pitakumbura Manager (Groundwater Studies) Groundwater Section NWS&DB. Groundwater recharge or deep drainage or

Chapter 3 Dispersion BMPs

Suggested Stormwater Management Practices For Individual House Lots

16.0 Water Quality Management Criteria for Developed Land

Water Losses Calculation Model of Irrigation Channel

Surface Water and Non-Wetland Surface Waters Delineation and Classification pursuant Chapter F.A.C.

LINED WATERWAY OR OUTLET (Feet) Code 468

ARTIFICIAL RECHARGE OF CONFINED AND UNCONFINED AQUIFER UTILIZING MULTIPLE WELLS SYSTEM IN ARID AREAS

4.8. Subsurface Infiltration

POROSITY, SPECIFIC YIELD & SPECIFIC RETENTION. Physical properties of

Ground Water Issues of the South Platte River Basin. Presented by: James L. Jehn, C.P.G. Jehn Water Consultants, Inc.

Permeable Pavement Hydrologic Modeling

Permeable Pavement: A New Chapter

An Overview of JULES. Christina Bakopoulou

VOLUME CONTROL using Inter-Event Dry Periods. Stormwater Management Academy UNIVERSITY OF CENTRAL FLORIDA

ABSTRACT & POWERPOINT PRESENTATION

BMP 6.4.4: Infiltration Trench

Standards for Soil Erosion and Sediment Control in New Jersey May 2012 STANDARD FOR GRASSED WATERWAYS. Definition. Purpose

Understanding Hydrologic Process for Better Stormwater Management

Infiltration Trench. Image: Cahill Associates, Inc.

Documentation of Groundwater Agent-based Model

OVERFLOW RISK ANALYSIS FOR STORM WATER QUALITY CONTROL BASINS

FACT FLASH. 5: Groundwater. What is groundwater? How does the ground store water? Fact Flash 5: Groundwater

Infiltration Stormwater Control Measures. Andrew R. Anderson, M.S., E.I.T. Extension Associate Engineer

Hydrology for Drainage Design. Design Considerations Use appropriate design tools for the job at hand:

BMP Crediting Review. MIDS Work Group November 16, resourceful. naturally.

SEES 503 SUSTAINABLE WATER RESOURCES GROUNDWATER. Instructor. Assist. Prof. Dr. Bertuğ Akıntuğ

Municipal Stormwater Ordinances Summary Table

STREET STORM WATER CONVEYANCE CAPACITY

Computation of excess stormflow at the basin scale. Prof. Pierluigi Claps. Dept. DIATI, Politecnico di Torino

3.2 INFILTRATION TRENCH

Stormwater Treatment Measure Sizing and Design Considerations SMCWPPP C.3 Workshop June 21, 2017

Predicting seasonal variation and mounding of groundwater in shallow groundwater systems

Impact of Compaction State and Initial Moisture on Infiltration Characteristic of Soil

For Simulation of Hydrologic and Water Quality Processes in Irrigated Agricultural Watersheds

Water Resources Management Plan Appendix B

1. Apply knowledge of the controlling variables for groundwater flow. 2. Demonstrate groundwater flow direction based on hydraulic head observations.

A HYDROLOGY MODEL FOR MIMICKING PRE AND POST DEVELOPMENT RUNOFF VOLUMES

The Borehole Permeameter Approach for Stormwater Infiltration Testing

StormCon August 2017

CONSISTENCY BETWEEN CUHP AND RATIONAL METHODS James C.Y. Guo, PhD, P.E., and Ben Urbonas, P.E., D.WRD 08/04/2008

Site Design Measures A-3

Infiltration Trench Factsheet

STORM DRAINS AND IRRIGATION

Water balance at the field and watershed scale.

