Magner /35-3 Series Currency Counter. Operator's Manual

Similar documents
Rook Currency Counter

Moving money forward UV MG

Warning: This device complies with part 15 of the FCC Rules. Operation is subject to

Model S-2200 Single Pocket Currency Discriminator Operating Manual

Owner s Manual Currency Counter

S-1600 Series Currency Counter Operating Manual. Models S-1600, S-1615 and S-1625 Including "V" Series

S-1100 Series Currency Counter Operating Manual. Models S-1100, S-1115 and S-1125

UM Owner s Manual

S-1000 Mini Series Currency Counter Operating Manual. Models S-1000, S-1015 and S-1025

DMC When Accuracy Counts

1600 Currency counting machines

EB-300 / EB-310. Simple Counter with Detection. (Counting/Detecting) SERVICE MANUAL

July P Wide Format Stacker User Guide

Vertical Power Stacker

$250 Capacity ChangeMaker Operator s Manual

Table of contents. 1. Introduction

Collator Series 300/400 Operator Manual

Read Me First! DI380 OfficeRight DI425 FastPac Document Inserting Systems. Quick Reference Guide US/Canada English Version DI380 D425

Horizontal Belt Stacker

Océ DFS10. Operator Manual

64C Amplification Block. Instruction Manual

Instruction Manual HT 24 BM-D2400 Homogenizer

PROFESSIONAL PHOTO LAMINATOR OWNER'S MANUAL / PLEASE READ AND SAVE INSTRUCTIONS ROYAL SOVEREIGN INTL.INC.

2200-Lb. Semi-Electric Stacker OWNER S MANUAL

MAGNER START

nual k Excella E-1 Open Air Shaker N) manual New Brunswick Excella E-1 Open Air Shaker Operating manual

Relay 5000/6000/7000/8000

TF20 Tray Feeder. Instruction Manual. for JEDEC and IEC Standard Trays

Operational Manual. Spectrophotometer Model: SP-830 PLUS. Metertech Inc. Version 1.07

HOBO Plug Load Logger (UX ) Manual

High Precision Balances. Operation Manual

USER S OPERATING AND INSTRUCTION MANUAL

ISSUED: OCT. 11, 2005 REVISED: JAN. 1, 2007 HOSHIZAKI REFRIGERATED GLASS MERCHANDISER KD-90D MODEL INSTRUCTION MANUAL

SYSTEM 600 BILL CHANGER INSTALLATION INSTRUCTIONS Congratulations...

Xerox Nuvera Xerox Production Stacker Operator Manual

Manual Rotary Heat Sealers. Type: F108TX. List of content : Introduction 2. General description 3. Application 4. Safety precautions 5

Operating Instructions

Laboratory Refrigerator Model: ,-01,-02,-03,-04,-05,-06,-07,-08, -09,-10,-11,-12,-13,-14

Installation Manual. MONISAFE 400A System V ( ) Nautilus Hyosung, Inc. All Rights Reserved.

DJ Switch 10F V2 ORDERCODE 50365

CONTENTS. 3-1 Unpacking and Checking Installing Components Leveling the Scale... 1

INSTALLATION uline.com UNPACKING ASSEMBLY LEVELING H-1096, H-1097 H-1098, H-1099 DELUXE COUNTING SCALE

SYSTEM 600 GENERAL MAINTENANCE AND ADJUSTMENT GUIDE

Royal Sovereign RSL 2701 Laminator

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

electroplating DC power supply type SIFCO PROCESS POWER PACK 1028

BEFORE USING THE COUNTING SCALE

MA SERIES Owner's Manual

Service Manual For the E Ride 26

#201 Migun-Techno-World, 533 Yongsan-Dong, Yuseong-Gu, Daejeon-City, KOREA Tel: , 1688 Fax:

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation

Thank you for purchasing the SC-CONVERSION System 500/600 Conversion Kit. This Kit is available in two different versions:

WELCOME. Standard Change Makers, Inc. Changer Maintenance Overview General Maintenance Guide for Standard Change-Makers Machines

User Manual. XK315A1 water proof series Weighing Indicators. Applications: Electronic platform scale, weighing scale, etc.

