Sour top of line corrosion testing with methanol. Gaute Svenningsen Institute for Energy Technology P.O. box 40 NO-2027 Kjeller NORWAY ABSTRACT

Similar documents
Top of Line Corrosion Testing for a Gas Field with Acetic Acid and Low CO 2

TOP OF THE LINE CORROSION IN SOUR ENVIRONMENT STUDY OF THE CONTROLLING PARAMETERS

ABSTRACT INTRODUCTION

Rolf Nyborg and Arne Dugstad Institute for Energy Technology P.O. Box 40, N-2027 Kjeller, Norway

Top-of-the-Line Corrosion in The Presence of Hydrocarbon Co-Condensation in Flowing Condition

Experimental Study of Sour Top-of-the-Line Corrosion Using a Novel Experimental Setup

Effect of Iron Sulfide Deposits on Sour Corrosion of Carbon Steel

Top of Line Corrosion and Water Condensation Rates in Wet Gas Pipelines

Localized Top of the Line Corrosion in Marginally Sour Environments

Development of Corrosion Inhibitors for Prevention of Top of the Line Corrosion (TLC)

Combined Effect of CO 2, H 2 S and Acetic Acid on Bottom of the Line Corrosion

CORROSION MITIGATION WITH ph STABILISATION IN SLIGHTLY SOUR GAS/CONDENSATE PIPELINES

ELEMENTAL SULFUR CORROSION OF CARBON STEEL IN THE PRESENCE OF SULFUR SOLVENT AND MONOETHYLENE GLYCOL

HIGH PRESSURE CO 2 CORROSION ELECTROCHEMISTRY AND THE EFFECT OF ACETIC ACID

Paper No. CORROSION CO 2 CORROSION IN THE PRESENCE OF TRACE AMOUNTS OF H 2 S

CORROSION FAILURE IN A LINED SOUR GAS PIPELINE - PART 1: CASE HISTORY OF INCIDENT. L. Simon Shell Canada Energy Pincher Creek, Alberta

Paper No Top of the Line Corrosion in H 2 S/CO 2 Environments

A Novel Method to Mitigate the Top of the Line Corrosion in Wet Gas Pipelines by Corrosion Inhibitor within a Foam Matrix

ABSTRACT INTRODUCTION

CORROSION IN ACID GAS INJECTION SYSTEMS - PROJECT 101

Black powder formation in thin water layers under stagnant conditions

CO 2 Top-of-the-Line Corrosion in Presence of Acetic Acid: A Parametric Study

KINETICS OF IRON SULFIDE AND MIXED IRON SULFIDE/CARBONATE SCALE PRECIPITATION IN CO 2 /H 2 S CORROSION

Paper No. Effect of FeCO 3 Supersaturation and Carbide Exposure on the CO 2 Corrosion Rate of Carbon Steel

Influence of Hydrogen Sulfide on CO 2 Corrosion in Pipeline Steel

Title of Innovation: CorroLogic VpCI 637 TOL. Summary Description: Nominee(s) Boris Miksic, Cortec Corporation. Category: Chemical Treatment

High-Temperature Oxidation Behavior of a New Ni-Cr-Mo-Si Alloy

Effect of Precorrosion and Temperature on the Formation Rate of Iron Carbonate Film

Effect of Operating Parameters on the Inhibition Efficacy of Decanethiol

SANICRO 29 FOR OCTG TUBE AND PIPE, SEAMLESS

Hydrogen Permeation of Pipeline Steel under Sour Condensate Film Condition

Top of the line corrosion Part 1: Review of the mechanism and laboratory experience

Yuan Song, Attila Palencsár, Gaute Svenningsen, and Jon Kvarekvål Institute for Energy Technology (IFE) P.O. Box 40 NO-2027, Kjeller Norway

Abstract. 1. Introduction

ABSTRACT INTRODUCTION

Inland Technologies Inc

Causes of Increased Corrosion in Oil and Gas Pipelines in the Middle East

Corrosion Behavior of Deep Water Oil Production Tubing Material under Supercritical CO 2 Environment: Part II. Effect of Crude Oil and Flow

A STUDY OF PROTECTIVE IRON CARBONATE SCALE FORMATION IN CO 2 CORROSION

Integrity of Corrosion Inhibitor Films in Multiphase Flow

Predict 7.1 Product Information Note

Effect of Alloying Elements on the Corrosion Behavior of Carbon Steel in CO 2 Environments

A STUDY OF FACTORS AFFECTING CO2 CORROSION AND INHIBITOR EFFECTIVENESS USING A MULTI-PHASE FLOWLOOP

Factors Influencing Materials Selection in Condensing Economizers

CORRMET LIMITED, 189 St. Georges Terrace, Level 8, Unit 2, Perth, Western Australia 6000,

