Better ZSOIL, Better Geotechnical Analysis

Similar documents
Better ZSOIL, Better Geotechnical Analysis

SETTLEMENTS DUE TO TUNNEL CONSTRUCTION

SOIL PRESSURE IN EMBANKMENT STABILIZATIONS

MIDAS ELITE SERIES SOIL STRUCTURE INTERACTION ANALYSIS OF SKYSCRAPER IN BRAZIL RICARDO BORN

Pile foundations Introduction

BEARING CAPACITY IMPROVEMENT USING MICROPILES A CASE STUDY

VOL. 11, NO. 16, AUGUST 2016 ISSN ARPN Journal of Engineering and Applied Sciences

Numerical Analysis of the Durability of Retaining Wall with Anchor

Council on Tall Buildings

Foundation Design with SANSPRO

Numerical Analysis for High-rise Building Foundation and Further Investigations on Piled Raft Design

EFFECT OF DEEP EXCAVATION SUPPORTED BY CONCRETE SOLIDER PILE WITH STEEL SHEET PILE LAGGING WALL ON ADJACENT EXISTING BUILDINGS

Downloaded from Downloaded from /1

Modeling and Design of Bridge Super Structure and Sub Structure

Analysis of skin friction in prebored and precast piles

CCTV Headquarters Case Study. ARCH 631 Haowei Cheng, Peixin Dong, Xiaoying He, Zepeng Jia, Dongqi Zhu

Northport Berth 3 design and construction monitoring

Typical set up for Plate Load test assembly

Experimental study on axial and lateral bearing capacities of nonwelded composite piles based on pile load test results

Integral Bridges and the. Modeling of Soil-Structure Interaction

Two-way slabs. Flat plate with or without drop panels / capitals

Skirted Spudcan Sheet Pile Wall Interaction during Jack- Up Rig Installation and Removal in a Harbour Area

Introduction to Structural Analysis TYPES OF STRUCTURES LOADS AND

Sabah Shawkat Cabinet of Structural Engineering 2017

Three-dimensional computer simulation of soil nailing support in deep foundation pit

Behavior of pile due to combined loading with lateral soil movement

NPTEL Course GROUND IMPROVEMENT USING MICROPILES

Steel screw settlement reduction piles for a raft foundation on soft soil

Advance Design of RC Structure Retaining Wall

STATIC ALTERNATING CYCLIC HORIZONTAL LOAD TESTS ON DRIVEN

A Dynamic Behavioural Study of Structure and Foundation for 25 Storey Structure with Variable Sub-Soils by Time History FEM Model

Modelling of Piled Raft Foundation on Soft Clay

twenty four foundations and retaining walls Foundation Structural vs. Foundation Design Structural vs. Foundation Design

COMPARISON OF MULTISTORY WALL RESULTS BETWEEN ADAPT-EDGE 1 AND ETABS 2 CONCRETE FRAME WITH SHEARWALLS

Full-Ring Experimental Study of the Lining Structure of Shanghai Changjiang Tunnel

Challenges of quick clay excavation in urban area with sloping ground

FULL-RING EXPERIMENTAL STUDY OF THE LINING STRUCTURE OF SHANGHAI CHANGJIANG TUNNEL

OPTIMAL DIAGRID ANGLE TO MINIMIZE DRIFT IN HIGH-RISE STEEL BUILDINGS SUBJECTED TO WIND LOADS

Analysis of Buried Arch Structures; Performance Versus Prediction

Static Response of Reinforced Soil Retaining Walls with Modular Block Facing

UNIT-1 RETAINING WALLS

Office Building-G. Thesis Proposal. Carl Hubben. Structural Option. Advisor: Dr. Ali Memari

twenty six concrete construction: foundation design ELEMENTS OF ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2013

Testing of ground anchorages for a deep excavation retaining system in Bucharest

USE OF DIPP PILES FOR A NEW SUP BRIDGE IN WEST MELBOURNE

Influence of soil properties on the behavior of concrete pavements casted on dome-shaped interface elements

Application Note - Cantilever Stem Wall Analysis

RS 3 A New 3D Program for Geotechnical Analysis

How to model Mohr-Coulomb interaction between elements in Abaqus

SEISMIC SOIL-PILE GROUP INTERACTION ANALYSIS OF A BATTERED PILE GROUP

DESIGN OF MULTILEVEL CAR PARKING BUILDING

Ground Improvement Prof. G. L. Sivakumar Babu Department of Civil Engineering Indian Institute of Science, Bangalore

The experience in applying of static load and O-cell pile testing geotechnologies in problematical soil conditions of Astana

3D EFFECTS OF DIFFERENTIAL SETTLEMENTS ON A SPECIAL MOMENT RESISTING FRAME DUE TO EARTHQUAKE

Ching Guan Kee ABSTRACT

SEISMIC DESIGN OF STRUCTURE

Foundation or Footing Design: Part 1

Analysis and Design of the Kingdom Tower Piled Raft Foundation

twenty seven concrete construction: foundation design Foundation Structural vs. Foundation Design Structural vs. Foundation Design

Foundation Design. π = pi ( radians or 180 ) ρ = reinforcement ratio in concrete beam design = A s /bd µ = coefficient of static friction

Load sharing characteristics of piled raft foundation in clay soil

Test of bored piles and the outcome of the Danish standard for designing bored piles

Journal of Chemical and Pharmaceutical Research, 2013, 5(9): Research Article. Stability analysis of cantilever retaining wall with FEM

COURSE ON COMPUTATIONAL GEOTECHNICS A Geotechnical Design Tool. Faculty of Civil Engineering UiTM, Malaysia

Repute benchmarks. 4 x 4 pile group in firm to stiff clay. Results from Repute. Comparison with benchmark. Comments. Reference.

Example Application 11. Multistage Tunnel Excavation and Support

Analysis of Shear Wall Transfer Beam Structure LEI KA HOU

FOUNDATIONS. Foundations Copyright G G Schierle, 2006 Press Esc to end, for next, for previous slide 1

Example Application 10. Analysis of a Concrete Diaphragm Wall

SOIL-STRUCTURE INTERACTION ANALYSIS OF A RAILWAY BRIDGE IN ROTTERDAM

Marina Bay Sands Hotel Arch 631 Kayla Brittany Maria Michelle

Design Example 2 Reinforced Concrete Wall with Coupling Beams

Prof. Dipl.-Ing. H. Quick Ingenieure und Geologen GmbH provides geotechnical engineering services e. g. for high-rise buildings in Germany and abroad.

Evaluation of negative skin friction on sheet pile walls at the Rio Grande dry dock, Brazil

210 Prescott Street, Unit 1 (613) P.O. Box 189 Kemptville, Ontario K0G 1J0 FAX: (613) May 5,

Seismic Performance of Piled Raft Subjected to Unsymmetrical Earth Pressure Based on Seismic Observation Records

Effect of Particle Size Distribution of Cohesionless Soil and Pile Diameter on the Behavior of Open Ended Pipe Piles

Relationship between twin tunnels distance and surface subsidence in soft ground of Tabriz Metro - Iran

Finite Element Study Using FE Code (PLAXIS) on the Geotechnical Behavior of Shell Footings

GEO-SLOPE International Ltd, Calgary, Alberta, Canada Tie-back Wall

Code No: RR Set No. 1

The SP Suite has the capability to design an entire concrete structure from foundation to roof. These programs are based on the methods, equations,

Dubai Tower Piled Raft Foundation

Introduction to. Asian Center for Engineering Computations and Software. ACECOMS & AIT Solutions 1

BEHAVIOR OF STEEL FRAMES WITH AND WITHOUT AAC INFILLED WALLS SUBJECTED TO STATIC AND CYCLIC HORIZONTAL LOADS

Council on Tall Buildings. and Urban Habitat BACKGROUND SECTION STEEL REINFORCED CONCRETE SHEAR WALL STEEL PLATE COMPOSITE SHEAR WALL

Example of the Unified Design procedure for use in the September 8, 2014, short course on in Brazil

Non-linear Time History Response Analysis of Low Masonry Structure with tie-columns

