Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

Similar documents
Applied Biosystems Real-Time PCR Rapid Assay Development Guidelines

AmpFlSTR Identifiler PCR Amplification Kit

HID Real-Time PCR Analysis Software v1.1

Validation of a Multiplexed System for Quantification of Human DNA and Human Male DNA and Detection of PCR Inhibitors in Biological Samples

Validation Using SDS Software Version on the Applied Biosystems 7500 Real-Time PCR System and the ABI PRISM 7000 Sequence Detection System

Forensic News. FAS Corner April The Maximizing Data Quality Series Part 2: DNA Quantitation

Simple, Complete Workflows for Gene Expression Analysis without RNA Purification

Introducing a new generation of affordable choices from the leader in real-time PCR. Applied Biosystems 7500 Fast Real-Time PCR System

Data Quality Worth Sharing

TaqMan Protein Assays

ABI Prism 6100 Nucleic Acid PrepStation

FastLane Kits from Sample Direct to Result

HID Real-Time PCR Analysis Software v1.3

Table of contents. I. Description...2. II. Principle...2. III. Kit Components...3. IV. Storage...3. V. Features...4. VI. Precautions for Operation...


THUNDERBIRD SYBR qpcr Mix

AutoMate Express Forensic DNA Extraction System

Applied Biosystems 7900HT Fast Real-Time PCR System. Performing Fast Gene Quantitation with 384-Well Plates DRAFT

PRODUCT BROCHURE PCR Systems. Veriti Thermal Cycler The Power of MORE

Expression Array System

Sartorius Microbiology Products Keeping your Quality under Control

User Bulletin. Veriti 96-Well Thermal Cycler AmpFlSTR Kit Validation. Overview

Applied Biosystems 7500 Fast Real-Time PCR System

Real-Time PCR Validations

resdnaseq Quantitative DNA Kits

Applied Biosystems 7500 Fast, 7500 and 7300 Real-Time PCR Systems

Reliable extraction of DNA from Whatman FTA cards

Protocol. Path-ID Multiplex One-Step RT-PCR Kit Protocol TaqMan probe-based multiplex one-step real-time RT-PCR detection of RNA targets

TaqMan Protein Assays Probe Development

mirna QPCR Master Mix

User Bulletin. ABI PRISM 7000 Sequence Detection System DRAFT. SUBJECT: Software Upgrade from Version 1.0 to 1.1. Version 1.

TaqPath ProAmp Master Mixes

Same TaqMan Assay quality, new format

Absolute Quantification Getting Started Guide

M. tuberculosis_mpb64/is61 10 genesig Standard Kit

Premix Ex Taq (Probe qpcr)

For in vitro Veterinary Diagnostics only. Kylt Brachyspira spp. Real-Time PCR Detection.

RapidFinder TM Goat ID Kit

Love Bird (Agapornis) Sexing Sex chromosome specific spindlin gene. Advanced Kit. 150 tests. For general laboratory and research use only

CaMV promoter & NOS terminator detection

RNA-direct Realtime PCR Master Mix

Evaluation of the PowerQuant System on the QuantStudio 5 Real-Time PCR System

For in vitro Veterinary Diagnostics only. Real-Time PCR Detection Kit for detection of Histomonas meleagridis.

SYBR Green Realtime PCR Master Mix

For in vitro Veterinary Diagnostics only. Kylt Avian Hepatitis E. Real-Time RT-PCR Detection.

AmpliTaq 360 DNA Polymerase

SYBR Green Realtime PCR Master Mix -Plus-

Escherichia coli_o104: H4

Simplify your pathogen testing. Amplify your confidence.

M. tuberculosis_mpb64/is611. genesig Advanced Kit. 150 tests. Primerdesign Ltd. For general laboratory and research use only

FOR RESEARCH USE ONLY. NOT FOR HUMAN OR DIAGNOSTIC USE.

Georgia Bureau of Investigation - Division of Forensic Sciences DNA Procedures Manual DNA QUANTIFICATION USING QUANTIFILER HUMAN / Y HUMAN MALE KIT

Investigator Quantiplex HYres Kit

Human Y-Chromosome detection assay

Maize CaMV promoter & NOS terminator (GMO)

mirna QPCR Master Mix

PowerPlex. Y System Validation

For in vitro Veterinary Diagnostics only. Kylt Avian Nephritis Virus. Real-Time RT-PCR Detection.

