Corrosion Studies on GeoBrom HG520

Similar documents
Corrosion Studies on GeoBrom HG520

Corrosion Studies on GeoBrom HG520

SUB-Programs - Calibration range Fe Base for "PMI-MASTER Pro" Spark - mode Fe 000

SUB-Programs - Calibration range Fe Base for "FOUNDRY-MASTER UV"

Bottom Ash Data Week 52

Bottom Ash Data Week 45

Bottom Ash Data Week 47

CERTIFICATE OF ANALYSIS 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION

CERTIFICATE OF ANALYSIS

HAIR ELEMENTS. PATIENT: Number 496 SEX: Female AGE: 70. POTENTIALLY TOXIC ELEMENTS TOXIC RESULT REFERENCE PERCENTILE ELEMENTS µg/g RANGE 68 th 95 th

Certificate of Analysis

SILLIKER, Inc. Southern California Laboratory 6360 Gateway Drive, Cypress, CA Tel. 209/ Fax. 714/

CERTIFICATE OF ANALYSIS 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION

Standard Solutions (Traceable to NIST)

Appendix C: Water Quality Data

Standard Solutions (Traceable to NIST)

High Purity Acids Trace Elemental Analysis. Detect as low as 1 to 100 ppt

RITES Lab, Western Region, 210, Amit Industrial Estate, 61, Dr. S.S. Rao Road, Parel, Mumbai, Maharashtra

French Creek Well # 2 Water Analysis Behind 1221 Ormonde Road

CERTIFICATE OF ANALYSIS REVISED REPORT

Improved Antimony Recoveries in Soil Matrices by 3050B/6010B. DataChem Laboratories, Inc. Robert P. Di Rienzo Jeffery S. Ward John T.

Background Statement for SEMI Draft Document 4795 (Yellow Ballot) NEW STANDARD: SPECIFICATIONS FOR NITRIC ACID, USED IN PHOTOVOLTAIC APPLICATIONS

This method is applicable to the following parameters: Nitric Hydrochloric acid digestion, Instrumental analysis.

Raw Potable Well Water Analysis: Grid Water Analysis: 2009 & 2016

Aluminum 18 i. 0 Antimony

Background Statement for SEMI Draft Document 5134 Revision to SEMI C , Specifications for Hydrofluoric Acid

SEMI C SPECIFICATIONS AND GUIDELINES FOR AMMONIUM HYDROXIDE

Predicting Reaction Products

9 Toxins / 11 Essential Minerals

Background The document will be revised for its five year review and updated per the committee agreed upon changes.

Center for By-Products Utilization

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation

AAS - Atomic Absorption Mono Element ppm Standard Solutions (Spectro ECON)

CERTIFICATE OF ANALYSIS REVISED REPORT

um"ts: m1 1grams per rt1er (mg./l)

CARBOWAX SENTRY Polyethylene Glycol (PEG) and Methoxypolyethylene Glycol (MPEG) Products

Practice General Chemistry Speaking Test (I. Gould) (Questions from Chapter 1 of the textbook) hydrogen 1 H

Background Statement for SEMI Draft Document 4546A REVISION OF SEMI C , with title change to SPECIFICATIONS FOR HYDROGEN PEROXIDE

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation

SEMI C SPECIFICATIONS AND GUIDELINES FOR HYDROGEN PEROXIDE

Material Evaporation Application Comment MP P / Optical films, Oxide films, Electrical contacts. Doping, Electrical contacts.

BLACK STURGEON LAKES WATER QUALITY MONITORING

Increased Sample Throughput for ICP-OES Applied to U.S. EPA Method 200.7

CERTIFICATE OF ANALYSIS

BLACK STURGEON LAKES WATER QUALITY MONITORING

CERTIFICATE OF ANALYSIS

ICP/ICP-MS Standards. High Purity Standards for ICP/ICP-MS

Appendix U. Mapping of Water Quality Concentration Contours across the Province

Strong Acid Leachable Metals (SALM) in Soil - Prescriptive

High-Purity Acids & Reagents

UltraPur TMP. Trimethylphosphite FEATURES & BENEFITS. Canisters and delivery systems APPLICATIONS

Analysis of Metals in Water, Stream Sediments and Floodplain Soils Collected March 21-23, 2005 from the Bayou Creek System. David J.