Disc Mill, 12" Diameter STANDARD OPERATING PROCEDURE

Operation Manual. Dual Temperature Digital Dry Block Incubator. Catalog No. INCUBATOR Rev C. April 2016

CN Series P.N , Software rev. T 8, Revision A1- July 2014

LOW PROFILE FLOOR SCALE

Operators Manual IT IS THE RESPONSIBILITY OF THE OPERATOR TO MAINTAIN CUSTOMER SAFETY. Part No

BANKNOTE READER BT-11

VWR B-Series Balances Operation Manual

Installation- and Operating Instructions Interroll End stop RM 8811

Europe Bill Acceptor EBA xx

CSG A.L.C. COUNTING SCALE USER MANUAL

RENA XPS-3000 Base. User Guide. SC2000 Media Transport System

Operating Manual. Professional Weighing Equipment. TB Series intelligent weighing machine. Touch Color Screen HIGH RESOLUTION BALANCE

LASER GUIDED PARKING SYSTEM

Ceiling Camera Lift 2015

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

High Precision Balances

MiniCD. User Manual. American Weigh Scales. MCD-100 (100 x 0.01g MCD-500 (500 x 0.1g)

Mill, Burr STANDARD OPERATING PROCEDURE

Fun Industries Inc. G100D Grabber Deluxe Operation Instructions

Please read through the usage and service instructions outlined in this owner s manual before operating the unit. Warnings Diagrams...

Operator Manual. OHAUS Aviator 7000

This product has been tested and certified to conform to ASTM F2456, Youth Resistant Firearms Container.

ProColor Flat Panels. User Manual. 151 NE State Hwy 300, Ste A Belfair, WA

Solar Eye User Manual

Operational Manual for the HV-X Validator

MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

Instruction Manual ODY-1765

POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL

PK-110. User Manual. American Weigh Scales. PK-110 (0-44lb x 0.05lb / lb x 0.1lb)

HX-Series. HX-502 (500g x 0.01g) HX-3001 (3000g x 0.1g. Copyright 2014 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

Table Of Contents 1 Introduction Safety notes Description of machine Setting up the machine... 10

Mill, Disc, with Stone Plate STANDARD OPERATING PROCEDURE

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Best Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31)

78-RK VARIABLE SPEED HEAVY DUTY VIBRATOR OPERATING MANUAL

INSTALLATION INSTRUCTIONS

Introduction Specifications Control Panel / Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info / Warnings Warranty Information

Operators Manual. About This Product. Set-up, Operation, Maintenance, Parts catalog and Wiring Diagram GKC22-UCC

Gelovit 200 en English

user guide MACH 12 Coin Sorter and Counter Basic Control w/rs232 Interface

Offi ceright Folding Machine DF800/DF900

DESIGNERS AND BUILDERS OF CURRENCY CHANGERS AND ALLIED SYSTEMS SINCE 1921 FOR RLC-2 / RLC-3. Manual Part No Revision No.

J60 Lithium Ion UPS 350VA Model User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

i i i i i i i i i i i i i i i i i i i i i i i i i

HF2000 HF3000 HF2500 HF3500. Operator s Manual. Seaga Manufacturing, Inc. 700 Seaga Drive Freeport, IL USA

Transcription:

Magner 35-2003/35-3 Series Currency Counter Operator's Manual

Magner 35-2003 / 35-3 Series Introduction. The MAGNER 35-2003 / 35-3 is the most advanced Currency Counter available today. MAGNER's Design Engineer's have gathered input from experienced Currency Counter experts to develop a machine that is as compact as possible yet fast and extremely accurate. This instruction sheet for the MAGNER 35-2003 / 35-3 will provide the essential information to operate the MAGNER 35-2003 / 35-3 Currency Counter. Table of Contents Introduction. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 I. Safety Instructions. - - - - - - - - - - - - - - - - - - - - - - - - - - 2 II. Installation. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3 III. Parts Description. - - - - - - - - - - - - - - - - - - - - - - - - - - 4 IV. Function of Parts. - - - - - - - - - - - - - - - - - - - - - - - - - - 6 V. Operating Procedure - - - - - - - - - - - - - - - - - - - - - - - 11 VI. Troubleshooting - - - - - - - - - - - - - - - - - - - - - - - - - - 12 VII. Error Codes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13 VIII. Cleaning Jams Manually - - - - - - - - - - - - - - - - - - - - - 14 IX. Preventive Maintenance - - - - - - - - - - - - - - - - - - - - - 15 X. Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - 16 1

I. Safety Instructions. WARNING The currency counter automatically starts operating in certain circumstances. Consequently, it is important to always follow these precautions: 1. Do not wear loose clothing or jewelry while operating the currency counter. 2. Make sure that your hair does not touch the currency counter. 3. Do not touch currency that has been placed in the stacker while the motor is running. 4. Turn off the power before performing any maintenance or error corrections that require you to put your hands into the machine. 5. When replacing fuses, use only the same type and rating. A fire hazard can be created by using a higher rate fuse. 6. Do not operate the currency counter if it is wet. Also, do not touch the currency counter if you are wet. Operating the currency counter around water creates an electrical shock hazard, which might result in serious injury. CAUTION Keep drinks, food and other foreign objects away from the currency counter. Placing foreign objects on or into the currency counter can disable it. 2

Magner 35-2003 / 35-3 Series II. Installation. Unpacking After unpacking the currency counter, store the box and packing materials for future shipping. Failure to ship the currency counter in the original box and packing will void the warranty. Installation 1. Select an appropriate workspace. Make sure that the work surface is flat and level, away from bright sunlight, and as free of dust, dirt and smoke as possible. This will ensure proper operation and prevent damage to the rubber components of the machine. 2. Connect the power cord to the back of the currency counter. 3. Plug the cord into the wall outlet. WARNING Ensure that the outlet and the currency counter voltage settings match before performing step 2. If the settings are not correct, a fire hazard could be created or the machine could be damaged. If you have any questions about the power supply, do not connect it into the currency counter. 3

III. Parts Description. D + ACCM 0 CLR SP MAN. AUTO 1 2 3 4 5 6 7 8 9 0 START STOP Figure 1 : Sheet key D Size Detection Key (35-2003 only) SP Speed Selection Key MAN. AUTO Manual/Auto Start Key Numeric Keys START STOP Start/Stop Key 0 CLR Clear Key + ACCM Accumulation Key Density Key LCD Display (4-digit/Total Display + 3 digit/batch Display) Note Guides Hopper Sensor Sheet Key Hopper Count Sensor Stacker Sensor Note Jam Relese Lever Stacker Wheels Stacker Figure 2 : Front view 4

Magner 35-2003 / 35-3 Series Figure 3 : Count Sensor Figure 4 : Note Jam Release Lever Thickness Adjustment Dial Power Switch Fuse AC Input Receptacle Voltage Selection Switch Interface Connector (RS-232C / Option) or External Display Connector (Option) Figure 5 : Rear view 5

IV. Function of Parts. 1. Sheet Key and Function of each key D Size Detection Key (35-2003 only) This function is available with the mode 35-2003. - Press D key. "D" appearing on the display indicates that this function is on. - The counting speed is automatically set at SPEED - 2 when this function is in use. - Adjust the position of the Note Guides so that notes are centered in the hopper. When setting these Guides, allow enough clearance to enable the notes to move freely. - When a note of different length is detected, the machine stops and "ds1" appears on the display. Pressing of + ACCM key can include the note into 0 the batch. Pressing of CLR key can exclude the note from the batch. The remove the note from the staker. - To turn the size check Function (length) off, press D key again. NOTE Manufacturer recommend users to set the 5mm detection level. ( = setting value : 0.010 ) Figure 6 : Note Length 6

