Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

Similar documents
Lateral System Analysis and Confirmation Design November 15, 2004

Structural Redesign Gravity System

[TECHNICAL REPORT 3] Lateral System Analysis

North Shore at Canton Baltimore, MD Beau Menard Technical Report 1

OVERALL STRUCTURAL SYSTEM

David A. Walenga Technical Assignment #1

Brent Ellmann Structural Option 200 Minuteman Park, Andover, MA Structural Consultant: Dr. Hanagan

Project. San Jose City College Physical Education Building. Prepared For. Prepared By PLACE IMAGE HERE. Ken Bauer, AIA Principal

Table of Contents 2. Structural Systems.4 Foundations.4 Floor System...4 Columns..5 Lateral System...5

TECHNICAL REPORT 1. Structural Concepts / Structural Existing Conditions. Penn State Hershey Medical Center Children s Hospital. Hershey, Pennsylvania

Temecula Medical Center Temecula, CA

MOUNTAIN STATE BLUE CROSS BLUE SHIELD HEADQUARTERS

William W. Wilkins Professional Building Columbus, Ohio

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

OF THREE NEW BUILDINGS BEING CONSTRUCTED TO REPLACE THE EXISTING COMPLEX. THE FLOOR SYSTEM OF GEORGE READ HALL IS A HAMBRO COMPOSITE SYSTEM

Technical Report 1. Seneca Allegany Casino Hotel Addition. Salamanca, NY

Kaleida Health Global Heart and Vascular Institute University at Buffalo CTRC/Incubator. Buffalo, New York. Technical Report #2

Jackson Crossing Located in Alexandria, VA. Technical Report 1 Michael Bologna

Structural Design Engineers 120 Montgomery Street, Suite 1410 San Francisco, California / Fax 415/

Lateral System Analysis and Confirmation Design

Visteon Village Corporate Center

Hyatt Place North Shore. Pittsburgh, PA T. Technical Assignment #1. Kyle Tennant. Kyle Tenn. Structural (IP) [Type the document subtitle]

Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8

GEN*NY*SIS CENTER FOR EXCELLENCE IN CANCER GENOMICS Rensselaer, NY

LIFE SCIENCES BUILDING STRUCTURAL CONCEPTS AND EXISTING CONDITIONS

Xyston Inn. NY. Proposal. Xiaodong Jiang. Structure Option. Advisor: Dr. Linda Hanagan

Technical Assignment 3 December 3, 2007

Structural Technical Report I October 5, 2006 Structural Concepts / Structural Existing Conditions Report

STRUCTURAL TECHNICAL REPORT 1

Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Building B

Technical Report #2. Matthew R Peyton

Rutgers University Law School Building Addition and Renovation Camden, NJ

Brent Ellmann Structural Option 200 Minuteman Park, Andover, MA Structural Consultant: Dr. Hanagan

CORPORATE HEADQUARTERS

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

Xyston Inn. NY. Proposal. Xiaodong Jiang. Structure Option. Advisor: Dr. Linda Hanagan

Southwest Housing, Arizona State University

Structural Technical Report 1 Structural Concepts / Existing Conditions

Point Pleasant Apartments Point Pleasant, NJ Ryan P. Flynn Structural Option Faculty Consultant: Dr. Hanagan

Technical Report 1. Kingstowne Section 36A 5680 King Center Drive Kingstowne, VA James Chavanic. Structural Option. Advisor: Dr.

CORPORATE HEADQUARTERS

Earth and Engineering Sciences Building University Park, Pennsylvania

Technical Report 1. Hakuna Resort Swift Water, Pennsylvania. Image Courtesy of LMN Development LLC

Crossroads at Westfields Building II

HIGH RISE CONDO SOHO, NEW YORK, NY

Structural Technical Report 1 Structural Concepts/ Structural Existing Conditions Report

Thesis Proposal Structural Redesign / Cost, Schedule and Coordination Analysis / Architectural Impact

Boyds Bear Country Pigeon Forge, TN

Campus Square Buildings C & D Lehigh University, Bethlehem, PA

Caitlin Ferrell Structural Option Dr. Boothby, AE Faculty Consultant. Erie Convention Center and Sheraton Hotel

