ZOLL Document Number: 90E0004 Page 5 of 15 Maintenance of Quality Records

Similar documents

Documenta tion and Records

Correspondence Between ISO 13485:2016 and 21 CFR Part 820 QMS Requirements

U. S. Department of Energy. Consolidated Audit Program Treatment, Storage and Disposal Facilities. Checklist 1 Quality Assurance Management Systems

FDA 21 CFR Part 820 vs. ISO 13485:2016 Comparison Table created by greenlight.guru

REQUIREMENTS FOR SAFETY RELATED (ASME AND NON-ASME) ITEMS OR SERVICES

Leading Practices on Compliance Series: Design History File (DHF): Tips for Creating a Successful DHF Tuesday, November 27, :00 1:00 pm Eastern

GCP Basics - refresher

Identifier Version Author SOP 8.0 Moon, Darci Title: (QMS-SOP) - Global IT Document Control SOP APPROVALS

C Control of Records 08/ of 6

Food and Drug Administration, HHS Pt Sec Scope Definitions Quality system.

21 CFR Ch. I ( Edition) Personnel Design controls Identification Traceability.

INS QA Programme Requirements

NQA-1 Graded Approach, 55-Gallon Drum Summary

Wilson-Hurd ATF Quality Manual

ISO 9001:2015 QUALITY MANAGEMENT SYSTEM POLICIES AND PROCEDURES

PART 820 QUALITY SYSTEM REGULATION. 21 CFR Ch. I ( Edition)

CUSTOMER AND SUPPLIER ROLES AND RESPONSIBILITIES FOR 21 CFR 11 COMPLIANCE ASSESSMENT. 21 CFR Part 11 FAQ. (Frequently Asked Questions)

QUALITY MANUAL ECO# REVISION DATE MGR QA A 2/25/2008 R.Clement J.Haislip B 6/17/2008 T.Finneran J.Haislip

External Provider Quality Requirements QCS-001 Processing Sources

AAMI Quality Systems White Paper: Comparison of 21 CFR Part 820 to ISO 13485:2016 1

ISO9001 QUALITY POLICY MANUAL

QUALITY MANAGEMENT SYSTEM POLICIES AND PROCEDURES

Vendor Qualification Survey

The Standard Illustrations ISO The International Standard for Quality Management Systems. Year 2000 Edition. Leland R.

Quality Manual Revision: C Effective: 03/01/10

WARNING LETTER CMS #

25 D.L. Martin Drive Mercersburg, PA (717)

ASA-100 QUALITY MANUAL

Good Documentation Practices. Documentation Requirements For Regulated Environments

SUPPLIER QUALITY SYSTEM SURVEY

AAMI Quality Systems White Paper

Quality System Regulation (QSR) Training

Addressing Key FDA Citations with Training. Align UL EduNeering Courses to Top FDA Warning Letter Topics

Supplier Quality System Survey

Helical Products Company

Document Number: QM001 Page 1 of 19. Rev Date: 10/16/2009 Rev Num: 1. Quality Manual. Quality Manual. Controlled Copy

Internal Auditing and Control of Nonconforming Work

Self-Audit Checklist

Page 1 / 11. Version 0 June 2014

National Shellfish Sanitation Program (NSSP) Guide for the Control of Molluscan Shellfish: 2017 Revision

CORPORATE QUALITY MANUAL

SUPPLIER QUALITY SYSTEM SURVEY

SECTION L QUALITY ASSURANCE. 1) designating and managing quality control functions, including:

Electro-Miniatures Corp. 68 West Commercial Ave. Moonachie New Jersey Phone: Fax:

Supplier Quality Requirements SQR-1.0 Rev. 3

Quality Control Procedures QCP 13.0 Page 1 of 6

SUPPLIER SURVEY FORM Instructions

ISO 9001: 2000 (December 13, 2000) QUALITY MANAGEMENT SYSTEM DOCUMENTATION OVERVIEW MATRIX

QUALITY AGREEMENT. The following Agreement has been concluded between

PURCHASING & RECEIVING INTERNAL AUDIT CHECKLIST

PRODUCTION SUPPLY INCORPORATED. QUALITY ASSURANCE POLICY MANUAL (Mil-I-45208A) # QAD REV. A

Association of American Railroads Quality Assurance System Evaluation (QASE) Checklist Rev. 1/12/2017

FO-5 PR-1, FO-1,2 PR-1 EM-6 PR-1, FE-1, NA-1 FO-10 FO-7, EM-2 EM-2. ISO Environmental Management Systems - Specification Yes.

