January 29, This report must be reproduced in full, unless SwRI approves a summary or abridgement.

Similar documents
SOUTHWEST RESEARCH INSTITUTE

Addendum to the Hydro International s Downstream Defender Conditional Interim Certification

Indoor Air Quality and Mechanical Ventilation (Page 1 of 5)

Understanding the Use of Atomizing Gas to Shape and Adjust Velocity of Ultrasonic Atomizer Spray

The Use of Walnut Shell Filtration with Enhanced Synthetic Media for the Reduction and/or Elimination of Upstream Produced Water Treatment Equipment

Air Pollution Technology Fact Sheet

UFR+L FILTER REGULATOR + LUBRICATOR

Capability of the Aqua-Swirl Concentrator to Remove Trash from Stormwater Runoff

SAF Filters. The automatic self-cleaning filter - suitable for more applications than ever.

Dan Deatsch Thompson Environmental Consulting

0.01 Micron Membrane Filters

F-Series 1 Elements Performance Validation

SafidLouvers. Sand Trap Louver STL STL STL Construction Standard STL STL STL Optional Extras

ULTRA-FILTER COMPRESSED AIR FILTERS DF SERIES. Compressed Air & Process Filtration

A pilot scale study of pulse-jet cleaning of a rectangular bag filter system: optimization of operating parameters

Rainsmart Ellipse Tank O & M Guide Manual for Inspection Row

Environmental Control System Testing and Performance Evaluation of a Transport Aircraft

flow rates filtration degrees water for cleaning minimum operating pressure micron less than 1% of the total flow

Conditional Interim Certification Findings

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

AIR FILTERS: REAL WORLD PERFORMANCE

Background Information on Material Tests

AS-H Iso-Disc Cloth Media Filter

Validation of Sterilizing Grade Filters

Peerless Europe. Separation and Filtration

CleanMist and FEF. Centrifugal filters for oil mist and electrostatic filters

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS

Particle Sample Tube Lengths for Pharmaceutical Monitoring. Version 01. Rev 01.

EFFECTIVE AND EASILY MAINTAINED TREATMENT SOLUTIONS

Screening, Definition: The unit involved is called a screen.

AIR TREATMENT BREATHING AIR PURIFIERS. DBS Series

Brian M. King P.E., Power & Industrial Services Corp. 821 NW Commerce Dr, Lee s Summit, MO ,

OZONE REMOVAL BY CHARCOAL FILTERS AFTER CONTINUOUS EXTENSIVE USE (5 TO 8 YEARS)

RETROFIT SOLUTIONS. For Gas Turbines And Rotating Machinery

AIR TREATMENT BREATHING AIR PURIFIERS. DBS Series

Fabric Filtration. Typical Dimensions Dirty gas flows into page 11/6/2015. EVE 402 Air Pollution Generation and Control. Chapter #5 Lectures (Part 6)

Prepared for. Superior Products International II, Inc W. 78th Street Shawnee, Kansas Prepared by

This document is a preview generated by EVS

EBS Filters. The largest automatic self-cleaning filter for fine filtration. features: up to 7200 m³/h (32000 US gpm) less than 1% of the total flow

Steven L. Alderman, Michael S. Parsons, and Charles A. Waggoner. Institute for Clean Energy Technology, Mississippi State University

BAG FILTERS (BAGHOUSES)

PERKFILTER. Design Guide

Specifications. 304 Stainless Steel Mesh Screen. Specifications

IMPACT OF THE SEMCO ANTI-STICK FACE COATING ON THE COLLECTION AND CLEANING OF ENVIRONMENTAL TOBACCO SMOKE FROM THE WHEEL SURFACE RESEARCH FINDINGS

FIELD PERFORMANCE TESTING OF IN-CANOPY CENTER PIVOT NOZZLE PACKAGES IN KANSAS. Danny H. Rogers, Gary A. Clark, Mahbub Alam, Kent Shaw 1

Prepared by. RTI International ETS, Incorporated. EPA Cooperative Agreement CR

ASME Cavitation and Multiphase Flow Forum, FED-Vol. 153, Washington, D.C., June 1993.

Joint Committee Issue Paper

Compressed Air Filters Sample Filters

North American Filter Corporation

The University of Liège Wind Tunnel Facility

Valve Nest Filter with Time Clock Control Installation and Operation Manual

Demonstration of Pulsed X-ray Machine Radiography as an Alternative to Industry Radiography Cameras, Demonstration Pilot Project

Betafi ne PPG Series

Assessment of Technology Readiness Level of a Carbon Dioxide Reduction Assembly (CRA) for Use on International Space Station

Intake Housing and Components Route Map and Summary. Gas Turbine Air Treatment Decision Guide

Space Conditioning Systems, Ducts, and Fans (Page 1 of 6)

High Efficiency Liquid-Solid Separators

The Separator. Scope of Delivery. The New Definition of Purity for Your Medium. Our Filter Systems Protect. Separator (SPR / BA) Multi-Separator (M)

Engineering Excellence

1. Overview 2 2. Definitions 2 3. Laboratory Testing Criteria 2. A. Laboratory Qualifications 2. B. Analysis of TSS Samples 2. C.

