UL Evaluation Report UL ER Issued: July 25, UL Category Code: ULFB. CSI MasterFormat

Similar documents
DESCRIPTION: JM TPO Single Ply Roof Systems

UL Evaluation Report UL ER Issued: June 29, 2015 Revised: July 29, UL Category Code: ULFB. CSI MasterFormat

JM PVC Fleece Backed 50 mil, JM PVC Fleece Backed 60 mil, JM PVC Fleece Backed 80 mil

Section Property Standard Year Wind FM Physical Properties ASTM D

UL Evaluation Report UL ER Issued: December 19, 2014 Revised: August 14, UL Category Code: ULFB. CSI MasterFormat

DESCRIPTION: JM PVC Single Ply Roof Systems

Sub-level 2: Modified Bituminous Membrane Roofing Sub-level 3: Styrene-Butadiene-Styrene Modified bituminous Sheet Roofing

UL Evaluation Report UL ER Issued: December 9, Revised: September 29, UL Category Code: ULFB. CSI MasterFormat

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT (203)

Exterior Research & Design, L.L.C. Building Science and Envelope Consultants

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT (203)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years.

NEMO etc. Certificate of Authorization # Christian Street, Unit #13 Oxford, CT (203)

ICC-ES Evaluation Report. ESR-3297 Reissued March 1, 2013 This report is subject to renewal May 1, 2014.

EMPIRE SHAKE, EMPIRE PLUS SHAKE, AND EMPIRE SLATE POLYOLEFIN COMPOSITE TILES

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT (203)

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT PHONE: (203) FAX: (203)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: POLYVINYL CHLORIDE ROOFING REPORT HOLDER: IB ROOF SYSTEMS

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT PHONE: (203) FAX: (203)

REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC 250 WEST 96 TH STREET INDIANAPOLIS, INDIANA EVALUATION SUBJECT:

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT (203)

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street, Unit 13 Oxford, CT (203)

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT PHONE: (203) FAX: (203)

Exterior Research & Design, L.L.C. Building Science and Envelope Consultants

EVALUATION REPORT Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Engineering Services Program

REPORT HOLDER: CARLISLE SYNTEC POST OFFICE BOX 7000 CARLISLE, PENNSYLVANIA EVALUATION SUBJECT:

Sure-Weld (TPO) Adhered Roofing Systems Code Approval Guide January, Table of Contents

CREEK Technical Services, LLC

Code Approval Guide January, 2017

NEMO etc. Certificate of Authorization # Christian Street, Unit #13 Oxford, CT (203)

NEMO etc. Certificate of Authorization # Christian Street, Unit #13 Oxford, CT (203)

UL Evaluation Report UL ER Issued: May 31, Revised: June 6, UL Category Code: ULEZ. CSI MasterFormat

Application Instructions and Code Approvals

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (RAS)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

PRODUCT CONTROL SECTION

EVALUATION REPORT Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # CHRISTIAN STREET, UNIT 13 OXFORD, CT (203)

1. SUBJECT: DURO-LAST, DURO-TUFF, DURO-FLEECE, and DURO-FLEECE PLUS ROOFING MEMBRANES

EVALUATION REPORT ICP Adhesives and Sealants, Inc NW 44 th Street Coral Springs, FL 33065

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

PRODUCT CONTROL SECTION

Mechanical Attachment of Separation Panels Hot Asphalt Attachment of Separation Panels

PRODUCT CONTROL SECTION

C. Applicable building codes should always be checked prior to proposing the application to Mule-Hide or the building owner.


DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMOPLASTIC MEMBRANE ROOFING SECTION: POLYVINYL-CHLORIDE ROOFING

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER: POLYGLASS USA, INC.

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

PRODUCT CONTROL SECTION

DESCRIPTION: Firestone SBS and APP Modified Bitumen Roof Systems

UL Listing: EPDM Roofing Systems

PRODUCT CONTROL SECTION

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ETHYLENE PROPYLENE DIENE MONOMER ROOFING REPORT HOLDER:

Adhesive Pull Test Standard Testing Procedures

FOAMULAR Commercial Roofing

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

CREEK Technical Services, LLC

Thermoplastic Single Ply & Multi-Ply Roofing Systems

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

CREEK Technical Services, LLC


Laboratory Report T R1

PRODUCT CONTROL SECTION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: PAREX USA, INC.

