The impact of Building Automation on Energy Efficiency. Siemens with DESIGO and Synco best in class. Siemens AG, plc, All Rights Reserved

Similar documents
The impact of Building Automation on Energy Efficiency. Siemens with DESIGO and Synco best in class. Siemens AG, 2009 All Rights Reserved

Energy Efficiency. best in class

Smart building for a greener Europe: emerging policy and practise

Can we feel safe in this building?

Desigo. Proven applications sustainably energy-efficient

Application of EN :2017 siemens.com/buildingtechnologies

ENERGETIC MONITORING AND OPTIMIZATION OF A SOLAR HOUSE

THE SET OF CEN STANDARDS DEVELOPED TO SUPPORT THE IMPLEMENTATION OF THE ENERGY PERFORMANCE OF BUILDINGS DIRECTIVE (EPBD) IN THE EU MEMBER STATES

Achieving Energy Savings in Europe through the Energy Performance of Building Directive (EPBD)

Energy Performance of Buildings Directive and nearly-zero Energy Buildings

Energy efficiency of buildings from Europe to Slovakia

REHVA Guidebook 22 Launch event 15 March 2017 ISH, Frankfurt, Germany

NEBB-ASHRAE elearning Course Descriptions for Technical Training E-Learning Courses

Standards & Specifications

European Energy Policy and Standardization Buildings and Building Components

Evaluating performance indices of a shopping centre and implementing HVAC control principles to minimize energy usage

Energy Performance of Buildings Directive: Achieving both high indoor air quality and low energy consumption in European buildings

intelligent Building Energy Management System (ibems) Stefano Mangili Schneider Electric Spa 25/05/2016

ABSTRACT: VENTILATION The European Commission, Energy Performance of Buildings Directive, and its Ventilation Implications. Eric Curd.

Desigo Total Room Automation. The unique solution for efficient and flexible rooms.

eu.bac System Certification Scheme Certifying Energy Efficiency of Building Automation and Control Systems, at first delivery and during the lifetime

Energy-efficient Building Control. close to you

Ventilation in residential buildings: A comparison of different calculation methodologies in the context of the EPBD

Calculation of the yearly energy performance of heating systems based on the European Building Directive and related CEN Standards

Integrated Room Automation and Energy Efficiency

Role of daylight in the existent and future French building regulations

Heat Pumps. and energy labelling regulations

Does NZEB pose a conflict to Good Indoor Air Quality? REHVA summit November 2017

Smart Home and Intelligent Building Control Energy Effi ciency in Buildings with ABB i-bus KNX

Variable Speed Solutions Outstanding Performance For Heat Pump Applications

Buildings and Energy a systematic approach

05/14/2012 THE CRIME OF IMPROPER ENERGY MANAGEMENT AGENDA

Energy Performance of Buildings Status and Strategy for using Dynamical Calculation Methods

ENERGY-EFFICIENCY IN AIR-CONDITIONED BUILDINGS: AN OVERVIEW

Dynamic simulation of buildings: Problems and solutions Università degli Studi di Trento

Jean Daniel (Dan) Napar President eu.bac

Air distribution and temperature control in classrooms

A smart EPBD for people, business and the environment. Stephan Kolb eu.bac/danfoss

PROJECT DOCUMENT. Status: PUBLIC

Complying with the Minimum Energy Efficiency Standards (MEES)

P155. cense. [European projects] Johann Zirngibl Jean Christophe Visier Centre Scientifique et Technique du Bâtiment, CSTB, France

DIRECTIVE 15H-9 Issue date: October 2018 COMMISSIONING

Indoor environment for energy performance of buildings a new European draft standard

Energy efficiency in the Industry Istanbul Torsten Szypulski. Controlesta RCO

VENTILATION 2006, Chicago, May.

Halton Chilled beams Janne Summanen Halton Oy

KNX The worldwide STANDARD for home and building control. KNX Association International

AM-55, AM-56) B U I L D I N G P A R T N E R S H I P S F O R E N E R G Y S E C U R I T Y

FLEXY EC HIGH EFFICIENCY ROOFTOP kw AIR COOLED COOLING ONLY/HEAT PUMP/ GAS/ DUAL FUEL

ENERGY CONSERVATION IN BUILDINGS AND COMMUNITY SYSTEMS. Technical Report. P. Michel & M. El Mankibi ENTPE DGCB LASH France

The European Approach to Decrease Energy Use in Buildings Towards ZEB (Zero Energy Buildings)

