Architects and Designers Should Understand Loads Exerted By Rolling Doors

Similar documents
PRODUCT EVALUATION Effective Date: June 1, 2013 GDR-39

PRODUCT EVALUATION Effective Date: June 1, 2013 GDR-40

SECTION Coiling Doors and Grilles Model 4320

Submit shop drawings in accordance with Vale Specification SPEC

Aluminum Perforated Rolling Door

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

FABRICOIL BASIC January 10, 2006

SECTION ROLLING STEEL DOORS

Model STORM GRILLE Brick or Straight Pattern High Stress Rolling Grilles

Stone and Masonry Veneer

SECTION NON-STRUCTURAL METAL FRAMING

PRODUCT SPECIFICATION

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Rolling SheetDoor Systems

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

MASONRY WALL DATA: Wall Height = ft. Nominal Wall Thickness = 8.00 in. Depth to c.g. Steel, Wall = 3.81 in.

Installation, Operation and Maintenance Manual

SECTION OVERHEAD COILING SHUTTERS

Submit shop drawings in accordance with Vale Specification SPEC

COUNTER-SHUTTER FIRE DOOR

Masonry Wall Bracing. A Simplified Approach To Bracing Masonry Walls Under Construction. Masonry Bracing Task Force.

Cavity ShAftwall System

SECURITY WITH SOPHISTICATED STYLE

SECTION OVERHEAD COILING DOORS 610 SERIES SERVICE DOORS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

ENGINEERED POWER SOLUTIONS

WALL MOUNTED ARTICULATING JIB CRANE

OPTIONS ARE LISTED IN RED, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR MODIFICATIONS.

LLOYD INDUSTRIES INC. DAMPER INSTALLATION INSTRUCTIONS

SECTION OVERHEAD COILING DOORS 610 SERIES SERVICE DOORS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

ESTIMATING/TAKE-OFF AND ORDERING GUIDE

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

POST FRAME BUILDING STANDARDS

Model FIRE INTEGRAL SPLIT FRAME Curved or Flat Slats Rolling Counter Doors

ALTERNATE DESIGN METHODOLOGY FOR UNREINFORCED MASONRY BUILDINGS

SECTION OVERHEAD COILING DOORS STORMTITE 620 SERIES SERVICE DOORS

SHRC SHELTERS STACI CUCCIO, FLINT HOLBROOK, KEVIN ROEWE, & JARED SWART

Building Division Informational Handout

SECTION OVERHEAD COILING DOORS STORMTITE 620 SERIES SERVICE DOORS

GUIDE FOR EVALUATING BLAST RESISTANCE OF EXISTING UNDEFINED ARCH-TYPE EARTH-COVERED MAGAZINES

STANDARDIZED STRUCTURES

SECTION Coiling Counter Shutters

SECTION Coiling Counter Shutters

HAMBRO COMPOSITE FLOOR SYSTEM

UNIFIED FACILITIES GUIDE SPECIFICATIONS

181 Fremont San Francisco, CA. Tech Report 3 10/17/2014. PSUAE Structural Option Advisor: Dr. Thomas Boothby

The following are details of the code requirements of the 2015 International Residential Code for single-story decks.

SECTION [ ] ROLLING STEEL DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

STRUCTURAL CALCULATIONS EXTERIOR SIDING CLADDING SYSTEM FLUSH PANEL SIDING SYSTEM AND LAPPED PANEL SIDING SYSTEM

1. Section "Metal Fabrications" for miscellaneous steel supports.

SECTION OVERHEAD COILING DOORS 790 SERIES OVERHEAD COILING SHEET DOORS

Single Deflection Track Selection

TITEN HD Heavy Duty Screw Anchor for Concrete & Masonry

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

RATING: Consult factory for availability Consult factory for availability

SECTION SECTIONAL OVERHEAD DOORS

1 Introduction Structural Concept Recommended Clip Spacing & Fastener Data... 5

HAMBRO COMPOSITE FLOOR SYSTEM

VAULTED STRUCTURES STABILITY CALCULATIONS

WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947

SECTION SECTIONAL OVERHEAD DOORS

ANALYSIS AND DESIGN OF MOMENT RESISTING MIDWALL BY THE STEEL NETWORK, INC.