Hilton Baltimore Convention Center Hotel Western Podium

Hershey Research Park Building One. Technical Report 2. Jonathan Krepps Structural Option Advisor: Dr. Hanagan 10/12/12

Structural Technical Report 1 Structural Concepts / Structural Existing Conditions Report

The Structural Redesign of Boyds Bear Country and its Related Systems. Boyds Bear Country, Pigeon Forge, Tennessee

1000 CONTINENTAL SQUARE

Technical Report #1. Indiana Regional Medical Center Indiana, PA. Cody A. Scheller. Structural Concepts & Existing Conditions Report

111 MORGAN ST. Ryan Friis

Pro-Con Structural Study of Alternate Floor Systems

Thesis Proposal 12/13/06

Danielle Shetler - Structural option Courtyard by Marriott Lancaster, PA

Dead Loads (psf): Concrete Floor Slab on Metal Deck 45 psf Mechanical and Ceiling 7 psf Miscellaneous 5 psf Exterior Wall 80 psf

Alexis Pacella Structural Option Dr. Schneider Lexington II, Washington D.C. Technical Report #3 November 21,

Handley McDonald. Handley McDonald. Technical Report 1. Claude Moore Medical Education Building Faculty Advisor: Richard Behr

1000 CONNECTICUT AVENUE

Best Buy Corporate Building D (4) Richfield, MN

Simplified Building Schematic for Typical Floor (Levels 9 through 22):

Structural Analysis and Redesign of Lynde and Harry Bradley School of Technology & Trade Milwaukee, Wisconsin

Thesis Proposal. Piez Hall Extension. Oswego, NY

Global Village Rochester Institute of Technology Rochester, New York

Hilton Baltimore Convention Center Hotel Western Podium

Thesis Proposal. Matthew R Peyton

Pro-Con Structural Study for Alternative Floor Systems October 27, 2004

House of Sweden. Structural Study of Alternative Floor Systems K St. NW Washington, DC 20007

Structural Concepts and Existing Conditions Report

Letter of Transmittal

Simplified Building Schematic for Typical Floor (Levels 9 through 22):

Third Avenue New York, NY. Structural Concepts/ Structural Existing Conditions Report September 30, Michelle L.

Brent Ellmann Structural Option 200 Minuteman Park, Andover, MA Structural Consultant: Dr. Hanagan

Technical Report 1 Bed Tower Addition at Appleton Medical Center Appleton, WI

Technical Assignment #3 November 15, 2004 Lateral System Analysis and Confirmation Design

Structural Technical Report #2 Pro/Con Study of Alternate Floor Systems

Thesis Proposal. La Jolla Commons Phase II Office Tower San Diego, California. December 13, 2013

John Jay College Expansion Project

North Mountain IMS Medical Office Building

TECHNICAL REPORT III LATERAL STRUCTURAL SYSTEM ANALYSIS

90% Design Submittal Structural Calculations Parking Garage CDRL

Jonathan R. Torch Technical Report 2 Columbia University. Technical Report 2. Pro-Con Structural Study of Alternate Floor Systems

Hyatt Place North Shore. Pittsburgh, PA T. Technical Assignment #2. Kyle Tennant. Kyle Tenn. Structural (IP) [Type the document subtitle]

Technical Report #1. Matthew R Peyton

THE FORENSIC MEDICAL CENTER

MOUNTAIN STATE BLUE CROSS BLUE SHIELD HEADQUARTERS

Statement of Special Inspections

Building Division Informational Handout

UNION STATION EXPANSION AND RESTORATION TECHNICAL REPORT I

These systems are evaluated on the basis of serviceability issues such as:

Existing Conditions Report

Technical Report #3. Matthew R Peyton

Attachment A. USG Minimum Design and Construction Requirements for Wood Framed Structures

200 Minuteman Drive. New Design for Additional Floors and Vibration Sensitive Equipment. Brent Ellmann. Structural Option

STEEL STRUCTURAL SYSTEMS

Transcription:

System Codes and Criteria Design Codes and Standards The design code used is the Wisconsin Administrative Code along with the State of Wisconsin Department of Commerce-Safety & Buildings Chapters Comm 50-64 and the City of Milwaukee Code of Ordinances Chapter 257-Schools. General ACI, ASCE 7, and AISC codes have been followed and interpreted by the engineers and designs fully comply with nationally accepted standards. Load combinations and safety factors were fully analyzed and included in the final design of the building. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Columns min cover 1 1/2 Girders & Beams min cover 1 1/2 Joists min cover 1 1/2 min web 4 top slab 5 Walls min cover 3/4 Slabs min cover 3/4 min thickness 5 Geotechnical Report Allowable Bearing Capacity 5000 PSF Min wall footing = 2-0 Min column footing = 3-0 Footing bearing depth = 4-0 min below exterior grade Typical spread and strip footings are recommended Max Settlement = 1 Max differential settlement = 3/4 Below Grade Walls: γ= 135 pcf Friction factor (worst case) Ka = 0.42 Kp = 2.66 Ko = 0.59 Design Pressure 57 PCF 359 PCF 80 PCF Jonathan Hill 8

Materials Cast-in-Place Concrete F c = 4000 PSI at 28 days F c = 5000 PSI at 28 days Concrete Masonry Units ASTM C90 Type N-1 Masonry Core Fill F c = 3000 PSI at 28 days Reinforcing Bars ASTM A615 (Grade 60) Welded Bars and Anchors ASTM A706 (Grade 60) Welded Wire Fabric ASTM A185 Keydeck Mesh, No. 2160-2-1619 ASTM A82 Steel Fibers 1 1/2 ASTM A820 Steel WF Beams and Columns Cellular Beams Other Shapes and Plates Square or Rectangular Tubes Round Tubes Bolts Anchor Bolts Expansion Bolts Headed Shear Connector Studs Epoxy Anchors ASTM A572 (Grade 50 - Fy = 50ksi) ASTM A572 (Grade 50 - Fy = 50ksi) ASTM A36 (Fy = 36 ksi) ASTM A500 (Grade B - Fy = 46 ksi) ASTM A500 (Grade B - Fy = 42 ksi) ASTM A325N ASTM A307 or ASTM A36 KWICK-Bolts, WEJ-IT Bolts, or Red-Head Anchors ASTM A108 Hilti HIT HY150 Gravity System Floor Loads The following is a summary of the floor loads acting on the structure. The building is divided into many areas each with a different purpose and therefore different loading conditions occur. The Wisconsin Administrative Code was referred to and used as a guideline for many of the live load calculations. Dead loads were calculated using material self-weight and standards used by Hammel, Green & Abrahamson, Inc. Detailed calculations, load combinations, and live load reductions have been analyzed and are available in Appendix A. First Floor Laboratory Live Load: 150 PSF (floor load) 50 PSF (mech below) 200 PSF 140 PSF (30 pan & joist) Jonathan Hill 9

Typical Laboratory Floor Live Load Typical Classroom Floor Live Load Administration Floor Live Loads Bar Joist w/ Flat Roof Snow Load 125 PSF (floor load) 150 PSF 105 PSF (53 pan & joist) 80 PSF (floor load) 105 PSF 105 PSF (53 pan & joist) 80 PSF (floor load) 105 PSF 150 PSF (library) 175 PSF 170 PSF (bookstore/vault) 195 PSF 125 PSF (main corridor) 150 PSF 105 PSF (53 pan & joist) 30 PSF with applicable drift 4 PSF (bar joists) 6 PSF (4 rigid insulation) 3 PSF (metal roof deck) 12 PSF (roofing & ballast) 30 PSF Jonathan Hill 10

Curved Roof over Laboratories Snow Load 30 PSF with applicable drift 8 PSF (beams & girders) 3 PSF (metal roof deck) 8 PSF (roofing & insulation) 6 PSF (ceiling/misc/mech) 25 PSF Wall Loads All wall loads are taken as industry or company standards and reflect the selfweight of the material and or systems. Interior Partitions 20 PSF (min) Exterior CMU w/ Brick Veneer 4 Brick 50 PSF 8 CMU 50 PSF 100 PSF Curtainwall / Metal Panel System 20 PSF Snow Loads Based on the Wisconsin Building Code snow loads were calculated and compared to company standards. Several areas of drift will occur along the building, mainly on canopies, roof projections and along the two story section of the building where it meets the four story section. The snow drift along the two different roof levels has been calculated in detail and summarized in Figure 1 below. Figure 1: Snow Drift Jonathan Hill 11

