Service Bulletin. ATA 51-20: Processes Leading Edge Protective Tape Installation

Similar documents
CIRRUS AIRPLANE MAINTENANCE MANUAL

ICE PROTECTION - AIRFOIL

Poly and Anti Graffiti Films Clear exterior films safeguarding plastic substrates from scratches, discoloration and graffiti.

Limited Time. Job-Ready. Value Priced.

Avery Dennison Instructional Bulletin 1.6 Printing, Processing and Application of Interior Wall Graphics

Read the following instructions prior to application. Europe

SlimLine Neo-Angle Base & Q-Wall-2

Avery Dennison Instructional Bulletin 1.6 Printing, Processing and Application of Interior Wall Graphics

SB E Mandatory September 19, 2008 Model 300, 350, & 400

TITLE: 3M Controltac Plus Series 250 with Comply Performance. Description Page 2. Intended Applications Page 2. Performance Life (Unprinted) Page 2

TRIDENT SEC 04 SECTION SAFETY AND SECURITY FILMS

TRIDENT SEC 06 SECTION SAFETY AND SECURITY FILMS

PALISADE PD 40 SECTION SOLAR CONTROL FILMS. A. Optically clear Titanium Nitride ceramic sputtered polyester film for solar control.

SERVICE BULLETIN. 525B (CJ3) -0263, thru -0316, thru -0337, -0339

CIRRUS AIRPLANE MAINTENANCE MANUAL

SERVICE BULLETIN SB

NOTE: Recommended upgrade for those operating in open sea conditions. 7. Approval: All information provided is in accordance with approved data.

Application Instructions for Avery Dennison Supreme Wrapping Film

SERVICE LETTER SERIAL NUMBERS

Printing, Processing and Application Instructions for Interior Wall Graphics

SkyLite S20X Installation and Maintenance of Hanita SkyLite S20X Films for Glass Substrates

Printing, Processing and Application Instructions for Wall Graphics Instructional Bulletin #6.50 (Revision 9) Dated: 02/13/18

Mandatory: Shall be accomplished within the next 100 hours of operation or 12 months, whichever occurs first.

TRIDENT S8 DN 35 SECTION SAFETY AND SECURITY FILMS

EFFECTIVITY: KODIAK 100 Series Aircraft Serial Numbers: thru with External Cargo Compartments.

SERVICE BULLETIN REVISION TRANSMITTAL

PILATUS AIRCRAFT LTD. CH-6371 STANS, SWITZERLAND SERVICE BULLETIN NO: REF NO: 021 MODIFICATION NO: ATA CHAPTER: 55

A. Submit product data sheets and literature verifying physical properties of materials.

Application Avery Dennison SuperCast films on irregular substrates Instructional Bulletin #4.07 (Revision 2) Dated: 01/16/17

A. Submit product data sheets and literature verifying fire ratings and physical properties of materials.

writelite & writeprolite (self adhesive film)

Note: Delete any section below not relevant to this project; add others as required.

Application of 3M DI-NOC Films A Guide for Indoor and Outdoor Dry Applications

Application. General Procedures for Interior and Exterior Dry Applications

Wabo FireShield Model: FSH

General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions.

NIGHTSCAPE NS05 SECTION SOLAR CONTROL FILMS

Installation Instructions

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

MirroFlex Tub and Shower Walls Kit Installation Instructions

SB-GA Issue 6

Single Engine Service Bulletin SEB85-7 Revision 3, Elevator And Trim Tab Inspection

Application of Avery MPI cast films on irregular substrates issued: 25/01/2011

Instructions for On-Site Coating of Vinyl Windows

TUFF-TAC TM BRIDGE MEMBRANE INSTALLATION GUIDE

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

CIRRUS I LLUSTRATED PARTS CATALOG

3M TM Decorative Radiant Film 76929SR

Application of Avery Dennison SW 900 Series Films Instructional Bulletin #4.08 (Revision 2) Dated: 01/17/17

Application and Maintenance

MILITARY SPECIFICATION CHEMICAL CONVERSION MATERIALS FOR COATING ALUMINUM AND ALUMINUM ALLOYS

MILITARY SPECIFICATION CHEMICAL CONVERSION MATERIALS FOR COATING ALUMINUM AND ALUMINUM ALLOYS

DOWSIL 123 Silicone Seal

3M Decorative Polyester Glass Film

DOOR SEAL KIT P/N , , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6

3 Aircraft Belly Protective Tape

Instruction Guide APPLICATION OF CIM TO ASPHALT

A. Section Mirrors; mirrors for architectural application to receive window film.

Instruction Guide APPLICATION OF CIM TO EARTHEN PONDS AND RESERVOIRS (USING CIM SCRIM)

A. Section Mirrors; mirrors for architectural application to receive window film.

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Intercure 99NA Application Guidelines

SECTION WINDOW FILM. A. Section Windows; windows to receive architectural window film.

Granite Vanity Top Installation Instructions

Installation Instructions

SERVICE LETTER. Also affected are all Kelly or HET alternators identified in HET Service Bulletin No. 053 in Authorized Service Facility stock.

ASTEC Re-Ply Roof System for AGED SINGLE PLY MEMBRANE (PVC, EPDM, THERMOPLASTIC) ROOFS

Mix ratio (by volume): CA8000/B900A (base component) CA8000B (activator component) Grade D BMS Type II Class B.

MANDATORY SERVICE BULLETIN NO. MSB /1 NO. MSB-F4-013

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Promotional Advertising

Indoor Carpet Advertising

Installation Instructions. Important. Recommended Tools. Palladium Rigid Sheet/Rubrail or Palladium G2 Sheet/Rubrail. Storage

Indoor Carpet Advertising System Primed White Opaque Base/Clear Velvet Overlaminate

Commander Owners Group

Installation Data PSL/R, PSML/R, PSTL/R, PSTML/R, PSL/R, PSML/R, PSTL/R, PSTML/R

SECTION PAVEMENT MARKINGS

Graphic Package Installation Instructions

ReflectiClean Acrylic/Urethane

ASTEC Re-Ply Roof System for ASPHALT & MODIFIED BITUMEN ROOFS

MOONEY AIRCRAFT, INC. M-18 SERVICE LETTER NO. 16 (This Service Letter is F. A. A. Approved)

SECTION DRY ERASE COATING (IdeaPaint CREATE Black and White) A. Section Gypsum Board Assemblies; gypsum board substrate.

VELCRO brand Adhesives. p re s s u re sensitive, fire re t a rd a n t, solve n t and heat ac t i v a t e d

ASTEC Re-Ply Roof System for ASPHALT & MODIFIED BITUMEN ROOFS

ERSYSTEM ONESTEP PLUS

SlimLine Single Threshold Base & Q-Wall-5.1 BASE & BACKWALL INSTALLATION INSTRUCTIONS

URETHANE. Asphalt Restoration Aged BUR and Modified Bitumen Sample Design Guideline

ITEM 458 WATERPROOFING FOR STRUCTURES

Marine Fire Wrap General Installation Instructions Cable Penetrations through A0-A60 and B0-B30 Bulkheads and Decks

PIAGGIO AERO INDUSTRIES S.p.A.

ENGINEERED LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING

MANDATORY SERVICE BULLETIN SB12-07 *MANDATORY SERVICE BULLETIN* KODIAK. REVISION: 00 DATE: September 26, 2012

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Application Procedures for Uncured Rubber Linings on Pipe

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

FluoroSyl 880. Surface Preparation

Acrylic/Urethane. Metal Roof Restoration Sample Design Guideline

BULLETIN PIPER CONSIDERS COMPLIANCE MANDATORY. Piper Aircraft, Inc Piper Drive Vero Beach, FL, U.S.A Date: February 2, 2018 (S) (M)

Adhesive Transfer Tapes with

Instruction Guide APPLICATION OF CIM TO CONCRETE

Transcription:

Service Bulletin Issued: Model SR22 ATA 51-20: Processes Leading Edge Protective Tape Installation COMPLIANCE Recommended: Accomplish this Service Bulletin at the next maintenance, annual inspection, or within the next 25 flight hours, whichever occurs first. Compliance time begins upon receipt of this Service Bulletin. Cirrus Design recommends compliance with this Service Bulletin as soon as possible to reduce potential for paint failure. EFFECTIVITY Cirrus Design SR22 serial numbers 2573 thru 2588, 2590, 2592, 2594, 2596 thru 2598, 2600 thru 2602, 2604 thru 2606, 2608 thru 2610, 2612 thru 2634, 2636 thru 2650, 2652, 2654, 2656 thru 2663, 2665, and 2666. APPROVAL FAA approval has been obtained on all technical data in this Service Bulletin that affects type design. PURPOSE On affected aircraft, the leading edge area paint may be subject to peeling, especially during flight into precipitation. This Service Bulletin provides for the installation of polyurethane protective tape (PPT) at the seam between the porous panel and painted surface of the wing and horizontal stabilizer. DESCRIPTION This Service Bulletin contains instructions for the installation of polyurethane protective tape (PPT) at the paint transition of the wing and horizontal stabilizer to the porous panel. Also, standalone instructions for PPT removal are provided to facilitate any future maintenance. WARRANTY INFORMATION Cirrus Design will cover parts and labor costs for this Service Bulletin if the work is accomplished at an authorized Cirrus Design Service Center. The Warranty Claim Form must be properly filled out and submitted to Cirrus Design in order to obtain a warranty credit. MANPOWER REQUIREMENTS Serials w/o paint damage: 2.0 manhours. Serials w/ paint damage: Contact Cirrus Design for disposition. OTHER PUBLICATIONS AFFECTED N/A Cirrus Design Corporation 4515 Taylor Circle Duluth, Minnesota 55811 PH (218) 727-2737 1 of 6 Cirrus Design Corporation cannot be responsible for the quality of work performed by others while fulfilling the requirements of this service bulletin. Procedures specified in this service bulletin must be accomplished using industry standard maintenance practices and applicable government regulations.

WEIGHT AND BALANCE N/A MATERIAL INFORMATION The following parts are required to comply with this Service Bulletin. Parts can be obtained from an Authorized Cirrus Design Service Center or Parts Distributor. Order kit 70199-001 to obtain the following parts. Item No. Description P/N or Spec. Supplier Quantity 1 Polyurethane Protective Tape (PPT) 51325-001 Cirrus Design 2 ACCOMPLISHMENT INSTRUCTIONS A. Inspect exterior finish. 1. At seam between porous panel and painted surface, inspect for signs of paint damage. a. If no paint damage exists, perform Procedure - Polyurethane Protective Tape Installation. b. If paint damage exists, contact Cirrus Design for disposition. B. Procedure - Polyurethane Protective Tape Installation (See Figure 01) 1. Acquire necessary tools, equipment, and supplies. Description P/N or Spec. Supplier Purpose Isopropyl Alcohol TT-I-735 Grade A or B Any Source Cleaning. Cotton Cloth (clean, lint free) - Any Source Cleaning. Scour Pad 7447 3M Company 888-364-3577 Adhesion Promoter 86A 3M Company 888-364-3577 Abrasion. Adhere. Masking Tape - Any Source Protection. Low Tack Tape - Any Source Protection. Rapid Tac Application Fluid RT-00321-2 or Non-Commercial Application Fluid 1 - Liquid Detergent 2 4 drops Isopropyl Alcohol 1/4 pint Water 3/4 pint Rapid Tac 800-350-7751 Any Source Facilitate PPT positioning. Plastic Squeegee - Any Source Smooth out PPT. Utility Knife - Any Source Cut PPT. Pin - Any Source Puncture PPT. 1. 4 drops liquid detergent to 1/4 pint isopropyl alcohol to 3/4 pint water. 2. Do not substitute liquid soap for liquid detergent. Soap is a fatty acid-based solution that will leave a residue when dry and interfere with PPT adhesion. 2 of 6

2. Prepare area at seam between porous panel and painted surface. a. Apply masking tape to painted surface 0.5 inch (1.27 cm) from porous panel. Repeat masking tape application along all upper and lower leading edges. b. Apply masking tape to porous panel 0.5 inch (1.27 cm) from painted surface. Repeat masking tape application along all upper and lower leading edges. c. At masked off areas, verify 0.5 inch (1.27 cm) of porous panel and 0.5 inch (1.27 cm) of painted surface is exposed. d. To prevent adhesive residue on masking tape from clogging holes on porous panel, apply low tack tape over all holes on porous panel. e. Use scour pad to abrade masked-off porous panel and painted surface. f. Solvent clean masked-off porous panel and painted surface. Dry area with clean, lint free cloth before solvent evaporates. Repeat solvent cleaning with clean cloth until free of debris. (Refer to AMM 20-30) g. Apply sufficient amount of adhesion promoter to fully wet the masked-off porous panel. CAUTION: Apply adhesion promoter only to masked-off porous panel and not painted surface. Areas where adhesion promoter is applied will accumulate dirt. Ensure adhesion promoter is not applied to areas that will not be covered with PPT. h. Allow adhesion promoter to dry for 10 minutes or until coated area is no longer glossy. 3. Apply Polyurethane Protective Tape. CAUTION: If paint damage was identified and repaired, paint must be fully cured for a minimum of 24 hours at 72 F (22 C) before applying PPT. Ensure air and application temperatures are above 60 F (16 C). Do not apply PPT over edge of masking tape. Apply PPT to porous panel within 2 hours following coat of adhesion promoter. Ensure porous panel and painted surface are clean prior to PPT application. Ensure hands are clean while working with PPT. a. Remove length of masking tape from porous panel to prevent PPT from overlapping masking tape. Retain length of masking tape on painted surface to facilitate alignment of PPT. b. Using application fluid, thoroughly spray masked-off porous panel and painted surface. c. Measure and cut PPT to length as required. To ensure sufficient length of PPT is obtained, cut PPT in excess of required length. d. Position PPT over seam between porous panel and painted surface. e. Gradually remove liner from PPT while thoroughly spraying adhesive side of PPT with application fluid, and applying PPT to seam. Lightly smooth out air bubbles at seam. Continue gradual removal of liner and application of PPT until entire seam is covered. f. To reduce friction between plastic squeegee and PPT, spray application fluid on film side of PPT. 3 of 6

g. Using squeegee with firm, overlapping strokes, smooth out PPT from the center out toward the edges in all directions. h. Dry entire area with cloth. i. Remove all remaining low tack and masking tape. j. Solvent clean entire area. Dry area with clean, lint free cloth before solvent evaporates. Repeat solvent cleaning with clean cloth until free of debris. (Refer to AMM 20-30) k. Work out air bubbles with the plastic squeegee. If air bubbles are present following application of PPT, puncture PPT at one end of the air bubble with a pin and press out with plastic squeegee toward puncture. l. Repeat at remaining seams on wing and horizontal stabilizer. 4. Allow applied PPT to adhere for 12 hours minimum and check for air bubbles. Re-squeegee and remove air bubbles if present. 5. Carefully trim inboard and outboard PPT as required. C. Complete airplane records by noting compliance with in Aircraft Logbook. 4 of 6

If future maintenance requires PPT removal, complete Procedure - Polyurethane Protective Tape Removal at required seams on wing and horizontal stabilizer. Procedure - Polyurethane Protective Tape Removal 1. Acquire necessary tools, equipment, and supplies. Description P/N or Spec. Supplier Purpose Isopropyl Alcohol TT-I-735 Grade A or B Any Source Cleaning. Cotton Cloth (clean, lint free) - Any Source Cleaning. Citrus-based Cleaner 76394 3M Company 888-364-3577 Cleaning. Masking Tape - Any Source Protection. Low Tack Tape - Any Source Protection. 2. Apply masking tape around perimeter of PPT. 3. To prevent adhesive residue on masking tape from clogging holes on porous panel, apply low tack tape over all holes on porous panel. 4. Apply citrus-based cleaner to PPT to soften adhesive. Allow citrus-based cleaner to permeate PPT. 5. Slowly peel end of PPT away from porous panel and painted surface while applying citrus-based cleaner to exposed adhesive-side of PPT. Continue breaking down adhesive while gradually peeling PPT until removed. 6. Apply citrus-based cleaner to porous panel and painted surface until adhesive residue is removed. 7. Dry entire area with cloth. 8. Remove all low tack and masking tape. 9. Solvent clean entire area. Dry area with clean, lint free cloth before solvent evaporates. Repeat solvent cleaning with clean cloth until free of debris. (Refer to AMM 20-30) 10. Perform required maintenance. Following all required maintenance, complete for any exposed seams. 5 of 6

MASKING TAPE (REF) PAINTED SURFACE (REF) 0.50 inch (1.27 cm) POLYURETHANE PROTECTIVE TAPE (REF) 0.50 inch (1.27 cm) POROUS PANEL (REF) NOTE Apply masking tape to painted surface 0.5 inch (1.27 cm) from porous panel. Apply masking tape to porous panel 0.5 inch (1.27 cm) from painted surface. To prevent adhesive residue on masking tape from clogging holes on porous panels, apply low tack tape over all holes on porous panels. Apply adhesion promoter only to masked-off porous panel and not painted surface. Prior to PPT installation, remove masking tape from porous panel to prevent PPT from overlapping masking tape. Retain length of masking tape on painted surface to facilitate alignment of PPT. Position PPT over seam between porous panel and painted surface. SR2_SB51_1251 Figure 01 - Leading Edge Protective Tape Installation 6 of 6

Service Loop Publications Change Request and Evaluation Form Use this form to submit a Publications Change Request to our Engineering Department and/or to tell us what you think of the quality of this publication. We will use the data you provide us to improve the quality of our technical publications. Contact Information: Organization: Today s Date: Address: Telephone No.: City/ST/Zip: Fax No: Prepared By: E-Mail: Title: Publication Type: Airplane Model: Publication Part Number: Title of Publication: Leading Edge Protective Tape Installation Publication Date (See Cover Page): Location of Publication Change Request: Chapter Number: Section Number: Figure No (IPC or WM only): Page Number: Page Date: Illustration Number (if applicable): Please consider the following suggestions for change: Evaluation: Please rate the quality of this publication. (good) 4 3 2 1 (poor) Please rate the quality of the illustrations. (good) 4 3 2 1 (poor) Is this publication easy to understand? (good) 4 3 2 1 (poor) Is this publication easy to use? (good) 4 3 2 1 (poor) Are the Material and Accomplishment Instructions accurate? (good) 4 3 2 1 (poor) Is the Manpower estimate accurate? (good) 4 3 2 1 (poor) Fax or mail this form to Cirrus Design Corporation: Manager - Technical Publications, 4515 Taylor Circle, Duluth, MN 55811 PH (218) 788-3000 FAX: (218) 529-7301 www.cirrusdesign.com

Cirrus Design Corp 4515 Taylor Circle Duluth, MN 55811-1548 STAMP CIRRUS DESIGN CORPORATION 4515 TAYLOR CIRCLE DULUTH, MN 55811-1548