DESIGN OF STEEL FRAMES OF DISSIPATIVE SHEAR WALLS

Similar documents
Seismic performance of ductile shear wall frame systems

DUAL STEEL FRAMES WITH RE-CENTERING CAPACITY AND REPLACEABLE STEEL SHEAR PANELS

INFLUENCE OF MEMBER COMPONENTS ON THE STRCUTURAL PERFORMANCE OF BEAM-TO-COLUMN JOINTS OF PITCHED ROOF PORTAL FRAMES WITH CLASS 3 AND 4 SECTIONS

Seismic performance of dual frames with composite CF-RHS high strength steel columns

Finite Element Analysis of Thin Steel Plate Shear Walls

STRENGTH AND DUCTILITY OF BOLTED T-STUB MACRO- COMPONENTS UNDER MONOTONIC AND CYCLIC LOADING

Experimental and numerical validation of the technical solution of a brace with pinned connections for seismic-resistant multi-story structures

SEISMIC PERFORMANCE OF MULTISTOREY STEEL FRAMES WITH STRAIN HARDENING FRICTION DAMPERS

Behavior and Characteristics of Innovative Composite Plate Shear Walls

CYCLIC PERFORMANCE OF LOW YIELD STRENGTH STEEL PANEL SHEAR WALLS

TESTS AND MODELING OF T-STUB BOLTED I-BEAM TO SHS-COLUMN FRAME CONNECTIONS

RE-CENTRING DUAL ECCENTRICALLY BRACED FRAMES WITH REMOVABLE LINKS

IMPERFECTIONS SENSITIVITY ANALYSIS OF PITCHED ROOF COLD FORMED STEEL PORTAL FRAMES

DUCTILITY OF THIN STEEL PLATE SHEAR WALLS

ASIAN JOURNAL OF CIVIL ENGINEERING (BUILDING AND HOUSING) VOL. 9, NO. 2 (2008) PAGES DUCTILITY OF THIN STEEL PLATE SHEAR WALLS

CYCLIC BEHAVIOR OF AN INNOVATIVE STEEL SHEAR WALL SYSTEM

THE STUDY OF THE OVER STRENGTH FACTOR OF STEEL PLATE SHEAR WALLS BY FINITE ELEMENT METHOD

ADVANCED NONLINEAR INVESTIGATIONS OF A 50 M SPAN FRAME CASE STUDY: THE STEEL STRUCTURE OF THE ICE RINK, CITY OF TARGU-MURES, ROMANIA

SEISMIC VULNERABILITY ASSESSMENT OF STEEL PIPE SUPPORT STRUCTURES

Comparison of Chevron and Suspended Zipper Braced Steel Frames

Seismic performance of dual steel Concentrically Braced frames

Numerical Investigations on Steel Plate Shear Walls Stiffened and Un-stiffened

A Parametric Study on the Influence of Semi-Rigid Connection Nonlinearity on Steel Special Moment Frames

EXPERIMENTAL AND ANALYTICAL STUDY ON THE BEHAVIOR OF STEEL PLATE SHEAR WALLS WITH BOX-SHAPED COLUMNS UNDER CYCLIC LOADING

Design check of BRBF system according to Eurocode 8 Use of pushover analysis

BEHAVIOUR OF BUILDING FRAMES WITH STEEL PLATE SHEAR WALLS

Research Article Research on the Behavior of the Steel Plated Shear Wall by Finite Element Method

Testing of Full-Scale Two-Story Steel Plate Shear Wall with Reduced Beam Section Connections and Composite Floors

Experimental Investigation of Light-Gauge Steel Plate Shear Walls

ANALYSIS OF STEEL PLATE SHEAR WALLS USING THE MODIFIED STRIP MODEL

EXPERIMENTAL VALIDATION OF A STRAIN HARDENING FRICTION DAMPER

Advance Design Bracing members design according to Eurocode 3

Nonlinear Behavior and Dissipated Energy of Knee Braced Frames Based on Cyclic Analysis

Effect of Geometry of Vertical Rib Plate on Cyclic Behavior of Steel Beam to Built-up Box Column Moment Connection

On Improved Performance Of Eccentrically Braced Frames With Replaceable Shear Link

FINITE ELEMENT INVESTIGATION AND DESIGN RECOMMENDATIONS FOR PERFORATED STEEL PLATE SHEAR WALLS ABSTRACT

Seismic Behavior of Composite Shear Wall Systems and Application of Smart Structures Technology

