BioPro IEX Resins. Resin Downstream Purification

Similar documents
BioPro SmartSep. Benefits of using BioPro SmartSep. Product information

YMC-BioPro NEW. porous and nonporous IEX columns. For the analysis and separation of peptides, proteins and biomolecules

TOYOPEARL GigaCap Series

TOSOH BIOSCIENCE. Hydrophobic Interaction Chromatography. How hydrophobic do you want to go? Separations Business Unit

TSK-GEL BioAssist Series Ion Exchange Columns

Ion Exchange Chromatography Media. Cellufine IEX. Technical Data Sheet

HYDROPHOBIC INTERACTION CHROMATOGRAPHY TOSOH BIOSCIENCE

Fast protein separations with ion exchange columns

Column for High Performance,High-Binding Capacity Ion Exchange Chromatography:TSKgel SuperQ-5PW and Its Applications

Size Exclusion BioHPLC columns Ion Exchange BioHPLC columns

Separation of Monoclonal Antibodies Using TSKgel HPLC Columns

Purification of oligonucleotides by anion exchange chromatography

Q and S HyperCel Sorbents

TechnicalNote. BAKERBOND Multimode Ion Exchange Chromatography Media. Introduction. BAKERBOND PolyPEI

Table 1, Performance characteristics of Cellufine SPA-HC

2010 Tosoh celebrates its 75th year in business with the opening of five new plants, and continued rapid expansion in china

DexS-HbP. Technical Note Heparin Mimetic Affinity. Model Protein adsorption to Cellufine MAX DexS-HbP resin

HyperCel STAR AX Ion Exchange Sorbent

The Selectivity Company. YMC Glass Columns. For Laboratory Scale Applications. Biocompatible Self-packing Easy Handling.

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

Cellufine MAX HIC Butyl, Phenyl Technical Data Sheet

SOURCE 15HIC. GE Healthcare. SOURCE 15ETH, SOURCE 15ISO, SOURCE 15PHE, SOURCE 15PHE 4.6/100 PE (Tricorn ), Characteristics

WorkBeads Protein A INSTRUCTIONS IN

Faster Separations Using Agilent Weak Cation Exchange Columns

Capture of mouse monoclonal antibodies

HyperCel STAR AX Ion Exchange Sorbent

Column Packing of Cellufine A-500 ion exchange chromatography resin

Analysis of biomolecules by SEC and Ion-Exchange UPLC

TOSOH FACT The Tosoh logo symbolizes the corporate philosophy of Tosoh s vision of the ideal. The curved lines represent the realization of

The Eshmuno Chromatography Family of Resins

Optimizing Protein Separations with Agilent Weak Cation-Exchange Columns

Application Note USD Purification of Mouse IgM from Cell Culture Supernatant by Cation Exchange Chromatography on CM Ceramic HyperD F Sorbent

SOURCE 15Q, SOURCE 15S, and prepacked column formats

Polishing of monoclonal antibodies using Capto S ImpAct

Phenyl Membrane Adsorber for Bioprocessing

Bio-Works products. Research & Laboratory Process Development Bioprocess Production

Capto Blue and Capto Blue (high sub)

HiTrap convenient protein purification

1. Connect the column to the chromatography system, syringe or pump.

TSKgel STAT Columns for High Performance Ion Exchange Chromatography

Agilent Prep LC Columns for Small Molecules and Biomolecules MAINTAIN RAPID, RELIABLE SEPARATIONS AS YOU SCALE-UP

Use of ScreenExpert RoboColumns u

... Macro-Prep 25 Ion Exchange Supports. Instruction Manual

Mimetic Blue Affinity Adsorbents Mimetic Blue 1 P6XL, Mimetic Blue SA P6XL Mimetic Blue SA HL P6XL, Mimetic Blue ELISA Kit

Technical Data. Analytical Data

Chapter 1 Principles of ion exchange

Capacity and performance of MabSelect PrismA protein A chromatography resin

G-Sep Ion Exchange Agarose Fast Flow

G-Sep Ion Exchange Agarose Fast Flow

Phenyl Membrane Adsorber for Bioprocessing

Chromatography column for therapeutic protein analysis

Userguide: SepFast Gel Filtration columns

2012 Waters Corporation 1

Next Generation Zirconia-Based Antibody Purification Media

Nuvia S and Q High-Capacity Ion Exchange Media Instruction Manual

3. Close the bottom end of the column and apply the packing device on top. Pump water through the upper adaptor to remove air.

Superdex 200 Increase columns

Capto * Blue and Capto Blue (high sub)

Nuvia HR-S Strong Cation Exchange Media Instruction Manual

Bivalirudin Purification:

GORE. Protein Capture Devices. Operating Instructions Contents. Product Description Device Characteristics... 2 General Handling...

UNOsphere Q & S Ion Exchange Media. Instruction Manual ...

Superdex 200 Increase columns

Capture of human single-chain Fv (scfv) fusion protein on Capto L affinity medium

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

Capto S, Capto Q, and Capto DEAE

Optimization of the Effective Separations for Peptides and Proteins Using High Durable Packing Materials for HPLC. YMC CO., LTD.

MabSelect Xtra. GE Healthcare. Recombinant protein A-based, high-capacity affinity medium. Medium characteristics Description

Operating Instructions Heparin Mimetic Affinity

Phenyl Sepharose High Performance

Physical Stability of a Silica- Based Size Exclusion Column for Antibody Analysis

Convenient Purification of Monoclonal Antibodies using HiTrap rprotein A FF

Q SepFast HighRes. DEAE SepFast TM HighRes S SepFast TM HighRes CM SepFast TM HighRes

Phenyl Sepharose High Performance Butyl Sepharose High Performance

Data File. HiLoad Superdex 30 prep grade HiLoad Superdex 75 prep grade HiLoad Superdex 200 prep grade. Pre-packed gel filtration columns

MabSelect SuRe. GE Healthcare. Alkali-stabilized protein A-derived medium for capture of monoclonal antibodies. High stability in alkaline conditions

Fast Agilent HPLC for Large Biomolecules

ION EXCHANGE KIT FOR MAB SEPARATIONS

The above media is designed to capture antibodies or other molecules of similar size.

HiScreen prepacked columns

BabyBio S BabyBio Q BabyBio DEAE

Protein A Mag Sepharose Xtra Protein G Mag Sepharose Xtra

Alkali Resistant and Optimized Ligand for High Capacity Surface Modified Base Bead for High Purity Semi-rigid Bead for High Productivity

Alkali Resistant and Optimized Ligand for High Capacity Surface Modified Base Bead for High Purity Semi-rigid Bead for High Productivity

Capto Q Capto ViralQ Capto S

HiTrap NHS-activated HP

columns P r o P a c H I C C o l u m n S o l u t i o n s f o r P r o t e i n A n a l y s i s

The above media is designed to purify antibodies from aggregates and other impurities.

High Throughput Sub-4 Minute Separation of Antibodies using Size Exclusion Chromatography

G Trap Ion Exchange Selection Kit

Size Exclusion BioHPLC Columns

Nonionic Polymer Enhancement of Aggregate Removal in Ion Exchange

POROS Perfusion Chromatography Media

Ab SpinTrap Ab Buffer Kit

An effective platform for purification of IgM monoclonal antibodies using Hydroxyapatite

SOURCE 15Q and SOURCE 15S

Phenyl Sepharose CL-4B

MabSelect. GE Healthcare. Characteristics

Chromatography Media. Technical Data Sheet. Life Chemicals Launch Office

Superdex 200 HR 10/30 INSTRUCTIONS

Transcription:

BioPro IEX Resins Resin Downstream Purification

2 BioPro: Designed for bioseparations

Contents 3 Introduction...4 Guide to IEX Media Selection...5 Specifications...7 Solutions for Capture Processes...9 Solutions for Intermediate Purification and Polishing...15 Purification of Monoclonal Antibodies...23 Ordering Information...28

4 Introduction Ion exchange (IEX) media is widely used in the analysis and purification of biomolecules. For instance, in industrial-scale protein production processes, IEX media are often used for initial product capture and intermediate purification stages as well as the final polishing steps. Using reversible charge-charge interactions offers several advantages over in comparison to other chromatographic methods, e.g. high capacity and fast throughput. BioPro and BioPro SmartSep form a series of ion exchange resins specifically designed for biochromatography. It is available as a strong anion exchanger (BioPro Q) and a strong cation exchanger (BioPro S). The media is based on a hydrophilic polymer matrix, with a particle size of 10 µm, 20 µm, 30 µm and 75 µm. BioPro resins with a 75 µm particle size are especially suited for the initial capture step while the BioPro SmartSep 10 µm, 20 µm, 30 µm are the ideal choices for the intermediate purification and polishing processes. BioPro is manufactured in lot sizes up to 450 L. BioPro Ion Exchange Type Strong anion exchanger, strong cation exchanger Particle Size 75 µm BioPro SmartSep Ion Exchange Type Strong anion exchanger, strong cation exchanger Particle Size 10 µm, 20 µm, 30 µm BioPro series media provide: Solutions for challenging separations Increased productivity Reduced processing costs Worldwide availability, even for large quantities Full compliance with FDA regulations

Guide to IEX Media Selection 5 Selection of the media chemistry The separation with IEX Media is based on the net surface charge of the analytes in relation to the ph of the surroundings. The theory for selection of an anion exchanger or a cation exchanger is shown in the figure below. + Isoelectric point (PI) If the system ph is above PI, select anion exchanger Net Charge of Protein 2 4 6 8 10 12 If the system ph is below PI, select cation exchanger ph BioPro series products are polymeric ion exchange media for the purification of biological molecules. They are available in Q and S chemistries. BioPro QA H CH 3 C N CH 3 H CH 3 + Strong anion exchanger BioPro SP H C n SO 3 H Strong cation exchanger N.B.: Fully porous particles

6 Guide to IEX Media Selection The selection of the particle size of the media depends on the purification purpose. A purification strategy usually includes three parts: initial product capture intermediate purification stages the final polishing step Each step has correspondingly different targets and requirements for the chromatography media. The capture step aims at isolating and concentrating the targets. It requires that the media have high binding capacity even at high flow rate and easy scale-up steps. The intermediate purification is for removing the bulk impurities while the polishing step is for removing all trace impurities. The corresponding media should exhibit high resolution and low non-specific adsorption. IEX resins are used during the whole process from the capture to the final polishing. Bio- Pro media are designed for capture step of biopharmaceuticals and BioPro SmartSep media are for intermediate purification and polishing steps of biopharmaceuticals. Capture BioPro 75 µm YMC IEX Media Intermediate purification BioPro SmartSep 10, 20, 30 µm Polishing BioPro SmartSep 10, 20, 30 µm

Specifications 7 BioPro for Capture BioPro Series BioPro Q75 BioPro S75 Ion exchange type strong anion exchanger strong cation exchanger Charged group -R-N + (CH 3 ) 3 -R-SO 3 - Matrix Pore size Hydrophilic polymer beads Porous Compression factor 1.05-1.15 Particle size 75 µm Pressure resistance Typical flow rate Ion-exchange capacity Dynamic binding capacity 0.3 MPa 200-1000 cm/hr Max. 2000 cm/hr min. 0.10 meq/ml-resin min. 160 mg/ml-resin (BSA) Regulatory support file available under non-disclosure agreement. Used in validated cgmp-manufacturing processes. Customised material available on request. DMF registered with FDA. BioPro SmartSep for intermediate purifications and polishing BioPro Series BioPro SmartSep Q10 BioPro SmartSep Q20 BioPro SmartSep Q30 BioPro SmartSep S10 BioPro SmartSep S20 BioPro SmartSep S30 Ion exchange type strong anion exchanger strong cation exchanger Charged group -R-N + (CH 3 ) 3 -R-SO 3 - Matrix Pore size Hydrophilic polymer beads Porous Compression factor 1.05-1.15 Particle size 10 µm 20 µm 30 µm 10 µm 20 µm 30 µm Pressure resistance Regular use: 3 MPa Max.: 4 MPa Regular use: 2 MPa Max.: 3 MPa Regular use: 3 MPa Max.: 4 MPa Regular use: 2 MPa Max.: 3 MPa Typical flow rate 200-1000 cm/hr Max. 2000 cm/hr Ion-exchange capacity Dynamic binding capacity min. 0.08 meq/ml-resin min. 100 mg/ml-resin (BSA) min. 0.08 meq/ml-resin min. 100 mg/ml-resin (lysozyme)

8 Solution for your capture process: BioPro 75 µm

BioPro Ion Exchange Resin 9 BioPro ion exchange resins are designed for the capture step of peptides, proteins and nucleotides on the laboratory and industrial scales. The materials offer high dynamic binding capacity, together with low non-specific adsorption and excellent recovery. The narrow particle size distribution and the low operating pressure enable the materials to work even at high flow rates. Excellent dynamic binding capacity (DBC) Low non-specific adsorption and high recovery High capacity with low operating pressure even at high flow rates Full compliances with GMP requirements Short delivery for industrial-scale quantities Reduced processing costs Scale up and availability The BioPro series includes prepacked columns with 5 µm porous and non-porous resins for fast analysis, and bulk materials up to 75 µm porous beads for purification and capture. The 5 µm porous type and bulk media have similar retention selectivity which allows for predictable scale-up process. The bulk media are available in quantities up to several thousand litres. Mission Statement YMC will never knowingly change any product that is being used in a validated production process or validated analytical method.

10 High Dynamic Binding Capacity (DBC) High binding capacity and high recovery The porous versions of BioPro show high dynamic binding capacity and excellent recovery, making them useful for preparative separations of proteins and antibodies. : BioPro S75 (75 µm) : Tosoh Gigacap S-650M (50 ~ 100 µm) : GE Capto S (90 µm) Column: BioPro S75, 50 x 5.0 mm ID Sample: 1.0 mg/ml Lysozyme in equilibration buffer Eluent: A) 20 mm Glycine-NaOH (ph 9.0) B) 20 mm Glycine-NaOH (ph 9.0) containing 0.5 M NaCl Detection: UV at 300 nm High sample loading at high flow rates has been determined by the dynamic binding capacity of an ion exchange resin. The dynamic binding capacity of BioPro is excellent even at high flow rates. When compared to similar competitor products it consistently exhibits a higher dynamic binding capacity. This results in higher sample loading in your preparative processes. BioPro S75 Particle BioPro S75 Particle

Excellent Performance Applications 11 Two step purification of IgY to produce reference standard material from crude egg yolk extract* Crude extract from egg yolk containing IgY IgY (MW 170 kda) Crude extract is the supernatant after precipitation of the lipids and lipoproteins from egg yolk. L chain (MW 23 kda) H chain (MW 65 kda) Step 1: Capture purification by IEX BioPro Q75, 75 µm mv 500 400 300 200 100 Sample Column Eluent 0 0 10 20 30 40 50 60 min : Crude extract from egg yolk : BioPro Q75, 75 µm, 50 x 4.6 mm ID : A) 20 mm Tris-HCl (ph 8.1) B) 20 mm Tris-HCl (ph 8.1) containing 0.5 M NaCl Gradient : 10% B (0-15 min), 30% B (15-30 min), 90% B (30-40 min) Flow rate : 0.5 ml/min (180 cm/hr) Temperature : ambient Detection : UV at 280 nm Injection : 1 ml (approx. 20 mg protein) Step 2: Final purification by SEC YMC-Pack Diol-200, 5 µm mv 100 75 50 25 0 Sample Column Eluent Flow rate 0 5 10 15 20 25 30min : Fraction from capture purification by IEC : YMC-Pack Diol-200, 5 µm, 300 X 8.0 mm ID : 0.1 M KH 2 PO 4 -K 2 HPO 4 (ph 6.9) containing 0.2 M NaCl : 0.7 ml/min (180 cm/hr) Temperature : ambient Detection : UV at 280 nm Injection : 1 ml (approx. 0.45 mg IgY) SDS-PAGE analysis of crude and purified fraction MW (kda) Non-reduced SDS-PAGE 1 2 3 4 5 97 66 45 IgY MW (kda) 205 116 97 80 66 55 45 SDS-PAGE 1 2 3 4 5 Lane 1: Marker (containing SDS) 2: Crude extract 3: IEX IEC fraction 4: SEC fraction 5: Standard IgY H chain 29 20 14 30 21 14 6.5 L chain SEC analysis of crude and purified fraction Crude extract A090826A IEX fraction A090824J SEC fraction IgY Purity <15% Purity 53% Recovery 40% Purity >99% Recovery 23% A090826E 0 5 10 15 20min Column Eluent Flow rate Temperature Detection high achievement : YMC-Pack Diol-200 300 X 4.6 mm ID : 0.1 M KH 2 PO 4 -K 2 HPO 4 (ph 6.9) containing 0.2 M NaCl : 0.23 ml/min : ambient : UV at 280 nm * Application data by courtesy YMC Co., Ltd.

12 Cleaning-In-Place (CIP) Performance Test protocol Separation of standard proteins Determination of DBC and recovery CIP with 1.0 M NaOH (5 CV at 400 cm/hr) Column: BioPro S75, 50 x 5.0 mm ID Conditions for standard protein separation Eluent: A) 20 mm NaH 2 PO 4 -Na 2 HPO 4 (ph 6.8) B) 20 mm NaH 2 PO 4 -Na 2 HPO 4 (ph 6.8) containing 0.5 M NaCl Gradient: 0-100% B (0-60 min, Linear) Flow rate: 0.59 ml/min (180 cm/hr) Temperature: 25 C Detection: UV at 220 nm Injection: 24 µl Conditions of DBC determination Eluent: A) 20 mm Glycine-NaOH(pH 9.0) B) 20 mm Glycine-NaOH(pH 9.0) containing 0.5 M NaCl Flow rate: 2.62 ml/min (800 cm/hr) Sample: 1.0 mg/ml Lysozyme in equilibration buffer Temperature: ambient (25 C) Detection: UV at 300 nm DBC determined at 10% breakthrough. CIP Performance Separation of standard proteins* DBC and recovery* BioPro is well suited for alkaline CIP procedures. The dynamic binding capacity (DBC) and the selectivity are unaffected by 20 cycles of CIP with 1.0 M NaOH. The recovery of proteins is maintained at 100%, which demonstrates the absence of nonspecific adsorption of proteins by this hydrophilic resin. * Application data by courtesy YMC Co., Ltd.

Stability in Alkaline Conditions* 13 BioPro Q75 Packed into 50 x 5.0 mm ID Immerse gel in NaOH (1 M) (2-6 hours) Packed into 50 x 5.0 mm ID Column performance Flush with NaOH (1 M) 0.2 ml/min, 2 hours Flush with water to remove NaCl Column performance repeat Exposure to 1 M NaOH solution Flushing with 1 M NaOH solution tr (Trypsin inhibitor) min 44 42 40 38 36 34 32 30 0 1 2 3 4 5 6 Exposure time (h) 0 20 40 60 80 NaOH (CV) Column performance test conditions Eluent: A) 20 mm Tris-HCl (ph 8.1) B) 20 mm Tris-HCl (ph 8.1) containing 0.5 M NaCl Gradient: 10-80% B (0-60 min) Flow rate: 0.5 ml/min Temperature: 25 C Detection: UV at 220 nm Sample: Trypsin inhibitor, Transferrin Injection: 40 µl Stability towards alkaline conditions is essential for efficient sanitizing procedures in a highly regulated environment. BioPro media show excellent tolerance towards challenging alkaline conditions. Stability testing demonstrates that 0.1M NaOH is suitable for long term storage of BioPro. The high chemical stability of BioPro resins allows effective cleaning with alkaline solution and the longevity this material ensures efficient and economic purifications. * Application data by courtesy YMC Co., Ltd.

Solution for intermediate purification and polishing: BioPro SmartSep -- -- - -- -- -- - -- - -- - -- application + + ++ + + ++ + + ++ + + + ++ + ++++ ++ ++ + + ++ ++ ++ + ++ ++ + + + +++ + + + + + + -- -- -- + + + +++ + + -- -- -- -- -- + + + + + + + +++ + + -- -- -- -- -- -- -- + + + + -- -- -- separation elution ++ ++ ++ ++ ++ ++ ++ ++ ++ + + + + + + + + + + ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ + + + + + + + + + + % salt concentration weakly negative charged -- highly negative charged + weakly positive charged ++ highly positive charged % salt % salt t t

BioPro SmartSep Ion Exchange Resin 15 BioPro SmartSep 10 µm, 20 µm and 30 µm resins are the ideal choices for the intermediate purification and polishing processes. With its small particle size, BioPro SmartSep 10 µm provides extraordinary high resolution. BioPro SmartSep 20 µm and 30 µm have been widely used in industrial production process. Solution for challenging separations Increase productivity Reduced processing costs Short delivery time for industrial-scale quantities Full compliance with GMP regulations Examples of possible preparative applications of YMC BioPro SmartSep resins are: Antibody purification Protein purification Peptide purification Oligonucleotide purification

16 High Dynamic Binding Capacity (DBC) Comparison of the Performance of BioPro SmartSep and Competitors Products in the Purification of Lysozyme, Insulin and Polyclonal lgg DBC (mg/ml-resin) 130 120 110 100 90 80 70 60 50 40 = BioPro SmartSep S30 = TSKgel SP-3PW = GE Source 30S 30 0 200 400 600 800 1000 1200 Linear flow rate (cm/hr) Pressure monitoring Pressure (MPa) 0,25 0,2 0,15 0,1 0,05 = BioPro SmartSep S30 = TSKgel SP-3PW = GE Source 30S 0 0 200 400 600 800 1000 1200 Linear flow rate (cm/hr) Column: 50 x 5.0 mm ID Equilibration buffer: 20 mm Glycine-NaOH (ph 9.0) Linear velocitiy: 200-1,000 cm/hr (0.66 ml/min-3.27 ml/min) Comparison of DBC for lysozyme (left) and column pressure (right) at different flow rate. BioPro SmartSep shows considerably higher DBC across a wide range of linear velocity. A high DBC at flow rates of up to 1,000 cm/hr can reduce process time and increase productivity.

High Dynamic Binding Capacity (DBC) 17 Column: 50 x 5.0 mm ID Equilibration buffer: 20 mm Glycine-NaOH (ph 9.0) Linear velocitiy: 200-1,000 cm/hr (0.66 ml/min-3.27 ml/min) Comparison of BioPro SmartSep S30 and competitor s DBC for human polyclonal lgg at different flow rates. BioPro SmartSep shows considerably higher DBC across a wide range of linear velocity. A high DBC at flow rates of up to 1,000 cm/hr can reduce process time and increase productivity. BioPro SmartSep S30 particles

18 High Dynamic Binding Capacity (DBC) 120 100 80 DBC (mg/ml gel) 60 40 20 0 Insulin (MW : 5,800) Lysozyme (MW : 14,300) Human Polyclonal lgg (MW : 150,000) Column: 50 x 5.0 mm ID Flow rate: 400 cm/hr (1.32 ml/min) Temperature: 25 C BioPro SmartSep S30 TSKgel SP-3PW GE SOURCE 30S Comparison of BioPro SmartSep S30 and competitor s DBC for lysozyme, insulin and polyclonal lgg. BioPro SmartSep shows higher dynamic binding capacity for both small peptides and large proteins.

High Resolution and Recovery 19 BioPro SmartSep bulk media offer a perfect solution for challenging separations. With the high binding capacity and recovery, the media allow high-throughput purifications and increased productivity. Easy elution of target compounds improves the whole process. BioPro SmartSep S30 (30 µm) Recovery (> 98% Purity) Ribonuclease A Cytochrome c Lysozyme Total BioPro SmartSep S30 90.5% 81.5% 99.3% 90.7% TSKgel SP-3PW 74.2 % 54.4 % 99.5 % 76.9 % GE Source 30S 87.2 % 76.0 % 99.5 % 87.8 % TSKgel SP-3PW (Porous S type, 30 µm) up to 50% higher recovery GE Source 30S (Porous S type, 30 µm) Comparison of resolution with competitors materials. Column: 50 x 5.0 mm ID Eluent: A) 20 mm NaH 2 PO 4 -Na 2 HPO 4 (ph 6.8) B) 20 mm NaH 2 PO 4 -Na 2 HPO 4 (ph 6.8) containing 0.5 M NaCl Gradient: 0-100% B, 30 column volumes Flow rate: 1600 cm/hr (5.23 ml/min) Temperature: 25 C Detection: UV at 220 nm Injection: 20 ml (30 mg Proteins) Sample: 1. Ribonuclease A (0.5 mg/ml) 2. Cytochrome c (0.5 mg/ml) 3. Lysozyme (0.5 mg/ml) BioPro SmartSep S30 maintains its high resolution and high sample loading ability even at 1600 cm/hr and under high loading condition (30 mg/ml). It shows up to 50% higher recovery for specific target compounds compared to the competitor s materials. These features of the BioPro SmartSep material indicate the possibility of cost savings for your purification.

20 Low Backpressure BioPro SmartSep 20 µm BioPro SmartSep 30 µm BioPro 75 µm 50 x 5.0 mm ID BioPro SmartSep 20 µm BioPro SmartSep 30 µm BioPro 75 µm 350 x 15 mm ID Upper pressure limit (SmartSep 20/30 µm) Upper pressure limit for regular use (SmartSep 20/30 µm) Upper pressure limit (BioPro 75 µm) Column: 50 x 5.0 mm ID (upper graph) 350 x 15 mm ID (bottom graph) Eluent: water BioPro series media demonstrate low backpressures over a wide range of flow rates. Less than 1.0 MPa backpressure is generated at a flow rate of 2000 cm/hr with bed length of 50 mm. The pressure-flow curve is shown in the figure above. The resins with particle size of 30 µm allow high flow rates even with low pressure equipment.

Scalability across All Particle Sizes 21 BioPro SmartSep materials have the same separation characteristics across the different particle sizes. 1. Transferrin 2. Trypsin inhibitor Column: 50 x 4.6 mm ID Eluent A: 20 mm Tris-HCl (ph 8.1) Eluent B: Eluent A containing 0.5 M NaCl Gradient: 10-80% B (0-60min) Flow rate: 0.5 ml/min (180 cm/hr) Temperature: 30 C Detection: UV at 220 nm 1. Ribonuclease A 2. Cytochrom c 3. Lysozyme Column: 50 x 5.0 mm ID Eluent A: 20 mm NaH 2 PO 4 -Na 2 HPO 4 (ph 6.8) Eluent B: Eluent A containing 0.5 M NaCl Gradient: 0-100%B (0-60min) Flow rate: 0.59 ml/min (180 cm/hr) Temperature: 25 C Detection: UV at 220 nm The consistent performance across all particle sizes is advantageous for seamless method transfer between particle sizes.

Purification of Monoclonal Antibodies

Purification of Monoclonal Antibodies 23 For purification of monoclonal antibodies, high demands are required from the separating medium. Factors influencing the binding characteristics of lgg are ph, linear velocity and salt concentration (conductivity) at the time when the sample is loaded onto the column. A purification of anti-human TNF-a monoclonal antibody was performed using BioPro SmartSep and the influence of factors such as ph, linear velocity and salt concentration were studied. The BioPro SmartSep material shows good performance in all the tests. Comparison of the Performance of BioPro SmartSep and Competitors Products in the Purification of anti-human TNF-a monoclonal antibody ph 5.3 rprotein A Anti-human TNF-a monoclonal antibody Formulation of the humanized anti-human TNF-α monoclonal antibody ph 6.0 Anti-human TNF-a monoclonal antibody rprotein A Column: 50 x 5.0 mm ID Eluent: A) 20 mm citric acid-naoh (ph 5.3) B) Eluent A containing 0.5 M NaCl Gradient: 0-100% B (0-30 CV) Flow rate: 180 cm/hr (0.59 ml/min) Temperature: ambient Detection: UV at 280 nm Sample: Anti-human TNF-a monoclonal antibody (after affinity chromatography) lgg Load: 0.1 mg Injection: 0.25 ml BioPro SmartSep S30 GE Source 30S Tosoh TSKgel SP-3PW

24 Purification of Monoclonal Antibodies Influence of ph, linear velocity and salt concentration on the purification of IgG using BioPro SmartSep Experimental conditions ph: 6.0 vs. 5.3 Linear velocity: 200-800 cm/hr Salt concentration: 0-50 mm NaCl Column: Eluent: Flow rate: Temperature: Detection: Sample: 50 x 5.0 mm ID A) 20 mm citric acid-naoh buffer (ph 5.3 or 6.0) B) Eluent A containing 0.5 M NaCl 200-800 cm/hr (0.66-2.62 ml/min) ambient (25 C) UV at 280nm 1.5 mg/ml human polyclonal IgG in equilibration buffer Influence of ph ph DBC (mg/ml-resin, 10% breakthrough) ph 5.3 ph 6.0 BioPro SmartSep S30 110 103 Tosoh TSKgel SP-3PW (30 μm) 61 64 GE Source 30S (30 μm) 58 58 DBC (mg/ml-resin) 120 110 100 90 80 70 60 50 40 30 20 10 0 5 6 7 ph = BioPro SmartSep S30 = TSKgel SP-3PW (30 µm) = GE Source 30S (30 µm) High binding capacities are achieved regardless of elution of ph. Therefore, milder eluting conditions for IgG can be selected to protect the product purity.

Purification of Monoclonal Antibodies 25 Influence of salt concentration DBC (mg/ml-resin, 10% breakthrough) ph 5.3 NaCl concentration 0 mm 25 mm 50 mm Conductivity 1.36 ms/cm 4.14 ms/cm 6.8 ms/cm BioPro SmartSep S30 107 97 50 Tosoh TSKgel SP-3PW (30 μm) 64 55 27 GE Source 30S (30 μm) 58 49 19 Flow rate: 200 cm/hr (0.66 ml/min) Sample: 1.5 mg/ml human polyclonal lgg in equilibration buffer containing 0.25, 50 mm NaCl = BioPro SmartSep S30 = TSKgel SP-3PW (30 µm) = GE Source 30S (30 µm) BioPro SmartSep has a higher salt concentration tolerance. This simplifies the desalting process after Protein A chromatography and will help to shorten the production process.

26 Purification of Monoclonal Antibodies Influence of linear velocity Linear velocity DBC (mg/ml-resin, 10% breakthrough) 200 cm/hr 400 cm/hr 800 cm/hr BioPro SmartSep S30 110 93 84 Tosoh TSKgel SP-3PW (30 μm) 61 42 26 GE Source 30S (30 μm) 58 41 23 = BioPro SmartSep S30 = TSKgel SP-3PW (30 µm) = GE Source 30S (30 µm) BioPro SmartSep maintains higher binding capacity values over a wider range of linear velocities. This will increase product throughput for the purification process without any loss of efficiency.

Purification of Monoclonal Antibodies 27 Conclusions BioPro SmartSep materials meet the highest demands for the purification of monoclonal antibodies. High binding capacity is achieved regardless of elution of ph, linear velocity or salt concentration. This allows purification processes to be carried out more efficiently. Higher throughput with no loss of efficiency Simplification of desalting processes Reduced processing costs Short delivery time for industrial-scale quantities Full compliance with GMP regulations Purified monoclonal antibody lgg1

28 Screening Kits and Test Samples Screening kits and bulk samples for media selection and method development YMC offers a number of ion exchange screening kits based on 1 ml or 5 ml columns and also free bulk media samples for testing. This provides a significant advantage and efficiency in media screening and purification method development. 1 ml Type (26 x 7.0 mm ID) Resin screening Purification method development 5 ml Type (26 x 15.6 mm ID) Purification method development Loadability studies Please contact us to order your free bulk media samples for testing.

Ordering Information for BioPro Resin 29 Availability Large production capacity for YMC s IEX resin. Short delivery time even for large quantities. Full compliance with GMP requirements. Strong anion exchanger: BioPro Q Product Particle Size Code Strong cation exchanger: BioPro S Pack Sizes* 50 ml 250 ml 1 L 5 L 10 L 20 L BioPro SmartSep Q10 10 µm QSA0S10 BioPro SmartSep Q20 20 µm QSA0S20 BioPro SmartSep Q30 30 µm QSA0S30 BioPro Q75 75 µm QAA0S75 Product Particle Size Code * Larger or customised pack sizes are available on request. Pack Sizes* 50 ml 250 ml 1 L 5 L 10 L 20 L BioPro SmartSep S10 10 µm SSA0S10 BioPro SmartSep S20 20 µm SSA0S20 BioPro SmartSep S30 30 µm SSA0S30 BioPro S75 75 µm SPA0S75 Regulatory support file available under non-disclosure agreement. Used in validated cgmp-manufacturing processes. Customised material available on request. DMF registerd with FDA. Ordering Information for Preparative Screening Kits Preparative screening kits Product name* Particle Size Specification Column volume Product number BioPro Q75 75 µm 5 / pack 1 ml BPQAA0S75-01PK 5 / pack 5 ml BPQAA0S75-05PK 5 / pack 1 ml BPQSA0S30-01PK BioPro SmartSep Q30 30 µm 5 / pack 5 ml BPQSA0S30-05PK 5 / pack 1 ml BPSPA0S75-01PK BioPro S75 75 µm 5 / pack 5 ml BPSPA0S75-05PK 5 / pack 1 ml BPSSA0S30-01PK BioPro SmartSep S30 30 µm 5 / pack 5 ml BPSSA0S30-05PK * Other screening kits are available on request

