Keywords: Composite Beam, Friction contribution to horizontal shear connection, flexible connectors.

Similar documents
INFLUENCE OF THE FRICTION AT THE SUPPORT IN THE LONGITUDINAL SHEAR STRENGHT OF COMPOSITE SLAB

Numerical modeling of steel-concrete composite beams. Modelagem numérica de vigas mistas aço-concreto

Reinforced concrete waffle flat slabs under shearing

GFRP-GLULAM-CONCRETE COMPOSITE BEAMS: AN EXPERIMENTAL EVALUATION

About the use of semi-continuity to remove fireproof coatings in simply supported composite steel and concrete beams

Lajes lisas nervuradas bidirecionais com furos

THE CONTRIBUTION OF FLANGES TO WALLS UNDER THE ACTION OF THE ARCHING EFFECT

Experimental study of the influence of friction at the supports on longitudinal shear resistance of composite slabs

Nonlinear Finite Element Analysis of Composite Cantilever Beam with External Prestressing

Keywords Railway Bridge; Monitoring Stress; Fatigue, F.E.M.

EXPERIMENTAL ANALYSIS OF MECHANICAL BEHAVIOR OF LINTELS IN STRUCTURAL MASONRY

A Study on the Effect of Shear Connectors in Composite Beams

COMPOSITE WOOD-STEEL STRUCTURES: STRESS ANALYSIS

Partially Restrained Beam-Column Connections in Reinforced Concrete Structures

Structural Characteristics of New Composite Girder Bridge Using Rolled Steel H-Section

Encased Beam with Variable Upper Steel Flange Position

ANALYSIS OF THE CONTRIBUTION OF MASONRY INFILL IN THE OVERALL STIFFNESS OF CONCRETE FRAMES

Finite Element Modeling of New Composite Floors Having Cold-Formed Steel and Concrete Slab

Strength of Non-Prismatic Composite Self-Compacting Concrete Steel Girders

Chapter 7. Finite Elements Model and Results

NUMERICAL MODELLING OF REINFORCEMENT OF CONCRETE COLUMNS BY JACKETING

Punching shear resistance of reinforced concrete slabs under pneumatic loads

ARTICLE IN PRESS. Thin-Walled Structures

Lateral stability of two-floor wooden house

BUCKLING OF STEEL AND COMPOSITE STEEL AND CONCRETE COLUMNS IN CASE OF FIRE

Pullout Strength of Axially Loaded Steel Rods Bonded in Glulam at a 45 Angle to the Grain

Numerical and Experimental Study of Steel Space Truss with Stamped Connection

Development of timber concrete composite bridge decks in Brazil

Level 6 Graduate Diploma in Engineering Structural analysis

Topology Optimization of Reinforced Concrete Plane Frames

On the Behaviour of Single-Span Steel Beams Under Uniform Heating

Torsion in tridimensional composite truss bridge decks

CHAPTER 1 INTRODUCTION

Glulam-concrete composite structures: experimental investigation into the connection system

Nonlinear Analysis of Shear Dominant Prestressed Concrete Beams using ANSYS

Numerical Modeling of Innovative Connection Between RC Beam and Steel Column

VACUUM FORMED GFRP PROFILES USED AS EXTERNAL REINFORCEMENT IN DAMAGED CONCRETE SCTRUCTURES LOW COST APPROACH

STABILITY AND DUCTILITY OF CASTELLATED COMPOSITE BEAMS SUBJECTED TO HOGGING BENDING

UHPC Connection of Precast Bridge Deck

Nonlinear Models of Reinforced and Post-tensioned Concrete Beams

Non Linear Analysis of Composite Beam Slab Junction with Shear Connectors using Ansys.16

3.4.2 DESIGN CONSIDERATIONS

NONLINEAR FINITE ELEMENT ANALYSIS OF SHALLOW REINFORCED CONCRETE BEAMS USING SOLID65 ELEMENT

REAL SCALE EXPERIMENTAL ANALYSES OF CIRCULAR HOLLOW SECTION MULTI-PLANAR STEEL TRUSSES

A COMPOSITE FLOOR TRUSS TOP CHORD USING CONCRETE-FILLED STEEL TUBE (CFST)

Reinforced concrete bridge pier ductility analysis for different levels of detailing

Analysis of slim floor beams in fire: emphasis on the concrete constitutive models

