Introduction. Railway Cables

Similar documents
Construction guideline

RT/ZHLS, A-2Y(L)2Y External Telephone Cables to NR/PS/TEL/00015

CABLEMASTER CABLE GUIDE

DATA NETWORK TECHNOLOGY

Data sheet chainflex CFSPECIAL.182

Content HYBRID AND SPECIAL CABLES G 2 NEW NEW NEW NEW. page. Applications... G/3. Construction examples of special cables

Halogen-free data transmission cable with colour code acc. to DIN resistant to a wide range of chemical media

Comparison of BS 5308, PAS 5308 and BS EN

H-FLEX CABLES 10/2017

Caledonian Cables Ltd

Data sheet chainflex CF887


MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

The Company by Peter Bröckskes sen. an independent, middle sized company

Content. Festoon 715 P PUR cable for flexible application in festoon systems... G/21

Article number: Sheath marking ACE - TKF LTC-S RP 24x SM G.657.A1 6x4 A-DQ(ZN)B2Y {Batch} {Year} {Length}

Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath

AMWAJ TELECOMMUNICATION FACTORY


FieldLink for PROFIBUS Applications

Cables de Comunicaciones Zaragoza. CW1601 Approval application.

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

Armoured Instrumentation Cables to BS7917

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Highly flexible control cable with PVC core insulation and PVC sheath - certified for North America

PURENET-U (Part No.: U RXX2, U PXX2)

HELUKABEL CC-Link Certified Cables

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE

INSTRUMENTATION, CONTROL AND THERMOCOUPLE CABLES

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

CONSULTATIONS TECHNICAL GUIDELINE. HVDC extruded cable

SPECIFICATION FOR FRLS POWER CABLES


TECHNICAL SPECIFICATION

Content. PV1-F Halogen-free cable for photo-voltaic systems... G/11. PV1-F dual Halogen-free twin cable for photo-voltaic systems...

RG-59, RG-59+2DC, UTP CAT6, SFTP CAT6

Separator, suitable tape between the braid and outer sheath

IP68 Quick connection system. IP68 Quick connection system

Instrumentation and Thermocouple Cables

Instrumentation and Thermocouple Cables

Electric cables. CRANES APPENDIX

EHV XLPE CABLES CDCC LINE

Coaxial Cables for Broadband Communication Networks European Edition

HELUKABEL CC-Link Certified Cables

M-FLEX CONTROL CABLES

CONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

Instrumentation Cables

loop 0.60 mh/km 0.65 mh/km RCCY031/032 /KS1 RCCY031/032 /NS mh/km 0.70 mh/km RCCY033/034 /KS1 RCCY033/034 /NS1

Application (easy to strip) ES cable for permanent installation. and mechanical stress (easy to strip) 1x2x22AWG 1


Type 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn

Fibre optic cables CTC LSZH 1,2kN

MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP - Instrumentation cables)

INTERNATIONAL STANDARD

INDUSTRY. Welding Cables. Highly flexible, resistant and robust.

Photo: HELUKABEL. Robotic Cables H 1

138-1: 2015 CEB SPECIFICATION. AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 )

Available in 0.75 to 16.0 sq mm. Red, Yellow, Blue, Black, White, Gray and Green (for earthing) Specification IS 694:1990

MATERIAL STANDARD FOR CABLES AND WIRES

BUS CABLES. Content. IBL 600 PVC Interbus-Loop cable... E/11. S IBL 605 PUR Interbus-Loop cable for cable tracks... E/11

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

Compact Module. Enhanced Category 5 FTP Cabling System

XLPE MATERIAL NATIONAL CABLES INDUSTRY XLPE INSULATED MEDIUM VOLTAGE CABLES

Copper Cable Company Limited

Cable solutions for Automation & Drives

SUBMERSIBLE. Electric cables

Product overview. Product characteristics. Article number Cables - Universal Print Date

WIND TURBINES DEDICATED CABLES LV AND MV VOLTAGE RUBBER CABLES

catalog Copper Wires

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

according to UL AWM 758, Style and based on EN resp. VDE

New designed XLPE-insulated cables substituting paper-insulated pipe type cables

Engineering Data for Copper and Aluminum Conductor Electrical Cables

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

Cable solutions for Automation & Drives

YKY, YKY-żo 0,6/1kV PN-93/E-90401, PN-HD-603 S1, IEC

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE

137-1: 2015 CEB SPECIFICATION. XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE

Power Systems 2 ELE3015. Lecture 1: Transmission Lines

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, TYPE LSC5FS (INCLUDING VARIATIONS LSC5FSW, LSC5OS, AND LSC5OSW)

THE PATHWAY TO POWER HIGH AND EXTRA HIGH VOLTAGE CABLES

PRODUCT INFORMATION ÖLFLEX CRANE. Info Suitable for outdoor use Integrated supporting element Also suitable for power chains and cable trolley systems

List Price w.e.f. 24th July, 2018

List Price w.e.f. 02nd January, 2018

Cables for Railway Signalling Applications General Requirements

PHOTOVOLTAIC CABLES. Energy and Fiber Optical Cables for Solar Energy Systems.

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE

Rail Wire Guide. Harnessing and Electro-Mechanical Solutions for Demanding, Harsh Environment Applications... LFH FREE

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category.

Cable solutions for Automation & Drives

Wires & Cables for Space Applications

Fiber Optic Cables. General cable specification

Single core conductor BETAtherm 145

Cable solutions for Automation & Drives

CREATE NETWORKS. project business by LAPP

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

Electrical Insulating Tapes

Transcription:

Railway Cables

Introduction Railway Cables Plant Kapfenberg-Einöd Pengg Kabel GmbH is an Austrian cable manufacturer and a member of the german Wilms group with two plants in Styria. We have two sites, one in Kapfenberg where we produce copper cables and the second in Wartberg where we are specialised on fiber optic cables and components. At the location in Kapfenberg-Einöd we have been producing railway cables for more than 40 years. In order to ensure the quality of our products and services and to improve continuously the processes, we have already in the midnineties set up a quality management system according to EN ISO 9001 which is certified by an accredited body. With our production equipment we are able to produce all usual kinds of stranding such as layer-stranding, SZ-stranding and random stranding. On this basis, we are able to produce the main types of railway and telecommunication cables. Telecommunication cables: conductor diameter 0,4 mm up to 1,8 mm symmetric local and district cables symmetric indoor cables all types of jumper wires according to national and international standards and/or customers specifications. Differential protection cables: conductor diameter 0,4 mm and 1,8 mm Cables for watersupply- as well as for power-supply companies: with pairs, triples or quads special filling materials different kinds of electrical shielding Control cables for railway applications, special cables: with plastic insulation with cores, pairs or quads spare cables in plastic version for paper-lead cables Flexibility and customer proximity are the bases for a successful development on the market. New developments and product improvements are always necessary. Apart of the permanent search for improvements of our products, our efforts for the future run towards reduction of production time, increase of flexibility and constant improvement of quality, in order to be a reliable partner for our customers. Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 3

Contact Persons Railway Cables Managing Director: Sales Director: Max Rothwangl Managing Director (+43) (0)3862 23990 410 (+43) (0)3862 23990 452 @ max.rothwangl@penggkabel.at Product Development Manager: Werner Lenger Product Development Manager - Railway Cables (+43) (0)3862 23990 418 (+43) (0)3862 23990 444 @ werner.lenger@penggkabel.at Uwe Löcker Key Account Manager (B, BG, BY, CH, CY, DK, E, EST, FIN, GR, H, I, IRL, L, LT, LV, N, P, RO, S) (+43) (0)3862 23990 690 (+43) (0)3862 23990 672 @ uwe.loecker@penggkabel.at Area representatives: PROCABLE S.A. Isabelle & Udo Guldner Area representative in France and Luxembourg 7, Z.I. Bombicht L-6947 Niederanven Luxembourg Interteam Srl Mauro Rota Area representative in Italy Via C. Battisti, 50 I-24019 Zogno (BG) Italy Cableteam FZE Stefan Leicht Area representative in UAE HQ Building A109/1 Silicon Oasis, Dubai UAE +352 (0)263 40244 +352 (0)263 40245 @ procable@pt.lu URL: www.procable.lu +39 0345 90938 +39 0345 50684 @ rota.mauro@inter-team.it URL: www.inter-team.it +971 (0)503508277 +971 (4)4434698 @ swl501@gmail.com Key Accounts: Robert Hofreiter Key Account Manager (A, AL, BIH, HR, KOS, MK, MNE, SLO, SRB) (+43) (0)3862 23990 683 (+43) (0)3862 23990 672 @ robert.hofreiter@penggkabel.at Holger Quest Key Account Manager (D) (+49) (0)172 95 99 471 (+43) (0)3862 23990 672 @ holger.quest@penggkabel.at Gerd Pichler Key Account Manager (I, NL, D) (+43) (0)3862 23990 441 (+43) (0)3862 23990 672 @ gerd.pichler@penggkabel.at Sasta/Sakelliou Spyros & CO OE Spyros Sakelliou Area representative in Greece 15B, Konstantinidou Str. GR-104 45 K.Patissia, Athen Greece CYNERPRO NV/SA Guy Colman Area representative in Belgium Laagstraat 65 B-9140 Temse Belgium Dr. Giorgio Cumbat Area representative in Italy Am Flecken 24 D-96450 Coburg Germany +30 (0)210 8322611612 +30 (0)210 8325444 @ sasta@otenet.gr +32 (0)32532350 +32 (0)32532351 @ guy.colman@cynerpro.be URL: www.cynerpro.be +49 (0)956128518 +49 (0)1728141232 @ giorgio.cumbat@ t-online.de 4 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Index Austrian Railways (ÖBB) from page 7 German Railways (DB) from page 17 French Railways (SNCF) from page 57 Swiss Railways (SBB) from page 65 Hungarian Railways (MAV) from page 69 Slovenian Railways (SZ) from page 73 Fiber Optic Cables from page 75 General Information from page 97 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 5

Railway Cables Note 6 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Austrian Railways, ÖBB S-X2YA2YB2Y 1x4x1,53 HD page 8 S-X2YA2YB11Y 1x4x1,8 K35 page 9 S-2Y2YBY..x4x.. page 10 S-2Y2YCB2Y..x4x.. (J0...) HD page 11 Austrian Railways (ÖBB) S-2Y2YCB2Y..x.. RE (J0...) HD page 12 S-2Y2YBY..x.. RE page 13 S-2YY..x.. page 14 F-2Y2YC2Y..x2x0,8 page 15 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 7

Austrian Railways PE insulated, star-quad, with inductive protection S-X2YA2YB2Y 1x4x1,53 HD C42 mutual capacity 2 number of double cores 1,53 dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km S-X2YA2YB2Y 1x4x1,53 HD 2 15,0 292,8 The cable is designed for the connection of ETCS-Balisen. Conductor: Insulation: Colour code: Cable make up: Screening: Sheath: Armouring: Protective cover: Cable short mark: solid, bare copper wire 1,53 mm PE (2Y) a core : transparent b core : transparent c core : RD d core : RD cores twisted to a quad, wrapping with tape copper wire netting, tinned (9x0,10mm); aluminium shield (A) PE, black (2Y) one layer steel tape (B) HDPE, grey (2Y) special design (X) protective PE cover with high density (HD) type - LEU - SIGNAL (4 x) - PENGG KABEL - <meter> - order number Technical Details (at 20 C) Standard: Customer information Conductor diameter: 1,53 mm Loop resistance: 19,8 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 42 nf/km Attenuation: 1,8 MHz 1,0 db/100m Impedance: 1,8 MHz 120+/-20 Ω Capacitance unbalance: K 1 400 pf/km e a1/2 650 pf/km conductor/conductor 2000 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Temperature range: during operation -30 to +60 C during installation -20 to +50 C 8 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Austrian Railways PE insulated, star-quad, with inductive protection S-X2YA2YB11Y 1x4x1,8 K35 C45 mutual capacity 2 # 1,83² dimension of conductor number of double cores filling Austrian Railways (ÖBB) cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km S-X2YA2YB11Y 1x4x1,8 (0,35) K35 2 19,9 450,4 The cable is designed for the connection of ETCS-Balisen. Conductor: Insulation: Colour code: Cable make up: Screening: Sheath: Armouring: Protective cover: Cable short mark: strand, bare copper wire 1,83 mm² PE (2Y) a core : transparent b core : transparent c core : RD d core : RD cores twisted to a quad, wrapping with tape copper wire netting, tinned (11x0,10 mm); aluminium shield (A) PE, black (2Y) one layer steel tape (B) Polyurethan Elastollan, black (11Y) special design (X) operation termperatur till -35 C (K35) type - LEU - SIGNAL (4 x) - PENGG KABEL - <meter> - order number Technical Details (at 20 C) Standard: Customer information Conductor cross section: 1,83 mm² Loop resistance: 19,8 Ω/km Insulation resistance: 1 GΩkm Mutual capacitance (at f=800hz): 42 nf/km Attenuation: 1,8 MHz 1,0 db/100m Impedance: 1,8 MHz 120+/-20 Ω Capacitance unbalance: k 1 400 pf/km e a1/2 650 pf/km conductor/conductor 2000 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Temperature range: during operation -35 to +60 C during installation -20 to +50 C Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 9

Austrian Railways PE insulated, star-quads, with rodent protection S-2Y2YBY..x4x.. C42 mutual capacity 2-100 number of double cores 0,8 0,9 1,4 dimension of conductor filling cable elements overall shield, armouring conductor diameter 0.8 mm conductor diameter 0.9 mm conductor diameter 1.4 mm Type number of outer diameter weight outer diameter weight outer diameter weight double cores approx. mm approx. kg/km approx. mm approx. kg/km approx. mm approx. kg/km S-2Y2YBY 1x4x... 2 11,6 186,7 12,3 208,2 15,5 236,6 S-2Y2YBY 2x4x... 4 15,6 303,0 17,8 363,3 23,4 612,8 S-2Y2YBY 3x4x... 6 16,3 326,0 18,7 392,7 24,6 721,4 S-2Y2YBY 5x4x... 10 18,7 432,4 20,5 511,1 29,2 977,2 S-2Y2YBY 7x4x... 14 20,0 503,8 22,0 600,4 31,6 1181,6 S-2Y2YBY 10x4x... 20 25,2 714,4 28,0 822,7 40,5 1684,7 S-2Y2YBY 15x4x... 30 28,5 932,2 31,6 1125,0 47,1 2371,1 S-2Y2YBY 20x4x... 40 29,8 1040,1 33,1 1326,3 49,4 2843,9 S-2Y2YBY 25x4x... 50 35,4 1379,2 39,9 1706,8 60,0 3770,0 The cable is desigend for use in railway protection systems. Conductor: solid, bare copper wire 0,8 / 0,9 / 1,4 mm Insulation: PE (2Y) Colour code: beginning quad other quads a core: BK transparent b core: RD RD c core: GN GN d core: BU BU Cable make up: cores twisted to quads, quads stranded together in concentric layers, wrapping with tape Sheath: PE, black (2Y) Armouring: one or two layers steel tape (B), wrapping of tape Protective cover: PCV, grey (2Y) PENGG KABEL - type- ÖBB sign - <meter> ; SIGNAL fills the free space for gaps, less then 10 cm Technical Details (at 20 C) Standard: ÖVE- K 11 / 4 06.95 Conductor diameter: 0,8 0,9 1,4 mm Loop resistance: 72,3 56,6 23,4 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 100% 42 nf/km 95% 40 nf/km 75% 38 nf/km Capacitance unbalance: K 1 100% 800 - - pf/300m 95% 400 - - pf/300m K 9-12 300 - - pf/300m e a1/2 650 - - pf/300m K 1 100% - 185 185 pf/425m ( 6 quads) - 70 70 pf/425m K 9-12 - 170 170 pf/425m e a1/2-550 550 pf/425m conductor/conductor 2500 V/50Hz/2min conductor/shield 2500 V/50Hz/2min Operating voltage: 250 Veff Temperature range: during operation -30 to +60 C during installation -20 to +50 C 10 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Austrian Railways PE insulated, star-quad, with inductive protection S-2Y2YCB2Y x4x (J ) HD C42 0.9 mutual capacity 1.4 dimension of conductor 2-100 number of double cores filling Austrian Railways (ÖBB) cable elements overall shield, armouring conductor diameter 0.9 mm conductor diameter 1.4. mm Type number of outer diameter weight outer diameter weight double cores approx. mm approx. kg/km approx. mm approx. kg/km S-2Y2YCB2Y 1x4x... 2 16,1 441 19,3 629 S-2Y2YCB2Y 2x4x... 4 22,0 670 27,2 1012 S-2Y2YCB2Y 3x4x... 6 21,5 711 28,8 1141 S-2Y2YCB2Y 5x4x... 10 25,5 946 33,0 1455 S-2Y2YCB2Y 7x4x... 14 27,0 1026 36,0 1743 S-2Y2YCB2Y 10x4x... 20 32,2 1349 46,5 2869 S-2Y2YCB2Y 15x4x... 30 36,2 1659 52,3 3611 S-2Y2YCB2Y 20x4x... 40 37,5 1918 54,4 4149 S-2Y2YCB2Y 25x4x... 50 44,9 2459 65,2 5007 The cable is desigend for use in railway protection systems. Conductor: solid, bare copper wire 0,9 / 1,4 mm Insulation: PE (2Y) Colour code: beginning quad other quads a core: BK transparent b core: RD RD c core: GN GN d core: BU BU Cable make up: cores twisted to quads, quads stranded together in concentric layers, wrapping with tape Sheath: PE, black (2Y) Screening: one layer copper wire 0,8 mm (C), wrapping of tape Armouring: two layers steel tape (B), wrapping of tape Protective cover: HDPE, grey (2Y) Cable short mark: caracteristic number of reduction factor: (J0,65) protective PE cover with high density (HD) PENGG KABEL - type- ÖBB sign - <meter> ; SIGNAL fills the free space for gaps, less then 10 cm Technical Details (at 20 C) Standard: ÖVE- K 11 / 4 06.95 Conductor diameter: 0,9 1,4 mm Loop resistance: 56,6 23,4 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 100% 42 nf/km 95% 40 nf/km 75% 38 nf/km Capacitance unbalance: K 1 100% 185 185 pf/425m ( 6 quads) 70 70 pf/425m K 9-12 170 170 pf/425m e a1/2 550 550 pf/425m conductor/conductor 2500 2500 V/50Hz/2min conductor/shield 2500 2500 V/50Hz/2min Operating voltage: 250 250 Veff Temperature range: during operation -30 to +60 C during installation -20 to +50 C Reduction factor: according to ÖVE-K11/ 4. 6.95 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 11

Austrian Railways PE insulated, single core, with inductive protection S-2Y2YCB2Y..x.. RE (J ) HD mutual capacity 5-80 number of cores # 1,5² # 2,5² # 4,0² dimension of conductor filling cable elements overall shield, armouring cross section 1,5 mm² cross section 2,5 mm² cross section 4mm² Type number of outer diameter weight outer diameter weight outer diameter weight cores approx. mm approx. kg/km approx. mm approx. kg/km approx. mm approx. kg/km S-2Y2YCBY 5x... 5 17,7 576 19,3 679 21,6 770 S-2Y2YCBY 10x... 10 21,0 745 24,2 978 24,3 1190 S-2Y2YCBY 15x... 15 23,6 929 26,5 1195 30,2 1572 S-2Y2YCBY 20x... 20 25,2 1067 28,4 1406 32,7 1827 S-2Y2YCBY 30x... 30 28,1 1339 32,1 1804 37,6 2445 S-2Y2YCBY 60x... 60 35,8 2144 42,2 3429 50,3 4889 S-2Y2YCBY 80x... 80 40,5 3028 48,1 4286 57,4 6219 The cable is designed for use in railway protection systems, for underground laying and drawing into conduits. The cross section of this cable type goes from 0,75 to 25 mm². Conductor: Insulation: Colour code: Cable make up: Sheath: Screening: Armouring: Protective cover: solid, bare copper wire PE (2Y) tracer core in each layer: blue other cores: transparent cores cabeld together in concentric layers, wrapping of tape PE, black (2Y) one layer copper wire 0,8 mm (C), wrapping of tape two layers steel tape (B), wrapping of tape HDPE, grey (2Y) Technical Details (at 20 C) Standard: ÖVE- K 10 / 10 06.95 Conductor cross section: 1,5 2,5 4,0 mm² Conductor resistance: 12,1 7,28 4,56 Ω/km Insulation resistance: 5 GΩkm Mutual capacitance: 120 120 120 nf/km conductor/conductor 3500 3500 3500 V/50Hz/2min conductor/shield 3500 3500 3500 V/50Hz/2min Operating voltage: 800 800 800 Veff Temperature range: during operation -30 to +60 C during installation -5 to +50 C Reduction factor: according to ÖVE-K10/10 06.95 Cable short mark: circular (R) single core (E) caracteristic number of redution factor: (J0,65) protective PE cover with high density (HD) PENGG KABEL - type- ÖBB sign - <meter> ; SIGNAL fills the free space for gaps, less then 10 cm 12 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Austrian Railways PE insulated, star-quad, with inductive protection S-2Y2YBY..x.. RE # 0,75² mutual capacity # 1,5² # 2,5² dimension of conductor 5-100 number of cores filling Austrian Railways (ÖBB) cable elements overall shield, armouring cross section 0.75 mm² cross section 1,5 mm² cross section 2.5 mm² Type number of outer diameter weight outer diameter weight outer diameter weight cores approx. mm approx. kg/km approx. mm approx. kg/km approx. mm approx. kg/km S-2Y2YBY 5x... 5 12,5 228 14,1 293 15,5 373 S-2Y2YBY 10x... 10 15,0 316 17,4 434 19,6 592 S-2Y2YBY 15x... 15 16,4 392 19,2 562 21,9 767 S-2Y2YBY 20x... 20 17,4 463 20,8 684 24,6 996 S-2Y2YBY 30x... 30 19,8 596 23,7 895 28,3 1341 S-2Y2YBY 60x... 60 25,6 1024 31,2 1605 37,2 2403 S-2Y2YBY 80x... 80 28,8 1281 35,7 2086 42,1 3076 S-2Y2YBY 100x... 100 32,0 1532 40,0 2530 48,2 3858 The cable is designed for use in railway protection systems, for underground laying and drawing into conduits. The cross section of this cable type goes from 0,75 to 25 mm². Conductor: Insulation: Colour code: Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire PE (2Y) tracer core in each layer: blue other cores: transparent cores cabeld together in concentric layers, wrapping of tape PE, black (2Y) one layer steel tape (B) PVC, grey (Y) Technical Details (at 20 C) Standard: ÖVE- K 10 / 10 06.95 Conductor cross section: 0,75 1,5 2,5 mm² Conductor resistance: 24,5 12,1 7,28 Ω/km Insulation resistance: 5 GΩkm Mutual capacitance: 100 120 120 nf/km conductor/conductor 2500 3500 3500 V/50Hz/2min conductor/shield 2500 3500 3500 V/50Hz/2min Operating voltage: 400 800 800 Veff Temperature range: during operation -30 to +60 C during installation -5 to +50 C Cable short mark: circular (R) single core (E) PENGG KABEL - type- ÖBB sign - <meter> ; SIGNAL fills the free space for gaps, less then 10 cm Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 13

Austrian Railways PE insulated, single core S-2YY..x.. mutual capacity 5-100 number of cores # 0,75² # 1,5² # 2,5² dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km S-2YY 10x1,5 10 14,4 287 S-2YY 10x2,5 10 16,8 418 S-2YY 19x0,75 19 14,0 289 S-2YY 19x1,5 19 17,0 468 S-2YY 19x2,5 19 21,0 730 The cable is designed for use in railway protection systems, for underground laying and drawing into conduits. The cross section of this cable type goes from 0,75 to 25 mm². Conductor: Insulation: Colour code: Cable make up: Sheath: solid, bare copper wire PE (2Y) tracer core in each layer: blue other cores: transparent cores cabeld together in concentric layers, wrapping of tape PVC, grey (Y) PENGG KABEL - type- ÖBB sign - <meter> ; SIGNAL fills the free space for gaps, less then 10 cm Technical Details (at 20 C) Standard: ÖVE- K 10 / 10 06.95 Conductor cross section: 0,75 1,5 2,5 mm² Conductor resistance: 24,5 12,1 7,28 Ω/km Insulation resistance: 5 GΩkm Mutual capacitance: 100 120 120 nf/km conductor/conductor 2500 3500 3500 V/50Hz/2min conductor/shield 2500 3500 3500 V/50Hz/2min Operating voltage: 400 800 800 Veff Temperature range: during operation -30 to +60 C during installation -5 to +50 C 14 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Austrian Railways PE insulated, star-quad, with copper screening F-2Y2YC2Y..x2x0,8 C55 mutual capacity 6-40 0.8 dimension of conductor number of double cores filling Austrian Railways (ÖBB) cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km F-2Y2YC2Y 6x2x0,8 6 14 210 F-2Y2YC2Y 14x2x0,8 14 17 340 F-2Y2YC2Y 20x2x0,8 20 20 440 F-2Y2YC2Y 40x2x0,8 40 23 730 The cable is desigend as speaker cable for railway telecommunication. Conductor: solid, bare copper wire 0,8 mm Insulation: PE (2Y) Colour code: beginning quad other quads a core: BK transparent b core: RD RD c core: GN GN d core: BU BU Cable make up: cores twisted to quads, quads stranded together to the cable core, wrapping with tape Sheath: PE, black (2Y) Screening: one layer copper tape (C) Protective cover: PE, black (2Y) Technical Details (at 20 C) Standard: TL BB 002 / E-11.84 + Nt. 12.06 Conductor diameter: 0,8 mm Loop resistance: 72,3 Ω/km Screen resistance: 20 Ω Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 55 nf/km Capacitance unbalance: K 1 100% 800 pf/300m 95% 400 pf/300m K 9-12 300 pf/300m e a1/2 800 pf/300m conductor/conductor 2500 V/50Hz/2min conductor/shield 2500 V/50Hz/2min order number - type - ÖBB sign - <meter> - PENGG KABEL - month and year of production - handset symbol Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 15

