HIGH-LEVEL DISINFECTANT RAPICIDE. Safety, Efficacy, and Microbiological Considerations

Similar documents
HIGH-LEVEL DISINFECTANT AND STERILANT

Safety, Efficacy, and Microbiological Considerations. * For use with RAPICIDE PA outside of the USA, Canada and Australia

High-Level Disinfectant and Sterilant. Rapicide SAFETY, EFFICACY AND MICROBIOLOGICAL CONSIDERATIONS

Rapicide High-Level Disinfectant and Sterilant. Safety, Efficacy, and Microbiological Considerations

Safety, Efficacy & Microbiological Consideration

Safety, Efficacy & Microbiological Consideration

ENVIROCIDE. Technical Bulletin

8,000 facilities count on it

Appendix 2. Revised 510(k) Summary

MAR COR RESEARCH REPORT. Fast, Safe, Reliable Surface Disinfection for the Life Sciences Market. Competent, Consistent, & Compliant

TOXICITY, EFFICACY, STABILITY AND CORROSION TEST RESULTS

Technical Data Monograph. Reliance EPS Endoscope Processing System

Infection Prevention in Endoscopy, Keeping Patients and Practioners Safe

Virusolve + EDS. Concentrated Sporicidal High Level Disinfecting Fluid for Endoscopes & Medical Instruments Technical Information

The New Choice in Disinfection Technology

Ready-To-Use Cleaning and Disinfecting Fluid for Endoscopes & Medical Instruments Technical Information

FREQUENTLY ASKED QUESTIONS FOR THE ADVANTAGE

Guidelines for Selection and Use of Disinfectants

Technical Data Monograph. V-PRO max Low Temperature Sterilization System

Glyphosate Technical

Validation Strategy for an Automated Endoscope Reprocessor

Safety Data Sheet SECTION 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING

Imidacloprid Technical

Administrative Policies and Procedures. Cross Reference: Date Issued: 2/14 Date Reviewed: 9/14 Date: Revised: 12/14 Attachment: None Page of 1 of 6

SAFETY DATA SHEET. Identification of the material and the supplier. Rapid cleaning and grime removal. Wiri Auckland

Log Reduction & UV Deceptive Advertising

Products made in Switzerland

SYNONYMS: DiPel 8L DiPel L Plus DiPel 3.5SL DiPel SL DiPel ES.CPI

Best Practices for High Level Disinfection Part I

SAFETY DATA SHEET. Avalanche. DISTRIBUTOR 24 HR. EMERGENCY TELEPHONE NUMBERS Simplex Products

Understanding ANSI/AAMI ST 91. Flexible and Semi-Rigid Endoscope Reprocessing in Healthcare Facilities

MATERIAL SAFETY DATA SHEET

SAFETY DATA SHEET. Infinity Foaming Non Alcohol Hand Sanitizer. MANUFACTURER 24 HR. EMERGENCY TELEPHONE NUMBERS MISCO Products Corporation

Endoscopy What s New Up There? Frank Myers, MA, CIC, FAPIC

Issue Date: 29-May-2015 Revision Date 24-May-2015 Version IDENTIFICATION BC.HS-1041 UN1759. Built Laundry Detergent

Causes serious eye irritation Specific organ toxicity repeated exposure, Oral (Category 3), Central Nervous System

SAFETY DATA SHEET. MANUFACTURER 24 HR. EMERGENCY TELEPHONE NUMBERS Nova Pressroom Products

MATERIAL SAFETY DATA SHEET. In Case of Emergency, Call Syngenta Crop Protection, Inc. Post Office Box Greensboro, NC 27419

Bayer Environmental Science

SAFETY DATA SHEET. Identification of the material and the supplier. Enviro Bathroom & Toilet Cleaner. Rapid cleaning and grime removal.