Development of New-type Steel-Pipe Methods for Urban Renewal Projects

CCTV HEADQUARTERS. ARCH 631 Spring 2018 Daniel Edith Mckenzie Rafael

Design Illustrations on the Use of Soil Nails to Upgrade Loose Fill Slopes

Braced deep excavations in soft ground

ANALYSIS OF BUILDINGS WITH

ACCURATE LINEAR AND NONLINEAR SEISMIC SSI ANALYSIS BASED ON ANSYS FE MODELING USING EXTENDED SASSI METHODOLOGY

Earthquake Design of Flexible Soil Retaining Structures

NPTEL Course. GROUND IMPROVEMENT Factors affecting the behaviour and performance of reinforced soil

Centrifuge Model Tests on Settlement Controlling of Piled Raft Foundation in High-Rise Building

Reinforced Concrete Spread Footing (Isolated Footing) Analysis and Design. Design Footing

Sabah Shawkat Cabinet of Structural Engineering 2017

Combined footings A mat or raft or floating foundation Pile caps

Transcription:

SYMPOSIUM : NUMERICS IN GEOTECHNICS & STRUCTURES 26 YEARS ZSOIL.PC DATE :1-2.09.2011 Better ZSOIL, Better Geotechnical Analysis Practice of Pile Foundation Treatment Based on ZSOIL.PC YIN JI 1,2 Email:sh_geofem@hotmail.com 1.Shanghai Geotechnical Investigation & Design, co,.ltd. 2.GEOFEM

CONTENTS Functions related to Pile Foundation Design of ZSOIL.PC Pile element Borehole Nodal link Practice of Pile Foundation Treatment General information Challenge Pile static load test 3D FEM analysis Acknowledgements

Functions related to Pile Foundation Design of ZSOIL.PC Pile element Borehole Nodal link

Functions related to Pile Foundation of ZSOIL.PC Pile element Raft or trip foundation Shear interface Pile/Beam Mechanical Features of Pile element Pile element contains pile (structure element ), lateral skin shear interface and toe compaction/tension interface The interaction between pile and surrounding soil can be modeled with skin and toe interface, which comply with Mohr-Coulomb strength criterion Pile (structure element ) inherits all the properties of beam element Compaction/te nsion interface

Functions related to Pile Foundation of ZSOIL.PC Pile element Raft foundation Pile head Pile element Modeling of Pile element Hundreds of pile elements can be generated on objects within several seconds, which usually imported from DXF files Pile head can be automatically link to raft or trip foundation smartly, which can save us many hours to merge pile head and nodes of solid element Axial force, moment and shear force can transfer from piles to raft, and vice versa The length of each segment of pile should be compatible with the length of the soil element, not too large nor too small If layout of piles change, import the modified DXF file again

侧摩阻力 (kpa) 180 160 140 120 100 80 60 40 20 0 Functions related to Pile Foundation of ZSOIL.PC Pile element Skin force of pile C1013 C1354 C1882 S22 Average stiffness Ultimate Strength 桩身位移 (mm) 0 2 4 6 8 10 12 14 Shear displacement Determine the strength and stiffness of skin interface Parameters of pile element Parameters of pile (structure) is easy to determine when the style of pile is selected Parameters of skin and toe interface can inherit from surrounding soil. Default settings of the program can cope with most of the situation, however, accuracy is not too high In-site test, like pile static load test with strain gauge set in different depth of pile, is necessary for fine analysis of pile foundation. We can gain strength and stiffness of skin interface though diagraph of shear displacement vs. skin force To comply with design code, zero friction angle of pile skin interface is necessry

Functions related to Pile Foundation of ZSOIL.PC Borehole Complex spatial distribution of soil Borehole function helps to generate complex spatial distribution of soil material easily without 3D surface generated. It is convenient to add boreholes any time to update spatial distribution, which can save us many hours too

Functions related to Pile Foundation of ZSOIL.PC Borehole + Pile element All for the sake of Engineers Step 1: hide all the soil above the bearing layer of pile Step 2: select visible faces, then all the face of bearing layer is selected Step 3: Macro model\point\project\on selected faces in direction, then all the pile toes stand on the bearing layer Step 4: move the pile toes some distance into the bearing layer if necessary It is very convenient to stick hundreds of piles on the bearing layer

Functions related to Pile Foundation of ZSOIL.PC Nodal link Set the mind free Super structure can be connected to the foundation by nodal link, without compatible mesh Very fine structure model can be avoided, which will significantly increase the number of the elements of the whole model Structure model can be established in another file.it can be assembled with soil and foundation when necessary.