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

CLIMACIAT TAILOR-MADE INDOOR AIR QUALITY CLIMACIAT CLIMACIAT CLIMACIAT. airclean. airtech. airaccess AIR HANDLING UNIT NA16.14A

eu.bac Position Paper

NZEB: The new challenge of HVAC Manufacturers. ASTRO Tower (Archi Urbain)

EPA-NR Software In line with the EPBD and the CEN-standards

Roof top. NEW SPACE Zen attitude NA O8.16B

Georgetown University New Science Center

ROOF TOP SPACE. SELF-CONTAINED REVERSIBLE AIR-AIR UNITS OF 23 TO 281 kw EVERY EFFICIENT SOLUTION FOR UNIVERSAL COMFORT NA C

Optimization of Building Energy Management Systems

2nd recast of the EPBD Energy, IEQ, smart buildings & digitalisation

The energy benefits of View Dynamic Glass

ISO INTERNATIONAL STANDARD. Energy performance of buildings Calculation of energy use for space heating and cooling

Integrated Design. Architectural Design v/s HVAC Design. HVAC Design after Architectural design

NEBBinar: Retro-Commissioning for Comfort and Energy Efficiency. August 21, 2013

Audits and inspections in HVAC Auditorias e inspecções aos sistemas de AVAC

BCM00 Introduction to Building Controls and HVAC (available on request) One day course BCIA Members VAT Non-members VAT

Smart Buildings A eficiência energética em edifícios é a resposta. Qual é a pergunta?

HunterDouglas Powerful, Versatile Control Solutions

THE PROGRAMS AND RESOURCES OF FACULTY OF MECHANICAL ENGINEERING

Xavier Energy Initiative

P60. More information on the set of CEN standards for the EPBD. [Information on Standardisation] > Introduction

Calculation Methods What we can use in existing EN and ISO standards. Need for further development

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

Building Energy and Location JRC Energy & Cities project; from building to urban area

UTILIZE THE BENEFITS OF DAYLIGHT, SOLAR GAINS, SOLAR PROTECTION, NATURAL VENTILATION AND EVEN MORE

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

Acutherm was spec d here. Building Automation Guide for Therma-Fuser Systems

Energy Efficient Cities. Oddgeir Gudmundsson, Director, Projects. One Company. Focused on Climate & Energy. 1 Danfoss Heating Segment A&T Projects

Computational and the real energy performance of a single-family residential building in Poland an attempt to compare: a case study

Reducing Hospital Energy Use and Maintaining Savings. Glen Anderson, PE

Retro-commissioning and on-going commissioning 23 November 2016

AIT Austrian Institute of Technology

Atrium. heating panel. the future of space conditioning

Built examples and project certification. Zeno Bastian, Passive House Institute

ENERGY MODELING GUIDELINES. D. Section Building Automation and Control System Guidelines

Energy modeling in IDA ICE according to ASHRAE , app. G

How to Design Zero Emission Buildings

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Non-Residential Passive House Buildings

Towards Sustainable and Intelligent Built Environment

Technical Report Three Mechanical Systems Existing Conditions Evaluation

2014 ENERGY REPORT. Mark J. Ferguson, P.E. Campus Operations & Plant Manager

Room automation for laboratories. Safety and a pleasant climate for life sciences and the healthcare sector.

Efficient and smart climate shell. refurbishment of residential buildings PART OF SMART SOLUTION 1: EFFICIENT AND SMART CLIMATE SHELL REFURBISHMENT

Influence of Building Automation and Control Systems (BACS) on Energy Standards and Energy Efficiency

BUILDING DESIGN FOR HOT AND HUMID CLIMATES IMPLICATIONS ON THERMAL COMFORT AND ENERGY EFFICIENCY. Dr Mirek Piechowski 1, Adrian Rowe 1

BULGARIAN LEGISLATION IN THE FIELD OF ENERGY EFFICIENCY HEAT RETENTION AND ENERGY CERTIFICATION OF NEW AND EXISTING BUILDINGS

Attaining Thermal Comfort in. Buildings with Predominantly. Glazed Facades. presented to: ANSYS Boston Regional Conference

HEATING WITHOUT GLOBAL WARMING? FREQUENTLY ASKED QUESTIONS ABOUT DISTRICT HEATING AND DISTRICT COOLING

ENERGY CONSERVATION STRATEGIES FOR HVAC SYSTEMS

Transcription:

The impact of Building Automation on Energy Efficiency Siemens with DESIGO and Synco best in class Page 1 Siemens AG, plc, 2010 2009 All Rights Reserved