ABSTRACT INTRODUCTION

Effect of Chloride on Localized Corrosion Initiation of Carbon Steel in a CO 2 Aqueous Environment Xin Gao, Bruce Brown, Srdjan Nesic

A Mechanistic Study of the Role of Pyrite in Localized Corrosion of Mild Steel

Product Test Report. PTR-3074 Swagelok Company. Rev. B Solon Road January 2015 Solon, Ohio U.S.A. Page 1 of 5

Paper No. CORROSION MODELING OF CO 2 CORROSION OF MILD STEEL AT HIGH PRESSURES OF CO 2 AND IN THE PRESENCE OF ACETIC ACID

family of stainless steels can be divided into five (5) categories:

Kinetics of Corrosion Layer Formation. Part 2 Iron Sulfi de and Mixed Iron Sulfi de/carbonate Layers in Carbon Dioxide/Hydrogen Sulfi de Corrosion

Paper No. CORROSION

Research Article Test Conditions for Pipeline Materials Selection with High Pressure Sour Gas

Soil Temperature Monitoring and Study of Geothermal Heat Pump Systems

Top-of-the-line corrosion

New alloying concepts for increased corrosion resistance of welded linepipe steels in CO 2 containing aqueous media

ROLES OF PASSIVATION AND GALVANIC EFFECTS IN LOCALIZED CO 2 CORROSION OF MILD STEEL

UNDERSTANDING OF WORK ROLL CORROSION AND OXIDATION IN A HOT STRIP MILL*

Measurements. A thesis presented to. the faculty of. In partial fulfillment. of the requirements for the degree. Master of Science.

Effect of Alloying Elements on the Corrosion Behavior of Carbon Steel in CO 2 Environments

THE EFFECT OF ACETIC ACID ON THE INTEGRITY OF PROTECTIVE IRON CARBONATE LAYERS IN CO 2 CORROSION OF MILD STEEL

SELECTION CASING MATERIAL DEPENDING OF WELLS FLUID CORROSIVITY

Results are presented in Table 1. The tube was fabricated from a Type 347 and no unusual conditions were noted.

Compatibility & Interactions between Cathodic Protection and a Vapor Phase Corrosion Inhibitor

Corrosion Resistance of Heat Exchanger Fin Materials to Potassium Hydroxide Sodium Hypochlorite-Based Cleaning Chemicals and Ammonia

Nathan A. Hatcher and Ralph H. Weiland, Optimized Gas Treating Inc., USA, discuss the fate of ammonia in refinery amine systems.

Experimental Research on Non-Condensable Gases Effects in Passive Decay Heat Removal System

SIGNIFICANCE OF HYDROGEN EVOLUTION IN CATHODIC PROTECTION OF STEEL IN SEAWATER

Ahmad Zaki B Abas Petronas Research SDN. BHD, Selangor Darul Ehsan, Malaysia ABSTRACT INTRODUCTION

Erosion corrosion of mild steel in hot caustic. Part II: The evect of acid cleaning

STUDY OF WETTABILITY OF DIFFERENT MILD STEEL SURFACES

WATER/HYDROCARBON CO-CONDENSATION AND THE INFLUENCE ON TOP-OF-THE-LINE CORROSION

Modular Oil & Gas Equipment Onshore & Offshore

De-listing Protocol for Treated Spent Iron Sponge - September 2006

CHARACTERIZATION OF CORRODED TUBING UNDER CO 2 ENVIRONMENT

Performance of Nickel-Coated Manganese Steel in High-Chloride Low-Sulphate Seawater Environments

FEASIBILITY STUDY FOR AN UNPIGGABLE SUBSEA PIPELINE A CASE STUDY OF AN OFFSHORE PIPELINE

WIRELINES and WELL-SERVICE STRANDS

Investigation into Sand Deposition and Transportation in Multiphase Pipelines

The Effect of Cl - and Acetic Acid on Localized CO 2 Corrosion in Wet Gas Flow

THE IMPACT OF THERMAL CYCLES OF SUPERHEATED STEAM ON PIPES MATERIAL OF BY-PASS STATION OF STEAM AND GAS-STEAM TURBINES

Protection Effectiveness of Vapor Corrosion Inhibitor VpCI 619 for Corrosion Under Insulation at Elevated Temperatures

FSM - DEVELOPMENTS FOR MONITORING OF STRESS CORROSION CRACKING IN STORAGE TANKS

CORROSION OF STEELS IN WATER AND HYDROGEN SULPHIDE

A new pipeline cleaning technology: Hydraulically Activated Power Pigging (HAPP TM )

MECHANISTIC MODEL FOR THE PREDICTION OF TOP-OF-THE- LINE CORROSION RISK

Aegis Tech Line Aegis Chemical Solutions Technical Newsletter Volume 09, February 2019

