LV bolted straight joint connector BSLB-4/16, BSLU-4/16

Similar documents
Energy Division Insulators

Rayfit The advanced heat-shrinkable joint sleeve for medium voltage joints up to 36 kv NEW ENERGY DIVISION

SPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS

PART 4 ORANGE SECTION

CS-21 STREET STRUCTURES TABLE OF CONTENTS

Connectors. Multi-purpose connecting clamps. Stainless steel cross connectors

new AIRSTOP Weather Seals LV JUICE FREE BAG OF JAFFAS ADVANTAGES October 2016 This Month When you spend over $300 (excl GST) on one invoice this month

NPS/002/001 Technical Specification for Earthing Materials

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Index GROUNDING CONNECTORS. TYPE WB Ground Rod Clamps. TYPE G/SRC Ground Rod Clamps. Heavy-Duty Clamps. Standard-Duty Clamps (Universal)

COPPER CABLES AND CONNECTORS (PTY) LTD.

Suspension clamps. Contents. General Oscillating and trunnion type suspension clamps forged.. 3. Oscillating type suspension clamps cast...

RESIN FILLING TYPE JOINTING KITS FOR LOW VOLTAGE UNDERGROUND CABLES

Technical Specification for Live Line Tap Connectors

Accessories / Screwlocks

New designed XLPE-insulated cables substituting paper-insulated pipe type cables

26/35kV Copper XLPE Insulation Electric Cable

REA LISTED. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application

A designer knows he has achieved perfection not when there is nothing left to add, but when there is nothing left to take away.

Technical Specification for Helical Fittings for Overhead Power Lines

MSME Testing Centre, 65/1, G. S. T. Road, Guindy, Chennai, Tamil Nadu. Discipline Electrical Testing Issue Date

STANDARD COAXIAL CONNECTORS

3M Eurosocket Type C (Rows A & C, A & B or A, B & C Filled)

Blue-Tip SCREW-BOLT. Ratchet teeth locks head against fixture. Reverse parabolic threads privide high load capacity

Technical Specification for Low Voltage Aerial Bundled HDPE Insulated Cables

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Fixings, bonds and clamps

F4P lay-in lugs SERIES SPECIFICATION

CABLE TERMINALS CABLE TERMINALS

Comparison of BS 5308, PAS 5308 and BS EN

CONSULTATIONS TECHNICAL GUIDELINE. HVDC extruded cable

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Series 970 PowerTrip Connectors and Accessories Contacts and Tools

Standard Bourdon tube pressure gauges EN 837-1

HS h e n EU omplia t 2002 / 9 5 / C

SENG H SENG UA UA I T N I DUSTRIE DUSTRIE PT PT E L TD w w w.se .se gh gh at u.c at om

Bolted Connectors & Terminals

Linings for drive sheaves

Linings for drive sheaves

Kenya Power and Lighting Company VI Contract A31

660 Volts 630 & 800AMP

Technical Specification for LV ABC Fuse Switch Disconnectors

Linings for drive sheaves

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

Title Cables for Railway Signalling Applications - Traction Return Bonding and Track Connection Cables

NYULMC AMBULATORY CARE CENTER FIT-OUT PHASE 1 Perkins & Will Architects PC 222 E 41st ST, NYC Project: Issued for GMP March 15, 2017

APDRP SCHEME, WESCO. Technical Specification for 33KV Air Break Switch PART 1: SCOPE AND CONDITIONS

User Manual. IWB Internally Wired Bar. Version 12/10.

Connector Selection Guide

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

Cable accessories for shipbuilding and off-shore units

7Terminals and Splices

Hollo-Bolt. Hollo-Bolt by Lindapter. Hollo-Bolt Options

Amphenol Fast Connector

SIS Solid Insulation System

Installation instructions. LORO-ATTIKASTAR siphonic drains

Glycerine filled Bourdon tube pressure gauges EN 837-1

3M Eurosocket Type C (Rows A & C, A & B or A, B & C Filled)

New Product Flyer Introduction

SMB. Aliner Industries, Inc. No. 32, Lane 387, Min-an Rd., Sinjhuang City, Taipei County 24256, Taiwan

Wire and Cable Heat-shrink Tubing Non-shrink Tubing Braided Sleeving Screening Braids Moulded Parts Terminals and Splices Wire and Cable Markers

Engineered Parts Your Design Our Competence

31-SDMS-03 REV. 01 SPECIFICATIONS FOR

MC -SEALconTACT. Multilam contacts. Multilam Technology

INSTALLATION INSTRUCTIONS AS 2.1 CORRUGATED ETERNIT ROOF

40/69 kv to 127/220 kv XLPE

DUBO retaining rings for socket head screws. DUBO toothed collar rings. KORREX protective caps for socket head screws. KORREX insulating bushes type I

May10 Rev A

1. All Members of Power Cables Sectional Committee, ET 09; 2. All Members of Electrotechnical Division Council; and 3. All other Interested.

Telecom/ Datacom Tools

SECTION PARK NON-SEGREGATED BUS SPECIFICATION

The Carbide Burr Collection.

Part levellers. Materials Steel Aluminium Copper Brass Special alloys Bimetallic

A. Division 01: Administrative, procedural, and temporary work requirements apply to this section.

EI INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV

Will accommodate up to 35 conductors while maintaining separation required to withstand instrumentation voltages

56-SDMS-01 REV. 01 SPECIFICATIONS FOR

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008

Surge arrester 3EB1. with polymeric composite housing for operating aboard traction units

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

Single core conductor BETAtherm 145

Will accommodate up to 35 conductors while maintaining separation required to withstand instrumentation voltages

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE

ALUMAX. High Amperage Power Solutions

TEMPORARY PROTECTIVE GROUNDING EQUIPMENT

(Condensed from National Electric Code)

SENTRAN. Low Profile Load Cell. For more information call

Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath

NPS/001/024 Technical Specification for Low Voltage Aerial Bundled Conductor Fittings

M7100 Pressure Transducer

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

E-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB

POWERTECH LABS INC. CONNECTABILITY TESTING OF COPPER AND ALUMINUM WIRING, PHASE 2: Current Cycling Tests Mechanical Connectors PROJECT PL-00236

Technical Specification for Insulated Low Voltage Single Core Copper Cable

SECTION ENCLOSED BUS ASSEMBLIES

NPS/002/023 Technical Specification for 132kV Power Cables.

Transcription:

BSLB-4/16, BSLU-4/16 These bolted connectors are designed for use in low voltage underground joints.. A brass body; its inner surface grooved at the manufacturing stage provides excellent electrical contact.. 2 steel bolts.. Need a unique and standard tool: wrench with socket for 2.5 mm A/F inner hexagon to tighten the bolts.. Connection copper cable. Connector body made from brass, bolts from steel.. Suitable for solid or copper conductors. sizes: 4 to 16 mm² copper BSLB-4/16 BSLU-4/16 Cu round Cu round solid cross section mm² 4-16 4-16 diameter mm Ø 2,4 Ø 5,0 Ø 2,2 Ø 4,6 SIM215 Energy PDF Feb 2012

BSLB-10/50, BSLU-10/50 These shear bolt connectors are designed for use in low voltage underground joints.. A tin plated aluminium alloy body; its inner surface grooved at the manufacturing stage provides excellent electrical contact.. 2 aluminium alloy bolts with a shear head in order to control the optimum tightening torque.. Need a unique and standard tool: wrench with 10 mm A/F socket to tighten the bolts.. Connection on aluminium or copper cable. All components made from aluminium alloy. Lubricated with special grease and wax. Suitable for solid or, round or sectorial, aluminium or copper conductors. sizes: 10 to 50 mm² aluminium and copper BSLB-10/50 BSLU-10/50 cross section mm² diameter mm Al Round Round solid solid Round Cu Round solid solid 10-50 10-50 10-50 10-50 10-50 10-50 10-50 10-50 Ø3,6 Ø8,6 Ø3,4 Ø7,8 - - Ø3,6 Ø8,6 Ø3,4 Ø7,8 - - SIM0216 Energy PDF Feb 2012

BSLB-35/95, BSLU-35/95 These shear bolt connectors are designed for use in low voltage underground joints.. A tin plated aluminium alloy body; its inner surface grooved at the manufacturing stage provides excellent electrical contact.. 2 aluminium alloy bolts with a shear head in order to control the optimum tightening torque.. Need a unique and standard tool: wrench with 10 mm A/F socket to tighten the bolts.. Connection on aluminium or copper cable. All components made from aluminium alloy. Lubricated with special grease and wax. Suitable for solid or, round or sectorial, aluminium or copper conductors. sizes: 35 to 95 mm² aluminium and copper BSLB-35/95 BSLU-35/95 cross section mm² diameter mm Al Round Round solid Solid Cu Round Round solid solid 35-95 35-95 35-95 35-95 25-95 35-95 35-95 35-95 Ø6,6 Ø12 Ø6,1 Ø11 - - Ø5,6 Ø12,9 Ø6,1 Ø11 - - SIM0217 Energy PDF Feb 2012