Experimental Study on the Effects of Different Concentric Bracing Configuration on Steel Frames Inelastic Behavior

Capacity Design Procedure Evaluation for Buckling Restrained Braced Frames with Incremental Dynamic Analysis

University of Alberta

ON THE BEHAVIOROF CORRUGATED STEEL SHEAR WALLS WITH AND WTHOUT OPENINGS

Analysis of RCC Building Considering the Effect of Variation in Thickness of Steel Plate Shear Wall

Influence of detailing of short links on seismic response of eccentrically braced frames

Overview of Presentation. SCBFs are Conceptually Truss Structures

Investigation of the behavior of stiffened steel plate shear walls with Finite element method

Study on Nonlinear Static Analysis of R/C Frames Retrofitted With Steel Plate Shear Wall

SEISMIC BEHAVIOR AND DESIGN OF STEEL SHEAR CONNECTIONS WITH FLOOR SLABS

Cyclic Loading Tests Of Steel Dampers Utilizing Flexure-Analogy of Deformation

FINITE ELEMENT MODELING OF ANGLE BRACING MEMBER BEHAVIOR IN EXPERIMENTALLY TESTED SUB-FRAME SPECIMENS

Hysteretic Characteristics of Braced Frames in Modular Steel Buildings

REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS

CYCLIC BEHAVIOR OF TRADITIONAL AND INNOVATIVE COMPOSITE SHEAR WALLS

EXPERIMENTAL EVALUATION OF NONLINEAR REPLACEABLE LINKS IN ECCENTRICALLY BRACED FRAMES AND MOMENT RESISTING FRAMES

A study on the stiffness effects of link beam on the behavior of coupling shear wall

Improving the Seismic Response of a Reinforced Concrete Building Using Buckling Restrained Braces

Pseudo-dynamic Testing of Self-centering Steel Plate Shear Walls

Behaviour of Steel Plate Shear Wall with Ring Cut-Outs

THE EXTENDED N2 METHOD IN SEISMIC DESIGN OF STEEL FRAMES CONSIDERING SEMI-RIGID JOINTS

IMPROVED PERFORMANCE OF BOLT-CONNECTED LINK DUE TO CYCLIC LOAD

Influence of Steel Plate Shear Wall on Multistorey Steel Building

BRACED FRAME USING ASYMMETRICAL FRICTION CONNECTIONS (AFC)

INNOVATIONS IN STEEL PLATE SHEAR WALL DESIGN

Beam-to-CFT High-Strength Joints with External Diaphragm. I: Design and Experimental Validation

Innovative Dissipative (INERD) Pin Connections for Seismic Resistant Braced Frames

Progressive Collapse Resisting Capacity of Moment Frames with Infill Steel Panels

Seismic Performance and Design of Linked Column Frame System (LCF)

The Effect of Axial Force on the Behavior of Flush End-Plate Moment Connections

Use of MSC Nastran/Patran to Study Seismic Behavior of Building Steel Shear Walls

The Effect of Frame Geometry on the Seismic Response of Self-Centering Concentrically- Braced Frames

CONSIDERATIONS ON THE DESIGN, ANALYSIS AND PERFORMANCES OF ECCENTRICALLY BRACED COMPOSITE FRAMES UNDER SEISMIC ACTION

NON-LINEAR BEHAVIOR OF STEEL PLATE SHEAR WALL WITH LARGE RECTANGULAR OPENING

EVALUATION OF SEISMIC PERFORMANCE FACTORS FOR CHEVRON BUCKLING RESTRAINED BRACED FRAMES

International Journal of Advance Engineering and Research Development A REVIEW ON PERFORMANCE BASED PLASTIC DESIGN METHODOLOGY

BUCKLING OF STEEL AND COMPOSITE STEEL AND CONCRETE COLUMNS IN CASE OF FIRE

Full-scale experimental validation of dual eccentrically braced frame with removable links. TA2 DUAREM Project

International Journal of Scientific & Engineering Research Volume 8, Issue 11, November ISSN

Numerical simulation of composite steel-concrete eccentrically braced frames (EBF) under cyclic actions