Cast-in-Place Pan and Joist System The majority of the building is designed using a cast-in-place concrete pan and joist system. Due to the need of a large floor-to-floor height and the possibility of exposed structure, the concrete system was the best choice for the main structural system. The code used for reinforced concrete design and construction was ACI 318-89. Foundation The foundation system consists of a combination of stepped, continuous and spread footings. The basement foundation, which occurs only in Area C, resembles the on-grade foundation only differing with the height of its loadbearing walls. Footings have been designed for a maximum soil bearing pressure of 5000 PSF. Continuous footings typically have thicknesses between 2-0 and 2-6 and foundation walls are typically 1-4 thick and centered on the footings. Columns Concrete columns carry most of the building load, with only a few scattered steel pieces to support the flat roof and canopies. They are supported by spread footings and are evenly distributed throughout the floors. Column sizes range from 16 to 24 inch squares. Framing The pan and joist system typically consists of a 20 pan depth and a 5 slab for a total depth of 25. Joists have a common width of 5. This system is used consistently throughout the building and adjustments in pan width occur where necessary. A typical bay is generally around 32-0 x 30-0 in size and joists are called out, as well as the pan width for each individual bay. A simplified floor layout is shown in Figure 2. Figure 2: Typical Framing Jonathan Hill 12

Roof System With the majority of the building loads being taken by the concrete system, steel was used for specialized cases. These cases include elaborate canopies, a standard steel joist supported roof, and a long-spanning barrel roof, which is what makes this building so unique. The designs of these steel systems follow the latest AISC manual and specifications. Canopies Along the exterior of the building steel tubes and channels make up several canopies that are supported by the arching roof trusses. These framing members are cantilevered off the concrete columns and secured by a tension rod that connects to a main roof support. The canopies are finished off with a steel roof deck. Figure 3 displays a section of a typical canopy. Figure 3: Canopy Detail Steel Joist Roof The roof frame consists of w-shape girders and evenly spaced Smartbeams. The original design called out for standard open web steel joists; however, Smartbeams were used to provide the same architectural features for a fraction of the price. The webs of standard w-shape beams were cut in a zigzag fashion and then offset and welded back together, providing even greater strength due to the increase in web depth. Jonathan Hill 13

Barrel Vault Roof This is a complex system that integrates steel columns and joists to create an impressing arching roof. The main spanning members are steel purlins that reach over 100 feet. They extend from one exterior steel column to a concrete pier on the other side of the building. The purlins are attached to steel tubes that are supported by perpendicular spanning trusses. Steel wire is used for additional stability for the long spanning members. A detailed section of the vaulted roof is shown in Figure 4 below. Lateral System Figure 4: Vaulted Roof Detail Wind Loads The wind loads on this building were calculated using ASCE 7-02 methods. A 90mph worst case wind was applied to the building with an exposure factor of B. Since the building is below 60 feet in height a low-rise approach could have been taken. However, due to the minimal effect on the wind pressures, the standard analysis was done. The original design did not use the now accepted ASCE analysis methods, however for comparison purposes the wind loads were updated and analyzed. Seismic Loads In the original design no seismic loads were accounted for. The analysis took place before any standards or codes were issued that dealt with seismic forces in areas where seismic activity is unlikely. To adhere to modern code, the seismic shear forces have been calculated and distributed to the lateral system for analysis. Jonathan Hill 14

Lateral Framing System As mentioned before, the main supporting system of this building is a cast-inplace concrete frame. This being so, nearly all columns and intersecting beams take part in the lateral system and the simply laid out concrete frames carry the loads. However, when analyzing the barrel vault roof, the lateral system becomes a bit more complicated. Steel roof members transfer the lateral loads directly to the concrete beams using a bent plate which is embedded in the beams using expansion bolts. At the other end of the vault roof the steel joists transfer their lateral load into a steel tube column, again using a bent plate, which then distributes the load to its supporting concrete beam. The concrete columns cantilever up to the steel roof joists eliminating any need for moment frames or cross bracing within the steel members; therefore, all steel connections are kept simple and transfer only minimal lateral forces. Once the lateral loads are absorbed by the concrete framing system they are transferred to the foundations. The load path taken in this monolithic system can be seen in the building section below. Figure 5: Lateral System Section Jonathan Hill 15