What is Conventional Construction?

Similar documents
MAT109: Introduction to the Wood Frame Construction Manual

COPYRIGHT MATERIALS. Wind Solutions - Perforated Wood Structural Panel Shear Walls (DES 416)

Shear Wall Design Examples per 2015 WFCM and 2015 SDPWS

Wood Shear Wall Design Examples For Wind

Structural Design for Wind Loads: An Overview of Engineering Considerations for Wood

2012 Wood Frame Construction Manual: Wind Load Distribution on Buildings Load Paths

WFCM 110 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 100 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

Special Inspections for Wood Construction BCD710 Michelle Kam-Biron, PE, SE, SECB Senior Director, Education American Wood Council

WFCM 120 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 90 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

CALCULATING WIND LOADS ON LOW-RISE STRUCTURES PER 2015 WFCM ENGINEERING PROVISIONS (STD342-1)

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

STD302: Wood Frame Construction Manual 2001 National Edition

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

2012 IRC Wood Wall Bracing

Significant Changes to AWC s Special Design Provisions for Wind and Seismic

Fundamentals of Wood Design and Engineering

Significant 2012 IBC, NDS and 2008 SDPWS Changes

Significant 2012 IBC, NDS and 2008 SDPWS Changes

WFCM WORKBOOK 2012 EDITION. Wood Frame Construction Manual for One- and Two-Family Dwellings

WOODWORKS WEBINAR - JUNE 14, 2012

Wood Frame Construction Manual for One- and Two-Family Dwellings 2015 EDITION WORKBOOK

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

2012 Wood Frame Construction Manual: Wind Speed and Design Pressure Determination According to ASCE 7 10

2001 California Building Code (1997 UBC) -vs California Building Code (2006 IBC)

WFCM WOOD FRAME CONSTRUCTION MANUAL. WOOD FRAME CONSTRUCTION MANUAL for One- and Two-Family Dwellings AMERICAN WOOD COUNCIL

Floor Truss Ribbon Board Load Path. Overview Revised 3/24/2017

Floor Truss Ribbon Board Load Path

ADVANCED FRAMING LUMBER

LVL Product Guide 2.0E LVL 1.5E LVL

U.S. WALL GUIDE. Featuring Trus Joist TimberStrand LSL and Parallam PSL Wall Framing. Engineered to meet code requirements for walls up to 30' tall

APPENDIX A1 WIND AND SEISMIC BRACING GUIDELINE FOR ONE AND TWO FAMILY DWELLINGS AND TOWNHOUSES

PRESENTATION OUTLINE MUBEC & IRC APPLICABILITY & ADMIN. 6/17/2015 RESIDENTIAL STRUCTURAL SYSTEMS. Carmen B. Bombeke, P.E.

City of Bemidji Building Office City Hall 317 4th Street NW Bemidji, Minnesota Phone Fax emi mn s

Considerations for Outof-Plane. Design

INTERIOR SHEAR WALLS. DESIGN AID No.. 8. American Forest & Paper Association. American Wood Council L MAX = 36' 16' 20' Wall C

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: HY-TEK FASTENERS INC. EVALUATION SUBJECT: HY-TEK NAILS

2015 Special Design Provisions for Wind and Seismic Philip Line, P.E., John Buddy Showalter, P.E., Michelle Kam-Biron, P.E., S.E., Jason Smart, P.E.

Method for Increased Buckling Capacity of Built-Up Beams and Columns

RB104-09/10 R602.7, R (New), Table R (New), Figures R (1)-(2) (New)

Version 2.1 IBS 2010 Special Resource Edition

Building Division Informational Handout

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

Impact of C&C loads due to ASCE/SEI Overview Revised 3/23/2017

ROOF FRAMING ANCHORAGE FORCES: MWFRS

Structural Training - Part 1:

Residential Wood Deck Design

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

Lateral load basics Code acceptance of Standard. Standard Overview 2008 Wind & Seismic Standard. Wind. Wind Load Path. IBC Section 1604.

MBOIA IRC Wall Bracing. Mark Halverson. Maine Building Officials and Inspectors Association. First Last

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

North Shore at Canton Baltimore, MD Beau Menard Technical Report 1

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

A. Are Plan Reviews Important? B. Statement of Special Inspections C. Deferred Submittals D. DFCM Requirements

Heel Blocking Requirements and Capacity Analysis. Overview Revised 3/22/2017

Code Compliant Fire- Resistance Design for Wood Construction

Joint Evaluation Report

Chapter 2 EARTHQUAKE-RESISTANCE REQUIREMENTS

Code Compliant Fire Resistance Design for Wood Construction. Paul Coats, PE, CBO Southeast Regional Manager American Wood Council

Joint Evaluation Report

Joint Evaluation Report

Originally Issued: 11/04/2016 Revised: 11/28/2017 Valid Through: 11/30/2018

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Design Guide Revised 11/17/2016

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

Tall Wall Applications Challenges. Products Design Considerations Framing Details Fire Assemblies Innovative Solutions. Residential Construction

TYPICAL BEARING WALL FRAMING Joints in plates must be offset by 24 min.