SAFETY DATA SHEET SECTION 1 IDENTIFICATION. ALBA-RUST Expert Rust Remover

MATERIAL SAFETY DATA SHEET

SECTION 2: COMPOSITION/INFORMATION ON INGREDIENTS

DECON-PHENE Sterile Pharmaceutical Clean Room Formula Germicidal Detergent with Organic Soil Tolerance

SAFETY DATA SHEET FIXER HARDENER 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION 2. HAZARDOUS IDENTIFICATION

SAFETY DATA SHEET. Infinity Foaming Antibacterial Hand Soap. MANUFACTURER 24 HR. EMERGENCY TELEPHONE NUMBERS MISCO Products Corporation

SAFETY DATA SHEET. SSS Power Play Neutral Floor Cleaner

Component 2-Propenoic acid, homopolymer, sodium salt

NOMIX ENVIRO MATERIAL SAFETY DATA SHEET HILITE Page 1 of 5

MATERIAL SAFETY DATA SHEET

Cleaning and disinfection of surfaces and instruments

ENDOSCOPE REPROCESSING AND INFECTION CONTROL FOR ENDOSCOPY

CAS No.: & (R,S)-2-[(2,6-dimethylphenyl)-methoxyacetylamino]-propionic acid methyl ester

Safety Data Sheet SECTION 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING

DRANO MAX GEL CLOG REMOVER

Safety Data Sheet InVade Bio Drain Release Date: 5/27/2015 Print Date: 5/28/2015 Version 1.0

GREASY MONKEY. Directions for use Spray directly onto the area which needs greasing. Wait for 30 minutes to allow curing Repeat when required.

INGREDIENT NAME: Inert Ingredients: identity withheld as Trade Secret CONCENTRATION: % CAS NUMBER: N/A OSHA-PEL 8HR TWA: N/L

LEGACYPRO ECO PRO HYPO WASH

MATERIAL SAFETY DATA SHEET

BromMax 7.1 CONCENTRATED LIQUID BROMINE BIOCIDE

Monitoring Flexible Endoscope Channels to Assure Cleaning

This SDS adheres to the standards and regulatory requirements of the United States and may not meet the regulatory requirements in other countries.

SAFETY DATA SHEET. Step and Shine

PART 1 THINK PURITY ALGAECIDE SOLUTION COMMERCIAL READ THE LABEL BEFORE USING FOR PONDS, DUGOUTS/LAGOONS AND POTABLE WATER TANKS

KLEENGROW Product of Canada Green House Sanitizer - Fungistat - Deodorizer - Kills Bacteria; Controls Mildew SOLUTION INDUSTRIAL

POLYMEDCO, INC. ANA Calibrators. Section 1 Identification

SAFETY DATA SHEET. SSS Navigator #54 Savanna Concentrated Neutral Floor Cleaner RTU

MATERIAL SAFETY DATA SHEET

Safety Data Sheet according GB

Safety Data Sheet Per GHS Standard Format

SECTION 1: PRODUCT IDENTIFICATION AND USE. with water and used for aerial application to control wildfire. Emergency Telephone Numbers: (24 Hours)

Slide 1. Slide 2. Slide 3

MATERIAL SAFETY DATA SHEET #NMS700 KNOCKDOWN. CLASS A FIRE FIGHTING FOAM Concentrate. Section 1. CHEMICAL PRODUCT/COMPANY IDENTIFICATION

SAFETY DATA SHEET according to regulation (EC) no 1907/2006 Caste off Version 2 (UK) Issue date 07/30/2008

SAFETY DATA SHEET. SSS Navigator #54 Savanna Neutral Floor Cleaner. DISTRIBUTOR 24 HR. EMERGENCY TELEPHONE NUMBERS Triple S

SERVIAN 75 WG Version 4 Revision Date Print Date

RTV SILICONE CONFORMAL COATING SECTION 1- CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

SAFETY DATA SHEET. Exclamation mark. H314: Causes severe skin burns and eye damage. H302: Harmful if swallowed. H401: Toxic to aquatic life.

INGREDIENT NAME: Inert/Other Ingredients Proprietary Information CONCENTRATION: 99.20% CAS NUMBER: N/A OSHA-PEL 8HR TWA: N/L

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

SAFETY DATA SHEET. Blue Lightning Neutral Cleaner. DISTRIBUTOR 24 HR. EMERGENCY TELEPHONE NUMBERS Parish Maintenance Supply

MATERIAL SAFETY DATA SHEEET Lloyds Laboratories Inc. CONCRETE CLEANER (Liquid) PART # 82104, 82120, 82145

MATERIAL SAFETY DATA SHEET Bellacide 355

SAFETY DATA SHEET POOL CARE MINERAL STAIN OUT

I. Product and Company Information. II. Hazard Identification. III. Composition / Information on Ingredients. IV. First Aid Measures

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

MSDS Number: VORTEX SEED TREATMENT FUNGICIDE MSDS Version 2.0

Material Safety Data Sheet

CHEMICAL & FERTILIZER, LLC Safety Data Sheet

SAFETY DATA SHEET 1. PRODUCT AND COMPANY IDENTIFICATION. Product name: MontBrite 1240 solution

MSDS Number: PONCHO 600 MSDS Version 2.1

Technical Data Monograph. V-PRO max 2 Low Temperature Sterilization System

This product is a semi-clear liquid with no discernable odor. Primary routes of entry are inhalation, eye contact and skin contact.