Geoscience BC. Regional Geochemical Surveys. Standards of Execution for RGS/NGR Surveys

BURNCO AGGREGATE PROJECT

CERTIFICATE OF ANALYSIS

Safety Data Sheets (SDSs) Soon To be Avalable for Purchase from AFS

Recommended List of Common Impurities for Metallic Fixed-point Materials of the ITS-90

This resource contains three different versions of the periodic table, including a blank one for colouring!

Traceable Reference Standards for Plasma Emission Spectroscopy

A.M. MONDAY, 18 January minutes

CERTIFICATE OF ANALYSIS

Chapter 1.6. Polished Single-Crystal Silicon, Prime Wafers (all numbers nominal) Wafer Specification Table. Diameter 100 mm 4-inch 150 mm 6-inch

ARC XL Series. Broadband g-line & i-line Anti-Reflective Coatings

Water Monitoring - Teralba Quarry EPA Point No.4 - Adit Overflow

ADDITIONAL SCIENCE/CHEMISTRY. A.M. TUESDAY, 14 January hour

ADDITIONAL SCIENCE/CHEMISTRY. A.M. TUESDAY, 14 January hour

Fly Ash Testing Results PEI Energy Systems Waste Combustion Ash

General Certificate of Secondary Education ADDITIONAL SCIENCE. FOUNDATION TIER (Grades G-C) P.M. FRIDAY, 18 January 2008 (45 minutes)

Laboratory Turnaround Times and Prices

Part 1. Preparation and Color of Solutions. Experiment 1 (2 session lab) Electrons and Solution Color. Pre-lab Report, page 29

Organometallic Standards for AA, ICP, DCP & XRF Analysis

New GCSE 4472/02 ADDITIONAL SCIENCE

Appendix V6-2A Analytical Results of the Umwelt Westbay Groundwater Sampling Program

Participate in proficiency testing studies semi-annually, with the following exception

P.M. THURSDAY, 15 January minutes

METALLIC MATERIALS SPECIFICATION HANDBOOK

New GCSE 4462/02 SCIENCE A HIGHER TIER CHEMISTRY 1

Microbac Laboratories, Inc. AZ0723

MATERIALS H 01. Temescal & Telemark Liners... H 03 Satis Liners... H 05 Crucible Liners Selection Table... H 06

Amplifying ICPMS Productivity Using Discrete Sampling Technology

CERTIFICATE OF ANALYSIS

Regarding: Dry Stack Tailings Facility Construction and Operation Plan Revision 2, QML 0009

ADDITIONAL SCIENCE/CHEMISTRY

Test Report No.: NBTY Date: AUG 07, 2014 Page 1 of 5

LABORATORY TURNAROUND TIMES AND CHARGES

ADDITIONAL SCIENCE/CHEMISTRY

MATERIALS H 01. Liners...H 03 Crucible Liners Selection Table...H 06. MATERIALS / Inorganics & thin films guide

Periodic Table Of The Elements

New GCSE 4472/02 ADDITIONAL SCIENCE HIGHER TIER CHEMISTRY 2

ADDITIONAL SCIENCE/CHEMISTRY

ADDITIONAL SCIENCE/CHEMISTRY

ENVIRONMENTAL LABORATORY LICENSE AZ0723

2. GUIDELINES FOR THE EVALUATION OF DRINKING-WATER QUALITY FOR HUMAN CONSUMPTION WITH REGARD TO CHEMICAL, PHYSICAL AND BACTERIOLOGICAL QUALITY

GCSE 4462/02 CHEMISTRY 1 HIGHER TIER SCIENCE A/CHEMISTRY. A.M. FRIDAY, 17 June hour JUN S PMT.

GCSE 4472/02 CHEMISTRY 2 HIGHER TIER ADDITIONAL SCIENCE/CHEMISTRY. P.M. MONDAY, 20 May hour For Examiner s use only Question Maximum Mark 1.

Name: 1: /33 Grade: /100 2: /33 3: /33 +1 point. Midterm Exam 2. CHEM 181: Introduction to Chemical Principles October 13, 2015

Crucible MATERIALS H 01. Temescal & Telemark Liners...H 03 Satis Liners...H 05 Crucible Liners Selection Table...H 06

Info Bulletin Laboratory Chemicals, Molecular Biology Culture Media for Microbiology

The objective of this document is to specify the chemicals characteristics and properties of the material Steel AISI Carbon Steel.