COCATE. Corrosion and Protection of Pipe Steels in CO 2 Transport. TNO, Bevesierweg, 1780 AM Den Helder, Netherlands b

EFFECT OF RESIDUAL STRESSES ON THE HIC RESISTANCE OF ERW PIPES FOR LINE PIPE APPLICATIONS. + Salzgitter Mannesmann Forschung GmbH ABSTRACT

A study on the Effect of Volatile Corrosion Inhibitors on Impressed Current Cathodic Protection

Standards for Evaluating Oil Field Corrosion Inhibitors in the Laboratory

Corrosion Behavior of Mild Steel in Sour Environments at Elevated Temperatures

Comparison of Grade 91 and 347H Corrosion Resistance in the Low-Temperature Components of Direct Supercritical CO2 Power Cycles

STRESS CORROSION CRACKING OF STAINLESS STEELS IN HIGH PRESSURE ALKALINE ELECTROLYSERS

ON THE EVALUATION OF PRECIPITATION HARDENING ALLOY 625 FOR USE IN THE PRODUCTION OF SOUR GAS. R. D. Mack, 0. A. Onyewuenyi, and J. W.

Titanium Tubular Technology

JOINT EUROPEAN SUMMER SCHOOL FOR FUEL CELL AND HYDROGEN TECHNOLOGY

Compatibility and Interactions Between Cathodic Protection and a Vapor Phase Corrosion Inhibitor

Effect of Solution ph on Corrosion Product Layer Formation in a Controlled Water Chemistry System

Transcription:

Paper No. 9337 Sour top of line corrosion testing with methanol Gaute Svenningsen Institute for Energy Technology P.O. box 4 NO-227 Kjeller NORWAY ABSTRACT Although relatively few failures associated with sour top of line corrosion (TLC) have been reported in field, it has been recognised as a corrosion threat, particularly if methanol is present. The toxicity and flaability of H 2 S, however, puts significant health, safety and environmental (HSE) restrictions on test equipment for sour corrosion testing, especially at high H 2 S pressures. In this work, a specially made sample holder that can be fitted inside regular autoclaves was used for simulating sour TLC in the presence of methanol. The experiments showed that for 1 bar H 2 S + 1 bar CO 2, the TLC mass loss rate was.2-.3 /y of general corrosion without localized attacks. The presence of methanol (% by weight in the bulk liquid phase) resulted in significant localized corrosion attacks with just a slight increase of the mass loss corrosion rate. Key words: Top of line corrosion, H 2 S, methanol, test equipment INTRODUCTION Top of line corrosion (TLC) has been recognized as a corrosion threat since the 198ies. 1-11 Although the first reported cases of TLC were for sour conditions (CO 2 + H 2 S), 12-14 the major focus has been on sweet TLC (CO 2 only). The number of sour TLC failures is limited compared to sweet TLC, indicating that sour TLC is a less coon problem. Consequently, sour TLC has been given relatively little attention. However, several sour TLC failures in the field have been documented, 12-28 and lately more research has been carried out on this topic. 2,8,27-4 In contrast to sweet TLC, the condensation rate is less important for sour TLC. 1 For sour TLC the steel surface temperature is important, and recent literature suggests that steel temperatures around 2-3 C are more susceptible to sour TLC than at higher temperatures. 27-29 It was assumed that this effect is related to the protectiveness of the iron sulphide, which is claimed to be better at high temperature than at low temperature. Furthermore, a recent literature review showed that methanol was present in 7 out of 1 cases of failures, suggesting that the presence of methanol can have a negative impact on sour TLC, but it is obviously not an absolute prerequisite for sour TLC to occurr. 1 217 by NACE International. NACE International, Publications Division, 183 Park Ten Place, Houston, Texas 7784. 1

The toxicity and flaability of H 2 S makes sour corrosion experiments much more difficult to carry out than sweet corrosion experiments. Particularly, flow loop TLC experiments are challenging since the amount of H 2 S (gas phase, dissolved in the liquid phase) would be large and therefore pose a serious HSE risk in case of leakage. Large quantities of H 2 S will also make disposal of the used gas/liquid more demanding. Small scale testing in autoclaves is therefore preferred, at least for screening purposes. However, flow effects cannot be realistically mimicked since the autoclave is without gas flow and only have natural convection. Various methods have been applied for sour TLC testing. Most methods involve forced cooling on a coupon paced inside a closed system (autoclave or flow loop). Cylindrical cold finger type of test coupons (Figure 1) were used in our lab (Institute for Energy Technology, IFE) earlier. 2 Although the setup was simple, the cylindrical shape made it difficult to ensure uniform condensation rate. In addition, the condensed droplets would easier fall off than on a horizontal coupon. The curved shape made the corrosion examination more difficult compared to flat coupons. Furthermore, to simulate condensation on the top of the line the coupon should face downwards. Thus it is apparent that flat coupons (facing downwards) will have several advantages with respect to uniform condensation rate and post-exposure examination. Figure 1: Cold finger coupons (left) and test-setup (right). The present paper describes a special sample holder that is used for simulating sour TLC inside conventional autoclaves. Since it is based on a simple setup, it can probably be fitted into most types of autoclaves as long as the space requirements are fulfilled. A spray nozzle facing the TLC coupon has also been used in some experiments to mimic the effect of a spray pig with and without batch inhibitor. 2 The simple setup, limited volume (less H 2 S HSE risk), and ease of operating makes it ideal for screening studies of sour TLC. The present work was aimed at studying the effect of different condensation rates and the effect of methanol on TLC under highly sour conditions (1 bar CO 2 + 1 bar H 2 S). Since the steel surface temperature is known to have an effect on sour TLC, it was kept fixed at 2 C in all experiments. The effect of different condensation rates was tested by applying different bulk temperatures. The effect of 217 by NACE International. NACE International, Publications Division, 183 Park Ten Place, Houston, Texas 7784. 2

methanol (used as a hydrate preventer in gas flow lines) was also studied by adding wt.% methanol to the bulk liquid phase. EXPERIMENTAL PROCEDURE Corrosion coupons The corrosion coupons were circular disks (2 diameter, 3 height) of carbon steel that were machined from cut-outs of a real pipeline. The steel composition is given in Table 1. The surface was machined to a surface finish corresponding to ~ 6 grit. Table 1: Steel composition (carbon steel). C Si Mn S P Cr Ni V Mo Cu Al Sn Nb.6.26 1..1.1.2.26.48.1.1.29.3.47 TLC sample holder The TLC coupon (carbon steel sample) was placed in a special sample holder of polyether ether ketone (PEEK) that exposed one side of the sample to the corrosive autoclave environment while the other (unexposed) sample side was exposed to circulating cooling liquid, as shown in Figure 2. During the experiment, the coupon was held in place by the overpressure in the autoclave. Circulation of cooling liquid was applied through a pipe-in-pipe setup, where cooling liquid inlet flow was through the inner pipe and exited through the annulus between the inner and outer pipe. Thus, only one pipe connection through the lid was needed. Deoxygenated mono ethylene glycol (MEG) was used as cooling liquid. Compressed air was previously used in a few experiments, but this gave less control of the coupon temperature. 2 Bottom of line coupon An additional corrosion coupon (same size and type as TLC coupon) was placed at the bottom of the autoclave to simulate bottom of the line (BOL) corrosion. The coupon was resting inside a PEEK holder to prevent galvanic coupling due to contact with the autoclave body. Sample surface temperature and condensation rate The TLC coupon surface temperature was controlled by varying the temperature of the cooling liquid. An empirical relationship (Figure 3 a) between the sample temperature, autoclave (bulk) temperature and cooling liquid was established specifically for this system using a thermocouple that was drilled into a test coupon. Coupon surface temperatures ranging from 4 C to autoclave temperature could easily be reached. Although not used in the present experiments, it should be noted that wet-dry cycling can easily be simulated by ramping the cooling liquid above and below the autoclave temperature. The condensation rates were measured by volumetric measurements of condensed water that was trapped in a funnel under the sample holder. The condensation area (carbon steel) was 4.9 cm², and it was assumed that condensation occurred essentially on the steel surface as PEEK has much lower thermal conductivity than steel. Measurements showed that condensation rates in the range of 1.8 g/m²s could be reached (2 8 C bulk temperature). For safety reasons, the empirical temperature and condensation measurements were carried out with only nitrogen gas in the autoclave. Thus, no H 2 S precautions were needed and the steel surface would remain uncorroded during the condensation measurements. However, it is believed that this did not significantly affect the steel surface temperature and condensation results. 217 by NACE International. NACE International, Publications Division, 183 Park Ten Place, Houston, Texas 7784. 3

Test procedure Experiments were started by placing the corrosion coupon in the sample holder, filling up the test liquid ( ml) and removing oxygen by repeated N 2 filling/evacuation cycles. When the autoclave had reached the target temperature, H 2 S gas was added multiple times to reach the desired partial pressure. Subsequently, CO 2 gas was added several times to reach the desired total pressure. The cooling pump was started after the first fill with H 2 S. When the experiment was finished, the autoclave was purged with nitrogen for several hours to remove H 2 S and CO 2. A special waste-system for sour gas and liquid was used to handle the purging gas and the test liquid. When all H 2 S had been removed the corrosion coupon was taken out, submerged in isopropanol to remove traces of water and then the coupon was dried in a hot oven (~ C). (a) (b) Figure 2: Schematic drawing of TLC test setup with autoclave and sample holder (a). Picture of sample holder with corrosion coupon and condensing water (b). Cooling liquid temp.( C) 2 2 1 1 Sample temp. = 2 C Sample temp. = 1 C Sample temp. = 4 C 1 3 3 4 4 6 6 7 7 8 8 9 Autocalve temperature ( C) Condensation rate (g/m²s). 2 4 6 8 1 Autoclave temperature ( C) (a) (b) Figure 3: Required temperature of the cooling liquid (MEG) as a function of autoclave temperature and sample temperature (a). Measured condensation rates as a function of autoclave temperature and sample temperature (b). 2. 1.8 1.6 1.4 1.2 1..8.6.4.2 2 C sample (MEG cooling) 4 C sample (MEG cooling) 1 C sample (MEG cooling) 217 by NACE International. NACE International, Publications Division, 183 Park Ten Place, Houston, Texas 7784. 4

