C H A P T E R 3. Completing the Residential Analysis Worksheet STEP 1: WINDOWS AND OTHER GLASS AREAS

Similar documents
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION FORM 600A-01 Residential Whole Building Performance Method A CENTRAL 4 5 6

FLORIDA BUILDING CODE BUILDING

2010 Residential Energy Checklist: Additions/Alterations (Prescriptive Approach)

Home Energy Score. Learn more at homeenergyscore.gov. Uses more energy. Uses less energy Milvia Street Berkeley, CA 94704

3. Defining the Proposed and Standard Designs

Building Department Informational Handout. Residential Window Replacement Requirements

ENERGY STAR Qualified Homes National Program Requirements, Version 3.0

Chapter 1: Compliance

A. GENERAL INFORMATION

1. PREINSPECTION RESIDENTIAL ENERGY EFFICIENCY 7

Comparison Matrix of Florida Residential Building Energy Code and the International Energy Conservation Code (IECC) 2006

New Hampshire Residential Energy Code

Energy Star Qualified - New Homes

GRAYS HARBOR COUNTY TECHNICAL ASSISTANCE BULLETIN

Not useable for compliance

FLORIDA BUILDING CODE, ENERGY CONSERVATION Residential Building Thermal Envelope Approach FORM R

Final 2016 UDRH Inputs: Addendum to Massachusetts Single- Family Code Compliance/Baseline Study DOCUMENT TITLE.

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

Florida HERO Program Residential Eligible Product List All Products

If you are choosing a limited glazing area prescriptive option, completing the Glazing Schedule will be the first task.

Compliance Certificate

Plan Check & Field Inspection Guide

FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION. Florida Department of Business and Professional Regulation - Residential Performance Method

FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION. Florida Department of Business and Professional Regulation - Residential Performance Method

This Certificate of Compliance is not registered

This Certificate of Compliance is not registered

Energy Efficiency For Housing

RESIDENTIAL ENERGY CODE. The 2015 International Energy Conservation Code (IECC) as modified below.

CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01

Energy Efficiency For Housing

1. The 2018 NCECC shall regulate the design and construction of buildings for the effective use of.

Rebates for Improvements Home Efficiency Program Fort Collins Utilities

Not useable for compliance

RESIDENTIAL ENERGY EFFICIENCY

Compliance Certificate

IECC Residential Significant Changes Summary. Tier I

HERO Program Residential Eligible Product List California Residential Eligible Products... 2

SOUTHERN CALIFORNIA EDISON & SOUTHERN CALIFORNIA GAS COMPANY

Town of Farragut RESIDENTIAL CONSTRUCTION ENERGY EFFICIENCY. LAST UPDATE: July 03, 2014

2004 FLORIDA BUILDING CODE, CHAPTER 13, SUBCHAPTER 6, vs 2006 INTERNATIONAL ENERGY CONSERVATION CODE Residential Compliance Requirements

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

International Code Council

The 2009 International Residential Code and the American Recovery and Renewal Act of 2009

California HERO Program Residential Eligible Product List All Products

1 Exam Prep Florida Building Code-Energy Conservation Edition Tabs and Highlights

Oregon High Performance Home Requirements

Michigan Energy Code Training and Implementation Program

SpacePak Manual J Load Analysis Project Sheet

Guidelines for Using HOT2000 with the Performance Path of the 2010 National Building Code of Canada Subsection

Compliance Certificate

Residential New Construction Simulated Performance Alternative (SPA) Guide Updated 1/12/2019

Single Family Residence Building Permits

COMPARING THE PERFORMANCE OF A 2009 IECC CODE- COMPLIANT HOUSE USING CODE-COMPLIANT RESIDENTIAL SIMULATION PROGRAMS

FLORIDA BUILDING CODE Energy Code (Residential) 6 TH Edition (2017) Chapter 1 [RE]: Scope and Administration

Home Energy Score Report

Recommended Amendments to the

Appendix E-1f: Small Building Methodology for Pre-SB2030 Projects

2009 Washington State Energy Code/2012 International Energy Code Comparison

Supplementary Standard SB-12. Energy Efficiency For Housing

Boulder City NV Prepared by (Print Name) Signature Date

RCT Webinar-Updated 03/18/12

Energy Code Inspection Checklist

Residential Plan Review for New One and Two Family Dwellings

ERI vs. Performance Path: Which is better for the builder?