NEW COMPOSITE CONSTRUCTION OF HYBRID BEAMS COMBINING STEEL INVERTED T-SECTION AND RC FLANGE

Demountable Shear Connectors for Sustainable Composite Construction

AN INVESTIGATION OF SEISMIC RETROFIT OF COLUMNS IN BUILDINGS USING CONCRETE JACKET

Study on Minimum Shear Reinforcement of Reinforced Concrete Flat Slabs

VIBRATION ANALYSIS OF AN OIL PRODUCTION PLATFORM

ANALYTICAL STUDY OF PUNCHING SHEAR ON WAFFLE SLAB WITH DIFFERENT RIB SIZES

Keywords: steel structures, cold-formed steel angles, structural stability, numerical analysis, non-linear analysis.

Experimental study on the seismic performance of RC moment resisting frames with precast-prestressed floor units.

THEORETICAL AND EXPERIMENTAL ANALYSIS OF STEEL SPACE- TRUSS WITH STAMPED CONNECTION

Numerical Modelling of Shear Connections for Composite Slabs

The Effect of Axial Force on the Behavior of Flush End-Plate Moment Connections

Effect of Flange Width on Flexural Behavior of Reinforced Concrete T-Beam

Strain and Stress Distributions in Composite Deck Slabs: A Numerical Study

Flexibility modeling of reinforced concrete concentric frame joints. Modelação da flexibilidade de nós concêntricos de pórticos em concreto armado

Flexibility modeling of reinforced concrete concentric frame joints. Modelação da flexibilidade de nós concêntricos de pórticos em concreto armado

Experimental study on the flexural behavior of largescale rectangular concrete-filled steel tubular beams

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 1, 2012

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

The semi-rigid behaviour of column bases influences the structural frame response and in particular:

Scientific Seminar Design of Steel and Timber Structures SPbU, May 21, 2015

Project of a residential building in seismic zone

CHAPTER 5 FINITE ELEMENT MODELLING

Behaviour of UHPFRC-RC composite beams subjected to combined bending and shear

PERFORMANCE OF AN INNOVATIVE PRE-CAST COLD-FORMED STEEL AS COMPOSITE BEAM WITH SINGLE AND DOUBLE C- CHANNELS

Nonlinear Finite Element Analysis of the Steel-concrete Composite Beam to Concrete-filled Steel Tubular Column Joints

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

PARTIAL COMPOSITE ACTION IN SC COMPOSITE WALLS FO NUCLEAR STRUCTURES

SEISMIC RESPONSE OF LINEAR, FLANGED, AND CONFINED MASONRY SHEAR WALLS

CHAPTER 7 FINITE ELEMENT ANALYSIS

TRIDIMENSIONAL ANALYSIS OF TALL BUILDINGS IN MASONRY STRUCTURES. Palacio, K. (1) e Silva, R.M. (2)

FIRE PERFORMANCE OF AN UNPROTECTED COMPOSITE BEAM Behavior with finite beam end restraints, rebar size and locations

Behavior and Strength of Slab-Edge Beam-Column Connections under Shear Force and Moment

Long-term Experiments of Composite Steel-Concrete Beams

CREEP TESTS OF DRY AND SATURED CLAY BLOCK PRISMS

composite elements, lateral loads, strain analysis, behavior Composite steel concrete elements made by steel and concrete are used in world wide almos

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

3D analysis of solid reinforced concrete beams subjected to combined load of bending, torsion and shear

Numerical and Experimental Behaviour of Moment Resisting Connections using Blind Bolts within CFSHS columns

Seismic performance of New Steel Concrete Composite Beam-Columns

Numerical Analysis and Experimental Studies on Welded Joint for Buildings

Fire Behaviour of Long Span Composite Floor

SEISMIC BEHAVIOR AND DESIGN OF STEEL SHEAR CONNECTIONS WITH FLOOR SLABS

Finite Element Investigation on Load Carrying Capacity of Corroded RC Beam Based on Bond-Slip

Various Types of Shear Connectors in Composite Structures

Effect of Geometry of Vertical Rib Plate on Cyclic Behavior of Steel Beam to Built-up Box Column Moment Connection

Ultimate flexural strength of prestressed concrete beams: validation and model error evaluation

Journal of Constructional Steel Research

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

CHAPTER 7 ANALYTICAL PROGRAMME USING ABAQUS

Finite Elements Modeling and Analysis of Double Skin Composite Plates

Modal-spectral analysis of a gas storage tank.