Austrian Railways Note 16 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways, DB A-2YOF(L)2YB2Y..x1x.. S (H115/H145) page 19 AJ-2YOF(L)2YDB2Y..x1x0,9 S (H115) page 20 AJ-2YOF(L)2YDB2Y..x1x1,4 S (H145) page 21 AJ-2YOF(L)2YDB2Y..x1x1,8 S (H145) page 22 A-2YOF(L)2YB2Y..x1x.. S (H95) page 23 AJ-2YOF(L)2YDB2Y..x1x1,4 S (H95) page 24 AJ-2YOF(L)2YDB2Y..x1x1,8 S (H95) page 25 A-2Y2YV..x1x.. S (H115/H145) page 26 A-2Y2YB2Y..x1x.. S (H115/H145) page 27 AJ-2Y2YDB2Y..x1x0,9 S (H115) page 28 German Railways (DB) AJ-2Y2YDB2Y..x1x1,4 S (H145) page 29 AJ-2Y2YDB2Y..x1x1,8 S (H145) page 30 A-2Y2YV..x1x.. S (H95) page 31 A-2Y2YB2Y..x1x.. S (H95) page 32 AJ-2Y2YDB2Y..x1x1,4 S (H95) page 33 AJ-2Y2YDB2Y..x1x1,8 S (H95) page 34 A-2Y(L)2YV..x4x.. S (H45) page 35 A-2Y(L)2YB2Y..x4x.. S (H45) page 36 AJ-2Y(L)2YDB2Y..x4x0,9 S (H45) page 37 AJ-2Y(L)2YDB2Y..x4x1,4 S (H45) page 38 A-02YSTF(L)2YV..x4x0,9 STI TNP 02 page 39 A-02YSTF(L)2YV..x4x1,4 /..x4x0,9 STI A TNP 02 page 40 A-02YSTF(L)2YB2Y 5x4x0,9 STI TNP 02 page 41 A-02YSTF(L)2Y(SR)2Y 5x4x0,9 STI TNP 02 page 42 AJ-02YSTF(L)2YDB2Y..x4x0,9 STI A TNP 02 page 43 AJ-02YSTF(L)2YDB2Y..x4x1,4 /..x4x0,9 STI A TNP 02 page 44 A-02YS(L)2YV..x4x0,7 mm² STI TNP 03 page 45 A-02YS(L)2YB2Y..x4x0,7 mm² STI TNP 03 page 46 A-02YS(L)2Y(SR)2Y..x4x0,7 mm² STI TNP 03 page 47 A-02YS2Y(ST)(ZN)2Y..x4x0,9 STI TNP 04 page 48 A-02YSF(L)2YV 2x4x1,4 / 2x4x0,9 STI TNP 06 page 49 A-02YSF(L)2Y(SR)2Y 3x4x0,9mm STI TNP 06 page 50 A-2Y(L)2YB2Y 1x4x page 51 AJ-2Y(L)2YDB2Y 1x4x1,53 page 52 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 17

German Railways, DB A-2YF(L)2Y..x4x0,4 STIII BD page 53 A-02YSF(L)2Y..x2x.. STIII BD page 54 AJ-02YSF(L)2YDB2Y..x2x0,8 STIII BD page 55 18 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-insulated, single core, with rodent protection A-2YOF(L)2YB2Y..x1x.. S (H115/H145) 2-200 number of cores 0,9 1,4 1,8 dimension of conductor OF filling cable elements overall shield, armouring conductor diameter 0.9 mm conductor diameter 1.4 mm conductor diameter 1.8 mm Type number of outer diameter weight outer diameter weight outer diameter weight cores approx. mm approx. kg/km approx mm approx. kg/km approx. mm approx. kg/km A-2YOF(L)2YB2Y 2x1x.. S 2 13,0 160 - - - - A-2YOF(L)2YB2Y 4x1x.. S 4 13,0 170 14,0 240 16,0 300 A-2YOF(L)2YB2Y 7x1x.. S 7 14,0 220 17,0 320 19,0 430 A-2YOF(L)2YB2Y 10x1x.. S 10 17,0 290 18,0 410 21,0 560 A-2YOF(L)2YB2Y 14x1x.. S 14 17,0 300 19,0 490 22,0 680 A-2YOF(L)2YB2Y 20x1x.. S 20 18,0 380 22,0 630 25,0 890 A-2YOF(L)2YB2Y 24x1x.. S 24 20,0 460 23,0 730 27,0 1060 A-2YOF(L)2YB2Y 30x1x.. S 30 20,0 490 24,0 840 29,0 1230 A-2YOF(L)2YB2Y 40x1x.. S 40 21,0 590 27,0 1050 32,0 1560 A-2YOF(L)2YB2Y 50x1x.. S 50 23,0 700 29,0 1280 36,0 1940 A-2YOF(L)2YB2Y 60x1x.. S 60 25,0 800 32,0 1490 38,0 2280 A-2YOF(L)2YB2Y 80x1x.. S 80 26,0 1000 35,0 1920 42,0 2920 A-2YOF(L)2YB2Y 100x1x.. S 100 31,0 1250 39,0 2350 47,0 3630 A-2YOF(L)2YB2Y 120x1x.. S 120 32,0 1390 41,0 2730 49,0 4230 A-2YOF(L)2YB2Y 140x1x.. S 140 35,0 1650 44,0 3140 53,0 4890 A-2YOF(L)2YB2Y 160x1x.. S 160 36,0 1790 46,0 3540 55,0 5490 A-2YOF(L)2YB2Y 180x1x.. S 180 39,0 2030 49,0 3970 59,0 6160 A-2YOF(L)2YB2Y 200x1x.. S 200 39,0 2150 50,0 4310 60,0 6710 German Railways (DB) For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 0,9 / 1,4 / 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent Cable make up: cores cabled together in concentric layers Filling: low capacity filling (OF), (longitudinal watertight) Laminated sheath: aluminium laminated PE-sheath ((L)2Y), black (transverse watertight) Armouring: 1 layer galvanized steel tape (0,3 mm) (B) for rodent protection Protective cover: PE (2Y), black Design: 2 up to 200 cores ( 0,9) 4 up to 200 cores ( 1,4 / 1,8) Technical Details (at 20 C) Standard: DB AG 416.0113 Conductor diameter: 0,9 1,4 1,8 mm Loop resistance: 28,9 11,9 7,2 Ω/km Insulation resistance: 1,5 1,5 1,5 GΩkm Mutual capacitance (at f=800hz): 115 145 145 nf/km (H115) (H145) (H145) Operating voltage: 600 600 600 V/DC 420 420 420 Veff/100Hz Dielectric strength (cond./cond.): 2500 2500 2500 V/AC/1min Dielectric strength (cond./shield): 2500 2500 2500 V/AC/1min Temperature range: during installation -10 to +60 C during operation -40 to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 19

German Railways PE-insulated, single core, with inductive protection AJ-2YOF(L)2YDB2Y..x1x0,9 S (H115) 10-200 number of cores 0,9 dimension of conductor OF filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2YOF(L)2YDB2Y 10x1x0,9 S (H115) 10 600 21,0 650 AJ-2YOF(L)2YDB2Y 20x1x0,9 S (H115) 20 600 22,0 750 AJ-2YOF(L)2YDB2Y 30x1x0,9 S (H115) 30 600 24,0 900 AJ-2YOF(L)2YDB2Y 50x1x0,9 S (H115) 50 600 27,0 1190 AJ-2YOF(L)2YDB2Y 80x1x0,9 S (H115) 80 600 30,0 1560 AJ-2YOF(L)2YDB2Y 120x1x0,9 S (H115) 120 600 35,0 2040 AJ-2YOF(L)2YDB2Y 160x1x0,9 S (H115) 160 600 39,0 2500 AJ-2YOF(L)2YDB2Y 200x1x0,9 S (H115) 200 600 41,0 2930 AJ-2YOF(L)2YDB2Y 10x1x0,9 S (H115) 10 500 21,0 750 AJ-2YOF(L)2YDB2Y 20x1x0,9 S (H115) 20 500 22,0 870 AJ-2YOF(L)2YDB2Y 30x1x0,9 S (H115) 30 500 24,0 1040 AJ-2YOF(L)2YDB2Y 50x1x0,9 S (H115) 50 500 27,0 1320 AJ-2YOF(L)2YDB2Y 80x1x0,9 S (H115) 80 500 30,0 1740 AJ-2YOF(L)2YDB2Y 120x1x0,9 S (H115) 120 500 35,0 2230 AJ-2YOF(L)2YDB2Y 160x1x0,9 S (H115) 160 500 39,0 2720 AJ-2YOF(L)2YDB2Y 200x1x0,9 S (H115) 200 500 41,0 3160 For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 0,9 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent Cable make up: cores cabled together in concentric layers Filling: low capacity filling (OF), (longitudinal watertight) Laminated sheath:: aluminium laminated PE-sheath ((L)2Y), black (transverse watertight) Screening: 1 layer copper wires ( 0,9 / 1,2) (D) wrapping of plastic tape Armouring: 2 layer galvanized steel tape (0,5) (B) Protective cover: PE (2Y), black Design: 10 up to 200 cores ( 0,9) Technical Details (at 20 C) Standard: DB AG 416.0113 Conductor diameter: 0,9 mm Loop resistance: 28,9 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 115 nf/km (H115) Reduction factor: acc.to DB AG 416.0116 Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Temperature range: during installation -10 to +60 C during operation -40 to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 20 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-insulated, single core, with inductive protection AJ-2YOF(L)2YDB2Y..x1x1,4 S (H145) 10-200 number of cores 1,4 dimension of conductor OF filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2YOF(L)2YDB2Y 10x1x1,4 S (H145) 10 600 22,0 790 AJ-2YOF(L)2YDB2Y 20x1x1,4 S (H145) 20 600 26,0 1090 AJ-2YOF(L)2YDB2Y 30x1x1,4 S (H145) 30 600 28,0 1350 AJ-2YOF(L)2YDB2Y 50x1x1,4 S (H145) 50 600 33,0 1890 AJ-2YOF(L)2YDB2Y 80x1x1,4 S (H145) 80 600 38,0 2630 AJ-2YOF(L)2YDB2Y 120x1x1,4 S (H145) 120 600 44,0 3560 AJ-2YOF(L)2YDB2Y 160x1x1,4 S (H145) 160 600 49,0 4460 AJ-2YOF(L)2YDB2Y 200x1x1,4 S (H145) 200 600 53,0 5290 AJ-2YOF(L)2YDB2Y 10x1x1,4 S (H145) 10 500 22,0 920 AJ-2YOF(L)2YDB2Y 20x1x1,4 S (H145) 20 500 26,0 1230 AJ-2YOF(L)2YDB2Y 30x1x1,4 S (H145) 30 500 28,0 1490 AJ-2YOF(L)2YDB2Y 50x1x1,4 S (H145) 50 500 33,0 2080 AJ-2YOF(L)2YDB2Y 80x1x1,4 S (H145) 80 500 38,0 2850 AJ-2YOF(L)2YDB2Y 120x1x1,4 S (H145) 120 500 45,0 3880 AJ-2YOF(L)2YDB2Y 160x1x1,4 S (H145) 160 500 50,0 4790 AJ-2YOF(L)2YDB2Y 200x1x1,4 S (H145) 200 500 54,0 5650 AJ-2YOF(L)2YDB2Y 50x1x1,4 S (H145) 50 400 36,0 2770 AJ-2YOF(L)2YDB2Y 80x1x1,4 S (H145) 80 400 42,0 3770 AJ-2YOF(L)2YDB2Y 120x1x1,4 S (H145) 120 400 48,0 4870 AJ-2YOF(L)2YDB2Y 160x1x1,4 S (H145) 160 400 53,0 5880 AJ-2YOF(L)2YDB2Y 200x1x1,4 S (H145) 200 400 57,0 6830 German Railways (DB) For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,4 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent Cable make up: cores cabled together in concentric layers Filling: low capacity filling (OF), (longitudinal watertight) Laminated sheath:: aluminium laminated PE-sheath ((L)2Y), black (transverse watertight) Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D) wrapping of plastic tape Armouring: 2 layer galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 200 cores ( 1,4) Technical Details (at 20 C) Standard: DB AG 416.0113 Conductor diameter: 1,4 mm Loop resistance: 11,9 Ω/km Insulation resistance: 10 GΩkm mutual capacitance (at f=800hz): 145 nf/km (H145) Reduction factor: acc. to DB AG 416.0116 Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Temperature range: during installation -10 to +60 C during operation -40 to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 20

German Railways PE-insulated, single core, with inductive protection AJ-2YOF(L)2YDB2Y..x1x1,8 S (H145) 10-200 number of cores 1,8 dimension of conductor OF filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2YOF(L)2YDB2Y 10x1x1,8 S (H145) 10 600 25,0 1010 AJ-2YOF(L)2YDB2Y 20x1x1,8 S (H145) 20 600 29,0 1420 AJ-2YOF(L)2YDB2Y 30x1x1,8 S (H145) 30 600 33,0 1840 AJ-2YOF(L)2YDB2Y 50x1x1,8 S (H145) 50 600 39,0 2670 AJ-2YOF(L)2YDB2Y 80x1x1,8 S (H145) 80 600 45,0 3770 AJ-2YOF(L)2YDB2Y 120x1x1,8 S (H145) 120 600 52,0 5210 AJ-2YOF(L)2YDB2Y 160x1x1,8 S (H145) 160 600 58,0 6600 AJ-2YOF(L)2YDB2Y 200x1x1,8 S (H145) 200 600 63,0 7900 AJ-2YOF(L)2YDB2Y 10x1x1,8 S (H145) 10 500 25,0 1150 AJ-2YOF(L)2YDB2Y 20x1x1,8 S (H145) 20 500 29,0 1570 AJ-2YOF(L)2YDB2Y 30x1x1,8 S (H145) 30 500 33,0 2010 AJ-2YOF(L)2YDB2Y 50x1x1,8 S (H145) 50 500 39,0 2870 AJ-2YOF(L)2YDB2Y 80x1x1,8 S (H145) 80 500 46,0 4090 AJ-2YOF(L)2YDB2Y 120x1x1,8 S (H145) 120 500 53,0 5560 AJ-2YOF(L)2YDB2Y 160x1x1,8 S (H145) 160 500 59,0 6980 AJ-2YOF(L)2YDB2Y 200x1x1,8 S (H145) 200 500 64,0 8320 AJ-2YOF(L)2YDB2Y 30x1x1,8 S (H145) 30 400 36,0 2690 AJ-2YOF(L)2YDB2Y 50x1x1,8 S (H145) 50 400 43,0 3800 AJ-2YOF(L)2YDB2Y 80x1x1,8 S (H145) 80 400 49,0 5100 AJ-2YOF(L)2YDB2Y 120x1x1,8 S (H145) 120 400 56,0 6730 AJ-2YOF(L)2YDB2Y 160x1x1,8 S (H145) 160 400 62,0 8290 AJ-2YOF(L)2YDB2Y 200x1x1,8 S (H145) 200 400 67,0 9730 For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent Cable make up: cores cabled together in concentric layers Filling: low capacity filling (OF), (longitudinal watertight) Laminated sheath:: aluminium laminated PE-sheath ((L)2Y), black (transverse watertight) Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D) wrapping of plastic tape Armouring: 2 layer galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 200 cores ( 0,9) Technical Details (at 20 C) Standard: DB AG 416.0113 Conductor diameter: 1,8 mm Loop resistance: 7,2 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz) 145 nf/km (H145) Reduction factor: acc. to DB AG 416.0116 Operating voltage: 60 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Temperature range: during installation -10 to +60 C during operation -40 to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 22 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-insulated, single core, with rodent protection A-2YOF(L)2YB2Y..x1x.. S (H95) 4-80 number of cores 1,4 1,8 dimension of conductor OF filling cable elements overall shield, armouring conductor diameter 1.4 mm conductor diameter 1.8 mm Type number of outer diameter weight outer diameter weight cores approx mm approx. kg/km approx. mm approx. kg/km German Railways (DB) A-2YOF(L)2YB2Y 4x1x.. S (H95) 4 16,0 280 18,0 360 A-2YOF(L)2YB2Y 7x1x.. S (H95) 7 18,0 370 20,0 500 A-2YOF(L)2YB2Y 10x1x.. S (H95) 10 21,0 490 25,0 680 A-2YOF(L)2YB2Y 14x1x.. S (H95) 14 22,0 590 26,0 830 A-2YOF(L)2YB2Y 20x1x.. S (H95) 20 25,0 750 30,0 1090 A-2YOF(L)2YB2Y 24x1x.. S (H95) 24 28,0 890 34,0 1300 A-2YOF(L)2YB2Y 30x1x.. S (H95) 30 29,0 1030 36,0 1530 A-2YOF(L)2YB2Y 40x1x.. S (H95) 40 33,0 1270 39,0 1910 A-2YOF(L)2YB2Y 50x1x.. S (H95) 50 36,0 1590 43,0 2360 A-2YOF(L)2YB2Y 60x1x.. S (H95) 60 39,0 1840 46,0 2780 A-2YOF(L)2YB2Y 80x1x.. S (H95) 80 43,0 2330 51,0 3570 For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,4 / 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent Cable make up: cores cabled together in concentric layers Filling: low capacity filling (OF), (longitudinal watertight) Laminated sheath:: aluminium laminated PE-sheath ((L)2Y), black (transverse watertight) Armouring: 1 layer galvanized steel tape (0,3 mm) (B) for rodent protection Protective cover: PE (2Y), black Design: 10 up to 20 cores ( 1,4) 10 up to 14 cores ( 1,8) Technical Details (at 20 C) Standard: DB AG 416.0114 Conductor diameter: 1,4 1,8 mm Loop resistance: 11,9 7,2 Ω/km Insulation resistance: 10 10 GΩkm Mutual capacitance (at f=800hz) 95 95 nf/km (H95) Operating voltage: 600 600 V/DC 420 420 Veff/100Hz Dielectric strength (cond./cond.) 2500 2500 V/50Hz/1min Temperature range: during installation -10 to +60 C during operation -40 to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 23

German Railways PE-insulated, single core, with inductive protection AJ-2YOF(L)2YDB2Y..x1x1,4 S (H95) 10-50 number of cores 1,4 dimension of conductor OF filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2YOF(L)2YDB2Y 10x1x1,4 S (H95) 10 500 25,0 1100 AJ-2YOF(L)2YDB2Y 14x1x1,4 S (H95) 14 500 26,0 1220 AJ-2YOF(L)2YDB2Y 20x1x1,4 S (H95) 20 500 29,0 1430 AJ-2YOF(L)2YDB2Y 30x1x1,4 S (H95) 30 500 33,0 1820 AJ-2YOF(L)2YDB2Y 50x1x1,4 S (H95) 50 500 39,0 2530 AJ-2YOF(L)2YDB2Y 30x1x1,4 S (H95) 30 400 37,0 2530 AJ-2YOF(L)2YDB2Y 50x1x1,4 S (H95) 50 400 43,0 3480 For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,4 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent Cable make up: cores cabled together in concentric layers Filling: low capacity filling (OF), (longitudinal watertight) Laminated sheath: aluminium laminated PE-sheath ((L)2Y), black (transverse watertight) Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,8) (D) wrapping of plastic tape Armouring: 2 layer galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 50 cores ( 1,8) Technical Details (at 20 C) Standard: DB AG 416.0114 Conductor diameter: 1,4 mm Loop resistance: 11,9 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 95 nf/km (H95) Reduction factor: acc. to DB AG 416.0116 Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Temperature range: during installation -10 to +60 C during operation -40 to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 24 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-insulated, single core, with inductive protection AJ-2YOF(L)2YDB2Y..x1x1,8 S (H95) 10-50 number of cores 1,8 dimension of conductor OF filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2YOF(L)2YDB2Y 10x1x1,8 S (H95) 10 500 29,0 1340 AJ-2YOF(L)2YDB2Y 14x1x1,8 S (H95) 14 500 30,0 1560 AJ-2YOF(L)2YDB2Y 20x1x1,8 S (H95) 20 500 33,0 1880 AJ-2YOF(L)2YDB2Y 30x1x1,8 S (H95) 30 500 39,0 2460 AJ-2YOF(L)2YDB2Y 50x1x1,8 S (H95) 50 500 47,0 3560 AJ-2YOF(L)2YDB2Y 30x1x1,8 S (H95) 30 400 43,0 3380 AJ-2YOF(L)2YDB2Y 50x1x1,8 S (H95) 50 400 50,0 4600 German Railways (DB) For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent Cable make up: cores cabled together in concentric layers Filling: low capacity filling (OF), (longitudinal watertight) Laminated sheath:: aluminium laminated PE-sheath ((L)2Y), black (transverse watertight) Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,8) (D) wrapping of plastic tape Armouring: 2 layer galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 50 cores ( 1,8) Technical Details (at 20 C) Standard: DB AG 416.0114 Conductor diameter: 1,8 mm Loop resistance: 7,2 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 95 nf/km (H95) Reduction factor: acc. to DB AG 416.0116 Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Temperature range: during installation -10 to +60 C during operation -40 to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 25

German Railways PE-insulated, core stranded, with reinforced sheath A-2Y2YV..x1x.. S (H115/H145) 2-200 number of cores 0,9 1,4 1,8 dimension of conductor filling cable elements overall shield, armouring conductor diameter 0.9 mm conductor diameter 1.4 mm conductor diameter 1.8 mm Type number of outer diameter weight outer diameter weight outer diameter weight cores approx. mm approx. kg/km approx mm approx. kg/km approx. mm approx. kg/km A-2Y2YV 2x1x.. S 2 9,0 60 - - - - A-2Y2YV 4x1x.. S 4 9,0 80 11,0 140 12,0 200 A-2Y2YV 7x1x.. S 7 11,0 120 12,0 200 14,0 300 A-2Y2YV 10x1x.. S 10 12,0 150 15,0 280 17,0 420 A-2Y2YV 14x1x.. S 14 13,0 180 16,0 370 18,0 560 A-2Y2YV 20x1x.. S 20 14,0 240 17,0 490 21,0 760 A-2Y2YV 24x1x.. S 24 15,0 280 19,0 570 22,0 900 A-2Y2YV 30x1x.. S 30 16,0 340 20,0 690 24,0 1090 A-2Y2YV 40x1x.. S 40 17,0 430 22,0 900 27,0 1430 A-2Y2YV 50x1x.. S 50 19,0 520 24,0 1100 29,0 1750 A-2Y2YV 60x1x.. S 60 20,0 600 26,0 1300 31,0 2070 A-2Y2YV 80x1x.. S 80 22,0 770 29,0 1690 35,0 2740 A-2Y2YV 100x1x.. S 100 25,0 960 33,0 2120 40,0 3390 A-2Y2YV 120x1x.. S 120 26,0 1110 35,0 2510 42,0 4040 A-2Y2YV 140x1x.. S 140 28,0 1290 37,0 2900 46,0 4670 A-2Y2YV 160x1x.. S 160 29,0 1460 39,0 3290 49,0 5350 A-2Y2YV 180x1x.. S 180 32,0 1640 42,0 3690 52,0 6010 A-2Y2YV 200x1x.. S 200 32,0 1800 43,0 4060 53,0 6640 For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 0,9 / 1,4 / 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE, reinforced (2YV), black Design: 2 up to 200 cores ( 0,9) 4 up to 200 cores ( 1,4 / 1,8) Laying Usable for underground laying and drawing into conduits. Technical Details (at 20 C) Standard: DB AG 416.0113 Conductor diameter: 0,9 1,4 1,8 mm Conductor resistance: 28,9 11,9 7,2 Ω/km Insulation resistance: 10 10 10 GΩkm Mutual capacitance (at f=800hz): 115 145 145 nf/km (H115) (H145) (H145) Operating voltage: 600 600 600 V/DC 420 420 420 Veff/100Hz Dielectric strength (cond./cond.) 2500 2500 2500 V/AC/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.) 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 26 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-insulated, single core, with rodent protection A-2Y2YB2Y..x1x.. S (H115/H145) 2-140 number of cores 0,9 1,4 1,8 dimension of conductor filling cable elements overall shield, armouring conductor diameter 0.9 mm conductor diameter 1.4 mm conductor diameter 1.8 mm Type number of outer diameter weight outer diameter weight outer diameter weight cores approx. mm approx. kg/km approx mm approx. kg/km approx. mm approx. kg/km German Railways (DB) A-2Y2YB2Y 2x1x.. S 2 12,0 130 - - - - A-2Y2YB2Y 4x1x.. S 4 13,0 150 14,0 210 15,5 290 A-2Y2YB2Y 7x1x.. S 7 14,0 170 15,5 290 17,0 410 A-2Y2YB2Y 10x1x.. S 10 15,5 220 18,0 380 20,0 540 A-2Y2YB2Y 14x1x.. S 14 16,0 280 19,0 470 21,0 720 A-2Y2YB2Y 20x1x.. S 20 17,0 340 21,0 620 24,0 950 A-2Y2YB2Y 24x1x.. S 24 19,0 400 22,0 740 26,0 1090 A-2Y2YB2Y 30x1x.. S 30 19,0 460 23,0 860 27,0 1300 A-2Y2YB2Y 40x1x.. S 40 20,0 550 25,0 1080 30,0 1670 A-2Y2YB2Y 50x1x.. S 50 22,0 680 28,0 1320 - - A-2Y2YB2Y 60x1x.. S 60 23,0 770 30,0 1520 - - A-2Y2YB2Y 80x1x.. S 80 25,0 970 - - - - A-2Y2YB2Y 100x1x.. S 100 28,0 1170 - - - - A-2Y2YB2Y 120x1x.. S 120 29,0 1350 - - - - A-2Y2YB2Y 140x1x.. S 140 31,0 1540 - - - - For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 0,9 / 1,4 / 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE (2Y), black Armouring: 1 layer galvanized steel tape (0,3 mm) (B) for rodent protection Protective cover: PE (2Y), black Design: 2 up to 140 cores ( 0,9) 4 up to 60 cores ( 1,4) 4 up to 40 cores ( 1,8) Technical Details (at 20 C) Standard: DB AG 416.0113 Conductor diameter: 0,9 1,4 1,8 mm Conductor resistance: 28,9 11,9 7,2 Ω/km Insulation resistance: 10 10 10 GΩkm Mutual capacitance (at f=800hz): 115 145 145 nf/km (H115) (H145) (H145) Operating voltage: 600 600 600 V/DC 420 420 420 Veff/100Hz Dielectric strength (cond./cond.): 2500 2500 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 27

German Railways PE-insulated, single core, with inductive protection AJ-2Y2YDB2Y..x1x0,9 S (H115) 10-200 number of cores 0,9 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y2YDB2Y 10x1x0,9 S (H115) 10 600 19,0 620 AJ-2Y2YDB2Y 20x1x0,9 S (H115) 20 600 20,0 780 AJ-2Y2YDB2Y 30x1x0,9 S (H115) 30 600 22,0 940 AJ-2Y2YDB2Y 50x1x0,9 S (H115) 50 600 25,0 1240 AJ-2Y2YDB2Y 80x1x0,9 S (H115) 80 600 29,0 1600 AJ-2Y2YDB2Y 120x1x0,9 S (H115) 120 600 32,0 2100 AJ-2Y2YDB2Y 160x1x0,9 S (H115) 160 600 35,0 2550 AJ-2Y2YDB2Y 200x1x0,9 S (H115) 200 600 38,0 2980 AJ-2Y2YDB2Y 10x1x0,9 S (H115) 10 500 19,0 690 AJ-2Y2YDB2Y 20x1x0,9 S (H115) 20 500 20,0 880 AJ-2Y2YDB2Y 30x1x0,9 S (H115) 30 500 22,0 1070 AJ-2Y2YDB2Y 50x1x0,9 S (H115) 50 500 25,0 1380 AJ-2Y2YDB2Y 80x1x0,9 S (H115) 80 500 29,0 1770 AJ-2Y2YDB2Y 120x1x0,9 S (H115) 120 500 32,0 2290 AJ-2Y2YDB2Y 160x1x0,9 S (H115) 160 500 35,0 2750 AJ-2Y2YDB2Y 200x1x0,9 S (H115) 200 500 38,0 3180 For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 0,9 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE (2Y), black Screening: 1 layer copper wires ( 0,9 / 1,2) (D) wrapping of plastic tape Armouring: 2 layers galvanized steel tape (0,5) (B) Protective cover: PE (2Y), black Design: 10 up to 200 cores ( 0,9) Laying Usable for underground laying and drawing into conduits. Technical Details (at 20 C) Standard: DB AG 416.0113 Conductor diameter: 0,9 mm Conductor resistance: 28,9 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 115 nf/km (H115) Reduction factor: acc. DB AG 416.0116 Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 28 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-insulated, single core, with inductive protection AJ-2Y2YDB2Y..x1x1,4 S (H145) 10-200 number of cores 1,4 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y2YDB2Y 10x1x1,4 S (H145) 10 600 21,0 840 AJ-2Y2YDB2Y 20x1x1,4 S (H145) 20 600 23,5 1180 AJ-2Y2YDB2Y 30x1x1,4 S (H145) 30 600 27,0 1460 AJ-2Y2YDB2Y 50x1x1,4 S (H145) 50 600 31,0 2030 AJ-2Y2YDB2Y 80x1x1,4 S (H145) 80 600 35,0 2800 AJ-2Y2YDB2Y 120x1x1,4 S (H145) 120 600 41,0 3810 AJ-2Y2YDB2Y 160x1x1,4 S (H145) 160 600 46,0 4760 AJ-2Y2YDB2Y 200x1x1,4 S (H145) 200 600 49,0 5700 AJ-2Y2YDB2Y 10x1x1,4 S (H145) 10 500 21,0 950 AJ-2Y2YDB2Y 20x1x1,4 S (H145) 20 500 23,5 1300 AJ-2Y2YDB2Y 30x1x1,4 S (H145) 30 500 26,0 1610 AJ-2Y2YDB2Y 50x1x1,4 S (H145) 50 500 31,0 2220 AJ-2Y2YDB2Y 80x1x1,4 S (H145) 80 500 35,0 3000 AJ-2Y2YDB2Y 120x1x1,4 S (H145) 120 500 42,0 4080 AJ-2Y2YDB2Y 160x1x1,4 S (H145) 160 500 46,0 5060 AJ-2Y2YDB2Y 200x1x1,4 S (H145) 200 500 49,0 6020 AJ-2Y2YDB2Y 50x1x1,4 S (H145) 50 400 33,0 2970 AJ-2Y2YDB2Y 80x1x1,4 S (H145) 80 400 38,0 3960 AJ-2Y2YDB2Y 120x1x1,4 S (H145) 120 400 44,0 5170 AJ-2Y2YDB2Y 160x1x1,4 S (H145) 160 400 48,0 6280 AJ-2Y2YDB2Y 200x1x1,4 S (H145) 200 400 52,0 7300 German Railways (DB) For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,4 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE (2Y), black Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D) wrapping of plastic tape Armouring: 2 layers galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 200 cores ( 1,4) Laying Usable for underground laying and drawing into conduits. Technical Details (at 20 C) Standard: DB AG 416.0113 Conductor diameter: 1,4 mm Conductor resistance: 11,9 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 145 nf/km (H145) Reduction factor: acc. DB AG 416.0116 Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 29

German Railways PE-insulated, single core, with inductive protection AJ-2Y2YDB2Y..x1x1,8 S (H145) 10-200 number of cores 1,8 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y2YDB2Y 10x1x1,8 S (H145) 10 600 23,0 950 AJ-2Y2YDB2Y 20x1x1,8 S (H145) 20 600 27,0 1400 AJ-2Y2YDB2Y 30x1x1,8 S (H145) 30 600 30,0 1770 AJ-2Y2YDB2Y 50x1x1,8 S (H145) 50 600 36,0 2550 AJ-2Y2YDB2Y 80x1x1,8 S (H145) 80 600 41,0 3620 AJ-2Y2YDB2Y 120x1x1,8 S (H145) 120 600 48,0 5010 AJ-2Y2YDB2Y 160x1x1,8 S (H145) 160 600 54,0 6350 AJ-2Y2YDB2Y 200x1x1,8 S (H145) 200 600 58,0 7600 AJ-2Y2YDB2Y 10x1x1,8 S (H145) 10 500 23,0 1050 AJ-2Y2YDB2Y 20x1x1,8 S (H145) 20 500 27,0 1540 AJ-2Y2YDB2Y 30x1x1,8 S (H145) 30 500 30,0 1930 AJ-2Y2YDB2Y 50x1x1,8 S (H145) 50 500 36,0 2730 AJ-2Y2YDB2Y 80x1x1,8 S (H145) 80 500 42,0 3860 AJ-2Y2YDB2Y 120x1x1,8 S (H145) 120 500 49,0 5290 AJ-2Y2YDB2Y 160x1x1,8 S (H145) 160 500 55,0 6660 AJ-2Y2YDB2Y 200x1x1,8 S (H145) 200 500 59,0 7960 AJ-2Y2YDB2Y 30x1x1,8 S (H145) 30 400 32,0 2560 AJ-2Y2YDB2Y 50x1x1,8 S (H145) 50 400 38,0 3630 AJ-2Y2YDB2Y 80x1x1,8 S (H145) 80 400 44,0 4850 AJ-2Y2YDB2Y 120x1x1,8 S (H145) 120 400 51,0 6410 AJ-2Y2YDB2Y 160x1x1,8 S (H145) 160 400 57,0 7910 AJ-2Y2YDB2Y 200x1x1,8 S (H145) 200 400 61,0 9300 For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE (2Y), black Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D) wrapping of plastic tape Armouring: 2 layers galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 200 cores ( 0,9) Laying Usable for underground laying and drawing into conduits. Technical Details (at 20 C) Standard: DB AG 416.0113 Conductor diameter: 1,8 mm Conductor resistance: 7,2 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 145 nf/km (H145) Reduction factor: acc. DB AG 416.0116 Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 30 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-insulated, single core, with reinforced sheath A-2Y2YV..x1x.. S (H95) 10-50 number of cores 1,4 1,8 dimension of conductor filling cable elements overall shield, armouring conductor diameter 1.4 mm conductor diameter 1.8 mm Type number of outer diameter weight outer diameter weight cores approx mm approx. kg/km approx. mm approx. kg/km German Railways (DB) A-2Y2YV 10x1x.. S (H95) 10 16,0 320 19,0 470 A-2Y2YV 14x1x.. S (H95) 14 18,0 420 21,0 640 A-2Y2YV 20x1x.. S (H95) 20 20,0 570 24,0 860 A-2Y2YV 30x1x.. S (H95) 30 24,0 800 28,0 1240 A-2Y2YV 50x1x.. S (H95) 50 29,0 1270 36,0 2010 For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,4 / 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE, reinforced (2YV), black Design: 10 up to 50 cores ( 1,4 / 1,8) Laying Usable for underground laying and drawing into conduits. Technical Details (at 20 C) Standard: DB AG 416.0114 Conductor diameter: 1,4 1,8 mm Conductor resistance: 11,9 7,2 Ω/km Insulation resistance: 10 10 GΩkm Mutual capacitance (at f=800hz): 95 95 nf/km (H95) Operating voltage: 600 600 V/DC 420 420 Veff/100Hz Dielectric strength (cond./cond.): 2500 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 31

German Railways PE-insulated, single core, with rodent protection A-2Y2YB2Y..x1x.. S (H95) 10-20 number of cores 1,4 1,8 dimension of conductor filling cable elements overall shield, armouring conductor diameter 1.4 mm conductor diameter 1.8 mm Type number of outer diameter weight outer diameter weight cores approx mm approx. kg/km approx. mm approx. kg/km A-2Y2YB2Y 10x1x.. S (H95) 10 18,0 450 21,0 650 A-2Y2YB2Y 14x1x.. S (H95) 14 20,0 570 23,0 820 A-2Y2YB2Y 20x1x.. S (H95) 20 22,0 750 - - For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: Insulation: Colour code: Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire 1,4 / 1,8 mm PE (2Y) tracer core in each layer: blue other cores: transparent monitoring core: grey cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape PE (2Y), black 1 layer galvanized steel tape (0,3 mm) (B) for rodent protection PE (2Y), black Design: 10 up to 20 cores ( 1,4) 10 up to 14 cores ( 1,8) Technical Details (at 20 C) Standard: DB AG 416.0114 Conductor diameter: 1,4 1,8 mm Conductor resistance: 11.9 7.2 Ω/km Insulation resistance: 10 10 GΩkm Mutual capacitance (at f=800hz): 95 95 nf/km (H95) Operating voltage: 600 600 V/DC 420 420 Veff/100Hz Dielectric strength (cond./cond.): 2500 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz:) N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 32 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-insulated, single core, with inductive protection AJ-2Y2YDB2Y..x1x1,4 S (H95) 10-50 number of cores 1,4 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y2YDB2Y 10x1x1,4 S (H95) 10 500 22,0 990 AJ-2Y2YDB2Y 14x1x1,4 S (H95) 14 500 24,0 1130 AJ-2Y2YDB2Y 20x1x1,4 S (H95) 20 500 27,0 1360 AJ-2Y2YDB2Y 30x1x1,4 S (H95) 30 500 30,0 1680 AJ-2Y2YDB2Y 50x1x1,4 S (H95) 50 500 35,0 2300 AJ-2Y2YDB2Y 30x1x1,4 S (H95) 30 400 32,0 2350 AJ-2Y2YDB2Y 50x1x1,4 S (H95) 50 400 38,0 3180 German Railways (DB) For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,4 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE (2Y), black Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D) wrapping of plastic tape Armouring: 2 layers galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 50 cores ( 1,4) Laying Usable for underground laying and drawing into conduits. Technical Details (at 20 C) Standard: DB AG 416.0114 Conductor diameter: 1,4 mm Conductor resistance: 11,9 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 95 nf/km (H95) Reduction factor: acc. DB AG 416.0116 Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 33

German Railways PE-insulated, single core, with inductive protection AJ-2Y2YDB2Y..x1x1,8 S (H95) 10-50 number of cores 1,8 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y2YDB2Y 10x1x1,8 S (H95) 10 500 25,0 1380 AJ-2Y2YDB2Y 14x1x1,8 S (H95) 14 500 27,0 1620 AJ-2Y2YDB2Y 20x1x1,8 S (H95) 20 500 30,0 1990 AJ-2Y2YDB2Y 30x1x1,8 S (H95) 30 500 34,0 2550 AJ-2Y2YDB2Y 50x1x1,8 S (H95) 50 500 42,0 3670 AJ-2Y2YDB2Y 30x1x1,8 S (H95) 30 400 37,0 3510 AJ-2Y2YDB2Y 50x1x1,8 S (H95) 50 400 44,0 4780 For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE (2Y), black Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,8) (D) wrapping of plastic tape Armouring: 2 layers galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 50 cores ( 1,8) Laying Usable for underground laying and drawing into conduits. Technical Details (at 20 C) Standard: DB AG 416.0114 Conductor diameter: 1,8 mm Conductor resistance: 7,2 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 95 nf/km (H95) Reduction factor: acc. DB AG 416.0116 Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 34 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-insulated, star-quads, with reinforced sheath A-2Y(L)2YV..x4x.. S (H45) 2-80 number of double cores 0,9 1,4 dimension of conductor filling cable elements overall shield, armouring conductor diameter 0.9 mm conductor diameter 1.4 mm Type number of outer diameter weight outer diameter weight double cores approx mm approx. kg/km approx. mm approx. kg/km German Railways (DB) A-2Y(L)2YV 1x4x.. S 2 10,0 120 12,0 170 A-2Y(L)2YV 3x4x.. S 6 15,0 220 19,0 410 A-2Y(L)2YV 5x4x.. S 10 17,0 330 22,0 620 A-2Y(L)2YV 7x4x.. S 14 19,0 410 24,0 800 A-2Y(L)2YV 10x4x.. S 20 22,0 560 29,0 1090 A-2Y(L)2YV 14x4x.. S 28 25,0 730 33,0 1490 A-2Y(L)2YV 20x4x.. S 40 28,0 980 39,0 2040 A-2Y(L)2YV 30x4x.. S 60 34,0 1410 46,0 2950 A-2Y(L)2YV 40x4x.. S 80 38,0 1820 53,0 3900 For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of alternating currents up to 90 khz in systems, which require a high symmetry against each other and outside disturbers as well as in relation to the earth potential. Conductor: solid, bare copper wire 0,9 / 1,4 mm Insulation: PE (2Y) Identification: basic colour grey, ring marking according to DB AG 416.0116, monitoring cores: grey Cable make up: cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked with an open blue helix. 2 perforated cores ( 0,5 mm; in cables with 7 quads) wrapping of plastic tape tinned copper wire ( 0,4 mm) Sheath: aluminium laminated PE-sheath, reinforced ((L)2YV), black Design: 1 up to 40 quads ( 0,9 / 1,4) Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Technical Details (at 20 C) Standard: DB AG 416.0115 Conductor diameter: 0,9 1,4 mm Loop resistance: 56,6 23,4 Ω/km Insulation resistance: 10 10 GΩkm Mutual capacitance (at f=800hz): 45 45 nf/km (H45) Capacitance unbalance:k 1 100% 650 650 pf/500m (at f=800hz) 50% 150 pf/500m Capacitance unbalance:k 9-12 100% 500 500 pf/500m (at f=800hz) 50% 150 pf/500m Capacitance unbalance:e 1/2 100% 1300 1300 pf/500m (at f=800hz) e a1/2 100% 1300 1300 pf/500m Image attenuation constant: 100% 3,3 2,6 db/km (at f=90khz) FEXT: 100% 58 33 db/km (at f=90khz) 80% 62 db/km conductor/conductor 2500 2500 V/50Hz/1min conductor/shield 2500 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 35

German Railways PE-insulated, star-quads, with rodent protection A-2Y(L)2YB2Y..x4x.. S (H45) 2-28 number of double cores 0,9 1,4 dimension of conductor filling cable elements overall shield, armouring conductor diameter 0.9 mm conductor diameter 1.4 mm Type number of outer diameter weight outer diameter weight double cores approx mm approx. kg/km approx. mm approx. kg/km A-2Y(L)2YB2Y 1x4x.. S 2 12,0 190 14,0 260 A-2Y(L)2YB2Y 3x4x.. S 6 17,0 330 21,0 570 A-2Y(L)2YB2Y 5x4x.. S 10 19,0 470 24,0 820 A-2Y(L)2YB2Y 7x4x.. S 14 21,0 580 26,0 1020 A-2Y(L)2YB2Y 10x4x.. S 20 24,0 750 - - A-2Y(L)2YB2Y 14x4x.. S 28 27,0 940 - - For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of alternating currents up to 90 khz in systems, which require a high symmetry against each other and outside disturbers as well as in relation to the earth potential. Conductor: solid, bare copper wire 0,9 / 1,4 mm Insulation: PE (2Y) Identification: basic colour grey, ring marking according to DB AG 416.0116, monitoring cores: grey Cable make up: cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked with an open blue helix. 2 perforated cores ( 0,5 mm; in cables with 7 quads) wrapping of plastic tape tinned copper wire ( 0,4 mm) Sheath: aluminium laminated PE-sheath, ((L)2Y), black Armouring: 1 layer galvanized steel tape (0,3 mm) (B) for rodent protection Protective cover: PE (2Y), black Design: 1 up to 14 quads ( 0,9) 1 up to 7 quads ( 1,4) Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Technical Details (at 20 C) Standard: DB AG 416.0115 Conductor diameter: 0,9 1,4 mm Loop resistance: 56,6 23,4 Ω/km Insulation resistance: 10 10 GΩkm Mutual capacitance (at f=800hz): 45 45 nf/km (H45) Capacitance unbalance: k 1 100% 650 650 pf/500m (at f=800hz) 50% 150 pf/500m Capacitance unbalance: k 9-12 100% 500 500 pf/500m (at f=800hz) 50% 150 pf/500m Capacitance unbalance: e 1/2 100% 1300 1300 pf/500m (at f=800hz) e a1/2 100% 1300 1300 pf/500m Image attenuation constant: 100% 3.3 2.6 db/km (at f=90khz) FEXT: 100% 58 33 db/km (at f=90khz) 80% 62 db/km conductor/conductor 2500 2500 V/50Hz/1min conductor/shield 2500 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 36 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-insulated, star quads, with inductive protection AJ-2Y(L)2YDB2Y..x4x0,9 S (H45) 6-80 number of double cores 0,9 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight double cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y(L)2YDB2Y 3x4x0,9 S (H45) 6 600 21,0 800 AJ-2Y(L)2YDB2Y 5x4x0,9 S (H45) 10 600 23,0 1010 AJ-2Y(L)2YDB2Y 10x4x0,9 S (H45) 20 600 28,0 1430 AJ-2Y(L)2YDB2Y 20x4x0,9 S (H45) 40 600 35,0 2130 AJ-2Y(L)2YDB2Y 30x4x0,9 S (H45) 60 600 40,0 2800 AJ-2Y(L)2YDB2Y 40x4x0,9 S (H45) 80 600 45,0 3580 AJ-2Y(L)2YDB2Y 10x4x0,9 S (H45) 20 400 31,0 2250 AJ-2Y(L)2YDB2Y 20x4x0,9 S (H45) 40 400 38,0 3240 AJ-2Y(L)2YDB2Y 30x4x0,9 S (H45) 60 400 43,0 4080 AJ-2Y(L)2YDB2Y 40x4x0,9 S (H45) 80 400 48,0 4800 German Railways (DB) for general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of alternating currents up to 90 khz in systems, which require a high symmetry against each other and outside disturbers as well as in relation to the earth potential. Conductor: solid, bare copper wire 0,9 mm Insulation: PE (2Y) Identification: basic colour grey, ring marking according to DB AG 416.0116, monitoring cores: grey Cable make up: cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked with an open blue helix. 2 perforated cores ( 0,5 mm; in cables with 7 quads) wrapping of plastic tape tinned copper wire ( 0,4 mm) Sheath: aluminium laminated PE-sheath, ((L)2Y), black Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D) wrapping of plastic tape Armouring: 2 layers galvanized steel tape (0,5/0,8) (B) Protective cover: PE (2Y), black Design: 6 up to 80 double cores ( 0,9) Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Technical Details (at 20 C) Standard: DB AG 416.0115 Conductor diameter: 0,9 mm Loop resistance: 56,6 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 45 nf/km (H45) Capacitance unbalance: k 1 100% 650 pf/500m (at f=800hz) 50% 150 pf/500m Capacitance unbalance: k 9-12 100% 500 pf/500m (at f=800hz) 50% 150 pf/500m Capacitance unbalance: e 1/2 100% 1300 pf/500m (at f=800hz) e a1/2 100% 1300 pf/500m Image attenuation constant: 100% 3.3 db/km (at f=90khz) FEXT: 100% 58 db/km (at f=90khz) 80% 62 db/km conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 37

German Railways PE-insulated, star quads, with inductive protection AJ-2Y(L)2YDB2Y..x4x1,4 S (H45) 6-80 number of double cores 1,4 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight double cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y(L)2YDB2Y 3x4x1,4 S (H45) 6 500 25,0 1350 AJ-2Y(L)2YDB2Y 5x4x1,4 S (H45) 10 500 29,0 1760 AJ-2Y(L)2YDB2Y 10x4x1,4 S (H45) 20 500 37,0 2620 AJ-2Y(L)2YDB2Y 20x4x1,4 S (H45) 40 500 47,0 4040 AJ-2Y(L)2YDB2Y 30x4x1,4 S (H45) 60 500 54,0 5330 AJ-2Y(L)2YDB2Y 40x4x1,4 S (H45) 80 500 61,0 6550 AJ-2Y(L)2YDB2Y 5x4x1,4 S (H45) 10 400 31,0 2470 AJ-2Y(L)2YDB2Y 10x4x1,4 S (H45) 20 400 39,0 3610 AJ-2Y(L)2YDB2Y 20x4x1,4 S (H45) 40 400 49,0 5260 AJ-2Y(L)2YDB2Y 30x4x1,4 S (H45) 60 400 56,0 6690 AJ-2Y(L)2YDB2Y 40x4x1,4 S (H45) 80 400 63,0 8070 For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of alternating currents up to 90 khz in systems, which require a high symmetry against each other and outside disturbers as well as in relation to the earth potential. Conductor: solid, bare copper wire 1,4 mm Insulation: PE (2Y) Identification: basic colour grey, ring marking according to DB AG 416.0116, monitoring cores: grey Cable make up: cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked with an open blue helix. 2 perforated cores ( 0,5 mm; in cables with 7 quads) wrapping of plastic tape tinned copper wire ( 0,4 mm) Sheath: aluminium laminated PE-sheath ((L)2Y), black. Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D) wrapping of plastic tape Armouring: 2 layers galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 6 up to 80 double cores ( 0,9) Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Technical Details (at 20 C) Standard: DB AG 416.0115 Conductor diameter: 1,4 mm Loop resistance: 23,4 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 45 nf/km (H45) Capacitance unbalance: k 1 100% 650 pf/500m (at f=800hz) Capacitance unbalance: k 9-12 100% 500 pf/500m (at f=800hz) Capacitance unbalance: e 1/2 100% 1300 pf/500m (at f=800hz) e a1/2 100% 1300 pf/500m Image attenuation constant: 100% 2,6 db/km (at f=90khz) FEXT 100% 33 db/km (at f=90khz) conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 38 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-foam skin insulated, star quads, reinforced sheath A-02YSTF(L)2YV..x4x0,9 STI TNP 02 C34 mutual capacitance 10-60 number of double cores 0,9 dimension of copper conductor TF filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YSTF(L)2YV 5x4x0,9 STI TNP 02 10 20,0 300 A-02YSTF(L)2YV 10x4x0,9 STI TNP 02 20 28,0 570 A-02YSTF(L)2YV 16x4x0,9 STI TNP 02 32 33,0 790 A-02YSTF(L)2YV 19x4x0,9 STI TNP 02 38 35,0 940 A-02YSTF(L)2YV 24x4x0,9 STI TNP 02 48 41,0 1170 A-02YSTF(L)2YV 30x4x0,9 STI TNP 02 60 43,0 1390 German Railways (DB) The cable is designed for use as railway signalling cable for long distances. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid, bare copper wire 0,9 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to star-quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), wrapping with swellable tape (TF) aluminium laminated PE-sheath, reinforced black ((L)2YV) Technical Details (at 20 C) Standard: Arcor TNP 02 Conductor diameter: 0,9 mm Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k 1 110 pf/km k 9-12 110 pf/km e a1/2 1300 pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db/abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 39