LV Bolted Straight joint connector BSLU-25/150-S, BSLB-25/150-S, BSLU-25/150-SU, BSLB-25/150-SU Application: Designed for use in underground joints up to 1 kv Description: The connector is made of: An aluminium alloy body tin plated or natural finish. Its inner surface grooved at the manufacturing stage provides good electrical contact with wires to be joined. 2 aluminium alloy clamping bolts with a shear head in order to control the nominal optimum tightening torque. With (BSLB) or without (BSLU) a central barrier to allow connection between plastic and paper cables. Features and benefits: FEATURES sizes: 25 to 150 mm² sectorial aluminium or copper conductors Material: body: high strength tin plated or natural Al-alloy bolts: high strength tin plated brass with special treatment Solid moisture block barrier (BSLB type) Equipped with: Shear bolts Reduced shear off torque Comply with DIN VDE 0220 part 1 BENEFITS Range taking Good electrical performance Connection on aluminium or copper cable Allow connection between paper and XLPE cable No special tool required Reliable 2 shear point bolts Reduced stand proud of the bolts after shear off http://energy.tycoelectronics.com All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, Bowthorpe EMP, Critchley, Dorman Smith, Dulmison, Hellstern, La Prairie, Morlynn, Raychem, SIMEL and SUCOFIT are trademarks. Tyco Electronics SIMEL S.A.S. Energy Division Route de Saulon F-21220 Gevrey-Chambertin Tel. (033) 3.80.58.32.00 Fax (033) 3.80.34.10.15

LV Bolted Straight joint connector BSLU-25/150-S, BSLB-25/150-S, BSLU-25/150-SU, BSLB-25/150-SU Characteristics: Description Pn RPN Cross Section mm² Type Finish PPQ BSLU-25/150-S 0-1201224-7 D72324-000 25-150 sectorial Unblocked Tinned 1 130 BSLB-25/150-S 2-1201549-6 F04358-000 25-150 sectorial Blocked Tinned 1 135 BSLU-25/150-SU 2-1201221-0 948152-000 25-150 sectorial Unblocked Natural 1 130 BSLB-25/150-SU 2-1201549-0 E89808-000 25-150 sectorial Blocked Natural 1 135 Weight (g) Application - Diameter range table: Querschnittsbereich crosssection mm² RM ROUND STRANDED RE ROUND SOLID AL SM SECTOR STRANDED SE SECTOR SOLID CU SM SECTOR STRANDED 25-95 25-95 25-150 25-150 25-150 diameter Leiterdurchmesser mm Ø 5.7 - Ø 12.5 Ø 5.5 - Ø 11 - - - http://energy.tycoelectronics.com All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, Bowthorpe EMP, Critchley, Dorman Smith, Dulmison, Hellstern, La Prairie, Morlynn, Raychem, SIMEL and SUCOFIT are trademarks. Tyco Electronics SIMEL S.A.S. Energy Division Route de Saulon F-21220 Gevrey-Chambertin Tel. (033) 3.80.58.32.00 Fax (033) 3.80.34.10.15 Ref : MH164 Rev1 05-12-2006

BSLB-95/240, BSLU-95/240 These shear bolt connectors are designed for use in low voltage underground joints.. A tin plated aluminium alloy body; its inner surface grooved at the manufacturing stage provides excellent electrical contact.. 4 aluminium alloy bolts with a shear head in order to control the optimum tightening torque.. Need a unique and standard tool: wrench with 10 mm A/F socket to tighten the bolts.. Connection on aluminium or copper cable. All components made from aluminium alloy. Lubricated with special grease and wax. Suitable for solid or, round or sectorial, aluminium or copper conductors. sizes: 95 to 240 mm² aluminium and copper BSLB-95/240 BSLU-95/240 Round AL Round Solid Solid Round CU Cross-section Diameter 95-240 95-240 95-240 95-240 70-240 95-240 Ø 11 Ø 20 Ø 10.5 Ø 18 - - Ø 9,3 Ø 20 - SIM214 Energy PDF Feb 2012