*** Supercedes: BECO E and COM , , & ***

Similar documents
SOUTH CAROLINA ELECTRIC COOPERATIVES' PRIMARY UNDERGROUND POWER CABLE SPECIFICATION

3 MODIFICATIONS TO EXISTING STANDARDS

Clark Public Utilities

15 kv EPR Insulated, Jacketed, URD Cable

WESTERN UNDERGROUND COMMITTEE GUIDE 2.14 (2.14/01/0990)

PV Solar Wiring Solutions

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

SECTION MEDIUM-VOLTAGE CABLES PART 1 GENERAL

STANDARD SPECIFICATION FOR SIGNAL CABLE. A. This Specification provides for single and multi-conductor insulated and jacketed cable for


The Contractor shall furnish and install all shielded power cable suitable for use on this project.

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables.

STANDARD FOR EXTRUDED INSULATION POWER CABLES RATED ABOVE 46 THROUGH 345 KV. Approved by AMERICAN NATIONAL STANDARDS INSTITUTE.

PILC Replacement: Getting the Lead Out

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways.

MATERIAL STANDARD FOR CABLES AND WIRES

STANDARD FOR CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV

Serv. Low-Voltage Cable Insulated Conductors for Overhead and Underground Distribution

Standard of Practice - Campus Electrical Distribution System

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

HDPE Conduit Specification 2011

SPECIFICATION FOR 600 VOLT CONTROL AND POWER CABLE SPECIFICATION NO. 557

Engineering Data for Copper and Aluminum Conductor Electrical Cables

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

Heavy Wall Heat Shrinkable Tubing 5-7. Flame Retardant Heavy Wall Heat Shrinkable Tubing 8. Heat Shrinkable Ends Caps 9

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

NORMAS DE REFERENCIA AEIC CS 1: ASTM B

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

SECTION METAL-ENCLOSED BUS MEDIUM VOLTAGE

Purchase Now ANSI/ICEA S STANDARD FOR 600 VOLT SINGLE LAYER THERMOSET INSULATED UTILITY UNDERGROUND DISTRIBUTION CABLES

SSC Series. Cold Shrink Splice 2017 PRODUCT GUIDE. 15/25kV Class. 35kV Class

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Test Report No.: Page 2 of 35

10-SDMS-02 SPECIFICATIONS FOR BARE COPPER CONDUCTORS

SECTION INSULATED WIRE AND CABLE

SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW ARROW ROUTE, FONTANA CA

SECTION PARK NON-SEGREGATED BUS SPECIFICATION

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018

City of Jacksonville Beach

SPECIFICATION FOR FRLS POWER CABLES

SECTION A. ASTM B3 - Standard Specification for Soft or Annealed Copper Wire; 2013.

11-SDMS-01 REV. 03 ( )

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, TYPE LS3SWU (INCLUDING VARIATION LS3SWUS)

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated.

Tele-Fonika Cable Americas

QUALIFICATION UPDATE. Eric Rasmussen. Quality Cables Since 1854

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

NPS/002/023 Technical Specification for 132kV Power Cables.

System No. SP777 (FOR HORIZONTAL OR VERTICAL SEPARATIONS)

WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

SECTION WIRES AND CABLES

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11

Cables ELE E L CT E C R T R IC I C A A L L

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

CONSULTATIONS TECHNICAL GUIDELINE. HVDC extruded cable

System No. C-AJ-8048

Glossary Of Terms M-1

SECTION HEAT TRACING FOR PLUMBING PIPING

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE

Welding Accessories

SECTION HEAT TRACING FOR PLUMBING PIPING

SECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR

RAYCHEM NT-MIL TUBING Modified Chlorinated Polyolefin, Elastomeric, Flexible, Flame Retarded, Heat Shrinkable

Accelerated Aging Tests for MV Cables

Article-No. Type. All dimensions in mm. Subject to technical changes. Other dimensions, reel lengths or colours available on request.

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

Technical Specification for Low Voltage Aerial Bundled HDPE Insulated Cables

Cables for Railway Signalling Applications General Requirements

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

Mining Products. Jacketing and Insulating Tapes Trailing Cable Splice Kits High Voltage Splice and Termination Kits Cable Repair Tape Special Items

Mining Products Jacketing and Insulating Tapes Trailing Cable Splice Kits High Voltage Splice and Termination Kits Cable Repair Tape Special Items Fon

BURNDY. Accessories TABLE OF CONTENTS. Heavy Wall Heat Shrinkable End Cap... F-9. Introduction... F-2. Clear Heat Shrink Tubing...