Stanley Fastening Systems, L.P. Stanley BOSTITCH Pneumatic Pins. TER No

Shaft Wall Solutions for Wood-Frame Structures. Ricky McLain, PE, SE WoodWorks Wood Products Council Boston & Waltham Workshops, December 6 & 7, 2017

Prescriptive and Engineered Design Provisions of the Massachusetts One- and Two-Family Dwelling Code

GENERAL ISSUES AND CONCERNS

2008 Special Design Provisions for Wind and Seismic

City of Republic Community Development Girder and Header Spans for Exterior Walls

International Code Council

Prescriptive Residential Wood Deck Construction Guide with Commentary DCA IRC Version (BCD 306)

SDPWS. Special Design Provisions for Wind & Seismic 2015 EDITION

Featuring Selection and Installation Information for Lateral Wind Loads

A REPORT ON THE EFFECTS OF WIND SPEED ON TIMBER CONSTRUCTION JOSHUA HUENEFELD. B.S., Kansas State University, 2012 A REPORT

Lateral Design of Mid- Rise Wood Structures

Individual Truss Marking Is it a Building Code Requirement?

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

Mid-Rise Engineering Considerations for Engineered Wood Products

Shaft Wall Solutions for Wood-Frame Structures. Ricky McLain, PE, SE WoodWorks Wood Products Council Charlotte WSF, November 2, 2017

This permit is issued under OAR Permits expire if work is not started within 180 days of issuance or if work is suspended for 180 days.

R Code and Commentary for 2012 NC Residential Code final 03/06/13

PER See all Pei ES Listings at: Report Owner Evolutiondeck Inc. 25 Industrial Court B Sault Ste Marie, ON, Canada P6B5Z9

Recommendations on Proposed International Code Changes

research report Cold-Formed Steel Gable End Wall Design Using the Prescriptive Method for One and Two Family Dwellings RESEARCH REPORT RP05-2

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

Copyright Materials. American Wood Council

Framing & Building Basics. Architectural Drawing & Interior Design

ReWall EssentialBoard, NakedBoard & Ceiling Panels TER No

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008

Sponsored by The Boston Association of Structural Engineers and the Structural Engineers Association of Massachusetts

Transcription:

What is Conventional Construction? Copyright This presentation is protected by US and International Copyright laws. Reproduction, distribution, display and use of the presentation without written permission of AWC is prohibited. American Wood Council 2016 2 1

American Wood Council 3 Conventional Construction Prescriptive Requirements Provisions referred to as Conventional Construction IBC contains conventional construction section Most provisions taken from the IRC Two codes similar in some ways and different in others 4 2

Conventional Construction One of 4 design methodologies recognized in 2012 IBC Chapter 23 Time-tested prescriptive framing methods Design primarily for residential construction Permitted to be used without design analysis or load calculations What if NOT using Conventional Construction? 5 Section 2301 National Design Specification Allowable Stress Design/LRFD Standards become part of the code to the prescribed extent of the reference only Editions are specific 2009 IBC references 2005 NDS 2012 IBC reference 2012 NDS 6 3

Section 2301 2012 WFCM Wood Frame Construction Manual 2012 WFCM uses ASCE 7-10 wind design provisions 7 Section 2301.2 2301.2 Standard ICC 400-12 Standard on the Design and Construction of Log Structures 8 4

Conventional Construction One of 4 design methodologies recognized in 2012 IBC Chapter 23 Time-tested prescriptive framing methods Design primarily for residential construction Permitted to be used without design analysis or load calculations 9 Conventional Construction IBC Chapter 2 Definition of conventional light-frame construction A type of construction whose primary structural elements are formed by a system of repetitive wood framing members. 10 5

Conventional Construction IBC Section 2308 - Limited application also defines conventional construction Maximum 3 stories above grade plane Maximum floor-to-floor height of 11-7 Bearing wall height limited to 10 feet Roof spans of 40 ft or less Low-wind only Applies in SDC A E (added requirements for high SDCs) Loads are limited 11 Conventional Construction IBC generally limited to nonresidential IBC 2308 Conventional Framing Dwellings outside scope IRC & nonresidential IRC dwellings Detached one- and two-family dwellings Multiple single-family dwellings (townhouses) < 3-stories Separate means of egress 12 6