EXPERIMENTAL INVESTIGATIONS ON RESISTANCE SPOT WELDING OF BUILT-UP COLD-FORMED STEEL CORRUGATED WEB BEAMS

ANALYTICAL STUDIES OF A FULL-SCALE STEEL BUILDING SHAKEN TO COLLAPSE

INFLUENCE OF CONNECTION TYPOLOGY ON THE SEISMIC BEHAVIOUR OF MR-FRAMES

EXPERIMENTAL INVESTIGATIONS ON STEEL PLATE SHEAR WALLS USING BOX COLUMNS WITH OR WITHOUT INFILL CONCRETE

Quasi-Static Testing and Correlative Dynamic Analysis of Concentrically Braced Frames with Hollow Steel Braces and Gusset Plate Connections

An Investigation on Bracing Configuration Effects on Behavior of Diagonally Braced Frames

Experimental Evaluation of The Seismic Behavior of Steel- Braced RC Frames

Cold-formed Steel Pitched-roof Portal Frames of Back-to-back Plain Channel Sections and Bolted Joints

Response Modification Factor of Coupled Steel Shear Walls

DESIGN OF A SHEAR CONNECTOR FOR A NEW SELF-CENTERING WALL SYSTEM

composite elements, lateral loads, strain analysis, behavior Composite steel concrete elements made by steel and concrete are used in world wide almos

Full-scale Testing of the Cast Steel Yielding Brace System

AN INVESTIGATION OF SEISMIC RETROFIT OF COLUMNS IN BUILDINGS USING CONCRETE JACKET

Pal. Jour. V.16, I.3, 2017, Copyright 2017 by Palma Journal, All Rights Reserved Available online at:

Chapter 8 Commentary STEEL STRUCTURE DESIGN REQUIREMENTS

STEEL PALLET RACKS Experimental characterization of the cross- and down-aisle seismic behaviour

Hybrid-steel concrete connections under reversed cyclic loadings

Cyclic Loading Test for Reinforced Concrete Frame with Thin Steel Infill Plate

Experimental Investigation of Light-Gauge Steel Plate Shear Walls for the Seismic Retrofit of Buildings

STRUCTURAL APPLICATIONS OF A REINFORCED CONCRETE BEAM-COLUMN-SLAB CONNECTION MODEL FOR EARTHQUAKE LOADING

ALUMINIUM SHEAR-LINK FOR SEISMIC ENERGY DISSIPATION

Behaviour of single storey frames with tapered web members accounting for manufacturing and assembling imperfections

Structural Dynamics and Earthquake Engineering

Transcription:

SDSS Rio 21 STABILITY AND DUCTILITY OF STEEL STRUCTURES E. Batista, P. Vellasco, L. de Lima (Eds.) Rio de Janeiro, Brazil, September 8-1, 21 DESIGN OF STEEL FRAMES OF DISSIPATIVE SHEAR WALLS C. Neagu*, F. Dinu*, ** and D. Dubina* * The Politehnica University of Timisoara, 1 Ioan Curea, 3224 Timisoara, Romania e-mails: calin.neagu@ct.upt.ro, florea.dinu@ct.upt.ro, dan.dubina@ct.upt.ro ** Romanian Academy, Timisoara Branch, 24 Mihai Viteazul, 3223 Timisoara, Romania Keywords: Steel shear wall, Seismic design, Experimental, Monotonic, Cyclic, q factor. Abstract. This paper presents the results of an experimental program carried out on two story frame models of dissipative shear walls. Rigid and semi-rigid beam-to column joint are considered. The experimental investigation is accompanied by a numerical simulation program in order to validate and extend the conclusions of the experimental study to real multi-story frames. Values of behavior factor q obtained from experimental tests are proposed. 1 INTRODUCTION Steel plate shear walls SPSW have been used as lateral force resisting systems since 8 s, but the design specifications were rather incomplete or absent. Numerous research programs and also seismic experiences have confirmed their effectiveness. A major role on their development can be attributed to the introduction of design rules in the code provisions, e.g. AISC 25 [1]. In Europe, the application of SPSW system is limited, partly due to the lack of design provisions in seismic code EN 1998-1 [2], particularly there are no recommendations for behavior and overstrength factors q and, respectively. An additional problem refers to the prediction of the strength and stiffness capacity of the SPSW structures. Design practice requires simple models and conventional analysis software that are available and relatively simple to use. One of the models used to represent the behavior of SPSW is the strip model, developed by Thorburn et al. [3]. Thus, in order to model the steel shear walls, the steel plates are replaced by a series of truss members - strips, parallel to tension fields. A minimum of ten strips per panel are required to adequately represent the tension field action developed in the plate. In the recent years, many researchers studied the behavior of SPSW and their viability as seismic force resisting systems. Choi & Park [4] and Habashi & Alinia [5] studied experimentally the interaction between the infill panels and the boundary elements. In another experimental program, Choi & Park [6] studied the ductility and energy dissipation capacity of various SPSW typologies, and compared them with other types of bracing. In their study, Ghomi & Gholhaki [7] investigated the influence of beam-tocolumn connections on the ductility of SPSW. Based on the results of the cyclic test, Li et al. [8] proposed a capacity design principle for boundary elements. In order to address the issues presented above with regards to the performances of SPSW systems, a parametric study on different structural configurations was performed, on the aim to evaluate the demands in terms of strength and ductility [9]. Acceptance criteria and performance parameters (eg. behavior factor q) were taken according to [1]. Based on these results, an experimental program on steel plate shear wall systems has been developed at the Steel Structures Laboratory from the Politehnica University of Timisoara. The test results shown very good agreement with the parameters and acceptance criteria used in design. The paper summarizes the experimental results and gives some preliminary indications regarding the selection of behavior factor q. 41