DEKATI EJECTOR DILUTER IN EXHAUST MEASUREMENTS V2.11

Compressed Air Filters. Particulate, Moisture, and Oil Removal scfm.

Forced Draft Decarbonators. Degasification

COIN. Flow Meters. Segmented Wedge. Your First Choice in Intelligent Flow Management...

Heat Load Calculation for the Design of Environmental Control System of a Light Transport Aircraft

Preliminary Field Evaluation of EPA Method CTM-039 (PM2.5 Stack Sampling Method) Michael D. Buser and Derek P. Whitelock

Protecting Membranes Boosts Benefits

CIRRUS MAGNETIC FLOW METER CLA1-MF

Determination of the filtration performance of air filter CD408/34.5/171 according to EN 779:2002

Space Conditioning Systems, Ducts, and Fans (Page 1 of 6))

FILTERS. specifically designed for Ballast Water Treatment TECHNICAL SPECIFICATIONS. Vol. 2

June 30, Jay Holtz, P.E. Director of Engineering Oldcastle Precast, Inc SW Macadam Ave., #376 Portland, OR 97239

Service and installation must be performed by a trained/experienced service technician.

METER SELECTION FOR VARIOUS LOAD REQUIREMENTS. Edgar B. Bowles, Jr. Southwest Research Institute 6220 Culebra Road San Antonio, TX USA

Test Report for Enclosure Protection Testing of Enclosed DC Isolator to AS60529:2004

Kogan Creek Power. Condenser. Contents. Update For ACC User Group. Kogan Creek Power Station and its Air

Spider-Web. designed to exceed. Gas Turbine Systems

SB-460D PRODUCT CATALOG

Aerators. Aeration and Gas Stripping

Electronic Regulator & Proportional Valve

Texas Gas Association

2008 Beltwide Cotton Conferences, Nashville, Tennessee, January 8-11, 2008

Validation Guide USTR 2114 (2) Validation Guide for Pall Emflon PFR Filter Cartridges

Contact person Date Reference Page Tobias Eriksson P (2) Energy Technology

Self Cleaning HEPA Filtration without Interrupting Process Flow

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Industrial Pretreatment WT - Intakes

Compressed Air Filters. Particulate, Liquid, and Oil Removal ,250 scfm. kaeser.com

Experimental and Computational Study of a Water Wash Spray Injection

On-line determination of particle size and concentration (solids and oil) using ViPA Analyser - A way forward to control sub sea separators

Revisions to the Residential Standards and ACM Calculations. June 13, 2007 Bruce Wilcox, P.E.

CHAPTER 1 INTRODUCTION

MEASURING THE WATER TEMPERATURE CHANGES THROUGHOUT THE ABRASIVE WATER JET CUTTING SYSTEM

NITROGEN SERIES COMPRESSOR SYSTEMS

CFD Modeling of Crankcase Inertial Oil Separators. Arun P. Janakiraman Anna Balazy Saru Dawar

Filtration Applications for the Power Generation Industy

Dynamic Imaging Principle OIW/WIO Analysis

EFFECT OF DESIGN FACTORS ON THERMAL FATIGUE CRACKING OF DIE CASTING DIES

Mist eliminators for Flue Gas Desulphurization

Transcription:

S O U T H W E S T R E S E A R C H I N S T I T U T E 6220 CULEBRA ROAD POST OFFICE DRAWER 28510 SAN ANTONIO, TEXAS, USA 78228-0510 (210) 684-5111 www.swri.org January 29, 2013 ISO 9001 Certified ISO 14001 Certified S&B Filters 15461 Slover Ave Fontana, CA, 92337 This report must be reproduced in full, unless SwRI approves a summary or abridgement. Subject: Letter Report, Test Results, Southwest Research Institute (SwRI ) Project No. 08.17765.05.001, Spray Removal Testing of 75-5064 Intake with AS-6 Scoop Reference: S&B Filters P.O. No. P3613 Dear Mr. Van Gompel: This report presents results of water spray removal testing conducted on a 75-5064 Intake (with white filtering media) with AS-6 Scoop configuration provided by S&B Filters for evaluation. Testing was conducted in accordance with SAE J2554, Engine Intake Air Separation Test Procedure, APR2003. spray removal testing was accomplished at 435 scfm, as specified. Proper droplet size and flow delivery were achieved by nozzle selection and pressure control. The spray nozzle was sized to provide a spray with a median volume diameter (MVD) of 0 microns, based on nozzle performance specifications. The MVD is a value where 50% of the total volume (or mass) of liquid sprayed is made up of drops with diameters larger than the median value and 50% smaller than the median value. The MVD and the actual droplet size distribution (DSD) were not measured. For the specified airflow rate, SAE J2554 called for a water feed rate of 500 ml/min. This testing was accomplished, using the same general experimental arrangement and test protocol as used in previous scoop testing where the fender vent remained open and the water spray was aimed horizontally under the scoop, as illustrated in the S&B schematic shown in Figure 1. The general test arrangement is shown in Figure 2. Test results are given in Tables 1 and Figure 3 and 4. Table 1 gives quantitative results in term of pre-test airflow resistance at rated flow, and water spray collection and penetration. Figure 3 shows pre-test airflow resistance as a function of flow rate, and Figure 4 shows general SAN ANTONIO, TEXAS HOUSTON, TEXAS ANN ARBOR, MI WASHINGTON, DC