SECTION 07530CP EPDM MEMBRANE ROOFING

4.2 Materials Membranes: inch, inch or inch thick D General

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

Adhered Roofing Systems with Aqua Base 120 Bonding Adhesive. UL/FM Code Approval Guide Table of Contents February 2012

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: COVESTRO, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

ESR-1794* Reissued September 1, 2012 This report is subject to renewal November 1, 2014.

EVALUATION REPORT Boral Roofing /MonierLifetile 7575 Irvine Center Drive Suite 100 Irvine, CA

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

PRODUCT CONTROL SECTION

LISTING INFORMATION OF Epilay - Superior, Ultra and Platinum Roofing Underlayments SPEC ID: Epilay Inc S. Main Street, E1 unit C

REPORT HOLDER: STAR R FOAM MANUFACTURING, INC. EVALUATION SUBJECT: STAR R FOAM INSULATION BOARDS

1. SUBJECT: DURO-LAST, DURO-LAST EV, DURO-TUFF, DURO-FLEECE, and DURO-FLEECE PLUS ROOFING MEMBRANES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

SECTION THERMOPLASTIC MEMBRANE ROOFING. C. Flashings. D. Roofing cant strips, stack boots, roofing expansion joints, and walkway pads.

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS

G October 2018

1 Exam Prep NRCA Roofing Manual: NRCA Roofing Manual: Membrane Roof Systems 2011 Tabs and Highlights

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

Transcription:

UL Evaluation Report UL ER10167-01 Issued: July 25, 2014 Visit UL s On-Line Certifications Directory: www.ul.com/erdirectory for current status of Report. UL Category Code: ULFB CSI MasterFormat DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Sub-level 2: 07 50 00 Membrane Roofing Sub-level 3: 07 54 00 Thermoplastic Membrane Roofing Sub-level 4: 07 54.23 Thermoplastic-Polyolefin Roofing COMPANY: Johns Manville 717 17 th Street Denver, CO 80202-3330 http://www.jm.com/ 1. SUBJECT: 45, 60, 72, 80 2. SCOPE OF EVALUATION FB 115, FB 135 2012, 2009 and 2006 International Building Code (IBC) 2012, 2009 and 2006 International Residential Code (IRC) ICC ES Acceptance Criteria for Roof-Covering Systems (AC75), Dated July 2010 ICC ES Acceptance Criteria for Quality Documentation (AC10), Dated December 2012 Page 1 of 34

The products were evaluated for the following properties: Roofing Systems for Exterior Fire Exposure (ANSI/UL 790, ASTM E108) Roofing Systems, Wind Uplift Resistance (FM 4474) Physical Properties (ASTM D6878, ASTM G155) Impact Resistance (FM 4470) Foot Traffic Resistance (FM 4470) 3. REFERENCED DOCUMENTS ANSI/UL 790 (ASTM E108), Standard Test Methods for Fire Tests of Roof Coverings FM 4474, Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and/or Negative Differential Pressures ASTM D6878 Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing ASTM G155, Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non- Metallic Materials FM 4470, Single-Ply, Polymer-Modified Bitumen Sheet, Built-Up Roof (BUR) and Liquid Applied Roof Assemblies for use in 1 and Noncombustible Roof Deck Construction FM 4474, Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and/or Negative Differential Pressures ICC ES Acceptance Criteria for Membrane Roof-Covering Systems (AC75), Dated July 2010 ICC ES Acceptance Criteria for Quality Documentation (AC10), Dated December 2012 4. USES The, FB and single-ply roof membranes are used as roof coverings in mechanically fastened or fully adhered A, B or C roof assemblies installed on combustible or noncombustible roof decks. 5. PRODUCT DESCRIPTION The, FB and membrane roofing systems described in this report consist of single-ply roofing membranes, insulation where used, barrier board or slip sheet where used, flashing, mechanical fasteners and adhesives that are installed on a combustible or non-combustible roof deck. The roofing assemblies incorporating the membranes comply with the following properties when installed as described in this report. Fire ification: Roofing assemblies covered under this report have been tested for fire classification A, B or C in accordance with ANSI/UL790 or (ASTM E108), as required by Section 1505.1 of 2012, 2009 and 2006 IBC and Section R902.1 of the 2012, 2009 and 2006 IRC. Wind Uplift Resistance: Roofing assemblies covered under this report have been tested for wind uplift resistance in accordance with FM 4474, and therefor qualify for use under Roofing membranes Section 1504.3.1 of the 2012, 2009 and 2006 IBC. Page 2 of 34

