Outdoor + Switchgear, Walk-in Equipment Buildings Low & Medium Voltage NEMA 3R

Similar documents
Power Zone Center. Your solution for power distribution and control systems

GE EQUIPMENT CENTERS APPLICATION CONSIDERATIONS

Power Electronics, Inc. Packaged Equipment Center Standard Construction and Design Features

SECTION INTEGRATED POWER ASSEMBLY (IPA)

Equipment Specifications Low Voltage. Active Harmonic Filter

Arc Resistant Switchgear & Integrated Factory Assembled Buildings

Electrical Houses. Coordinated. Coordinated Electrical Houses Integrated Power Assemblies IPAs Contents

Power Control Distribution Building (PCD) Technical Specification General Purpose (Non-Hazardous) Environment

INC Pre-Assembled Structures

SECTION PARK NON-SEGREGATED BUS SPECIFICATION

Power Control Distribution Building (PCD) Technical Specification Corrosive Environment

STARRCO M O D U L A R O F F I C E S Y S T E M S S P A C E S O L U T I O N S F O R T O D A Y A N D T O M O R R O W

SECTION MOTOR CONTROL CENTER

Place & Connect Pumping Stations

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components

Superior Pre-engineered Modular Systems

Electrical Houses. Coordinated. Coordinated Electrical Houses Integrated Power Assemblies IPAs Contents

MANUFACTURING TECHNICAL INSTRUCTIONS SAFETY Subject: DESIGN, MAINTENANCE AND INSPECTION OF SECONDARY ELECTRICAL DISTRIBUTION SYSTEMS

Noise Control. Commercial, Industrial, and Environmental Products and Solutions.

CONTENTS. B. System Design and Performance Requirements

Power Control Distribution Building (PCD) Technical Specification Classified Environment

PORTABLE ELECTRICAL SHELTERS

Important Considerations for Specifying MV Mining Switchgear Western Mining Electrical Association Edmonton, Canada June 13, 2008

INDEX. Page SECTION 1.0: SCOPE Toronto Hydro Requirements Ontario Electrical Safety Code 1 SECTION 2.0: PURPOSE 1

1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %

B. Accept materials on site in original factory packaging, labeled with manufacturer s identification.

SECTION FIELD PANELS

SERIES 0 BIDDING REQUIREMENTS AND CONTRACT FORMS

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

INSTALLATION MANUAL KOCH

MOBILE SUBSTATIONS TRAILER AND SKID. tgood.com. Energy, Fast!

Power IT Compact Secondary Substations, CSS. Technical catalogue for sheet steel substations

SUGGESTED SPECIFICATION for Low Voltage (600V) Generator Paralleling Switchboard

Integrated Power Assemblies - Electro/Centers

Watercrest - Sand Hill - Columbia, SC TABLE OF CONTENTS PROCUREMENT AND CONTRACTING REQUIREMENTS

SECTION METAL-ENCLOSED BUS MEDIUM VOLTAGE

Packaged Systems Building Specification

VERTEX. different. Molded Fiberglass Composite Shelters

METAL ENCLOSED BUS SOLUTIONS

A. Access doors and frames are part of an access door and frame allowance.

a) Line and load compartments must be separated by a stable barrier.

Whitley Shower Locker Toilet Facilities

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition

1.0 In addition to the requirements previously presented herein, each specification shall contain the following general information:

ADDENDUM 2 - JULY 14, 2015

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

N-SERIES: NTH2700 SPECIFICATIONS Tubular Composite Top Hung Sliding Door System

Overbrook Theater / Fruenthal Foundation Art Center. 1.0 Total Points % 2.1 Building Exterior Elements %

Vertical Aeroponic Portable Indoor Farms

ECOCASITA PLUS63. Drawings. Outside elevation example. Ground floor plan example. Page 1 of 27

1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %

PHYSICAL BARRIERS MACHINE GUARDS ROBOTIC WORK CELLS PERIMETER OR AREAS GUARDS PHYSICAL BARRIERS

LTH3700, HOLLOW METAL SLIDING FIRE DOOR

Details of technical leaflets/write-up on various pieces of equipment.

Vertical Aeroponic Portable Indoor Farms

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

SECTION ENCLOSED BUS ASSEMBLIES

1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %

VOLUME 4 DIVISION SPECIFICATIONS

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

SECTION to 5000 AMPERE PLUG-IN AND FEEDER BUSWAYS - SPECTRA. A. Low-Voltage Plug-in Busway to 5000 ampere, 600 VAC

EXTRA DURABILITY BY DESIGN TO LOWER YOUR LIFECYCLE COST

Power IT Compact Secondary Substations, CSS. Technical Brochure

High Light. Motors are fully submersible Pumps can handle up to 2 spherical solids Indoor and outdoor installation Easy installation and removal

A new market trend. E-House. Make the most of your energy

SECTION PRE-ENGINEERED MEMBRANE STRUCTURE

SECTION PART 1 GENERAL

Permit Application Commercial / Industrial / Multi-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

"SRMZ" ROOFTOP PACKAGED MULTIZONE UNITS Self Contained Single Package Units 17.5 to 43 Ton Cooling Capacities

DIVISION MEDIUM VOLTAGE VAULT DESIGN Contents

SIEMENS. Instructions. Outdoor Metal Clad Switchgear. Installation Assembly OGM&SGM SG kV and 15kV. www. ElectricalPartManuals.