German Railways PE-foam skin insulated,star quads,with reinforced sheath A-02YSTF(L)2YV..x4x1,4 /..x4x0,9 STI A TNP 02 C36 C34 mutual capacitance 16-66 number of double cores 0.9 1.4 dimension of conductor TF filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YSTF(L)2YV 1x4x1,4 / 7x4x0,9 STI A TNP 02 16 25,0 510 A-02YSTF(L)2YV 2x4x1,4 / 11x4x0,9 STI A TNP 02 26 34,0 820 A-02YSTF(L)2YV 3x4x1,4 / 12x4x0,9 STI A TNP 02 30 35,0 940 A-02YSTF(L)2YV 4x4x1,4 / 13x4x0,9 STI A TNP 02 34 37,0 1080 A-02YSTF(L)2YV 5x4x1,4 / 16x4x0,9 STI A TNP 02 42 40,0 1300 A-02YSTF(L)2YV 3x4x1,4 / 30x4x0,9 STI A TNP 02 66 47,0 1690 The cable is designed for use as railway signalling cable for long distances. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid, bare copper wire 0,9 / 1,4 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to star-quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), wrapping with swellable tape (TF) aluminium laminated PE-sheath, reinforced, black ((L)2YV) Technical Details (at 20 C) Standard: Arcor TNP 02 Conductor diameter: 0,9 1,4 mm Loop resistance: 56,6 23,4 Ω/km Resistance difference: 0,30 0,20 Ω/km Insulation resistance: L>200m 10 10 GΩkm 100m L 200m 25 25 GΩkm L<100m 30 30 GΩkm Mutual capacitance: 34 36 nf/km Capacitance unbalance: k 1 110 110 pf/km k 9-12 110 110 pf/km e a1/2 1300 1300 pf/km Attenuation: 800 Hz 0,6 0,4 db/km Operating voltage: 250 250 V eff Near-end crosstalk: 45 45 db abs. Far-end crosstalk: 45 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min 40 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-foam skin insulated, star quads, with rodent protection A-02YSTF(L)2YB2Y 5x4x0,9 STI TNP 02 C34 mutual capacitance 10 number of double cores 0,9 dimension of copper conductor TF filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YSTF(L)2YB2Y 5x4x0,9 STI TNP 02 10 22,2 521 German Railways (DB) The cable is designed for use as railway signalling cable for long distances. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid, bare copper wire 0,9 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to star-quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), wrapping with swellable tape (TF) aluminium laminated PE-sheath, black ((L)2Y) one layer galvanized steel tape (B) PE, black (2Y) Technical Details (at 20 C) Standard: Arcor TNP 02 Conductor diameter: 0,9 mm Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k 1 110 pf/km k 9-12 110 pf/km e a1/2 1300 pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db/abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 41

German Railways PE-foam skin insulated, star quads, with rodent protection A-02YSTF(L)2Y(SR)2Y 5x4x0,9 STI TNP 02 C34 mutual capacitance 10 number of double cores 0.9 dimension of conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YSTF(L)2Y(SR)2Y 5x4x0,9 STI TNP 02 10 23,2 495,1 The cable is designed for use as railway signalling cable for long distances. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid, bare copper wire 0,9 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to star-quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), wrapping with swellable tape aluminium laminated PE-sheath, black ((L)2Y) one layer of corrugated steel tape ((SR)), wrapping of tape PE, black (2Y) Technical Details (at 20 C) Standard: Arcor TNP 02 Conductor diameter: 0,9 mm Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: L>200m 10 GΩkm 100m L 200m 25 GΩkm L<100m 30 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k 1 110 pf/km k 9-12 110 pf/km e a1/2 1300 pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min 42 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-foam skin insulated, star quads, with inductive protection AJ-02YSTF(L)2YDB2Y..x4x0,9 STI A TNP 02 C34 mutual capacitance 20-60 number of double cores 0,9 dimension of copper conductor TF filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km AJ-02YSTF(L)2YDB2Y 10x4x0,9 STI TNP 02 20 37,0 1730 AJ-02YSTF(L)2YDB2Y 16x4x0,9 STI TNP 02 32 41,0 2110 AJ-02YSTF(L)2YDB2Y 19x4x0,9 STI TNP 02 38 43,0 2260 AJ-02YSTF(L)2YDB2Y 24x4x0,9 STI TNP 02 48 49,0 2750 AJ-02YSTF(L)2YDB2Y 30x4x0,9 STI TNP 02 60 52,0 3060 German Railways (DB) The cable is designed for use as railway signalling cable for long distances. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Screening: Armouring: Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid, bare copper wire 0,9 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to star-quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), wrapping with swellable tape (TF) aluminium laminated PE-sheath, black ((L)2Y) 1 layer copper wires (D), wrapping with tape two layers of galvanized steel tape (B), wrapping of tape PE, black (2Y) Technical Details (at 20 C) Standard: Arcor TNP 02 Conductor diameter: 0,9 mm Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k 1 110 pf/km k 9-12 110 pf/km e a1/2 1300 pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db/abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Reduction factor: according to Arcor TNP 05 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 43

German Railways PE-foam skin insulated, quads, inductive protection AJ-02YSTF(L)2YDB2Y..x4x1,4 /..x4x0,9 STI A TNP 02 C34 C36 mutual capacitance 16-66 number of double cores 0.9 1.4 dimension of conductor TF filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km AJ-02YSTF(L)2YDB2Y 1x4x1,4 / 7x4x0.9 16 34.0 1490 AJ-02YSTF(L)2YDB2Y 2x4x1,4 / 11x4x0.9 26 42.0 2030 AJ-02YSTF(L)2YDB2Y 3x4x1,4 / 12x4x0.9 30 44.0 2140 AJ-02YSTF(L)2YDB2Y 4x4x1,4 / 13x4x0.9 34 46.0 2330 AJ-02YSTF(L)2YDB2Y 5x4x1,4 / 16x4x0.9 42 48.0 2580 AJ-02YSTF(L)2YDB2Y 3x4x1,4 / 30x4x0.9 66 56.0 3300 The cable is designed for use as railway signalling cable for long distances. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Screening: Armouring: Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid, bare copper wire 0,9 / 1,4 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to star-quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), wrapping with swellable tape (TF) aluminium laminated PE-sheath, black ((L)2Y) 1 layer copper wires, wrapping with tape (D) 2 layers galvanized steel tape (B), wrapping of tape PE, black (2Y) Technical Details (at 20 C) Standard: Arcor TNP 02 Conductor diameter: 0,9 1,4 mm Loop resistance: 56,6 23,4 Ω/km Resistance difference: 0,30 0,20 Ω/km Insulation resistance: L>200m 10 10 GΩkm 100m L 200m 25 25 GΩkm L<100m 30 30 GΩkm Mutual capacitance: 34 36 nf/km Capacitance unbalance: k 110 110 pf/km k 9-12 110 110 pf/km e a1/2 1300 1300 pf/km Attenuation: 800 Hz 0,6 0,4 db/km Operating voltage: 250 250 V eff Near-end crosstalk: 45 45 db abs. Far-end crosstalk: 45 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Reduction factor: according Arcor TNP 05 44 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-foam skin insulated, star quads, with reinforced sheath A-02YS(L)2YV x4x0,7 mm² STI TNP 03 C34 mutual capacitance 6-14 number of double cores # 0,7² dimension of copper conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YS(L)2YV 3x4x0,7 mm² STI TNP 03 6 20,0 290 A-02YS(L)2YV 5x4x0,7 mm² STI TNP 03 10 24,0 420 A-02YS(L)2YV 7x4x0,7 mm² STI TNP 03 14 26,0 510 German Railways (DB) The cable is designed for use as railway signalling cable for long distances, with high resistance against vibrations. The cable is fixed directly at the rail. Conductor: Insulation: Colour code : Cable make up: Screening/sheath: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol strand bare copper wire 0,7 mm² PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to quads, quads stranded together in concentric layers, 2 perforated cores (cross section 0,2 mm²), wrapping with tape tinned strand copper wire (cross section 0,2 mm²), one layer aluminium tape, PE-sheath black, reinforced ((L)2YV) Technical Details (at 20 C) Standard: Arcor TNP 03 Conductor cross section: 0,7 mm² Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k 1 110 pf/km k 9-12 110 pf/km e a1/2 1300 pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db/abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Copper wire resistance: 95 Ω/km Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 45

German Railways PE-foam skin insulated, star-quads, with rodent protection A-02YS(L)2YB2Y..x4x0,7mm² STI TNP 03 C34 mutual capacitance 6-14 number of double cores # 0,7² dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores (DC) approx. mm approx. kg/km A-02YS(L)2YB2Y 3x4x0,7mm² 6 24,0 500 A-02YS(L)2YB2Y 5x4x0,7mm² 10 28,0 660 A-02YS(L)2YB2Y 7x4x0,7mm² 14 30,0 790 The cable is designed for use as railway signalling cable for long distances, with high resistance against vibrations. The cable is fixed directly at the rail. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol strand bare copper wire 0,7 mm² PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to quads, quads stranded together in concentric layers, 2 perforated cores (0,2 mm²), wrapping with tape. tinned copper wire (0,2mm²), one layer aluminium tape, PE-sheath, black ((L)2Y) one layer of galvanized steel tape (B) PE, black (2Y) Technical Details (at 20 C) Standard: Arcor TNP 03 Conductor diameter: 0,7 mm² Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: L>200m 10 GΩkm 100m L 200m 25 GΩkm L<100m 30 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k 1 110 pf/km k 9-12 110 pf/km e a1/2 1300 pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω. abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Copper wire resistance: 95 Ω/km 46 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-foam skin insulated, star quads, with rodent protection A-02YS(L)2Y(SR)2Y x4x0,7 mm² STI TNP 03 C34 mutual capacitance 6-14 number of double cores # 0,7² dimension of copper conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YS(L)2Y(SR)2Y 3x4x0,7 mm² STI TNP 03 6 24,0 500 A-02YS(L)2Y(SR)2Y 5x4x0,7 mm² STI TNP 03 10 28,0 660 A-02YS(L)2Y(SR)2Y 7x4x0,7 mm² STI TNP 03 14 30,0 790 German Railways (DB) The cable is designed for use as railway signalling cable for long distances, with high resistance against vibrations. The cable is fixed directly at the rail. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol strand bare copper wire 0,7 mm² PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to quads, quads stranded together in concentric layers, 2 perforated cores (cross section 0,2 mm²), wrapping with tape tinned strand copper wire (cross section 0,2 mm²), one layer aluminium tape, PE-sheath black ((L)2Y) one layer corrugated steel tape ((SR)) PE, black (2Y) Technical Details (at 20 C) Standard: Arcor TNP 03 Conductor cross section: 0,7 mm² Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k 1 110 pf/km k 9-12 110 pf/km e a1/2 1300 pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db/abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Copper wire resistance: 95 Ω/km Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 47

German Railways PE-foam skin insulated, star-quads, with strain relief elements A-02YS2Y(ST)(ZN)2Y..x4x0,9mm STI TNP 04 C34 mutual capacitance 10-32 number of double cores 0.9 dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YS2Y(ST)(ZN)2Y 5x4x0,9mm 10 21,1 354,5 A-02YS2Y(ST)(ZN)2Y 7x4x0,9mm 14 22,8 434,1 A-02YS2Y(ST)(ZN)2Y 10x4x0,9mm 20 27,1 569,3 A-02YS2Y(ST)(ZN)2Y 12x4x0,9mm 24 28,4 660,1 A-02YS2Y(ST)(ZN)2Y 16x4x0,9mm 32 31,9 839,8 The cable is designed for use as railway signalling cable for long distances, only for overground laying and mounting poles. Conductor: Insulation: Colour code : Cable make up: Sheath: Screening: Strain relief/ Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid bare copper wire 0,9 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), wrapping with tape. PE, natural (2Y) tinned copper wire ( 0,4 mm), one layer aluminium tape ((ST)) Glasrovings/ PE, black ((ZN)2Y) Technical Details (at 20 C) Standard: Arcor TNP 04 Conductor diameter: 0,9 mm² Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: L>200m 10 GΩkm 100m L 200m 25 GΩkm L<100m 30 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k 1 110 pf/km k 9-12 110 pf/km e a1/2 1300 pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Copper wire resistance: 140 Ω/km 48 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-foam skin insulated, star-quads, with reinforced sheath A-02YSF(L)2YV 2x4x1,4 / 2x4x0,9 STI TNP 06 C34 C36 mutual capacitance 8 number of double cores 0.9 1.4 dimension of conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YSF(L)2YV 2x4x1,4 / 2x4x0.9 8 24.0 540 German Railways (DB) The cable is designed for use as railway signalling cable, preferable for the connection of railway connection boxes. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid, bare copper wire 0,9 / 1,4 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to star-quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), filled with petrolat (F), wrapping with tape, wrapping with swellable tape aluminium laminated, reinforced PE-sheath, black ((L)2YV) Technical Details (at 20 C) Standard: Arcor TNP 06 Conductor diameter: 0,9 1,4 mm Loop resistance: 56,6 23,4 Ω/km Resistance difference: 0,30 0,20 Ω/km Insulation resistance: L>200m 10 10 GΩkm 100m L 200m 25 25 GΩkm L<100m 30 30 GΩkm Mutual capacitance: 34 36 nf/km Capacitance unbalance: k 1 110 110 pf/km k 9-12 110 110 pf/km e a1/2 1300 1300 pf/km Attenuation: 800 Hz 0,6 0,4 db/km Operating voltage: 250 250 V eff Near-end crosstalk: 45 45 db abs. Far-end crosstalk: 45 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 49

German Railways PE-foam skin insulated, star-quads, with rodent protection A-02YSF(L)2Y(SR)2Y 3x4x0,9mm STI TNP 06 C34 mutual capacitance 6 number of double cores 0.9 dimension of conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores (DC) approx. mm approx. kg/km A-02YSF(L)2Y(SR)2Y 3x4x0,9mm 6 20,0 350 The cable is designed for use as railway signalling cable, preferable for theconnection of railway connection boxes. Useable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid bare copper wire 0,9 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), filled with petrolat (F), wrapping with tape, wrapping with swellable tape aluminium laminated PE-sheath, black ((L)2Y) one layer of corrugated steel tape ((SR)) PE, black (2Y) Technical Details (at 20 C) Standard: Arcor TNP 06 Conductor diameter: 0,9 mm² Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: L>200m 10 GΩkm 100m L 200m 25 GΩkm L<100m 30 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k 1 110 pf/km k 9-12 110 pf/km e a1/2 1300 pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min 50 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE insulated, star-quads, with rodent protection A-2Y(L)2YB2Y 1x4x mutual capacitance 2 number of double cores 1,4 1,53 dimension of copper conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-2Y(L)2YB2Y 1x4x1,4 2 14,0 260 A-2Y(L)2YB2Y 1x4x1,53 2 18,0 350 German Railways (DB) The cable is designed for use in signal systems (unless the application of special cables of signaltechnique is required), preferably for transmission of alternating currents in systems which needs a high symmetry against each other. Conductor: Insulation: Colour code : Cable make up: Screening: Armouring: Protective cover: solid, bare copper wire 1,4 / 1,53 mm PE (2Y) a core: transparent b core: transparent with one ring mark every 17 mm c core: transparent with two ring marks every 34 mm d core: transparent with two ring marks every 17 mm cores twisted to a quad, wrapping with tape one copper wire ( 0,4mm), aluminium laminated PEsheath, black ((L)2Y), one layer steel tape, galvanized (B) PE, black (2Y) SIGNAL / Eurobalise (alternating every 25 cm) - type - VDE reg. nr. - PENGG KABEL - <meter> Technical Details (at 20 C) Standard: DB AG 416.0120 Conductor diameter: 1,4 1,53 mm Loop resistance: 23,4 19,8 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: 52 43 nf/km Capacitance unbalance: k 1 650 240 pf/km e a1/2 1300 650 pf/km Operating voltage: DC 600 600 V AC 420 420 V/100 Hz Near-end crosstalk: 55 60 db Attenuation: 560 khz 7 4,2 db/km Impedance: 200-600 khz 120+/-10% 120+/-10% Ω conductor/conductor 2500 2500 V/50Hz/1min conductor/shield 2500 2500 V/50Hz/1min Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 51

German Railways PE-insulated, star-quads, with inductive protection AJ-2Y(L)2YDB2Y 1x4x1,53 C43 mutual capacitance 2 number of double cores 1.53 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight double cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y(L)2YDB2Y 1x4x1,53 2 600 22,0 740 AJ-2Y(L)2YDB2Y 1x4x1,53 2 500 22,0 830 AJ-2Y(L)2YDB2Y 1x4x1,53 2 400 24,0 1330 The cable is designed for use in signal systems (unless the application of special cables of signaltechnique is required), preferably for transmission of alternating currents in systems which needs a high symmetry against each other. Conductor: Insulation: Colour code : Cable make up: 1st Screening: 2nd Screening: Armouring: Protective cover: solid, bare copper wire 1,53 mm PE (2Y) a core: transparent b core: transparent with one ring mark every 17 mm c core: transparent with two ring marks every 34 mm d core: transparent with two ring marks every 17 mm cores twisted to a quad, wrapping with tape one copper wire ( 0,4mm), aluminium laminated PEsheath, black ((L)2Y) one layer copper wires, wrapping with tape (D) two layer steel tape, galvanized (B) PE, black (2Y) SIGNAL / Eurobalise (alternating every 25 cm) - type - VDE reg. nr. - PENGG KABEL - <meter> Technical Details (at 20 C) Standard: DB AG 416.0120 Conductor diameter: 1,53 mm Loop resistance: 19,8 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: 43 nf/km Capacitance unbalance: k 1 240 pf/km e a1/2 650 pf/km Operating voltage: DC 600 V AC 420 V/100 Hz Near-end crosstalk (1 MHz): 60 db Attenuation: 8,8 khz 0,8 db/km 280 khz 3,0 db/km 560 khz 4,2 db/km 1,8 MHz 8,0 db/km Impedance: 8,8 khz 147+/-15% Ω 200-600 khz 120+/-10% Ω 1,8 MHz 120+/-10% Ω Reduction factor: acc. to DB AG 416.0120 Temperature range during operation -40 up to +60 C during installation -10 up to +60 C 52 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-insulated, star-quads, reinforced sheath A-2YF(L)2Y..x4x0,4 STIII BD C50 mutual capacitance 6-200 number of double cores 0.4 dimension of conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-2YF(L)2Y 6x2x0.4 STIII BD 6 9.5 80 A-2YF(L)2Y 10x2x0.4 STIII BD 10 10.5 105 A-2YF(L)2Y 20x2x0.4 STIII BD 20 12.5 160 A-2YF(L)2Y 30x2x0.4 STIII BD 30 15.0 230 A-2YF(L)2Y 40x2x0.4 STIII BD 40 16.5 285 A-2YF(L)2Y 50x2x0.4 STIII BD 50 17.5 340 A-2YF(L)2Y 70x2x0.4 STIII BD 70 20.0 445 A-2YF(L)2Y 100x2x0.4 STIII BD 100 23.0 600 A-2YF(L)2Y 150x2x0.4 STIII BD 150 27.5 910 A-2YF(L)2Y 200x2x0.4 STIII BD 200 31.0 1165 German Railways (DB) The cable is designed for transmission of railway station signals. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Cable short mark: solid, bare copper wire 0,4 mm PE (2Y) a core: transparent b core: transparent with one ring mark every 17 mm c core: transparent with two ring marks every 34 mm d core: transparent with two ring marks every 17 mm cores twisted to quads, quads stranded together in concentric layer, filled with petrolat (F), wrapping with tape aluminium laminated PE-sheath, black ((L)2Y) star-quad stranding (STIII) bundle stranding (BD) Technical Details (at 20 C) Standard: Dlk 1.013.151 Conductor diameter: 0,4 mm Conductor loop resistance: 300 Ω/km Insulation resistance: 5 GΩkm Mutual capacitance (800Hz): 100% 50 nf/km 95% 48 nf/km Capacitance unbalance: k 1 100% 800 pf/300m k 1 98% 400 pf/300m k 9-12 100% 300 pf/300m k 9-12 98% 100 pf/300m Attenuation: 800 Hz 1,49 db/km conductor/shield 2000 V/50Hz/2min 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 53

German Railways PE-foam skin insulated, star-quads A-02YSF(L)2Y..x2x.. STIII BD C42 C42 mutual capacity 6-200 number of double cores 0.6 0.8 dimension of conductor F filling cable elements overall shield, armouring conductor diameter 0.6 mm conductor diameter 0.8 mm Type number of outer diameter weight outer diameter weight double cores approx mm approx. kg/km approx. mm approx. kg/km A-02YSF(L)2Y 6x2x.. 6 10,3 107,5 13,2 176,9 A-02YSF(L)2Y 10x2x.. 10 11,8 147,3 15,3 252,0 A-02YSF(L)2Y 20x2x.. 20 15,3 255,2 20,0 450,3 A-02YSF(L)2Y 30x4x.. 30 17,6 350,6 22,7 601,6 A-02YSF(L)2Y 40x4x.. 40 19,6 443,2 25,4 755,1 A-02YSF(L)2Y 50x4x.. 50 21,3 532,1 28,2 952,6 A-02YSF(L)2Y 70x4x.. 70 24,8 730,2 32,3 1273,9 A-02YSF(L)2Y 100x4x.. 100 28,6 991,7 38,8 1823,4 A-02YSF(L)2Y 200x4x.. 200 39,2 1876,5 51,8 3301,0 The cable is designed for transmission of railway station signals. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Cable short mark: solid, bare copper wire PE - foam skin (02YS) a core: transparent b core: transparent with one ring mark every 17 mm c core: transparent with two ring marks every 34 mm d core: transparent with two ring marks every 17 mm cores twisted to quads, quads stranded together in concentric layers, filled with petrolat (F), wrapping with tape aluminium laminated PE-sheath, black ((L)2Y) star-quad stranding (STIII) bundle stranding (BD) 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol Technical Details (at 20 C) Standard: Dlk 1.013.151 Conductor diameter: 0,6 0,8 mm Conductor loop resistance: 130 73,2 Ω/km Insulation resistance: 5 5 GΩkm Mutual capacitance (800Hz): 100% 42 42 nf/km 95% 40 40 nf/km 80% 38 38 nf/km Capacitance unbalance: k 1 100% 800 800 pf/300m k1 98% 400 400 pf/300m k 9-12 100% 300 300 pf/300m k 9-12 98% 100 100 pf/300m Attenuation: 800 Hz 0,91 0,69 db/km Dielectric strength conductor/conductor 500 500 V/50Hz/2min conductor/shield 200 2000 V/50Hz/2min Operating peak voltage: 225 225 V 54 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways PE-foam skin insulated, star-quads, with inductive protection AJ-02YSF(L)2YDB2Y..x2x0,8 STIII BD C42 mutual capacitance 6-200 number of double cores 0,8 dimension of copper conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km AJ-02YSF(L)2YDB2Y 10x2x0.8 STIII BD 10 24,2 1070,8 AJ-02YSF(L)2YDB2Y 20x2x0.8 STIII BD 20 29,1 1486,0 AJ-02YSF(L)2YDB2Y 30x2x0.8 STIII BD 30 31,9 1821,7 AJ-02YSF(L)2YDB2Y 40x2x0.8 STIII BD 40 35,3 2203,5 AJ-02YSF(L)2YDB2Y 50x2x0.8 STIII BD 50 38,7 2525,8 AJ-02YSF(L)2YDB2Y 70x2x0.8 STIII BD 70 45,0 3626,5 AJ-02YSF(L)2YDB2Y 100x2x0.8 STIII BD 100 50,2 4517,7 AJ-02YSF(L)2YDB2Y 200x2x0.8 STIII BD 200 66,3 6985,5 German Railways (DB) The cable is designed for transmission of railway station signals. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Screening: Armouring: Protective Cover: Cable short mark: solid, bare copper wire PE - foam skin (02YS) a core : transparent b core : transparent with one ring mark every 17 mm c core : transparent with two ring marks every 34 mm d core : transparent with two ring marks every 17 mm cores twisted to quads, quads stranded together in concentric layers, filled with petrolat (F), wrapping with tape aluminium laminated PE-sheath, black ((L)2Y) one layer copper wires (D), wrapping with tape two layers of steel tape (B) PE, black (2Y) star-quad stranding (STIII) bundle stranding (BD) 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol Technical Details (at 20 C) Standard: Dlk 1.013.151 Conductor diameter: 0,8 mm Conductor loop resistance: 73,2 Ω/km Insulation resistance: 5 GΩkm Mutual capacitance (800Hz): 100% 42 nf/km 95% 40 nf/km 80% 38 nf/km Capacitance unbalance k 1 100% 800 pf/300m k 1 98% 400 pf/300m k 9-12 100% 300 pf/300m k 9-12 98% 100 pf/300m Attenuation: 800 Hz 0,69 db/km Dielectric strength conductor/conductor 500 V/50Hz/2min conductor/shield 2000 V/50Hz/2min Operating peak voltage: 225 V Reduction factor: acc. Dlk 1.013.151 and Dlk 1.01.104 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 55