Safety Data Sheet DEPARTURE HERBICIDE

Page 1 of 6 AdcoEco Laundry Detergent US GHS SAFETY DATA SHEET

SAFETY DATA SHEET. Neutro Clean Plus. DISTRIBUTOR 24 HR. EMERGENCY TELEPHONE NUMBERS Kandel & Son, Inc.

Low Temperature Processing. An Update on Guidelines, Standards and Requirements

MATERIAL SAFETY DATA SHEET

Transcription:

HIGH-LEVEL DISINFECTANT RAPICIDE PA Safety, Efficacy, and Microbiological Considerations 1

50096-959 Rev D 2011, MEDIVATORS, A Minntech Corporation Business Group All rights reserved. This publication is protected by copyright. Copying, disclosure to others or the use of this publication is prohibited without the express written consent of Minntech Corporation. Minntech reserves the right to make changes in the specifications shown herein without notice or obligation. Contact your Medivators representative or Medivators customer service for more information. 2

Contents Contents Product Description... 4 Intended Use... 4 Safety... 5 Efficacy... 6 Materials Compatibility... 9 Toxicity... 11 Biocompatibility... 13 Compatibility with endoscopes (500 cycles)... 14 Packaging Configuration... 14 3

PRODUCT DESCRIPTION Rapicide PA Solutions A and B are combined to produce a single use-solution for High-Level-Disinfection (HLD) of endoscopes and related accessories with peracetic acid (PAA) as the active agent. The characteristics of the single use-solution are: Active Ingredient: Peracetic Acid PAA Concentration: 1000-1300 ppm Minimum Recommended Concentration (MRC): 850 ppm Reuse Period: Single use High-Level Disinfection Claim: 5 Minutes at 30 o C Dilution Required: 1:1 to 48 water Activation Required: No Corrosion Inhibitors: Yes Rapicide PA is a single use liquid chemical germicide solution with PAA in the concentration range of 1000-1300 ppm. Rapicide PA also contains corrosion inhibitors and water conditioning agents. INTENDED USE Rapicide PA is intended for high-level disinfection of semi-critical clean, heat-sensitive endoscopes and related accessories in Medivators Advantage Plus or DSD Edge automated endoscope reprocessors (AER). Rapicide PA is intended for single use at 30ºC. Rapicide PA High-Level Disinfectant Test Strips are used to verify that the disinfectant concentration remains above the minimum recommended concentration (MRC). Read and follow the directions for use and precautionary statements contained in the package insert before using. 4

SAFETY In handling Rapicide PA, the following precautions should be followed: Rapicide PA parts A & B are corrosive. Always wear proper eye protection, and protective, chemicallyresistant gloves when handling Rapicide PA. Avoid contact with eyes, skin and clothing. In case of contact with eyes or skin, flush with copious amounts of water for a minimum of 15 minutes. Seek immediate medical attention in case of eye contact. Avoid breathing fumes or vapors. Prepare and use Rapicide PA only in well ventilated areas. Harmful if swallowed. If swallowed, drink large amounts of water. Do not attempt to induce vomiting. Call a physician immediately. Do not store Rapicide PA near or with food. Refer to product insert and manufacturer s instructions for reprocessing of medical devices in AER units. STORAGE Store Rapicide PA at temperatures of 25 o C (77 o F) or lower. Protect from freezing. NEUTRALIZATION AND DISPOSAL Dispose of this product in accordance with all applicable Federal, State and Local regulations. If allowed by federal, state or local regulatory authority, flush spilled solution of Rapicide PA (Solutions A & B combined) to the drain using cold water. Run cold water for 15 minutes. Do not reuse the empty containers. Triple rinse the containers with water and dispose of in an incinerator or in accordance with local, state or federal requirements. For more information on spills and disposal refer to the Rapicide PA spill cleanup and disposal document. 5