25 D.L. Martin Drive Mercersburg, PA (717)

Basic Good Laboratory Practice. Christopher Jerome, B.Vet.Med., Ph.D

Quality Management System Manual

Compliance and Quality Monitoring: What, Why, When, and How

IPD Quality Management System Supplier Questionnaire Instructions

Role of Industrial Engineer in Compliance with FDA Regulations

Benchmark Connector Corp. Supplier Quality Survey

FEC QUALITY MANUAL. Federal Equipment Company River Rd. Cincinnati, Ohio

20 September 2017 Document No. QM-ISO revision T ASTRONAUTICS CORPORATION OF AMERICA S. AS 9100 and FAA QUALITY MANUAL. Proprietary Notice

9. Chapter 9: Data Management Procedures

This document applies to all personnel at The University of Iowa Dezii Translational Vision Research Group (DTVR).

Project Procedure 1.0 PURPOSE 2.0 SCOPE 3.0 REFERENCES 4.0 DEFINITIONS. No.: P /21/2012 PAGE 1 OF 8 INTERNAL QUALITY AUDITS

10 "Must-Haves" for the Life Sciences Learning Management System

A02 Assessment Rating Guide Revision 2.9 August 21, 2016

QUALITY MANUAL. Revision K. JADE PRECISION MEDICAL COMPONENTS, LLC 3063 B Philmont Avenue Huntingdon Valley, PA 19006

Electronic Records and Electronic Signatures (21 CFR Part 11)

Quality Manual TABLE OF CONTENTS APPROVAL SIGNATURE PAGE AMENDMENT RECORD SCOPE EXCLUSIONS 2.1 3

Counterfeit Control Plan for Electrical, Electronic and Electromechanical Parts

PROCEDURE CITY OF GRANDE PRAIRIE PURPOSE SCOPE PROHIBITIONS:

ARCHIVING REGULATIONS

Implementing Compliant Medical Device Best Practice Business Processes Using Oracle E-Business Suite

SESSION 14. Documentation Requirements and Management for Validation. 30 March Frits Vogt

Quality Manual ISO 9001:2000

QMS Team: MR and all HODs (Internal Auditors) MR March 10. Quality policy Define quality policy The Steering committee Objectives and targets

Medical QMS Quality Manual

Life Sciences Courseware. Knowledge. Performance. Impact.

SUPPLIER QUALITY ASSESSMENT

Control of Documents and Records. Internal Audit. Control of Non-Conformity, Corrective and Preventive Action

SQF 2000 Guidance. Guidance for Food Sector Category 4 Fresh Produce Pack House Operations. 1st Edition

BROOKHAVEN NATIONAL LABORATORY SBMS Interim Procedure

Inspections, Compliance, Enforcement, and Criminal Investigations

Design Quality. Indu Lakshman

Lessons from Pharmaceutical Laboratory related FDA Warning Letters

QUALITY POLICY MANUAL

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE 5/06/08

The Complete Guide to FDA Design Controls

QUALITY MANUAL. This document defines the requirements, processes, structure and documentation for the Teledyne DGO Quality Management System.