German Railways Note 56 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

French Railways, SNCF ZPAU - px ² page 58 MD4 x4x0,8 page 59 ZPFU-...px1² page 60 ZUG-S...P...² page 61 ZUT-S...P...² page 62 4D... page 63 French Railways (SNCF) Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 57

French Railways PE insulated, pairs, with inductive protection ZPAU - px ² mutual capacity 1-56 number of double cores # 1² # 2,5² dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km ZPAU 1px2,5² 1 21,2 763 ZPAU 4px1² 4 23,8 620 ZPAU 7px1² 7 26,7 944 ZPAU 14px1² 14 31,0 1384 ZPAU 21px1² 21 35,5 1731 ZPAU 28px1² 28 39,5 2122 ZPAU 56px1² 56 49,5 3290 The cable is designed for the connection of the control center to the equipment shelters. Conductor: Insulation: Colour code: Cable make up: Sheath: Screening: Armouring: Protective cover: solid, bare copper wire PE a core: transparent b core: BK - BE - YE - RD - GN cores twisted to pairs., pairs stranded together to the cable core, wrapping with tape PE, transparent one layer copper tape; PE transparent two layers steel tape PE, black type - CT 445 - PENGG KABEL - month/year of production - <meter> - RESEAU FERRE DE FRANCE Technical Details (at 20 C) Standard: SNCF CT 445 Conductor cross section: 1 2,5 mm² Conductor resistance: 18,1 7,41 Ω/km Insulation resistance: 5 5 GΩkm Mutual capacitance: 1000 (+/-200) Hz 55 nf/km 8,9 khz 45 nf/km Capacitance unbalance: 200 300 pf/500m Reduction factor: according to SNCF CT 445 Attenuation: 45 khz 2,5 db/km 560 khz 3,8 db/km Impedance: 800Hz 120+/-10 Ω 8,9 khz 130+/-10 Ω conductor/conductor 3000 V/DC/3min conductor/shield 3000 V/DC/3min 58 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

French Railways PE-foam skin insulated, star quads, with inductive protection MD4 x4x0,8 C49 mutual capacity 14-56 number of double cores 0.8 dimension of conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km MD4 7x4x0,8 14 23,7 773 MD4 14x4x0,8 28 28,5 1277 MD4 21x4x0,8 42 33,3 1787 MD4 28x4x0,8 56 34,0 1913 The cable is designed for long distance telecommunications alongside railway lines. Conductor: Insulation: Colour code: Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire 0,8 mm PE-foam skin a core: GY - OG b core: WH - YE - BK - GN - BU - BN - RD c core: VT d core: BU - BN - RD - WH - YE - BK - GN cores twisted to pairs, pairs cabled together to a bundel, bundels stranded to the cable core, wrapping with tape petrol jelly, one tinnend copper wire, wrapping with tape; PE transparent two layers steel tape, wrapping with tape PE, black <meter> - "RFF" - type - "2328" - "ed4"- PENGG KABEL - year of production Technical Details (at 20 C) Standard: SNCF TL DCG N 2328 Ed.04 Conductor diameter: 0,8 mm Conductor resistance: 35,6 Ω/km Insulation resistance: 15 GΩkm Mutual capacitance (at f=800hz): 49 nf/km max 51 nf/km min 46 nf/km Capacitance unbalance: k 1 50 pf/1450m max 340 pf/1450m k 9-12 30 pf/1450m max 340 pf/1450m e a1/2 200 pf/1450m max 1025 pf/1450m Reduction factor: acc. to SNCF TL DCG N 2328 Ed.04 Attenuation: 1MHz 15,9 db/km Impedance: 800Hz 520+/-10% Ω/km conductor/conductor 1500 V/DC/1min conductor/shield 3000 V/DC/1min conductor/shield 3750 V/DC/3sek French Railways (SNCF) Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 59

French Railways PE insulated, pairs, with armouring ZPFU - px1² C 55 mutual capacity 1-56 number of double cores # 1² dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km ZPFU 1px1² 1 12,5 186 ZPFU 1px1² 2 13,6 248 ZPFU 4px1² 4 17,3 369 ZPFU 7px1² 7 20,8 695 ZPFU 14px1² 14 27,0 1083 ZPFU 21px1² 21 29,9 1363 ZPFU 28px1² 28 33,4 1668 ZPFU 56px1² 56 43,8 2752 The cable is designed for the connection of the control center to the equipment shelters. Conductor: Insulation: Colour code: Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire PE a core: transparent b core: BK - BE - YE - RD - GN cores twisted to pairs, pairs stranded together to the cable core, wrapping with tape PE, transparent two layers steel tape, wrapping with tape PE, black type - CT 445 - PENGG KABEL - month/year of production - <meter> - PRO- PRIETE RFF Technical Details (at 20 C) Standard: SNCF CT 445 Conductor cross section: 1 mm² Conductor resistance: 18,1 Ω/km Insulation resistance: 5 GΩkm Mutual capacitance: 1000 (+/-200) Hz 55 nf/km Capacitance unbalance: 200 pf/500m Attenuation: 45 khz 2,5 db/km Impedance: 800Hz 120+/-10 Ω conductor/conductor 3000 V/DC/3min conductor/shield 3000 V/DC/3min 60 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

French Railways PVC insulated, pair stranded ZUG-S P ² mutual capacity 1-12 number of double cores # 0,38² # 1² dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km ZUG-S 1P1² 1 6,8 58 ZUG-S 3P1² 3 9,4 113 ZUG-S 6P1² 6 12,3 201 ZUG-S 12P1² 12 15,9 357 ZUG-S 28P0,38² 28 15,7 335 The cable is designed for connection of railway network equipments in the traffic control center. Conductor: Insulation: Colour code: Cable make up: Sheath: strand tinned copper wire PVC a core: WH b core: BK - BU - YE -BN - RD - GN cores twisted to pairs, pairs stranded together to the cable core, wrapping with tape PVC, black Technical Details (at 20 C) Standard: SNCF CT 455 Conductor cross section: 0,38 1 mm² Loop resistance: 20,1 52,5 Ω/km conductor/conductor 2500 2500 V/50Hz/3min French Railways (SNCF) type - CT 455 - PENGG KABEL - month and year of production - <meter> Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 61

French Railways PVC insulated, star-quad, with inductive protection ZUT-S P ² mutual capacity 2-12 number of double cores # 1² dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km ZUT-S 2P1² 2 8,2 134 ZUT-S 6P1² 6 14,0 280 ZUT-S 12P1² 12 18,0 445 The cable is designed for connection of railway network equipments in the traffic control center. Conductor: Insulation: Colour code: Cable make up: Screening: Sheath: strand tinned copper wire PVC a core: WH b core: BK c core: YE d core: BU cores twisted to a quad, wrapping with tape tinned copper netting (8x0,2mm), wrapping with tape PVC, black Technical Details (at 20 C) Standard: SNCF CT 455 Conductor cross section: 1 mm² Loop resistance: 52,5 Ω/km conductor/conductor 2500 V/50Hz/3min type - CT 455 - PENGG KABEL - month and year of production - <meter> 62 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

French Railways PE insulated, star quads, with rodent protection 4D C50 mutual capacity 8-28 number of double cores 0.8 dimension of conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km 4 D 4 8 17,0 402 4 D 8 16 19,9 572 4 D 14 28 23,6 821 The cable is designed for long distance telecommunications alongside railway lines. Conductor: Insulation: Colour code: Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire 0,8 mm PE a core: GY - OG b core: WH - YE - BK - GN - BU - BN - RD c core: VT d core: BU - BN - RD - WH - YE - BK - GN cores twisted to quads, quads stranded together to concentric layers filled with petrolat, wrapping with tape, one tinnend copper wire, wrapping with tape; PE, transparent two layers steel tape, filled with petrolat, wrapping with tape PE, black <meter> - "SNCF" - type - "2329" - "ed0"- PENGG KABEL - year of production Technical Details (at 20 C) Standard: SNCF CT AFT N 2329 Ed.0 Conductor diameter: 0,8 mm Conductor resistance: 36,7 Ω/km Insulation resistance: 15 GΩkm Mutual capacitance (at f=800hz): 50 nf/km max: 54 nf/km min: 46 nf/km Capacitance unbalance: k 1 40 pf/300m max 200 pf/300m k 9-12 15 pf/300m max 75 pf/300m e a1/2 130 pf/300m max 1600 pf/300m conductor/conductor 1500 V/DC/1min conductor/shield 3000 V/DC/1min conductor/shield 3750 V/DC/3sek French Railways (SNCF) Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 63

French Railways Note 64 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Swiss Railways, SBB PE4-ALT-CLT...x4x... page 66 Sw-Kabel...x4x... CLT page 67 PE-ALT-CLT 1x4x1,53 page 68 Swiss Railways (SBB) Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 65

Swiss Railways Foam-skin PE insulated, star-quads, with rodent protection PE4-ALT-CLT...x4x C40 mutual capacity 2-200 number of double cores 0,8 1,0 dimension of conductor filling cable elements overall shield, armouring conductor diameter 0,8 mm conductor diameter 1,0 mm Type number of outer diameter weight outer diameter weight double cores approx. mm approx. kg/km approx. mm approx. kg/km PE4-ALT-CLT 1x4x.. 2 14,6 200 - - PE4-ALT-CLT 3x4x.. 6 18,5 340 - - PE4-ALT-CLT 5x4x.. 10 21,8 440 20,8 541 PE4-ALT-CLT 10x4x.. 20 23,0 635 26,3 923 PE4-ALT-CLT 20x4x.. 40 28,8 974 30,8 1241 PE4-ALT-CLT 30x4x.. 60 31,1 1224 36,7 1872 PE4-ALT-CLT 50x4x.. 100 37,4 1790 53,5 2250 The cable is desigend for general use in railway telecommunication systems. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire 0,8 / 1,0 mm foam-skin PE (PE4) a core: WH b core: OG - GN - BN - GY c core: TQ d core: VT cores twisted to quads, quads stranded together in concentric layer, wrapping with tape one or two drain wires; aluminium laminated PEsheath, black (ALT) two layers galvanized steel tape (CL) PE, black (T) PENGG KABEL - year of procution - type - order number - "=>" (arrow from the red end) - <meter> Technical Details (at 20 C) Standard: SBB I-PS 3001.52.1000 Conductor diameter: 0,8 1,0 mm Loop resistance: 73,5 47,0 Ω/km Insulation resistance: 10 10 GΩkm Mutual capacitance: 40 40 nf/km Capacitance unbalance: k 1 100% 380 380 pf/km abs 65 65 pf/km k 9-12 200 200 pf/km abs 35 35 pf/km e a1/2 640 640 pf/km abs 100 100 pf/km conductor/conductor 2000 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Temperatur range: during installation -5 to +50 C 66 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Swiss Railways PE insulated, star-quads, with rodent protection Sw-Kabel x4x CLT mutual capacity 2-60 number of double cores 1,5 2,2 dimension of conductor filling cable elements overall shield, armouring conductor diameter 1,5 mm conductor diameter 2,2 mm Type number of outer diameter weight outer diameter weight double cores approx. mm approx. kg/km approx. mm approx. kg/km Sw-Kabel 1x4x... CLT 2 15,5 223 16,5 342 Sw-Kabel 3x4x... CLT 6 23,5 558 28,0 930 Sw-Kabel 5x4x... CLT 10 28,5 785 33,5 1380 Sw-Kabel 10x4x... CLT 20 36,0 1388 44,5 2560 Sw-Kabel 15x4x... CLT 30 41,0 1946 51,5 3630 Sw-Kabel 20x4x... CLT 40 46,5 2533 58,5 4780 Sw-Kabel 25x4x... CLT 50 52,5 3150 66,5 5850 Sw-Kabel 30x4x... CLT 60 55,0 3557 68,0 6363 The cable is designed for general use in protection systems with an operating voltage 500 Veff (16 2/3 Hz) or 800 V DC. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire 1,5 / 2,2 mm PE a core: WH b core: OR - GN - BN - GY c core: TQ d core: VT cores twisted to quads, quads stranded together in concentric layers, wrapping with tape PE, black two layers galvanized steel tape (CL) PE, black (T) SIGNAL - "=>" (arrow from the red end) - PENGG KABEL - year of production - order number - <meter> Technical Details (at 20 C) Standard: SBB I-PS 3001.82.1000 Conductor diameter: 1,5 2,2 mm Loop resistance: 20,9 10,0 Ω/km Insulation resistance: 10 10 GΩkm Mutual capacitance: 52 60 nf/km Capacitance unbalance: k 1 400 400 pf/km k 9-12 400 400 pf/km e a1/2 650 650 pf/km conductor/conductor 2000 V/50Hz/1min conductor/shield 4000 V/50Hz/1min Swiss Railways (SBB) Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 67

Swiss Railways PE insulated, star-quads, with inductive protection PE-ALT-CLT 1x4x1,53mm C42 mutual capacity 2 number of double cores 1,53 dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km PE-ALT-CLT 1x4x1,53 2 15,2 292 The cable is designed for the connection of ETCS-Balisen. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire 1,53 mm PE (PE) a core: WH b core: OR c core: TQ d core: VT cores twisted to a quad, wrapping with tape two drain wires; aluminium laminated PE-sheath, black (ALT) two layers galvanized steel tape (CL) PE, black (T) SIGNAL - PENGG KABEL - year of prodcution - type - order number - <meter> Technical Details (at 20 C) Standard: SBB I-PS 3001.52.2000 Conductor diameter: 1,53 mm Loop resistance: 19,8 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: max 48,6 nf/km min 35,9 nf/km Attenuation: 1,8 MHz 0,8 db/100m Impedance: 1,8 MHz 120+/-5% Ω Capacitance unbalance: k 1 240 pf/km e a1/2 640 pf/km conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Temperature range: during installation -5 to +50 C 68 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Hungarian Railways, MAV AJ-02YSF(L)2YD2Y...x4x0,8 (HvrQ) page 70 AJ-2Y(L)2YLB2Y...x... (BRQA) page 71 Hungarian Railways (SBB) Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 69

Hungarian Railway Cables PE-foam skin insulated, star quads, with inductive protection AJ-02YSF(L)2YD2Y x4x0,8 (HvrQ) C42 mutual capacity 2-200 number of double cores 0,8 dimension of conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km AJ-02YSF(L)2YD2Y 1x4x0,8 (HvrQ) 2 15,0 350 AJ-02YSF(L)2YD2Y 5x4x0,8 (HvrQ) 10 21,0 690 AJ-02YSF(L)2YD2Y 10x4x0,8 (HvrQ) 20 27,0 1040 AJ-02YSF(L)2YD2Y 15x4x0,8 (HvrQ) 30 29,0 1210 AJ-02YSF(L)2YD2Y 25x4x0,8 (HvrQ) 50 36,0 1630 AJ-02YSF(L)2YD2Y 50x4x0,8 (HvrQ) 100 45,0 2510 AJ-02YSF(L)2YD2Y 75x4x0,8 (HvrQ) 150 54,0 3520 AJ-02YSF(L)2YD2Y 100x4x0,8 (HvrQ) 200 61,0 4420 The cable is designed for underground laying and drawing into conduits for local networks. Conductor: Insulation: Colour code : Cable make up: Filling: Sheath: Screening: Protective cover: solid, bare copper wire 0,8 mm PE foam skin (02YS) a core: RD - GN - YE - BU - BN b core: WT c core: BK d core: GY cores twisted to quads, 5 quads cabled together to basic strands, basic strands cabeld together in concentric layer ( 50 quads); for cables 75 quads, 5 basic strands cabeld together to primary strands and cabeld together in concentric layers filled with petrol jelly (F), wrapping with tape aluminium laminated PE-sheath, black ((L)2Y) 1 layer copper wires ( 1,4 mm) (D), wrapping with tape PE, black (2Y) Technical Details (at 20 C) Standard: costumer specification MAV P-2518/2002 Conductor diameter: 0,8 mm Loop resistance: 73,2 Ω/km Insulation resistance: 5 GΩkm Mutual capacitance: 42 nf/km Capacitance unbalance: k 1 100% 800 pf/300m 50% 400 pf/300m k 9-12 100% 300 pf/300m 50% 400 pf/300m e a1/2 100% 800 pf/300m conductor/conductor 500 V/50Hz/2min conductor/shield 2000 V/50Hz/2min Temperature range: during installation: -5 to +70 C during operation: -30 to +70 C MÀV ZRt. - handset symbol - <meter> - type - PENGG KABEL - year of procution - CE - order number 70 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Hungarian Railway Cables PE-insulated, single core, with rodent protection AJ-2Y(L)2YLB2Y x (BRQA) mutual capacity 2-91 number of cores 1,0 1,5 dimension of conductor filling cable elements overall shield, armouring conductor diameter 1,0 mm conductor diameter 1,5 m Type number of outer diameter weight outer diameter weight cores approx. mm approx. kg/km approx. mm approx. kg/km AJ-2Y(L)2YLB2Y 2x... 2 12,0 250 14,2 310 AJ-2Y(L)2YLB2Y 4x... 4 15,5 362 17,1 443 AJ-2Y(L)2YLB2Y 7x... 7 16,8 432 18,6 547 AJ-2Y(L)2YLB2Y 10x... 10 18,7 515 21,1 676 AJ-2Y(L)2YLB2Y 14x... 14 19,5 590 22,1 782 AJ-2Y(L)2YLB2Y 21x... 21 21,5 821 25,6 1170 AJ-2Y(L)2YLB2Y 30x... 30 24,5 1023 28,3 1451 AJ-2Y(L)2YLB2Y 37x... 37 25,6 1129 29,8 1645 AJ-2Y(L)2YLB2Y 48x... 48 27,8 1322 32,7 1943 AJ-2Y(L)2YLB2Y 61x... 61 29,4 1507 35,2 2338 AJ-2Y(L)2YLB2Y 75x... 75 31,6 1726 38,1 2709 AJ-2Y(L)2YLB2Y 91x... 91 33,3 1944 40,2 3099 The cable is designed for connection of Station signal-safty equipments. Cables can be burried directly into ground or can be laid in cable ducts, tubes and indoor. Conductor: solid, bare copper wire 1,0 / 1,5 mm Insulation: PE (2Y) Colour code : beginning core: red pilot core: blue other cores: nature or black Cable make up: cores are stranded in concentric layers; neighbouring layers must be stranded in opposite direction, wrapping with tape Sheath: aluminium laminated PE-sheath, black ((L)2Y) Screening: one layer aluminium tape (L) Armouring: two layer galvanized steel tape (B) Protective cover: PE, black (2Y) Technical Details (at 20 C) Standard: P-12440/2002 + techn. Changes 19.12.06 Conductor diameter: 1,0 1,5 mm Conductor resistance: 23,39 10,03 Ω/km Insulation resistance: 10 10 GΩkm Reduction factor: P-12440/2002 + techn. Changes 19.12.06 conductor/conductor 2000 V/50Hz/2min conductor/screening 2000 V/50Hz/2min Hungarian Railways (SBB) PENGG KABEL - year of production - type - MAV Zrt. - <meter> - CE - order number Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 71

Hungarian Railway Cables Note 72 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Slovenian Railways, SZ SPZ...x... page 74 Slovenian Railways (SZ) Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 73

Slovenian Railways PVC insulated, single core, with rodent protection SPZ x mutual capacity 2-133 number of cores 0,9 1,4 dimension of conductor filling cable elements overall shield, armouring conductor diameter 0,9 mm conductor diameter 1.4 mm Type number of outer diameter weight outer diameter weight cores approx mm approx. kg/km approx. mm approx. kg/km SPZ 4 x... 4 12,0 210 13,9 294 SPZ 5 x... 5 12,2 218 14,6 322 SPZ 8 x... 8 13,1 256 15,9 402 SPZ 10 x... 10 14,6 326 17,4 488 SPZ 12 x... 12 14,9 350 17,8 535 SPZ 16 x... 16 16,0 408 20,1 691 SPZ 21 x... 21 16,8 471 20,4 771 SPZ 24 x... 24 18,4 530 24,2 965 SPZ 27 x... 27 19,5 611 24,6 1032 SPZ 33 x... 33 19,8 639 26,0 1180 SPZ 40 x... 40 22,1 794 27,0 1263 SPZ 48 x... 48 23,7 898 30,2 1592 SPZ 61 x... 61 25,3 1054 32,4 1896 SPZ 80 x... 80 28,0 1282 35,7 2305 SPZ 108 x... 108 31,7 1636 41,8 3116 SPZ 133 x... 133 35,1 2028 45,6 3799 The cable is designed for connection of Station signal-safety equipments on electrified main railways single-phase system of 25 kv, 50 Hz and D.C. system of 3 kv. Cables can be burried directly into ground or can be laid in cable ducts, tubes and indoor. Conctructions with different Number of wires are also allowed in acc. to agreement with producer and buyer. Conductor: solid, bare copper wire 0,9 / 1,4 mm Insulation: PVC (P) Colour code : starting wire in outer layer : red starting wire in other layers : blue all other wires: grey Cable make up: cores are stranded in concentric layers; Neighbouring layers must be stranded in opposite direction, wrapping with tape Sheath: PVC, black Armouring: one layer galvanized steel tape (Z) Protective cover: PVC, black Technical Details (at 20 C) Standard: JZS S2.011 / 2009 Conductor diameter: 0,9 1,4 mm Conductor resistance: 28,9 11,9 Ω/km Insulation resistance: 5 5 Ωkm Mutual capacitance: 180 210 nf/km Dielectric strength (cond./cond.) 2000 2000 V/50Hz/1min Temperature range: during installation -5 to +70 C during operation up to +60 C <meter> - type- JZS S2.011 - PENGG KABEL 74 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Fiber Optic Cables A-DF(ZN)2Y page 76 A-DF(ZN)2Y4Y page 78 A-DF(ZN)2Y(SR)2Y page 80 A-DQ(ZN)2Y(HD) ADSS 6kN page 82 A-D2Y(ZN)2Y ADSS 6kN page 84 A-DQ(ZN)2Y (HD) Minicable page 86 Fiber Data Sheet - Singlemodefiber E9 page 88 Fiber Data Sheet - Low Bend Sensitive Singlemodefiber E9 page 89 Fiber Data Sheet - NZDF-Singlemodefiber E8 page 90 Fiber Data Sheet - NZDF-Singlemodefiber E8 page 91 Fiber Data Sheet - Multimodefiber OM2 G50 page 92 Fiber Data Sheet - Multimodefiber OM3 (OM3+, OM4) G50 page 93 Fiber Data Sheet - Multimodefiber G62,5 page 94 Letter Symbols - Fiber Optics page 95 Colour Codes - Fiber Optics page 96 Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 75

Fiber Optical Outdoor Cables - Standard Design Outdoor Cable, filled, loose tube construction A-DF(ZN)2Y Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-DF(ZN)2Y 1 + 5 2 (4) 2 (4) 2,0 1500 75 9,5 A-DF(ZN)2Y 2 + 4 2 (4) 4 (8) 2,0 1500 75 9,5 A-DF(ZN)2Y 3 + 3 2 (4) 6 (12) 2,0 1500 75 9,5 A-DF(ZN)2Y 4 + 2 2 (4) 8 (16) 2,0 1500 75 9,5 A-DF(ZN)2Y 5 + 1 2 (4) 10 (20) 2,0 1500 75 9,5 A-DF(ZN)2Y 6 + 0 2 (4) 12 (24) 2,0 1500 75 9,5 A-DF(ZN)2Y 1 + 4 6 6 2,8 1500 95 11,0 A-DF(ZN)2Y 2 + 3 6 12 2,8 1500 95 11,0 A-DF(ZN)2Y 3 + 2 6 18 2,8 1500 95 11,0 A-DF(ZN)2Y 4 + 1 6 24 2,8 1500 95 11,0 A-DF(ZN)2Y 5 + 0 6 30 2,8 1500 95 11,0 A-DF(ZN)2Y 6 + 0 6 36 2,8 1500 120 12,0 A-DF(ZN)2Y 1 + 4 8 8 2,8 1500 95 11,0 A-DF(ZN)2Y 2 + 3 8 16 2,8 1500 95 11,0 A-DF(ZN)2Y 3 + 2 8 24 2,8 1500 95 11,0 A-DF(ZN)2Y 4 + 1 8 32 2,8 1500 95 11,0 A-DF(ZN)2Y 5 + 0 8 40 2,8 1500 95 11,0 A-DF(ZN)2Y 6 + 0 8 48 2,8 1500 120 12,0 A-DF(ZN)2Y 1 + 4 12 12 2,8 1500 95 11,0 A-DF(ZN)2Y 2 + 3 12 24 2,8 1500 95 11,0 A-DF(ZN)2Y 3 + 2 12 36 2,8 1500 95 11,0 A-DF(ZN)2Y 4 + 1 12 48 2,8 1500 95 11,0 A-DF(ZN)2Y 5 + 0 12 60 2,8 1500 95 11,0 A-DF(ZN)2Y 6 + 0 12 72 2,8 1500 120 12,0 A-DF(ZN)2Y 8 + 0 12 96 2,8 2000 145 13,7 A-DF(ZN)2Y 10 + 0 12 120 2,8 2000 185 15,5 A-DF(ZN)2Y 12 + 0 12 144 2,8 3000 235 17,3 A-DF(ZN)2Y 16 + 0 12 192 2,8 3000 215 16,7 A-DF(ZN)2Y 18 + 0 12 216 2,8 3000 245 17,7 A-DF(ZN)2Y 4 + 1 24 96 2,8 1500 95 11,0 A-DF(ZN)2Y 5 + 0 24 120 2,8 1500 95 11,0 A-DF(ZN)2Y 6 + 0 24 144 2,8 1500 125 12,0 A-DF(ZN)2Y 8 + 0 24 192 2,8 2000 150 13,7 A-DF(ZN)2Y 10 + 0 24 240 2,8 2000 195 15,5 A-DF(ZN)2Y 12 + 0 24 288 2,8 3000 245 17,3 A-DF(ZN)2Y 16 + 0 24 384 2,8 3000 230 16,7 A-DF(ZN)2Y 18 + 0 24 432 2,8 3000 260 17,7 76 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-DF(ZN)2Y 1 + 4 6 6 2,3 1500 80 10,0 A-DF(ZN)2Y 2 + 3 6 12 2,3 1500 80 10,0 A-DF(ZN)2Y 3 + 2 6 18 2,3 1500 80 10,0 A-DF(ZN)2Y 4 + 1 6 24 2,3 1500 80 10,0 A-DF(ZN)2Y 5 + 0 6 30 2,3 1500 80 10,0 A-DF(ZN)2Y 6 + 0 6 36 2,3 1500 95 10,5 A-DF(ZN)2Y 1 + 4 8 8 2,3 1500 80 10,0 A-DF(ZN)2Y 2 + 3 8 16 2,3 1500 80 10,0 A-DF(ZN)2Y 3 + 2 8 24 2,3 1500 80 10,0 A-DF(ZN)2Y 4 + 1 8 32 2,3 1500 80 10,0 A-DF(ZN)2Y 5 + 0 8 40 2,3 1500 80 10,0 A-DF(ZN)2Y 6 + 0 8 48 2,3 1500 95 10,5 A-DF(ZN)2Y 1 + 4 12 12 2,3 1500 89 10,0 A-DF(ZN)2Y 2 + 3 12 24 2,3 1500 89 10,0 A-DF(ZN)2Y 3 + 2 12 36 2,3 1500 89 10,0 A-DF(ZN)2Y 4 + 1 12 48 2,3 1500 89 10,0 A-DF(ZN)2Y 5 + 0 12 60 2,3 1500 89 10,0 A-DF(ZN)2Y 6 + 0 12 72 2,3 1500 95 10,5 A-DF(ZN)2Y 8 + 0 12 96 2,3 2000 115 12,0 A-DF(ZN)2Y 10 + 0 12 120 2,3 2000 145 13,3 A-DF(ZN)2Y 12 + 0 12 144 2,3 3000 185 15,0 A-DF(ZN)2Y 16 + 0 12 192 2,3 3000 165 14,5 A-DF(ZN)2Y 18 + 0 12 216 2,3 3000 185 15,0 For telecommunication and information systems. FRP-central element loose tubes, SZ-cabling (if necessary with fillers) jelly filled cable core strength members (aramide yarns) PE-sheath, UV-resistant, black Fiber colours red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink Tube colours counter core red, others yellow (E9), green (G50) or blue (G62,5) Note longitudinally water-tight On request other number of tubes increased tensile strength reinforced outer sheath (2YV) other sheath colours coloured stripes HDPE or LDPE sheath other tube and fiber colours Laying usable for fixed laying in earth, ducts or conduits and outdoors double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing other markings on request Technical Data tensile strength according to IEC 794-1-E1 according to EN 187 000-501 value: Please have a look at the relevant chart. compressive strength according to IEC 794-1-E3 (crush) according to EN 187 000-504 value: 2500 N/10 cm impact according to IEC 794-1-E4 according to EN 187 000-505 value: 25 Nm torsion according to IEC 794-1-E7 according to EN 187 000-508 value: 5 cycles ±1 turn kink, cable according to IEC 794-1-E10 according to EN 187 000-511 value: The cables do not form a kink when a loop is drawn together to a diameter 12 times the cable nominal diameter. kink, loose tube according to IEC 794-1-E16 according to EN 187 000-512 value: The loose tubes do not kink. min. bending radius according to IEC 794-1-E11 according to EN 187 000-513 value: R = 20 x D (cable outer diameter) temperature range according to IEC 794-1-F1 according to EN 187 000-601 storage and transport: -40 C to +70 C laying: -5 C to +60 C operation: -30 C to +70 C water penetration according to IEC 794-1-F5 according to EN 187 000-605 No water on free end. Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 77

Fiber Optical Outdoor Cables - Standard Design Outdoor Cable, filled, loose tube construction, metal-free rodent protection A-DF(ZN)2Y4Y Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-DF(ZN)2Y4Y 1 + 5 2 (4) 2 (4) 2,0 1500 90 10,5 A-DF(ZN)2Y4Y 2 + 4 2 (4) 4 (8) 2,0 1500 90 10,5 A-DF(ZN)2Y4Y 3 + 3 2 (4) 6 (12) 2,0 1500 90 10,5 A-DF(ZN)2Y4Y 4 + 2 2 (4) 8 (16) 2,0 1500 90 10,5 A-DF(ZN)2Y4Y 5 + 1 2 (4) 10 (20) 2,0 1500 90 10,5 A-DF(ZN)2Y4Y 6 + 0 2 (4) 12 (24) 2,0 1500 90 10,5 A-DF(ZN)2Y4Y 1 + 4 6 6 2,8 1500 115 12,0 A-DF(ZN)2Y4Y 2 + 3 6 12 2,8 1500 115 12,0 A-DF(ZN)2Y4Y 3 + 2 6 18 2,8 1500 115 12,0 A-DF(ZN)2Y4Y 4 + 1 6 24 2,8 1500 115 12,0 A-DF(ZN)2Y4Y 5 + 0 6 30 2,8 1500 115 12,0 A-DF(ZN)2Y4Y 6 + 0 6 36 2,8 1500 134 13,0 A-DF(ZN)2Y4Y 1 + 4 8 8 2,8 1500 115 12,0 A-DF(ZN)2Y4Y 2 + 3 8 16 2,8 1500 115 12,0 A-DF(ZN)2Y4Y 3 + 2 8 24 2,8 1500 115 12,0 A-DF(ZN)2Y4Y 4 + 1 8 32 2,8 1500 115 12,0 A-DF(ZN)2Y4Y 5 + 0 8 40 2,8 1500 115 12,0 A-DF(ZN)2Y4Y 6 + 0 8 48 2,8 1500 135 13,0 A-DF(ZN)2Y4Y 1 + 4 12 12 2,8 1500 115 12,0 A-DF(ZN)2Y4Y 2 + 3 12 24 2,8 1500 115 12,0 A-DF(ZN)2Y4Y 3 + 2 12 36 2,8 1500 115 12,0 A-DF(ZN)2Y4Y 4 + 1 12 48 2,8 1500 115 12,0 A-DF(ZN)2Y4Y 5 + 0 12 60 2,8 1500 115 12,0 A-DF(ZN)2Y4Y 6 + 0 12 72 2,8 1500 136 13,0 A-DF(ZN)2Y4Y 8 + 0 12 96 2,8 2000 170 14,7 A-DF(ZN)2Y4Y 10 + 0 12 120 2,8 2000 210 16,5 A-DF(ZN)2Y4Y 12 + 0 12 144 2,8 3000 265 18,3 A-DF(ZN)2Y4Y 16 + 0 12 192 2,8 3000 240 17,7 A-DF(ZN)2Y4Y 18 + 0 12 216 2,8 3000 275 18,7 A-DF(ZN)2Y4Y 4 + 1 24 96 2,8 1500 120 12,0 A-DF(ZN)2Y4Y 5 + 0 24 120 2,8 1500 120 12,0 A-DF(ZN)2Y4Y 6 + 0 24 144 2,8 1500 145 13,0 A-DF(ZN)2Y4Y 8 + 0 24 192 2,8 2000 175 14,7 A-DF(ZN)2Y4Y 10 + 0 24 240 2,8 2000 220 16,5 A-DF(ZN)2Y4Y 12 + 0 24 288 2,8 3000 275 18,3 A-DF(ZN)2Y4Y 16 + 0 24 384 2,8 3000 255 17,7 A-DF(ZN)2Y4Y 18 + 0 24 432 2,8 3000 290 18,7 78 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-DF(ZN)2Y4Y 1 + 4 6 6 2,3 1500 95 11,0 A-DF(ZN)2Y4Y 2 + 3 6 12 2,3 1500 95 11,0 A-DF(ZN)2Y4Y 3 + 2 6 18 2,3 1500 95 11,0 A-DF(ZN)2Y4Y 4 + 1 6 24 2,3 1500 95 11,0 A-DF(ZN)2Y4Y 5 + 0 6 30 2,3 1500 95 11,0 A-DF(ZN)2Y4Y 6 + 0 6 36 2,3 1500 110 11,5 A-DF(ZN)2Y4Y 1 + 4 8 8 2,3 1500 95 11,0 A-DF(ZN)2Y4Y 2 + 3 8 16 2,3 1500 95 11,0 A-DF(ZN)2Y4Y 3 + 2 8 24 2,3 1500 95 11,0 A-DF(ZN)2Y4Y 4 + 1 8 32 2,3 1500 95 11,0 A-DF(ZN)2Y4Y 5 + 0 8 40 2,3 1500 95 11,0 A-DF(ZN)2Y4Y 6 + 0 8 48 2,3 1500 110 11,5 A-DF(ZN)2Y4Y 1 + 4 12 12 2,3 1500 95 11,0 A-DF(ZN)2Y4Y 2 + 3 12 24 2,3 1500 95 11,0 A-DF(ZN)2Y4Y 3 + 2 12 36 2,3 1500 95 11,0 A-DF(ZN)2Y4Y 4 + 1 12 48 2,3 1500 95 11,0 A-DF(ZN)2Y4Y 5 + 0 12 60 2,3 1500 95 11,0 A-DF(ZN)2Y4Y 6 + 0 12 72 2,3 1500 110 11,5 A-DF(ZN)2Y4Y 8 + 0 12 96 2,3 2000 135 13,0 A-DF(ZN)2Y4Y 10 + 0 12 120 2,3 2000 165 14,4 A-DF(ZN)2Y4Y 12 + 0 12 144 2,3 3000 210 16,0 A-DF(ZN)2Y4Y 16 + 0 12 192 2,3 3000 190 15,5 A-DF(ZN)2Y4Y 18 + 0 12 216 2,3 3000 210 16,0 For telecommunication and information systems. FRP-central element loose tubes, SZ-cabling (if necessary with fillers) filling of cable core strength members (aramide yarns) PE-sheath, UV-resistant, black PA-protective cover, UV-resistant, transparent Fiber colours red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink Tube colours counter core red, others yellow (E9), green (G50) or blue (G62,5) Note longitudinally water-tight On request other number of tubes increased tensile strength other sheath colours coloured stripes HDPE or LDPE sheath other tube and fiber colours Laying usable for fixed laying in earth, ducts or conduits and outdoors double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing other markings on request Technical Data tensile strength according to IEC 794-1-E1 according to EN 187 000-501 value: Please have a look at the relevant chart. compressive strength according to IEC 794-1-E3 (crush) according to EN 187 000-504 value: 3000 N/10 cm impact according to IEC 794-1-E4 according to EN 187 000-505 value: 25 Nm torsion according to IEC 794-1-E7 according to EN 187 000-508 value: 5 cycles ±1 turn kink, cable according to IEC 794-1-E10 according to EN 187 000-511 value: The cables do not form a kink when a loop is drawn together to a diameter 12 times the cable nominal diameter. kink, loose tube according to IEC 794-1-E16 according to EN 187 000-512 value: The loose tubes do not kink. min. bending radius according to IEC 794-1-E11 according to EN 187 000-513 value: R = 20 x D (cable outer diameter) temperature range according to IEC 794-1-F1 according to EN 187 000-601 storage and transport: -40 C to +70 C laying: -5 C to +60 C operation: -30 C to +70 C water penetration according to IEC 794-1-F5 according to EN 187 000-605 No water on free end. Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 79

Fiber Optical Outdoor Cables - Standard Design Outdoor Cable, filled, loose tube construction, metallic rodent protection A-DF(ZN)2Y(SR)2Y Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-DF(ZN)2Y(SR)2Y 1 + 5 2 (4) 2 (4) 2,0 2000 180 14,0 A-DF(ZN)2Y(SR)2Y 2 + 4 2 (4) 4 (8) 2,0 2000 180 14,0 A-DF(ZN)2Y(SR)2Y 3 + 3 2 (4) 6 (12) 2,0 2000 180 14,0 A-DF(ZN)2Y(SR)2Y 4 + 2 2 (4) 8 (16) 2,0 2000 180 14,0 A-DF(ZN)2Y(SR)2Y 5 + 1 2 (4) 10 (20) 2,0 2000 180 14,0 A-DF(ZN)2Y(SR)2Y 6 + 0 2 (4) 12 (24) 2,0 2000 180 14,0 A-DF(ZN)2Y(SR)2Y 1 + 4 6 6 2,8 2500 220 15,5 A-DF(ZN)2Y(SR)2Y 2 + 3 6 12 2,8 2500 220 15,5 A-DF(ZN)2Y(SR)2Y 3 + 2 6 18 2,8 2500 220 15,5 A-DF(ZN)2Y(SR)2Y 4 + 1 6 24 2,8 2500 220 15,5 A-DF(ZN)2Y(SR)2Y 5 + 0 6 30 2,8 2500 220 15,5 A-DF(ZN)2Y(SR)2Y 6 + 0 6 36 2,8 3000 250 16,5 A-DF(ZN)2Y(SR)2Y 1 + 4 8 8 2,8 2500 220 15,5 A-DF(ZN)2Y(SR)2Y 2 + 3 8 16 2,8 2500 220 15,5 A-DF(ZN)2Y(SR)2Y 3 + 2 8 24 2,8 2500 220 15,5 A-DF(ZN)2Y(SR)2Y 4 + 1 8 32 2,8 2500 220 15,5 A-DF(ZN)2Y(SR)2Y 5 + 0 8 40 2,8 2500 220 15,5 A-DF(ZN)2Y(SR)2Y 6 + 0 8 48 2,8 3000 250 16,5 A-DF(ZN)2Y(SR)2Y 1 + 4 12 12 2,8 2500 220 15,5 A-DF(ZN)2Y(SR)2Y 2 + 3 12 24 2,8 2500 220 15,5 A-DF(ZN)2Y(SR)2Y 3 + 2 12 36 2,8 2500 220 15,5 A-DF(ZN)2Y(SR)2Y 4 + 1 12 48 2,8 2500 220 15,5 A-DF(ZN)2Y(SR)2Y 5 + 0 12 60 2,8 2500 220 15,5 A-DF(ZN)2Y(SR)2Y 6 + 0 12 72 2,8 3000 250 16,5 A-DF(ZN)2Y(SR)2Y 8 + 0 12 96 2,8 3500 290 18,0 A-DF(ZN)2Y(SR)2Y 10 + 0 12 120 2,8 4000 345 20,0 A-DF(ZN)2Y(SR)2Y 12 + 0 12 144 2,8 4500 410 21,7 80 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-DF(ZN)2Y(SR)2Y 1 + 4 6 6 2,3 2500 195 14,2 A-DF(ZN)2Y(SR)2Y 2 + 3 6 12 2,3 2500 195 14,2 A-DF(ZN)2Y(SR)2Y 3 + 2 6 18 2,3 2500 195 14,2 A-DF(ZN)2Y(SR)2Y 4 + 1 6 24 2,3 2500 195 14,2 A-DF(ZN)2Y(SR)2Y 5 + 0 6 30 2,3 2500 195 14,2 A-DF(ZN)2Y(SR)2Y 6 + 0 6 36 2,3 3000 215 15,0 A-DF(ZN)2Y(SR)2Y 1 + 4 8 8 2,3 2500 195 14,2 A-DF(ZN)2Y(SR)2Y 2 + 3 8 16 2,3 2500 195 14,2 A-DF(ZN)2Y(SR)2Y 3 + 2 8 24 2,3 2500 195 14,2 A-DF(ZN)2Y(SR)2Y 4 + 1 8 32 2,3 2500 195 14,2 A-DF(ZN)2Y(SR)2Y 5 + 0 8 40 2,3 2500 195 14,2 A-DF(ZN)2Y(SR)2Y 6 + 0 8 48 2,3 3000 215 15,0 A-DF(ZN)2Y(SR)2Y 1 + 4 12 12 2,3 2500 195 14,2 A-DF(ZN)2Y(SR)2Y 2 + 3 12 24 2,3 2500 195 14,2 A-DF(ZN)2Y(SR)2Y 3 + 2 12 36 2,3 2500 195 14,2 A-DF(ZN)2Y(SR)2Y 4 + 1 12 48 2,3 2500 195 14,2 A-DF(ZN)2Y(SR)2Y 5 + 0 12 60 2,3 2500 195 14,2 A-DF(ZN)2Y(SR)2Y 6 + 0 12 72 2,3 3000 215 15,0 A-DF(ZN)2Y(SR)2Y 8 + 0 12 96 2,3 3500 245 16,2 A-DF(ZN)2Y(SR)2Y 10 + 0 12 120 2,3 4000 290 17,7 A-DF(ZN)2Y(SR)2Y 12 + 0 12 144 2,3 4500 345 19,5 For telecommunication and information systems. FRP-central element loose tubes, SZ-cabling (if necessary with fillers) jelly filled cable core strength members (aramide yarns) PE-inner sheath corrugated steel tape, laminated PE-outer sheath, UV-resistant, black Fiber colours red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink Tube colours counter core red, others yellow (E9), green (G50) or blue (G62,5) Note longitudinally water-tight On request other number of fibers (max. 432) other number of tubes increased tensile strength reinforced outer sheath (2YV) other sheath colours coloured stripes HDPE or LDPE sheath other tube and fiber colours dry filled version Laying usable for fixed laying in earth, ducts or conduits and outdoors double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing other markings on request Technical Data tensile strength according to IEC 794-1-E1 according to EN 187 000-501 value: Please have a look at the relevant chart. compressive strength according to IEC 794-1-E3 (crush) according to EN 187 000-504 value: 3000 N/10 cm impact according to IEC 794-1-E4 according to EN 187 000-505 value: 25 Nm torsion according to IEC 794-1-E7 according to EN 187 000-508 value: 5 cycles ±1 turn kink, cable according to IEC 794-1-E10 according to EN 187 000-511 value: The cables do not form a kink when a loop is drawn together to a diameter 12 times the cable nominal diameter. kink, loose tube according to IEC 794-1-E16 according to EN 187 000-512 value: The loose tubes do not kink. min. bending radius according to IEC 794-1-E11 according to EN 187 000-513 value: R = 20 x D (cable outer diameter) temperature range according to IEC 794-1-F1 according to EN 187 000-601 storage and transport: -40 C to +70 C laying: -5 C to +60 C operation: -30 C to +70 C water penetration according to IEC 794-1-F5 according to EN 187 000-605 No water on free end. Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 81

All-Dielectric-Self-Supporting Cables (ADSS) Aerial Cable, single sheath, loose tube construction, metal-free A-DQ(ZN)2Y(HD)... 6kN Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-DQ(ZN)2Y 1 + 5 2 (4) 2 (4) 2,3 6.000 140 13,0 A-DQ(ZN)2Y 2 + 4 2 (4) 4 (8) 2,3 6.000 140 13,0 A-DQ(ZN)2Y 3 + 3 2 (4) 6 (12) 2,3 6.000 140 13,0 A-DQ(ZN)2Y 4 + 2 2 (4) 8 (16) 2,3 6.000 140 13,0 A-DQ(ZN)2Y 5 + 1 2 (4) 10 (20) 2,3 6.000 140 13,0 A-DQ(ZN)2Y 6 + 0 2 (4) 12 (24) 2,3 6.000 140 13,0 A-DQ(ZN)2Y 1 + 4 6 6 2,8 6.000 145 13,6 A-DQ(ZN)2Y 2 + 3 6 12 2,8 6.000 145 13,6 A-DQ(ZN)2Y 3 + 2 6 18 2,8 6.000 145 13,6 A-DQ(ZN)2Y 4 + 1 6 24 2,8 6.000 145 13,6 A-DQ(ZN)2Y 5 + 0 6 30 2,8 6.000 145 13,6 A-DQ(ZN)2Y 6 + 0 6 36 2,8 6.000 170 14,6 A-DQ(ZN)2Y 1 + 4 8 8 2,8 6.000 145 13,6 A-DQ(ZN)2Y 2 + 3 8 16 2,8 6.000 145 13,6 A-DQ(ZN)2Y 3 + 2 8 24 2,8 6.000 145 13,6 A-DQ(ZN)2Y 4 + 1 8 32 2,8 6.000 145 13,6 A-DQ(ZN)2Y 5 + 0 8 40 2,8 6.000 145 13,6 A-DQ(ZN)2Y 6 + 0 8 48 2,8 6.000 170 14,6 A-DQ(ZN)2Y 1 + 4 12 12 2,8 6.000 145 13,6 A-DQ(ZN)2Y 2 + 3 12 24 2,8 6.000 145 13,6 A-DQ(ZN)2Y 3 + 2 12 36 2,8 6.000 145 13,6 A-DQ(ZN)2Y 4 + 1 12 48 2,8 6.000 145 13,6 A-DQ(ZN)2Y 5 + 0 12 60 2,8 6.000 145 13,6 A-DQ(ZN)2Y 6 + 0 12 72 2,8 6.000 170 14,6 A-DQ(ZN)2Y 8 + 0 12 96 2,8 6.000 200 16,2 A-DQ(ZN)2Y 10 + 0 12 120 2,8 6.000 245 18,0 A-DQ(ZN)2Y 12 + 0 12 144 2,8 6.000 300 19,8 82 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Metal-free aerial cable (ADSS = alldielectric selfsupporting) for telecommunication and information systems. FRP-central element loose tubes, SZ-cabling (if necessary with fillers) strength members (aramide yarns) HDPE-outer sheath, UV-resistant, black Fiber colours red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink Tube colours counter core red, others yellow (E9), green (G50) or blue (G62,5) Note not longitudinally water-tight On request other number of tubes for temperatures down to -60 C other tube and fiber colours Laying usable for fixed laying on selfsupporting lines (up to 60kV) and overhead contact lines, in earth, ducts or conduits and outdoors double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing other markings on request Technical Data tensile strength according to IEC 794-1-E1 according to EN 187 000-501 compressive strength according to IEC 794-1-E3 (crush) according to EN 187 000-504 value: 3000 N/10 cm impact according to IEC 794-1-E4 according to EN 187 000-505 value: 25 Nm torsion according to IEC 794-1-E7 according to EN 187 000-508 value: 5 cycles ±1 turn kink, cable according to IEC 794-1-E10 according to EN 187 000-511 value: The cables do not form a kink when a loop is drawn together to a diameter 12 times the cable nominal diameter. kink, loose tube according to IEC 794-1-E16 according to EN 187 000-512 value: The loose tubes do not kink. temperature range according to IEC 794-1-F1 according to EN 187 000-601 storage and transport: -40 C to +70 C laying: -5 C to +60 C operation: -30 C to +70 C water penetration according to IEC 794-1-F5 according to EN 187 000-605 value: No water on free end. span distance up to 100 m Span distance calculation on request: We need the following parameter values: horinzontal distance from pole to pole:? [m] height difference from pole to pole:? [m] sag in meters or percent to the above mentioned values:? [m-%] ballast or added weight (ice and wind):? [kg/m] Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 83