The roofing assemblies shall be designed to resist the design wind load pressures for components and cladding in accordance with Section 1609 of the 2012, 2009 and 2006 IBC and Section Section R905.1 of the 2012, 2009 and 2006 IRC. Physical Properties: The roofing membranes covered under this Report have been tested for physical properties in accordance with ASTM D6878 and ASTM G155, and therefore qualify for use under Section 1507.13.2 and Section 1504.6 of the 2012, 2009 and 2006 IBC and Section R905.13.2 of the 2012, 2009 and 2006 IRC. Impact Test: The single-ply roofing membranes covered under this Report have been tested for impact resistance in accordance with Resistance to Foot Traffic Test in Section 5.5 of FM 4470 and therefore qualify for use under Section 1504.7 of the 2012, 2009 and 2006 IBC. 5.1 Membranes: 5.1.1 : Thermoplastic, polyester reinforced membrane manufactured using an ultraviolet-resistance thermoplastic polyolefin formulation. 45 is a nominal 45 mil membrane and available in a white weathering surface (grey or tan are special order). The membrane is supplied in 500 sq ft, 800 sq ft or 1000 sq ft rolls. 60 is a nominal 60 mil membrane and available in a white, grey or tan weathering surface. The membrane supplied in 500 sq ft, 800 sq ft or 1000 sq ft rolls. 72 is a nominal 72 mil membrane and available in a white, grey or tan weathering surface. The membrane is supplied in 750 sq ft rolls and is a special order item. 80 is a nominal 80 mil membrane and available in a white weathering surface (grey or tan are special order). The membrane is supplied in 375 sq ft, 600 sq ft, or 750 sq ft rolls. is a nominal 60 mil membrane and available in a bright white weathering surface. The membrane is supplied in 1000 sq ft rolls and is a special order item. 5.1.2 FB: Thermoplastic polyolefin membrane with a reinforced polyester fabric and integral polyester fleece backing. 5.2 Insulation: FB115 is a nominal 60 mil membrane and available in white weathering surface (grey or tan are special order). The membrane is supplied in 1000 sq ft rolls. FB 135 is a nominal 80 mil membrane and available in white weathering surface (grey or tan are special order). The membrane is supplied in 500 sq ft rolls. Foam plastic insulation when used shall have a flame spread index of not more than 75 when tested at the maximum thickness intended for the use in accordance with ANSI/UL 723 or ASTM E 84 to qualify for use under Section 2603.3 and Exception 3 of the 2012, 2009 and 2006 IBC. To qualify for use under Section 2603.4.1.5 of the 2012, 2009 and 2006 IBC, a thermal barrier is not required for foam plastic insulation that is part of a A, B or C roof-covering assembly, provided the assembly with foam plastic insulation complies with FM 4450 or UL 1256. Page 3 of 34