ISO General Requirements for Competence of Testing Laboratories Procedure

SKYCOAT, LLC QUALITY CONTROL MANUAL

Railroad Friction Products Corporation

SELLER QUALITY REQUIREMENTS QCS-001 PROCESSING SOURCES

Quality Manual. Manasota Optics, Inc & 1749 Northgate Boulevard Sarasota, FL Issue # 7 dated 05/10/2018

Guidance for Industry - Computerized Systems Used in Clinical Trials

ISO 9001: 2008 Engineering Design Construction Quality Management System Sample - Selected pages (not a complete plan)

Managing Validation. Paperless Recorders

PTC s Windchill Product Lifecycle Management (PLM) System Facilitates Part 11 / Annex 11 Compliance

Transcription:

ZOLL Number: 90E0004 Page 5 of 15 1. INTRODUCTION 1.1 Purpose 1.2 Scope The purpose of this document is to provide guidance regarding the identification of a quality record and the documentation practices required for their proper creation and maintenance. These procedures apply to all documents related to the training of personnel and / or the design, testing (clinical and non-clinical), quality control, quality assurance, production, tracking, storage, service and distribution of ZOLL, medical devices. These procedures explain the manner in which data and / or information is recorded, transcribed, reviewed, transmitted and archived by ZOLL, personnel. (See also 90A0001, ation.) 2. RESPONSIBILITIES 2.1 All ZOLL, personnel are responsible for recording and storing training, design, clinical research, quality control, quality assurance, manufacturing, component and device tracking, storage, service and distribution information, as it is generated, in accordance with this document. 2.2 Each employee is responsible for ensuring the quality records he/she produces are accurate and complete. 2.3 Each department manager is responsible for ensuring their subordinates are adequately trained in the proper completion and maintenance of quality records. Department managers are responsible for ensuring quality records are maintained in accordance with the Quality Records Matrix (see Appendix A). 2.4 Quality Assurance is responsible for assisting in the identification of document or electronic files that are required in order to demonstrate: (1) conformance to specified internal or external requirements and (2) the effective operation of the quality system. 3. APPLICABLE DOCUMENTS 21 CFR Part 11 Electronic Records and Electronic Signatures 21 CFR Part 803 Medical Device Reporting (MDR) 21 CFR Part 806 Medical Devices: Reports of Corrections and Removals 21 CFR Part 820 Quality System Regulation 93/42/EEC Council Directive Concerning Medical Devices Proprietary ZOLL

ZOLL Number: 90E0004 Page 6 of 15 MEDDEV 2.12/1 March 2012 - rev.7 Commission of the European Communities Guidelines on a Medical Device Vigilance System 90A0001 90A0023 90A0127 ation Change Requests and Change Orders Electronic Records Back-up and Archival 4. DEFINITIONS 4.1 Quality Record-- A document or electronic file that is maintained to demonstrate: (1) conformance to specified internal or external requirements and (2) the effective operation of the quality system. Quality Records can include databases relevant to the above. 4.2 s identified as Quality Records include the following and their specified subparts (see relevant SOPs): Management Reviews (CONFIDENTIAL) Quality System Record Corrective Action Requests Supplier Evaluations (CONFIDENTIAL) Inspection and Nonconformance Reports Dock to Stock List Audit Reports (CONFIDENTIAL) Design Review Records Design History Files (DHF) Device Master Records (DMR) Technical Files Device History Records (DHR) Purchase Orders Equipment Maintenance Records Calibration Records Material Review Board Records Approved Supplier Lists Employee Training Records Complaint Report Forms Functional Test Reports System Problem Reports Change Requests & Change Orders Medical Device Tracking Missing Data Log Proprietary ZOLL