2 EXPERIMENTAL PROGRAM 2.1 Analysis and design of steel plate shear wall structure Previous studies of the authors [9] focused on the comparative analysis of the seismic performances of conventional centric and eccentric braced systems and new systems using buckling restrained braces and dissipative Steel Plate Shear Walls. Structures were investigated using pushover analysis. The parameters that were assessed in order to evaluate the seismic performance of the structural systems were story drift and plastic deformations in dissipative members. Particular attention was paid to the potential values to be used in design of overstrength factor and to the global plastic mechanism at failure. Dual systems of SPSW have shown they are very effective both in terms of stiffness and ductility. Therefore, post-elastic behaviour of SPSW systems confirms the behavior factor q proposed in AISC 25, which is similar to that used for high dissipative moment resisting frames or eccentrically braced frames. Encouraged by the results of the numerical investigations, a test program was developed. In order to test realistic structural configurations, test specimens were extracted from a 6 story steel frame building (Figure 1.a). The 6 story structure was designed according to EN1993-1 [1], EN1998-1 and P1-1/26 [11]. The steel materials were S235 grade for infill panels and S355 grade for frame members. A 4 kn/m 2 dead load on the typical floor and 3.5kN/m 2 for the roof were considered, while the live load amounts 2.kN/m 2. Structure is located in a high seismic area, which is characterized by a design peak ground acceleration of.24g at a returning period of 1 years and soft soil conditions, with T c =1.6sec. For serviceability check, acceleration amounts.12g and allowable inter-story drift is.8 of the storey height. For collapse prevention, acceleration amounts.36g. EN1998-1 does not provide any recommendations regarding the q factor for SPSW systems. For these structural systems, AISC 25 provisions were taken as guidance. According to the later code, the behavior factor q for SPSW is similar to that of high dissipative moment resisting frames. Concluding, the design was based on a q factor equal to 6. Two-story specimens were extracted from the structure. Due to the limitations in testing capacity, the specimens were half-scale representative of the actual building (Figure 1.b). 3.5 3.5 3.5 3.5 3.5 3.5 1.75 1.75 4.8 2.4 2.4 2.4 4.8 1.4 1.4 1.4 a) b) Figure 1. Six story model used for extracting the test specimens a) and two story half-scale specimen b). 2.2 Analysis and design of half-scale models The two story specimens, extracted from the structure were half-scaled. In order to evaluate to contribution of the frame to the strength and stiffness of the structure, two types of beam-to-column connection were used. The first one is a flush end plate bolted connection and the second one is an extended end plate bolted connection. According to EC3 classification [12], flush end plate connection is semi-rigid and weak partial strength (M j, Rd =.4M b,rd ) (further refereed as semi-rigid) and extended end plate connection is rigid and strong partial strength, with a capacity almost equal to that of the connected beam (M j,rd =.9M b,rd ) (further refereed as rigid). The infill panels were bolt connected to the boundary members using fish plates. To reduce the number of bolts, an edge plate was welded to the infill panels to increase the bearing resistance. Nonlinear pushover analyses were conducted on each model in order to evaluate the behavior and the characteristic parameters, like yield strength and yield displacements, ultimate capacity and dissipation capacity. The shear walls were modeled by 1 inclined pin-ended strips, 42