EFFICACY High-Level Disinfection Summary Rapicide PA will high-level disinfect with an exposure time of 5 minutes at 30 o C (86 o F) at a concentration equal to or greater than the minimum recommended concentration (MRC) of 850 ppm PAA. Efficacy Testing Rapicide PA was tested at 850 ppm PAA under case conditions according to AOAC methods and other applicable standards for microbiological testing for germicidal efficacy. Tests demonstrated sporicidal, bactericidal, fungicidal, tuberculocidal and virucidal efficacy. 1. Sporicidal Response Curve A high level disinfection response curve was established by determining the sporicidal activity as a function of time. Silk suture loops, inoculated with Clostridium sporogenes, were tested according to AOAC method at time points of 2, 3, 4, 5, 6, and 7 hours. All the spore-carriers were disinfected in less than two hours as summarized in Table 1. Table 1. Efficacy of Rapicide PA against bacterial endospores at various exposure times Exposure Time (Hours) Number of Carriers with Survivors per 30 Carriers 2 0 3 0 4 0 5 0 6 0 7 0 2. AOAC Sporicidal Activity of Rapicide PA High-Level Disinfectant Three lots of Rapicide PA tested under case conditions according to the AOAC procedure at the MRC of 850 ppm of PAA using 720 carriers was shown to be sporicidal after exposure for 5.0 hrs at 30 o C (86 o F). 6

3. Confirmatory AOAC Sporicidal Activity of Rapicide PA High-Level Disinfectant Two lots of Rapicide PA tested under case conditions according to the AOAC procedure at the MRC of 850 ppm of PAA using 120 carriers, 30 each of all four types, was shown to be sporicidal after exposure for 5 hrs at 30 o C (86 o F). 4. Quantitative Tuberculocidal Activity of Rapicide PA High-Level Disinfectant Two lots of Rapicide PA tested under case conditions at the MRC of 850 ppm PAA was shown to be tuberculocidal after 5 minutes at 30 o C (86 o F) against Mycobacterium bovis (var. BCG). Rapicide PA was found to kill > 7.0 x 10 6 colony forming units in three minutes. This data supports the high level disinfection claim of 5 minutes for Rapicide PA. 5. AOAC Use Dilution Test Vegetative Bacteria Rapicide PA was tested under case conditions at the MRC of 850 ppm PAA at 30 o C (86 o F) against Pseudomonas aeruginosa, Staphylococcus aureus, Salmonella enterica, inoculated onto stainless steel cylinders, according to the AOAC Use Dilution Test standards and shown to be effective after 5 minutes. Rapicide PA showed total kill of all three bacteria with the claimed high level disinfection contact time of 5 minutes. 6. Fungicidal Activity Rapicide PA was tested under case conditions at the MRC of 850 ppm PAA at 30 o C (86 o F) against Trichophyton mentagrophytes according to the AOAC Fungicidal Activity of Disinfectants Test and shown to be effective after 5 minutes. Rapicide PA showed total kill of the test organism with the claimed highlevel disinfection contact time of 5 minutes. 7. Virucidal Activity Two lots of Rapicide PA tested under case conditions at the MRC of 850 ppm PAA was shown to be effective after 5 minutes at 30 o C (86 o F) against Poliovirus Type 2, Herpes Simplex Virus Type 1, and HIV-1 Type 1viruses. This supports the claimed virucidal high-level disinfection contact time. 7

8. Summary of Efficacy Data Table 2. Summary of Efficacy Testing TESTS Organism Results Sporicidal Clostridium sporogenes spores Total Kill Sporicidal Bacillus subtilis spores Total Kill Tuberculocidal Mycobacterium bovis (BCG) Total Kill Virucidal Polio virus type 2 Complete Inactivation Virucidal Herpes Simplex virus type 1 Complete Inactivation Virucidal Human Immunodeficiency Virus type 1 Complete Inactivation Fungicidal Trichophyton mentagrophytes Total Kill Bactericidal Pseudomonas aeruginosa Total Kill Bactericidal Staphylococcus aureus Total Kill Bactericidal Salmonella enterica Total Kill Simulated Use Mycobacterium terrae >6 log Reduction In-Use GI Tract Normal Flora Total Kill 9. Simulated Use Tests Simulated use testing with endoscopes that are difficult to disinfect was performed to show that Rapicide PA high-level disinfection can disinfect in 5 minutes. High-Level Disinfection The exterior surface and interior channels of endoscopes Models BF-P30 (bronchoscope), GIF-100 (gastroscope) and XCF-H160AYL (colonoscope) were inoculated with >10 7 CFU of Mycobacterium terrae. The scopes were then dried for at least one hour at ambient temperatures and subjected to a 5 minute disinfection cycle at 30 o C (86 o F) in a Medivators Advantage Plus AER using Rapicide PA under worst case conditions at the MRC of 850 ppm PAA. The study was repeated three times with each endoscope. All nine test runs showed a greater than 6-log reduction. These tests support the claimed high-level disinfection contact time of 5 min. 8