Disclaimer. August 2014 Assessing Residential Provisions in the 2015 IECC Energy Systems Laboratory

CARBON MONOXIDE ALARMS

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Please Submit Plans and Forms Electronically.

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments


Wisconsin Uniform Dwelling Code Energy Worksheet

COST EFFECTIVE ENERGY EFFICIENCY MEASURES FOR 15% ABOVE 2009 IECC CODE COMPLIANT HOUSE FOR RESIDENTIAL BUILDINGS IN TEXAS

Residential Data Collection Checklist 2009 International Energy Conservation Code Climate Zone 2

Supplementary Standard SB-12. Energy Efficiency For Housing

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

Construction Report NYSERDA Residential Performance Challenge

VALIDATION OF THE INTERNATIONAL CODE COMPLIANT CALCULATOR (IC3) v USING THE RESNET VERIFICATION PROCEDURES (NO )

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

BETA OPTION 1: PERFORMANCE RATING METHOD. Section General Information

DOE Zero Energy Ready Home National Program Requirements (Rev. 06) April 20, 2017

Building Envelope

1998 and 2000 International Energy Conservation Code Version 3.0 April 2000

CRITERIA FOR COMPUTER MODELING FOR PERFORMANCE-BASED CODE COMPLIANCE

Appendix. Home Heating Analysis Worksheet. Introduction. Directions C-1

FOR ADDITIONS and REMODELS Before filling out this application, read Green Building & Green Points Guideline Booklet for more in-depth information.

Energy Code Inspection Checklist

Consumer Energy Tax Credit

Green Points Worksheet

Energy & Cost Savings Analysis of 2009 IECC Efficiency Improvements

Italcementi Center for Research and Innovation

COMcheck Software Version Envelope Compliance Certificate

2012 IECC with Washington State Amendments

Statewide IECC Electricity Savings Report ( ), p.i. Disclaimer

Energy Compliance Information

Energy Compliance Information

City of High Point Airport Overlay District Noise Level Reduction Design Standards

Ontario s Building Code

THE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012

Recommended Amendments to the 2012 International Residential Code (IRC)

2014 British Columbia Building Code Changes

Transcription:

C H A P T E R 3 Completing the Residential Analysis Worksheet The Residential Analysis Worksheet is designed to help the reader in making the preliminary calculations necessary to complete Forms 600A-04, 600B-04 and 600C-04, although a full plans take off is not necessary for Forms 600B-04 and 600C-04. Like Form 600A-04, the Residential Analysis Worksheet take-off is performed on single units of multifamily buildings. This section will give you important information on the proper methods of computing the necessary measurements. A completed example Worksheet can be found in the Appendix to this manual. The worksheet and Form 600A-04 calculations evaluate the basic energy-using elements of the house. These elements include the building envelope (exterior glass, walls, doors, ceilings, floors and air infiltration), the heating and cooling system(s), and the water heating system. The timeconsuming part of these calculations deals with the analysis of the exterior portion of the house. Since different types of building materials (glass, concrete, wood, insulation, etc.) have varying degrees of thermal resistance, each material must be considered separately. In the Form 600A-04 calculation, multipliers specific to the type of material are used with the net areas of the component to evaluate its energy impact. For this reason, most of the worksheet is used to calculate the areas of different building components. A blank Residential Analysis Worksheet can be found on pages 28-35. If you are preparing a house for Energy Code compliance, copy the worksheet or tear it out of the manual and complete it for your house as you go over these instructions. Do not submit this worksheet to the local building department. If you wish to make the preliminary calculations using some other format, you may do so. STEP 1: WINDOWS AND OTHER GLASS AREAS Use the glass plans takeoff to organize the information you will need about the glass portions of the building envelope. Take into account all non-opaque (clear) areas including: + Windows; + Glass brick walls; + Skylights, whether glass or plastic; + French doors; + Sliding glass doors; and, + Glass area in doors (if glass area is one-third or more of the total area of the door.) 27