oriented at angle [13]. Beams and columns were modelled with plastic hinges located at both ends. Pushover analyses have shown the ultimate capacity of structure with rigid beam-to-column connections is 1% above that of the structure with semi-rigid connections, while the stiffness is not much improved. A total of 5 specimens were designed and fabricated (see Table 1). The frames measured 35 mm high and 42 mm wide between member centerlines (Figure 2). The slenderness ratio h/t w of shear walls amounted 595 for 2 mm panels and 397 for 3 mm panels. The two actuators used for the tests have 36mm stroke and 1 kn capacity and 36mm stroke and 5 kn capacity, respectively. Table 1. Design of specimens. Specimen Infill panel Column Beam Connection Load type SR-M-T2 Semirigid Monotonic SR-C-T2 Semirigid Cyclic 2mm HEB24 R-M-T2 HEA18 Rigid Monotonic (HEB18) R-C-T2 Rigid Cyclic SR-C-T3 3mm Semirigid Cyclic HE24B HE18B HE18B HE24B HEA18 SW t=2 mm 175 HEA18 175 14 14 14 Figure 2. Typical half-scaled test specimen: designed (left) and testing set-up (right). Table 2 and Table 3 show the measured average values of yield stress f y, tensile strength f u and elongation at rupture A u. It can be observed that there are important differences between nominal and actual material characteristics. The material overstrength is larger for hot rolled sections than for plates. Thus, for hot rolled sections the maximum yield strength scattering amounts 15 N/mm 2, while for plates amounts 8 N/mm 2. The connection of the steel panels to the beams and columns used bolts. The connection was designed to develop expected shear strength of the steel panels. Extended end plate bolted connections were used for rigid beam-to-column connections while for semi-rigid ones flush end plate bolted connections. Profiles HEB24 HEB18 Table 2. Mechanical properties of rolled profiles. Nominal steel, ordered Tests Element (EN 125-2/24) f y, N/mm 2 f u, N/mm 2 A u, % S335 S355 Flange 457 69 4 Web 458 69 31 Flange 36 515 44 Web 48 54 4 Actual steel grade (supplied) HEA18 S355 Flange 419 558 32 S42 Table 3. Mechanical properties of flat steel (panels). S46 S355 43

Element Thickness, mm Nominal steel, ordered f y, N/mm 2 f u, N/mm 2 A u, % Actual steel grade Plate 2 S235 35 429 24 S275 Plate 3 S235 313 413 25 S275 All specimens were tested monotonically and cyclically using ECCS procedure [14]. According to this procedure, first a monotonic test is done in order to evaluate the force-displacement curve that is used to evaluate the yield displacement. Yield displacement D y and yield force F y are obtained by intersecting the initial stiffness y and a tangent at the curve F - D with a slope of 1% of the initial stiffness. Yield displacement D y is then used to calibrate the cyclic load history. This contains four elastic cycles (±.25D y, ±.5D y, ±.75D y and ±1.Dy), followed by groups of 3 cycles of amplitudes multiple of 2D y (3 2D y, 3 4Dd y, 3 6D y, ). Based on experimental results, the evaluation of yield displacement was adjusted to take into account the specific behavior of SPSW. Thus, the slope of initial stiffness was corrected and amounted 2% of the initial stiffness. Force, kn 1 8 6 4 2 y y /2 1 2 3 4 5 6 7 8 Normalised top displacement, D/D y 8 6 4 2-2 4 8 12 16 2 24 28 32 36 4 44 48 52 56-4 -6-8 Number of cycles, N Figure 3. ECCS cyclic loading protocol. 2.3 Experimental results 2.3.1 Monotonic tests The first test was done on the semi-rigid structure with 2mm panels SR-M-T2. The loading scheme twisted the top beam and also the left hand side column. Due to safety reasons, the test was stopped before reaching the failure of the specimen. An attempt was made to correct the problem but the frame structure was affected and therefore the test was ceased. For the R-M-T2, the out-of-plane restraint was improved and there were no impediments to conclude the test. The specimen exhibited desirable and stable behavior, as shown in Figure 4. Figure 4. Damage to the specimen R-M-T2. 44