26/35kV Copper XLPE Insulation Electric Cable

PRODUCT SELECTION LOCATOR

PO Box 1081 Monticello, MN Ph Fax

TS 804 CABLES TABLE OF CONTENTS TRAFFIC SIGNAL EQUIPMENT POLE WIRING DIAGRAM LOCATIONS WITH CENTRE MEDIANS

Technical Data. Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE

Una e mpre sa Vi akab l e GLOSSARY.

CAJ. Combos. C-AJ of 5. Through Penetrations Series. Concrete. 3Fire Protection Products

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)

Test Report No.: Page 2 of 34

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. TB/T Translated English of Chinese Standard: TB/T1484.

8.1.2 Under no circumstances shall a service entrance be left unmetered. Notify the Company if an unmetered service is encountered.

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

Wire and Cable Heat-shrink Tubing Non-shrink Tubing Braided Sleeving Screening Braids Moulded Parts Terminals and Splices Wire and Cable Markers

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

Shrink-Kon Thin Wall Heat Shrinkable Tubing

CONTENTS. B. System Design and Performance Requirements

WHAT MAKES ENCORE S XHHW-2 UNIQUE? Our SuperSlick Elite technology may be installed without additonal lubricant

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

6A V CVQ cable (C rank)

Prepared By: Engineering Staff Approved By: Jerome T. Schmitz

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN

Transcription:

7/27/09 Page 1 of 9 R5 *** Supercedes: BECO E2.9-27.4 and COM 1-0696, 2-0196, & 5-0385 *** 1.0 Scope #2 AWG to 1000 KCMIL CONCENTRIC NEUTRAL JACKETED CABLES RATED 5-35 kv These Specifications cover single conductor Tree Retardant Crosslinked Polyethylene Insulated (TRXLP) and Ethylene Propylene Rubber (EP Rubber or EPR) Insulated Concentric Neutral Jacketed Cables having either a standard or reduced overall diameter. These Cables shall be suitable for installation in underground ducts and direct burial in earth in wet and dry locations. The operating voltages and system BIL levels shall be as follows: Cable Voltage Rating System Voltage System BIL 5 kv 2.4/4.16 kv & below 65 kv 15 kv 8.0/13.8 kv & below 110 kv 25 kv (NSTAR South) 13.2/22.9 kv 150 kv 25 kv (NSTAR North) 13.8/24.0 kv 125 kv The general system category is in accordance with Table 4-4, Note C of ANSI ICEA S-94-649 (i.e., 100% level). 35 kv rated cable will be used at the 13.2/22.9 kv voltage level 2.0 General 2.1 The cable shall be manufactured and tested in accordance with the latest edition of the ANSI/ICEA Standard S-94-649 Standard for Concentric Neutral Cables Rated 5 through 46 kv and AEIC Specification CS-8 except as otherwise required by this material specification. 2.2 If a conflict occurs between any of the Standards, Specifications and Publications referenced herein, they shall supersede each other in the following order of priority, except that the referenced AEIC Specification shall take priority over ICEA/ANSI for the Materials Qualification Test. A. NSTAR Material Specification R5 B. ANSI/ICEA S-94-649 C. AEIC CS8

Page 2 of 9 2.0 General, cont d Conductors shall be in accordance with the following, as specified by the Purchase Order: Aluminum #1 AWG 1/0 AWG Solid Aluminum 4/0 AWG 1000 kcmil, Class B Compressed Stranded Aluminum Copper #2 AWG 4/0 AWG, Class B Compressed Stranded Bare Copper 250 kcmil - 1000 kcmil, Compact Round Stranded Bare Annealed Copper 3.0 Conductor Shield (Stress Control Layer) For cables having compact round conductors, the manufacturer may reduce the conductor shield thickness in accordance with the referenced ANSI/ICEA Standard, paragraph 3.2.1. 4.0 Insulation 4.1 Insulation materials shall be qualified by the manufacturer in accordance with AEIC CS8 and specifically approved by the Company. Cables shall have either TRXLP or EPR insulation as specified in the cable ordering specifications on the purchase order. Specific compound or formulation shall be subject to Company approval. AEIC Qualification Long Form Test Report shall be submitted for this approval. Compound supplier and formulation must also be provided and is not subject to change without Company authorization. 4.2 The insulation thickness and diameter over the insulation for #2 AWG, #1 AWG, 1/0 AWG, 4/0 AWG, 250 kcmil, 500 kcmil, 750 kcmil and 1000 kcmil 5kV - 35 kv standard diameter cables shall be in accordance with the referenced ANSI/ICEA Standard. The 133% level of insulation shall be furnished for #2 AWG & #1 AWG 15 kv cables and 4/0 AWG 5 kv cables while all other 5 kv 35kV cables shall have the 100% level of insulation.