Practice of Pile Foundation Treatment General information Challenge Pile static load test 3D FEM analysis

General information Information of super structure Frame shear wall structure, 26F(105m), basement 2F(16.5m depth) This building will be discussed

General information Information of pile Pre-stressed concrete pipe pile(phc), diameter 500mm, thickness 125mm, length 30.0m(segment I :15m + segment II :15m), bearing capacity 2500kN Static piling method is used to drive the pile Ground surface,+30.86m Bottom of basement,+13.86m Pile length, 30m Static driving machine Bottom of pile,-16.14m PHC500, 15m length per segment

General information Layout of piles 594 PHC piles are employed to support the gravity of the building grid type layout is used, for the bearing capacity of each pile is not high enough The distance between two neighboring piles is 2.0m, which is the min. pile spacing according to the code for Chinese pile foundation

General information Information of geology conditions The site is mainly composed of silty clay (N/SPT=10~12, Ps/CPT= 1.5~2.5Mpa) and middle sand (N/SPT=22~30, Ps/CPT= 10.0~15.0Mpa) silty clay Sand, hard to penetrate Pile head level pile gravel, hard to penetrate Pile toe level

Challenge According to the construction records, 200+ piles are shorter than design length (30m) Irregularly distributed hard layer may be the reason 7.0 7.5 7.0 6.8 6.8 6.9 6.9 7.2 7 7 7 7.1 7.1 7 7 6.7 6.7 6.9 6.8 6.3 6.9 6.8 6.8 6.7 6.8 6.8 7 7 7 6.2 6.2 6.9 6.9 6.6 6.8 6.1 7 7 7 7 7.4 7.1 7 7 7 7 7.2 7.2 7.3 6.4 6.4 6.5 6.8 6.6 6.3 6.7 7.2 7.2 7.2 7.5 7.1 7.2 7.1 7.3 6.6 6.8 7.5 7.6 7.5 7.5 7 7.2 7.2 7.6 7.7 7.1 7.2 7.4 7.2 7.2 6 7.6 7.8 7.7 7 7.1 7.2 7.1 6.9 6.8 7.7 7.7 7.5 7.5 7.3 7.5 7.4 7.3 6.3 6.3 6.3 6.4 6.9 7.5 7.6 7.3 7.3 7.4 7.3 6 6 7.5 7.4 7.3 7.5 7.4 7.5 7.3 6.8 6.7 6.7 6.4 6.5 6 6.6 79 piles are 7~8m shorter than design length 49 piles are 6~7m shorter than design length

Challenge 4.2 4.1 4.5 5.9 5.3 5.1 5.5 5.9 4.2 4.2 4.1 4 5.5 4.5 4 6.2 4.2 5.5 5.5 5.5 5.4 4.3 5.3 5.3 5.5 4.5 8 4.7 4.6 4.5 4.4 4.5 4.5 5.5 5.5 5.6 5.8 5.3 5.6 5.6 5.4 5.3 5.7 5.1 5.7 4.3 28 piles are 5~6m shorter than design length 18 piles are 4~5m shorter than design length

Challenge 2.4 2.5 2.6 2.4 2.9 2.4 3.7 3.7 3.9 2.7 2.4 2.4 2.3 2.9 2.8 2.9 3.2 3.9 3.2 2.6 2.3 2.7 2.3 2.9 3.2 2.5 2.1 3.0 3.2 3.1 3.1 3.3 3.4 3.4 3.3 3 2.6 2.7 2 2.1 3.4 3.2 3.1 2.9 3.3 2.1 3.4 3 2.4 2.3 2.7 2.8 2.8 2.7 2.7 2.8 2.7 2.8 2.7 2.9 3.1 3.2 2.8 2.8 2.1 3.6 3.4 3.7 3.5 3.6 3.4 3 3.1 2.9 2.8 3.2 3.7 3.6 3.1 3 3 3 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 39 piles are 3~4m shorter than design length 61 piles are 2~3m shorter than design length

Challenge It seems impossible to drive additional piles into the ground to compensate the lack of bearing capacity. There is no room left, even for only 1 pile. It seems impossible to move to another site to construct the building. Kidding? Maybe our client has to reduce the height of the building. maybe With so many short piles, is the foundation safe enough to support the load of the building?