Conventional Construction IRC Versions of the term used but not defined IRC Defined by scope of the code 1- & 2-family dwellings Multiple single-family dwellings (townhouses) Limit of 3-stories Low-wind application Loads limited 2012 IRC live/work units Section 419 IBC owner-occupied lodging houses 5 or fewer guest rooms 13 Derived From Generally consistent loading Traditional materials Relatively small structures with Small spans Moderate wall heights Regular floor plans 14 7

Derived From Larger structures which also had Small spans Moderate wall heights Regular floor plans 15 High-Wind Design IBC & IRC: Design wind speed limit of 110 mph (3-second gust) in hurricane-prone areas & 100 mph in others 16 8

High-Wind Design For greater wind loads use Design per ASCE 7 ICC 600, Standard for Residential Construction in High-wind Regions AWC s Wood Frame Construction Manual for One- & Two-Family Dwellings (WFCM) 17 High-Seismic Design Prescriptive limits of Seismic Design IBC and IRC: SDC A, B, C, D 0, D 1, D 2, and E Irregular structures IBC: Not for use in SDC D &E IRC: Not for use in SDC C & D Beyond IRC limits Design using ASCE 7 AWC WFCM 18 9

Design of Portions IRC and IBC 2308 allows use of non-prescriptive elements if those elements are professionally designed 19 IRC & IBC 2308 What It s Not 20 10

Conditions Not Addressed 21 Very Large Buildings Although h there may be some conventional elements 22 11

Heavy Timber Framing 23 Glued Laminated Timbers Not addressed but permitted 24 12

Trusses Design required 25 Engineered Wood Products Design required 26 13

Alterations of EWPs Alterations Prohibited R502.8.2 (floors) R802.7.2 (roofs) Unless specifically permitted Manufacturer s recommendations Professional design 27 And Whatever 28 14

WFCM 2012 Wood Frame Construction Manual & Commentary 29 Code Limitations IBC prescriptive limits (IRC applies in most cases) Wind: 100 mph (3-second gust) in hurricaneprone areas. 110 mph elsewhere Seismic: Seismic Design Categories A - E Snow: 50 psf (ground snow load) IRC prescriptive limits Wind: 100 mph (3-second gust) in hurricane- prone areas. 110 mph elsewhere Seismic: Seismic Design Categories A - E Snow: 70 psf (ground snow load) 30 15

ASCE 7 Wind Speeds 31 Code References IRC Section R301.1.1 Accepted as an alternate to formal design for snow, wind, and seismic loading IRC Section R301.2.1.1 & Figure R301.2(4)B Accepted as one of several wind design criteria 32 16

Background 1995 Edition Initially referenced by Standard Building Code Based on SBC low-rise wind provisions Addressed wind loading only Referenced in 2000 editions of IBC & IRC 2001 Edition Based on IBC loads Wind, seismic & snow loading Referenced in 2009 IBC & IRC 2012 Edition Referenced in 2012 codes 33 Scope 1- & 2-family dwellings Maximum 3 stories Roughly rectangular shape Anything outside of this scope requires acceptable engineering practice 34 17

Scope: Design Loads Systems sized using IBC load provisions Loads Ground snow: 0 70 psf Wind: 85 150 mph (3-second gust) Seismic: Seismic Design Categories A - D 35 Scope: Building Dimensions MEAN ROOF HEIGHT = 33 Wind design: Exposure B MRH adjustments for other exposures h r h r /2 MRH G G/2 36 18

Scope: Building Dimensions W Max. 80 Max. 80 L Span Span L W Minimum L/W = 1:4 ASPECT RATIO & BUILDING DIMENSIONS Maximum L/W = 4:1 37 Scope: Floor Systems Sheathing Offset d f d Connect as req d to transfer shear in both directions Cut sheathing for connector installation Band joist Blocking VERTICAL FLOOR OFFSET FIGURE 2.1i 38 19

Scope: Floor Systems L2 L1 Joist/rafter span L2/L1 4 FLOOR & ROOF DIAPHRAGM ASPECT RATIO LIMITS 39 Scope: Floor Systems L2 O2 Lesser of 12 ft or L2/2 Joist/rafter span L1 O1 Lesser of 12 ft or L1/2 FLOOR & ROOF DIAPHRAGM ASPECT RATIO LIMITS 40 20