10. Clinical In-Use Tests of Rapicide PA A total of 15 endoscopes, five each of models GIF 180 (Gastroscope), CF 180AL (Colonoscope) and BF P40 (Bronchoscope) used in clinical procedures in an endoscopy clinic, were high-level disinfected with Rapicide PA. The endoscopes were pre-cleaned (following standard procedures at the clinic) and subjected to a 5 minute high-level disinfection cycle at 30 o C (86 o F) in an Advantage Plus AER using Rapicide PA under worst case conditions at the MRC of 850 ppm PAA. The exterior surfaces and interior channels of the endoscopes were then sampled for surviving bacteria. No bacteria were recovered from any of the endoscopes. MATERIAL COMPATIBILITY Rapicide PA High-Level Disinfectant is compatible with the following reusable devices and materials: flexible endoscopes, rubber, plastic, many types of metals (such as stainless steel, carbon steel, and aluminum). Rapicide PA High-Level Disinfectant is recommended for use with medical devices made from materials shown in Table 3 below. These devices may be damaged if cleaned with highly alkaline detergent, poorly rinsed after disinfection, stored wet, or dried at temperatures exceeding 40 C (105 F). TABLE 3: List of Compatible Materials Metals Plastics Elastomers Hastelloy Polyethylene Aflas 301 Stainless steel Polyvinylchloride Silicone Rubber 304 Stainless steel Teflon (PTFE) Viton 316 Stainless steel Polyurethane Santaprene Inconnel PolysuIfone EPDM Polyester Polycarbonate Nylon PVDF Polypropylene PETG Acetal The compatibility of Rapicide PA has been examined both by running intensive scope exposure tests, and also by doing materials compatibility testing versus the "use" solution (as well as the pure part A and part B). In addition, biocompatibility testing has been done in order to demonstrate the rinsing of the chemical components from the scopes. 9

The endoscope compatibility testing was run using Olympus model TJF-1 and model CF-100l scopes, subjecting them to 500 cycles on the Advantage Plus. Each cycle consisted of a 2 minute exposure to detergent, rinsing, a 6 minute disinfection cycle (worst case), followed by rinsing and alcohol. The scopes were inspected before and after the 500 HLD cycle run. The inspection was done by Surgical Repair Technologies (Eagan, MN), involving functional evaluation of angulation, control, biopsy, insertion tub, light guide, suction, light guide connector, eyepiece, image, light illumination, air/water function, and leak testing. No change was observed in physical appearance or functionality, and the scopes passed all leak tests. We performed chemical exposure lifetime testing on exposed components of the Advantage Plus. The exposure to the Use Solution (after mixing and diluting the parts A & B to the use dilution) was performed on metal, plastic and elastomer wetted components. The metal components included several types of stainless steel (SS 304, 301, 316), Inconnel springs, ceramic and glass. All components passed the testing. The plastic and elastomer component included EPDM, PETP, nylon, PFA, PP, PTFE, PVC, PVDF, Viton, Silicone, santoprene, PS, and proprietary materials such as Iglidur and Gelcoat. All components passed the testing. Chemical exposure lifetime testing was also performed on materials that would be exposed to Part A alone (undiluted) and also part B alone (undiluted). These materials included stainless steel (316) and Hasteloy, PVC, PP, EPDM and Aflas. All components passed the testing, except for slight effects on two EPDM components (which are part of preventative maintenance and were replaced). The chemical exposure testing for both the Use Solution and Part A or Part B alone included dimensional, weight, visual and infrared analysis. In addition to the chemical compatibility testing, a study was done to test the toxicity of rubber components (from Olympus parts) that were exposed to 100 HLD cycles. These materials are from the distal end of an endoscope, which will make patient contact. It was concluded that the Rapicide PA had a non-toxic effect on the rubber parts, based on results of cytoxicity testing after the 100 cycles. This test is governed by ANSI/AAMI/ISO 10993-5:1999. Biocompatibility testing was also done to examine the residuals on endoscopes after 1 and 100 cycles of HLD exposure. It was concluded that the Advantage Plus adequately rinses detergent and disinfectant residues from the surfaces of the endoscope, making it safe for both patients and hospital staff. The above testing indicates the Rapicide PA is safe to use on endoscopes and the exposed materials. No effect was observed on the endoscope components or functionality. 10