Magner 35-2003 / 35-3 Series SP Speed Selection Key - Three counting speeds are available on this machine: SP 1: Counts approximately 600 notes per minute. SP 2: Counts approximately 1,200 notes per minute. SP 3: Counts approximately 1,500 notes per minute. - To display the counting speed, press SP key. - To change the counting speed, press SP key again to the desired counting speed. Once a speed has been selected, the machine will always goes back to the selected setting until another change is made. MAN. AUTO Manual/Auto Start Key - This key sets the machine at either manual or auto start mode. - To turn the manual start mode on, press the MAN. AUTO key. "MAN" appearing on the display indicates that this function is on. The machine does not start automatically when notes are placed in the hopper. To start counting notes, press START STOP key. - To turn the manual start mode off, press the MAN. AUTO key. "MAN" on the display goes out. The machine starts counting automatically when the notes are placed in the hopper. Numeric Keys (Variable Batch Setting Keys) You can preset a desired number of notes, from o through 999, to be counted in a batch before the machine pauses, so that the operator can remove the notes. NOTE The factory default setting is 200. 7

8 To set a batch: - Touch the desired number using the numeric key. - A 3-digit display indicates the preset batch number. - The machine is now ready to count in the preset batch mode. To clear the current preset batch number and batch setting: - Press 0 key until the 3-digit display indicates "0". - Press the desired number again. START STOP Start/Stop Key - This key can be activated when the manual start mode is on. - The machine starts counting when this key is pressed. - The machine stops counting when this key is pressed during the counting. (The note count for the batch may be inaccurate.) 0 CLR Clear Key Press the key to clear the count figures on the display and reset errors. + ACCM Accumulation Key This function keeps a running total of the number of noes counted. - To start the running total function, press + ACCM key. "ACCM" appearing on the display indicates this function is on. IMPORTANT Any batch that has an error is not counted in total. Any batch count that is interrupted by an error must be counted again. To turn off this function, press + ACCM key again. The ACCM in the display will go out. When counting begins again, the display will start from zero. Density Key Five different density levels are available. Currency that is light or dark colored can be counted with fewer errors by changing the density settings. LEVEL 1: This is the most sensitive level to catch double notes that have a very similar level to single notes.

LEVEL 2: More sensitive than LEVEL 3 LEVEL 3: More sensitive than LEVEL 4 LEVEL 4: Default level from the factory LEVEL 5: The machine accepts any density of notes. When level 5 is in use, in the display will flash. The factory default setting is set at level 4. - To display the density level, press key once. - To change the density level, press key again to the desired density level. Once a density has been selected, the machine will always goes back to the selected setting until another change is made. LCD DISPLAY - 4-Digit Display: Counts and error messages are displayed. - 3-Digit Display: A preset batch number is displayed. Magner 35-2003 / 35-3 Series 2. Hopper The Hopper is capable of accommodating up to approximately 300 circulating bank notes. 3. Note Guides - When counting 5, 10 and 20EURO denominations, move the note guides to the middle. - When counting 50, 100, 200 and 500EURO denominations, move the note guides to the outside end. NOTE The note guide adjustment is more critical on the lower denomination. The 5 and 10EURO notes need to be centered on the hopper when counted. 4. Stacker and Stacker Wheels - The machine automatically stops after 200 notes are counted and stacked in the stacker. - In batch mode, the machine automatically resumes counting as soon as the previously batched notes are removed from the stacker. 9