ORIENTA- TION RESIDENTIAL ANALYSIS WORKSHEET STEP 1: WINDOWS AND OTHER GLASS AREAS WALL TYPE (includes skylights, sliding glass doors and all windows in doors which exceed 1/3 of the door area) GLASS TYPE 1 OH OH OH WIDTH X HEIGHT = GLASS ADDI- U-factor SHGC LENGTH HEIGHT = RATIO (Rough Opening) AREA TIONS 2 AREA SUBTOTALS Glass Areas by Wall Types Description R-Value Glass Area SHGC Type A R= sq.ft. Type B R= sq.ft. Type C R= sq.ft. Type D R= sq.ft. TOTAL GLASS AREA DECIMAL EQUIVALENTS: INCHES ( ) FEET( ) 1 =.1 7 =.6 2 =.2 8 =.7 3 =.3 9 =.8 4 =.3 10 =.8 5 =.4 11 =.9 6 =.5 12 = 1.0 28 Numbers encircled with this style of shading will be used to determine multipliers on Form 600A. Numbers encircled with style of shading will be transferred directly to Form 600A. 1 or DEFAULT: Single pane clear, Single pane tint, Double pane clear, Double pane tint if window not labeled. 2 Existing glass area removed or enclosed by an addition may be subtracted from addition total

STEP 2: CONDITIONED FLOOR AREAS TABLE 1. RAISED FLOOR OVER UNCONDITIONED SPACE TYPE: INSULATION R-VALUE = FLOOR LENGTH X WIDTH = AREA SUBUNIT F1 F2 F3 F4 F5 F6 F7 F8 Subtotal FLOOR AREA SUBTOTAL TABLE 2. ADJACENT FLOORS INSULATION R-VALUE = FLOOR LENGTH X WIDTH = AREA SUBUNIT F1 F2 F3 F4 F5 F6 Subtotal FLOOR AREA SUBTOTAL 29

TABLE 3. SLAB-ON-GRADE CONDITIONED FLOOR INSULATION R-VALUE = FLOOR LENGTH X WIDTH = AREA SUBUNIT F1 F2 F3 F4 F5 F6 F7 F8 Subtotal FLOOR AREA SUBTOTAL TABLE 4. CONDITIONED FLOORS OVER CONDITIONED SPACE (2 nd or 3 rd stories) FLOOR LENGTH X WIDTH = AREA SUBUNIT F1 F2 F3 F4 Subtotal FLOOR AREA SUBTOTAL TABLE 5. TOTAL CONDITIONED FLOOR AREA FLOOR TYPE RAISED FLOOR OVER UNCONDITIONED SPACE (TABLE 1) ADJACENT FLOOR AREA (TABLE 2) SLAB-ON-GRADE CONDITIONED FLOOR AREA (TABLE 3) CONDITIONED FLOOR AREA OVER CONDITIONED SPACE (TABLE 4) FLOOR AREA SUBTOTAL SUBTOTAL 30

STEP 3: NET WALL AND DOOR AREAS TABLE 1. EXTERIOR WALLS WALL TYPE: INSULATION R-VALUE = WALL LENGTH X WIDTH = AREA W1 W2 W3 W4 W5 W6 W7 W8 W9 W10 W11 SUBTOTAL GROSS WALL AREA SUBTOTAL DOORS ON EXTERIOR WALL A TYPE AREA X NO. = AREA GLASS = NET AREA NET DOOR AREA SUBTOTAL GLASS AREA FROM STEP 1 FOR WALL TYPE A GROSS WALL NET DOOR GLASS NET WALL AREA SUBTOTAL AREA SUBTOTAL AREA = AREA DIMENSIONS 2 6 x 6 8 2 8 x 6 8 3 0 x 6 8 STANDARD DOOR SIZES ROUGH OPENING AREA 18.2 square feet 19.0 square feet 21.6 square feet 31

TABLE 2. EXTERIOR WALLS WALL TYPE: INSULATION R-VALUE = WALL LENGTH X WIDTH = AREA W1 W2 W3 SUBTOTAL GROSS WALL AREA SUBTOTAL DOORS ON EXTERIOR WALL TYPE AREA X NO. = AREA GLASS = NET AREA NET DOOR AREA SUBTOTAL GLASS AREA FROM STEP 1 GROSS WALL NET DOOR GLASS NET WALL AREA SUBTOTAL AREA SUBTOTAL AREA = AREA 32

TABLE 3. ADJACENT WALLS WALL TYPE: INSULATION R-VALUE = WALL LENGTH X WIDTH = AREA W1 W2 W3 W4 SUBTOTAL GROSS WALL AREA SUBTOTAL DOORS ON ADJACENT WALL TYPE AREA X NO. = AREA GLASS = NET AREA NET DOOR AREA SUBTOTAL GLASS AREA FROM STEP 1 GROSS WALL NET DOOR GLASS NET WALL AREA SUBTOTAL AREA SUBTOTAL AREA = AREA STEP 4. CEILING AREA TABLE 1. CEILING UNDER ATTIC (R-19 Minimum) INSULATION R-VALUE = CEILING LENGTH X WIDTH = AREA C1 C2 C3 C4 C5 Subtotal Radiant Barrier Installed IRCC Installed UNDER ATTIC TOTAL 33