All-Dielectric-Self-Supporting Cables (ADSS) Aerial Cable, unfilled, loose tube construction, metal-free A-D2Y(ZN)2Y... 6kN Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-D2Y(ZN)2Y 1 + 5 2 (4) 2 (4) 2,3 6.000 135 13,0 A-D2Y(ZN)2Y 2 + 4 2 (4) 4 (8) 2,3 6.000 135 13,0 A-D2Y(ZN)2Y 3 + 3 2 (4) 6 (12) 2,3 6.000 135 13,0 A-D2Y(ZN)2Y 4 + 2 2 (4) 8 (16) 2,3 6.000 135 13,0 A-D2Y(ZN)2Y 5 + 1 2 (4) 10 (20) 2,3 6.000 135 13,0 A-D2Y(ZN)2Y 6 + 0 2 (4) 12 (24) 2,3 6.000 135 13,0 A-D2Y(ZN)2Y 1 + 4 6 6 2,8 6.000 140 14,1 A-D2Y(ZN)2Y 2 + 3 6 12 2,8 6.000 140 14,1 A-D2Y(ZN)2Y 3 + 2 6 18 2,8 6.000 140 14,1 A-D2Y(ZN)2Y 4 + 1 6 24 2,8 6.000 140 14,1 A-D2Y(ZN)2Y 5 + 0 6 30 2,8 6.000 140 14,1 A-D2Y(ZN)2Y 6 + 0 6 36 2,8 6.000 165 14,6 A-D2Y(ZN)2Y 1 + 4 8 8 2,8 6.000 140 14,1 A-D2Y(ZN)2Y 2 + 3 8 16 2,8 6.000 140 14,1 A-D2Y(ZN)2Y 3 + 2 8 24 2,8 6.000 140 14,1 A-D2Y(ZN)2Y 4 + 1 8 32 2,8 6.000 140 14,1 A-D2Y(ZN)2Y 5 + 0 8 40 2,8 6.000 140 14,1 A-D2Y(ZN)2Y 6 + 0 8 48 2,8 6.000 165 14,6 A-D2Y(ZN)2Y 1 + 4 12 12 2,8 6.000 140 14,1 A-D2Y(ZN)2Y 2 + 3 12 24 2,8 6.000 140 14,1 A-D2Y(ZN)2Y 3 + 2 12 36 2,8 6.000 140 14,1 A-D2Y(ZN)2Y 4 + 1 12 48 2,8 6.000 140 14,1 A-D2Y(ZN)2Y 5 + 0 12 60 2,8 6.000 140 14,1 A-D2Y(ZN)2Y 6 + 0 12 72 2,8 6.000 162 14,6 A-D2Y(ZN)2Y 8 + 0 12 96 2,8 6.000 196 16,2 A-D2Y(ZN)2Y 10 + 0 12 120 2,8 6.000 246 18,1 A-D2Y(ZN)2Y 12 + 0 12 144 2,8 6.000 295 20,0 84 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Metal-free aerial cable (ADSS = alldielectric selfsupporting) for telecommunication and information systems. FRP-central element loose tubes, SZ-cabling (if necessary with fillers) dry filled cable core strength members (aramide yarns) HDPE-outer sheath, UV-resistant, black Fiber colours red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink Tube colours counter core red, others yellow (E9), green (G50) or blue (G62,5) Note not longitudinally water-tight On request other number of tubes for temperatures down to -60 C other tube and fiber colours Laying usable for fixed laying on selfsupporting lines (up to 60kV) and overhead contact lines, in earth, ducts or conduits and outdoors double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing other markings on request Technical Data tensile strength according to IEC 794-1-E1 according to EN 187 000-501 compressive strength according to IEC 794-1-E3 (crush) according to EN 187 000-504 value: 3000 N/10 cm impact according to IEC 794-1-E4 according to EN 187 000-505 value: 25 Nm torsion according to IEC 794-1-E7 according to EN 187 000-508 value: 5 cycles ±1 turn kink, cable according to IEC 794-1-E10 according to EN 187 000-511 value: The cables do not form a kink when a loop is drawn together to a diameter 12 times the cable nominal diameter. kink, loose tube according to IEC 794-1-E16 according to EN 187 000-512 value: The loose tubes do not kink. temperature range according to IEC 794-1-F1 according to EN 187 000-601 storage and transport: -40 C to +70 C laying: -5 C to +60 C operation: -30 C to +70 C water penetration according to IEC 794-1-F5 according to EN 187 000-605 value: No water on free end. span distance up to 100 m Span distance calculation on request: We need the following parameter values: horinzontal distance from pole to pole:? [m] height difference from pole to pole:? [m] sag in meters or percent to the above mentioned values:? [m-%] ballast or added weight (ice and wind):? [kg/m] Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 85

Stranded loose tube Mini cable with 4-144 optical fibers Mini Cable, dry filled, loose tube construction, metal-free A-DQ(ZN)2Y (HD) Type number number of tubes tube- tensile strength outer-diameter weight of fibers (fillers) approx. mm max. N approx. mm approx. kg/km A-DQ(ZN)2Y (HD) 1x4 4 1 (5) 1,5 700 5.6 30 A-DQ(ZN)2Y (HD) 1x8 8 1 (5) 1,5 700 5.6 30 A-DQ(ZN)2Y (HD) 1x12 12 1 (5) 1,5 700 5.6 30 A-DQ(ZN)2Y (HD) 2x12 24 2 (4) 1,5 700 5.6 30 A-DQ(ZN)2Y (HD) 3x12 36 3 (3) 1,5 700 5.6 30 A-DQ(ZN)2Y (HD) 4x12 48 4 (2) 1,5 700 5.6 30 A-DQ(ZN)2Y (HD) 5x12 60 5 (1) 1,5 700 5.6 30 A-DQ(ZN)2Y (HD) 6x12 72 6 (0) 1,5 700 5.6 30 A-DQ(ZN)2Y (HD) 8x12 96 8 (0) 1,5 700 6.5 43 A-DQ(ZN)2Y (HD) 12x12 144 12 (0) 1,5 700 8.5 63 A-DQ(ZN)2Y (HD) 1x4 4 1 (5) 1,7 900 6.4 37 A-DQ(ZN)2Y (HD) 1x8 8 1 (5) 1,7 900 6.4 37 A-DQ(ZN)2Y (HD) 1x12 12 1 (5) 1,7 900 6.4 37 A-DQ(ZN)2Y (HD) 2x12 24 2 (4) 1,7 900 6.4 37 A-DQ(ZN)2Y (HD) 3x12 36 3 (3) 1,7 900 6.4 37 A-DQ(ZN)2Y (HD) 4x12 48 4 (2) 1,7 900 6.4 37 A-DQ(ZN)2Y (HD) 5x12 60 5 (1) 1,7 900 6.4 37 A-DQ(ZN)2Y (HD) 6x12 72 6 (0) 1,7 900 6.4 37 A-DQ(ZN)2Y (HD) 8x12 96 8 (0) 1,7 900 7.4 56 A-DQ(ZN)2Y (HD) 12x12 144 12 (0) 1,7 900 10.5 88 A-DQ(ZN)2Y (HD) 6x24 144 6 (0) 2,0 900 8.0 71 Suitable for Metro, Access or FTTx implementations rip cord central member, metal free loose buffer tube filled with a thixotropic gel, swellable aramid yarns dry filled cable core HDPE-sheath, UV-resistant, black Fiber colours blue, orange, green, brown, slate, white, red, black, yellow, violet, pink, turquoise Tube colours up to 12 tubes: blue, orange, green, brown, slate, white, red, black, yellow, violet, pink, turquoise Technical Data Temp. range storage and transport -30 C up to +60 C laying -5 C up to +50 C operation -30 C up to +60 C Crush resistance 900 N/10 cm Impact strength 5 Nm (3 impacts, 300 mm hammer radius) Water penetration 1 m (0.1 bar, 24 h) Bending radius permanent 65 mm during installation 90 mm Filling element colour natural On request other sheath colours other tube and fiber colours Laying for installation in miniduct systems double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing other markings on request 86 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Fiber Optic Cables Note Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 87

Fiber Data Sheet Singlemodefiber (SM) E9 Common fiber type E9/125 Singlemode Fiber standard ITU-T G.652 D; EN188000, EN1888100, EN1888101; VDE 0888/part 102, VDE 0888/part 103, TS 0311/part 3 and TS 0311/part 2 of DTAG fiber decribtion The fiber is ideally designed for use in metropolitan, local and access networks due to its superior specifications - low optical loss aross the entire wavelength range from 1260 to 1625 nm, tightest available geometry, low splice loss and low polarization mode dispersion. Mechanical Properties core diameter d at 1310 nm 9.2 ±0.4 µm at 1550 nm 10.4 ±0.5 µm core concentricity error 0.5 µm cladding diameter 125 ±0.7 µm cladding non-circularity 0.7 % cladding/coating concentricity error 12.0 µm coating non-circularity 6.0 % fiber diameter uncoloured 242 ±5 µm coloured 250 ±10 µm tensile strength according to EN 188000 PV201, 1s 8 N strain level 120 kpsi coating strip force 3.5 N bending radius 30 mm Optical Properties max / typical attenuation at 1310 nm 0.34 / 0.32 db/km at 1383 nm 0.31 / 0.28 db/km at 1490 nm 0.23 / 0.21 db/km at 1550 nm 0.21 / 0.19 db/km at 1625 nm 0.23 / 0.20 db/km attenuation inequality (...) at 1310 and 1550 nm 0.05 db/km attenuation (Makrobending) at 1310 and 1550 nm 0.05 db attenuation alteration (range -60 up to +85 C) at 1310 and 1550 nm 0.05 db/km attenuation for WDM/EÜS at 1550 ±20 nm 0.22 db/km chromatic dispersion at 1285 1330 nm 3 ps/(nm*km) at 1260 1360 nm 12 ps/(nm*km) at 1480 1580 nm 19 ps/(nm*km) polarization mode dipersion (PMD) 0.1 ps/ km PMD Link Design Value acc. IEC 60794/5.5 Method 1 0.06 ps/ km fiber cut-off wavelength (referred to RTM) λ cf -range 1150 1330 nm cable cut-off wavelength λ cff -range 1260 nm point defect at pulse-width 10ns at 1310 and 1550 nm 0.05 db zero dispersion wavelength λ 0 1300 1322 nm zero dispersion slope s 0 0.092 ps/(nm²*km) refraction index at 1310 nm 1.467 at 1550 nm 1.468 88 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Fiber Data Sheet Singlemodefiber (SM) - Low Bend Sensitive E9 Common fiber type standard fiber describtion E9/125 Singlemode Fiber with higher Bend Performance ITU-T G.657 A1, A2/B2; IEC 60793-2-50 type B.1.3 The macrobending and microbending loss improvements of this low bend sensitive fiber offer a number of advantages for demanding access, enterprise and central office applications. The fiber enables more compact cabinet and enclosure designs and protects the network against excessive loss resulting from inadvertent fiber bends. It is less susceptible to physical disturbancees from cable flexing, pulling and crushing, as well as the intricate routing conditions within enclosures and cabinets. The optimized bend characteristics of this fiber also help improve cable performance in demanding high-stress and low-temperature environments by providing double the microbend protection of conventional singl-mode fibers. Mechanical Properties A1 A2/B2 core diameter d at 1310 nm 8.5-9.3 8.5-9.3 µm at 1550 nm 9.5-10.5 9.5-10.5 µm coreconcentricity error 0.5 0.5 µm cladding diameter 125 ±0.7 125 ±0.7 µm cladding non-circularity 1.0 1.0 % cladding/coating concentricity error 12.0 12.0 µm coating non-circularity 6.0 6.0 % fiber diameter uncoloured 235-245 235-245 µm coloured max. 265 max. 265 µm tensile strength according to EN 188000 PV201, 1s 8 8 N strain level 100 100 kpsi coating strip force 3.5 3.5 N bending radius 10 10 mm Optical Properties max. / typical max. / typical attenuation at 1310 nm 0.35 / 0.34 0.35 / 0.34 db/km at 1383 nm 0.31 / 0.28 0.31 / 0.28 db/km at 1490 nm 0.24 / 0.21 0.24 / 0.21 db/km at 1550 nm 0.21 / 0.19 0.21 / 0.19 db/km at 1625 nm 0.24 / 0.20 0.24 / 0.20 db/km refraction index at 1310 nm 1.467 1.467 at 1550 nm 1.468 1.468 attenuation inequality (...) at 1310 and 1550 nm 0.05 0.05 db/km attenuation alteration (range -60 up to +85 C) at 1310 und 1550 nm 0.05 0.05 db/km chromatic dispersion at 1288 1339 nm 3.5 3.5 ps/(nm*km) at 1550 nm 18 18 ps/(nm*km) polarization mode dipersion (PMD) 0.2 0.2 ps/ km fiber cut-off wavelength (referred to RTM) λ cf -range 1150 1330 1150 1330 nm cable cut-off wavelength λ cff -range 1260 1260 nm point defect at pulse-width 10ns at 1310 and 1550 nm 0.05 0.05 db zero dispersion wavelength λ 0 1302 1322 1300 1324 nm zero dispersion slope s 0 0.092 0.092 ps/(nm²*km) Macrobend Performances 100 turns on a 25mm radius mandrel at 1550 nm 0.01 - db at 1625 nm 0.05 - db 10 turns on a 15mm radius mandrel at 1550 nm 0.2 0.03 db at 1625 nm 0.5 0.1 db 1 turns on a 10mm radius mandrel at 1550 nm 0.2 0.1 db at 1625 nm 0.5 0.2 db 1 turns on a 7.5mm radius mandrel at 1550 nm - 0.5 db at 1625 nm - 1.0 db Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 89

Fiber Data Sheet NZDF-Singlemodefiber (NZDF) E8 Common fiber type standard fiber describtion Non-Zero-Dispersion-Shifted Singlemode Fiber ITU-T G.655, ITU-T G.656; EN188000, EN1888100, EN1888101 core consists of SiO 2 doped with GeO 2 ; optical cladding of quarzglass (SiO 2 ); step profile of the refraction index, matched cladding, phosphorus free; protective coating consisting of two layers of UV-cured acrylate resins Mechanical Characteristics G.656 G.655.d G.656 G.656 G.655.d (G.655.c, e) (G.655.c) (G.655.e) (G.655.e) True-Wave True-Wave Tera Light TM Tera Light TM Leaf Reach RS MetroFiber UltraFiber core diameter d at 1550 nm 8.6 ±0.4 8.4 ±0.6 9.2 ±0.5 9.2 ±0,5 9.6 ±0.4 µm at 1600 nm - 8.7 ±0.6 - - - µm cladding diameter 125 ±0.7 125 ±0.7 125 ±1 125 ±1 125 ±0.7 µm core/cladding excentricity 0.5 0.5 0.6 0.6 0.5 µm cladding non-circularity 0.7 0.7 1.0 1.0 0.7 % cladding/coating excentricity 12.0 12.0 12.0 12.0 12.0 µm coating non-circularity 6.0 6.0 5.0 6.0 6.0 % fiber diameter uncoloured 242 ±5 242 ±5 242 ±7 242 ±7 245 ±5 µm coloured 265 265 265 265 265 µm tensile strength according to 8 8 8 8 8 N EN 188000 PV201, 1s strain level 100 100 100 100 100 kpsi stripping force 3.5 3.5 3 3.5 3 N bending radius 30 30 30 30 30 mm Optical Characteristics attenuation at 1550 nm 0.22 0.22 0.25 0.22 0.22 db/km at 1625 nm 0.24 0.24 0.28 0.25 0.24 db/km attenuation (water peak) at 1383 ±3 nm 0.4 0.4 1.0 0.7 0.4 db/km attenuation (macrobending) 1 turn, 32mm at 1550 nm 0.5 0.5 0.5 0.5 0.5 db at 1625 nm 0.5 0.5 0.5 0.5 0.5 db 100 turns, 75mm 1) at 1550 nm 0.05 0.05 0.05 0.05 0.05 db at 1625 nm 0.05 0.05 0.05 0.05 0.05 db attenuation alteration 0.05 0.05 0.05 0.05 0.05 db/km (range -60 up to +85 C) no point discontinuity at 1550 nm 0.05 0.05 0.05 0.1 0.05 db chromatic dispersion at 1530 1565 nm 5.5-8.9 2.6-6.0 5.5-10.0 5.5-10.0 2.6-6.0 ps/(nm*km) at 1565 1620 nm 6.9-11.4 4.0-8.9 7.5-13.8 7.5-13.4 4.5-11.2 ps/(nm*km) polarisation mode- link design value 0.04 0.04 0.08 0.04 0.04 ps/ km dispersion (PMD) max. individual fiber 0.1 0.1 0.2-0.1 ps/ km point defect at 1550 nm 0.05 0.05 0.1 0.05 0.05 db refraction index at 1550 nm 1.470 1.470 1.469 1.469 1.468 1) at TeraLight TM Fibers: 60 mm 90 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Fiber Data Sheet NZDF-Singlemodefiber (NZDF) E8 Common fiber type standard fiber describition Non-Zero-Dispersion-Shifted Singlemode Fiber ITU-T G.655, ITU-T G.656; EN188000, EN1888100, EN1888101 PENGG KABEL offers non-zero dispersion shifted single mode optical fibers produced by the Vapour Phase Axial Deposition (VAD) method, which enables construction of high-capacy, ultra long haul WDM systems. This fibers allows the easier deployment of WDM in metropolitan areas, and increases the capacity of fiber in WDM systems throughout the wavelength region between 1460 nm and 1625 nm (S, C, L-bands, 1460 nm only for G.656 fiber). It s non-zero dispersion caracteristic reduces four-wave mixing and cross-phase modulation over a wider wavelength range than conventional NZDF. Our NZDF fibers has the ability to increase transmission speeds of systems up to 10 Gb/s and 40 Gb/s and also has superior polarization mode dispersion performance. Compostion core cladding coating Germanium doped silica Silica Dual layers of UV-cured acrylate Geometrical Characteristics G.656 G.655.a (G.655.c, e) (G.655.d) core diameter d at 1550 nm 9.0 ±0.5 9.6 ±0.4 µm cladding diameter 125.0 ±1.0 125.0 ±0.7 µm core/cladding concentricity error - 0.5 0.5 µm cladding non-circularity 0.7 0.7 % fiber curl radius 4 4 m primary coating diameter 242 ±5 245 ±5 µm coating/cladding concentricity error 12 12 µm Optical Characteristics attenuation at 1460 nm (only G.656) 0.26 - db/km at 1550 nm 0.22 0.22 db/km at 1625 nm 0.25 0.25 db/km point discontinuity at 1550 nm 0.10 0.05 db chromatic dispersion at 1460 to 1625 nm (only G.656) 2.0 bis 13.5 - ps/(nm*km) at 1530 to 1565 nm 5.5 bis 10.0 2.0 bis 6.0 ps/(nm*km) at 1565 to 1625 nm 7.5 bis 13.5 4.5 bis 11.2 ps/(nm*km) cut-off wavelength of cabled fiber 1450 1450 nm PMD individual fiber 0.10 0.10 ps/ km link design value (typical) - 0.04 ps/ km Mechanical Characteristics fiber proof test level 120 120 kpsi (1.2% strain) macrobending loss for 100 turns at a 75 or 60 mm mandrel diameter at 1550 (and 1625 nm at G.655.a) 0.05 0.05 db 1 turn at a 32 mm mandrel diameter at 1550 (and 1625 nm at G.655.a) 0.5 0.5 db coating strip force 1.3 bis 8.9 1.3 bis 8.9 N dynamic fatigue resistance parameter 20 20 Enviromental Characteristics induced attenuation at 1310 nm and 1550 nm from -60 C to +85 C temperature cycling 0.05 0.05 db/km 85 C / 98% RH temperature humidity cycling 0.05 0.05 db/km +85 C heating aging 0.05 0.05 db/km +23 C water immersion 0.05 0.05 db/km Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 91

Fiber Data Sheet Multimodefiber (MM) OM 2 - Quality G50 Common fiber type standard fiber describtion G50/125 according to VDE (Typ A1a), G50/125 according ÖVE or TA ITU-T G.651; EN188000, EN1888200, EN1888202; VDE0888/part 105, VDE0888/part 106, FZA TS0053/01 core consists of SiO 2 doped with GeO 2 ; optical cladding of quarzglass (SiO 2 ); graded profile of the refraction index, matched cladding, phosphorus free; protective coating consisting of two layers of UV-cured acrylate resins Mechanical Properties core diameter d 50 ±2.5 µm core non-circularity 5.0 % core/cladding concentricity error 1.5 µm cladding diameter 125 ±2 µm cladding non-circularity 1.0 % cladding/coating concentricity error 10.0 µm coating non-circularity 6.0 % fiber diameter uncoloured 245 ±10 µm coloured 265 µm tensile strength according to EN 188000 PV201, 1s 8 N strain level 100 kpsi stripping force 3.5 N bending radius 30 mm Optical Properties attenuation at 850nm 2.5 db/km at 1300 nm 0.6 db/km at 1383 nm 2.0 db/km band width at 850 nm 400-750 MHz*km (others on request) at 1300 nm 500-1200 MHz*km (others on request) attenuation (makrobending) 0.5 db attenuation alteration (range -60 up to +85 C) 0.2 db/km numeric aperture at 850 nm 0.2 ±0.015 refraction index at 850 nm 1.4825 at 1300 nm 1.4775 link lengths at 1 Gb/s at 850 nm 500-750 m at 1300 nm 550-2000 m 92 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Fiber Data Sheet Multimodefiber (MM) OM 3 - Quality (OM 3+, OM 4) G50 Common fiber type standard fiber describition G50/125 according to VDE (Typ A1a), G50/125 according ÖVE or TA ITU-T G.651; EN188000, EN1888200, EN1888202; VDE0888/part 105, VDE0888/part 106, FZA TS0053/01 core consists of SiO 2 doped with GeO 2 ; optical cladding of quarzglass (SiO 2 ); graded profile of the refraction index, matched cladding, phosphorus free; protective coating consisting of two layers of UV-cured acrylate resins Mechanical Properties core diameter d 50 ±2.5 µm core non-circularity 5.0 % core/cladding concentricity error 1.5 µm cladding diameter 125 ±1 µm cladding non-circularity 1.0 % cladding/coating concentricity error 10.0 µm coating non-circularity 6.0 % fiber diameter uncoloured 245 ±10 µm coloured 265 µm tensile strength according to EN 188000 PV201, 1s 8 N strain level 100 kpsi stripping force 3.5 N bending radius 30 mm Optical Properties attenuation at 850nm 2.5 db/km at 1300 nm 0.7 db/km at 1383 nm 2.0 db/km refraction index at 850 nm 1.4825 at 1300 nm 1.4775 attenuation (makrobending) 0.5 db attenuation alteration (range -60 up to +85 C) 0.2 db/km numeric aperture at 850 nm 0.2 ±0.015 Performance Characteristics OptiGrade Classes 300 400 500 550 Bandwith 850 nm 1500 2000 2500 3500 MHz*km (Overfilled Launch, LED based sources) 1300 nm 500 500 500 500 MHz*km Effective Modal Bandwith 850 nm 2000 2700 4000 4700 MHz*km Assured by: Differential Mode Delay (DMD) Fibers shall meet the respective DMD templates specified in or according to the standard TIA/EIA or IEC 60793-2-10, for transmitters meeting TIA/EIA-492 AAAC. Each template includes an inner and an outer mask requirement with: Inner mask: Outer mask: R inner = 5 µm to R outer = 18 µm R inner = 0 µm to R outer = 23 µm Upon request our fiber can be selected meeting inner mask radial specifications more stringent tha n the TIA/EIA-492 AAAC requirement: Inner mask: R inner = 0 µm to R outer = 18 µm Further to meeting the respective DMD template all OptiGrade fiber meets the additional requirement of IEC 60793-2-10 in the radial offset intervall masks, which sources out fibers, having rapid changes of the DMD. Transmission link lenghts 850 nm 300 400 500 550 m for 10 Gb/s* 1300 nm (LX4) 300 300 300 300 m *at 850 nm operating radius 4.5 µm 30 % wavelenth with transmitters radius 19.0 µm 86 % meeting encircled flux at Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 93

Fiber Data Sheet Multimodefiber (MM) G62,5 Common fiber type standard fiber describition G62,5/125 according to VDE (Typ A1b),, G62,5/125 according ÖVE or TA EN188000, EN1888200, EN1888202; VDE0888/part 105, VDE0888/part 107, FZA TS0053/01 core consists of SiO 2 doped with GeO 2 ; optical cladding of quarzglass (SiO 2 ); graded profile of the refraction index, matched cladding, phosphorus free; protective coating consisting of two layers of UV-cured acrylate resins Mechanical Properties core diameter d 62.5 ±2.5 µm core non-circularity 5.0 % cladding diameter 125 ±2 µm core/cladding concentricity error 1.5 µm cladding non-circularity 1.0 % cladding/coating excentricity 10.0 µm coating non-circularity 6.0 % fiber diameter uncoloured 245 ±10 µm coloured 265 µm tensile strength according to EN 188000 PV201, 1s 8 N strain level 100 kpsi stripping force 3.5 N bending radius 30 mm Optical Properties attenuation at 850nm 3.0 db/km at 1300 nm 1.0 db/km at 1383 nm 2.0 db/km band width at 850 nm 160-250 MHz*km (Standard 200) at 1300 nm 500-800 MHz*km (Standard 600) attenuation (makrobending) 0.05 db attenuation alteration (range -60 up to +85 C) 0.2 db/km numeric aperture at 850 nm 0.275 ±0.015 db refraction index at 850 nm 1.4965 at 1300 nm 1.4920 link lengths at 1 Gb/s at 850 nm 300-500 m at 1300 nm 550-1000 m 94 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Letter Symbols - Fiber Optics Letter symbols according to VDE (outdoor cables) Letter symbols according to VDE (indoor cables) Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 95