- Two stacker wheels ensure neat stacking of notes at all times. 5. Note Jam Release Lever This lever is used to release the note(s) jammed inside the currency counter. 6. Thickness Adjustment Dial - This dial is used for adjusting the gap between the feeding and separating rollers so that only one note may pass through at a time. - For new(thinner) notes, adjust to a lower number: 4, 3, 2 and 1 - For used(thicker) notes, adjust to a higher number. 6, 7, 8 and 9 - Should error signals, dbl" or CH, occur frequently, turn the dial to the left to adjust the gap for proper thickness. 7. Power Switch - When the power switch is turned on, 8888" will appear on the display. The machine will stop automatically after the start-up sequence is performed. The display will show 0" which indicates the machine is ready for counting. - If a "Sensor Error Code" (see page 10) appears on the display instead of "0", take corrective actions in accordance with the instructions on page 12. - The Power Switch should be turned OFF if the machine is not used for an extended period of time. 8. Fuse Use only recommended fuse: 2A 9. AC Input Receptacle 10. Interface Connector (RS-232C/option or External Display/option) - As an optional part, the RS-232C interface is available to interface the currency counter with PC. - External display is also available as an optional part. 11. Voltage Selection Switch Please make sure that switch is set at the correct position for the available voltage. USA, Canada & Mexico : 120V European countries & others : 230V 10

Magner 35-2003 / 35-3 Series V. Operating Procedure For trouble-free operation, perform the following steps in the order given. 1. Prepare the currency A. Remove and discard clips, rubber bands and tags from the notes to be counted. B. Fan each group of notes before counting as shown in Figure6, and remove the following: - Torn, wet, oily or soiled notes - Notes of incorrect denomination - Any other foreign matter attached to, or inserted between the notes. C. Put the notes aside. Do not place them in the currency counter hopper until you set the desired functions. WARNING The currency counter runs momentarily when you first turn it on.figure 6 : Fanning the stack Figure 7 : Fanning the stack 2. Turn the power switch to ON A. Be sure that the machine does the following: - The motor turns the hopper and stacker wheels. - The display reads 8888 to test all of the display segments. - Each function key turns on in sequence to show that it is operational. B. When 0 appears on the LCD display, the currency counter is in the ready- 11

to-count mode. - If a Sensor Error Code (see page 10) appears on the display instead of 0, take corrective actions in accordance with the instructions on page 12. 3. Adjust the thickness adjustment Dial The thickness adjustment dial is set at 5 as the standard setting. - For new(thinner) notes, adjust to a lower number: 4, 3, 2 and 1 - For used(thicker) notes, adjust to a higher number. 6, 7, 8 and 9 WARNING Trial and error is recommended before you make the final adjustment. Small adjustment of 1/2 number or less works best. VI. Troubleshooting If you experience an operational error while using the currency counter, the following section will help you identify the problem and provide a possible corrective action. Should an error occur, a code will appear on the display Refer to the error code chart on page 11 to determine the cause of the error and its possible resolution. In some situations, a problem occurs in the actual operation of the machine without displaying an error code. If this happens, refer to the operation faults chart on page 11 to determine the corrective action. Figure 8 : Note Jam Release Lever Figure 9 : To lockup the Note Jam Release Lever. 12

Magner 35-2003 / 35-3 Series VII. Error Codes When an error occurs, the machine immediately stops and produces an electric beep while the display alternately flashes the error code and count figure. The note count for the batch in which the error occurred may be inaccurate. NOTE To ensure an accurate count, recount the last batch in the stacker after correcting the error and pressing 0 CLR key. Use tables on the following pages to find the error code, possible causes and corrective actions. 1. Sensor Error Codes Error Code HJ SJ Corrective Action Hopper sensor is blocked - Remove the note(s) from the hopper to restart. Stacker sensor is blocked - Remove the note(s) from the stacker to restart. JA Count sensor is detecting note(s) in the machine - Remove the note(s) to restart. FEEd Feed motor is not working. CSE Count sensor(both left and right) error - Clean the sensors to restart. CSE1 Count sensor(left) error - Clean the left side sensor to restart. CSE2 Count sensor(right) error - Clean the right side sensor to restart. 2. Counting Error Codes Error Code HF CH dbl SE SC Corrective Action Half note detected - Press <CLR> key to restart. Chained note detected - Press <CLR> key to restart. Double note detected - Press <CLR> key to restart. Skewed - Press <CLR> key to restart. Short count when batching. When the notes on the hopper were not enough to reach the desired number. SF Stacker is full(notes in the stacker reach 200 pieces) - Remove the notes from the stacker. 13

3. Operation Fault Fault Currency counter does not power up when machine is turned on. Self-test failure. Electrical burn orders. Loud buzzing slapping or other unusual noises during the operation. Corrective Actions: 1. Make sure that the currency counter is plugged into a wall outlet and that the power cord is plugged into the back of the machine. 2. Check that the voltage selection switch matches power input. Call for service. Turn off and unplug the currency counter. Call for service. CAUTION DO NOT insert tools into the currency counter. Doing so many damage the machine. DO NOT use oil on any part of the currency counter. Oil on sensors or internal mechanisms can prevent correct operation. IMPORTANT If the corrective actions suggested here do not solve the problem, call your service representative. VIII. Cleaning Jams Manually 14 - Record the running and grand totals. - Turn the power switch off. NOTE Turning off the currency counter clears the memory of totals. - Remove all notes from the hopper and stacker. Also, remove notes from inside the currency counter by using the Note jam release lever. - Push the Note jam release lever all the way up. - If it is necessary to keep locking up the Note jam release lever to release jam note(s), insert a coin into the slot. - Make sure that the Note jam release lever is returned to the original position after jam note(s) is cleared.

Magner 35-2003 / 35-3 Series IX. Preventive Maintenance Preventive maintenance, requiring partial disassembly by service technicians, is recommended every 180 days. With heavy usage(more than one shift per day, continuous service, etc.), this service will be needed more often. To make sure the operation is as trouble-free as possible, perform the following steps: <Daily> Perform the following steps on a daily basis: 1. Turn off the currency counter when not in use. 2. Use the protective cover(dust cover) when the currency counter is not in use. 3. With a clean, lint-free, dry cloth, dust hopper and stacker areas. <Weekly> Perform the following steps on a weekly basis: 1. Turn off the currency counter and disconnect the power source. 2. Use a vacuum, lint-free cloth or dry air to remove dust from the bill passages and sensors. <Sensor Locations> 1. Count Sensors 2. Hopper Sensors 3. Stacker Sensors See Figure 2 ~ 4 Page 4 and 5 15

X. Specifications Counting Speed: Display Type: Document Size Limits: Approximately 600 / 1200 / 1500 notes per minute LCD: 4-digit total display / 3-digit batch display 110x185 ~ 50x85 (mm) 4.33x7.28 ~ 1.97x3.35(inches) Input Hopper Capacity: Approximately 300 circulated notes Output Stacker Capacity: Approximately 200 circulated notes Batching: variable 1 to 999 (maximum) Error Detection: Double/Chain/Half-note/Jam Document Feed Mechanism: Friction, intermittent roller type Overall Dimensions: 255(H)x280(W)x245(D) mm 10.04(H)x11.02(W) x9.69(d) inches Net Wight: 5.5Kgs./12.1Lbs. Power Source: AC120V±10%, 60/50HZ / AC230V±10%, 60/50HZ Power Consumption: 40W Temperature Limits: Operating: 0ºC ~ 40ºC / 32ºF ~ 104ºF Storage: -30ºC ~ 85ºC / -22ºF ~ 185ºF Density Setting: Adjustable 5 levels Accessories: Power Code NOTE Specifications and design are subject to change without prior notice. 16

Magner 35-2003 / 35-3 Series 17