EAGLE DRAINAGE DESIGN STANDARDS

Geotextile Sand Filter

DIFFERENTIATION OF WATER SOURCES USING ANALYTICAL WATER CHEMISTRY DATA

Water Budget IV: Soil Water Processes P = Q + ET + G + ΔS

Groundwater Recharge from Agricultural Areas in the Flatwoods Region of South Florida 1

Modelling LIDs using PCSWMM and EPA SWMM5. March 28, 2012 Presented by: Rob James (CHI) Credit to: Lewis Rossman (US EPA)

CITY OF MONTCLAIR Montclair Civic Center 5111 Benito Street Montclair, CA 91763

University of Arizona Department of Hydrology and Water Resources Dr. Marek Zreda

Groundwater Level and Movement

FLOW AND DISTRIBUTION OF WATER IN UNSATURATED, FRACTIONALLY-WET POROUS MEDIA SYSTEMS

Module 10b: Gutter and Inlet Designs and Multiple Design Objectives

AESI AESI 6/17/2015 HOW AND WHERE DOES INFILTRATION WORK? o Context: Summary of Geologic History. o Constraints/benefits for different geologic units

Stormwater Non-potable Beneficial Uses: Modeling Groundwater Recharge at a Stormwater Drywell Installation. Leila Talebi 1 and Robert Pitt 2

Shaking water out of soils SUPPLEMENTARY INFORMATION

Quantifying Return Flow to Groundwater: What's in the Tool Box?

Transcription:

Guo, James C.Y. (003). esign of Infiltrating Basin b Soil Storage and Conveance Capacities, IWRA International J. of Water, Vol 8, No. 4, ecember. Guo, James C.Y. and Hughes, William. (001). Runoff Storage Volume for Infiltration Basin, ASCE J. of Irrigation and rainage Engineering, Vol 17, No. 3, Ma/June. Guo, James C.Y. (001). esign of Circular Infiltration Basin Under Water Mounding Effects, ASCE J. of Water Resources Planning and Management, Vol 17, No.1, Jan/Feb. ESIGN OF INFILTRATING BASIN James C.Y. Guo, Ph., P.E., epartment of Civil Engineering, Universit of Colorado at enver, enver, CO 8017-3364. E-mail: James.Guo@cudenver.edu Abstract: esign of storm water storage basin must take both surface infiltrating flow and subsurface seepage flow into consideration. This paper suggests that for an on-site storm water disposal facilit, the basin storage volume shall not exceed the soil pore storage capacit. On the other hand, for a long-term groundwater recharging basin, the subsurface geometr at the basin site must be able to sustain the surface infiltrating water. To avoid a prolonged draining operation, an infiltrating basin must be designed with consideration of the soil pore storage capacit before the soil medium is saturated and the soil conveance capacit after saturation. In this stud, the potential flow model is applied to estimate the soil pore storage volume underneath the basin and to predict the conveance capacit through the saturated soil medium between the basin and the local groundwater table. The potential flow model for infiltrating water flow provides a quantifiable basis to define the soil constraints and to compare various alternatives at the basin site. Ke Words: storm water, basin, BMP s, infiltration, seepage, groundwater INTROUCTION Under the Federal Clean Water Act, man best management practices have been developed for on-site disposal of storm water. As a storm water qualit control facilit, an infiltration basin is often designed for micro events at the level of dail runoff, but not for the minor (5-ear) or major (100-ear) events (Guo and Urbonas in 00, Guo 00). When the basin is loaded with storm water, the soil medium between the basin and the groundwater table will first undergo a storage process in which the soil water moisture varies from an unsaturated to a saturated condition. As soon as the infiltrating water reaches the groundwater table, the saturated soil medium will act as a conduit to pass the water flow. The conveance capacit in a saturated soil medium depends on the hdraulic gradient and the soil conductivit. If the underground seepage flow through the soils cannot sustain the surface infiltrating water, the soil-water sstem will be backed up and a water mound will begin to build up. The shape and growth of water mound depend on the rate of infiltrating flow, size of the basin, and hdraulic properties of the soil mediums (Ferguson 1990, Guo 001). The soil hdraulic conductivit varies with respect to the water content in soils and can be related to its saturated value b the soil-water characteristic curve (Stankovich and Lockingtom 1995). Modeling the infiltrating water through soils tpicall requires such a functional representation of soil hdraulic properties (Brook and Core 1964). This stud applies the concept of a constant hdraulic conductivit to the potential flow model b which the movement of the wetting front can be predicted and the saturated soil volume underneath the basin can be quantified. At a basin site, the potential flow model provides a simplified and useful approach to understand the soil constraints for the design and a quantifiable basis for site evaluation and alternative comparison. Infiltration Basin esign b r. James Guo 1