Scope: Wall Systems Shearwall Maximum 4 offset SHEARWALL LINE OFFSET 41 Scope: Wall Systems Bldg 2 Bldg 1 Bldg 1 Bldg 3 OFFSETS > 4 SEPARATE STRUCTURES Bldg 2 Bldg 1 INSCRIBED STRUCTURES Bldg 1 Bldg 3 42 21

Scope: Wall Systems SHEARWALL STORY OFFSET FIGURE 2.1d Story offset d Shearwall Floor joist d Blocking Shearwall 43 Scope: Wall Systems L H/L 3-1/2 H SHEARWALL SEGMENT ASPECT RATIO LIMITS 44 22

Organization WFCM Commentary bound separately 45 Organization: General Information WFCM Table 1 Applicability Limitations 46 23

WFCM Chapter 2: Engineered Provides loads for floor/wall/roof systems Permits building designer to engineer various building elements using same criteria as used in Prescriptive Design section Information provided in tables and figures Includes provisions for use of wood I-joists & parallel cord trusses Commentary provides explanation of how loads were derived 47 WFCM Chapter 2: Engineered 48 24

WFCM Chapter 2: Engineered 49 Organization: Prescriptive Design Prescriptive building element design Information in tables & figures For building elements that don t fit into prescriptive provisions design using Engineered Design section Commentary provides guidance in how the prescriptive solutions were derived Wind design based on Exposure B but there is an additional section for Exposure C Slightly more conservative, but simpler to follow 50 25

WFCM Chapter 3: Prescriptive Example: Headers and supporting studs 36 30 psf ground snow load 115 mph wind speed (3-sec. gust), Exposure B building width 36 feet header span of 4-0 Is a 2-ply 2x10 header adequate? Required number of jack studs? Header - exterior load bearing wall header supporting roof, ceiling, and two center bearing floors 51 WFCM Chapter 3: Prescriptive 52 26

WFCM Chapter 3: Prescriptive Is a 2-ply 2x10 header adequate for gravity? 36 Yes. 2-ply 2x10 span is 4-2 > 4-0 (from Table 3.22D1 dropped header) Yes. 2-ply 2x10 span is 4-4 > 4-0 (from Table 3.22D2 raised header) Header - exterior load bearing wall header supporting roof, ceiling, and two center bearing floors 53 WFCM Chapter 3: Prescriptive Underlying calc s for gravity Dead load Unbalanced snow D + 0.75 Floor Live + 0.75 Snow combination controls unbalanced snow controls, load = 1,712 plf (WFCM Table 2.11) raised header C L factor = 1.0 (per NDS) Floor dead and Live load dropped header C L factor = 0.86 (per NDS) Floor dead and Live load Header Dropped header lateral torsional buckling example 54 27

WFCM Chapter 3: Prescriptive Are 2 jack studs on each end adequate? Yes 2 jack studs required at each end (from WFCM Table 3.22F) 55 WFCM Changes White paper major changes from 2001 edition summarized http://www.awc.org/pdf/2012-wfcm-changes-web.pdf 56 28

WFCM Addendum 2013 Addendum (May 2013) revised span tables to account for Southern Pine design value changes http://www.awc.org/publications/update/2012wfcm-addendum-may2013.pdf 57 WFCM Availability 58 29

EVALUATION SERVICE REPORTS INTERNATIONAL STAPLE NAIL AND TOOL ASSOCIATION or ISANTA ESR-1539 Dictates fastener equivalency to 16d, 12d, 10d, 8d, Common or Box, regular or pneumatic nails, etc. WFCM states Common Sizes (16d=0.162 diameter x 3.5 5 ) Make sure you are aware of what you, your carpenters, & your subcontractors are using! 59 AWC Field Staff 60 30

Code Official Connections Program Direct access to AWC information and technical support Ongoing information through WoodPost Inform Code Officials regarding information, developments, and advances in the wood industry Information regarding ICC approved AWC continuing education training events, seminars, and webinars 61 Code Official Connections Benefits No cost to qualifying participants Code Officials Inspectors Plans Examiners Free electronic AWC technical publication Discounted publications One free WoodWorks access per department WoodPost bi-weekly e-newsletter Free Online Tools and updates Free continuing education ICC Preferred Provider National Council of Structural Engineers Association American Institute of Architects 62 31

Code Official Connections Contact John Catlett, MCP Code Development Manager 202.463.2708 jcatlett@awc.org Or sign up at: http://awc.org/codeconnections 63 Questions? www.awc.org info@awc.org 64 32