Window Evaluation. Subject: Series 200 Horizontal Sliding Impact-Resistant Windows. Report Rendered to:

Recessed Door Header Engineering PSBox8LT(5-5/8") 22ga.

SECTION SECTIONAL OVERHEAD DOORS

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

SECTION UNIT MASONRY

Mandatory Wood Frame Soft-story Retrofit Program STRUCTURAL DESIGN GUIDELINES

SECTION OVERHEAD COILING DOORS

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

Bautex Wall System. Design & Engineering Guide

SECTION ELECTRIC FOUR FOLD DOORS MODEL 46 FLAT SHEETED

SECTION Overhead Coiling Doors

F-SERIES: F SPECIFICATIONS Four-Fold Door Systems

Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

1600 WALL SYSTEM 2 ESTIMATING/TAKE-OFF AND ORDERING GUIDE (16 Pages) E.C.# (09/09/13)

Blast Curtain Wall Installation Analysis

WIND SPEED AND DESIGN CRITERIA FOR FLEXIBLE FACE SIGNS CONSTRUCTED OF ABC EXTRUSIONS

RAOUL WALLENBERG HIGH SCHOOL SECURITY COILING GRILLE SFUSD PROJECT NO SAN FRANCISCO UNIFIED SCHOOL DISTRICT SECTION 08330

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SECTION ALUMINUM GATES

SECTION [ ] SECURITY GRILLES. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION [ ] SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

UNIFIED FACILITIES GUIDE SPECIFICATION

SECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SBCCI PUBLIC SAFETY TESTING AND EVALUATION SERVICES INC.

Reinforced Concrete Tilt-Up Wall Panel with Opening Analysis and Design (ACI 551)

SECTION STAINLESS STEEL WALL PANELS

Section G1. Design of Cast-In-Place Box Conduits

SECTION ALUMINUM WINDOWS

Chuck Brooks, P.E., P.Eng. C&S Engineers

Structural Engineering, Mechanics, and Materials. Preliminary Exam - Structural Design

SECTION SECTIONAL OVERHEAD DOORS

Panduit Corporation Tinley Park, Illinois. Outset and Inset Cabinets Seismic Load Rating and Anchorage Design

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

TEK 14-17: CONCRETE MASONRY CANTILEVER HIGHWAY NOISE BARRIER WALLS (1986)

SECTION SECTIONAL OVERHEAD DOORS

Agricultural Hall and Annex East Lansing, MI. Structural Design. Gravity Loads. 1- Based on US Standards

Transcription:

rchitects and Designers Should Understand Loads Exerted y Rolling Doors It is important for architects and building designers to understand the loads that rolling doors exert on the wall above the opening and on the jamb. Dead loading would include the weight of the curtain, counterbalance, hood, operator, etc., that is supported by the wall above the opening. Live loading would result from wind loads that act on the door curtain. On doors without windlocks, the only wind load force that the curtain exerts on the guides is normal to the opening. On doors with windlocks, there is an additional load that is parallel to the opening. This load is the catenary tension that results when the curtain deflects sufficiently to allow the windlocks to engage the windbar in the guide. This force acts to pull the guides toward the center of the opening. The door is exposed to a positive load by wind on the outside of the building. negative load on the door comes from inside of the building. alculating the parallel force involves several variables, most prominent of which are the width of the opening and the specified wind load. It is also important to note that the door must withstand both positive and negative wind loads. Including these forces in the design of the jamb and its supporting structure can help prevent a jamb failure and allow the building to fully withstand its specified wind load requirements. It should be noted that catenary forces computed by rolling door manufacturers assume that vertical jambs are rigid. Flexibility of vertical jambs could affect the magnitude of such catenary forces and the performance of the door.. The DSM rolling door manufacturers can provide you with a guide data sheet for the rolling doors for your next project. opies of the forms manufacturers can use are included with this Technical Data Sheet. Please note that "rolling sheet doors" are excluded from this Technical Data Sheet, and are to be addressed separately. The following four site conditions are to be avoided: uilding designed with roll-formed jambs that cannot handle the normal and parallel forces exerted by the door guide assemblies. The jambs will rotate under wind load and the door curtain can be blown out of the guides. Openings on the steel buildings must have jambs designed for rolling door loads. Wall above the opening not designed to handle the total hanging dead load. Face of wall mounted doors may extend above the opening for 12 to 30 inches. The door guide wall angles must be mounted to the wall above the opening to support the door. When the door has a hood to cover the coiled curtain and counter-balance, some provision must be made to fasten the top of the hood and hood supports to the wall. oncrete masonry unit wall without concrete and rebar reinforced jambs cannot handle the forces imposed by the door. The design of a steel reinforced MU jamb should have at least a 2500 psi concrete rating. rebar free location for installation of expansion anchors is preferred. 8/1/01 Rev. 4/11 Page 1 of 7 This sheet is reviewed periodically and may be updated. Visit www.dasma.com for the latest version.

ustomer: GUIDE DT SHEET (Face Mounted Door Without Windlocks) DTE: Door Model: Slat Type: Gauge: Serial No.: Job: Opening Size: Type of Guide: : P.S.F. Note: ll forces are pounds per foot of height. "Z" Guide Note: ll forces are pounds per foot of height. "E" Guide 8/1/01 Rev. 4/11 Page 2 of 7 This sheet is reviewed periodically and may be updated. Visit www.dasma.com for the latest version.

GUIDE DT SHEET (Face Mounted Door With Windlocks) DTE: Door Model: Slat Type: Gauge: Serial No.: ustomer: Job: Opening Size: Type of Guide: : P.S.F. Windlock Windbar Note: ll forces are pounds per foot of height. "Z" Guide Windbar Windlock Note: ll forces are pounds per foot of height. "E" Guide 8/1/01 Rev. 4/11 Page 3 of 7 This sheet is reviewed periodically and may be updated. Visit www.dasma.com for the latest version.

Door Model: Slat Type: Gauge: Serial No.: ustomer: GUIDE DT SHEET DTE: Job: Opening Size: : P.S.F. (etween-jamb Mounted Doors Without Windlocks) Note: ll forces are pounds per foot of height. 8/1/01 Rev. 4/11 Page 4 of 7 This sheet is reviewed periodically and may be updated. Visit www.dasma.com for the latest version.

GUIDE DT SHEET (etween-jamb Mounted Doors With Windlocks) DTE: Door Model: Slat Type: Gauge: Serial No.: ustomer: Job: Opening Size: : P.S.F. Windbar Windlock Note: ll forces are pounds per foot of height. 8/1/01 Rev. 4/11 Page 5 of 7 This sheet is reviewed periodically and may be updated. Visit www.dasma.com for the latest version.

d Headroom DL (Dead Load) Opening Height Opening Height DL (lbs.) Headroom d Page 2 of 2 January 2004 Page 2 (pplies to Doors With and Without Windlocks) 8/1/01 Rev. 4/11 Page 6 of 7 This sheet is reviewed periodically and may be updated. Visit www.dasma.com for the latest version.

uilding designed with tilt-up concrete panel walls that include steel jambs not securely attached to the concrete panels. Thus, the jambs cannot handle the forces imposed by the door. The steel jambs must be securely fastened to the wall along the full height of the opening. 8/1/01 Rev. 4/11 Page 7 of 7 This sheet is reviewed periodically and may be updated. Visit www.dasma.com for the latest version.