MAINTENANCE MEZZANINE PROJECT NO CONTRACT NO

Similar documents
1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Preassembled steel stairs with concrete-filled treads.

B. Shop Drawings: Include plans, elevations, sections, details, and attachments.

B. Shop Drawings: Include plans, elevations, sections, details, and attachments to other work.

PIPE AND TUBE RAILINGS. Evansville Christian High School RELATED DOCUMENTS 1.1

SECTION METAL FLOOR PLATE STAIRS

Student Services & Classroom Addition

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB ADPH #B

SECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.

SECTION Temperature Change: 120 deg F, ambient; 180 deg F, material surfaces.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

STRUCTURAL STEEL FRAMING

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

METALS Commissioning of Metals Structural Steel Framing Steel Studs... 2

Multi-Institutional Academic Health Science & Research Center Evansville, IN

STRUCTURAL STEEL FRAMING Section

SECTION PIPE AND TUBE RAILINGS

Commission No Section

C. Miscellaneous Metal Fabricators are specified elsewhere in Division 5.

SECTION 2 DIVISION 05 METALS

SECTION AWNINGS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

1. Seismic Loads: Reference structural drawings.

Student Services & Classroom Addition

SECTION METAL STAIRS

B. Products furnished, but not installed, under this Section include the following:

SECTION STRUCTURAL STEEL

SECTION STRUCTURAL METAL FRAMING

. SECTION HANGERS AND SUPPORTS

SECTION MISCELLANEOUS METALS

Lapeyre Stair, Inc. (800)

1. Manufacturer's product lines of railings assembled from standard components.

A. Structural Steel: Elements of structural-steel frame, as classified by AISC 303, "Code of Standard Practice for Steel Buildings and Bridges.

SUNY GENESEO RED JACKET DINING HALL RENOVATION SECTION STRUCTURAL STEEL FRAMING

East Central College

Construction Standards PAGE

DIVISION 5 METALS SECTION STRUCTURAL STEEL

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

SECTION METAL DECKING. A. Extent of metal decking is indicated on Plans, including basic layout for the following type of deck required:

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

PIPE AND TUBE RAILINGS

SECTION STRUCTURAL STEEL

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION METAL FABRICATIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION METAL FABRICATIONS PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY 1.3 PERFORMANCE REQUIREMENTS

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

PIPE AND TUBE RAILINGS

A. Access doors and frames are part of an access door and frame allowance.

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

1. Include plans, elevations, sections, details, and attachments to other work.

SECTION METAL WALL PANEL SYSTEM

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III

PART 1 GENERAL METAL RAILINGS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION STRUCTURAL STEEL

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Trex Commercial Products page Metal Railing

Section PANEL SIGNAGE

Products furnished, but not installed, under this Section include the following:

DECORATIVE METAL RAILINGS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Facility Repairs - MCAS Cherry Point - Tank Farm A SECTION STRUCTURAL STEEL 05/14

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION STEEL H PILES. A. Section includes steel H piles embedded into drilled concrete piers.

SECTION STRUCTURAL STEEL

SECTION STRUCTURAL STEEL FRAMING

SECTION METAL STAIRS

SECTION DECORATIVE METAL AND GLASS RAILING

Daytona Beach Pier Building Renovation Jun 2010

a. Uniform load of 50 lbf/ ft. applied horizontally and concurrently with 100 lbf/ ft. applied vertically downward.

SECTION FOOD DISPENSING EQUIPMENT- SNEEZE GUARDS AND PARTITION POSTS

1. ADA-ABA Accessibility Guidelines and ICC/ANSI A ASTM International (formally American Standards for Testing & Materials)

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

STANDARD SPECIFICATION FOR ALUMINUM FRAMING FOR RAILROAD PASSENGER SHELTERS

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS CONSTRUCTION PACKAGE

SECTION ALUMINUM RAILINGS

SECTION MISCELLANEOUS METAL. A. The Contractor shall furnish and install the miscellaneous metal as shown on the plans and as specified herein.