P.M. THURSDAY, 15 January minutes

Transcription:

Corrosion Studies on GeoBrom HG520 Vapor Space Study a Chemtura business

Great Lakes Solutions: brominated derivative products for mercury control Contents Background Information 1 Objectives 1 Executive Summary 2 Description of Test Procedure 2 Results and Discussion 3 Conclusion 3 Tables and Figures 4-12

Great Lakes Solutions: Innovative. Reliable. Sustainable. Background Information A 90-day vapor space corrosion rate study was conducted using GeoBrom HG520 calcium bromide solution and six selected metals at 20 and 50 C. ASTM Method Standard Practice for Preparing, Cleaning, and Evaluating Corrosion Test Specimens G1-03 (reapproved 2011) was used to prepare, clean, and evaluate tests specimens. The following six metals were evaluated: C-1018 mild carbon steel coupon 304-W 304SS welded coupon 316-LW 316SS, low carbon, welded coupon 2205 Duplex 2205 coupon 304-LW 304SS, low carbon, welded coupon 316 316SS coupon Objectives of the Study 1. Establish above surface vapor corrosion rates at 20 C and 50 C for each metal. 2. Visually document coupon condition before and after 90-day exposure. Corrosion Studies on GeoBrom HG520 1

Executive Summary All specimens were less than 0.06 mpy corrosion rate based on this 90-day study. Mild carbon steel (C-1018) gave the highest rates at 0.025 mpy at 20 C and 0.053 mpy at 50 C. All remaining specimens were under 0.015 mpy. Minor surface corrosion was observed on both C1018 coupons. There was no visible corrosion on remaining test specimens, and all test solutions remained water clear after 90 days. The maximum allowable corrosion rate for each specimen with GeoBrom HG520 depends on the application. Description of Test Procedure Metal test coupons with dimensions of ~ 2.0 x 0.75 x 0.125 were supplied by an outside vendor. The vendor prepared the coupons by abrading surfaces and stamping metal type and marking specimens with a unique identification number. Prior to using, coupons were cleaned using reagent grade aqueous HCl and a bristle brush followed by a thorough deionized water rinse, degreased using acetone, dried using hot air, then allowed to cool in desiccators. The clean, dry specimens were weighed and measured. Using forceps, a four place OHAUS Galaxy Model G160D analytical balance was used to attain initial weights for all coupons. Dimensions were established using a Starrett Micrometer part # 436RL-1, EDP 51568 and a Starrett Dial Caliper Part # 120Z, EDP 55951. Three measurements were taken on all dimensions and averaged for the length, width, and thickness. Pictures were taken to record coupon condition prior to vapor exposure tests. Test coupons were split into two groups, containing specimens of each metal type, and placed into individual 4-oz bottles with Teflon liners. Coupons were suspended 3/8 inches above the liquid surface using Teflon string. One group was placed in a Yamato Model DVS600 drying oven to hold samples at 50 C and the second group placed in a controlled environment room held at 20 C. There was no agitation or aeration of the test specimens while in the glass bottles. 2 Great Lakes Solutions, a Chemtura business