Energy is a major issue for the European Union Primary energy use in Europe Transport 28% Buildings 41% Industry 31% Impact of Building Automation Efficiency improvement and modernisation can save up to 30 percent Dependency Without provisions, dependency on external energy will rise to 70% Environment Energy production and consumption create 94% of CO 2 emissions Supply Influence on energy supply is limited Cost Substantial increase within a few years Page 2

Legislation, standardization & certification The EU mandated European CEN to standardise calculation methods for improving energy savings EPBD CEN TC247 prepared and approved EN15232 impact of BACS functions on energy efficiency Product standards with energy performance criteria (e.g. EN15500) eu.bac prepared the certification procedure and test method and proposed this certification to the European Community CEN: EN: Page 3 European Committee for Standardization European Norm

EU and national legislation European Parliament and the Council on the Energy Performance of Buildings European Union Directive for Energy Performance of Buildings EPBD RT2005 All EU-Members: Laws and Administrative regulations Calculation methods Energy certification of buildings Part L of the Building Regulations and implementing the Energy Performance of Buildings Directive Energieeinsparverordnung EnEV Starting 2006 Page 4

EPBD Definition of Energy Performance of Buildings Energy performance of a building means the amount of energy actually consumed or estimated to meet the different needs associated with a standardised use of the building, which may include: Heating Hot water heating Cooling Ventilation Lighting Auxiliary energy Therm. Energy El. Energy Page 5

Standardisation related to energy efficiency EU mandate for CEN to standardise calculation methods for energy efficiency improvement EN 15232 "Energy performance of buildings Impact of Building Automation" And Product standards (e.g. EN 15500, EN 12098) Terminology Product data's and Energy performance criteria Test procedure Page 6

EU norms for Building Automation Product System Building EN 15500 Electronic individual zone control equipment EN 12098 Control equipment for hot water heating systems Products are certified by eu.bac ISO EN 16484 Building automation and control systems, incl. BACnet protocol ISO/IEC DIS 14908 LonTalk protocol EN13321, EN50090 KNX protocol EN 15232 Impact Building Automation on energy efficiency European Directive 2002/91/EC Main legislative instrument to achieve energy performance in buildings Page 7

BACS * are the brain of the building BACS monitor, optimise, interlock and control Heating systems, Air conditioning systems, Cooling systems, Lighting systems and blinds, Fire and security systems, Lifts, etc. In fact BACS integrate the most important information of technical equipment in the building and act as a central point or "Brain" of the building BACS functions influence The calculation of planned energy efficiency The real use of energy * BACS: Building Automation and Controls System Page 8

Calculation procedures based on BAC efficiency factors EN 15232 BACS Energy Performance Classes A B C D Class A: High energy performance BACS and TBM Class B: Advanced BACs and TBM Class C: Standard BACS (is normally used as reference) Class D: Non energy efficient BACS BACS Building Automation and Controls System TBM Technical Building Management Systems Page 9

Energy efficiency under EN 15232: Targeting integrated room automation Demand control workspace with machinery Conference room Office Controlling energy supply based on room demand to achieve the ultimate energy efficiency! Page 10

Function list and assignment to energy performance classes EN 15232 Definition of classes Residential Non residential D C B A D C B A Automatic control Heating control Emission control The control system is installed at the emitter or room level, for case 1 one system can control several rooms 0 No automatic control 1 Central automatic control 2 Individual room automatic control by thermostatic valves or electronic controller 3 Individual room control with communication between controllers and to BACS 4 Integrated individual room control including demand control (by occupancy, air quality, etc.) Control of distribution network hot water temperature (supply or return) Similar function can be applied to the control of direct electric heating networks 0 No automatic control 1 Outside temperature compensated control 2 Indoor temperature control Unless differently specified by public authorities the minimum level of functions to be implemented corresponds to class C. Public authorities wishing to modify the minimum requirements shall adapt this table. Page 11

BACS efficiency factors determined for different user profiles Lecture hall Hotel Restaurant Hospital Office School Wholesale centre User profiles as defined by EN 15232 Page 12

BACS efficiency factors EN 15232 Thermal energy Electrical energy Class D C B A D C B A Offices 1,51 1 0,80 0,70 1,10 1 0,93 0,87 Lecture hall 1,24 1 0,75 0,50 1,06 1 0,94 0,89 Education 1,20 1 0,88 0,80 1,07 1 0,93 0,86 Hospitals 1,31 1 0,91 0,86 1,05 1 0,98 0,96 Hotels 1,31 1 0,85 0,68 1,07 1 0,95 0,90 Restaurants 1,23 1 0,77 0,68 1,04 1 0,96 0,92 Wholesale & retail 1,56 1 0,73 0,60 1,08 1 0,95 0,91 Residential 1,10 1 0,88 0,81 1,08 1 0,93 0,92 Page 13