Modelling of RC moment resisting frames with precast-prestressed flooring system

ST7008 PRESTRESSED CONCRETE

Transcription:

Gilson Queiroz et al. Civil Engineering Engenharia Civil Estimation of friction contribution in the behaviour of steel-concrete composite beams with flexible shear connectors Gilson Queiroz Dr. Mechanical Engineering, Universidade Federal de Minas Gerais, Dept. of Structural Engineering Belo Horizonte Minas Gerais - Brazil gilson@dees.ufmg.br Hermes Carvalho Msc. Mechanical Engineering, Universidade Federal de Minas Gerais, Dept. of Structural Engineering Belo Horizonte Minas Gerais - Brazil hermesc2000@yahoo.com.br Francisco Rodrigues Dr. Civil Engineering, Universidade Federal de Minas Gerais, Dept. of Structural Engineering Belo Horizonte Minas Gerais - Brazil francisco@dees.ufmg.br Michèle Pfeil Dr. Civil Engineering, Instituto COPPE, Civil Engineering Program Rio de Janeiro RJ - Brazil mpfeil@coc.ufrj.br Avaliação da contribuição do atrito no comportamento de vigas mistas aço-concreto com conectores de cisalhamento flexíveis Abstract A shear connector, developed to be applied to a composite beam whose steel profile is a thin-walled box profile, displayed much greater flexibility than the conventional welded shear connector, leading to particular issues in the composite beam behaviour. One of these issues is the role played by friction at the interface between the steel profile and the slab which, under particular circumstances, may be relevant for serviceability limit states and also for ultimate limit states. The Brazilian and American Standards do not yet recognize the friction contribution in the behaviour of composite beams, though they recognize this contribution in composite slabs. This paper presents the experimental tests carried out with and without friction contribution on simple supported composite beams with flexible connectors and the numerical models developed to simulate the behaviour of the tested beams. The experimental tests revealed significant increases in strength and stiffness of the composite beam due to friction contribution and the comparisons between numerical and experimental results displayed good correlations. Keywords: Composite Beam, Friction contribution to horizontal shear connection, flexible connectors. Resumo Um conector de cisalhamento desenvolvido na UFMG, para uma viga mista de aço-concreto, composta por um perfil metálico de parede fina, apresentou comportamento muito mais flexível do que um conector convencional soldado. Devido a essa flexibilidade, o papel desempenhado pelo atrito na interface do perfil metálico com a laje de concreto pode se tornar relevante sob certas condições, tanto para os estados- limites de serviço como para os estados-limites últimos. As disposições normativas brasileiras e norte-americanas ainda não reconhecem a contribuição do atrito no comportamento de vigas mistas, apesar de reconhecerem essa contribuição em lajes mistas. Este trabalho apresenta os testes experimentais realizados com e sem a presença de atrito em vigas mistas simplesmente apoiadas com conectores flexíveis e os modelos numéricos desenvolvidos para simular o comportamento dessas vigas. Os resultados experimentais mostraram acréscimos significativos da resistência e da rigidez das vigas devidos à presença do atrito na interface concreto-aço. As comparações entre resultados experimentais e teórico-numéricos em termos de deslocamentos verticais para cargas crescentes mostraram boas correlações. Palavras-chave: vigas mistas, atrito na interface entre laje e perfil, conectores flexíveis. REM: R. Esc. Minas, Ouro Preto, 67(3), 253-258, jul. sep. 2014 253