Colour Codes - Fiber Optics Colour Code - Fibers (Standard, others on request) Pengg Standard Fiber Colouring: Ring Signing: Colour Code - Tubes (Standard) 5-tubes construction 1 x n 2 x n 3 x n 4 x n 5 x n Singlemode Fibers NZDF-Fibers E8 Multimode Fibers G50 Multimode Fibers G62,5 no fiber assignment 6-tubes construction 1 x n 2 x n 3 x n 4 x n 5 x n 6 x n Singlemode Fibers E9 NZDF-Fibers E8 Multimode Fibers G50 Multimode Fibers G62,5 no fiber assignment 96 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

General Information Types page 98 Letter symbols page 99 Examples for telecommunication cables page 99 Basic formulas for telecommunication technique page 100 Units page 100 Basic formulas for homogeneous, symmetrical cables page 100 Shifting guideline page 102 Bending radius page 102 Installation temperature page 102 Tensile load for control and telecommunication cables page 102 Tensile load for telecommunication cables with guaranteeing tensile strength resistance page 103 Common explanations page 104 Pictograms Copper Cables page 104 Pictograms Fiber Optic Cables page 105 Characteristic features of insulation and sheath material page 105 RAL-colour code page 106 Behaviour in case of fire, fire away line, fire load page 107 Nominal data of wooden drums page 109 Drums according to DIN 46391 (dimensions, weights) page 109 Capacity (spooling length) page 110 Terms of delivery page 113 General Information Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 97

Types Signalling- and measuring cables Signal and measuring cables are used for transmission of DC- and low frequency AC-signals in telemetering-, signal-, clock- and paging systems as well as for control system (railway signals, signal boxes) and for supervision systems. The cables consist of PE-insulated cores, which are stranded together in concentric layers. The non-armoured types have a PVC-sheath over the cable core, the armoured types have a PVC-sheath (PE-sheath according to ÖVE), a steel tape armouring and a PVC-outer protective cover. Switchboard cables Switchboard cables are used as connection between racks, main distributors and switch stations in different kinds of railway offices (central offices, amplification bases and signal boxes). The cores are PVC-insulated. Cores are stranded together in layers; shielded pairs, triples, quads or quintuples are stranded together in layers or units. The shielded types have a screening of aluminium laminated PET-foil (static shield) over the cable core, the switchboard cables have a PVC-sheath. Local outdoor telecommunication cables They are used in local telecom networks, for the connection of telephone sets to telephone exchanges and as connection cables in industrial fields and in offices. The cables have quads of PE-, foam-pe- or foam-skin-pe insulated cores; the quads are stranded to unitss, the units are stranded to the cable core. The composite-layer sheath have a double-coated aluminium foil bonded with the PE-sheath. Petrol jelly fillings or swellable materials prevents water penetration along the cable. For special applications or customer-specifications the cables get additionally components, for example: PE-sheath, reinforced steel tape or steel wire armouring PE or PVC protective cover aluminium laminated PET-foil instead of aluminium tape Telecommunication switchboard wires They are used for switching and wiring of telecommunication instruments and similar ones, i.e. telephone exchanges, amplification bases and selection amplifiers. They consist of one or more twisted cores with PVC-insulation. Shielded switchboard strands They are used for switching of telecommunication instruments and similar ones, e.g. telephone exchanges, amplification bases and selection amplifiers. Shielded switchboard strands consists of one or more twisted, PVCinsulated cores, a copper braid screening and a PVC-sheath. Selfsupporting aerial cables Selfsupporting aerial carrier cables, so called SETRA cables, are used within the telecommunication network of the PTTs as well as in the domain of private telecom and data transmission networks. They have PE-insulated quads cabled to units and if necessary a shielding of aluminium foil; cable core and a supporting rope of galvanized steel wires with common PE-sheath (e.g. PVC-sheath). Also available with quads stranded in layers. Telecommunication installation wires Telecommunication installation wires are used for switching of telecom instruments in dry and eventually dump areas. They consists of one or more twisted PVC-insulated cores. Installation cables They are mainly needed for construction of telephone sets and extensions and suited for fixed laying on dry and wet ground material indoor and outdoor. The PVC-insulated pairs or quads are stranded together in layers or units. Depending on the type the cables are unshielded or shielded with an aluminium foil (static shield) and surrounded with a PVCsheath. Special cables for telecommunication Telecom cables for very specified applications and different special constructions (i.e. power protection cables, lightning protected telecommunication cables,railway signalling cables with inductive protection,...) belong to this field. Cables for industrial electronics These cables are used for transmission of signals and measuring values in units of the measuring, control and power electronic techniques as well as for data processing. They are composed of PVC-insulated cores or pairs stranded together into units. The shielded types have a screening of aluminium foil or copper braid. The cables for industrial electronics have a PVCsheath. Control cables Control cables are used for transmission of analogue and digital signals. Special constructions have proven to work under difficult transfer conditions and extreme severe environmental influences. Main applications: industrial process control, refineries, fuel dumps, chemical industry, power plants, as well as in sciences and research work. 98 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Letter symbols - copper cables Letter symbol Description A- outdoor cable (GE) A aluminium shield (AT) AB outdoor cable with high voltage protection (GE) AD- outdoor cable for power line protection (e.g. Differentialschutz) (GE) AJ- outdoor cable with inductive protection (GE) AL aluminium shield (DK) AL+PE aluminium-pe laminated sheath (DK) B armouring (AT/GE) BD cables with units (GE) (1B...) one layer steel tape;...mm thickness of steel tape (GE) C protective cover of tarred jute (GE) C shield (copper braid) (GE) C shield (copper tape) (AT) CU copper conductor (DK) D shield with stranded copper wires (GE) DM Dieselhorst-Martin quad (GE) E drain wire (AT) F filling of cable core (GE) F quad with phantom utilization (GE) F installation cable, flat design (GE) F flat wire armouring (AT) F- telecomunication outdoor cable (AT) FI- telecommunication indoor cable (AT) FOL foil (DK) (FA) longitudinally aluminiumtape (GE) (F...) flat wire; thickness in...mm (GE) G conter helix (AT) G- mine cable (GE) H skin (in foam-skin insulations) (AT) (H...) peak value of mutual capacitance [nf/km] (GE) J cable core jelly filled (AT) J- installations cable (GE) JE- installations cable for industrial electronics (GE)...IMF element with metallic foil and drain wire (AT/GE) -K additionally corrosion proofing over armouring (GE) (K) innersheath and shield of londgitudinally copper tape (GE) Kx coax pair (AT/GE) KF design with resistance to cold (GE) L smooth aluminium tape (GE) (L) laminated aluminium tape (GE) (L)2Y composite layer sheath (GE) L- sheathed flexible cable (GE) LD corrugated aluminium sheath (GE) Letter Description symbol LG cabling in layers (GE) LI stranded or bunched conductor (GE) M lead sheath (AT/GE) MZ lead sheath with addition of setting (GE) 2M lead sheath with addition of setting (AT) (M...) max. mean value of mutual capacitance [nf/km] (GE) OF filling of cable core with special material (GE) P paper insulation (AT/GE) P pair (GE) PAP paper (wrapping) (DK) PE polyethylene (outer) sheath (DK) perf perforated (GE) Q steel wire braid (AT/GE) (R...) round wire; diameter in... mm (GE) R round wire armouring (AT) S railway signalling cable (GE) S- switchboard cable (GE) S- railway signalling cable (AT) SMPE foam-skin-pe insulation (DK) SPE foam-pe insulation (DK) ST quad in cables for long distances and phantom utilisation (GE) ST I quad in cables for long distances (GE) ST III quad in local telecommuncation cables (GE) (S...) set value of mutual capacitance [nf/km] (GE) (ST) static shield of metallic tape or aluminium laminated pet-foil (GE) T suspension wire (AT/GE) TF carrier frequency quad (GE) TF swelling material (GE) V tinned copper wire (AT) VAS filling of cable core (DK) vzn tinned (GE) W corrugated steel sheath (GE) Y PVC insulation, sheath or protective cover PVC (AT/GE) YV PVC sheath or protective cover, reinforced (GE) Y3V PVC sheath or protective cover, reinforced (AT) (Z) steel- or PA-braid, rssistant to extension (GE) (ZG) glass yarn strength members (GE) 2Y PE isulation, sheath or protective cover (AT/GE) 2YV PE sheath or protective cover, reinforced (GE) 2Y3V PE sheath or protective cover, reinforced (AT) 02Y foam-pe insulation (AT/GE) 02YH foam-skin-pe insulation (AT) 02YS foam-skin-pe insulation (GE) Examples for telecommunication cables A-02YSF(L)2Y 200x2x0.8 ST III BD Longitudinally waterproof local telecommunication cable with 100 foam-skin PE insulated quads, bare copper conductor, diameter 0.8 mm, stranded to units, jelly filled, paper tape covering and composite layer sheath; (similar to FTZ). J-Y(ST)Y 20x2x0.6 LG Installation cablel with 20 PVC-insulated pairs, bare copper conductor, diameter 0,6 mm, stranded in layers, plastic tape wrapping, static shield PETP aluminium foil with drain wire and PVC-sheath; (according to VDE 0815). A-2YYBY 16x1x0.9 S LG Railway signal cable with 16 PE insulated cores, stranded in layers, bare copper conductor, diameter 0.9 mm, plastic tape wrapping, PVCsheath, stell tape armouring and PVC protective cover (according to VDE 0816/part 2). General Information Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 99

Basic Formulas of Telecommunication Technique Units Term Symbol Letter symbol Unit angular frequency ω s -1 1/second attenuation (equivalent) a, α db (Np) dezibel (neper) attenuation coefficient α db/km (Np/km) dezibel (neper)/km capacitance load per unit length C F/km farad/km capacitance unbalance k, / k 1 / k 2,3 /k 9-12 / e 1,2 pf pikofarad conductivity κ Sm/mm² siemensmeter/mm² conductance G ms/km millisiemens/km conductance per unit length G S/km siemens/km conductor cross section q mm² millimeter² conductor resistance R Ω/km ohm/km current, strength of current I A ampere dissipation factor tan δ - - frequency f Hz hertz group delay τ g s/km second/km inductivity L mh/km millihenry/km inductivity load per unit length L H/km henry/km insulation resistance R is MΩkm megaohmkilometer image phase change coefficient β rad/km rad/km impedance (amount) Z Ω ohm impedance (complex) Z L Ω ohm impedance (imaginary part) Z i Ω ohm impedance (real part) Z r Ω ohm line length l km kilometer level p db (Np) dezibel (neper) magnetic unbalance m nh nanohenry mutual capacitance C nf/km nanofarad/km mutual inductance M mh/km millihenry/km near end cross talk attenuation (equivalent) a n, α n db (Np) dezibel (neper) phase delay τ p s/km second/km power P W watt reduction factor r k - - reflection coefficient r - - relative permittivity ε r - - resistance load per unit length R Ω/km ohm/km specific resistance s Ωmm²/m ohm mm²/m temperature t C degree celsius velocity of propagation v ü bit/s bit/second voltage U V volt wave length λ m meter Basic formulas for homogeneous, symmetrical cables Conductor resistance R t resistance at t C in Ohm R 20 resistance at 20 C in Ohm t temperature in C k 0.00393 for Cu or 0.00403 for Al Complex characteristic impedance Angular frequency Dissipation factor (Ω) 100 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Basic Formulas of Telecommunication Technique Basic formulas for homogeneous, symmetrical cables Impedance (amount) at low frequencies (voice frequency) Impedance (amount) at high frequencies (ω L>R) (Ω) (Ω) L C inductivity (H/km) mutual capacitance (F/km) Attenuation at low frequencies (voice frequency) Attenuation at high frequencies (w L>R) (Np/km) (Np/km) (db/km) R G loop resistance (Ω/km) conductance (S/km) General Information Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 101

Shifting Guideline Bending radius When laying and bending the cables as well as at the mounting points (e.g. brackets) the bending radius R may not come up to those below stated. When forming out the cables during the assembly of appropriate treatment the minimum bending radius may be reduced at the most to half of the indicated values. Cable typ installation cables, switchboard cables Bending radius R minimum value 7.5 x D A outdoor cables with composite layer sheath outdoor cables 7.5 x D A 10 x D A D A... cable outer diameter Installation temperature For the transfer not the ambient temperature but the temperature of the cable is determining. With low ambient temperatures cables can be warmed up before shifting by suitable measures in such a way that the cable inside is not cooling under the permissible shifting temperature during the entire shifting procedure. Stress and jerks as well as stress by impact are to be avoided at low temperatures. The pulling speed of the cables should be as even as possible. temperature range during installation: cables with Polyethylene sheath (PE) -20ºC up to +50ºC cables with Polyvinylchlorid sheath (PVC) -5ºC up to + 50ºC Tensile load for control- and telecommunication cables (according to VDE 0891/part 6) The tensile stress indicated in the following tables applies uniformly to all for with guaranteeing tensile strength armouring cable, with which is included the cable core frictional connected with the cable sheath - either over a tie rod with pulling eye or a firmly mounting pulling trunk. Number of Maximum allowed value of tensile load [N] cores Conductor diam. 0.9 1.4 1.8 4 100 300 500 5 150 400 650 8 250 600 1000 12 350 900 1450 16 500 1200 1900 21 650 1500 2400 27 800 1900 3100 33 1000 2300 3700 40 1200 2700 4400 48 1450 3200 5300 56 1650 3700 5800 65 1950 4300 6700 75 2200 4800 7600 80 2350 5100 8000 96 2800 6000 9200 108 3100 6800 10000 114 3250 7100 10600 133 3700 7900 12000 147 4000 8600 13000 154 4200 8900 13500 176 4700 9900 15200 200 5300 11000 17000 102 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Shifting Guideline Tensile strength of telecommunication outdoor cables with guaranteeing tensile strength resistance Number of double cores Maximum allowed value of tensile load [N] Conductor diam. 0.4 0.6 0.8 0.9 1.2 1.4 5 350 6 250 400 10 300 500 600 700 1200 1600 20 400 700 1000 1300 2300 2800 30 500 950 1500 1900 3200 4000 40 650 1200 2000 2500 4100 5200 50 750 1500 2500 3000 5000 6400 60 850 1700 2900 3500 6000 7500 70 1000 2000 3400 4100 6700 8500 80 1100 2300 3800 4600 7500 9500 100 1400 2800 4600 5700 9000 11400 120 1600 3400 5400 6600 10500 150 2000 4100 6600 8000 12500 200 2600 5200 8500 10000 15700 250 3300 6400 10000 12000 18800 300 3900 7400 11500 13500 20000 350 4300 8600 13000 15000 400 4900 9600 14500 16300 500 5900 11500 17000 18700 600 6800 13200 19000 700 7600 14500 20500 800 8400 15500 21500 1000 9800 17500 1200 11000 19000 1500 12500 2000 14400 The values in the tables above refer to unarmoured cables with no guaranteeing tensile strength armouring. If higher traction loads are necessary, cables with a a garanteeing tensile strength armouring (steel round or rectangular wire) are to be planned. For the calculation of the tensile load for such cables applies an approximate value of 12 dan for each mm 2 steel cross section. General Information Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 103

Common Explanations Pictograms Copper Cables All datasheets are signed with common pictograms, which describe the cable make up and will lighten the localisation of the most applicable cable type. Mutual capacitance C35 C38 C42 C50 C52 C55 C60 Dimension of copper conductor conductor diameter [mm] 0,4 0,5 0,6 0,8 0,9 1,0 1,2 1,4 1,8 cross section [mm 2 ] Cable elements core pair triple quad quintuple pair in metal foil PIMF Number of double cores (DC) DC, talking circuit DC 4 DC 2-4 DC 4-8 DC n Filling unfilled petrol jelly Füllnidz dry filling / swellable materials Overall screening, armouring unshielded foil copper braid or tape foil and copper braid copper wires composite layer (L) armouring (steel tape, round steel wires) 104 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Common Explanations Pictograms Fiber Optic Cables metal-free halogenfree, flame retardant rodent protection longitudinally water-tight indoor cable outdoor cable aerial cable (ADSS) Characteristic features of insulation and sheath materials Material Resistance to Spec. volume Continous possible break-down resistance operating temperature [kv/mm] [Ωcm] dauernd [ C] PVC (standard compound) 25 10 13 20 up to +70 PVC (compound for telephon cores) 25 10 15 10 up to +70 LDPE 70 10 17 50 up to +70 HDPE 85 10 17 50 up to +90 Foam-PE 60 10 17 50 up to +70 Material Operating temperatur Decomposition- Inflammability (short time) or distortion- [ C] temperature [ C] PVC (standard compound) +100 +120 self-extinguishing PVC (compound for telephon cores) +100 +120 self-extinguishing LDPE +100 +110 inflammable HDPE +120 +130 inflammable Foam-PE +90 +110 inflammable Material Water- Weather- Chemical Radioabsorption proof resistance resistance % (general) x10 6 rad PVC (standard compound) 0.4 good limited 17 PVC (compound for telephon cores) 0.4 good limited 17 LDPE 0.1 good limited good 19 HDPE 0.1 limited limited good 19 Schaum-PE 0.1 good limited good 19 Material Relative Density Tensile Breaking Letterpermittivity strength elongation symbol ε [g/cm 3 ] [MPa] % PVC (standard compound) 5 8 1.45 15 250 Y PVC (compound for telephon cores) 3 4 1.4 20 200 Y LDPE 2.3 0.92 20 400 2Y HDPE 2.3 0.945 25 500 2Y...HD Foam-PE 1.6 0.65 10 500 02Y General Information Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 105

Common Explanations RAL-colour code colour- colour huenumber expresion 1001 beige beige 1012 yellow lemon yellow 1013 white oyster white 1014 ivory ivory 1015 beige light ivory 1016 yellow sulfur yellow 1019 beige grey beige 1021 yellow rape yellow 2000 orange yellow orange 2002 orange vermilion 2003 orange pastel orange 2004 orange pure orange 3000 red flame red 3002 red carmine red 3004 red purple red 3015 pink light pink 4001 violet red lilac 4003 violet hether violet 4005 violet blue lilac 5002 blue ultramarine blue 5010 blue gentian blue 5012 blue light blue 5014 blue pigeon blue colour- colour huenumber expresion 5015 light blue sky blue 5019 blue capri blue 6000 green patina green 6001 green emerald green 6003 green olive green 6005 green moss green 6010 green grass green 6018 green yellow green 6027 turquoise light green 7000 grey squirrel grey 7001 grey silver grey 7021 grey black grey 7032 grey (ptt grey) pebble grey 7035 grey light grey 7037 grey dusty grey 8003 brown clay grey 8011 brown nut brown 8014 brown sepia brown 8024 brown beige brown 9001 white cream 9005 black jet black 9007 silver grey grey aluminium 9010 white pure white 106 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Behaviour in Case of Fire, Fire Away Line, Fire Load Requirement In the European standards EN 50167, EN 50168 and EN 50169 data cables with halogen-free outer sheath are required. The consideration and adherence to these standards are recommended particularly with public setting e.g. hospitals, schools and airports. In addition with other buildings with high person or real value concentration a use of halogen-free cables is practical. Cable with PVC-sheath In the case of fire standard PVC materials can transmit fires and form hydrochloric acid (HCI) by splitting off hydrogen chloride gas in connection with moisture (e.g. fire fighting water). It continues to co me to a strong smoke development with burning PVC (polyvinyl chloride) and the corrosive damage at buildings and equipment can often devastating extents assume, which exceed far the actual fire damage. Testing method according to IEC 60332-1 Samples From the end of the tested cable a sample piece of 600±25 mm is taken. Preparation (fig.1) Propane from cylinder with burner, flame height 175 mm. Sample is hung up vertically into the center of a metal box, (metal box: h=1200±25 mm, b=300±25 mm, t=450±25 mm, front open). Flame cone of the gas burner has to be fixed in an angle of 45 approx. 100 mm above the lower sample. With cable diameter up to 50 mm one burner is used, with cable diameter over 50 mm two burners are used. Execution t = 60 + m 25 t = duration of the flaming action in s m = weight of the sample in g Cables with halogenfree sheath Hereby materials are used, which do not contain halogens (e.g. chlorine) and which do not set free corrosive gases in the case of fire. Also the proportion of toxic gases is reduced to a minimum, and smoke development and fire away line are hardly still available or possible. Designation notes at the cable are e.g. the abbreviations FRNC or LSOH. In detail these designations are meaning: FR flame retardant (fire-away-line-restraining) NC non corrosiv (no corrosive constituents) LS low smoke (low smoke development) 0H zero halogen (halogen-free) Another big advantage by using such materials is, that the free view on gears and escape routes is kept. Please note that you have to take care that such kinds of materials are also used by other products, e.g. power cables or cable run channels. Fire load [kwh/m], [MJ/m] In each building there are many different inflammable installations or products. Also cable and cores (although hidden in intermediate ceilings or channels), which can in particular represent a substantial component in administration buildings belong to them. These cables have most divergent powers (heat values) and the total fire load of a building could clearly increase. Therefore you should be pay attention to the fact, when planning that the fire load quantities are kept as small as possible. Analysis The test is considered as positively passed if the sample did not burn or the flames automatically go out and the fire damage does not reach the upper end of the sample. Fire-pure e.g. soot lining and colour modification are not does claimed. Testing method according to IEC 60332-2 Samples From the end of the tested cable a sample piece of 600±25 mm is taken. Preparation Propane from cylinder with burner, flame height 125 mm. Sample is hung up vertically into the center of a metal box, (metal box: h=1200±25 mm, b=300±25 mm, t=450±25 mm, front open). Flame cone of the gas burner has to be fixed in an angle of 45 approx. 100 mm above the lower sample. Execution max. 20s Analysis The test is considered as positively passed if the sample did not burn or the flames automatically go out and the fire damage does not reach the upper end of the sample. Fire-pure e.g. soot lining and colour modification are not does claimed. General Information Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 107

Behaviour in Case of Fire, Fire Away Line, Fire Load Testing methodes according to IEC 60332-3 Samples From the end of the tested cable sample pieces of 360 mm are taken. The number of samples depends on the cable diameter. Testing method 1 Testing methode 3 Preparation (fig. 2) The samples are arranged at the test rack as follows: Telecommunication cables and cords as well as control cables and cords with an outside diameter 30 mm without distance. The number has to be selected in such a way that the grouping width results of min.180 mm; the distance of the outside samples to the lateral side piece of the ladder should be approx. 90 up to 120 mm; mounting of the samples with steel wires; the test rack is inserted vertically into the suspension of the furnace. Dimensions of the furnance as well as air volume and temperature are exactly regulated. Burner, 77.7±4.8 l/min propane and 13.5±0.5 l/h air measured at 20 C and 1 bar. Before starting the test the test set-up has to be conditioned at room temperature for mind. 16 h. Flame of the gas burner has to be fixed in an angle of 90 approx. 600 mm above the lower sample end, in a distance of 75 mm. Execution Duration of the flaming action at least min. 20 minutes Analysis The test is considered as positively passed if the sample did not burn or the flames automatically go out and the fire damage does not reach the upper end of the sample. Fire-pure e.g. soot lining and color modification are not does claimed. Fig.1 Fig.2 The test according to test type 3 shows very realistically the possible fire in a vertical duct. 108 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Nominal Data of Wooden Drums (DIN 46391) Drums according to DIN 46391 (dimensions, weights) identification drum flange-diameter barrel-diameter width traverse width carrying drumnumber dimesion D d B b capacity weight [mm] [mm] [mm] [mm] aprrox. [kg] aprrox. [kg] 051 05 500 150 470 400 8 E6 06 600 300 450 20 061 06 630 315 415 315 250 13 071 07 710 355 500 400 400 25 E8 08 800 400 560 40 081 08 800 400 500 400 600 31 091 09 900 450 670 560 800 47 E10 10 1000 550 700 80 101 10 1000 500 690 560 900 71 E12 12 1200 700 790 150 121 12 1250 630 860 666 1700 144 E14 14 1400 850 870 200 141 14 1400 710 870 660 2000 175 E16 16 1600 1000 970 350 161 16/8 1600 800 1060 844 3000 280 162 16/10 1600 1000 1100 835 3000 271 E18 18 1800 1150 1110 500 181 18/10 1800 1000 1060 835 4000 380 182 18/12 1800 1250 1100 825 4000 352 E20 20 2000 1300 1190 600 201 20/12 2000 1250 1310 1035 5000 550 202 20/14 2000 1400 1345 1030 5000 544 E22 22 2200 1450 1330 700 221 22/14 2240 1400 1410 1140 6000 710 222 22/16 2240 1600 1475 1130 6000 738 E24 24 2400 1600 1380 900 250 25/14 2500 1400 1450 1140 7500 875 251 25/16 2500 1600 1450 1130 7500 900 252 25/18 2500 1800 1475 1120 7500 909 E26 26 2600 1700 1450 1100 E28 28 2800 1800 1650 1400 281 28/18 2800 1800 1590 1280 10000 1175 E30 30 3000 1900 1270 10000 1600 up to drum dimension 10 with cable bushing General Information Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 109