Reference: testing the Paragon Mobility Tsunami manual wheelchair to 114 kg user weight, our Laboratory reference is

Similar documents
DRAFT UGANDA STANDARD

MALTE Outdoor. the compact and versatile posterior-walker. Instructions for use

BESTMOVE STANDING TRANSFER AID

BESTMOVE STANDING TRANSFER AID

AADL # W324 ORDER FORM

The Edge Protection Federation Containment Systems Product Specification, Test Methods

AADL ORDER FORM Effective: February

DILLARD S TEST PROTOCOL FOR DILR US OUTDOOR GAS TABLETOP GRILL (V7)

Owner s Manual & Safety Instructions

Technical Specification for Steel Forged Fittings

NPS/001/024 Technical Specification for Low Voltage Aerial Bundled Conductor Fittings

FIBC Safe Handling Guidelines

Model # 600H-D. 4/2/2012 Page 1 of 6

Model # 612H. 7/11/2016 Page 1 of 6

Mechanical Testing. Tensile Compression Bend Flexure Proof Load Structures Fasteners Composites Concrete Fatigue Scaffolds Formwork Force Calibrations

BESTMOVE STANDING TRANSFER AID

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

HST -B Interlocking device (Translation of Original Manual)

SUPPLIER QUALITY CODES

Instruction Guide. FreeSpan SR. English

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

SECTION Permanent Grandstands PART 1 GENERAL 1.1 RELATED DOCUMENTS

Installation Manual. Orion. TL-3 Steel Barrier. VHD (v2)

DRYWALL DOLLY 900 LB. CAPACITY

Model # 362S-RDP. 9/17/2012 Page 1 of 12

KEEP FOR FUTURE REFERENCE FORKLIFT ADAPTER FOR MRTA6 AND MRTA8 LIFTERS READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT

Model #967- S6. 7/7/2016 Page 1 of 14

DAKE COMPOUND LEVERAGE ARBOR PRESS. Model 3 INSTRUCTIONAL MANUAL

City of Minot Auditorium Non-Upholstered Arena Seating Specifications

DILLARD S TEST PROTOCOL FOR DILR US PAPER TOWEL / TOILET PAPER HOLDER (V5)

SPECIFICATION OF NEOPRENE RUBBER SEALS

Dandy Leveler UDLV-150 & UDLV-500 (New Style)

The Kodiak 3200 Seating System by Royal Stewart Ltd.:

Alto CareChair Commode Chair ISO classification Stainless steel, aluminium, composite plastic Date of manufacture 12.02

HOME PRODUCT CERTIFICATION

DILLARD S TEST PROTOCOL FOR DILR US PICTURE FRAME (V6)

ENGLISH Compact Half Coupler 50 mm, SWL: 50 kg

COMBISAFE Multibox 9541 Multibox End Panel USER INSTRUCTIONS _001

Series 5550/5551 and Series 5630/5631 Acoustic Glass Walling

KEEP FOR FUTURE REFERENCE MRT FORKLIFT ADAPTER READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT

Model # 940S-P6-BB. 6/7/2017 Page 1 of 10

PE21 AMBER DOUBLE SWING OWNER S MANUAL

TABLE OF CONTENTS INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3

PE57 HOLT 2 DOUBLE SWING OWNER S MANUAL

Applied Engineering Analysis Pty. Ltd. A.C.N P.O. Box 828 Bayswater BC, Vic., 3153 Ph: (03) Fax: (03)

General Guidelines. Tools Required. Safety. Deluxe Steel Folding Scooter & Wheelchair Carrier Instructions for Part # SC500-V3

TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION

CHAIN SLINGS STANDARDS UPDATE

STATE OF NORTH CAROLINA C DEPARTMENT OF ADMINISTRATION February 1, 2013 PURCHASE AND CONTRACT DIVISION B February 23, 2005

MECHANICAL LEVELERS. P.O. Box 338 Spring Hill, Tennessee /486/ /251/3382 Fax 931/486/0316

CONTRACT SPECIFICATIONS DISK BEARINGS

Model # 338S-PR. 5/1/2014 Page 1 of 12

Model # 338S-P. 7/31/2012 Page 1 of 13

Quick Adjustable Height Stands

Defines quality requirements and expectations for Vanguard Suppliers.

Specification for the Fabrication of Tower Structures

Downloaded from

Model # 338S-RDP. 7/31/2012 Page 1 of 13

Mechanical Testing. Tensile Compression Bend Flexure Proof Load Structures Fasteners Composites Concrete Fatigue Scaffolds Formwork Force Calibrations

COUCHES. Task Fixed Height Table. Heavy Duty Exam Couch. Mobile Examination Couch. Overall dimensions: H 82cm x W 70cm x L 195cm

Model #369S-PR. 8/23/2016 Page 1 of 11

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE

Dear Customer. Section Old F4 January 2017 Amendment 2. Remove title page and document history page 1-2B

LOAD RAMP 1000 LB. CAPACITY

the fixed post kit product manual for folding clotheslines

Model #369S-RDP. 8/23/2016 Page 1 of 11

TABLE OF CONTENTS. FOREWORD... Error! Bookmark not defined. INTRODUCTION SCOPE NORMATIVE REFERENCES DRAWING...4

PalletPal Low Profile Disc Turntable

N1 to N3. DuraGalPlus Domestic Construction Manual. Volume 3: DuraGalPlus RHS as floor beams (bearers)

SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following:

SECTION MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

06/17 TABLES & DESKS INSTRUCTIONS FOR USE. Codes 2251, 2252, , 6967, 6968, , , 2445

Niklas portable freestand

General Guidelines. Tools Required. Steel Folding Scooter & Wheelchair Carrier Instructions for Part # SC400-V2. Safety

FITNESS PLAYGROUND ITEM NO: 8010

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

1. Supply, delivery, engineering and installation of new storage equipment.

Shackles. Applications. Range. Design. CAD drawings. Finish

2017/ Rev-AA.0

PV-ezRack SolarRoof Longline Interface

Radiant Solar Tripod Planning and Installation Guide V1.2 With Australia AS/NZS1170.2

EDILEGNOARREDO/FEDERLEGNOARREDO GUIDELINES ON STEEL DOORS, ONE LEAF, BURGLARY RESISTANCE TEST

Weld plate welding guidelines

CUAP 06.02/13. Blind rivets for metal members and sheeting

Regarding the refusal to issue a code compliance certificate for a house with a glass balustrade at 102 Oceanbeach Road, Tauranga

CLASSIFICATION NOTES. Type Approval. Mechanical Joints. used in Piping

Weld plate welding guidelines

TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION TANK, POLYETHYLENE, HORIZONTAL LEG, MINIMUM 500 GALLON CAPACITY PUBLICATION

Model # 357-MC. 8/13/2018 Page 1 of 12

Draft for comments only Not to be cited as East African Standard

DS-520 Digital Indicator Operation Manual 73366

Clenergy ezrack SolarRoof Code-Compliant Planning and Installation With Australia AS/NZS1170

Model # 338SM-OP. 9/30/2011 Page 1 of 12

LICENCE. for WEB LINKS. Check if this document is current Find similar documents StandardsWatch (info and login) Visit our website

FLARING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

SECTION ORNAMENTAL ALUMINUM FENCING

B. Related Sections include the following:

TEXAS DEPARTMENT OF TRANSPORTATION PROCUREMENT DIVISION TANK, POLYETHYLENE, ELLIPTICAL LEG, MINIMUM 1235 GALLON CAPACITY

OPERATION MANUAL BISON LIFTER (ABL150)

TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION

Transcription:

David Fagan, Mobility Manager Paragon Mobility Pty. Ltd. 3/10 Tapnor Crescent, Brendale, Queensland. 4500 24 th February, 2012 Dear David, Reference: testing the Paragon Mobility Tsunami manual wheelchair to 114 kg user weight, our Laboratory reference is 491629. This letter is to advise you that this Laboratory has finished testing your product to the following Standard method: AS3696-1:2008, AS3696-3:2008, AS3696-5:1989, AS3696-8:1998, ISO7176-7:1996 and the requirements of :1992 (except ignitibility, materials & surface finishes). The official twelve (12) page report, dated 24 th February 2012 and referencing job number 491629, identifies the sample, the test documents and the testing facility. All conformances with the Australian standards are indicated in the report. The Paragon Mobility Tsunami manual wheelchair as represented by the test sample, including the supplied documentation and labelling as stated in the test report, complies with the relevant requirements of the Australian Standard AS 3695 (excluding the methods indicated in the report as not tested or not applicable ) for user mass 114 kg. Please do not hesitate to contact us if you have any enquiries or comments regarding the test. Kind regards, Wayne Wurfel Senior Test Technician, Test Laboratory NATA signatory vitatech (a division of vita Children s Services 171 Days Road, Regency Park, South Australia 5010 PO Box 2438, Regency Park, South Australia 5942 Telephone 1300 855 585 Fax (08) 8243 8208 enquiries@novita.org.au www.novitatech.org.au ABN 53 137 537 636

TEST REPORT FOR Paragon Mobility Tsunami Manual Wheelchair (114 kg) TEST DOCUMENTS :1992, AS3696-1:2008, AS3696-3:2008, AS3696-5:1989, AS3696-8:1998, ISO7176-7:1996 LABORATORY REFERENCE 491629 24 th February 2012 Page 1 of 12

TEST REPORT This report may NOT be reproduced in part without written laboratory authorisation. The vitatech Test Laboratory has no control over the selection of test samples. Any extension of the findings of this report to cover production items must be based on the production being truly represented by the sample(s). PRODUCT Job no: 491629 Name and Model Paragon Mobility Tsunami MWC Serial no(s) of test sample TS001307 Maximum user mass 114 kg (250 lb) Documents used in testing :1992, AS3696-1:2008, AS3696-3:2008, AS3696-5:1989, AS3696-8:1998, ISO7176-7:1996 SUPPLIER Name Paragon Mobility Pty Ltd Address 3/10 Tapnor Crescent, Brendale, Queensland 4500 Telephone: 1300652382 Fax: (07) 3112 6125 Contact person: David Fagan, Mobility Manager Order.: n/a Order Date: n/a TESTING AUTHORITY NOVITA CHILDREN S SERVICES - NOVITATECH TEST LABORATORY 171 Days Road., Regency Park, South Australia, 5010 Telephone: (08) 8243 8289 Fax: (08) 8243 8208 Testing supervisor: Wayne Wurfel Checked: Richie Petronio Senior Test Technician (NATA signatory) Dates of testing period: January, February 2012 Date of issue of this report: 24 th February 2012 Page 2 of 12

Chair type: Manual, self- propelled, rear wheel drive Frame: Size Frame Tilt Recline Anti-tips Push handles Footrests Armrests Headrest Adult Rigid Individual push handles + bar Single 1 piece, height adjustable ne Seating: Backrest Width Height Description 420 mm 360 mm Sling type, padded fabric Seat Width Depth Description 420 mm 430 mm Sling type, fabric Wheels: Castor Front Rear Width 22 mm n/a Diameter 125 mm n/a Description Solid tyres n/a Drive Wheel Width Diameter Description 25 mm 600 mm Pneumatic Electrical: Charger Controller Other features n/a n/a n/a te: Other descriptive dimensions etc. may be included in part 5 and 7 of the test report Page 3 of 12

:1992, AS3696.1:2008 DETERMINATION OF STATIC STABILITY, MARKING AND LABELLING Test Stability facing down slope, brakes unlocked Stability facing down slope, downhill wheels locked Stability facing up slope, brakes unlocked Stability facing up slope, downhill wheels locked Stability facing up slope, with rear anti-tip devices Stability across slope, brakes locked Stability limits before Stability Specification action (if any) to prevent limits according to sliding, description of Max./Min. AS3696.1 action Max./Min >15 ne >10 6.1 9 >15 ne >10 6.1 9 14.3 ne >10 6.1 10 13.6 ne >10 6.1 10 >11 ne >10 6.1 11 >12 ne >10 6.1 12 Performance Requirements (, Clauses 6.1, 8.1 (f), 8.1 (h)) The chair was tested with a carry bag loaded to the maximum stated weight if supplied with the chair, or hooks or the like are provided The wheelchair shall be permanently marked The wheelchair is permanently marked CAUTION Limited stability wheelchair Tips on a slope of less than 10 ne. WW. End of remarks --------------------------- The sample submitted for this test satisfies the relevant requirements of AS3696.1-2008 and -1992 (except the methods indicated in this report as not tested and/or tested with deviations) for user mass 114kg. Yes Page 4 of 12

:1992, AS3696.3:2008 DETERMINATION OF BRAKE EFFICIENCY, PARKING BRAKE TEST Test Measured critical value Type of failure: brake failure, skidding or tipping Specification according to AS3696.3 Force to apply brakes 55 N 6 Parking brakes facing down slope 11.7 Loss of traction at 10.8 >10 6.3.1 7.2 Parking brakes facing up slope 18.4 Brake creep at 18.5 >10 6.3.1 7.2 Specification Test. cycles according to AS3696.3 AS3696.3 Brakes fatigue 60,000 cycles 60,000 cycles 6.3.1 8 Measured Test critical value Parking brakes facing down slope 11.7 Parking brakes facing up slope 18.2 Type of failure: brake failure, skidding or tipping Loss of traction at 11.8 Brake creep at 18.3 Specification according to AS3696.3 >10 6.3.1 8, 7.2 >10 6.3.1 8, 7.2 ne. WW. End of remarks ------------------------- The sample submitted for this test satisfies the relevant requirements of AS3696.3-2008 and -1992 (except the methods indicated in this report as not tested and/or tested with deviations) for user mass 114kg. Yes Page 5 of 12

:1992, AS3696.5:1989 OVERALL DIMENSIONS, MASS AND TURNING SPACE Overall dimensions (Clause 5 of AS3696.3) Dimensions, to the nearest Measured Dimensions, to the nearest Measured 10mm value 10mm value AS3696.5 AS3696.5 Dimensions ready for occupation 5.1 Folded dimensions 5.2 Length, mm 900 5.1.1 Min. folded length, mm 735 5.2.1 Length (no footrest or support), mm 900 5.1.2 Min. folded width, mm 575 5.2.2 Width, mm 610 5.1.3 Min. folded height, mm 600 5.2.3 Overall height, mm 840 5.1.4 Min folded volume, cu.m. 0.253 5.2.4 Mass, to the nearest Dimensions, to the nearest Measured Measured value kg 10mm value AS3696.5 AS3696.5 Mass 11.0 kg 6 Turning space 7 Min. turning radius, mm 605 7.1 Min. turn between walls, mm 1045 7.2 ne. WW. End of remarks ---------------------------- :1992, ISO 7176.7:1996 SEATING AND WHEEL DIMENSIONS, CLAUSE 4.6 - DIMENSIONS Dimensions (Clause 4.6 of ISO DIS 7176.7) Dimension Reference Reference Measured Measured dimension in dimension in values Dimension values ISO DIS ISO DIS Min/Max Min/Max 7176.7 7176.7 Seat plane angle, 7.9 1 Effective seat depth, mm 435 2 Max. seat width, mm 420 3 Seat surface height, front edge, mm 445 5 Backrest angle, 5.7 6 Backrest height, mm 390 7 The size of RLG: Adult ne. WW. End of remarks ----------------------------- Page 6 of 12

List of failures (, Clause 6.4) :1992, AS3696.8:1998 STATIC, IMPACT AND FATIGUE TESTS Mode a b d f g h Failure description Components of the wheelchair are fractured or have visible cracks (except cracks in surface finishes) Any nut, bolt, screw, locking pin, adjustable component or similar item become detached after having been tightened, adjusted or refitted once. (Footrests may be adjusted after each of the two footrest impact tests) Parts intended to be removable, folding or adjustable do not operate as described by the manufacturer Handgrips are displaced Any multiposition or adjustable component is displaced from the present position (except as permitted in (b)) Deformation, free play or loss of adjustment of any component or assembly, that adversely affects the function of the wheelchair Test method for static strength Armrest resistance to downward forces (NO DUMMY) Footrest resistance to downward forces (NO DUMMY) Tipping levers downwards load (DUMMY FITTED) Actual force, N n/a (no armrests) Specification according to a table of Table AS3696.8 Force, for 100kg user mass, N 2 760 Force, for 114kg user mass, (N) 868 N (Single) Mode of failure (see list of failures above) Reference in AS3696.8 n/a 8.4 1155 N 3 1000 1140 N ne 8.5 n/a 4 1000 1000 N n/a 8.6 Handgrips (DUMMY FITTED) 750 N 5 750 750 N ne 8.7 Armrests resistance to upward forces (DUMMY FITTED) Footrest resistance to upward forces (DUMMY FITTED) Push handle resistance to upward load (DUMMY FITTED) n/a (no armrests) 1000 N 7 440 each 1000 N (each) 6 895 1000 N n/a 8.8 992 N (1 piece) ne 8.9 8 880 each 985 N ne 8.10 ne. WW. End of remarks ------------------------- Page 7 of 12

Test method for impact strength Mode of failure (see list of failures above) AS3696.8 Backrest resistance to impact (DUMMY THIGHS ONLY FITTED) ne 9.3 Handrim resistance to impact (DUMMY FITTED) ne 9.4 Castors (DUMMY FITTED) ne 9.5 Footrests resistance to lateral impact (DUMMY FITTED) ne 9.6.3 Footrests resistance to longitudinal impact (DUMMY FITTED) ne 9.6.4 Front structure resistance to frontal impact (DUMMY FITTED) n/a 9.7.2 Front structure resistance to offset impact (DUMMY FITTED) n/a 9.7.3 ne. WW. End of remarks -------------------------- Test method for fatigue strength Actual number of cycles Specification according to a table of AS3696.8, number of cycles Mode of failure (see list of failures above) AS3696.8 Two drum test 200,000 cycles 200,000 ne 10.4 Drop test 6,666 cycles 6,666 ne 10.5 ne. WW. End of remarks ----------- The sample submitted for this test satisfies the relevant requirements of AS3696.8-1998 and -1992 (except the methods indicated in this report as not tested and/or tested with deviations) for user mass 114kg. Yes Page 8 of 12

:1992, Clause 5 DESIGN AND CONSTRUCTION REQUIREMENTS The sample satisfies Design and Construction requirements for protuberances (, Clause 5.1) Burrs or sharp edges on accessible parts of the wheelchair The sample satisfies Design and construction requirements for footrests (, Clause 5.6) For swinging and removable footrests the locking mechanism is positive, easily moved and operated Movement greater than 10mm when the footrest is loaded and when a horizontal load of 100N is applied in any direction ne. WW. End of remarks ---------- The sample submitted for this test satisfies the relevant requirements of -1992 (except the methods indicated in this report as not tested and/or tested with deviations) Yes :1992, Clause 4 MATERIALS The sample satisfies Materials requirements (, Clause 4.1, 4.2 and 4.3) All metal parts are made of corrosion-resistant material or are protected against corrosion Stainless steel the surface finish of uncoated stainless steel comply with the requirements for finish. 4 of AS 1449 Electroplated coatings of nickel and chromium nickel and chromium electroplating comply with the requirements for Service Condition. 3 (Severe) of AS 1192 Anodised finish anodised aluminium frames are anodised in accordance with the requirements for Grade 4 (minimum average thickness 10 m) of AS 1956 Upholstered components of the wheelchair show neither progressive smouldering nor flaming when tested in accordance with AS 3744.2 t tested t tested t tested t tested t tested Corrosion resistance, surface finishes, coatings and flammability were not assessed. WW. End of remarks ------------------------------------ The sample submitted for this test satisfies the relevant requirements of -1992 (ignitability only) t assessed Page 9 of 12

:1992, Clauses 8 and 9 MARKING AND INFORMATIVE LABELING Requirements Result of verification The following information is plainly marked in a permanent manner on the sample: 8.1 The registered trade name or trademark of the manufacturer 8.1 (a) The name and address of the Australian distributor or a space allocated for the name and address of the Australian distributor are marked on the wheelchair (See remarks) 8.1 (b) The model designation and serial number of the wheelchair 8.1 (c) Any appropriate cautions and warnings 8.1 (d) Recommended maximum weight of the user If a carry bag is supplied with the wheelchair, or hooks or the like are provided for a carry bag, a statement giving the maximum load to be carried (See remarks) NA 8.1 (e) 8.1 (h) Tyres if pneumatic are marked with the size and recommended inflation pressure in kpa 8.2 The following information is available to the purchaser, and is printed in English: 9.1 Specification information for the wheelchair including The model designation or any other information that will uniquely identify the wheelchair 9.1 (a) (i) The mass of the test dummy or human equivalent (if used) 9.1 (a) (ii) The information on the performance attributes of the test wheelchair, i.e. test results of static stability tests (AS 3696.1), determination of the efficiency of brakes tests (AS3696.3) and static, impact and fatigue tests (AS3696.8), dimensional attributes of the wheelchair (AS3696.5 and ISO7176.7). (See remarks) 9.1 (a) 9.1 (a) (iii) A statement as to which features and options are included in a specific wheelchair 9.1 (b) A description of the intended user, including but not limited to maximum recommended weight 9.1 (c) Details of the warranty or, where no warranty is provided, a clear statement to that effect 9.1 (d) Information on how to get repairs and service 9.1 (e) Information as to whether a service manual is available 9.1 (f) Additional information is available on request, i.e. in addition to the minimum information contained in the specification sheets, the manufacturer or importer makes available, on request, all information resulting from testing to this Standard 9.2 At least one copy of the user s manual is supplied with each wheelchair sold 9.3.1 When illustrations show components that are referred to in the text of the user s manual, these components are numbered or named for positive identification, illustrations are numbered or named for positive identification 9.3.2 Warranty statements are included as part of the user s manual 9.3.3 The following information concerning the general characteristics of the wheelchair is included in the user s manual: A physical description of the wheelchair accompanied by photographs or drawings of the wheelchair and a non-technical description of how the wheelchair is intended to be used 9.3.4 9.3.4 (a) A description of the intended user, including but not limited to maximum weight 9.3.4 (b) Page 10 of 12

:1992, Clauses 8 and 9 MARKING AND INFORMATIVE LABELING (CONT.) Requirements The environment in which the wheelchair is intended to be used and a description of any environmental conditions such as temperature and humidity that might be harmful to the wheelchair Result of verification 9.3.4 (c) A complete list of all accessories and tools that are supplied with the wheelchair 9.3.4 (d) If a wheelchair or accessory is marketed as user-installed or assembled, then the user s manual for that wheelchair includes the following information: 9.3.5 A list of components 9.3.5 (a) Information about any tools or equipment needed to assemble the wheelchair and its accessories 9.3.5 (b) Instructions for assembling, installing and removing any accessories supplied by the manufacturer 9.3.5 (c) Instructions on how to prepare the wheelchair for storage, shipment or travel 9.3.5 (d) The following information required for operating the wheelchair is included in the user s manual: 9.3.6 Complete operating instructions including instructions for operation of the wheelchair on surfaces likely to be encountered by the user, supplemented by appropriate illustrations, e.g. depicting the wheelchair on ramps, steep terrain, kerbs or steps Any common misuse of the wheelchair known by the manufacturer that might lead to personal injury or damage to the wheelchair The following information concerning maintenance of a wheelchair is included in the user s manual for that wheelchair Regular maintenance instructions accompanied by annotated illustrations including 9.3.6 (a) 9.3.6 (b) 9.3.7 9.3.7 (a) Any service, maintenance and fault finding that the manufacturer intends the user to do 9.3.7 (a) (i) Information about the types of tools or equipment needed to repair and service the wheelchair and its accessories 9.3.7 (a) (ii) Frequency of maintenance 9.3.7 (a) (iii) A list of materials necessary, including part numbers and procurement information 9.3.7 (a) (iv) Identification of circumstances in which the complete wheelchair should be returned to the manufacturer, distributor or service agent for maintenance 9.3.7 (a) (v) Instructions on methods of cleaning 9.3.7 (b) A list of parts that are intended by the manufacturer to be readily replaced, e.g. tyres, with special ordering information. Instructions for access, removal, replacement and testing of these parts are accompanied by annotated illustrations of the part and its location in the wheelchair 9.3.7 (c) A description of potentially hazardous maintenance operations such as tyre inflation 9.3.7 (d) Performance check instructions for carrying out any necessary performance checks intended by a manufacturer on a wheelchair are included in the user s manual 9.3.8 Proper procedures for having a wheelchair repaired are described in the user s manual and include at least the following: 9.3.9 Identification of parts that are intended to be repaired by the user 9.3.9 (a) Identification of parts to be serviced by the manufacturer or an authorized service facility in order to maintain the serviceability of the wheelchair 9.3.9 (b) Page 11 of 12

:1992, Clauses 8 and 9 MARKING AND INFORMATIVE LABELING (CONT.) Requirements Result of verification Identification of any parts that can be removed and sent to the manufacturer/distributor or other party for repair 9.3.9 (c) Identification of circumstances in which the complete wheelchair should be returned to the manufacturer, distributor or service agent for repair 9.3.9 (d) A list of authorized service facilities 9.3.9 (e) Information on whether replacement units are available 9.3.9 (f) Packing and shipping instructions 9.3.8 (g) Sample supplied for testing did not have a label attached covering the requirements of Clauses 8.1(b & e) Compliance is conditional that a label be permanently attached to all products made available for sale, meeting the requirements of these clauses. The user s manual for the wheelchair should be made available for perusal by the purchaser at the point of sale. Items 9.1 (a) (iii), 9.3.9 (e) may not be known to the manufacturer at the time that compliance with this Standard is sought. In such cases, the manufacturer may be required to demonstrate an agreement with any distributor for this information to be supplied to the purchaser. WW. End of remarks ----------- The sample submitted for this test satisfies the relevant requirements of -1992 (except the methods indicated in this report as not tested and/or tested with deviations) Yes NOTES 1U 95 Uncertainty of measurements where not specified: linear 1mm, angular +- 30', force, mass 1%, temperature 1 C, cycles 1 count. This means the true measurement is within the stated tolerances at least ninety five times in one hundred 2 All testing was carried out in a controlled environment laboratory using methods set out in the Standards documents, all deviations and additions to the Standards methods are noted in remarks. 3 All instruments either carried valid calibration certificates throughout the test period or were checked against traceable Standards before and after use. 4 The vitatech Test Laboratory has no control over the selection of test samples. Any extension of the findings of this report to cover production items must be based on production being truly represented by the sample(s). 5 Any non-conformances are indicated in red. END OF REPORT Page 12 of 12