Estimation of friction contribution in the behavior of steel-concrete composite beams with flexible shear connectors 1. Flexible shear connector for cold formed profile and friction contribution The use of cold-formed profile (CFP) in Brazil s construction industry has increased not only for applications on secondary members such as purlins and space covering members for roofs and walls but also on primary components, such as building floor beams. Figure 1 shows a composite beam cross section in which the steel section is composed of a box CFP and the slab is also a composite member formed by the profile sheeting and concrete (steel deck with ribs perpendicular to the steel box profile). The used shear connector combines a rivet with an internal thread driven in the plate hole and a high-strength bolt, as illustrated in Figure 2. This connector was innovatively adopted as a composite beam shear connector in order to avoid the application of traditional welded connectors to the thin-walled CFP while allowing a simple and practical installation procedure. Due to plate bearing plastic deformation (and hole ovalization) this shear connection revealed a much greater flexibility than a conventional connection with welded shear connector (BREMER, 2007), leading to particular issues in the composite beam behavior. One of these issues is the role played by friction at the interface between the steel profile and the slab which motivated a series of analytical, numerical and experimental studies developed at the Federal University of Minas Gerais, Brazil. The strength and the stiffness of the connection between concrete slab and steel profile in composite beams depend basically on the number of shear connectors encased in concrete and their properties. In the case of flexible shear connectors the contribution of friction between the slab and the steel profile may be relevant for serviceability limit states and also for ultimate limit states, provided that the beam span is relatively short and the 875 mm slab stiffness is relatively large compared to that of the steel profile alone. These conclusions were drawn from previous analytical and numerical models allowing for the shear connectors flexibility and friction between the slab and the steel profile (SILVA, 2009, QUEIROZ et al., 2009, OLIVEIRA, 2009, QUEIROZ et al., 2010). These results have not yet been included into the provisions of Brazilian (ABNT, 2008) and American Standards (AISC,2005) which do not recognize the friction contribution in the behavior of composite beams, only of composite slabs. This paper presents the experimental tests carried out to verify the role played by friction at the interface slab steel profile in the behaviour of simple supported composite beam with flexible shear connectors. Also presented are numerical models developed to simulate the tested beams behavior whose results are compared to the corresponding experimental ones. 125 175 80 130 M12 bolt Figure 1 Composite beam cross section showing the box cold-formed profile (CFP), the steel deck slab with ribs perpendicular to the steel section and the shear connectors. (a) (b) Figure 2 Shear connector. (a) high-strength bolt, (b) rivet with internal thread. 2. Experimental analysis 2.1 Models description Aiming to estimate the friction contribution in the composite beam behavior the models for the experimental analysis were conceived on the basis of the conclusions drawn from previous studies (see section 1) with the following characteristics: short span equal to 3.5m 254 REM: R. Esc. Minas, Ouro Preto, 67(3), 253-258, jul. sep. 2014 and flexible shear connectors. The beam model cross-section is illustrated in Fig.1. The box section profile is formed from a 2mm thick SAC300 steel plate (f y =300MPa). The slab is composed of 20MPa compressive strength concrete casted on a steel deck with ribs perpendicular to the steel profile. Two series of models were tested, each one with two models, totalizing four tests. The models named F1 and F2 refer to beams with friction at the interface between slab and steel profile

Gilson Queiroz et al. and the models NF1 and NF2 had no friction contribution. Figure 3 shows the difference between the two series: the placement of teflon plates at the bolt M12 slab-steel profile interface in order to remove the friction force. bolt M12 Figure 3 Details of the slab-steel profile interface. (a) models F1 and F2 with friction. (b) models NF1 and NF2 without friction. steel deck support (a) steel deck support teflon plates (b) The shear connectors (Figs. 2) were made of 12mm diameter high-strength bolts (DIN 960 class 5.8 steel) and SAE 1040 rivets. Push-out tests performed in a similar composite beam with these shear connectors and steel deck ribs parallel to the steel profile yielded the average load slip curve illustrated in Figure 4, from which one can calculate the initial stiffness associated to one connector equal to 70 kn/cm. 60 It is indeed a very flexible connector leading to partial interaction behavior of the composite beam. The low stiffness is due to bearing deformation of the 2mm thick plate (and consequent hole ovalization). 50 load (kn) 40 30 20 10 Figure 4 Load slip curves of the shear connection associated to one connector (BREMER, 2007). The curve fitted to the experimental points was adjusted to be used in the numerical model (see Section 3). 0 0 5 10 15 20 slip (mm) adjusted curve - numerical model fitted curve experimental The beam was designed for full connection (governed by steel strength) resulting in 22 connectors almost uniformly distributed along each side of the midspan section. The beam models were subjected to four concentrated forces in order to simulate a uniform loading. Figure 5 shows the test setup and the model instrumentation, which consists of displacement transducers (DT) at midspan and also at the beam ends to measure end slips, as well as several strain gages (EER) along the beam height at midspan section. C EER concrete DT north DT sou EER up 1 EER up 2 EER low DT Figure 5 Setup for experimental tests and model instrumentation (units:mm). 750 600 800 600 750 test slab REM: R. Esc. Minas, Ouro Preto, 67(3), 253-258, jul. sep. 2014 255