5.3 Fasteners: Fasteners used to mechanically fasten insulation and membranes to the roof deck, shall be corrosion resistant and shall be one of the fasteners identified in Note 2 in the Appendix of this Report. 5.4 Adhesive: The adhesive used to adhere Johns Manville s TPO membranes to the insulation or roofing substrate shall be as noted in the Appendix of this Report. 5.4 Asphalt: Hot roofing asphalt, when specified in the roofing assemblies shall conform to ASTM D312, Type III or Type IV. 6. INSTALLATION Johns Manville single ply membranes shall be installed in accordance with the applicable code, this report and the manufacturer s published installation instructions. The membranes shall be installed in accordance with Section 1507.13 of the 2012, 2009 and 2006 IBC or Section R905.13 of the 2012, 2009 and 2006 IRC as applicable, except as noted in this report. The manufacturer s published installation instructions shall be available at all times on the jobsite during installation. The slope of the roof on which the membranes are installed shall be a minimum of 1/4:12 (2% slope) and shall not be more than the maximum slope indicated in the Tables in the Appendix of this Report. Penetrations and terminations of the roof covering shall be flashed and made watertight in accordance with the requirements of the membrane manufacturer, Section 1503.2 of 2012, 2009 and 2006 IBC or Section R903.2 of 2012, 2009 and 2006 IRC and applicable code. 7. Fire ification 7.1 New Construction: Roof assemblies utilizing Johns Manville 45, 60, 72, 80,, FB 115 and FB 135 thermoplastic single ply roof coverings are described in UL Certification Category for Roofing Systems, (TGFU), File R10167 (TGFU Link) and in Tables provided in the Appendix. 7.2 Reroofing: The existing roof shall be inspected in accordance with the provisions and limitations of Section 1510 of the 2012, 2009 and 2006 or Section R907 of the 2012, 2009 and 2006 IRC, as applicable. The existing deck shall be inspected to verify that the structure to be reroofed is structurally sound and adequate to support and secure the roofing membrane. Prior to installation of new roof coverings, inspection by and approval from the code official having jurisdiction is required. Johns Manville membranes may be installed over existing ified A, B or C roofing systems as described in the UL Certification Category for Roofing Systems (TGFU), File R10167 (TGFU Link) under the heading A, B and C (TPO) for Maintenance and Repair for applicable coverage and details of the roof assemblies and in the Tables in the Appendix of this Report. Page 4 of 34

A, B or C roof coverings may be installed over existing classified roof assemblies under the following conditions without additional roof classification tests, provided the resulting classification is the lower of the new and existing roof classifications under the following conditions: New uninsulated roof coverings installed only over existing uninsulated assemblies. New insulated roof coverings installed over existing uninsulated assemblies only. 8. Wind Resistance 8.1 New Construction: The allowable wind uplift pressures for the roof assemblies are noted in the Tables in Appendix of this Report. Metal edge securement for all systems shall be designed in accordance with ANSI/SPRI ES-1, complying with Section 1504.5 of 2012, 2009 and 2006 IBC. For certifications of metal edge securement systems in accordance with ANSI/SPRI ES-1, See UL Online Certifications Directory Roof-edge Systems, Metal for Use with Low-slope Roofing Systems (TGJZ). 8.2 Reroofing: Roof covering systems employing mechanical fasteners shall be qualified, to the satisfaction of the code official, as to the adequacy of fasteners penetrating through existing roof coverings into structural substrates. Since the composition and/or conditions of any particular underlying existing roofing materials may vary and reroofing material may vary, reroofing with adhered systems is outside the scope of this report. 9. CONDITIONS OF USE The Johns Manville single ply roofing membranes described in this Report comply with, or are suitable alternatives to, what is specified in those codes listed in Section 2 of this Report, subject to the following conditions: 9.1 Materials and methods of installation shall comply with this Report and the manufacturer s published installation instructions. In the event of a conflict between the installation instructions and this Report, this Report governs. 9.2 Johns Manville thermoplastic single ply roofing membranes shall be installed by professional roofing contractors trained and approved by the manufacturer. 9.3 See UL Online Certification Directory Roofing Systems (TGFU) File R10167. (TGFU Link) Also refer to the Tables in the Appendix of this Report. 9.4 Above-deck thermal insulation board shall comply with the applicable standards listed in Table 1508.2 in Section 1508.2 of 2012, 2009 and 2006 IBC. 9.5 Wind uplift pressures on any roof area, including edges and corner zones shall not exceed the allowable wind pressure for the roof covering installed in that particular area. Refer to the Tables in the Appendix of this Report. 9.6 The allowable wind uplift pressures listed in the Tables in the Appendix of this Report are for the roof systems only. The deck and framing to which the roofing system is attached shall be designed for the applicable components and cladding, wind loads in accordance with the applicable codes. 9.7 When application is over an existing roof, documentation of the wind uplift resistance of the composite roof construction shall be submitted to the code official. Page 5 of 34

9.8 The metal edge securement shall be designed and installed for wind loads in accordance with Chapter 16 of 2012, 2009 and 2006 IBC and test for resistance in accordance with Test Methods RE-1, RE-2 and RE-3 of ANSI/SPRI ES-1, except V ult wind speed shall be determined from Figure 1609A, 1609B, or 1609C of 2012, 2009 and 2006 IBC as applicable. 9.9 The Johns Manville thermoplastic single ply membranes covered under this report are produced by Johns Manville in Scottsboro, AL under the UL LLC ification and Follow-Up Service Program, which includes audits in accordance with quality elements of ICC-ES Acceptance Criteria for Quality Documentation, AC 10. 10. SUPPORTING EVIDENCE 10.1 Data in accordance with ICC-ES Acceptance Criteria for Membrane Roof-Covering Systems, AC75. 10.2 Manufacturer s descriptive product literature, including installation instructions. 10.3 UL ification Reports in accordance with ANSI/UL 790. See UL Product Certification Category for Roofing Systems (TGFU), File R10167. 10.4 Data in accordance with FM 4474. 10.5 Data in accordance with FM 4470. 10.6 Data in accordance with ASTM D6878 and ASTM G155. 10.7 Documentation of quality system elements in accordance with ICC-ES Acceptance Criteria for Quality Documentation, AC10. 11. IDENTIFICATION The Johns Manville thermoplastic single ply membranes described in this evaluation report are identified by a marking bearing the report holder s name (Johns Manville), the plant identification (if required), the product designation, the UL ification Mark, and the evaluation report number UL ER10167-01. The validity of the evaluation report is contingent upon this identification appearing on the product or UL ification Mark certificate. 12. USE OF UL EVALUATION REPORT 12.1 The approval of building products, materials or systems is under the responsibility of the applicable authorities having jurisdiction. 12.2 UL Evaluation Reports shall not be used in any manner that implies an endorsement of the product, material or system by UL. 12.3 The current status of this report, as well as a complete directory of UL Evaluation Reports may be found at UL.com via our On-Line Certifications Directory: www.ul.com/database www.ul.com/erdirectory Page 6 of 34

APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description 1A Wood New, Reroof (Tear-Off), Recover C Mechanically Attached Insulation, Bonded Roof Cover 1B Wood New, Reroof (Tear-Off), Recover D Insulated, Mechanically Attached Roof Cover 2A Steel or Conc. New, Reroof (Tear-Off), Recover B Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 2B-1 Steel or Conc. New, Reroof (Tear-Off), Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 2B-1 Steel or Conc. New, Reroof (Tear-Off), Recover C-2 Mechanically Attached Insulation, Plate-Bonded or Strip-Bonded Roof Cover 2C Steel or Conc. New, Reroof (Tear-Off), Recover D Insulated, Mechanically Attached Roof Cover 3A-1 Concrete New, Reroof (Tear-Off) A-1a Bonded Insulation, Bonded Roof Cover 3A-2 Concrete New, Reroof (Tear-Off) A-1b Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover 4A LWIC New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 5A Gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 6A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 6B Various Recover Over Existing Metal Roof C-2 Mech. Attached Insulation, Plate-Bonded Roof Cover 6C Various Recover Over Existing Metal Roof D Insulated, Mechanically Attached Roof Cover 6D Various Recover F Non-Insulated, Bonded Roof Cover The following notes apply to the systems outlined herein: 1. Roof decks shall be in accordance with IBC or IRC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. Wind load resistance of the roof deck shall be documented through proper codified Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: Steel Deck: UltraFast #12 or #14 with UltraFast 3 in. Round Metal Plates or UltraFast Square Recessed Metal Plates. Minimum ¾-inch steel penetration, engage the top flute of the steel deck. Concrete Deck: UltraFast #14 with UltraFast 3 in. Round Metal Plates or UltraFast Square Recessed Metal Plates or JM Structural Concrete Deck Fasteners and Plates. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer s published installation instructions. 3. Minimum 200 psi, minimum 2-inch thick lightweight insulating may be substituted for rigid insulation board for System Type D (mechanically attached membrane), whereby the membrane fasteners are installed through the LWIC to engage the structural steel or deck. The structural deck shall be of equal or greater configuration to the steel and deck listings. 4. Preliminary insulation attachment for System Type D = Minimum four fasteners per 4 x 8 ft board or minimum two fasteners per 4 x 4 ft board. Page 7 of 34

5. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer s published instructions: Hot asphalt [HA]: Full coverage at 20-25 lbs/sq. JM Urethane Insulation Adhesive [JM UIA]: Continuous 0.75-inch ribbons, 12-inch o.c. JM Two-Part Urethane Insulation Adhesive [TWO-]: Continuous 0.75-inch ribbons, 12-inch o.c. Note: JM Green Two-Part Urethane Insulation Adhesive may be used where UIA-TWO- is referenced JM Roofing System Urethane Adhesive (JM-RSUA): Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c. JM One-Step Foamable Adhesive [JM-OSFA]: Continuous 0.75-inch ribbons, 12-inch o.c. Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, adhesive ribbons shall be staggered from layer-to-layer a distance of onehalf the ribbon spacing. Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing 6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following imum Design Pressure () limitations. In no case shall these values be used to increase the listings in the tables; rather if listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: JM Two-Part Urethane Insulation Adhesive [TWO-]: : -315.0 psf (Min. 0.5-inch thick) JM Roofing System Urethane Adhesive (JM RSUA): -157.5 psf (Min. 0.5-inch thick) JM One-Step Foamable Adhesive [JM-OSFA]: : -157.5 psf (Min. 0.5-inch thick) 7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 8. For System Type D, steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes. 9. For Recover Applications using System Type D, the insulation is optional. Alternatively, min. 0.25-inch Invinsa, DensDeck, DensDeck Prime, Gypsum-Fiber Roof may be used as a separator board, preliminarily attached prior to roof cover installation. The existing roof system shall be suitable for a recover application. 10. For adhered membrane systems, side laps shall be minimum 2-inch wide sealed with min. 1.5-inch heat weld. Adhesive application rates are as follows: Membrane Adhesive Method Rate Membrane Adhesive (Solvent Based) [ MA-SB] Contact (both sides) 1.67 gal/square (½ applied to substrate and ½ applied to membrane) Membrane Adhesive (Low VOC) [ MA-LVOC] Contact (both sides) 1.67 gal/square (½ applied to substrate and ½ applied to membrane) Membrane Adhesive (Water Based) [ ] Wet lay (substrate) 1.10 gal/square FB Membrane Adhesive (Water Based) [ ] Wet lay (substrate) 0.83 to 1 gal/square FB JM Roofing System Urethane Adhesive (JM-RSUA) Wet lay (substrate) 0.5 to 0.75-inch wide ribbons spaced as noted in tables herein. 11. = imum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind loads. Page 8 of 34

W-1 Deck (See Note 1) Min 3/4 in. plywood or wood plank at max 24 in. spans TABLE 1A-1: WOOD DECKS - NEW CONSTRUCTION or REROOF (Tear-Off) or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Base Insulation Layer Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, JM ISO 3, ValuTherm, ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF, loose laid Top Insulation Layer Roof Cover Type Fasteners Attach Type Attach Min. 7/16-in. OSB See Note 2 1 per 2 ft² FB115-45.0 A 1/2 TABLE 1B-1: WOOD DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED ROOF COVER (STRESS PLATES) Insulation Roof Cover System Deck (See Note 1) Type Attachment Membrane Fasteners Attachment W-2 Min. 19/32 in. plywood at 24 in. spans with blocking at unsupported joints attached with 10d ring shank nails spaced 4-in. oc at perimeter and intermediate supports Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, JM ISO 3, ValuTherm, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Prelim. attached 45, (8 ft sheet) High Load Fasteners with High Load Seam Plates 6-in. oc within 6-in. wide laps spaced 90-in. oc Laps sealed with 1.5-in. heat weld outside lap -60.0 A 1/2 Page 9 of 34