SECTION ALUMINUM HANDRAIL SYSTEMS

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

Northpointe Renovation EPN #1701 F/A Prroject #17027 September 8, 2017

A. American Society for Testing and Materials (ASTM):

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION HIGH-PERFORMANCE COATINGS

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

SECTION (05300) - STEEL DECKING

SECTION ORNAMENTAL WELDED STEEL FENCING

Section 716. SHOP CLEANING AND COATING STRUCTURAL STEEL

DIVISION 5 METALS SECTION METAL DECKING

1. Include construction details, materials, individual components and profiles, and finishes.

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SPECIFICATIONS: Architectural Aluminum Railings

Tnemec 394 Proprietary Long Form Coatings Schedule

Transcription:

PORT OF TACOMA FILE: D:\OneDrive\Vector\Clients\04-Cardno\Maintenance Mezzanine\CAD\Sheet Files\MID 040.0 COVER_MEZZ PROJECT NO. 040.0 CONTRACT NO. 070735 PORT COMMISSIONERS: CONSTANCE T. BACON DON MEYER DONALD C. JOHNSON RICHARD P. MARZANO CLARE PETRICH PROJECT LOCATION SHEET DESIGNATION DRAWING LIST SHEET # SHEET TITLE REVISION G. COVER SHEET A. 2 MAIN FLOOR PLAN A.2 3 MEZZANINE FLOOR PLAN A.3 4 MEZZANINE ELEVATION S0.0 5 STRUCTURAL SPECIAL INSPECTION NOTES PORT STAFF: S.0 6 MEZZANINE FOUNDATION PLAN S.02 7 MEZZANINE FRAMING PLAN JOHN WOLFE Chief Executive Officer DAKOTA CHAMBERLAIN Director of Facilities Development M.0 8 MECHANICAL LEGEND, DETAILS, AND NOTES M. 9 MECHANICAL DEMOLITION PLANS M.2 0 MECHANICAL FLOOR PLANS FX. FIRE PROTECTION MAIN FLOOR PLAN E. 2 ELECTRICAL DEMOLITION PLAN E2. 3 LIGHTING FLOOR PLAN E3. 4 POWER AND FIRE ALARM FLOOR PLAN JANE VANDENBERG, PE Director of Engineering STANLEY RYTER, PE Project Manager CONSULTANTS: SEATTLE 80 SECOND AVENUE, STE 700, SEATTLE, WA 9904 TEL: (206) 269-004 www.cardno.com 225 North 30th Street, SPECIAL INSPECTION G. SH OF 4 COVER SHEET P.O. BOX 837 TACOMA, WA 9840 (253)383-584

PORT OF TACOMA FILE: D:\OneDrive\Vector\Clients\04-Cardno\Maintenance Mezzanine\CAD\Sheet Files\MID 040.0 A.-A.3_MEZZ A. SH 2 OF 4 MAIN FLOOR PLAN P.O. BOX 837 TACOMA, WA 9840 (253)383-584 BLDG. DEPT. REVISIONSGM 0/24/208

PORT OF TACOMA FILE: D:\OneDrive\Vector\Clients\04-Cardno\Maintenance Mezzanine\CAD\Sheet Files\MID 040.0 A.-A.3_MEZZ A.2 SH 3 OF 4 MEZZANINE FLOOR PLAN P.O. BOX 837 TACOMA, WA 9840 (253)383-584 BLDG. DEPT. REVISIONSGM 0/24/208

ADDENDUM No 260768.20 JFS /6/208 P.O. BOX 837 TACOMA, WA 9840 (253)383-584 STRUCTURAL SPECIAL INSPECTION NOTES MEZZANINE FOUNDATION PLAN 225 North 30th Street, 5B. REQUIRED VERIFICATION AND INSPECTION OF STRUCTURAL STEEL CONSTRUCTION INSPECTION OF BOLTING 00% Submittal SH 57 OF 5 8 A S0.0. D 3. REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION PORT OF TACOMA FILE: C:\Users\dramsay\appdata\local\temp\AcPublish_7064\260768_S.00. STATEMENT OF SPECIAL INSPECTION 5A. REQUIRED VERIFICATION AND INSPECTION OF STRUCTURAL STEEL CONSTRUCTION INSPECTION OF WELDING

