Design. Boral CinemaZone Fact Sheet. Windows. Acoustic sealants. Sound absorptive panels. Ventilation. Floor coverings. The vision.

Similar documents
SOUNDCONTAINMENT. for outstanding. home theatre

Acoustic Design Criteria

appendix 19 acoustic insulation requirements

20 THINGS YOU NEED TO KNOW ABOUT LOFT CONVERSIONS

Fire resistance and acoustic properties

Airport Vicinity Acoustic Insulation

QUIET ZONE MODULAR BROADCAST STUDIOS AND VOICE BOOTHS

QUIET ZONE MODULAR BROADCAST STUDIOS AND VOICE BOOTHS

FIRE RATING MATERIAL FIXING NOTES

Standard Practice for Architectural Application and Installation of Operable Partitions 1

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

SOUND INSULATION TESTING SITE READINESS CHECKLIST

General Building Information

Section 10 Residential Zone

RE: AIRCRAFT NOISE ASSESSMENT 42 AND 44 REES JAMES ROAD, RAYMOND TERRACE

Energy Efficiency Requirements 9.36

ROCKWOOL FLEXI Insulation Application Guide

City of High Point Airport Overlay District Noise Level Reduction Design Standards

Approved Document E Technical Design Report

Construction Technology Revision Guide

FACT SHEET 1 SOUND INSULATION GUIDELINES. Key Issues and Considerations. Sound Absorption and Sound Insulation

NOISE IN HIGH RISE BUILDINGS

Communal 51 Ceiling Systems by Vogl

Intertenancy Barrier Systems for Terrace Homes

Ceiling Attenuation Class Systems SYSTEMS 280

Garage Conversions. Technical Issues

Technical Supplement. Internal Fire and Acoustic Rated Floor Solution INTERIORS

Acoustic. . Absorbs sound reduces noise transmission between rooms for a quieter more relaxing home

Leaving Certificate Revision Notes. Airtightness. Potential air leakage paths (the numbered points in section 2.1 give a description for

ENSURING YOUR SCHOOL MAKES SWEET MUSIC: HOW TO STRIKE THE RIGHT NOTE IN SCHOOL ACOUSTICS

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

This report is produced without prejudice.

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation.

LOT 25 Blueleaf Place. Brookfield $511,879 SUMMARY

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW.

Design Standards Brief Section 13 Acoustics

NCC Volume Two Energy Efficiency

URSA ACOUSTIC ROLL URSA GLASSWOOL.

Standard Inclusions for

Acoustic Performance of Light Steel Framed Systems

SoundScreen. Peace and quiet where you need it most

How glass or rock mineral wool works in a wall or floor cavity

84 Symonds Street PO Box 5811 Wellesley Street Auckland 1141 New Zealand T: F:

Island County Noise Zone Maps Adopted with Ordinance C [PLG ] August 12, 2002 Approved by WA State Building Code Council November 26, 2002

CI/SfB l l l Ym1 l (M2) l July Superior 4 in 1 insulation TIMBER FRAME SOLUTIONS GUIDE

ACHIEVING FIRE & ACOUSTIC COMPLIANCE IN MULTIRESIDENTIAL CONSTRUCTION. USGBoral.com

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red

Guidance on U Values from Domestic Heating Design Guide

T-Barrier System. Timber Frame Applications. Satisfying Fire, Thermal and Acoustic Requirements at the Combined Party Wall and Pitched Roof Junction

Wall Linings. As well as complete dry lining solutions we also provide fast-drying parge coat to ensure airtightness,

SubPrimo. subprimo. Acoustic insulation for timber & laminate flooring. Uniclass L5395:N372 EPIC E485:Y45. CI/SfB (43) T (P2)

Insulation - Products

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

SEPARATING WALLS CLASS 1A

Building Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide

Magnesium Oxide Board Corporation CodeMark Certificate of Conformity (CMA-CM40009 (Rev2)) Building Code of Australia Classification Summary

2012 Code Update Training

PLASTERBOARDS PRODUCTS AND APPLICATIONS

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

LABC REGISTERED THERMAL SYSTEMS TO PART L

Construction Studies Theory - Higher Level

LABC RegisteRed thermal systems to PARt L 2006 And 2010 multi-foil insulation And BReAtheR membranes