SwRI Report, Project No.08.17765.05.001 Page 2 of 7 photographs taken during and after testing. While SAE J2554 is primarily intended to measure separation efficiency, it is apparent in this case that the parameter of most importance is water penetration to the upper filter unit and beyond. In particular, the target for allowable penetration is zero, since the filter should remain dry during vehicle operation in all weather and road conditions. No water penetrated the unit and only a trace of water (by weight, none visible) was retained by the filter. When the airflow was turned off, a very small amount of water remained on the inner walls of the scoop. Table 1. Spray Penetration and Collection: S&B 75-5064 Intake (with white filtering media) with AS-6 Scoop, with Fender Vent Open; 0 µm Mean Volume Diameter (MVD) Spray (Single, Spray Systems Co. 1/8 G-1, 0.031" Dia., Full Jet Nozzle at 24 psi,); Spray Presented Laterally under Scoop; Unit Airflow: 435 scfm. Configuration Fender vent open Test Airflow Rate, scfm* Tests conducted: Jan 2013 Pre-test Restriction, "of water Penetrating Unit, % (a) Penetrating Scoop Section, % (b) Retained by Upper Unit/ and by Filter and Outlet Tube, % (c) Retained by Filter/ Outlet Tube, % (c) Collected on Scoop walls, % (d) 435 5.70 0.0 0.16 0.16/0.07 0.07/0.00 0.32 *cfm At 20ºC and 101.3 kpa wt.of water collected downstream of unit a. penetration wt.of water collected downstream of scoop section b. penetration wt.of water collected in upper unit/and by thefilter and outlet tube c. retained wt.of water collected on scoop walls d. retained

SwRI Report, Project No.08.17765.05.001 Page 3 of 7 It is important to understand the above terminology. penetrating the scoop section is the amount of water presented to the upper filtration section, as a percent of the total water collected during the test. retained by the upper unit is the amount of water retained in the filtration section (filter and filter housing area) as a percent of the total amount of water collected during the test run. The amount of water collected by the filter is also based on the total amount of water collected during the test run. The total amount of water collected includes water collected in the downstream catch basins. It is also important to note that all testing was conducted under suction only, and with the vent open, only a portion of the air enters the unit through the scoop. It is most likely that a better simulation would include ram air below the inlet in addition to the spray stream. This is doable, but would add some complexity to the test setup and testing protocol. Figure 1. S&B Schematic for Testing of 75-5064 Intake with AS-6 Scoop

SwRI Report, Project No.08.17765.05.001 Page 4 of 7 Figure 2. General Test Arrangement for 75-5064 Intake (with white filtering media) with AS-6 Scoop (top row: airflow testing; other rows: water spray testing)

SwRI Report, Project No.08.17765.05.001 Page 5 of 7 Figure 2. General Test Arrangement for 75-5064 Intake (with white filtering media) with AS-6 Scoop (top row: airflow testing; other rows: water spray testing) (Continued) 14 Restriction as a Function of Airflow Rate: S & B 75-5064 Intake with AS 6 Scoop; Tested per ISO 5011, at 3.5" dia Downstream Piezometer, without Upstream Ducting 12 With, fender vent open Restriction - inches of water 10 8 6 4 2 0 0 200 300 400 500 600 700 800 Airflow Rate - scfm (20 C, 101.3 kpa) Figure 3

SwRI Report, Project No.08.17765.05.001 Page 6 of 7 Figure 4. Some General Photographs during and after Testing of 75-5064 Intake (with white filtering media) with AS-6 Scoop

SwRI Report, Project No.08.17765.05.001 Page 7 of 7 Figure 4. Some General Photographs during and after Testing of 75-5064 Intake (with white filtering media) with AS-6 Scoop (Continued) If you have any questions concerning the test program or the results, please do not hesitate to contact me at (210) 522-2626 during normal business hours. For your convenience, our facsimile number is (210) 522-5720 and my e-mail address is mtreuhaft@swri.org. Submitted by: Approved by: Martin B. Treuhaft, Manager Filtration & Fine Particle Technology Gary Bessee, Director Fuels & Lubricants Technology Department Fuels & Lubricants Research Division