Test conditions Three autoclave experiments with 1 bar H 2 S and 1 bar CO 2 were carried out in this work. The temperature of the corrosion coupon was fixed at 2 C for all experiments. The two first experiments tested the effect of condensation rate by applying different bulk temperature (4 vs. 8 C) while the third experiment tested the effect of methanol. A suary of the test conditions are shown in Table 2. Exp. ID TLC coupon temp. ( C) Bulk temp. # ( C) Table 2: Experimental parameters. Cond. H 2 S CO 2 NaCl Exp. Liquid phase rate time (g/m²s) (bar) (bar) (g/l) (days) T1 2 ± 1 4.79 1 1.1 14 Water +.1 g/kg NaCl T2 2 ± 1 8 1.1 1 1.1 14 Water+.1 g/kg NaCl T3 2 ± 1 8 * 1 1.1 14 wt.% water + wt.% methanol +.1 g/kg NaCl # Temperature of bulk phase (gas and liquid) inside the autoclave. * Cond. rate were not measured for wt.% methanol RESULTS The results from the corrosion testing are shown in Table 3. The TLC mass loss corrosion rate was.3 -.4 /y, and did not change much with condensation rate (i.e. bulk temperature) or with the additional presence of methanol in the bulk phase. The TLC coupons exposed only to water vapour (T1, T2) did not have any sign of localized corrosion, but the introduction of methanol (T3) caused significant pitting and localized corrosion, as shown in the 3D images in 2 1 1 2 1 1 2 1 2 1 3 4 3 1 1 2 1 2 (a) T1 TLC (low condensation rate) (b) T1 BOL (low condensation rate) 217 by NACE International. NACE International, Publications Division, 183 Park Ten Place, Houston, Texas 7784.

2 1 2 1 2 1 1 1 3 1 1 4 2 1 2 1 2 (c) T2 TLC (high condensation rate) (d) T2 BOL (high condensation rate) 2 2 1 1 1 1 2 1 1 2 1 3 4 1 2 1 1 2 (e) T3 TLC (with methanol) (f) T3 BOL (with methanol) Figure 4. More detailed 3D images of the methanol TLC coupon (T3) are shown in Figure. Localized attacks with up to 22 depth were present, particularly near the edges. In the central part, which had a corrosion morphology different from the edges, had general surface roughening corresponding to about 2-4 depth and in addition localized attacks (pits) with 4-12 depths. It is not known why this difference in corrosion morphology occurred with methanol, but it is probably somehow related to a liquid meniscus that formed on the edge of the coupon, between the coupon and the PEEK sample holder. The corrosion coupons located in the liquid bulk phase (BOL) had a general mass loss corrosion rate of.1.4 /y, and only a few shallow localized attacks. In contrast to the TLC coupon exposed to methanol, the BOL coupon had very low corrosion rate (.4 /y) and no localized corrosion. Exp. ID Sample temp. ( C) Bulk temp. # ( o C) Corr. rate (/y) Table 3: Experimental results. Max corr. Pit rate Corrosion morphology depth (/y) () TLC coupons T1-TLC 2 4.29 2.2 General (uniform) corrosion. 217 by NACE International. NACE International, Publications Division, 183 Park Ten Place, Houston, Texas 7784. 6

T2-TLC 2 8.2 2.2 General (uniform) corrosion. T3-TLC 2 8.36 22.7 Localized and general (uniform) corrosion. BOL coupons T1-BOL 4 4.38 4 1. General (uniform) and localized corrosion. T2-BOL 8 8.12 3.77 General (uniform) corrosion. T3-BOL 8 8.4 1.4 General (uniform) corrosion. # Temperature of gas and liquid phase inside the autoclave. 2 1 2 1 1 1 2 1 2 1 3 4 3 1 1 2 1 2 (a) T1 TLC (low condensation rate) (b) T1 BOL (low condensation rate) 2 1 2 1 2 1 1 1 3 1 1 4 2 1 2 1 2 (c) T2 TLC (high condensation rate) (d) T2 BOL (high condensation rate) 217 by NACE International. NACE International, Publications Division, 183 Park Ten Place, Houston, Texas 7784. 7