Estimation of friction contribution in the behavior of steel-concrete composite beams with flexible shear connectors 2.2 Experimental results Figure 6 presents the beam responses in terms of bending moment x deflection at midspan section for all four tested models. It was possible to observe the favorable influence of friction to the beam stiffness and resistance. Collapse loads and bending moments can be found in Table 1, where bending moment (knm) 120 100 80 60 40 20 L/300 it is shown that the ratio between the average collapse bending moments of the beams with friction and without friction achieved 1.16. This result was obtained for profiles with a painted surface, which means that higher values are expected for the untreated surface. Once the service F 2 F 1 NF 1 NF2 bending moment is defined as the one associated with the limit deflection equal to L/300, it can be noticed in Figure 6 that this moment corresponds to 46 kn.m for the beam with friction and to 40 kn.m to beam without friction, a difference of 11% assigned to the favorable effect of friction. 0 0 10 20 30 40 50 60 70 midspan vertical displacement (mm) Figure 6 Bending moment deflection curves for the four models tested (Oliveira, 2009). Model Collapse load (kn) Collapse bending moment M c (knm) Average M c (knm) M c with friction M c without friction F1 174.2 94.3 F2 176.2 95.4 NF1 148.4 80.8 94.8 81.5 NF2 151.1 82.2 Table 1 Collapse load and bending moment Mc 3. Numerical model 1.16 A finite element model was developed allowing elastic and plastic analyses of simple or continuous composite beams, including friction at the interface, with any type of loading applied to the slab or to the I section profile. The software ANSYS version 11.0 and the following elements were used (see Figures 7): 1. Solid 65 used to model the concrete slab; material modeling for compression consists of multilinear stress-strain curve and the Von Mises yield criterion (avoiding any stiffness degradation due to concrete crushing); William & Warnke failure model allowing for cracking in the tension zone was adopted. 2. Shell 181 used to model the 256 REM: R. Esc. Minas, Ouro Preto, 67(3), 253-258, jul. sep. 2014 steel profile, with Von Mises criteria, multilinear stress-strain relation and kinematic hardening; 3. Link 8 auxiliary elements used to model the shear connector spring at the slab center level ; 4. Link 10 tension resistant only, used to avoid vertical separation between slab and steel profile; 5. Contac 12 used to model the friction at the interface between slab and steel profile; 6. Combin 39 nonlinear spring element used to model the load-slip curve of the shear connectors. The 87.5cm width concrete slab was modeled with 4 layers of solid elements across its 6.5 cm thickness. The transversal reinforcing bars were considered as smeared throughout the solid finite elements of the two upper layers while the longitudinal ones were modeled within the elements in the region of their locations. Multilinear kinematic hardening model and Von Mises yield criterion are used for the rebars. In the solution of the system of equations, incremental load steps varied in the range between 0.01 and 0.015% of the ultimate load. In a previous study, a less refined numerical model was developed to simulate the experimental tests in which shell elements were used to discretize the slab (QUEIROZ et al., 2010). Concrete stiffness degradation after cracking in the tension zone was not considered in this model.

