INFINITY MAX TILE SPECIFICATION

Similar documents
SECTION ATHLETIC AND RECREATIONAL SURFACING. A. ASTM C 67 - Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile.

A. Section Cast-in-Place Concrete: Concrete subsurface. A. ASTM D Standard Test Methods for Rubber Property Compression Set.

PRODUCT GUIDE SPECIFICATION

Product Guide Specification

SAN FRANCISCO UNIFIED SCHOOL DISTRICT FACILITIES, DESIGN AND CONSTRUCTION ADDENDUM NO. 1

Product Guide Specification

SECURE LOCK INTERLOCKING TILES Product Guide Specification

SECURE LOCK INTERLOCKING TILES Product Guide Specification

Product Guide Specification

Product Guide Specification

Zeager Bros. Inc. Middletown, Pa / Zeager Hardwood Co. Franklin, Ky Revised - August, 2012 by ASC

Ceiling Tiles C200B - Specification

SECTION THERMAL INSULATION

SECTION RESILIENT ATHLETIC SURFACING. B. Related Sections: Section(s) related to this section include:

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

Regupol AktivPro RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER MOLDED TILES

1. Amarco Products Athletic Recycled Rubber Sports Flooring Rolls and Interlocking Tiles 2. Adhesives

Powerdek Fleck. SECTION Resilient Athletic Flooring

Division 9: Section RESILIENT ATHLETIC SURFACING (Regupol AktivLok Recycled Rubber)

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

Everlast Basic Rolls and Tiles GUIDE SPECIFICATIONS Ecore

ACOUSTICAL WALL TREATMENT SECTION 09840

A. Section Wood, Plastics and Composites.

Ecore Athletic Elevate Roster Interlocking Carpet Tile GUIDE SPECIFICATIONS Ecore

Blue Sky Interlocking Playground Tile - Product Guide Specifications

SECTION ORCHESTRA PIT FILLER

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation.

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

SECTION Blown Insulation THERMAL INSULATION

Regupol Aktiv RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER

SECTION (09800) - Suspended Acoustic Baffles. This Section is based on TECHLITE Accent Linear Ceiling Baffles.

1. ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Rubbers and Thermoplastic Elastomers-Tension.

SECTION SPRAY FOAM INSULATION

SECTION Resilient Athletic Flooring

SECTION ALUMINUM WINDOWS

Fastrack Rolls and Interlocking Tiles GUIDE SPECIFICATIONS Centaur

SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS

SECTION WINDOW FILM. A. Section Windows; windows to receive architectural window film.

DIVISION 9 - SECTION ECOSilence Recycled Rubber Sound Underlayment US Patent No. RE 41,945

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

SECTION Arisfor WallGuard

SECTION PHENOLIC LOCKERS AND BENCHES. B. Section Gypsum Board Area Separation Wall Assemblies.

Ecore Athletic Elevate BOUNCE 2 GUIDE SPECIFICATIONS Ecore

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.

Action ReFlex Spin Resilient Floor System

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SECTION SOLID SURFACE COUNTERTOPS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

SECTION SPRAY FOAM INSULATION

HAWORTH PORCELAIN FLOORING SYSTEM CSI Specifications 03/29/2017. A. Concrete work and concrete floor sealer is specified in Section

SECTION COMPOSITE CORE ACOUSTICAL PANEL CEILINGS. Sound-Rite Inc. #9, rd Avenue NE Calgary, AB T2A 7P3

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SECTION SAFETY AND SECURITY FILM. A. Section Steel Doors and Frames: New doors with glazing to receive film.

SECTION SAFETY AND SECURITY FILM. A. Section Steel Doors and Frames: New doors with glazing to receive film.