PORT OF TACOMA FILE: Q:\206\260768\20_STR\CAD\260768_S.00 MEZZANINE FOUNDATION PLAN 3/6" = '-0" PRE-ENGINEERED STEEL MEZZANINE CLUMNS SURFACE MOUNTED ON EXISTING 8 INCH THICK CONCRETE SLAB ON GRADE SECTION 055000 PRE-ENGINEERED STEEL MEZZANINE PART - GENERAL. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification Sections, apply to this Section..2 SUMMARY A. Products furnished under this Section include the following: Pre-engineered steel mezzanine.3 COORDINATION A. Coordinate installation of the mezzanine structure with other work..4 ACTION SUBMITTALS A. Shop Drawings: Show fabrication and installation details. Include plans, elevations, sections, and details of the mezzanine framing and their connections including connections to the existing building slab..5 INFORMATIONAL SUBMITTALS A. Mill Certificates: Signed by steel manufacturers, certifying that products furnished comply with requirements. B. Welding certificates..6 QUALITY ASSURANCE A. Welding Qualifications: Qualify procedures and personnel according to AWS D./D.M, "Structural Welding Code - Steel." B. Welding Qualifications: Qualify procedures and personnel according to the following:. AWS D./D.M, "Structural Welding Code - Steel.".7 FIELD CONDITIONS A. Field Measurements: Verify actual locations of construction contiguous with metal fabrications by field measurements before fabrication. PART 2 - PERFORMANCE REQUIREMENTS 2. ALL METHODS, MATERIAL, AND WORKMANSHIP SHALL CONFORM TO THE 205 INTERNATIONAL BUILDING CODE (IBC) AS AMENDED AND ADOPTED BY THE LOCAL BUILDING AUTHORITY. A. DESIGN CRITERIA. DESIGN THE MEZZANINE FLOOR FOR MINIMUM 250 PSF LIVE LOAD 2. DESIGN GUARDRAILS, HANDRAILS, AND GRAB BARS FOR 50 PLF UNIFORM LOAD AND 200LB CONCENTRATED LOAD EACH ACTING INDEPENDENTLY. 3. DESIGN THE MEZZANINE FOR SEISMIC LOADING INCLUDING SEISMIC LOADS PER IBC SECTION 63 AND ASCE 7 CHAPTERS THRU 3 WITH THE FOLLOWING FACTORS: RISK CATEGORY:II SEISMIC IMPORTANCE FACTOR:.0 Ss:.296 S:0.503 SITE CLASS: D Sds: 0.864 Sd:0.503 SEISMIC DESIGN CATEGORY: D 2.2 METALS A. Metal Surfaces, General: Provide materials with smooth, flat surfaces unless otherwise indicated. For metal fabrications exposed to view in the completed Work, provide materials without seam marks, roller marks, rolled trade names, or blemishes. B. Steel Plates, Shapes, and Bars: ASTM A 36/A 36M. C. Rolled-Steel WT Sections: ASTM A 992 Fy=50 ksi 2.3 FABRICATION, GENERAL A. Shop Assembly: Preassemble items in the shop to greatest extent possible. Disassemble units only as necessary for shipping and handling limitations. Use connections that maintain structural value of joined pieces. Clearly mark units for reassembly and coordinated installation. B. Cut, drill, and punch metals cleanly and accurately. Remove burrs and ease edges to a radius of approximately /32 inch unless otherwise indicated. Remove sharp or rough areas on exposed surfaces. C. Form exposed work with accurate angles and surfaces and straight edges. D. Weld corners and seams continuously to comply with the following:. Use materials and methods that minimize distortion and develop the strength of base metals. 2. Obtain fusion without undercut or overlap. 3. Remove welding flux immediately. 4. At exposed connections, finish exposed welds and surfaces smooth and blended so no roughness shows after finishing. 2.4 STEEL COMPONENTS A. General: Provide steel components as needed to complete the Work. B. Fabricate units from steel shapes, plates, and bars unless otherwise indicated. Fabricate to sizes, shapes, and profiles indicated and as necessary for close and accurate fit-up with adjacent construction. 2.5 FINISHES, GENERAL A. Finish metal fabrications and adjacent metal surfaces after installation. B. Field prime steel components after installation using Universal Primer: Fast-curing, lead- and chromate-free, universal modified-alkyd primer complying with MPI#79 and compatible with topcoat.. Use primer containing pigments that make it easily distinguishable from zinc-rich primer. C. Preparation for Field Priming: Prepare unpainted/ unprimed surfaces to comply with SSPC- SP 3, "Power Tool Cleaning.". Clean existing adjacent steel surfaces abraded, discolored, or otherwise affected by the work performed under this contract/work order D. Field Priming: Apply primer to comply with SSPC-PA, "Paint Application Specification No. : Shop, Field, and Maintenance Painting of Steel," on all unpainted surfaces of new steel components and to existing adjacent steel surfaces abraded, discolored, or otherwise affected by the work under this contract/work order.. Stripe paint corners, crevices, welds, and sharp edges. E. Field paint all primed steel with paint that matches color and finish of steel framing adjacent to and unaffected by the work completed under this contract/work order. Verify that the type, manufacturer, color, and finish of the paint is acceptable to the Owner by submitting color and texture samples to the Owner for acceptance before acquiring the paint. The paint shall be compatible with the primer used. 2.6 ADJUSTING AND CLEANING A. Touchup Painting: clean abraded areas. Paint uncoated and abraded areas with the same material used for field priming to comply with SSPC-PA for touching up field-painted surfaces.. Apply by brush or spray to provide a minimum 2.0-mil dry film thickness. B. Touchup Painting: Clean and touchup paint field welds and abraded areas of painted surfaces. C. END OF SECTION 055000 225 North 30th Street, MAINTENANCE MEZZANIN P.O. BOX 837 TACOMA, WA 9840 (253)383-584 MEZZANINE FOUNDATION PLAN OF 8 260768.20 S.0 5 SH 6 7 ADDENDUM No JFS /6/208 00% Submittal