Example: Ventilation plant restaurant Schematic diagram Page 14

Example: Ventilation plant restaurant Demand control Air quality sensor Page 15

Example: Ventilation plant restaurant Page 16 Class C Class A

Example: Ventilation plant restaurant Air flow control Variable speed drive instead of fan 2-stage Page 17

Example: Ventilation plant restaurant Class C Class A Page 18

eu.bac Certification for BACS EU Mandate for CEN to standardization of Calculation methods for energy efficiency improvement TC247: EN 15232 "Energy performance of buildings Impact of Building Automation" and Product Standards Terminology Product data's incl. energy performance criterias Test procedure Rules Test Tool Independent Certifier Accredited laboratory Page 19

Why eu.bac? The European BACS industry joined forces and competences to propose practical solutions: For the reduction of greenhouse gas emissions in buildings For a European Quality Assurance system for energy efficient building automation and controls equipment For the introduction of a legal framework for energy savings performance contracting in buildings Based on eu.bac Cert equipment and systems Initiated by Siemens and first presidency Page 20

eu.bac Cert Implementation plan First certified products in September 2007 Individual zone controllers Stepwise release of various applications (e.g. hot water radiator heating, chilled ceiling, VAV etc.) Further products under preparation by eu.bac Heating controllers incl. optimiser Field components (temperature sensors, valves and actuators, etc.) Building Automation Systems Page 21

Impact on energy savings of high quality room controllers Energy savings France 15% New office > 1000m 2 Energy savings (%) 10% 5% e.g. 3..14% energy savings by H2 H1 0% 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 CA = max (CV, CSD) (K) Natural gaz heating H1 Natural gaz heating H3 Electric heating H2 Natural gaz heating H2 Electric heating H1 Electric heating H3 H3 Temperature control accuracy compliancy CA: Eu.bac: 1.4K (radiator heating) EN15500: 2.0K Source: CSTB France Page 22

Siemens Building Technologies Achieves EN 15232 efficiency class A and eu.bac Cert with high performance Delivers even higher system functionality than required under energy performance class A (EN15232) Page 23

Siemens grants for EN 15232 efficiency class A and eu.bac Cert with high performance Management level Energy efficiency functions: Energy consumption report Alarm and status reports Trend reports Easy-to-use time schedulers, set points, etc. Automation level Field level Synco living Demand control with CO 2 or presence sensors Lighting and blinds control Variable speed pump and fan control Synco700 DESIGO Generation control with variable temperature dependent on outdoor temperature or load Sequencing of diff. generators based on various inputs Interlock heating / cooling Optimum start / stop H,x directed control Individual room control with central operation and data link to primary heating or cooling plant Page 24

Test results for Siemens room controllers Example: Fancoil with motoric actuator Energy savings DESIGO TM RX 15% New office > 1000m 2 Energy savings (%) 10% 5% CC 0% DESIGO 0.0 RXC21 Fan-Coil H 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 CA = max (CV, CSD) (K) Natural gaz heating H1 Natural gaz heating H2 Temperature control accuracy compliancy CA: Eu.bac: 1.4K EN15500: 2.0K Source: CSTB France Page 25 Natural gaz heating H3 Electric heating H1 e.g. 3..14% energy savings by Electric heating H2 Electric heating H3 Best in class

eu.bac Certification Amortisation time & cost savings Amortization time Positioning of actuators Motoric valves CA = 0.1K Motoric valve actuator (24 VAC / 0..10V) Cost savings for motoric valves Therm. valves 0-10V CA = 0.7K 10% energy savings 1) Investment 7% energy savings 1) 5% energy savings 1) Price Thermic valve actuator (0..10V) Therm. valves 24V CA = 1.0K Amortisation time for mot. vs. therm. valves Time Thermic valve actuator (24VAC) Cost amortisation time 0.1 0.2 0.6 0.8 1.0 1.2 Control accuracy 1) Compare to EN 15500 for natural gaz heating in South France Page 26

DESIGO V4 Predictive and adaptive heating controller Solution: Outside temperature prediction (integrated) Model-based optimisation of supply water temp. Start / stop optimisation Adaptation of model parameters, incl. adaptive heating curve Optimization of supply water temp. set point for min. energy consumption without sacrificing comfort Parameters Prediction Predictive, model-based and adaptive heating controller t t commands Benutzerbefehle Outside Aussentemperatur Temperature - Profile profil Room Temperature Profile Raumtemperatur - Sollwertprofil Room temp. profile t t Geregeltes Controlled system System Flow temperature Vorlauftemperatur setpoint profile Sollwert Outside Temp. Solar Temp. Gains Internal Temp. Gains Wind Flow temperature Vorlauftemperatur - controller Regler T T Outside Temp. T Raum Room Raum Room Room Temp. Benefits: Comprehensive control concept Comprehensive functionality with few settings One (fully adaptive) function to replace conventional solution consisting of separate functions (Heating curve, heating release algorithm, optimum start stop control) Proven standard solution Operation and monitoring on DESIGO Insight: Page 27

