Florida Product Approval # R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 D

Similar documents
Residential, 26 Ga. Roof Panel over 15/32 Plywood. Florida Product Approval # R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 D

Residential, 29 Ga. Roof Panel over 15/32 Plywood. Florida Product Approval # R3 Florida Building Code 2017 Per Rule61G20-3 Method: 1 D

Mech-Seam Standing Seam Roof Panel over open framing. Florida Product Approval # R1 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 D

26 Ga. Ultra-Rib Roof Panel over 15/32 Plywood. Florida Product Approval # R3 Florida Building Code 2014 Per Rule 61G20-3 Method: 1 D

1.5 Snap Lock 24 Ga. Roof Panel over Plywood. Florida Product Approval # R3 Florida Building Code 2014 Per Rule 61G20-3 Method: 1 D

FLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R2. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

FLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

FLORIDA PRODUCT APPROVAL 5VCRIMP FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

VERSALOC SRTM 1 24GA. VERSALOC SR 161/2 WIDE ROOF PANEL OVER 15/32 PLYWOOD

FLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

FLORIDA PRODUCT APPROVAL 5VCRIMP FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

FLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

FLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

Compliance Statement: The product as described in this report has demonstrated compliance with

RidgeLine Standing Seam Roof Panel over open framing. Florida Product Approval # Florida Building Code 2014 Per Rule 61G20-3 Method: 1 D

Force Engineering & Testing Inc Ramblewood Drive. Humble,TX Product Evaluation Report SENTRIGARD METAL ROOFING SYSTEMS

CBUCK Engineering. Florida Product Approval # FL R1

CBUCK Engineering. Evaluation Report M-Seam Metal Roof Assembly

CBUCK Engineering. Florida Product Approval # FL R2

CBUCK Engineering. Evaluation Report Cee Lock Panel Metal Roof Assembly

CBUCK Engineering. Florida Product Approval # FL R1

CBUCK Engineering. Product: Zee-Lock Roof Panel Material: Steel Panel Thickness: 24 gauge Panel Width: 16 Support: Wood Deck

CBUCK Engineering. Evaluation Report Englert Series 1100 Metal Roof Assembly. Manufacturer:

Prepared for: Thompson Architectural Metals Company, Inc E. Hillsborough Avenue Tampa, FL 33605

CBUCK Engineering. Florida Product Approval # FL R3

CBUCK Engineering. Florida Product Approval # FL R2

CBUCK Engineering. Evaluation Report Zee-Lock Panel or Curved Zee-Lock Panel Metal Roof Assembly

CBUCK Engineering. Evaluation Report Zee-Lock Panel With Floating Zee-Clip Metal Roof Assembly

CBUCK Engineering. Florida Product Approval # FL R2

CBUCK Engineering. Florida Product Approval # FL R2

CBUCK Engineering. Evaluation Report S-Tile Metal Roof Assembly

CBUCK Engineering. Evaluation Report Zee-Lock Panel With Continous Zee-Rib Clip Metal Roof Assembly

Metal Roof Certification & Listing Program

CBUCK Engineering. for. Florida Product Approval # FL R1

CBUCK Engineering. Evaluation Report 5V Crimp Metal Roof Assembly

CBUCK Engineering. Evaluation Report Englert Series 500 Metal Roof Assembly Manufacturer: Englert, Inc Amboy Avenue Perth Amboy, NJ

Force Engineering & Testing Inc Ramblewood Drive. Humble,TX Product Evaluation Report

CBUCK Engineering. for. Florida Product Approval # FL R2

CBUCK Engineering. for. Florida Product Approval # FL R1

Metal Roof Certification & Listing Program

Metal Roof Certification & Listing Program. 1. Program Licensee: This Certification Report was used to qualify Florida Product Approval FL

Metal Roof Certification & Listing Program. 4. Evaluated Roof System Description: 1. Program Licensee: 2. Certified Roof Covering: 5.

CBUCK Engineering. Evaluation Report FW-1025 Panel with Optional Seamlock Metal Roof Assembly

CBUCK Engineering. Evaluation Report Flush Seam Metal Wall Assembly

Certification Report.