Duration of the test was 90 days and 1 hour or 2,161 hours. Prior to cleaning, pictures were taken to record coupon condition after the 90 day immersion test. After cleaning, pictures were taken again. None of the specimens were heavily corroded, so post immersion cleaning was simple and consisted of the following: 1. Immersion in deionized water to remove test solution 2. Immersion and brushed in aq. HCl (for mild carbon steel), and nitric acid (for the stainless steels) 3. Thoroughly rinsed with deionized water, then immediately dried. The C1018 coupon required light scrubbing using a brush in deionized water. Table A1.1 in ASTM G1-03 was used as a guide to select cleaning procedure for removal of corrosion products. After drying test specimens with hot air and then allowing them to cool in desiccators, all specimens were re-weighed and the final weights recorded Spreadsheets were developed to capture data and to make calculations per ASTM method. Calculated metal densities and published metal densities were used in corrosion rate calculations for comparison. The average corrosion rate calculation per ASTM G1-03 is: Corrosion Rate = (K x W) / (A x T x D) K = a constant (K) constant listed in ASTM G1-03, Section 8 for desired units T = time of exposure in hours A = area in cm 2 W = mass loss in grams D = density in gm/cm 3 Results and Discussion Tables 1 and 2 provide data on test specimens at 20 C and at 50 C, respectively. Corrosion rates on all specimens were under 0.10 mpy rate. Mild carbon steel C-1018 gave the highest corrosion rate at 0.025 mpy at 20 C and 0.053 mpy at 50 C. Minor surface corrosion but no pitting was observed on C-1018 coupons. There was no surface corrosion or pitting observed on any remaining specimens suspended above the liquid by ~ 3/8 inches. C-1018 corrosion is likely due to humidity in headspace of bottle. Corrosion rates for each specimen were charted to reflect trends over the two temperatures 20 C and 50 C (see Figure 1). GeoBrom HG520 test solutions were saved for Inductively Coupled Plasma (ICP) analysis before and after the immersion tests. After the 90-day period, all GeoBrom HG520 solutions remained water clear. To verify that there was no significant increase in any metals after 90 days, ICP analysis was conducted only on GeoBrom HG520 used for the C-1018 coupon, since the C-1018 coupon had the highest corrosion rate after 90 days at 50 C. See Table 4 for metals concentrations in test fluid at start, at end, and the difference. Data verified that there is little to no increase in metals. All bottles were sealed, but a small amount of water vapor may have vented over 90 days resulting in a slight increase in metals. To visually document condition of test specimens, pictures were taken before and after immersion tests (see Figures 2-6). Conclusion C-1018 showed signs of a slight surface corrosion in this test and a low corrosion rate. There are a number of different corrosion standards depending on the application. Therefore, whether C-1018 is suitable for use with CaBr 2 depends on the application. These data are relevant only to the 52% CaBr 2 solution. Dilute solutions or other uses of 52% solution may exhibit different corrosive behaviors. Corrosion Studies on GeoBrom HG520 3

Figure 1 Corrosion Rate Trend Chart with Y Axis at 0 to 0.06 mpy Scale Corrosion Coupons at 20 and 50 C Subsurface in GeoBrom HG520 Calcium Bromide Solution Corrosion Rate in (mpy) using Calculated Density 0.070 0.060 0.050 0.040 0.030 0.020 0.010 0.000 At 20 o C At 50 o C Temperature of Test Solution of 14.2 ppg Aqueous Calcium Bromide C-1018 304-W 316-LW 2205 304-LW 316 4 Great Lakes Solutions, a Chemtura business

Table 1 Vapor Space at 20 C Corrosion Coupon Testing with GeoBrom HG520 Calcium Bromide Solution Vapor Space at 20 C May 31, 2013 - August 29, 2013 Total Exposure Time: 90 Days Using ASTM Designation: G1-03 (reapproved 2011) standard practice for preparing, cleaning, and evaluating corrosion test specimens Coupon Type C-1018 304-W 316-LW 2205 304-LW 316 Identification Mark A1689 A0027 A8156 five dot A0016 A1167 Weight (grams) 22.0307 23.0696 19.9073 21.7531 23.2976 20.1366 Length (inches) 2.016 2.001 2.001 2.015 2.010 1.997 Width (inches) 0.772 0.765 0.746 0.762 0.761 0.750 Thickness (inches) 0.122 0.131 0.114 0.122 0.132 0.114 Hole dia. (inches) 0.375 0.376 0.375 0.377 0.376 0.377 Calculated Density (gm/cc) 7.603 7.594 7.685 7.642 7.620 7.762 Published Density (gm/cc) ASTM 7.86 7.94 7.94 7.805 7.94 7.98 Calculated Surface Area (sq. cm) 23.982 23.965 22.763 23.675 24.012 22.812 Start date (MDY) 8/14/2013 8/14/2013 8/14/2013 8/14/2013 8/14/2013 8/14/2013 Start time (hours) 9:30 9:30 9:30 9:30 9:30 9:30 End date (MDY) 11/12/2013 11/12/2013 11/12/2013 11/12/2013 11/12/2013 11/12/2013 End time (hours) 10:30 10:30 10:30 10:30 10:30 10:30 Temperature ( C) 20 20 20 20 20 20 Exposure Time (hours) 2161 2161 2161 2161 2161 2161 Ending Weight (grams) 22.0278 23.0686 19.9069 21.7526 23.2966 20.1363 Loss in Weight (grams) 0.0029 0.001 0.0004 0.0005 0.001 0.0003 Rate of Corrosion (mpy) using calculated density Rate of Corrosion (mpy) using published density 0.0254 0.0088 0.0037 0.0044 0.0087 0.0027 0.0246 0.0084 0.0035 0.0043 0.0084 0.0026 Corrosion Studies on GeoBrom HG520 5