Acinetobacter baumannii

PowerPlex ESX & ESI Fast Systems

Cat. # R100A. For Research Use. EpiScope MSP Kit. Product Manual. v1103da

For in vitro Veterinary Diagnostics only. Kylt Chicken Astrovirus. Real-Time RT-PCR Detection.

Mycobacterium genus (all species)

FMV 35S promoter (GMO) Advanced Kit. FMV 35S promoter. 150 tests. For general laboratory and research use only

Pistacia vera. Introduction to Pistacia vera. 100 tests. Techne qpcr test. For general laboratory and research use only

Latest Tools for Human Identification

Equus caballus Horse Speciation Kit

#K0262 For 1000 reactions of 25 µl Lot Exp.. Store at -20 C in the dark. V

For in vitro Veterinary Diagnostics only. Kylt MHRS Triplex. Real-Time PCR Detection.

For in vitro Veterinary Diagnostics only. Kylt Influenza A - H9. Real-Time RT-PCR Detection.

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for resuspending the SingleShot RNA control template

Techne qpcr test. A graveolens. NADPH-dependent mannose 6- phosphate reductase (m6pr) 100 tests

Techne qpcr test. Pisum sativum. Ribosomal protein S12 (rps12) gene. 100 tests

Brilliant II SYBR Green QPCR Master Mix

For feed and food applications only. Kylt Staphylococcus aureus. Real-Time PCR Detection Kit for detection of Staphylococcus aureus.


Helicobacter pylori. genesig Standard Kit. RNA polymerase beta-subunit (rpob) gene. 150 tests. Primerdesign Ltd

Human Herpes Virus 1 (Herpes simplex type 1)

Mir-X mirna First-Strand Synthesis and SYBR qrt-pcr

Relative Quantification (Mono-Color) Unknown samples (purified total RNA, mrna or cdna or genomic DNA)

Bacteriophage MS2. genesig Standard Kit. Phage MS2 genome. 150 tests. Primerdesign Ltd. For general laboratory and research use only

Reference gene detection assay. Instructions for detection and quantification of a reference gene using SYBR Green detection chemistry

For in vitro Veterinary Diagnostics only. Kylt Chlamydiaceae Screening. Real-Time PCR Detection.

Human bocavirus. genesig Standard Kit. Viral protein (VP) gene. 150 tests. Primerdesign Ltd. For general laboratory and research use only

Sus scrofa Pig genesig Speciation Kit

Relative Quantification Getting Started Guide

A Recommended Procedure for Real-Time Quantitative TaqMan PCR for Roundup Ready Canola RT73 Monsanto Biotechnology Regulatory Sciences

Technical Review. Real time PCR

MAXimum results. Minimum effort.

Soya Round up Ready (RR)

Mycobacterium Tuberculosis

Anacardium occidentale

Saccharomyces cerevisiae

For in vitro Veterinary Diagnostics only. Detection Reagents specific for. Chlamydia psittaci Real-Time PCR.

For in vitro Veterinary Diagnostics only. Kylt E. coli F18, F41, Stx2e. Real-Time PCR Detection.

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for resuspending the SingleShot RNA control template


Perform an HRM Methylation Study

Candida dubliniensis. genesig Standard Kit. Cytosine deaminase (FCA1) gene. 150 tests. Primerdesign Ltd. For general laboratory and research use only

For in vitro Veterinary Diagnostics only. Real-Time RT-PCR Detection Kit for Avian Hepatitis E Virus

Transcription:

Product Bulletin Human Identification Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit The Quantifiler kits produce reliable and reproducible results, helping to select the appropriate short tandem repeat (STR) analysis method, reducing costs and saving time The Quantifiler Y Human Male DNA Quantification Kit is the first commercially available kit for male DNA quantification, a valuable tool for sexual assault sample analysis Pre-formulated Internal PCR Control (IPC) in each reaction allows quick identification of samples that may be inhibited or that do not contain human DNA Both Quantifiler kits utilize the same, simple protocol that requires fewer steps, minimizing hands-on time, and reducing manual error Both Quantifiler kits deliver specific, robust quantification of samples with DNA concentrations of 0.023µg/L to > 50µg/L Introduction DNA quantification forensic samples ensure optimal STR analysis. Quantifying the amount of amplifiable human DNA and human male DNA prior to subsequent STR analysis is fast, easy, and reliable, thanks to two reagent kits from Applied Biosystems. The Quantifiler Human DNA Quantification Kit and the Quantifiler Y Human Male DNA Quantification Kit provide reliable, reproducible, and highly sensitive real-time PCR quantification results for human identity samples. Optimized and validated for use with the Applied Biosystems 7500 Real-Time PCR System and the ABI PRISM 7000 Sequence Detection System, the Quantifiler kits provide an ideal quantification solution to meet the stringent requirements of the human identification community. The Quantifiler Y Human Male DNA Quantification Kit provides additional value when analyzing samples that may contain mixtures of female and male DNA, by specifically amplifying a target only found on the Y chromosome. Applied Biosystems offer the most complete, integrated system for the quantitation and STR analysis, including validated reagent kits, instruments, analysis software, technical training, and customer support services. Leading the way, the Human Identification group at Applied Biosystems offers the best scientific solutions continuing to enable laboratories to process more samples more efficiently. No other company delivers the depth of products, expertise, and applications support that are available for human identification applications. Reliable. Reproducible. Real-Time. The Quantifiler kits are optimized for use with the same simple protocol, utilizing the 5' nuclease assay (real-time PCR) and TaqMan probe-based technology for maximum reliability and ease of use (see Figure 1). During the real-time PCR assay, the accumulating fluorescent-labeled PCR product is monitored as amplification occurs, allowing the analyst to view the cycle-

to-cycle increase in the fluorescent signal (see Figure 2). Since the Quantifiler kits are based on well characterized PCR technology that determines the amount of DNA present in a sample, the results provide an accurate assessment of how downstream STR analysis will perform. Because Applied Biosystems quantification kits and AmpFlSTR kits utilize the same PCR technology, the Quantifiler kits provide the most accurate indication of subsequent STR analysis available. With one mouse click the real-time PCR amplification results are obtained using the Quantifiler kits, the 7000 and 7500 System Software automatically calculates the amount of total amplifiable DNA present in each sample. The calculation is determined by the cycle number at which the amount of amplified product crosses the noise threshold in each reaction. For each sample, the cycle number is then compared against a standard curve generated from a series of DNA standards, translating the cycle number into a DNA concentration. The Quantifiler Human DNA Standard is included in each kit and is simultaneously amplified with forensic samples on the same reaction plate. The values can then be used to select the appropriate amount of amplifiable DNA that can be added to subsequent STR amplification. The Quantifiler kits enable balanced STR results to be obtained the first time reducing the test cost and time to reportable result. Streamline Workflow. Ensure Superior Results The Quantifiler kits include all reagents necessary for the amplification, detection, and quantification of 400 reactions using the Applied Biosystems 7500 Real-Time PCR System or the ABI PRISM 7000 Sequence Detection System. Each kit contains three reagent components: Quantifiler PCR Mix Quantifiler Human Primer Mix or Quantifiler Y Male Primer Mix Quantifiler Human DNA Standard Both Quantifiler kits utilize the same reagents and allow the user to select the appropriate Quantifiler Primer Mix, which contains a pre-formulated mixture of primers and probes that amplify either the Human Telomerase Reverse Transcriptase gene (Quantifiler Human Kit) or the SRY gene (Quantifiler Y Kit). By amplifying both systems in a single tube, the Quantifiler kits provide an indicator of potential sample inhibition, and allow for quick identification of samples that do not contain human DNA. Each kit includes the Quantifiler Primer Mix specific for either the Quantifiler Human or Quantifiler Y Human Male Assay, 1 bottle of the Quantifiler PCR Reaction Mix, and 1 tube of the Quantifiler Human DNA Standard, sufficient for 400 reactions. The Quantifier Human Primer Mix and Quantifiler Y Male Primer Mix is formulated specifically to amplify the Human Reverse Transcriptase gene or SRY gene and is pre-formulated with the IPC system. Fast and Easy Protocol The Quantifiler kits minimize the labor required by reducing procedural steps and accelerating time-to-results. The simple protocol includes preparation of a DNA standard curve, setting up the PCR reactions, and clicking Start to begin amplification and detection. No additional steps are required. Unlike other quantification methods, the Quantifiler kits protocol does not require lengthy incubation steps, tubes to open and close, sample-transfer steps, or mid-process mixing and washing. The entire quantification procedure can be completed in approximately thirty minutes of hands-on time, providing robust, reproducible results Figure 1. Real-time PCR reaction. FORWARD PRIMER PROBE REVERSE PRIMER 1. Polymerization: A fluorescent reporter (R) dye and a quencher (Q) are attached to the 5' and 3' ends of a TaqMan probe, respectively. 2. Strand displacement: When the probe is intact, the reporter dye emission is quenched.

a b c for up to 80 samples and one set of standard curves (an 8 point standard curve run in duplicate). Because they use the same amplification and detection parameters, both kits can be run on a single plate, yielding results for up to 64 samples and two sets of standard curves (see Figure 3). Minimal hands-on time allows analysts to focus on other aspects of their laboratory work, and reduces the possibility of errors that may occur with multiple handling steps. Users of the Quantifiler kits have greater confidence in the reliability of their DNA quantification results. The easy, three-step protocol for reaction setup together with automated amplification, detection, and analysis procedures makes DNA quantification a simple, streamlined procedure. Validated Protocols for a Variety of Sample Types The Quantifiler kit components and amplification protocols are validated and optimized as a component of Applied Biosystems integrated systems for human identification applications. Stringent validation by the manufacturer ensures specific, robust amplification of human identity samples with DNA concentrations of 0.023µg/L to >50µg/L. Figure 2. Data obtained using Quantifiler Kits. 2a. Example of a positive DNA sample. 2b. Example of a sample with no detectable DNA. 2c. Example of a sample that is inhibited. 3. Cleavage: During each extension cycle, the DNA polymerase cleaves the reporter dye from the probe. 4. Polymerization completed: Once separated from the quencher, the reporter dye emits its characteristic fluorescence.

A B C D E F G H 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G H 1 2 3 4 5 6 7 8 9 10 11 12 Rows 1 2: Quantifiler Kit Standards (8-point standard curve run in duplicate) Rows 3 12: Quantifiler Kit Samples Rows 1 2: Quantifiler Human Kit Standards (8-point standard curve run in duplicate) Rows 3 6: Quantifiler Human Kit Samples Rows 7 8: Quantifiler Y Kit Standards (8-point standard curve run in duplicate) Rows 9 12: Quantifiler Y Kit Samples Figure 3. Examples of possible plate setups using the Quantifiler and Quantifiler Y Human DNA Quantification Kits. Experiments to evaluate the Quantifiler kits were performed at Applied Biosystems, according to the DNA Advisory Board (DAB) guidelines, Quality Assurance Standard for Forensic DNA Testing Laboratories. Complete protocols and a summary of the experiments performed and results obtained for developmental validation are available in the Quantifiler Kits User s Manual. For information on Applied Biosystems developmental validation of the Quantifiler kits please reference the article Developmental Validation of the Quantifiler Real-Time PCR Kits for the Quantification of Human Nuclear DNA Samples, Journal of Forensic Sciences, July 2005. Both Quantifiler kits require minimal sample handling and quantify DNA from a wide variety of human identity sample types, including, but not limited to, buccal swabs, blood, semen, and tissue samples. The quantification protocol is compatible with several commonly used DNA extraction methods including Phenol-Chloroform, Chelex, and silica based chemistries. Once samples are extracted, loaded into the quantification tubes, and sealed, no further sample handling is required. This ensures sample integrity and reduces the risk of contamination. Complete System Approach to Quantification Applied Biosystems offers fully integrated reagents, instruments and analysis software for processing data generated in human identification laboratories. DNA samples quantified with the Quantifiler kits may be amplified and analyzed with the ABI PRISM Sequence Detection System that accommodates an individual laboratory s throughput needs. Each Sequence Detection System includes all of the software necessary to amplify, detect, and analyze samples processed using both Quantifiler kits. Stringent Quality Control Each Quantifiler kit lot is subjected to stringent quality control testing to help ensure reliability and reproducibility from lot to lot. Applied Biosystems develops and manufactures its products in accordance with ISO 9001 quality system requirements. Additionally, a Certificate of Analysis is available upon request, which confirms that the specific components of the kits meet quality-assurance testing specifications. The Quantifiler and Quantifiler Y Human Quantification Kits convey certain specific rights to perform paternity and forensics testing services in conjunction with an Authorized Thermal Cycler such as the Applied Biosystems 7500 Real-Time PCR System or the ABI PRISM 7000 Sequence Detection System.

Highly Trained Forensic Application Specialists Applied Biosystems highly trained and experienced Forensic Application Specialists are available either by telephone or online to assist your laboratory with the implementation and use of the Quantifiler kits. Additional training on the use of the Quantifiler kits and Sequence. Detection Systems can be provided on site by a Forensic Application Specialist with the purchase of a new Applied Biosystems 7500 Real-Time PCR System or ABI PRISM 7000 Sequence Detection System and a Quantifiler kit. Applied Biosystems 7500 Real-Time PCR System and Quantifiler Kits. Features and Benefits at a Glance Both Quantifiler kits meet the Human Identification community s requirements for highly sensitive quantification results Quantification results more accurately reflect the performance of DNA amplification that will be observed in downstream PCR-based applications An IPC is pre-formulated in each reaction, allowing you to quickly identify samples that may be inhibited or that do not contain human DNA Easy-to-follow protocol minimizes hands-on time and reduces the possibility of contamination Reliable and reproducible results, produced with a single mouse click Both Quantifiler kits have a greater than 2,000-fold dynamic range of detection delivering quantification of samples with DNA concentrations of 0.023ng/µL to > 50ng/µL. Quantifiler Y and Yfiler kits can be used together to obtain the most comprehensive information present in sexual assault samples

Ordering Information Description Rxns x Total Rxn Volume P/N Quantifiler Human DNA Quantification Kit 400 x 25 µl 4343895 Quantifiler Y Human Male DNA 400 x 25 µl 4343906 Quantification Kit Quantifiler Human DNA Kit User s Manual 4344790 ABI PRISM 7000 Sequence Detection System (Laptop) 4349132 ABI PRISM 7000 Sequence Detection System (Tower) 4349117 Applied Biosystems 7500 Real-Time PCR System (Laptop) 4366604 Applied Biosystems 7500 Real-Time PCR System (Tower) 4366605 For Research, Forensic or Paternity Use Only. Not for use in diagnostic procedures. Notice to Purchaser: Limited License The purchase price of this product includes a limited, non-transferable license under U.S. patents and patent claims outside the United States, for using only this amount of product in the practice of the 5 nuclease process solely in forensic and paternity testing, including reporting results of purchaser s activities for a fee or other commercial consideration and also for the purchaser s own internal research. No right under any other patent claims (such as apparatus or system claims for real-time PCR) and no right to use this product for any other purpose, is hereby granted expressly, by implication, or by estoppel. Further information on purchasing licenses may be obtained from the Director of Licensing, Applied Biosystems, 850 Lincoln Centre Drive, Foster City, California 94404, USA. AB (Design), Quantifiler, and Yfiler are trademarks, and ABI PRISM and Applied Biosystems are registered trademarks of Applied Biosystems or its subsidiaries in the US and/or certain other countries. TaqMan is a registered trademark of Roche Molecular Systems, Inc. 2005, 2010 Applied Biosystems. All rights reserved. Printed in the USA, 09/10. P+s Publication 112PB12-04. Headquarters 850 Lincoln Centre Drive Foster City, CA 94404 USA Phone 650.638.5800 Toll Free 800.345.5224 International Sales For our office locations please call the division headquarters or refer to our Web site at /about/offices.cfm