A new Siemens brochure: Supports the Building Automation planning phase CM110854 Target groups: All persons involved in planning phase of buildings and specifically Building Automation Target and benefits: To become familiar with EN 15232 "Energy performance of buildings" "Impact of Building Automation, Controls and Building Management" To become familiar with the benefits of product certification by eu.bac (European Building Automation Controls Association) To be able to select the BAC functions according to their impact on energy efficiency of buildings Page 28

Siemens EPC Tool - supports classification of Building Automation and Controls Systems Page 29

Conclusions Impact of building automation on energy efficiency Page 30

Typical categorization of energy saving potentials in buildings Category Measures, e.g. Saving potential [%] Amortisation [years] Building automation Technical installations Building envelope Installation and optimised tuning of energy functions Optimisation during operation by efficient use of BACS and weak point analysis dynamic energy management HVAC, refrigeration, lighting Controls, motors, actuators, Power generation Insulation, windows Thermal bridges, construction physics 5-30 0-5 10-60 2-10 >50 10-60 Conclusion: Page 31 Invest first in building automation and control! Results in highest ROI quickly

Building automation and building management life cycle Adapt the operational parameters Decide on additional automation Monitor and analyze the building operation and technical installations Specify and install energy functions with BACS (EN15232) and devices with. Definition of classes Residential Non residential D C B A D C B A Automatic control Heating control Emission control The control system is installed at the emitter or room level, for case 1 one system can control several rooms 0 No automatic control 1 Central automatic control 2 Individual room automatic control by thermostatic valves or electronic controller 3 Individual room control with communication between controllers and to BACS Integrated individual room control including demand control 4 (by occupancy, air quality, etc.) Control of distribution network hot water temperature (supply or return) Similar function can be applied to the control of direct electric heating networks 0 No automatic control 1 Outside temperature compensated control 2 Indoor temperature control Page 32

Conclusions about optimizing building operation Even with building automation, you still need To identify optimisation potential To know the synergies between the building, the technical installations, the environment and the user To master guidelines, directives and laws A willingness to constantly face new challenges! The brain is still sitting in front of the monitor!! Page 33

Summary: Legislation Standardization Certification Legislation Standardisation EU Directive EN 15500 EN 15232 National decrees Certification Product Standards with quality and energy performance criteria Energy Performance of Buildings Impact of Building Automation Europe wide product certification ISO16484-x EN14908-x EN50090-x BACS functions Communication protocols Building Automation industry can highlight the value of BACS Page 34

The value of BACS = Saving potentials by intelligent use of Building Automation (EN 15232) Hotels Education Hospitals Residential Th.32% El.10% Th.20% El.14% Th.14% El.4% Restaurants Shopping C. Offices Th.19% El.8% Th.32% El.8% Th.40% El.9% Th.30% El.13% Determined by means of building simulation / FH Aachen DE Page 35

Siemens reference project: City of Boras, Sweden school campus Erikslund Measures taken: Control parameters and set point values optimized, time programs adjusted Demand controlled energy production; The district heat connection was turned off during the summer months non-functioning dampers replaced, that were letting in too much fresh air School for 1 100 students with heated area of 12 600 m2 Result: Energy reduction for Heating (DGD adjusted): 707 000 kwh 32% Electric: 100 000 kwh 14% CO2: - 824t Amortisation < 1 year Page 36

Siemens reference project: Hospital in Belgium - Algemeen Stedelijk Ziekenhuis Aalst Measures taken : Set point values and time programs adjusted Optimized control of the heat exchangers, pumps and valves Implementation of an OSTP algorithm Improved control strategy for cooling generation and distribution Polyclinic: 5 000 m2 Amortisation 6 months Page 37 Result: Energy reduction for Heating (DGD adjusted): 341 098 kwh 35.7% Electric: 295 376 kwh 15.8% CO2: - 22%

Ian Ellis Marketing Manager Control Products & Systems President Building Controls Industry Association Sir William Siemens Square, Frimley, GU16 8QD Tel: +44 1276 690755: Fax: +44 870 850 8473 Mobile:+44 7808 827978 E-Mail: ian.ellis@siemens.com Page 38