Some local fractures were initiated at the corners of the panels at interstory drifts of approximately 2%. There were no damages of the beam-to-column connections before plastic deformations took place in panels. Local plastic deformations started to initiate at the beam flange in compression for drifts larger than 2%. The test was stopped at a top displacement of 24mm as force started to drop. The plastic rotation for the maximum capacity amounted.3rad. Results of the monotonic test were compared with the results of the pushover test. The strip model used in the pushover test did not describe accurately the behavior of the specimens. When the strip area was reduced by 1%, the accuracy of the model was very much improved (Figure 5). This reduction of the panel area conservatively reduces the strength and stiffness of the structure. The model permits the evaluation of the initial stiffness and ultimate capacity of the SPSW structure. 1 Base shear force, [kn] 8 6 4 2 Test Strip model 5 1 15 2 25 3 Top displacement, [mm] Figure 5. Comparison of experimental results for rigid specimen with 2mm thick panel and numerical results using the strip model. 2.3.2 Cyclic tests All specimens exhibited stable behavior up to cycles of 4% interstory drift. Very little pinching were recorded in the hysteresis loops for large drifts and semi-rigid specimens, only. Panels yield at approximately.6 of the story height for semi-rigid specimens and.8 of the story height for rigid specimen. Some local fractures were initiated at the corners of the panels at drifts of approximately 2%. Local plastic deformations were observed at the beam flange in compression for rigid connections. Bolted connections between infill panels and the fish plates shown small slippages but no plastic deformations either in plates or bolts. This enabled a very easy dismantling of the steel panels after the test. Associated with a small residual drift (for rigid structure), this can assure an easy intervention after a moderate earthquake to replace the damaged panels. Figure 6 plots the hysteresis of rigid and semi-rigid specimens and Figure 7 plots the envelopes of the hysteresis (results from each third cycle were considered). Contribution of rigid connections on the ultimate capacity of the specimens is larger than in the monotonic tests. As the initial stiffness is mainly attributed to the panels, differences between rigid and semi-rigid specimens in terms of stiffness are not as important as differences in terms of strength. An important objective of the experimental program was the evaluation of the behavior factor q. The q factor can be expressed as a product of the ductility factor q, that accounts for the ductility of the structure and the overstrength factor q s, that accounts for the reserve in strength of the structure (due to structural redundancy, material overstrength, member oversize due to design, other non seismic load combinations and serviceability requirements). The overstrength may vary significantly and is affected by the contribution of gravity loads, material overstrength, etc. Therefore, in order to calibrate the behavior factor q, it is more important to focus on the ductility component, which can be taken equal to the displacement ductility factor [15]. The displacement ductility factor q is therefore defined as the ratio of the ultimate displacement D u and the yield displacement D y. The parameter D u corresponds to a reduction of the load carrying capacity of 1% compared to the maximum one. The yield displacement D y can be considered the one corresponding to the modification of the elastic stiffness. Based on the 45

observation of the hysteresis curves, the ultimate displacements D u for SR-C-T2 and SR-C-T3 were corrected to take into account the slippage during the load reversal. Table 4 presents the q factor values for the specimens. Comparing these values, it may be seen the specimens have similar ductility factors q, with values ranging between 4.9 and 5.2. These values show SPSW structures have a good ductility and can provide q factors similar to those corresponding to other dissipative structure, like for example high dissipative moment resisting frames, which have ductility factors q equals to 5 (see [2]). 1 1 75 75 5 5 Base shear force, kn 25-2 -15-1 -5 5 1 15 2-25 Base shear force, kn 25-2 -15-1 -5 5 1 15 2-25 -5-5 -75-75 -1 Base shear force, kn a) b) 1 75 5 25-2 -15-1 -5 5 1 15 2-25 -5-75 -1 c) -1 Figure 6. Hysteresis curves: a) R-C-T2 specimen; b) SR-C-T2 specimen; c) SR-C-T3 specimen 1 Base shear force, kn 8 6 4 2 D y D u R-C-T2 specimen SR-C-T2 specimen SR-C-T3 specimen 5 1 15 2 Figure 7. Envelope curves of the hysteresis. 46