Typical detail: New roof with breathable underlay

T-Barrier System. Masonry Applications. Satisfying Fire, Thermal and Acoustic Requirements at the Combined Party Wall and Pitched Roof Junction

June Non - Residential New Build Partition walls

INTERTENANCY SYSTEMS 2018

RENDERS ARE INDICATION ONLY. Land. Home size 26sq. 28 Ajay Way, Kurunjang LEGACY 26 $545,500 ACTUAL HOUSE IMAGE PRESENTED BY

Specialists in Acoustic Flooring and House to Flat Conversions

WeatherSmart Air Barrier Installation Guide

Selecting floors and ceilings

Understanding thermal mass

STANDARD MODULAR INCLUSIONS. NOV 2018

Doc Ref: AT_CHECKLIST Title: Residential Air Permeability Checklist Issue: V4

Air & Sound testing in one easy package

Typical Finished Basement Details

LEED for Homes Approved ID Request:

Noise Control Systems Supplement

Measurement of room-to-room airborne sound insulation with an access floor in a dwelling unit of condominium

Building Envelope

Resistance to the passage of sound

Resistance to the passage of sound

USGBORAL.COM SYSTEMS+ INTRODUCTION OUTRWALL BRICK VENEER WALLS EXTERNAL WALLS INNOVATIVE SYSTEMS SOLUTIONS

Measurement of room-to-room airborne sound insulation with an access floor in a dwelling unit of condominium

Fire Safety and Performance of Wood in Multi-Residential and Commercial Buildings. Boris Iskra Forest & Wood Products Australia

ORDINANCE NO The council of the city of El Segundo does ordain as follows. FINDINGS The City Council finds and declares as follows

September Reflex Bearers

Association of Australian Acoustical Consultants Guideline for Commercial Building Acoustics. May 2011

The costs of improving the thermal performance of houses in a cool-temperate climate

ACOUSTIC TREATMENT. 1 Reverberation. Inside a given internally reflective enclosure, the human ear receives:

Wet Areas Using Plasterboard

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

2014 British Columbia Building Code Changes

2010 National Building Code Adoption and Associated Process Changes

Part E robustdetails. robustdetails. September 2015 Update Pack. Dear Colleague,

April Section Internal Walls

Pre-schematic Considerations. Who. What. Where

2003 International Residential Building Code

TIMBER FRAME HOUSING SOLUTIONS

A Handbook of thermal bridging details incorporating aircrete blocks

Transcription:

Windows Like doorways, windows can be a significant source of sound leakage. For maximum isolation, windows should either be removed or built over internally - leaving the house facade unaffected. If natural lighting is required then consider fitting a secondary 10mm glazed window to the internal wall. Thick wool curtains are good for acoustic absorption but not for preventing sound transmission. Ventilation Air movement in a CinemaZone TM room is almost reduced to nil because of the acoustic sealing that makes a room virtually airtight. Some form of mechanical ventilation will be required to improve airflow. Boral recommends fitting a CinemaZone TM room with at least one fan-assisted inlet vent and one exhaust vent. The inlet vent should draw air from an adjoining habitable room or from the outside. It should not draw air from a kitchen, bathroom, toilet or laundry or from a room that CinemaZone TM air is being exhausted into. The exhaust ventilation duct, similar to the inlet duct illustrated in the Construction Fact Sheet (fan optional), may also be fitted to the ceiling. Boral suggests home cinemas achieve at least six air changes per hour, however, this will depend on the volume of the room and the number of people intended to use it. Larger installations may require the advice of an air-conditioning professional. Lighting Light fittings need to be carefully considered as any lining penetration will seriously compromise sound isolation. Recessed downlights should be avoided due to acoustic leakage. Track mounted light fittings fitted to the surface are an effective alternative. An emergency light is a sensible inclusion and may help to overcome a Building Surveyor s objections if it is proposed to remove or build over a window. Acoustic sealants All gaps and floor, wall, ceiling, door, window, vent and service junctions should be sealed with an acoustic filler such as FireSound TM. Sound absorptive panels Sound absorptive panels are made from high quality acoustic absorption materials that improve the listening experience when selectively positioned around the home cinema. They are typically manufactured from compressed fibreglass or foam and can be covered in a wide variety of fabrics, colours and textures. Refer to TecASSIST for retail outlets or construction details. Floor coverings Thick wool carpet over felt underlay is considerably more effective at absorbing sound than thin or synthetic carpets. Polished timber floors and tiles don t perform nearly as well, as they are highly reflective, increase reverberation and have a detrimental affect on sound quality. The vision Home cinemas can include conventional television or powerful projection systems. In both cases, it is important to utilize darker colours such as matt black to obtain the maximum visual contrast and avoid screen reflection. It is often necessary to black out windows, particularly if the cinema is to be used during the day, and consideration should be given to the location and direction of ambient lighting.