ZOLL Number: 90E0004 Page 7 of 15 5. PROCEDURE 5.1 General 5.1.1 Record all information directly, promptly and legibly using permanent ink, preferably BLACK ink. (Do not use felt-tipped pens.) 5.1.2 All documentation must be dated with the date on which the entry was made. DO NOT BACK-DATE AN ENTRY. 5.1.3 Data should be recorded using clear concise language, initialed, then dated in such a manner as to avoid any doubt as to when or by whom the entry was made. 5.1.4 Data entry should be recorded by the individual performing the activity 5.1.4.1 If a signature or date was omitted and employee is available, the employee who performed the work should sign with the current date and record a reason for the omission including the date on which the work was performed. 5.1.4.2 If a signature or date was omitted and employee is unable or unavailable, the employee s Manager/Supervisor will have signature authority. Manager/Supervisor shall sign with the current date & structure Manager Name signing for Employee name. 5.2 Signatures on Quality Records: 5.2.1 Quality Records may be signed using either handwritten signatures or electronic signatures. All electronic signatures must be compliant to 21 CFR Part 11. 5.2.2 All signatures, both handwritten and electronic, are legally binding. Upon request, one may be required to provide additional testimony that a specific electronic signature is the legally binding equivalent of the signer s handwritten signature. 5.2.3 Repetitious entries in a column may be completed by entering the data on the first and last row of the column and drawing an arrow from the first row to the last. See Example 1. Proprietary ZOLL

ZOLL Number: 90E0004 Page 8 of 15 Example 1: 5.3 Time and Dates Example 2: 5.3.1 Record all times in standard 12 hour format, such as 1:00 pm 5.3.2 Dates should be recorded as month day year, unless otherwise specified by a written procedure, instruction, or regulation for a specific form or label. Any reasonably apparent format or structure is acceptable. See Example 2 for commonly used formats. 2-9-15, 02-09-15, 02-09-2015, 2/9/15, 02/09/15, February 9, 2015 5.3.3 To avoid confusion, communication intended for Europe should use the format Year Month Day only, unless otherwise mandated by regulation for completion of a specific form or label. 5.4 Responding to Requested Information 5.4.1 When filling out forms and other documents that request information, respond to all requests. Do not leave blank spaces. The following should be used: 5.4.2 If the request does not apply, enter N/A, Not Applicable, in the blank space. Proprietary ZOLL

ZOLL Number: 90E0004 Page 9 of 15 5.4.3 If the information requested is unavailable but may be obtained later, enter N/I, No Information, in the blank space 5.4.4 If the information requested is not known and not obtainable, enter UNK, Unknown, in the blank space 5.4.5 If the information requested is not obtained, or an activity is not carried out, enter N/D, Not Done, in the blank space. An explanation of why the data was not obtained should be noted. 5.4.6 Entire blank pages or the unused portion of a page can be marked diagonally with a line, reason for unused space and date and initials. 5.5 Error Correction: Example 3: 5.5.1 Any change to a quality record should include a justification for the change (if not readily apparent) then be initialed and dated. See Example 3 5.5.2 To correct an incorrect entry: Example 4: 5.5.2.1 Draw a single line through the incorrect entry. Clearly enter the correct information adjacent to the error then initial and date the corrected entry. See Example 4 Example 5: 5.5.2.2 DO NOT use a liquid correcting fluid (e.g., White-out). See Example 5 Proprietary ZOLL

ZOLL Number: 90E0004 Page 10 of 15 Example 6: 5.5.2.3 DO NOT obliterate the original entry by crossing through it more than once. See Example 6 Example 7: 5.5.2.4 DO NOT write over previously entered information. See Example 7. 5.5.3 To correct an incorrectly checked box: 5.5.3.1 Circle the correct box and the associated words, draw a line through the incorrectly checked box and the associated words, then initial and date the correction, See Example 8. 5.5.3.2 DO NOT individually circle the box or associated wording as seen in Examples 9. Proprietary ZOLL

ZOLL Number: 90E0004 Page 11 of 15 Example 8: Correct- Line out and circle associated words and box. Example 9: Incorrect- Individually lined out and circled words. 5.6 Alterations of Forms 5.6.1 Alterations of led Forms, Standard Operating Procedures, Test Methods must be justified, approved and documented according to 90A0023- Change Request and Change Orders. 5.7 Storage: (General) 5.7.1 Quality Records are stored at the ZOLL facility (121 Gamma Drive, Pittsburgh, PA 15238) in such a manner as to maintain accessibility and prevent deterioration by environmental influences and loss. Records may be stored off-site in secured, environmentally protected facilities in accordance with 90A0001 ation. Quality Records intended for offsite storage shall be boxed, clearly labeled, and stored in a designated area. Records stored off-site shall be readily retrievable for review and duplication by the FDA. 5.7.2 Where possible, paper files will be stored in metal file cabinets to prevent deterioration or loss. 5.7.3 Electronic records will be backed up on a regular basis, according to 90A0127- Electronic Records Back-up and Archival. Back-ups will be stored in a safe location, preferably off-site. Proprietary ZOLL