Deck (See Note 1) APPLICATIONS: SC-1 SC-2 type B, Grade 33 steel or min. 2,500 psi type B, Grade 33 steel or min. 2,500 psi FB APPLICATIONS: SC-3 SC-4 SC-5 SC-6 type B, Grade 33 steel or min. 2,500 psi type B, Grade 33 steel or min. 2,500 psi type B, Grade 33 steel or min. 2,500 psi type B, Grade 33 steel or min. 2,500 psi TABLE 2A: STEEL or CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear-Off) or RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover Type Fastener Attach Type Attach Type Attach Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm CGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm CGF, ValuTherm 25 PSI CGF Min. 1.5-in. ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm CGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm CGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm CGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm CGF, ValuTherm 25 PSI CGF See Note 2 See Note 2 See Note 2 See Note 2 See Note 2 See Note 2 1 per 2 ft² 1 per 2 ft² 1 per 2 ft² 1 per 2 ft² 1 per 2 ft² 1 per 2 ft² Min. 0.5-in. RetroPlus Min. 0.5-inch RetroPlus Additional layer(s) base insulation Additional layer(s) base insulation Additional layer(s) base insulation Min. 0.5-inch RetroPlus TWO- JM-RSUA JM UIA Hot Asphalt TWO- TWO- 45, 45, FB 115 FB 115 FB 115 115, JM TPO MA-SB MA-LVOC, JM TPO MA-SB MA-LVOC -45.0-45.0 A 1/2 A 3/4 A 1/2 A 3/4-45.0 A 1/2-45.0 A 1/2-45.0 A 1/2-45.0 A 1/2 Page 10 of 34

SC-7 SC-8 SC-9 SC-10 SC-11 SC-12 Deck (See Note 1) type B, Grade 33 steel or type B, Grade 33 steel or type B, Grade 33 steel or type B, Grade 33 steel or type B, Grade 33 steel or type B, Grade 33 steel or TABLE 2A: STEEL or CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear-Off) or RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover Type Fastener Attach Type Attach Type Attach Min. 2-in. ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ValuTherm 25 PSI AGF, Min. 2-in. ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ValuTherm 25 PSI AGF, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ValuTherm 25 PSI AGF, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ValuTherm 25 PSI AGF, Min. 2-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ValuTherm 25 PSI AGF, Min. 2-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ValuTherm 25 PSI AGF, See Note 2 See Note 2 See Note 2 See Note 2 See Note 2 See Note 2 1 per 4 ft² 1 per 2.67 ft² 1 per 2 ft² 1 per 1 ft² 1 per 4 ft² 1 per 2.67 ft² Min. 0.25-in Gypsum-Fiber Roof Min. 0.25-in Gypsum-Fiber Roof Min. 0.5-inch RetroPlus Min. 0.5-inch Invinsa or Gypsum-Fiber Roof Gypsum-Fiber Roof Gypsum-Fiber Roof TWO- TWO- JM-RSUA JM-RSUA JM-OSFA JM-OSFA FB 115 FB 115 FB 115 FB 115 FB 115 FB 115 JM-RSUA, 12-inch o.c. -37.5 A 2-45.0 A 2-45.0 A 1/2-67.5 A 1/2-37.5 A 2-45.0 A 2 Page 11 of 34