Recommended room proportions Height(m) Width(m) Depth(m) Option 1 ratio 1.00 1.14 1.39 Option 2 ratio 1.00 1.28 1.54 Option 3 ratio 1.00 1.60 2.33 As an example, if your ceiling height is 2.7m, using the Option 1 ratio above, the width of the room should be 3.1m (1.14 x 2.7m) and the depth should be 3.8m (1.39 x 2.7m). From Sepmeyer L.W. Computed frequency and angular distribution of the normal modes of vibration in rectangular room, Journal of the Acoustic Society of America, Volume 37, Number 3 (March 1965) Pages 413-423 and extracted from Widescreen Review June/July 1994 pg 65. Stop Board TM and DuctBoard TM are trademarks of Amatek Ltd trading as Insulation Solutions. CinemaZone TM, SoundStop TM and CinemaSpan TM are trademarks of Boral Plasterboard. FireSound TM is a trademark of HB Fuller. For more information on CinemaZone TM or to request the other free fact sheets in this series, call Boral Plasterboard TecASSIST on 1800 811 222 for a fax or email copy or visit the website: www.boral.com.au/cinemazone Performance Sound advice How Boral CinemaZone works Sound and levels * Who it affects * How to control it The Sweet Spot Construct New, extension or conversion - how to build a Boral CinemaZone System Walls Ceiling Floors Doors Windows Lighting Ventilation

The home cinema experience Ask yourself Do I live in a quiet neighbourhood? Do I live in a noisy neighbourhood? Do I have quiet zones in my house? Do I use my sound system late at night? Do I like it loud? Do I live in a high rainfall area? Do I have to comply with local noise restrictions? If you can answer Y E S to any of the above then you need Boral CinemaZone TM. Successful While home cinema can be enjoyed in the family lounge room, for many people a purpose-designed space will be desired. Successful home cinema design is not a matter of chance but instead relies upon scientific data for choosing the correct room proportions and acoustic treatment. In order to achieve the high level of acoustic performance needed for your new home cinema, the following areas need to be addressed: Room Proportions Most rooms are often too small to provide smooth sound, particularly at low frequencies. A room greater than 50m 3 volume is recommended to ensure the best reproduction of bass frequencies. Ideally, the width-to-length and width-to-height room ratios should also be considered. The choice of room size has been simplified thanks to the research of L.W. Sepmeyer who established a direct relationship between the room proportions and acoustic performance. His recommendations (published in the Journal of the Acoustic Society of America) are included at the end of this publication. Sound Isolation CinemaZone TM wall and ceiling systems are required to prevent sound transmission out of and into a home cinema room. CinemaZone TM ceiling systems also minimise the noise created in the room by heavy rain on the roof. Sound Reverberation Sound reverberation in a room is also an important factor and this can be controlled by applying an acoustic absorber to approximately 30% of the wall surface area. Sound Leakage All door, window, vent and service openings need to be sealed to minimise sound leakage. your Reverberation If your intended CinemaZone TM room: has an exposed timber floor has large window areas does not have wool curtains does not have heavy cloth-covered sound absorbent furniture then you need to consider ways of minimising potentially excessive reverberation. Reverberation refers to the persistence of sound in a room after the source of sound has stopped. This persistence is a result of repeated reflections of sound waves that behave like an echo. Long reverberation times produce fuzzy, unclear sounds while short reverberation times result in dead, flat sounds. The ideal reverberation time of 0.3 to 0.4 seconds for a home cinema can be achieved by using sound absorption panels (living rooms typically range from 0.5-1 second). Some experimentation with panel placement will be required and the final positioning will depend on the speaker and seating locations. Experience has shown that seating is best situated at a distance of about 3 or 4 times the screen height, away from the screen.