Table 2 Vapor Space at 50 C Corrosion Coupon Testing with GeoBrom HG520 Calcium Bromide Solution Vapor Space at 50 C May 31, 2013 - August 29, 2013 Total Exposure Time: 90 Days Using ASTM Designation: G1-03 (reapproved 2011) standard practice for preparing, cleaning, and evaluating corrosion test specimens Coupon Type C-1018 304-W 316-LW 2205 304-LW 316 Identification Mark A1690 A0028 A8157 six dot A0017 A1168 Weight (grams) 21.8898 21.7960 20.0162 21.3550 22.7820 20.0809 Length (inches) 2.018 2.001 2.001 1.999 2.003 2.005 Width (inches) 0.773 0.759 0.749 0.751 0.758 0.750 Thickness (inches) 0.122 0.125 0.114 0.122 0.130 0.114 Hole dia. (inches) 0.378 0.374 0.375 0.382 0.375 0.378 Calculated Density (gm/cc) 7.578 7.573 7.695 7.705 7.616 7.759 Published Density (gm/cc) ASTM 7.86 7.94 7.94 7.805 7.94 7.98 Calculated Surface Area (sq. cm) 23.995 23.561 22.843 23.162 23.766 22.859 Start date (MDY) 8/14/2013 8/14/2013 8/14/2013 8/14/2013 8/14/2013 8/14/2013 Start time (hours) 9:30 9:30 9:30 9:30 9:30 9:30 End date (MDY) 11/12/2013 11/12/2013 11/12/2013 11/12/2013 11/12/2013 11/12/2013 End time (hours) 10:30 10:30 10:30 10:30 10:30 10:30 Temperature ( C) 50 50 50 50 50 50 Exposure Time (hours) 2161 2161 2161 2161 2161 2161 Ending Weight (grams) 21.8838 21.7944 20.0156 21.3542 22.7807 20.0803 Loss in Weight (grams) 0.006 0.0016 0.0006 0.0008 0.0013 0.0006 Rate of Corrosion (mpy) using calculated density Rate of Corrosion (mpy) using published density 0.0527 0.0143 0.0054 0.0072 0.0115 0.0054 0.0508 0.0137 0.0053 0.0071 0.0110 0.0053 6 Great Lakes Solutions, a Chemtura business

Table 3 Composition of Specimens Chemical Composition of Specimens Tested during 90-Day Total Immersion Study AISI = American Iron and Steel Institute Data in % by weight Metal Type AISI 1018 AISI 304 AISI 304-L AISI 316 AISI 316-L Duplex 2205 Carbon 0.15-0.20 0.08 max 0.03 max 0.08 max 0.03 max <0.03 Manganese 0.60-0.90 2 max 2 max 2 max 3 max < 2 Phosphorous 0.040 max 0.045 max 0.045 max 0.045 max 0.045 max < 0.03 Sulfur 0.050 max 0.03 max 0.03 max 0.03 max 0.03 max < 0.02 Silicon 0.15 to 0.30 0.75 max 0.75 max 1 max 2 max < 1 Chromium N/A 18-20 18-20 16-18 17-18 21-23 Nickel N/A 8 to 12 8 to 12 10 to 14 11 to 14 4.5-6.5 Molybdenum N/A N/A N/A 2 to 3 2 to 3 2.5-3.5 Nitrogen N/A 0.10 max 0.10 max N/A N/A 0.8-2.0 Iron balance balance balance balance balance balance Corrosion Studies on GeoBrom HG520 7