TABLE 2. SINGLE ASSEMBLY CEILING (WITHOUT ATTIC) INSULATION R-VALUE = CEILING LENGTH X WIDTH = AREA C1 C2 C3 C4 C5 Subtotal SINGLE ASSEMBLY TOTAL TABLE 3. OTHER CEILINGS TYPE: INSULATION R-VALUE = CEILING LENGTH X WIDTH = AREA C1 C2 C3 Subtotal OTHER CEILINGS TOTAL STEP 5: SLAB PERIMETER SLAB-ON-GRADE WALL LENGTH SUBTOTALS FROM STEP 3 EXTERIOR WALL TYPE A EXTERIOR WALL TYPE B ADJACENT WALL TYPE C INSULATION R-VALUE = TOTAL WALL LENGTH (SLAB PERIMETER) 34

STEP 6: DUCTS, COOLING, SPACE HEATING, AND WATER HEATING DUCTS: SUPPLY RETURN DUCTS IN CONDITIONED SPACE DUCTS IN UNCONDITIONED SPACE DUCTS IN ATTIC W/RBS DUCTS IN ATTIC W/IRCC DUCTS IN ATTIC W/WHITE ROOF NONE EXISTING AHU LOCATION: GARAGE CONDITIONED SPACE BUILDING EXTERIOR ATTIC COOLING SYSTEM: CENTRAL, SEER/EER = PTAC OR ROOM UNIT, EER = HEAT PUMP, gas, COP = NONE EXISTING SIZING CALCULATION: CALCULATED SENSIBLE COOLING CAPACITY X 1.20 = BUT/H ALLOWED = TONS 12000 COOLING CREDIT: CEILING FANS MULTIZONE CROSS VENTILATION WHOLE HOUSE FAN PROGRAMMABLE THERMOSTAT NONE HEATING SYSTEM: ELECTRIC STRIP HEAT PUMP, ELECTRIC, HSPF = NONE EXISTING PTHP OR ROOM UNIT, COP = COMBINATION GAS/WATER HEATING COMBUSTION FURNACE, HSPF = OTHER HEATING PROGRAMMABLE THERM. MULTIZONE NATURAL GAS, AFUE = CREDIT: LP GAS, AFUE = NONE WATER HEATING: NUMBER OF BEDROOMS: EXISTING SOLAR WITH TANK, EF= DED. HEAT PUMP WITH THANK, EF- ELECTRIC, EF= NATURAL GAS, EF = LP GAS, EF = GAS TANKLESS WATER HEATER, EF= WATER HEATING CREDIT: HEAT RECOVERY UNIT, W/AC SOLAR, no tank, EF= HEAT RECOVERY UNIT, W/HEAT PUMP DED. HP, no tank, EF= NONE 35

The Code classifies glass areas by four factors: 1. Orientation - which compass point the window faces; 2. Wall type - the material of the wall in which the window is installed (example, frame, concrete block, etc.) 3. Type of glazing U-factor and SHGC or default (worst case) single-pane clear, singlepane tint, double-pane clear, or double-pane tint; and, 4. Either the overhang ratio or overhang length - indicators of the amount of shading from a permanent overhang. Add the areas of windows with identical features together and treat them as a group. For instance, treat all north-facing, single-pane, clear windows with a 0.18 overhang ratio (overhang length divided by overhang height) as a group. However, do not group windows with different orientations, glass type, or overhang ratio with these windows. Since this will require you to make several concurrent decisions about the glass, read through all of Step 1 before attempting the grouping. If the glass area in a door is less than one-third of that specific door area, calculate the entire door as opaque (wood or metal) under Step 3. If the glass area is one-third or more of the total door area, either calculate the entire door as glass, or calculate the glass area separately from the door area. In the latter case, include the glass square footage with the glass calculation, and the opaque square footage with the door calculation (see Step 3). Orientation Using the house plans, begin with one orientation, for example, north-facing windows (N). List the information for each window on the Step 1 table of the worksheet. Choose the window orientation from one of the eight compass direction options: N, NE, E, SE, etc. For skylights and other non-vertical roof glass use the orientation designation "H" (horizontal). Group together all the windows with the same orientation, glass type and overhang height and overhang length. Wall Type At the bottom of the table is a box for identifying the wall types, GLASS AREAS BY WALL TYPES. Write in the DESCRIPTION column the wall construction type (wood frame, CBS, etc.) and insulation level (R-VALUE) for each type. Use the letters "A", "B", etc. to identify like walls in the WALL TYPE column on the Step 1 table. GLASS AREAS BY WALL TYPES DESCRIPTION R-VALUE GLASS AREA TYPE A: Masonry Block R= 3 248.9 sq. ft. TYPE B: Frame Ext. R= 11 0 sq. ft. TYPE C: Frame Adj. R= 11 0 sq. ft. TYPE D: R= sq. ft. 36

Glass Type In most houses the glass type is the same throughout the house, with the possible exceptions of sliding glass doors and skylights. Glass is rated by an U-factor, and a Solar Heat Gain Coefficient. The U-factor and the SHGC may be found on windows that have been tested and labeled according to National Fenestration Rating Council (NFRC) procedures. However, if labeled windows will not be installed, you may use DEFAULT glass types: single- or double-pane, and clear or tinted. DEFAULT glazing values are for a worst case window and will not accurately reflect the energy use of the windows installed. Any window tint, or film, either manufactured or applied, qualifies as "TINT." Only the exterior glazing needs to be tinted in double-paned glass. Solar screens qualify as "TINT" for purposes of code calculation. ORIENTATION WALL TYPE GLASS TYPE OVERHANG LENGTH North A Single Tint 2.0 2.0 2.0 10.0 10.0 East 2.0 Enter in the GLASS TYPE column the U-factor and SHGC for each glass area. If not using labeled windows, enter whether the glazing will be single or double pane and clear or tinted glass. Overhang The Code gives you the option of evaluating the effects of window overhangs either by the OVERHANG LENGTH alone or by the OVERHANG RATIO. Figure 2. Overhang Lengths and Heights 37 The OVERHANG LENGTH (L) of a window is the horizontal measure of how far the overhang projects out from the glass surface. The OVERHANG HEIGHT (H) is the vertical measure of the distance from the bottom of the glass to the bottom of the overhang.

Overhang Length Method. This method is easier to calculate than the Overhang Ratio Method, but is less accurate. You may use this method only for windows with an overhang height no greater than 8 feet. You must use the Overhang Ratio Method for all windows which extend below 8 feet. To calculate by overhang length, complete the OVERHANG LENGTH column only. You do not need to complete the columns labeled OVERHANG HEIGHT or OVERHANG RATIO. This short cut will save you time. If you use this method and later find your calculation does not meet the Code requirements, you may recalculate using the Overhang Ratio Method. Overhang Ratio Method. The Overhang Ratio is calculated by dividing the OVERHANG LENGTH by the OVERHANG HEIGHT (Fig. 3). Windows with the same overhang length and height will have the same OVERHANG RATIO. OVERHANG LENGTH OVERHANG RATIO = OVERHANG = HEIGHT H = 5.0' 3.0 feet 5.0 feet =.6 L = 3.0' Figure 3. Calculating Overhang Ratios Enter on the worksheet the Overhang Length and Overhang Height for each window. Divide the Overhang Length by Overhang Height. Enter the Overhang Ratio on the worksheet. H Measure overhang height at highest point of the eave above the window. A window on a gable end wall is a special case. Measure the overhang length as usual. However, measure the overhang height from the bottom of the window to the bottom of the overhang at its highest point directly above the window. See Figure 4. Figure 4. Overhang Measurements for Uneven Overhangs The Code does not consider non-permanent shading devices such as canvas awnings as overhangs. For other qualifying shading devices such as slotted overhangs, louvered 38