30 YMC Glass Columns Ideally suited for use with BioPro Prep stationary phases: Glass columns made by YMC for biochromatography YMC ECO columns Pressure resistance: 5-30 bar Inner diameter: 10-80 mm Column length: 120-1000 mm Variable bed length Column volumes: 0-5 L Available as AB (aqueous buffer versions) SR (solvent resistant versions) YMC ECO PLUS column Pressure resistance: 30-80 bar Inner diameter: 5-50 mm Column length: 125-500 mm Variable bed length Column volumes: 0-950 ml Available as AB (aqueous buffer versions) SR (solvent resistant versions) YMC Pilot columns Inner diameter 100 mm, 140 mm and 200 mm, others on request Two standard glass lengths 500 or 850 mm, others on request Variable bed length (standard 100-400 mm or 450-750 mm) Column volumes: up to 24 L Pressure resistance: 5-10 bar Optional accessories, e.g. manometer, bubble traps, stop valves, packing devices Manufactured to customer s demands Also available as SR version = Solvent Resistant

YMC Solutions for Preparative Chromatography 31 YMC has more than 30 years experience in the manufacture of stationary phases for preparative liquid chromatography. BioPro series products are polymeric ion exchange resins for the purification of biological molecules. They represent one part of the three part YMC-Prep portfolio: silica, hybrid silica and polymer media. Further information on YMC*Gel silica and YMC-Triart Prep products can be found in the following brochures: YMC*Gel HG-series High grade silica phases for preparative HPLC The Selectivity Company YMC*Gel HG-series brochure General purpose preparative phases based on a high grade silica base. Available as silica or with C18, C8, C4, C1, phenyl, cyano, amino or diol bonding. Particle size: 10 µm, 15 µm, 20 µm or 50 µm Pore size: 12 nm, 20 nm or 30 nm (Other particle and pore sizes on request) www.ymc.de YMC-Triart Prep Hybrid silica phase, stable between ph 2.0-10.0. Available with C18 and C8 bonding. Particle size: 10 µm, 15 µm or 20 µm Pore size: 12 nm or 20 nm (Other particle and pore sizes on request) GE is a trademark of General Electric Company. Tosoh is a trademark of Tosoh Bioscience LLC.

Your local distributor: CO., LTD. YMC Karasuma-Gojo Bld. 284 Daigo-cho, Karasuma Nishiiru Gojo-dori Shimogyo-ku, Kyoto 600-8106 Japan TEL. +81(0)75-342-4515, FAX +81(0)75-342-4550 www.ymc.co.jp Europe GmbH Schöttmannshof 19 D-46539 Dinslaken Germany TEL. +49(0)2064/427-0, FAX +49(0)2064/427-222 www.ymc.de America, Inc. 941 Marcon Boulevard Suite 201 Allentown, PA18109 USA TEL. +1-610-266-8650, FAX +1-610-266-8652 www.ymcamerica.com Taiwan Co., Ltd. 1F., No. 76, Ln. 191, Sec. 3, Minquan E. Rd., Songshan Dist., Taipei City 105, Taiwan (R.O.C.) TEL. +886-2-2716-0840, FAX +886-2-2716-2090 www.ymctaiwan.com Korea Co., Ltd. 310 Woolim W-City, 9-22 Pangyo-ro 255, Beon-gil, Bundang-gu, Sungnam-si, Gyeonggi-do 13486 Korea TEL. +82-31-716-1631, FAX +82-31-716-1630 www.ymckorea.com India Pvt. Ltd. A-154-155, 1st Floor, Eros Boulevard Hotel Crown Plaza, Plot No.13-B District Centre Mayur Vihar Phase-I New Delhi-110091 India TEL. +91-11-45041601; 45041701, FAX +91-11-45041901 www.ymcindia.com Co., Ltd. Shanghai Rep. Office Far East International Plaza A2404 No. 319 Xianxia Road, Shanghai 200051 P.R. China TEL. +86-21-6235-1388, FAX +86-21-6235-1398 www.ymcchina.com Singapore Tradelinks Pte. Ltd. 29 Mayo Street #03-03, Singapore 208315 TEL. +65-9023-7617 www.ymc.sg BioPro IEX Resins 09/2017_EN_V1.3