Gilson Queiroz et al. ELEMENTS MAT NUM NV (a) combin39 slab C L contac 12 Figure 7 Finite Element model using solid elements to simulate the slab. (a) general view; (b) detailed view; (c) elements at the concrete-steel interface. link 8 link 10 link 8 profile top (c) (b) 4. Comparisons between numerical and experimental results The models of series F and NF tested at the laboratory were simulated with the finite element models described in section 3. For that purpose the CFP box section was transformed to an equivalent I shape. Figure 4 shows the connectors load slip curve (in dotted line) adopted in the numerical model. The curve fitted to the experimental results was further adjusted to consider the lower number of shear connectors of the numerical model in each beam side (17 connectors) as compared to the physical model (22 connectors). Figure 8 shows the comparison between the experimental results from the tests with and without friction and their numerical counterparts obtained with two models: the one described in section 3 in which solid elements were used to simulate the slab ( slab solid65) and the model presented in a previous study where shell elements represented the slab ( slab shell ). Figure 8 Comparison between numerical and experimental results. In both simulations, with and without friction, the slab solid65 model displayed convergence problems and the analyses were precociously interrupted. Nevertheless, it can be noticed in Fig 8a that the result obtained with this model displayed a very good correlation with the NF1 test, without friction. For the case with friction (Fig. 8b), the behavior of the beam was well simulated by this model until half collapse load approximately; after 5. Conclusions that load the numerical model presented greater flexibility than the experimental one. This can be explained by problems of friction simulation in the numerical model which, in this case, led to a significant difference in the results. For the test without friction (Fig. 8a), the numerical model slab shell displayed a more rigid behavior than the model slab solid65 and the physical model due to a poor simulation of the slab material, which does not take into account stiffness degradation after concrete cracking. On the other hand the simulation of the beam with friction (Fig.8b) seems to show a very good correlation with the experimental results but in this case two opposite effects contribute to this performance: the absence of the steel profile sheeting in the numerical model and the lack of appropriate modelling of the concrete in tension regions. The results of experimental tests in simple composite beams showed that friction at the interface between the slab and the steel profile plays an important role in the behaviour of short span beams with flexible connectors. For the REM: R. Esc. Minas, Ouro Preto, 67(3), 253-258, jul. sep. 2014 257

Estimation of friction contribution in the behavior of steel-concrete composite beams with flexible shear connectors 3.5m span tested beams with connectors composed by bolts threaded to rivets, a 16% increase in collapse bending moment was assigned to the friction favorable effect. It became evident that not only the connector strength but also the connector stiffness should be considered in the design, specifically in deflection evaluation. 6. Acknowledgments The authors gratefully acknowledge the financial support received from 7. References The two numerical models developed to simulate the behavior of the tested beams exhibited very good correlations with the experimental results until approximately half collapse load. After that point, issues like concrete modelling in the tension zone and the absence of the profile sheeting in the numerical models contribute to a FAPEMIG (Fundação de Amparo à Pesquisa do Estado de Minas Gerais). lower performance of their simulations. The more refined model using ANSYS element solid 65 displayed convergence problems which are currently being examined. Once validated, this numerical model may be used to simulate other practical situations for instance when part of the slab vertical reaction is supported by a transverse beam. Received: 20 March 2013 - Accepted: 25 July 2014. ABNT - Associação Brasileira de Normas Técnicas, Projeto e execução de estruturas de aço e de estruturas mistas aço e concreto de edifícios. NBR 8800, São Paulo, Brasil, 2008. AISC - American Institute of Steel Construction, Load and Resistance Factor Design Specification for Structural Steel Buildings, Chicago, 2005. ANSYS Version 11.0. Documentation. ANSYS, Inc. BREMER C.F. Vigas mistas em perfis formados a frio com lajes mistas e lajes moldadas sobre painéis de concreto celular, Belo Horizonte: Universidade Federal de Ouro Preto, 2007. (D. Sc. Thesis). OLIVEIRA, C.G.R. Análise teórico-experimental de vigas mistas com perfil formado a frio, flexibilidade dos conectores de cisalhamento e a influência do atrito entre o concreto e o aço do perfil, Belo Horizonte: Universidade Federal de Minas Gerais, 2009. (M.Sc Thesis) QUEIROZ, G, RODRIGUES, F, PEREIRA, S; PFEIL; M; OLIVEIRA; C; MATA; L. Behavior of steel-concrete composite beams with flexible shear connectors, In: Proc. Stability and Ductility of Steel Structures (SSDS Rio 2010), vol.1, p.863-870, Rio de Janeiro, 2010. QUEIROZ, G., PEREIRA, S.S.R; MATA, L.A.C., SILVA, M., Influence of friction at the slab/steel profile interface and of the flexibility of shear connectors in steel concrete composite beams, In: EUROMECH SOLID MECHANICS CONFE- RENCE, 7 th.lisbon, 2009. SILVA M.C. Análise numérica de vigas mistas levando em conta a flexibilidade e a ductilidade dos conectores de cisalhamento bem com o atrito na interface entre o aço e o concreto, Belo Horizonte: Universidade Federal de Minas Gerais, 2009. (M.Sc. Thesis) 258 REM: R. Esc. Minas, Ouro Preto, 67(3), 253-258, jul. sep. 2014