CONVEYANCE CAPACITY IN SOILS As illustrated in Figure 1, the infiltrating water begins with a vertical downward velocit through the unsaturated zone underneath the basin. As the soil water content increases, the diffusive nature of the wetting front results in flow movements in both vertical and lateral directions. As soon as the seepage flow reaches the local groundwater table, the soil medium beneath the basin becomes saturated and the seepage flow radiall disperses into groundwater. Although man studies used the concept of potential function to investigate the vertical seepage flow and the associated water mounding effect (Hantuch 1968, Griffin and Warrington in 1988, Mconald et al. 1984), this stud applies stream function to describe the movement of the seepage flow through the soil medium. With the consideration of vertical and radial movements, the potential flow model using stream function is developed for the infiltrating flow under a circular basin as (Guo, 1998 and 001): f ψ π r (1) in which ψ stream function, f infiltration rate, vertical distance for infiltrating flow underneath the basin, r radius of wetting front, and vertical distance above the groundwater table. Figure 1 Illustration of Infiltrating Water The phsical meaning of stream function is the cumulative discharge. For this case, the values of stream functions around the bottom of the basin represent the cumulative release from the basin. The streamline through Point (, ) must have a stream function equal to the total release from the basin as: Infiltration Basin esign b r. James Guo

ψ q fπ () c in which q infiltrating volume rate, basin radius. Between the bottom of the basin and the cross section at (r,) in Figure 1, Eq 1 satisfies the principle of continuit and also describes the growth of the wetting front. Equating Eq to Eq 1 ields r (3) Appling Eq 3 to Point (R,H) on the groundwater table in Figure 1, the radius of the recharging circle is defined as: R (4) H erivatives of Eq 1 with respect to and r represent the velocit components in the flow field as: u f r (5) v f (6) Under a stead state, the flow rate is constant through all sections in Figure 1. Along the vertical direction, the hdraulic gradient, i, can be approximated b unit, i -1 (downward) when the soil suction is ignored (Morel-Setous al et. 1990). According to the arc's law, the recharging flow velocit to the groundwater table is: v q πr K (7) in which K hdraulic conductivit in the vertical direction. Eq 7 must agree with the vertical velocit described b Eq 6 at H. Setting Eq 7 equal to Eq 6 ields: λ H (8) and f λ (9) K The recharge flow radiall disperses into an upper thickness of the aquifer, with much almost stagnant water in the deeper portion of the aquifer (Bouwer et. al. 1999). In this stud, such an active flow depth, H, below the initial groundwater table is estimated b the epuit-forchheimer equation as: K rπ q ψ c ( H ) (10) ln( R / R ) o Infiltration Basin esign b r. James Guo 3