2 2 1 1 1 1 2 1 1 1 3 4 2 1 2 1 1 2 (e) T3 TLC (with methanol) (f) T3 BOL (with methanol) Figure 4: 3D images of exposed corrosion coupons... 4. 4. 3. 3. 1 1 2 3 4 6 7 2 4 6 8 1 2. 2. 1. 1... 1 2 3 4 6 7 12 1 14 16 2 18 2 (a) Near edge 4. 3. 3. 2. 2. 1. 1. 1 1.. 1. 1. 2. 2. 3. 1 2 3 4 6 7 8 9.. 1 2 3 4 1 11 12 (b) Centre area Figure : 3D images and height profiles of T3 TLC coupon exposed to methanol. The black arrows indicate the path of the height profile. 217 by NACE International. NACE International, Publications Division, 183 Park Ten Place, Houston, Texas 7784. 8

DISCUSSION The present results demonstrated clearly the detrimental effects of methanol on sour TLC. Methanol caused significant localized attacks, both with respect to attack depth but also with respect to attack density. The general (mass loss) corrosion was just slightly increased with methanol, but areas with increased general corrosion rate (surface roughening) were clearly visible. This is in agreement with most findings in the literature, reporting enhanced sour TLC with use of methanol. 1 Several authors reported that they suspected oxygen ingress due to insufficient deoxygenation of the injected methanol, and thus it was believed that the problem was more or less related to oxygen ingress. 18,24 The present experiments have shown that methanol can be detrimental for sour TLC pipelines even in a completely oxygen-free environment, resulting in significant localized attacks with a penetration rate much higher than the (average) mass loss rate. Therefore, it is possible that the root cause in many field cases is the methanol itself, at least if the methanol content is high. It is reasonable to believe that the combined effect of methanol and oxygen will result in an even worse condition, but efforts of removing oxygen from the methanol injection points will not remove the main problem which is methanol itself. The mechanism of enhanced corrosion due to methanol is not yet fully understood, but it was reported that iron sulphides that formed in methanol were fragile and had poor adherence. 41,42 Therefore the protectiveness of these iron sulfides is assumed to be poor, particularly for those formed at low temperatures. 43 The corrosion rate in a bulk phase with % methanol (T3 BOL) was low with little localized corrosion, while it was higher and significantly more localized for the T3 TLC coupon. High corrosion rates were reported for pure methanol with CO 2 and H 2 S, and localized corrosion was promoted for 2 7% methanol. 41 Since methanol is more volatile than water, the condensing phase will most likely have higher methanol content than the liquid bulk phase, and this is assumed to - at least partly - explain the difference in TLC and BOL corrosion in the T3 experiment. Furthermore, the T3 BOL coupon was exposed at a much higher temperature than the TLC coupon (8 C vs. 2 C) and thus it is likely that the iron sulphide that formed was different (different morphology or different type of iron sulphide) and therefore had a more protective surface film. However, no detailed investigation of the surface film was carried out. Although the present work is based on only a limited number of experiments and corrosion coupons, the trend is clear. Without methanol, the general sour TLC resulted in relatively uniform corrosion, but at a rate that probably is higher than most operators can accept. The present tests lasted only for 14 days and the corrosion rate may decline with time. Still, even with reduction of the corrosion rates in the long time perspective, the corrosion rates are in many cases too high for unmitigated operation. The additional presence of methanol resulted in localized corrosion with a penetration rate more than 1x the average corrosion rate, further confirming the need for enhanced corrosion mitigation of such pipelines. Such mitigation will have to be evaluated individually from pipeline to pipeline, but it can typically involve flow control to avoid stratified flow, use of continuous or batch corrosion inhibitor and enhanced corrosion monitoring on areas at risk. 1 217 by NACE International. NACE International, Publications Division, 183 Park Ten Place, Houston, Texas 7784. 9 1