Table 4. q factor values for rigid and semi-rigid specimens. Structure * D y [mm] D u [mm] q q R-C-T2 32 157 4.9 4.9 SR-C-T2 23 148 (114) 6.4 4.9 SR-C-T3 23 15 (12) 6.5 5.2 Average values 5.9 5. * corrections due to slippage at the load reversal 3 CONCLUSIONS Figure 8. General view and details of the R-C-T2 specimen The paper investigated the performances of the dual SPSW structures. Due to the limitations of the testing capacity, the models were half-scaled. A total of 5 specimens were designed and fabricated, which included specimens with semi-rigid and rigid connections. Specimens were tested monotonically and cyclically. The results of the tests have confirmed the conclusions of the previous numerical studies 47

developed by the authors, on the performances of dual SPSW structures. The strip model developed by Thorburn et al. [3] was used for the preliminary analysis of the models. Based on the experimental results, this model was modified by correcting the area of the strips by a factor of.9. Rigid connections increased the yield resistance and the ultimate capacity of the structures. The initial stiffness is also improved when rigid beam-to-column connections are adopted. Behavior factor q amounts in average 5, considering the contribution of the ductility, only. These values indicate SPSW structures exhibit a dissipative behavior, similar to other dissipative structures, like for example moment resisting frames. However, further investigations are needed to calibrate the behavior factors q for SPSW structures. REFERENCES [1] AISC 341-5, Seismic provisions for structural steel buildings. American Institute for Steel Construction, 25 [2] EN 1998-1: Design provisions for earthquake resistance of structures - 1-1: General rules - Seismic actions and general requirements for structures, CEN, EN1998-1-1, October 1994. [3] Thorburn, L. J., Kulak, G. L. and Montgomery, C. J., Analysis of steel plate shear walls. Structural Engineering Rep. No. 17, Dept. of Civil Engineering, Univ. of Alberta, Edmonton, Alberta, Canada, 1983. [4] Choi, I.-R. and Park, H.-G., Steel plate shear walls with different infill plate designs. Journal of structural engineering, Vol. 135, No.7, 29. [5] Habashi, H.R. and Alinia, M.M., Characteristics of the wall frame interaction in steel plate shear walls. Journal of Constructional Steel Research, Vol. 66, Issue 2, 21. [6] Choi, I.-R. and Park, H.-G., Ductility and energy dissipation capacity of shear-dominated steel plate walls. Journal of structural engineering, Vol. 134, No. 9, 28. [7] Sabouri-Ghomi, S. and Gholhaki, M., Ductility of thin steel plate shear walls. Asian Journal of civil (Building and housing), Vol. 9, No. 2, 28. [8] Li, C.-H., Tsai, K.-C. and Lin, C.-H., Cyclic performance of full-scale two-storey narrow steel plate. Conference STESSA 29: Behavior of Steel Structures in Seismic Areas, Philadelphia, 16-2 aug. 29, CRC Press 29, Ed. F.M. Mazzolani, J.M. Ricles, R. Sause, ISBN: 978--415-56326-. [9] Dinu, F., Dubina, D. and Neagu, C., A comparative analysis of performances of high strength steel dual frames of buckling restrained braces vs. dissipative shear walls. Proc. of International Conference STESSA 29: Behaviour of Steel Structures in Seismic Areas, Philadelphia, 16-2 aug. 29, CRC Press 29, Ed. F.M. Mazzolani, J.M. Ricles, R. Sause, ISBN: 978--415-56326-. [1] EN1993-1-1: Design of Steel Structures. Part 1-1: General rules and rules for buildings, CEN, Brussels, 23. [11] P1-1/26: Cod de proiectare seismic P1: Partea I, P1-1/26: Prevederi de proiectare pentru cl diri, 26 (in Romanian). [12] EN1993-1-8: Design of Steel Structures. Part 1-8: Design of joints, CEN, Brussels, 23. [13] Driver, R. G., Kulak, G. L., Kennedy, D. J. L. and Elwi, A. E., Seismic behavior of steel plate shear walls. Structural Engineering Rep. No. 215, Dept. of Civil Engineering, Univ. of Alberta, Edmonton, Alberta, Canada, 1997. [14] ECCS, "Recommended Testing Procedures for Assessing the Behaviour of Structural Elements under Cyclic Loads". European Convention for Constructional Steelwork, Technical Committee 1, TWG 1.3 Seismic Design, No.45, 1985. [15] Newmark, N.M. and Hall, W.J., Earthquake spectra and design. Earthquake Engineering Research Institute, California, 1982. 48