in which K r hdraulic conductivit in the radial direction. In general, storm water infiltration basins are small in size and operated with a short loading period. Unlike the long term recharging basin, the height of a water mound under a small storm water retention basin decas toward the initial groundwater table. Under this condition, Eq 10 can be an approximation near the edge of the area of recharge, i.e. Point (R,H) in Figure 1. Eq 10 divided b the effective flow depth, H, ields the radial flow velocit that must be equal to the horizontal velocit described b Eq 4. As a result, the active flow thickness of aquifer is derived as: H λ ln λ r ( λ 1) (11) And r f K λ (1) r In practice, the value of H is the smaller one between Eq 11 and the available thickness. Aided b Eq 8, the vertical flow depth,, underneath the basin is λr ln λ λ (13) ( λ 1) To enhance the effectiveness of storm water disposal, the design infiltration rate is often chosen to be greater than the hdraulic conductivit, i.e. λ >1 or λ r >1. However, the seepage flow underneath the basin depends on not onl the soil hdraulic conductivit but also the subsurface hdraulic gradient. To sustain a stead state, Eq s 11 and 13 prescribe the required saturated depths in order to provide sufficient hdraulic gradients. STORAGE CAPACITY IN SOILS Under a stead state condition, the vertical movement of the wetting front is within the soil volume outlined b the streamlines. Aided b Eq 3, the incremental volume, dv, due to a movement of, d, at depth,, can be calculated as: dv πr d (14) Aided b Eq 3, Eq 14 is integrated from to H as: V s πr o ln( ) H (15) in which V s saturated soil volume between the basin and the groundwater table. uring the saturation process, the soils begin with an initial water content, θ, and end up with the final water content equal to the porosit, θ s. As a result, the soil storage volume beneath the basin is: V ( θ θ ) V (16) W s s When the basin stores storm water more than the soil storage capacit beneath the basin, the draining process begins with the storage process to saturate the soil and then continues with the conveance process to recharge the groundwater. Infiltration Basin esign b r. James Guo 4

ESIGN EXAMPLE The challenge in storm water retention design is to cope with the huge water volume. Both soil conveance and storage capacities depend on the vertical distance between the basin and the local groundwater table. If the basin stores a water volume less than the subsurface soil storage capacit b Eq 16, the draining process is essentiall to saturate the soil medium; otherwise the effectiveness of draining relies on the subsurface geometr below the basin. It is necessar to make sure that adequate hdraulic gradients exist to sustain the infiltrating flow rate. This paper presents an example to demonstrate how to determine the storage capacit at a site. The surface infiltration rate for the example is 1.5 inch/hour and the soil hdraulic conductivit is 1.0 inch/hour. The soil porosit is 0.35 at the site and the initial water content is 0.10. Assuming that the underground environment is homogenous and isotropic, therefore λ r λ 1.5 for this case. B Eq s 11 and 13, the vertical flow distance,, and the groundwater active thickness, H, are calculated as: H 0.74 0.49 (17) (18) The vertical distance, Y, between the basin and the local groundwater table is the difference between and H as: Y R H o 0.5 (19) At the basin site, the vertical distance, Y, to the groundwater table is known. Table 1 is a comparison among the cases with a different vertical distance, Y. To be conservative, the basin storage volume shall not exceed the soil storage capacit beneath the basin (Guo and Hughes 001). Otherwise, the soil medium has to serve as a conduit to continuousl pass the seepage flow and ma develop a water mound to back up the flow sstem. Considering the soil pore storage volume as basin volume, the water depths are calculated in Table 1. This method agrees with the general practice that infiltrating basins shall be wide, flat, and shallow in depth. Vertical Basin Vertical Groundwater Soil Soil Water istance Radius Flow Active Saturation Storage epth istance Thickness Volume Capacit In Basin Y Ro H Vs Vw feet feet feet feet cubic ft cubic ft feet Eq 19 Eq 17 Eq 18 Eq 15 Eq 16 5.0 0.0 14.8 9.8 7663.1 1915.8 1.5 10.0 40.0 9.6 19.6 61305.1 1536.3 3.05 15.0 60.0 44.4 9.4 06904.7 5176. 4.57 Table 1 Soil Conveance and Storage Capacities for λ r λ 1.5 Infiltration Basin esign b r. James Guo 5