Table 4 Metals in Test Fluid ICP Analysis Before and After 90-Day Vapor Space Corrosion Rate Study: C1018 Coupon Bottle was sealed but some slight water vapor loss may have occurred Metals in sample Metals in sample 50 C Test Metal ID Before after at 50 C. Difference Ag (Silver) 1.66 5.54 3.88 Al (Aluminum) 10.12 7.58-2.54 As (Arsenic) 4.36 3.83-0.53 B (Boron) 2.11 2.65 0.54 Ba (Barium) 3.40 7.46 4.06 Be (Beryllium) 0.13 1.13 1.00 Bi (Bismuth) 10.41 8.56-1.85 Cd (Cadmium) 1.33 3.23 1.9 Ce (Cerium) 4.01 NA Co (Cobalt) 2.09 3.57 1.48 Cr(II) (Chromium) 2.36 6.10 3.74 Cu (Copper) 0.54 1.09 0.55 Fe(II) (Iron) 1.66 3.42 1.76 Little to no increase in iron K (Potassium) NA NA La (Lanthanum) 9.46 NA Li (Lithium) 2.73 4.25 1.52 Mg (Magnesium) 570.37 854.44 284.07 Mn (Manganese) 1.58 4.26 2.68 Mo (Molybdenum) 4.04 8.23 4.19 Na (Sodium) 97.65 82.35-15.3 Ni (Nickel) 2.14 1.93-0.21 Pb (Lead) 12.74 4.88-7.86 Rb (Rubidium) 0.34 1.98 1.64 Sb (Antimony) 1.28 2.86 1.58 Se (Selenium) 6.26 6.33 0.07 Sn (Tin) 7.05 4.01-3.04 Sr (Strontium) 73.41 116.25 42.84 Ti (Titanium) 0.89 4.04 3.15 Tl (Thallium) 17.17 22.64 5.47 U (Uranium) 1.75 6.57 4.82 V (Vanadium) 13.85 21.28 7.43 Zn(I) (Zinc) 16.07 6.64-9.43 Note: Metals highlighted in the table are major components in the coupons evaluated. Significant increases in the concentration of these metals would be an indication of corrosion of the coupons. 8 Great Lakes Solutions, a Chemtura business

Figure 2 Test Coupons Before 90-Day Above Surface Exposure at 20 C and 50 C C1018 304W 316LW Duplex 2205 304LW 316 Corrosion Studies on GeoBrom HG520 9

Figure 3 Test Coupons After 90-Day Above Surface Exposure at 20 C Still in Test Bottles (before cleaning) C1018 304W 316LW Duplex 2205 304LW 316 Test Coupons After 90-Day Above Surface Exposure at 50 C Still in Test Bottles (before cleaning) C1018 304W 316LW Duplex 2205 304LW 316 10 Great Lakes Solutions, a Chemtura business

Figure 4 Test Coupons After 90-Day Above Surface Exposure at 20 C Removed From Test Bottles (before cleaning) C1018 304W 316LW Duplex 2205 304LW 316 Test Coupons After 90-Day Above Surface Exposure at 50 C Removed From Test Bottles (before cleaning) C1018 304W 316LW Duplex 2205 304LW 316 Figure 5 C1018 Coupon After 90-Day Above Surface Exposure at 20 C and 50 C (before cleaning) @ 20 C @ 50 C C1018 C1018 Corrosion Studies on GeoBrom HG520 11

Figure 6 Test Coupons After 90-Day Above Surface Exposure at 20 C Removed From Test Bottles (after cleaning) C1018 304W 316LW Duplex 2205 304LW 316 Test Coupons After 90-Day Above Surface Exposure at 50 C Removed From Test Bottles (after cleaning) C1018 304W 316LW Duplex 2205 304LW 316 12 Great Lakes Solutions, a Chemtura business

Corrosion Studies on GeoBrom HG520 13

Great Lakes Solutions, a Chemtura business 1801 Sagamore Parkway West Lafayette, Indiana 47906 Phone: 1-800-428-7947 or 1-765-497-6100 The information contained herein is correct to the best of our knowledge. Your attention is directed to the pertinent Material Safety Data Sheets for the products mentioned herein. All sales are subject to Chemtura s standard terms and conditions of sale, copies of which are available upon request and which are part of Chemtura s invoices and/or acknowledgements. Except as expressly provided in Chemtura s standard terms and conditions of sale, no warranty express or implied, including warranty of merchantability or fitness for a particular purpose, is made with respect to the product described herein. Nothing contained herein shall constitute permission or recommendation to practice any invention covered by a patent without license from the owner of the patent. Unless otherwise indicated, the trademarks in this brochure are trademarks of Chemtura Corporation and/or its subsidiaries. For more information or to email us, visit us on the web at: www.greatlakes.com/geobrom