TOXICITY Rapicide PA has been extensively tested for potential toxicity to both user (environmental) and patient. Summary of Environmental Toxicity Standard toxicological testing was performed to evaluate the possible toxicological effects from inhalation, oral consumption, eye contact, skin contact, dermal irritation, dermal sensitization and genotoxicity. Table 4 summarizes the environmental test results. Table 4: Summary of Environmental Toxicity Tests Test Test Results Acute Oral Toxicity (Rat) Acute Inhalation Toxicity (Rat) Primary Eye Irritation Acute Dermal Toxicity (Rabbit) Repeat Dermal Toxicity (Rat) Primary Skin Irritation (Rabbit) Skin Sensitization (Guinea Pigs) Genotoxicity (Ames) LD 50 > 5 g/kg LC 50 > 2.1 mg/kg Corrosive to ocular tissue May produce systemic effects at LD 50 > 2 g/kg Rapicide PA is not associated with observed signs of toxicity at 1000 mg/kg Not an irritant Not an allergen Non-mutagenic Summary of Patient Toxicity Standard toxicological tests were performed to evaluate the possible toxicological effects by cytotoxicity, mucosal irritation and hemolysis. Table 5 summarizes the patient test results. 11

Table 5: Summary of Patient Toxicity Tests Test Cytotoxicity (Rapicide PA) Cytotoxicity (A-rubber) Hemolysis Mucosal Irritation Acute Intravenous Toxicity Test Results Non-toxic at 1:500 dilution Non-toxic Non-Hemolytic at 1:1000 dilution Minimal irritant LD 50 > 5 g/kg 12

BIOCOMPATIBILITY - A study was conducted to determine the amount of PAA and HP residue that remain on endoscopes after reprocessing in an AER with Rapicide PA High-Level Disinfectant and rinsing with water. The study used Rapicide PA at the maximum possible use-solution concentration of PAA and exposed three pediatric colonoscopes to the longest labeled exposure time, a five hour cycle. The pediatric colonoscope was used in the study because it is representative of an endoscope that is most difficult to rinse based on its long narrow channels and large surface area. Following a five hour cycle in the Medivators Advantage Plus AER, the three endoscopes were immediately and exhaustively extracted for 24 hours to remove all PAA and HP residues. This was followed by an additional 4 hour residue extraction. From the extractions, a worst case of human observable exposure dose was calculated to be 0.9 mg/kg and 1.11 mg/kg for PAA and HP, respectively. The worst case human observable exposure dose limits was compared to the reported rat Repeat Dermal No Observed Effect Level (NOEL) doses of 4.4 mg/kg and 5.4 mg/kg for PAA and HP, respectively. The risk to humans is shown to be close to five fold lower than to the rat Repeat Dermal NOEL. These extractions were performed over a 24 hour period, which is a great deal longer than a typical endoscopy procedure of 15 minutes to two hours. In relating these residual values to realistic patient exposure, we conclude that these PAA and HP levels are not toxic if introduced into the human body. 13

COMPATIBILITY WITH ENDOSCOPES (500 CYCLES) A Medivators Advantage Plus was operated with Rapicide PA in two types of endoscopes for a minimum of 500 cycles. The AER was set to the high end of the temperature parameters 32º ± 2º C for worst case simulation. At the end of the cycles the endoscopes were examined by Surgical Repair Technologies. No damage was detected, and the endoscopes functioned properly, demonstrating that Rapicide PA High- Level Disinfectant is compatible with flexible endoscopes (Minntech QP 201745). PACKAGING CONFIGURATION Rapicide PA is available in the following packaging configuration. One package contains 20 liters of usesolution. Packaging: 4 Bottles per Case (20 Liters) 2 Bottles of Part A X 5 Liters 2 Bottles of Part B X 5 Liters each bottle weighs approximately 10.5 lbs. 14