CONCLUSIONS Urban water environment is an increasing concern to man metropolitan areas. Retention basins are an effective approach to reduce pollutant levels in storm runoff. Considering the uncertainties in estimating surface and subsurface hdrologic parameters, a basin is often designed with insufficient information. After installation, the basin ma not be maintained as scheduled. As a result, it is necessar to appl a conservative approach to design a storm water storage basin. In practice, the loose soil texture on the surface tends to have a higher infiltrating rate than the soil conductivit below the basin, i.e. λ r >1.0 or λ >1.0. In order to sustain the continuit between the surface and subsurface flows, this paper presents a method, Eq s 11 and 13, to determine the minimum vertical depth required underneath the basin. If the vertical distance from the basin bottom to the groundwater table is greater than required, the subsurface geometr beneath the basin is able to sustain the infiltrating water. Otherwise, water mounding ma back up the soil-flow sstem and standing water appears in the basin for a prolonged draining time. The operation of soil infiltration is a transfer of water volume from the surface basin to the underground. In practice, the soil medium is likel to be nonhomogeous and nonisotropic. With man uncertainties in the assessment of soil conveance capacit, it is advisable that the basin is designed with a storage volume not to exceed the available pore volume in the soils b Eq s 15 and 16. As a rule of thumb, one foot of water ma fill up the pore volumes in four feet of soils. The potential flow model is applicable to the designs of storm water retention basins, highwa infiltration trenches, infiltration ponds, percolation pavements, vegetable beds etc.. The potential flow model does not require detailed site specifics. It is simple in use and provides reasonable assessments on water mounding impacts. It can be a useful tool at the planning stage when little design information is available, but it does not replace the necessit of more complicated groundwater flow modeling studies to refine the predictions. REFERENCES Bouwer, H, Back, J.T., and Oliver, J.M. (1999), "Predicting Infiltration and Ground-water Mounds for Artificial Recharge". ASCE J. of Hdrologic Engineering, Vol 4, No. 4, October, pp 350-357 Brooks, R.H., and Core, A.T. (1964). "Hdraulic properties of Porous Media." Hdrologic Paper No. 3, Colorado State Universit, Ft. Collins, Colorado. Ferguson, Bruce K., (1990). "Role of the Long-term Water Balance in Management of Storm Water Infiltration," J. of Environmental Management, Vol 30, pp 1-33. Griffin,.M. Jr., and Warrington, R.O. (1988). "Examination of - Groundwater Recharge Solution.", ASCE J. of Irrigation and rainage Engineering, Vol. 114, No. 4, Nov., pp 691-704 Guo, James C.Y. (00). Overflow Risk of Storm Water BMP Basin esign, ASCE J. of Hdrologic Engineering, Vol 7, No. 6, Nov/ec. Guo, James C.Y. and Urbonas, Ben. (00). Runoff Capture and eliver Curves for Storm Water Qualit Control esigns, ASCE J. of Water Resources Planning and Management, Vol 18, Vo. 3, Ma/June. Guo, James C.Y. (001). "esign of Circular Infiltrating Basin under Mounding Effects" ASCE J. of Water Resources Management and Planning, Vol 17, No. 1, Jan/Feb. Issue, pp 58-65. Guo, James C.Y. and Hughes, William (001). "Storage Volume and Overflow Risk for Infiltration Basin esign", ASCE J. of Irrigation and rainage Engineering, Vol 17, No.3, Ma/June. pp 170-175. Infiltration Basin esign b r. James Guo 6

Guo, James C.Y. (1998). " Surface-subsurface Model for Trench Infiltration Basins", ASCE J. of Water Resources Management and Planning, Vol 14, No. 5, Sep/Oct. Issue, pp 80-84. Hantuch, M. S. (1967). "Growth and eca of Groundwater-mounds in Response to Uniform Percolation." Water Resources Res, Vol 3, pp 7-34. Mconald, Michael G., and Harbaugh, Arlen, (1984). "A Modular Three-dimensional Finite-difference Groundwater Flow Model", U.S. epartment of the Interior, USGS, National Center, Reston, Virginia. Morel-Setous, H.J., Miracapillo, C., and Abdulrazzak., M. J. (1990). "A Reductionist Phsical Approach to Unsaturated Aquifer Recharge from a Circular Spreading Basin." Water Resources Research., Vol 6, pp 771-777. Stankovich, J.M., and Lockington,.A. (1995). "Brook-Core and Van Genuchten Soil-water -retention Models." ASCE J. of Irrigation and rainage Engineering, Vol. 11, No. 1, Jan/Feb., pp 1-7. Infiltration Basin esign b r. James Guo 7

Infiltration Basin esign b r. James Guo 8