Page 3 of 9 4.0 Insulation, cont d 4.3 The insulation thickness for 1000 kcmil copper standard diameter 15kV and 25 kv cables having the 100% level of insulation shall be in accordance with the referenced ANSI/ICEA Standard except that the diameter over the insulation for the 25kV cable shall be 1.605 minimum to 1.700 maximum. 4.4 The Minimum, Maximum and Nominal Insulation Thickness and diameter over the insulation for reduced diameter cables shall be in accordance with the following: Conductor Size/ Minimum Point Maximum Point Nominal Voltage Rating 350-700 kcmil, 15 kv** 0.155 0.195 0.165 350-700 kcmil, 25 kv** 0.230 0.275 0.240 Diameters over the Insulation for Reduced Diameter Cables Conductor-Voltage, Ins. Tk Minimum Maximum 350 kcmil cpt-15 kv, 0.165 Nom.** 0.965 1.050 500 kcmil cpt-15 kv, 0.165 Nom.** 1.070 1.155 700 kcmil cpt-15 kv, 0.165 Nom.** 1.235 1.325 350 kcmil cpt-25 kv, 0.240 Nom.** 1.110 1.195 500 kcmil cpt-25 kv, 0.240 Nom.** 1.235 1.325 700 kcmil cpt-25 kv, 0.240 Nom.** 1.385 1.480 ** Insulation and jacket thickness have been reduced to fit into existing conduit 5.0 Extruded Insulation Shield for 15kV to 35kV Cables 5.1 The Insulation Shield for 15 kv to 35 kv rated cables shall comply with the referenced ANSI/ICEA Standard except that the Thickness and Indent Requirements for all 250 kcmil 1000 kcmil copper conductor cables shall be as follows: (The Minimum Point Thickness does not apply to locations at metallic shield indents)

Page 4 of 9 5.0 Extruded Insulation Shield for 15kV to 35kV Cables cont d Minimum Point Maximum Point Maximum Indent 0.024 0.048 0.015 5.2 Metallic Shield grooves or indents on the outer surface of the insulation shield shall not appear on the outer surface of TRXLP cables and shall not exceed a depth of 0.003 on EPR cables. 6.0 Semi Conducting Fabric Tape Insulation Shield (5 kv Cables Only) 6.1 For 5 kv rated cables only, the insulation shield shall be a black semi conducting fabric tape that is conspicuously labeled semi conducting over its entire length. The tape shall be applied so that it can be removed without leaving traces of semi conducting material on the underlying insulation. The manufacturer shall not apply a semi conducting coating or paint to the surface of the underlying insulation. 6.2 The semi conducting tape insulation shall not protrude or indent inward toward the conductor from the outer surface of the insulation by more than 0.005 on EPR cables. 7.0 Marker Tape Cables having a reduced overall diameter shall have the Company Name and Year of Manufacture durably applied to a longitudinal, non-hydroscopic marker tape applied directly over the insulation shield. This marker tape may be applied to, but is not required for, cables having a standard overall diameter. 8.0 Concentric Neutral 8.1 The concentric neutral for #2 AWG copper and #1 AWG - 1000 kcmil aluminum cables shall consist of a serving of round annealed bare copper wires in accordance with the following table:

Page 5 of 9 8.0 Concentric Neutral- cont d Conductor Size & Concentric Neutral X-Section Concentric Wires Voltage Rating (Appx) Equivilent Number & Size 15 kv, #2 AWG Copper #2 AWG Cu 16 - #14 AWG 15 kv, #1 AWG Aluminum #4 AWG Cu 10 - #14 AWG #3 AWG Cu* 13 #14 AWG* 15 kv, 4/0 AWG Aluminum #3 AWG Cu 12 - #14 AWG 25 kv 1/0 AWG Aluminum #2 AWG Cu 16 - #14 AWG 24.66 kcmil Cu ** 6 - #14 AWG** 25 kv 500 kcmil Aluminum 1/0 AWG Cu 16 - #12 AWG 35 kv 1000 kcmil Aluminum 258.5 kcmil Cu 25 - #10 AWG * Acceptable Alternative **When specifically Specified 9.0 Jacket 8.2 The concentric neutral for 4/0 AWG - 1000 kcmil copper cables shall consist of flat annealed bare or tinned copper straps. The concentric neutral cross section area shall be equivalent to #2 AWG Copper for 4/0 AWG - 500 kcmil cables and 1/0 AWG copper for 700 kcmil - 1000 kcmil cables. 9.1 The jacket thickness for standard and reduced diameter cables, as measured over the round wires or flat straps shall be in accordance with the following, unless otherwise specified by the Company s Purchase Order. Conductor-Voltage Rating Overall Minimum Maximum Diameter Point Thickness Point Thickness 4/0 500 kcmil 5 kv Standard 0.040 0.075 #2-750 kcmil-15 kv Standard 0.045 0.080 1000 kcmil-15kv, 25 kv, & 35 kv Standard 0.070 0.120 350-700 kcmil-15 kv & 25kV** Reduced 0.025 0.050 ** Insulation and jacket thickness have been reduced to fit into existing conduit 9.2 Jackets over round wire concentric neutral wires for standard diameter cables shall be extruded to fill. The material shall be linear low-density polyethylene.

Page 6 of 9 9.3 Jackets over flat strap concentric neutral wires for standard diameter cables shall be sleeved and vacuum drawn to, as much as practical, fill the spaces between the flat straps. The portion of jacket material between the flat straps that is in contact with the insulation shield shall be free stripping. The material shall be linear low-density polyethylene. 9.4 Jacket material for low smoke cables (specified in the ordering specs on purchase order) shall be a black, non-halogen, flame retardant, thermoplastic, low smoke, low corrosive and low toxic compound. 9.5 Jackets for reduced diameter cables shall be extruded to overlay the underlying flat straps, without a separator tape over the flat straps. The material shall be a high temperature, high tensile strength, and abrasion resistant compound such as a polyethylene/polypropylene blend that has been specifically approved by the Company. 9.6 If the diameter over the insulation and/or concentric neutral of a particular length(s) of single conductor cable is such that the maximum diameter requirements of Section 11.0 of this Specification cannot be met, the manufacturer may seek specific approval from the Company to make appropriate adjustments in the jacket thickness of cables having either a standard or reduced overall diameter. 9.7 The outer surface of all jackets shall be ink indent printed (or approved equal) with the information required by Part 8 of the referenced ANSI/ICES Standard. Jackets for all #2 AWG copper, #1 AWG & 4/0 AWG aluminum conductor 15 kv cables and all aluminum conductor 25 kv - 35 kv cables shall have three equally spaced red stripes extruded along the length of the cable. These stripes shall be approximately 0.3 wide and 5 mil deep and shall not affect the jacket integrity. 9.8 The outer jacket surface of one single conductor cable on each parallel lay or triplexed reel put up and all single cable per reel put ups shall have ink indented (or approved equal) sequential footage markings. 9.9 The outer jacket surface of each single conductor cable of a parallel lay or triplexed reel put up shall be ink indent printed with 1 1 1, 2 2 2, and 3 3 3 respectively for phase identification. 9.10 The outer jacket surface of each cable on the reel shall be ink indent printed with the name NSTAR at 2 foot intervals. This requirement applies

Page 7 of 9 to all 15 & 25 kv, cables, 250 kcmil and larger and any other cables as may be specified on the purchase order. 9.11 The outer jacket of each cable on the reel of low smoke cables shall have 3 equally spaced yellow stripes for identification. 10.0 Maximum Cable Diameters To facilitate installation of three single conductor triplexed or paralleled cables in existing conduit, the maximum overall diameter of the single conductor cable shall not exceed the following: Conductor-Voltage, Ins. Tk Maximum Cable Diameter 4/0 AWG-5kV, 0.115 Nom 1.03 500 kcmil-5kv, 0.090 Nom. 1.21 #1 sol & #2 str AWG-15 kv, 0.220 Nom. 1.20 4/0 AWG 15 kv, 0.175 Nom. 1.21 1/0 AWG - 25 kv, 0.260 Nom. 1.29 500 kcmil str - 25kV, 0.260 Nom. 1.85 250 kcmil cpt - 15 kv, 0.175 Nom. 1.21 350 kcmil cpt - 15 kv, 0.165 Nom. ** 1.21 500 kcmil cpt - 15 kv, 0.175 Nom. 1.43 500 kcmil cpt - 15 kv, 0.165 Nom. ** 1.35 700 kcmil cpt - 15 kv, 0.165 Nom. ** 1.51 750 kcmil cpt - 15 kv 0.175 Mom. 1.63 350 kcmil cpt - 25 kv, 0.240 Nom. ** 1.39 500 kcmil cpt - 25 kv, 0.240 Nom. ** 1.51 700 kcmil cpt - 25 kv, 0.240 Nom. ** 1.66 1000 kcmil cpt 15kV, 0.175 Nom 1.89 1000 kcmil cpt -25 kv, 0.260 Nom. 2.06 1000 kcmil str 35 kv, 0.345 Nom. 2.45 ** Insulation and jacket thickness have been reduced to fit into existing conduit 11.0 Drawings Drawings shall be submitted for approval. Drawing details shall include reference to applicable NSTAR and industry specifications, NSTAR cat id, diameters of individual layers and overall diameter for triplexed assemblies. Conductor or shield wire Stranding compressed/compact and diameters.

Page 8 of 9 12.0 Factory Tests 12.1 The Manufacturer shall satisfactorily complete all tests required by this specification and all referenced industry Standards, Specifications and Publications. The 5 minute AC withstand production test for all cables and the partial discharge test for 15 kv 35 kv partial discharge free cables shall be performed in accordance with referenced ANSI/ICEA Standard. The test voltage levels shall be at the 133%voltage rating level for the #2 - #1 AWG conductor sizes and at the 100%voltage rating level for all 1/0-1000 kcmil cables (i.e., both standard diameter and reduced diameter ). 12.2 The 5 kv cables having a semi conducting fabric tape insulation shield shall be tested in accordance with the referenced ICEA/ANSI Standard and AEIC Specification except that maximum level of partial discharge shall be 5 Pico coulombs at 4.8 kv (2X the system voltage to ground) rather than the 200 volts/mil of nominal insulation thickness required for cables having an extruded insulation shield. 12.3 The manufacturer shall furnish a certified certificate of compliance stating that each shipping length has been tested in accordance with this specification and that the results of the tests comply with this specification and all applicable industry Standards, Specifications and Publications. The certificate of compliance shall include the information required by AEIC CS8 (except that gross tare and net weight may be omitted), the Company Stock Code and the starting and ending sequential footage marks for each reel. 12.4 The Manufacturer shall maintain a paper and/or electronic file of Certified Test Reports in accordance with the referenced AEIC Specification for a minimum of 7 years after the date of shipment. These Certified test reports shall be available to the Company upon request. 13.0 Packaging 13.1 All copper conductor cables shall be packaged with one cable per reel or three cables in a triplexed configuration, on steel reels unless otherwise specified. The reels shall have a maximum flange diameter of 84 inches and a maximum width of 57 inches. The maximum width shall include the arbor hub, bolts, and protruding ends. The trailing end of triplexed cables

Page 9 of 9 shall protrude through an opening in the drum rather an opening in the reel flange. The maximum weight of cable on the reel shall not exceed 16,000 lbs. 13.2 Aluminum conductor cables shall be packaged with one cable per reel or three cables in a parallel put up on wood reels unless otherwise specified. 13.3 The trailing end of all cables shall be tied to reel drum using double rope with two half-hitches spaced two feet apart. Duct tape shall be wrapped over the jacket in the area where the rope is to be applied to prevent slippage. The assembled half - hitches shall be covered with an additional wrapping of duct tape and a tie down rope should be covered by a protective sleeve until it is clear of the drum opening. Use 1/4 3 Ply Polypropylene Rope, Super Danline manufactured by Tubbs Cordage or approved equal. 13.4 All reels shall have a weatherproof tag or marking showing all information required by AEIC CS8, the Company cat id and the starting and ending sequential footage marks for reel of triplexed or parallel lay cable 14.0 Cable End Seals Cable ends shall be sealed with sealing mastic and heat shrink caps or approved equal to prevent the entry of moisture. 15.0 Exceptions If the manufacturer wishes to take exceptions to provisions of this specification or offer alternatives, his proposal shall clearly describe his exceptions and/or recommended alternates. 16.0 Delivery Shipping lengths and delivery location shall be specified on the Company s Purchase Order. Approved by: Amin Jessa Director, Distribution Engineering