PORT OF TACOMA FILE: Q:\206\260768\20_STR\CAD\260768_S.00 PROVIDE CLEARANCE FOR SLIDING DOOR BAR GRATING BY PE MEZZANINE MFR. TOP OF GRATING 0'-0" AFF MEZZANINE MFR TO PROVIDE PLATE TO SPAN GAP BETWEEN NEW AND EXISTING STRUCTURES AT ALL WALKWAYS BETWEEN THEM WHILE AT THE SAME TIME ALLOWING FREEDOM OF RELTIVE MOVEMENT BETWEEN NEW AND EXISTING. PRE-ENGINEERED STEEL MEZZANINE MEZZANINE FRAMING PLAN 3/6" = '-0" PROVIDE CLEARANCE BETWEEN EDGE OF MEZZANINE AND EXISTING STRUCTURE TO ACCOMODATE MOVEMENT ASSOCIATED WITH SEISMIC LOADING MEZZANINE MFR TO PROVIDE PLATE TO SPAN GAP BETWEEN NEW AND EXISTING STRUCTURES AT ALL WALKWAYS BETWEEN THEM WHILE AT THE SAME TIME ALLOWING FREEDOM OF RELTIVE MOVEMENT BETWEEN NEW AND EXISTING S.02 5 SH 78 MAINTENANCE MEZZANIN MEZZANINE FRAMING PLAN OF 8 260768.20 225 North 30th Street, P.O. BOX 837 TACOMA, WA 9840 (253)383-584 00% Submittal ADDENDUM No JFS /6/208