shading devices, or Bahama shutters see Chapter 5, "Special Cases: Overhangs". If the overhangs do not meet the above conditions, the overhang length and ratio is 0. Glass Area Record the WIDTH and HEIGHT of the rough opening for each window and multiply to obtain the GLASS AREA. SAMPLE WORKSHEET (See pages 90-97 for an example of a completed worksheet.) ORIENTA- TION WALL TYPE GLASS TYPE 1 U-factor SHGC OH OH OH LENGTH HEIGHT = RATIO WIDTH X HEIGHT (Rough Opening) = GLASS AREA ADDI- TIONS 2 AREA SUBTOTALS North A Dbl Clr 2.0 3.5 0.57 4.0 3.0 12.0 N th 2.0 3.5 0.57 4.0 3.0 12.0 2.0 3.5 0.57 4.0 3.0 12.0 36.0 sq ft 10.0 7.2 1.39 8.0 6.7 53.6 53.6 sq ft 10.0 3.5 2.86 3.7 3.0 11.1 11.1 sq ft East 2.0 3.5 0.57 4.0 3.0 12.0 2.0 3.5 0.57 4.0 3.0 12.0 24.0 sq ft 2.0 4.5 0.44 6.0 4.0 24.0 24.0 sq ft South 2.0 4.5 0.44 6.0 4.0 24.0 24.0 sq ft West 2.0 3.5 0.57 2.0 3.0 6.0 As you work, circle any areas which are glass panels located in doors. You will use this information later when calculating net door areas. Glass Area Subtotals When you have listed all the windows and glass areas, check to be sure you have grouped together the windows with the same orientation, glass type, and overhang ratio or overhang length. Sum the areas for each group and enter the area under the column marked AREA SUBTOTALS. Glass in an existing building that is enclosed by an addition may be subtracted from the total glass for that orientation of the addition. Sum all the subtotals and enter the total in the box labeled TOTAL GLASS AREA. 39

Glass Areas by Wall Types In the lower left corner of the Step 1 worksheet is the GLASS AREAS BY WALL TYPE box. Using the information in the WALL TYPE and GLASS AREA columns in the above table, total the amount of glass in each type of wall. You will use this information later to calculate net wall areas. STEP 2: CONDITIONED FLOOR AREAS Step 2 helps you organize the information you will need to calculate the conditioned floor area of the house. You will need to group conditioned floor areas into the following types: 1. Raised floors over unconditioned space; 2. Adjacent floors; 3. Slab-on-grade floor; and, 4. Floor areas over conditioned space (upper floors). Calculate each group separately. To find the conditioned area for each floor type, divide the floor plan into rectangles. Make sure each rectangle includes only one type of floor and insulation level. Using the exterior dimensions from the house plans, find the length and width of each rectangle. Figure 5. Calculating Conditioned Floor Area 40

Enter the dimensions on the table for the specific floor type. Multiply the length times the width of each rectangle to find the area of each rectangle. Add the areas of the rectangles together to find the FLOOR AREA SUBTOTAL for each type of floor. If part of the house has a sloped ceiling, calculate the floor area for that part of the house separately from the non-sloped ceiling part of the house. You will find this information helpful later when calculating the ceiling areas. Table 1: Raised Floors over Unconditioned Space Calculate the area of RAISED FLOORS on Table 1 of Step 2. A raised floor over unconditioned space is one which separates conditioned space from unconditioned space. Floors over a crawl space or raised on piers are examples of this type of floor (Fig. 6.) You will need to separate this category by type (wood or concrete) and by insulation level. The Code distinguishes between wood floors of the following types of construction: + Post or pier with under floor insulation; + Stem walls with under floor insulation; and, + Stem walls with stem wall insulation. Treat each group separately. Figure 6. Raised Wood Floor Types To qualify as "stem wall" construction, there must be a continuous stem wall around the perimeter of the enclosed crawl space. See Section 605.1.A.1 for crawl space ventilation requirements. 41

Table 2: Adjacent Floors Calculate the areas of ADJACENT FLOORS in Table 2. Adjacent floors separate conditioned space from unconditioned but enclosed space. A second story floor separating conditioned space from a garage is an example of this type of construction. See Figure 7. Table 3: Slab-on-Grade Conditioned Floor Calculate the SLAB-ON-GRADE CONDITIONED FLOOR areas on Table 3 of Step 2. A slab-on-grade floor separates conditioned space from the ground. See Figure 7. Table 4: Conditioned Floors over Conditioned Space Calculate CONDITIONED FLOORS OVER CONDITIONED SPACE on the fourth table. These areas include second story floors and any other floors over conditioned spaces. See Figure 7. Table 5: Total Conditioned Floor Area On Table 5, enter all the area SUBTOTALS from Tables 1 through 4. Add the SUBTOTALS to obtain the TOTAL CONDITIONED FLOOR AREA. Figure 7. Conditioned Floor Types 42