CONCLUSIONS Sour top of line corrosion was simulated using a special made sample holder with internal cooling. The TLC rates were.2.3 /y for 1 bar H 2 S + 1 bar CO 2. With a fixed coupon temperature of 2 C the corrosion rate was just slightly affected by the condensation rate. The corrosion mode was uniform corrosion with no localized corrosion. When methanol was introduced (% by weight in the bulk liquid) the corrosion rate increased slightly to.4 /y, but significant localized corrosion occurred. The methanol-induced localized attacks were both deep (up to 22 attack depth after 14 days exposure) and very densely distributed. The present demonstrated the need for careful corrosion mitigation of pipelines exposed to sour TLC, particularly if methanol is being used. ACKNOWLEDGEMENTS This work was carried out as part of a joint industry project focusing on sour localized corrosion, funded by The Research Council of Norway (contract no. 228222), Baker Hughes, BG Group, Clariant, ConocoPhillips, ExxonMobil, Nalco Champion, Shell and Total. REFERENCES 1. G. Svenningsen, "Sour top of Line corrosion: An overview," 16th Nordic Corrosion Congress, paper no. 2 (21). 2. J. Kvarekvål, G. Svenningsen, R. Tems, V. Casanova, "Top-of-line corrosion in sour gas environments," 1th Middle East Corrosion Conference & Exhibition, paper no. 14139 (214). 3. M. Singer, D. Hinkson, Z. Zhang, H. Wang, S. Nesic, "CO2 top-of-the-line corrosion in presence of acetic acid: A parametric study," Corrosion 69, 7 (213): pp. 719-73. 4. R. Nyborg, A. Dugstad, "Top of line corrosion and water condensation rates in wet gas pipelines," CORROSION/27, paper no. 7 (Houston, TX: NACE International, 27).. G. Svenningsen, R. Nyborg, "Modeling of top of line corrosion with organic acid and glycol," CORROSION/214, paper no. 47 (Houston, TX: NACE International, 214). 6. Z. Zhang, D. Hinkson, M. Singer, H. Wang, S. Nesic, "A mechanistic model of top of the line corrosion," CORROSION/27, paper no. 76 (Houston, TX: NACE International, 27). 7. Z. Zhang, D. Hinkson, M. Singer, H. Wang, S. Nesic, "A mechanistic model of top-of-the-line corrosion," Corrosion 63, 11 (27): pp. 11-162. 8. S.L. Asher, W. Sun, R. Ojifinni, J. Pacheco, C. Li, J. Nelson, S. Ling, "Top of the line corrosion prediction in wet gas pipelines," CORROSION/212, paper no. 133 (Houston, TX: NACE International, 212). 217 by NACE International. NACE International, Publications Division, 183 Park Ten Place, Houston, Texas 7784. 1 11

9. U. Kaewpradap, M. Singer, S. Nesic, S. Punpruk, "Top of the line corrosion - Comparison of model predictions with field data," CORROSION/212, paper no. 1449 (Houston, TX: NACE International, 212). 1. K. Liao, Q. Yao, X. Wu, W. Jia, "A numerical corrosion rate prediction method for direct assessment of wet gas gathering pipelines internal corrosion," Energies, 1 (212): pp. 3892-397. 11. P.J. Teevens, K.W. Sand, P.J. Girard, "Prediction of classic and flow-induced internal pipeline top-of-the-line corrosion (TLC) mechanisms using ICPM: Model prediction confirmation and applicability in gas condensate pipeline operations " CORROSION/21, paper no. 1372 (Houston, TX: NACE International, 21). 12. R. Paillassa, M. Dieumegard, M.M. Estavoyer, "Corrosion control in the gaterhing system at Lacq sour gas field," Proceedings of the 2nd International Congress on Metallic Corrosion (1963). 13. M. Estavoyer, "Corrosion problems at Lacq sour gas field," Journal of the Institute of Petroleum 46, 439 (196). 14. L.A. Jean, "H2S corrosion in oil and gas production," Erdoel-Erdgas-Zeitschrift 89, March (1973). 1. "Pipeline investigation report p9h6 - Sour gas pipeline sending barrel rupture," T.S.B.o. Canada, 21-1-26. 16. M. Bonis, R. MacDonald, "H2S + CO2 Corrosion: Additional Learnings from Field Experience," CORROSION/21, paper no. 718 (Houston, TX: NACE International, 21). 17. M. Joosten, D. Owens, A. Hobbins, H. Sun, M. Achour, D. Lanktree, "Top-of-line corrosion A field failure," Proceedings of the EuroCorr 21 (21). 18. D.F. Ho-Chung-Qui, P. Eng, A.I. Williamson, "Corrosion experiences and inhibition practices in wet sour gas gathering systems," CORROSION/87, paper no. 46 (Houston, TX: NACE International, 1987). 19. H.J. Heinrichs, "Corrosion monitoring in East Crossfield D-1 gathering system," Materials Performance 14, 12 (197): pp. 27-39. 2. N.N. Bich, K.E. Szklarz, "Crossfield corrosion experience," CORROSION/88, paper no. 196 (Houston, TX: 1988). 21. B. D. Comeau, C.J. Marsden, "Unexpected field corrosion leads to new monitoring with revised predictive mode," Oil and Gas Journal, June (1987): pp. 4-48. 22. N. Bich, K.E. Szklarz, "Analysis of a Gas Field Corrosion Failure at Crossfield," Materials Performance 28, 7 (1989): pp. 4-49. 23. R. Nelson, M.A. Edwards, P. Kovash, "Monitoring and controlling corrosion in an aging sour gas gathering system A nine-year case history," CORROSION/27, paper no. 7668 (Houston, TX: NACE International, 27). 24. M.A. Edwards, B. Cramer, "Top of line corrosion - Diagnosis, root cause analysis and treatment," CORROSION/2, paper no. 72 (Houston, TX: NACE International, 2). 2. R.L. Martin, "Control of top-of-line corrosion in a sour gas gathering pipeline with corrosion inhibitors " CORROSION/29, paper no. 9288 (Houston, TX: NACE International, 29). 217 by NACE International. NACE International, Publications Division, 183 Park Ten Place, Houston, Texas 7784. 112