Challenge How to help our client? We need to know the exact load applied to each pile. Super structure-foundation-soil interaction theory can be employed to calculate the load of each pile. Pile static load test can be used to determine the real bearing capacity of piles with different length, especially the shortest piles. We can judge the safety factor of each pile. We can calculate the settlement of the building.

Pile static load test We select 7.0~8.0m shorter piles to implement pile static load test. If the bearing capacity of the shortest piles is OK, of course,the capacity of other piles will be OK. Pile static load test Steel beam Hydraulic jacks

Pile static load test settlement (mm) 0 10 20 30 40 7m shorter 0 1000 2000 3000 4000 5000 Load (kn) Three 7.0m shorter piles are selected to test. We select the shortest piles to represent the whole piles. According to the diagraph of load vs. settlement, the max. load of the test is about 4750kN. The current bearing capacity of the tested pile is 4750/2=2375kN. The design bearing capacity is 2500kN. The current bearing capacity is about 5% smaller than the design value. Is the current bearing capacity enough? What the 3d FEM analysis tell us?

3D FEM analysis Some details should be considered in the analysis The effective length of the piles,bearing layer and the depth into the bearing capacity are very different. The distribution of stiffness of the super structure will affect the settlement value. The distribution of stiffness of the super structure will affect distribution of the settlement of the foundation. The thickness of the raft will play the positive role of the settlement compatibility between raft and piles.

3D FEM analysis We implement the below when establish FEM model Pile element is used to model PHC pile. Pile skin and toe interface are considered. The length of pile is set according to the construction record. For the convenience of modeling, piles are classified to 7m, 5m and 3m shorter than design value. Borehole method is used to determine the spatial distribution of soil layer. Mohr-coulomb model is used to descript soil mechanical behavior. The geometry of frame column and shear wall is set strictly according to the structural design. The load applied to frame column and wall is set strictly according to the structural analysis result.

3D FEM analysis Load applied on wall and Frame column according to structural calculation result

3D FEM analysis Frame column and wall are connected to floor with nodal link Shear wall floor floor Frame column wall

3D FEM analysis Raft Piles with different length(7m,5m,3m shorter than design length) Bearing layer of piles

3D FEM analysis Max. settlement is about 5.85cm, which occurs at the corner of the shear wall core tube. This maybe the result of piles of different length and irregularly spatial distribution of bearing layer. Min. settlement is about 2.90cm. Max. settlement difference is about 2.95cm. Taking into account the width of the raft(30m), the inclination of the building is about 0.1%. The max. settlement and the inclination of the building meet the requirements of the standard (GB50007-2002).

3D FEM analysis Axial force of pile head range from 520 to 2200kN. The average value is about 950kN. According to the pile static load test, the calculated axial force of pile head (working load) is below the bearing capacity(2375kn). The distribution of axial force of pile head is very different from our experience. According to our experience, max. axial force of pile head usually occurs at corner and edge of the raft. This maybe the result of piles of different length and irregularly spatial distribution of bearing layer.

3D FEM analysis Analysis Summary According to 3D Fem analysis, the bearing capacity of short piles, the settlement and inclination of the building can meet the requirement of Chinese foundation standard ( code for design of building foundation GB50007-2002). It is necessary to conduct super structure-foundation-soil interaction analysis for irregularly spatial distributed soil layer and piles with different length. Sometimes, experience from horizontally stratified ground can not be transplanted to irregularly spatial distributed soil layer. It is too conservative to design pile foundation without consideration of the contribution of raft. With the help of the method mentioned above, we can optimize the design of pile foundation.

Acknowledgements Thanks to the development team of ZSOIL.PC help from ZACE since 2011/01/03

For some reasons, not all of the details is published in the PPT. Ideas maybe important than numbers for geotechnical engineers. YIN JI Email:geofem@126.com