ZOLL Number: 90E0004 Page 12 of 15 5.7.4 Quality Records are available for review and duplication by ZOLL employees. 5.7.5 Outside auditors (e.g., employees of the Food and Drug Administration) may also receive copies of these documents, provided they are NOT marked CONFIDENTIAL. All requests should be processed through the Quality Assurance department and a complete record maintained of all duplication. 5.8 Record Location: 5.8.1 All Quality Records are typically maintained by the group responsible for the development of that record. Refer to the Quality Record Matrix (Appendix A) for the specific location of each record. 5.9 Length of Storage: 5.9.1 Quality Records shall be maintained for a minimum of 12 years from the date of record creation, with the exception of employee training records, which shall be maintained for 12 years from the date of termination of employment. Proprietary ZOLL

ZOLL Number: 90E0004 Page 13 of 15 Appendix A Quality Records Matrix This matrix is the key to identifying and locating Quality Records. It includes the Quality Record name, a description of the record, the method of indexing, file location, responsible group, minimum length of storage and the document s disposition upon expiration. Quality Record Description Method of index File location / responsibility Minimum length of storage Disposition Management Review Record Corporate Quality Council meeting minutes. Date QA Quality System Record Index of procedures required by 21 CFR 820, but not product specific. order Corrective Action Requests Records of all internal corrective action requests. order Supplier Corrective Action Requests Records of all external corrective action requests. order Supplier Quality & Inspection and Nonconformance Reports File of all inspection and nonconforming material reports. order Dock to Stock List List of parts qualifying for the Dock to Stock Program. Date Audit Reports Records of internal and audits. order Supplier Evaluations Records of external supplier audits and evaluations order Supplier Quality & Design Review Records Records and minutes of all design reviews. order Design History Files Compilation of records which describes the design history of a finished device. Index Proprietary ZOLL

ZOLL Number: 90E0004 Page 14 of 15 Quality Record Description Method of index File location / responsibility Minimum length of storage Disposition Device Master Record Compilation of records containing the procedures and specifications for a finished device. Index Mfg Eng & Technical File Compilation of product information required by the Medical Device Directive 93/42/EEC. Technical File Category Device History Record Compilation of records containing the production and service history of a finished device. Top level: Serial or lot # Lower level: order of Work Order Purchase Orders Copies of all purchase orders. Alphabetical by Vendor Name Procurement & Equip. Maintenance Records of all equipment maintenance. Equipment ID and in the equipment database Mfg Eng & Calibration Records Records of all equipment calibrations Equipment manufacturer, ID, and Calibration database Mfg Eng & Material Review Board Records Copies of all records of Material Review Board decisions. Order Approved Suppliers List List of all suppliers currently approved for use. Database / ERP System Procurement Employee Training Records General Employee and Job Specific Training Records. Alphabetical by employee name. ZOLL on-line training platform or designated functional trainers. 12 years from date of termination of employment Destroy Proprietary ZOLL

ZOLL Number: 90E0004 Page 15 of 15 Quality Record Description Method of index File location / responsibility Minimum length of storage Disposition Complaint Report Forms Records of all product complaints received from the field. Order* RA & Adverse Event Reports Records that are associated with an adverse event that occurred in the field. Order Grouped by Year *Complaint Report Forms associated with Adverse Events will be filed with the Adverse Events RA & System Problem Reports Records of all discrepancies detected primarily during design verification & validation. Order Change Orders Records of all changes made to approved documentation Order. Medical Device Tracking Missing Data Log Log listing the aware date of the missing data, the date(s) of the missing data, the description of the missing data, and the reason the data is missing and why data could not be collected. Order Proprietary ZOLL