Ecore Athletic Stacked Performance Collection Rolls and Interlocking Tiles GUIDE SPECIFICATIONS Ecore

Everlast Smash Tile GUIDE SPECIFICATIONS Ecore

Training Ground with Nike Grind RubberX GUIDE SPECIFICATIONS Ecore

1. PRODUCT NAME APOLLO FITNESS TILES

Foamed-in-place insulation Sprayed insulation. Spray Foam Insulation for Residential Building Envelope Insulation

SECTION ACOUSTICAL PLASTER CEILINGS

No Fault Safety Surface & SAF DEK for Playgrounds Product Specification

SECTION BRICK FACED ARCHITECTURAL PRECAST CONCRETE. A. Section Cast-In-Place Concrete: Concrete, reinforcing, anchors, etc.

CSI Exceed PART 1.0 GENERAL. plae.us SUMMARY 1.2 REFERENCES

SECTION STRUCTURAL INSULATED PANELS

SECTION Resilient Athletic Flooring

ECOmax Tiles 1 and 2-1/2 GUIDE SPECIFICATIONS Ecore

SECTION ACOUSTICAL PLASTER CEILINGS

by Rollfab Metal Products

Union County Vocational - Technical Schools Scotch Plains, New Jersey

ECOfit Rolls GUIDE SPECIFICATIONS ECORE Commercial Flooring

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

ECOfit Rolls GUIDE SPECIFICATIONS Ecore Commercial Flooring

SECTION ( ) PVC Paneling. A. Section ( ) Special Wall Surfacing

ECOnights Rolls and Tiles GUIDE SPECIFICATIONS Ecore Commercial Flooring

WoodTrends Acoustical Wood Ceiling System BASIC Specification

SuperTile GUIDE SPECIFICATIONS Signature Sports Flooring

Marlite Guide Specification 2/24/2017 Surface Systems - MAP375 System SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

SECTION SAFETY AND SECURITY WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here)

Construction Standards PAGE

SECTION SOUND-ABSORPTIVE PANELS

Phenolic Exterior Wall Cladding

SECTION EPOXY TERRAZZO TILE WITH RECYCLED GLASS MATRIX

08620 UNIT SKYLIGHTS Tufflite double polycarbonate glazed Frb

Pinnacle 2 Carpet Tile GUIDE SPECIFICATIONS Ecore

MondoArmor (18mm) Technical Specification Sheet

SECTION ACOUSTICAL PLASTER CEILINGS

Reinforced California Architectural Roof Pavers, Pedestal Supported

A. This section includes pre-finished Higuera Hardwoods bamboo flooring and accessories for floors and stairs.

REQUEST FOR PROPOSAL Ballistic Film

HAWORTH TECCRETE WITH PORCELAIN FLOOR COVERING - CSI Specifications 04/25/2017

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION

Product Guide Specification Pliteq GenieMat FF06, GenieMat FF10, GenieMat FF17, GenieMat FF25, GenieMat FF50, GenieMat FF75

SofTILE KrosLOCK TECHNICAL SPECIFICATIONS

SECTION MULTI-USE COMPOSITE ALUMINUM PANELS

SECTION PRE-ENGINEERED BUILDING INSULATION

Advance NG (6mm) Technical Specification Sheet

Transcription:

www.infinityperformance.com 888-479-1017 INFINITY MAX TILE SPECIFICATION Physical Specification: INFINITY MAX configurations consist of an interlocking, dual durometer flooring system consisting of a high density wear layer surface permanently molded to an underlayment incorporating 113 pedestals per tile to maximize shock absorbency and traction underfoot in wet and dry conditions as well as an omni-directional locking design to promote ease of installation. Component Specification: INFINITY MAX is a factory molded modular surfacing system composed of high quality TPV (ThermoPlastic Volcanisate) rubber granules bound in both underlayment and wear surface with a wear and weather resistant polyurethane. Rubber granules in both wear surface and underlayment are specially blended to enhance tile strength, durability and energy absorption characteristics. Tile Construction: INFINITY MAX 1. Evenly distributes fitness equipment weight over 113 pedestals per tile 2. Omni-Directional Locking Design: Locks the system firmly in place without adhesive 3. Wear Layer: High compression wear layer Type: Virgin TPV rubber granules. INFINITY MAX TILE SPECIFICATION Product Data Dimensions (78 F.): 1.25 x 23.75 x 23.75 ± 1/8 Wear Surface Density 90 lb./ft 3 min. Coefficient of Thermal Expansion 1.1 x 10-3 in/ft/ F Weight 21.5 lbs./tile or 5.3 lb./ft 2 Physical Data Test ASTM Acoustical A09-009 EC423 / SAA =0.14, NRC = 0.15 E795 Acoustical TL08-363 E90 / E413 STC = 53 Acoustical IN08-050 E492 / E989 IIC 59 Acoustical IFC09-002 E2179 DELTA IIC 26 IICc 54 Tensile Strength D412 107 lb/in 2 min Elongation at Break D412 165% minimum Compression Deflection D1667 29.5 lb/in 2 to 25% Compression Compression Set D395 4.37% Permanent Set Impact Insulation Class E49 > 50 Tear Resistance D624 33.1 lb./in 2 min. Slip Resistance E303 Dry: 102, Wet: 62 Coefficient of Friction (Slip Resistance) D2047 Dry.81 Wet.82 Noise Reduction Coefficient C423 0.10 sabine/ft 2 Rubber Deterioration / Air Oven D573 No Deterioration Critical Radiant Flux E648 Class II -.34 Flammability E648 Class 2 Flammability (Burning Pill Test) D2859 Passed Flammability Roof Covering E108 Class A Freeze Thaw C67 No Deterioration

SECTION 02790 ATHLETIC AND RECREATIONAL SURFACING 1.1 QUALITY ASSURANCE A. Manufacturer's Qualifications: Manufacturer shall meet at least one of the following requirements. 1. Continuously engaged in manufacturing of surfacing products of similar type to that specified, with a minimum of 10 years successful experience. 2. Furnished a minimum of 1,000,000 square feet per year of surfacing products of similar type to that specified. B. Installer's Qualifications: 1. Successful experience in installation of surfacing of similar type to that specified, with a minimum of 25 projects completed within last 5 years. 2. Employ persons trained for installation of surfacing products. 3. Must be installed by the Manufacturer s own installation crew or Manufacturer Approved Installer. 1.2 DELIVERY, STORAGE, AND HANDLING A. Delivery: Deliver materials to site in manufacturer's original, unopened containers and packaging, with labels clearly identifying product name and manufacturer. B. Storage: 1. Store materials in accordance with manufacturer's instructions. 2. Store materials in a dry storage area at a minimum temperature of 50 degrees F (10 degrees C) for a minimum of 48 hours before installation. 3. Store materials to be installed indoors at the ambient temperature of the installation location for a minimum of 48 hours before installation. 4. Protect materials from direct sunlight before installation. 5. Store adhesive in a dry area at a minimum temperature of 50 degrees F C. Handling: Protect materials during handling and installation to prevent damage. D. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction. 1.3 PROJECT CONDITIONS A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits. 1. Material Temperature: Ensure surface temperature of surfacing tiles is a minimum of 50 degrees F (10 degrees C) at time of installation. 2. Air Temperature for Interior Installations: Ensure air temperature is at the same temperature as anticipated during normal operation. 3. Air Temperature for Exterior Installations: Ensure air temperature is a minimum of 40 degrees F (4 degrees C) and a maximum of 90 degrees F (32 degrees C) for a minimum of 24 hours before and during installation.

1.4 SUBMITTALS A. Submit under provisions of Section 01300. B. Product Data: Manufacturer's data sheets on each product to be used, including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods. C. Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns. D. Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns. E. Certificate of Compliance: Submit manufacturer's certificate of compliance indicating materials comply with specified requirements. F. Manufacturer's Project References: 1. Submit list of successfully completed projects. 2. Include project name and location, name of architect, and type and quantity of surfacing furnished. G. Installer's Project References: 1. Submit list of successfully completed projects. 2. Include project name and location, name of architect, and type and quantity of surfacing installed. H. Maintenance Instructions: Submit manufacturer's maintenance and cleaning instructions. I. Warranty: Submit manufacturer's standard warranty. 1.5 WARRANTY INFINITY MAX is warranted for a period of 10 (ten) years against premature deterioration, manufacturer s defects as well as any damage whatsoever to the INFINITY MAX material due to dropping free weights directly on the INFINITY MAX. The warranty issued for this project must have the following statement included in the material warranty: Seller warrants that any damage to the INFINITY MAX material due to dropping free weights on the INFINITY MAX will be covered under this warranty for a period of ten (10) years.

PART 2 PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Infinity Performance Inc., which is located at: 6735 N. Meridian St., Indianapolis, IN 46260. Email: info@infinityperformance.com; Web: www.infinityperformance.com B. Requests for substitutions will be considered in accordance with provisions of Section 01600. 2.2 FITNESS FLOORING A. INFINITY MAX as manufactured for Infinity Performance Inc. 1. Manufactured with a TPV rubber granule on the wear layer to provide a speckled appearance. Any combination of colors can be used to create a speckled appearance. 2. Blend: 90 percent color, 10 percent black. B. Tile Construction: 1. Evenly distributes fitness equipment weight over 64 pedestals per tile. 2. Omni-Directional Locking Design: Locks the system firmly in place with or without the use of adhesive. 3. Wear Layer: High compression wear layer. a. Type: Virgin TPV rubber granules. Nominal 0.250 inch (6 mm) thick. 4. Size: 23.75 inches by 23.75 inches, plus or minus 1/8 inch 5. Thickness: 1.25 inches 6. Freeze Thaw, ASTM C 67: No deterioration. 7. Rubber Deterioration / Air Oven, ASTM D 573: No deterioration. 8. Slip Resistance: a. ASTM E 303: 1) Dry: 102. 2) Wet: 62. b. ASTM D 2047: 1) Dry: 0.81. 2) Wet: 0.82. 9. Compression Deflection, ASTM D 1667: 29.5 psi (2.1 kgs/sq. cm) to 25 percent compression. 10. Compression Set, ASTM D 395: 4.37 percent permanent set. 11. Tensile Strength, ASTM D 412: 107 psi (7.5 kgs/sq. cm). 12. Elongation at Break, ASTM D 412: 165 percent. 13. Tear Strength, ASTM D 624: 33.1 psi (2.3 kgs/sq. cm). 14. Wear Surface Density (Durability): 90 pcf (961 kg/cu. m) minimum. 15. Critical Radiant Flux, ASTM E 648: Class II,.34 16. Flammability: a. Burning Pill, ASTM D 2859: Pass. C. Accessories: 1. Corners: a. Prefabricated outside and inside corners. b. Material: Same as surfacing tiles. 2. Ramps: a. Prefabricated Ramps b. Prefabricated ADA-Compliant Ramps

c. Material: Same as surfacing tiles. PART 3 EXECUTION 3.1 EXAMINATION A. Do not begin installation until substrates have been properly prepared. B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. 3.2 PREPARATION A. Clean surfaces thoroughly prior to installation. B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. C. Subsurface: Install adhesive at the perimeter of the installation as recommended by the manufacturer. D. Variations in Elevation: Repair variations in elevation of completed subsurface greater than plus or minus 1/4 inch (6 mm) over 10 feet (3 m) in any direction. 3.3 INSTALLATION A. Install surfacing in accordance with manufacturer's instructions at locations indicated on the Drawings. B. Ensure prepared subsurface is dry and clean. C. Layout surface pattern in accordance with manufacturer's instructions. 3.4 CLEANING A. Clean tiles in accordance with manufacturer's instructions. 3.5 PROTECTION A. Protect completed tiles from damage during construction. END OF SECTION The products in this specification are based on the products of: Infinity Performance, Inc. 6735 N. Meridian Street Indianapolis, IN 46260 Toll Free: (888) 479-1017 Tel: (317) 479-1017 Fax: (317) 479-1018 E-mail: info@infinityperformance.com Web: www.infinityperformance.com