26. R.L. Martin, "Top-of-the-line corrosion inhibition in a sour gas pipeline," Materials Performance 48, 12 (29): pp. 48-2. 27. D. Pugh, S. Asher, N. Berchane, J. Cai, W.J. Sisak, J.L. Pacheco, F.C. Ibrahim, E.J. Wright, A. Dhokte, V. Sunil, D. Robson, "Top-of-line corrosion mechanism for sour wet gas pipelines," CORROSION/29, paper no. 928 (Houston, TX: NACE International, 29). 28. D. Pugh, S. Asher, N. Berchane, J. Cai, W.J. Sisak, J.L. Pacheco, F.C. Ibrahim, E.J. Wright, A. Dhokte, V. Sunil, D. Robson, "Top-of-line corrosion control in large diameter wet gas pipelines," International Petroleum Technology Conference, paper no. 13733 (IPTC: 29). 29. N. Yaakob, M. Singer, D. Young, "Top of the line corrosion behavior in highly sour environments: Effect of the gas/steel temperature," CORROSION/214, paper no. 387 (Houston, TX: NACE International, 214). 3. R.L. Martin, "Inhibition of vapor phase corrosion in gas pipelines," CORROSION/97, paper no. 337 (Houston, Texas: NACE International, 1997). 31. M. Singer, J. Al-Khamis, S. Nesic, "Experimental study of sour top-of-the-line corrosion using a novel experimental setup," Corrosion 69, 6 (213): pp. 624-638. 32. M. Singer, A. Camacho, B. Brown, S. Nesic, "Sour top-of-the-line corrosion in the presence of acetic acid," Corrosion 67, 8 (211): pp. 83-81-83-816. 33. M. Singer, "Top of the line corrosion in sour environment Study of the controlling parameters," 18th International Corrosion Congress (211). 34. M. Singer, A. Camacho, B. Brown, S. Nesic, "Sour top of the line corrosion in the presence of acetic acid," CORROSION/21, paper no. 11 (Houston, TX: NACE International, 21). 3. M. Singer, S. Nesic, J.N. Al-Khamis, "Corrosion assessment in Karan gas field development " CORROSION/212, paper no. C212-1411 (Houston, TX: NACE International, 212). 36. S.L. Asher, W. Sun, R.A. Ojifinni, S. Ling, C. Li, J.L. Pacheco, J.L. Nelson, "Top-of-line corrosion modeling in wet gas pipelines," 18th International Corrosoin Congress, paper no. 33 (211). 37. B.A. Miksic, M. Shen, A. Furman, R. Kharshan, T. Whited, "Vapor corrosion inhibitors for top-ofthe-line corrosion," Materials Performance 2, 8 (213): pp. 6-6. 38. A. Camacho, M. Singer, B. Brown, S. Nesic, "Top of the line corrosion in H2S/CO2 environment," CORROSION/28, paper no. 847 (Houston, TX: NACE International, 28). 39. C. Li, W. Sun, S. Ling, J.L. Pacheco, "Experimental study of top-of-line corrosion in slightly sour environments," CORROSION/212, paper no. 136 (Houston, TX: NACE International, 212). 4. R. Nyborg, A. Dugstad, T.G. Martin, "Top of line corrosion with high CO2 and traces of H2S," CORROSION/29, paper no. 9283 (Houston, TX: NACE International, 29). 41. D. Precoor, "A study of methanol corrosion in wet sour systems, with and without inhibition," Northern area Western conference (NACE International, 21). 217 by NACE International. NACE International, Publications Division, 183 Park Ten Place, Houston, Texas 7784. 13 12

42. R. MacDonald, L. Simon, K. Goerz, M. Girgis, "Corrosion failure in a lined sour gas pipeline - Part 2: Role of methanol in corrosion behind liner," Northern area Western conference (NACE International, 21). 43. L. Simon, R. MacDonald, K. Goerz, "Corrosion failure in a lined sour gas pipeline - Part 1: Case history of incident," Northern area Western conference (NACE International, 21). 217 by NACE International. NACE International, Publications Division, 183 Park Ten Place, Houston, Texas 7784. 13