Division 00 Procurement and Contracting Requirements

INTRODUCTION MOBILE OFFICES

Built to Order. Stile. Frames. Section Contents. Profiles. Elevations. Double Egress Frames Pocket Frames

SECTION AWNINGS

SECTION DUMBWAITERS

Specifications for RM Products Ltd. Pre-Assembled & Unassembled Fiberglass Buildings

POWER BOX ENCLOSURES. Product Catalog June 2017

L-SERIES: LTH3900 SPECIFICATIONS Stainless Steel Hollow Metal Sliding Fire Door System

Coordinated Outdoor Houses Electro/Centers

A. Provide and install a factory made, wood framed, storage building. B. Building Construction Type: IBC Type V-B Wood Frame.

New Main Hospital, Site Park, and Underground Garage Construction Progress Update #16

Permit Application Commercial / Industrial / Mutli-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE (Form #2)

Phone Toll-Free Fax

MODULAR COLD STORAGE SPACE. USS John Stennis DESIGN CONSTRUCTION HARDWARE FEATURES OPTIONS

1. Section , Gas and Vacuum systems for Laboratory and Healthcare Facilities

ASSE International Product (Seal) Listing Program. ASSE Outdoor Enclosures for Fluid Conveying Components

AUTOMATIC VERTICALLY RETRACTABLE Skyfold Mirage ACOUSTIC INTERIOR GLASS WALL Section Page 1 October 2017

SECTION ENCLOSED BUS ASSEMBLIES

Utility Cabinet System (UCS)

The exterior skin of the enclosure shall be manufactured from thick H32 aluminum which has been powder coated with polyester powder.

SECTION FIBERGLASS REINFORCED PLASTIC (FRP) ENCLOSURE

City of Omaha Plans and Permits Commercial Alterations and Conversions Building Permit Submittal Checklist

OPERATING PROCEDURE NO. 310

Section BUILDINGS, SHELTERS, ENCLOSURES

CLCF Climate Changer for comfort applications. Next generation air handling performance from Trane

B. Provide equipment complying with this specification and manufactured by one of the following:

SECTION SECONDARY UNIT SUBSTATIONS

Transcription:

Outdoor + Switchgear, Walk-in Equipment Buildings Low & Medium Voltage NEMA 3R Product Brochure www.apt-power.com 433 N. 36 th Street PROVIDING A COMPREHENSIVE Lafayette, IN 47905 www.apt-power.com 433 North APPROACH 36 th Street, TO Lafayette, RELIABLE Indiana POWER 47905 Tel. 765-446-2343 765-446-2343

1 Features & Benefits Low or Medium Voltage Paralleling, Distribution & Motor Control Applications Packaged in a modified and reinforced 20 foot or 40 foot ISO container, or in a custom equipment building to meet your exact needs. Walk-in switchgear isle is constructed as one piece of custom building or enclosure to simplify onsite installation. All equipment inside is factory installed and wired. Available with insulated walls, floor and ceiling. Optional aluminum diamond plate provides a safe, long lasting, easy to clean floor. Complete with internal lighting (AC and/or DC) and convenience receptacles. Heating and/or cooling units designed for its operating environment. Separate rooms when appropriate for the application (transformer compartment, etc.) Rugged, durable, weather resistant construction for the worlds harshest environments. www.apt-power.com Long life, no maintenance aluminum, insulated walls and ceiling. For operator safety and a finished look and feel, all internal wiring is run in enclosed ducts, or conduit. Utility metering compartments can be integrated in the switchgear. Configurable for a wide range of applications: o Automatic and/or manual generator paralleling switchgear. o AC or DC variable speed motor control. o Power distribution switchgear. Side, top or bottom cable entry and exit. o Power and control quick connect receptacles are available. Optional site control and monitoring: o Modbus serial or Ethernet communications. o SCADA computer systems. o Master control panels. 433 North 36th Street, Lafayette, Indiana 47905 Tel. 765-446-2343

2 Outdoor Walk-in Equipment Building Construction Insulation Walls and roof insulated to customer specifications Siding & Roofing Multi-Rib panels with a Kynar 500 finish Roof & Walls Galvanized steel structural frame engineered to building codes in your area Interior Wall 16GA Aluminum or as specified Personnel Doors Insulated steel doors with panic hardware and stainless steel hinges Floor ¼ steel plate with optional non-skid additive Optional Cutouts Cutouts in base plate for cable access Insulation Optional spray foam insulation in base Shipping Split Building can be split for shipping if required *HVAC Optional heating and cooling to meet customer specifications Exterior Doors Optional equipment access doors Base ASTM A36 structural steel members continually welded and engineered for lifting and placing building with equipment installed

3 ++ Outdoor Switchboards Low Voltage & Medium Voltage (Included NEMA 3R Roof Not Pictured) APT also offers medium voltage (bottom), combination low & medium voltage (middle), and low voltage (top) switchgear in an outdoor NEMA 3R non walk-in arrangement in a variety of colors

4 Outdoor Walk-in Equipment Buildings Low Voltage & Medium Voltage APT s outdoor walk-in switchgear offers a clean and safe work environment in an optional climate controlled aisle

5 ISO Container Based Switchgear

6 Dimensional Drawings Typical Dimensions & Layout of Low Voltage Outdoor Switchboards

7 Dimensional Drawings Typical Dimensions & Layout of Medium Voltage Outdoor Switchboards

1 18 Dimensional Drawings Typical Dimensions & Layout of Low Voltage Walk-in Building

9 Dimensional Drawings Typical Dimensions & Layout of Medium Voltage Walk-in Building