Force Engineering & Testing Inc Ramblewood Drive. Humble,TX Product Evaluation Report

Metal Roof Certification & Listing Program

CBUCK Engineering. for. Florida Product Approval # FL R2

Metal Roof Certification & Listing Program

CBUCK Engineering. Wood Deck

CBUCK Engineering. Evaluation Report MMI Off Ridge Vent

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Evaluation Report MMI Off Ridge Vent & Attached Permanent Baffle

CBUCK Engineering. Evaluation Report MI Off Ridge Vent Ridge Vent Assembly

Exterior Research & Design, L.L.C. Building Science and Envelope Consultants

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Evaluation Report. Die Formed Skirt Ridge Ventilator. "12 Inch Throat" Manufacturer. Metallic Products Corporation Hollister Road

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

8"'0.., ~f' ~'" NOTICE OF ACCEPTANCE (NOA) Petersen Aluminum Corporation 1005 Tonne Road Elk Village, Illinois 60007

ML200 Panel Technical Data Guide

CREEK Technical Services, LLC

CBUCK Engineering. Evaluation Report Fixed Blades Wall Louver MPF G

SL175 Panel Technical Data Guide

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY

Evaluation Report SkylightTube Tubular Daylight Device

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

_II. NOTICE OF ACCEPTANCE (NOA) Petersen Aluminum Corporation 1005 Tonne Road Elk Grove Village, Illinois 60007

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Table of Contents. 3. Standing Seam Panels

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT (203)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Originally Issued: 09/19/2014 Revised: 10/17/2017 Valid Through: 11/15/2017

EVALUATION REPORT Boral Roofing /MonierLifetile 7575 Irvine Center Drive Suite 100 Irvine, CA

TRIAD CORRUGATED METAL, INC.

CREEK Technical Services, LLC

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # CHRISTIAN STREET, UNIT 13 OXFORD, CT (203)

Addendum No. 1. ITB for Emergency Management/Utilities Administration Building Renovation Addendum Release Date April 06, 2017

Section Property Standard Year Wind FM Physical Properties ASTM D

TRIAD CORRUGATED METAL, INC.

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Section Property Standard Year Static Uplift Resistance TAS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICE EVALUATION CRITERIA FOR

SSL-175. Specifications

Product Evaluation Report of. JELD-WEN, inc. Premium Atlantic Vinyl 8100 Single Hung. for Florida Product Approval FL# FL Report No.

LABORATORY TEST REPORT

EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Originally Issued: 09/10/2015 Revised: 10/12/2017 Valid Through: 09/30/2019

DL-200. Specifications

Not to be distributed outside of FM Approvals and its affiliates except by Customer

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # CHRISTIAN STREET, UNIT 13 OXFORD, CT (203)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT (203)

CONSTRUCTION MATERIALS

Product Evaluation Report of. JELD-WEN, inc. Energy Saver/Contour Wood Edge Opaque Steel Outswing Door w/ or w/o Sidelites


Transcription:

Product Evaluation Report REED S METALS, INC. Perma-Lok, 26 Ga. 16 Coverage Roof Panel over 15/32 Plywood Florida Product Approval # 12725.1 R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Reed s Metals, Inc. 19 E. Lincoln Drive NE Brookhaven, MS 39601 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID: 1920 Validator: Brian Jaks P.E. #70159 Contents: Evaluation Report Pages 1 4

Compliance Statement: Product Description: Panel Material/Standards: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Perma-Lok, 7/8 Nailstrip Roof Panel, 26 Ga. Steel, 16 Coverage, Roof Panel restrained with fasteners into 15/32 APA Plywood decking. Non-structural Application. Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint finish optional. Yield Strength: Min. 50.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3 Panel Dimension(s): Thickness: 0.020 Width: 16 maximum Coverage Female Rib: 7/8 tall Male Rib: ¾ tall rib w/ slotted strip Panel Seam: Snap Lock Panel Rollformer: New Tech Machinery Corp. Panel Fastener: Substrate Description: Through Panel Slot: (1) #10-12 x 1 Pancake Type A ¼ minimum penetration through plywood Corrosion Resistance: Per Florida Building Code 2017, Section 1507.4.4. 15/32 thick, APA Rated plywood. Plywood supports at maximum 24 O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Substrate must be designed in accordance w/ Florida Building Code 2017. Allowable Design Uplift Pressure: Table "A" Maximum Total Uplift Design Pressure: Panel Slot Fastener Spacing: 63.5 psf 5 3/16 O.C. *Design Pressure includes a Safety Factor = 2.0.

Code Compliance: Evaluation Report Scope: Performance Standards: The product described herein has demonstrated compliance with The Florida Building Code 2017, Section 1504.3.2. The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. The product described herein has demonstrated compliance with: UL 580-06 - Test for Uplift Resistance of Roof Assemblies UL 1897-2012 - Uplift Test for Roof Covering Systems Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 101-0193T-09, Dated 03/04/2009 2. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization # ANE ID: 1920) Test Standard Equivalency: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-2012 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity.

Minimum Slope Range: Installation: Underlayment: Roof Panel Fire Classification: Shear Diaphragm: Design Procedure: Minimum Slope shall comply with Florida Building Code 2017, including Sections 1507.4.2 and in accordance with Manufacturers recommendations. Install per manufacturer s recommended details. Per Florida Building Code 2017, Section 1507.1.1 and manufacturer s installation guidelines. Fire classification is not part of this acceptance. Shear diaphragm values are outside the scope of this report. Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading.