GRP Flat Roofing Edge Trims

Similar documents
The Ultimate Flat Roofing systems. Product Guide. Topseal Product Guide

The Ultimate Flat Roofing systems. Product Guide. Topseal Product Guide

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings

BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING Two layer, EXCEL/SPOT fully adhered waterproofing system

LIQUID APPLIED WATERPROOF ROOF COATINGS

roofing ROOFING Design of the base ROOFING DETAILS

LIQUID APPLIED WATERPROOF ROOF COATINGS

INSTALLATION GUIDE.

URE IT. Installation Guide. Installation, handling, storage and technical information GRP WATERPROOFING SYSTEM

LIQUID APPLIED WATERPROOF ROOF COATINGS

INSTALLATION GUIDE. CromarGRP.com

J41 Reinforced bitumen membrane roof coverings

Cavity Tray Application

J41 Reinforced bitumen membrane roof coverings

ONDULINE MINI 18. The stylish Do it Once roofing upgrade for your garden buildings.

Specification. Project Name: Project reference: Written: by: Cathal Quinn Tel:

The better way to build TM. Installation Manual NAILBASE PANELS

Desmopol Application Guide onto Ply/OSB Deck

Training Manual. Installation guide, product datasheets, technical information, TREM cards and storage information

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

Eco Slate Installation Guide

LIQUID APPLIED WATERPROOF ROOF COATINGS

Outline NBS Specification. Protec System to Felt (Waterproofing Only)

NBS SECTION J41 - SCOPE OF WORKS

Garage Conversion - Between and Under Joist Applications

BENCHMARK Evolution Axis

DURABILITY PUNCTURE RESISTANCE LONG TERM PERFORMANCE

AS Interpretation of External Waterproofing as it applies to Melbourne, Class 1 buildings

Installation Guidelines INOFIN FR

GAF EnergyGuard Polyiso Wall Sheathing

Chapter 53: Endwall Overhang(s) Only - Enclosed

Insulation. Second Issue November Quick Guide. Building a better Kingdom together. Low Energy Low Carbon Buildings

Anticon roofing blanket

Sarnavap 5000E SA Vapour Control Layer

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

Roofing and Cladding. ALTERNA NT-slate APPLICATION INSTRUCTIONS 11

The complete fibreglass roof kit from the leader in GRP building materials

LIQUID APPLIED WATERPROOF ROOF COATINGS

PowerDeck F. PIR insulation for Warm Flat Roofs. Product Guide

Self Adhesive EPDM TRAINING MANUAL

New versatile and effective dry fix solutions for the roofline and above

5. Wall Trims & flashings

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

Thermal insulated roofing SYSTEM

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

Please Note: PhoneStar was previously branded as Phonewell

Wet Areas Using Plasterboard

NURAPLY 3PM ROOFING MEMBRANE INSTALLATION CHECKLISTS

GRP. The Performance Glass Reinforced Plastic System specifically designed for roofing PRODUCT SELECTOR & QUICK INSTALLATION GUIDE 25 YEAR GUARANTEE*

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].

The extra strong, extra durable, sound resistant system that you can direct fix to

Wall lining Inner leaf blockwork. K106 Cavity Board. Flexible sealant STANDARD DETAILS FOR 115 MM INSULATION BOARD IN A 125 MM CAVITY

SOPREMA JARDIN Double Layer Torch-on membrane For water proofing roof gardens and planters

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

STOPOREN FACADE SYSTEM APRON FLASHING

System Installation MANUAL

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

PROLOK EAVE PROLOK ROOFING PANEL ROOFING NAIL

application instructions

Tools & Equipment Chalk line Caulk gun 50-75mm brushes 2 hand roller Hammer Hook blade knife/scissors Pencils

Installation Instructions ALUTRIX 600 ALUTRIX FR

Flat roofs. Flat roof design. 2.3 Flat Roofs

100 mm. 100 mm. 125 mm. 125 mm. 150 mm. 150 mm C003 C001 C269 C208 C055 C002. Tee Gee. Feather Edge. Shiplap. Open V. Open V.

Contents P/ 3. Ensuring Optimal Results P/ 4. Roof Insulation SF40 P/ 5. Roof Insulation Over Rafter Application P/ 6

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

BARREL VAULT Tile Counter Batten and Batten Installation Guide

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

Viking Enviroclad Waterproofing Membrane. EC01 Enviroclad Drip Edge Specify from the above three options

STOPOREN FACADE SYSTEM PARAPET/METAL FLASHING DETAIL

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

Concrete Soffit Direct Fix

INSTALLATION INSTRUCTIONS KÖSTER TPO

ALLMET CONTINENTAL INSTALLATION GUIDE

The new high-performance lining for internal and external applications INSIDE OR OUT YOUR CHOICE

The professionals choice. Installation instructions Torridon. shower tray

11 FLAT ROOF CONSTRUCTION

INSTALLATION GUIDE.

NBS SECTION J42 - SCOPE OF WORKS

June Non - Residential Refurbishment Separating floors

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 protecting Membranes 90 System Components.

tra-load Damp Proof Courses Product and Systems Overview

Light-Metal Roof Edge, Raised

Pacific Tile Counter Batten and Batten

Pacific Tile Counter Batten and Batten

SRP-AirOutshield UV Issued:

August 2008: Issue 1. Non - Residential New Build 4.5 Basements

0331 Brick and block construction

EPA Seal and Insulate with ENERGY STAR Insulation Product Certification Report: GAF EnergyGuard Polyiso Insulated Sheathing Board Insulation

Classic and NB Tile Counter Batten and Batten

1 Firestone EPDM Roofing Systems

Architectural Roofing

SECTION BUILT-UP BITUMINOUS WATERPROOFING

OSB.COMFORT INSTALLATION GUIDE * 1 RECOMMENDED USE PANEL COMPOSITION

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions

Fibre cement slates. Cembrit Berona, Cembrit Berona Graphite, Cembrit Berona Xxtra, Cembrit Berona Stonedge, Cembrit Berona Structured

Transcription:

GRP Flat Roofing Edge Trims Compatible with GRP, rigid and flexible polyester, polyurethane, acrylic and alkyd systems. Trim Brochure and Technical Specification Guide

General Information The Easy To Use Edge Trim All of our GRP roof edge trims feature a unique high-adhesion finish that gives an excellent bond to most liquid applied and single-ply systems (tested with both rigid and flexible polyester, polyurethane, acrylic and alkyd systems.) Suitable for flat roofing, cladding, domestic and industrial applications. All Trims Feature: * Consistent weight and thickness * Excellent finish and appearance * High strength and flexibility * Easy jointing * Facilitates roof void ventilation * Unique high adhesion finish * U.V. stablisation * Pre-pigmented * Fire retardant to BS476 Part 3 * Weight: 550G/M 2 Notes GRP flat roof trims can be used to adapt most flat roofing systems to almost any application. Unless specified otherwise, our extruded profile trims are supplied in 3m lengths as standard. Where two lengths of edge trim need to be joined, a strip of polyurethane (PU) adhesive should be applied along the inside of the overlapping trim. When constructing a flat roof it is recommended to build a fall into the roof to aid drainage. Trim fascias may be painted at a later date using any suitable gloss or masonry paint. If used with a GRP roofing system, GRP edge trims can be laminated over their entire surface area if required or can be finished with topcoat applied directly to the surface of the trim. For further details on installing a GRP roof, please see our installation guide. Example of a Typical Cold Roof 3 2 6 7 8 9 5 1 4 1 B260 edge trim 2 D260 edge trim 3 C100 edge trim 4 A200 edge trim 5 C1 universal external corner 6 18mm OSB3 decking 7 450g/m 2 Chopped Strand Mat 8 GRP laminate (roofing resin reinforced by CSM) 9 Topcoat

Warm Roofs and Edge Trim Warm Roof A GRP roof can be easily configured in either a warm or cold roof specification. For a warm roof, a sub-deck is first fixed to the joists at 300mm centres. A vapour check and insulation sheet is then laid over the top. Insulation sheets can also be purchased with a vapour check adhered to one side. The decking should then be fixed on top as it normally would be, screws should be used to fix the boards to the joists and these should penetrate through the insulation and into the joists to the same depth as standard fixings. It is imperative that all layers of the roof are pressed firmly together and that there are no gaps between any of the layers. The GRP should then be laminated over the top of the roof as normal. These roofs will usually require larger edge trim sizes such as A250 and B300. To comply with the Part L Regulations of April 2006 the following specification would be required to obtain a 'U' value of 0.20 installed as shown below: 12mm Ply Sub Deck 100mm of Kingspan TR26 or equivalent 18mm T&G OSB3 board GRP laminate A170/A200/A250- Drip Trim The A type trim is a drip trim, fitted to the lowest edge of the roof usually where the rainwater flows into the gutter. Two support battens should be fixed to the perimeter of the roof to provide space for the gutter to fit behind the trim, with the outer batten attached 10mm lower than the inner batten to allow the trim to sit flush with the roof. Apply PU adhesive to the batten in 30mm beads at 300mm centres, rub the trim into place and nail to the decking. Do not nail through the front of the trim. If the pitch of the roof is only minimal, rainwater is likely to hold behind the trim. A planning machine can be used to take 2mm off the deck to allow the trim to lay flush with the board. TRIM DETAILS: A170: This is designed for applications where it is not possible to use the larger A200. A200: This is the standard size drip trim. A250: This drip trim is ideally suited for use on warm roofs. Cross-Section of Warm Roof onto Decking Cross-Section of A Trim 3 Warm Roof A170/A200 Decking and laminate Insulation with vapour check Subdeck Joist A250 or B300 trim would be applied to this edge. Decking and laminate. A250 trim would be applied in the same way over the top of the warm roof configuration shown opposite. A type trim.

Edge Trim B230/B260/B300- Raised Edge Trim A single batten is fixed level with the top edge of the deck. Apply 30mm beads of PU adhesive to the batten every 300mm, rub the trim into place and nail through the top of the trim into the decking. Do not nail through the front of the trim. If a ladder is likely to be leant against a B type trim for regular access to the roof, the trim will need to be reinforced to avoid deformation. The trim can either be doubled up by slotting a section of extra trim within the section where the ladder will be used or it can be reinforced with an extra layer of GRP laminate and then tissue to maintain a smooth finish. Alternatively, a wooden batten can be shaped and fitted into the ridge of the trim to ensure that it remains rigid. TRIM DETAILS: B230: The smallest size of raised edge trim fitted to the edges of the roof to contain and direct the flow of water. B260: The standard size raised edge trim. B300: Larger raised edge trim for use on warm roofs. Cross-Section of B Trim C100/C100MT/C100L/C100LMT/ C150/C150MT/C150L- Sim. Lead Flashing & D260/D300- Fillet Trim The C trim is a simulated lead flashing, generally fitted in conjunction with the D trim. The D trim is a fillet trim for use against abutting walls. It will also provide expansion and perimeter ventilation and is compatible with C2 and C3 universal corners. Place the D trim against the vertical face and push down diagonally into the corner until the trim fits snugly. Where the D trim needs to be joined it should be bonded with a strip of polyurethane adhesive and bandaged together. The C trim is usually fitted into a bed joint of the brickwork or a 35/50mm (depending on the trim type) deep chase cut out with an angle grinder fitted with a mortar chase disc. Apply polyurethane adhesive to the back of the C trim every 300mm. Fit the trim into the slot and press firmly back to the wall to overlap the D trim. Apply a clear silicone sealant along the length of the trim into the slot to seal the trim in. A smooth finish can be obtained by wiping the sealant with a moistened finger. TRIM DETAILS: C100: Standard simulated lead flashing with 100mm vertical face and 35mm wall penetration. Do not topcoat. C100MT: As C100 with self securing moisture trap. C100L (Long leg): As C100 with 50mm wall penetration. C100LMT (Long leg with Moisture Trap): As C100 with 50mm wall penetration and self securing moisture trap. C150: Simulated lead flashing with 150mm vertical face and 35mm wall penetration. Do not topcoat. C150MT (Moisture Trap): As C150 with an integral, self-securing moisture trap. C150L (Long leg): As C150 with 50mm wall penetration. D260: Angle fillet trim with 135 and 70mm flanges. D300: Angle fillet trim with 175mm and 70mm flanges. Cross-Section of C/D Trim B230/B260 C100/C100MT/C100L/C100LMT/C150/C150MT/C150L/ D260/D300 25mm Gap Decking and laminate. A warm roof would require a larger B300 trim. B type trim. Cross-section showing chase cut into brickwork with angle grinder. The depth of the chase depends on trim penetration. The C trim is fitted with PU adhesive applied to the back of the trim and is sealed into place with silicone sealant. 25mm gap to allow for expansion of the decking. The D trim is nailed to the deck and remains unattached behind the C trim.

Edge Trim F300/F600/F900 Flat Sheeting The F trim is a flat flashing, mainly used at the intersection of a pitched roof and flat roof often found on dormers. The F trim should not be laminated over completely as it will crack. It is nailed or stapled to the deck and bent up the roof slope. In this situation, the F trim also acts as an expansion facility and must only be fixed to the deck along the bottom edge. There are many other applications for F trim including vertical details where laminating would be time consuming, under the feet of air conditioning units to enable re-roofing without disconnecting, and use on some parapet wall details etc. The trim should be nailed to the deck around its edges and bandaged over any joins or nail penetrations. Any unlaminated trim can be topcoated with the rest of the roof. TRIM DETAILS: F300/600/900: Flat sheeting supplied in 300, 600 and 900mm widths in 20M rolls. AT195 Int/Ext The AT195 Internal and External trim is used wherever the laminate needs to cover an area which continues perpendicular to another laminated surface. The AT195 Ext is supplied with a high-adhesion finish on its outer fascia and should be used for capping applications. The AT195 Int trim is supplied with a high adhesion finish on its outer fascia and should be used for internal corners. The trim should be nailed at both edges if possible. Always bandage over the join between where the nails penetrate the trim and the decking before applying the laminate. These trims are supplied in 3 metre lengths as standard. TRIM DETAILS: AT195 Ext: External angle trim. AT195 Int: Internal angle trim. Cross-Section of F Trim Cross-Section of AT195 Int/Ext Trim 5 F300/F600/F900 AT195 Int/Ext AT195 Int Bandage and laminate AT195 Ext Sarking felt overlaps The first run of tiles is the F300. replaced over the F300. Laminate laid over the edge of the F300.

Edge Trim G180 & E280 Expansion Joint/ Ridge Roll The G180 is used to allow for expansion on large roofs (over 50m 2 ) it also acts as an integral gutter to aid drainage. The decking should be cut to allow for an adequate gap in which to insert the trim and the flanges of the trim should be parallel with the decking. The trim should then be nailed to the decking. The trim edges should then be bandaged and the laminate should be applied over the trim. E280 is used both to create expansion joints on large roofs (over 50m 2 ) and create rolls on any ridge details. It is compatible with C5 closures. An adequate gap in the deck should be cut if necessary, the trim should then be nailed to each end of the decking at 300mm centres. The join over the nails should then be bandaged and the laminate can be applied over the trim. To bond these trims together, or to cap with C5 closures, apply a thin strip of PU adhesive to the inside edge of the overlapping trim and rub into place. TRIM DETAILS: G180: Flush installation expansion joint and gutter. E280: Expansion joint and ridge roll for pitched roofs. Cross-Section of G and E Trim (E280 applied in same way.) S500- Soffit Trim The S500 is used as a fascia trim for concrete roofing or any similar application which requires an over-sized soffit trim. A support batten should be attached to the wall beneath the structure. The trim should be nailed to the decking at 300mm centes and then the underside should be nailed to the batten. The join between where the nails penetrate the trim and the decking should be bandaged over, the laminate can then be applied to the roof and should overlap the edge of the bandage. The laminate should not extend onto the fascia of the trim. TRIM DETAILS: S500: Soffit trim for encapsulating concrete edge detail. G180/E280 Cross-Section of S Trim S500 Laminate Bandage G180 nailed to deck under bandage The trim is incorporated into the laminate. The join between the trim and the decking is bandaged. Concrete Trim edge is bandaged and laminated. The E280 is fixed to the decking at 300mm centres The underside of the trim is nailed to the support batten at 300mm centres.

Edge Trim, Corner and Closure E35/40 Simluated Rolled Lead Joint Used to simulate the appearance of raised rolled lead joints, also provides expansion. The trim should be nailed to the deck at 300mm centres. The joins and nail penetrations should be bandaged before the laminate is laid over the top of the trim. Ensure that the laminate is well consolidated over the top of the trim. The trim is compatible with C6 closures. TRIM DETAILS: E35/40: Simulated lead rolled joint. C1/2/3/4 Corners The application procedure is the same for all the corner trims listed below. The corner should be nailed to the deck at each end and in the middle. The joins between the trim and the corner should be sealed with a thin line of PU adhesive, a moist finger can be used to wipe the adhesive, ensuring it seals the entire joint. The joint is then bandaged over. Tissue should be used to ensure a smooth finish. Corner Trim Details C1 Universal external corner- Compatilble with A200 and B260 profiles. C2 Fillet to trim corner- For the junction of a flat roof and abutting wall. Compatible with A200, B260 & D260. Cross-Section of E35/40 Trim 7 E35/40 C3 Internal/External fillet corner- Pre-formed internal/ external corner for use with D260. Avoids mitring in situe. C4 Universal internal corner- Pre-formed internal left and right hand corners. Compatible with A200 & B260 profiles. Trim nailed to deck at 300mm centres, Laminate C5/6 Closures is the same for all the closure trims listed below. Apply a thin line of PU adhesive to the end of the rolled trim and over lap the closure by at least 50mm and press the trims together firmly to ensure that the adhesive seals the gap nail the trim to the decking and laminate over the completed section. Closure Trim Range C5 roof ridge closure- Compatible wth E280 expansion joint/ridge trims. C6 rolled rib closure- Compatible with E35/40 simulated lead roll trims.

Quick Trim Guide A170 Fascia Trim Girth: 170mm Depth: 65mm Fitted to roof edges to allow drainage. C150 Simulated Lead Flashing Vertical cover: 150mm Replaces traditional lead flashing. Wall penetration: 35mm Dark grey, non-adhesive finish to simulate the appearance of lead. Do not topcoat. AT195Int Internal Angle Trim Girth: 195mm Flange widths: 105 & 85mm High adhesion surface on inner face for forming upstands, gutter floors etc. A200 Fascia Trim Girth: 200mm Depth: 90mm Fitted to roof edge to allow drainage into gutter. Compatible with C1, C2 and C4 corner trims. C150MT Simulated Lead Flashing with Moisture Trap Vertical cover: 150mm Wall penetration: 35mm As C150 with integral self-securing moisture trap. AT195Ext External Angle Trim Girth: 195mm Flange widths: 85 & 105mm High adhesion finish on outer face for step details, cover flashings etc. A250 Fascia Trim Girth: 250mm Depth: 140mm Roof edge detail to cover insulation. Usually used with a warm roof specification. Deep fascia to allow gutter pentration. C150L Simulated Lead Flashing Long Leg Vertical cover: 150mm Wall penetration: 50mm As C150 with deep wall penetration. C1 Universal External Corner Description Hot press moulded GRP pre-formed external corner. For use with A200 and B260 profiles to form a left of right hand corner. B230 Raised Edge Trim Girth: 230mm Flat roof edge detail to prevent Depth: 105mm water run off. Drip matches A170. D260 Wall Fillet Girth: 260mm Fillet: 135 & 70mm Upstand height: 120mm Asymmetric fillet trim for use against abutting walls. Also provides expansion and perimeter ventilation. C2 Fillet to Trim Description Right and left hand mouldings available For use where a flat roof meets an abutting wall. Compatilbe with A200, B260 and D260 profiles. B260 Raised Edge Trim Girth: 260mm Flat roof edge detail to prevent Depth: 125mm water run off. Compatible with C1, C2 and C4 corner trims. D300 Long Flange Wall Fillet Girth: 260mm Extra wide asymmetric fillet for Fillet: 175 & 70mm use against abutting walls. Also Upstand height: 120mm provides expansion and perimeter ventilation. C3 (Int) Internal Fillet Corner Description Internal corner fillet trim. Used as a pre-formed internal corner for D260 fillet trim. Avoids mitring in situe. B300 Raised Edge Trim Girth: 300mm Deep fascia raised edge trim. Depth: 180mm Usually used with a warm roof configuration. Drip matches with A250 trim. E35/40 Simulated Lead Rolled Joint (Rolled Rib) Girth: 130mm Flanges: 20mm Height: 40mm Roll width: 35mm Used to simulate the appearance of raised rolled lead joints. Also provides expansion. Compatible with C6 preformed closures. C3 (Ext) External Fillet Corner External corner fillet trim Used as a pre-formed corner for the D260 fillet profile. Avoids mitring in situe. C100 Simulated Lead Flashing Vertical cover: 100mm Replaces traditional lead flashing. Wall penetration: 35mm Dark grey, non-adhesive finish to simulate the appearance of lead. Do not topcoat. E280 Raised Ridge Roll Girth: 280mm Used as an expansion joint on Flanges: 90mm larger roofs and to create rolls on Height: 50mm any ridge details.compatible with C5 preformed closures. C4 Universal Internal Corner Description Hot press moulded GRP pre-formed internal corner. For use with A200 and B260 profiles to form a left or right hand corner. C100MT Simulated Lead Flashing with Moisture Trap Vertical cover: 100mm Wall penetration: 35mm As C100 with integral self-securing moisture trap. F300/600/900 Flat Flashing Max width: 900mm Min width: 300mm Max length: 20m Flat section for use as continous flashing under slates at a roof junction. It can also be used as a gutter lining. C5 Roof Ridge Closure Description Preformed roof ridge closure. Pre-formed closure for use with E280 profiles. C100L Simulated Lead Flashing Long Leg Vertical cover: 100mm Wall penetration: 50mm As C100 with deep wall penetration. G180 Gulley Trim/Expansion Joint Girth: 180mm Flanges: 30mm Depth: 15mm Trough width: 80mm Used on larger roofs to aid draininge and to ensure gapping of underlying timber to facilitate expansion. C6 ER35/40 Rolled Rib Closure Description Preformed roof ridge Pre-formed closure trim for use closure. with ER35/40 profiles. C100LMT Simulated Lead Flashing Long with Moisture Trap Vertical cover: 100mm Wall penetration: 50mm As C100 with deep wall penetration and integral selfsecuring moisture trap. S500 Soffit Trim Girth: 450mm Depth: 225mm To fully encapsulate a concrete edge or similar roof edge detail.