Council requirements The home cinema is still classified as a habitable room and subject to the usual building regulations, however, due to its special design requirements, consideration should be given to the following: an exemption from natural lighting may be obtained if it can be demonstrated that the room will only be used as a home cinema mechanically assisted ventilation will be required in what is essentially an airtight room the minimum ceiling height of 2400mm may be able to be reduced in certain circumstances exit lighting with battery backup is an important safety feature, especially if there s no natural lighting a smoke alarm the noise impact objectives of the ResCode Standard B24 aim to contain noise that may affect other dwellings in multi-unit developments. Boral Plasterboard recommends contacting a building surveyor regarding regulations and possible concessions before starting construction. Floors It is anticipated that most home cinemas will be constructed at ground-floor level. Houses built on a ground slab have a distinct advantage as the combination of concrete and earth is a good sound insulator. Houses built with a timber floor require additional treatment to prevent a condition known as flanking, where sound travels down through the floor, under a wall and up into an adjacent room. Timber and upper-floor home cinema installations should be referred to the Boral Plasterboard TecASSIST help line on 1800 811 222. CinemaZone External Walls Brick veneer wall in a new or existing building Weatherboard External wall frame External wall frame 100mm 202mm Boral 13mm SoundStop TM 50mm 144mm Timber clad external wall in a new or existing building

CinemaZone Internal Walls CinemaZone TM internal walls can be built in both single or double stud configurations with your choice largely dependent on the available space and construction preferences. Resilient mounted furring channel Nominal 196mm Single stud wall in a new building 247mm Double stud wall in a new building Existing plasterboard Boral 13mm SoundStop TM 131mm Resilient mounted furring channel Double stud wall in an existing building Existing plasterboard Boral 13mm SoundStop TM 80mm Standard Boral plasterboard FireLight TM block wall 50mm Single stud wall in an existing building 116mm Internal masonry wall using Boral FireLight TM bricks in a new or existing building * * N.B. WA customers should contact Midland Brick for the appropriate product from their Special Performance brick range.

CinemaZone Ceilings The structural capacity of an existing ceiling needs to be evaluated before specifying a home cinema installation. Conventional timber pitched roof/ceilings will generally be capable of carrying an additional ceiling load. However, many truss roofs have been designed close to their loadbearing capacity and may need a separate ceiling support system such as the CinemaSpan TM ceiling system. Roof Truss 100mm Existing roof structure. Resiliently mounted furring channel Resilient mounted ceiling 100mm CinemaSpan TM ceiling system 10mm Min Min 20mm. CinemaSpan TM ceiling system Roof Truss BHP 120 Topspan 0.9mm BMT Max height of roof space above CinemaZone TM ceiling CinemaSpan TM is the subject of a patent application and should not be used with other than Boral Plasterboard TM products without the express written permission of Boral Plasterboard. The CinemaSpan TM ceiling system utilizes BHP 120 Topspan 0.9mm BMT sections. CinemaSpan TM joists are to be fixed on to top plates within 50mm of a wall stud or an appropriately sized lintel. For CinemaZone TM installations intended to be positioned below another floor, additional information is available from TecASSIST on 1800 811 222. Doors Maximum span (mm) of CinemaSpan TM joist when spaced at 450mm centres 600mm centres Less than 1.2m 4210 4070 Greater than 1.2m 3620 3540 A door left untreated can seriously compromise the acoustic isolation of a home cinema space. This can be avoided by: forming a sound lock between the cinema room and the rest of the house. fitting the cinema with 40mm solid core doors. fitting cinema doors with acoustic seals such as Raven RP94Si to the top and sides and Raven RP8 to the bottom. A sound lock can be created by fitting a door to both sides of a door jamb. The void formed between the door faces and door stops becomes the soundlock. If this method is adopted, the door jamb will need to be split through the middle of the door stops and a 15mm gap formed. This gap, after filling with an acoustic sealant, will prevent sound being transmitted through the frame.