Roof Deck APPLICATIONS: SC-13 SC-14 SC-15 SC-16 SC-17 type B, type B, type B, type B, type B, TABLE 2B-1: STEEL or CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Base Insulation Layer (Optional) One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination, loose laid One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 25 PSI CGF, ValuTherm AGF, ValuTherm 25 PSI AGF,, any combination, loose laid One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 25 PSI CGF, ValuTherm AGF, ValuTherm 25 PSI AGF,, any combination, loose laid One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 25 PSI CGF, ValuTherm AGF, ValuTherm 25 PSI AGF,, any combination, loose laid One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 25 PSI CGF, ValuTherm AGF, ValuTherm 25 PSI AGF,, any combination, loose laid Top Insulation Layer Roof Cover Type Fasteners Attach Type Attach Min. 1.75-inch Invinsa Foam Invinsa Dens Deck Gypsum-Fiber Roof Gypsum-Fiber Roof See Note 2 See Note 2 See Note 2 See Note 2 See Note 2 1 per 4 ft² 1 per 2 ft² 1 per 2 ft² 1 per 2.67 ft² 1 per 2.67 ft² 45, 45, 45, 45, 45, MA- WB, MA-SB MA- LVOC MA- WB, MA-SB MA- WB, MA-SB MA- WB MA- LVOC -30.0 A 1/2 A 3-30.0 A 1/2-30.0 A 3/4-37.5 A 1/2-37.5 A 3/4 Page 12 of 34

SC-18 SC-19 SC-20 SC-21 Roof Deck type B, type B, type B, type B, TABLE 2B-1: STEEL or CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Base Insulation Layer (Optional) One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination, loose laid (Optional) One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination, loose laid (Optional) One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination, loose laid One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 25 PSI CGF, ValuTherm AGF, ValuTherm 25 PSI AGF,, any combination, loose laid Top Insulation Layer Roof Cover Type Fasteners Attach Type Attach Min. 2-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, JM ISO 3, ValuTherm, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 2-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, JM ISO 3, ValuTherm, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, JM ISO 3, ValuTherm, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.75-inch Invinsa Foam See Note 2 See Note 2 See Note 2 See Note 2 1 per 4 ft² 1 per 4 ft² 1 per 2 ft² 1 per 2.9 ft² 45, 45, 45, 45, MA- WB MA- SB MA- LVOC MA- WB, MA-SB -MA- LVOC MA- WB, MA-SB MA- LVOC -37.5 A 1/2-45.0-45.0-45.0 A 1/2 A 3/4 A 1/2 A 3/4 A 1/2 A 3/4 Page 13 of 34

SC-22 SC-23 SC-24 Roof Deck type B, type B, type B, TABLE 2B-1: STEEL or CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Base Insulation Layer One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI,, any combination, loose laid One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI,, any combination, loose laid (Optional) One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI,, any combination, loose laid Top Insulation Layer Roof Cover Type Fasteners Attach Type Attach Min. 0.625-inch Gypsum-Fiber Roof Min. 7/16-inch APA rated OSB Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, JM ISO 3, ValuTherm, ValuTherm AGF, ValuTherm 25 PSA CGF See Note 2 See Note 2 See Note 2 1 per 4 ft² 1 per 2 ft² 1 per 1.78 ft² 45, 60, 72 or 80, 45, 60, 72 or 80, 45, 60, 72 or 80, MA- WB, MA-SB MA- LVOC MA- WB, MA-SB MA- SB MA- LVOC -45.0 A 1/2 A 3/4-45.0 A 1/2-52.5 A 1/2 A 3/4 Page 14 of 34

SC-25 Roof Deck type B, FB APPLICATIONS: SC-26 SC-27 type B, type B, TABLE 2B-1: STEEL or CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Base Insulation Layer One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI,, any combination, loose laid One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI,, any combination, loose laid One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI,, any combination, loose laid Top Insulation Layer Roof Cover Type Fasteners Attach Type Attach Min. 7/16-inch APA rated OSB Min. 2-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, JM ISO 3, ValuTherm, ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Gypsum-Fiber Roof See Note 2 See Note 2 See Note 2 1 per 1.78 ft² 1 per 4 ft² 1 per 2.67 ft² 45, 60, 72 or 80, FB 115 or 135 FB 115 or 135 MA- SB, MA- LVOC MA- WB MA- WB -75.0 A 1/2 A 3/4-37.5 A 1/2-37.5 A 1/2 Page 15 of 34

SC-28 SC-29 SC-30 Roof Deck type B, type B, type B, TABLE 2B-1: STEEL or CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Base Insulation Layer One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI,, any combination, loose laid One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI,, any combination, loose laid One or more layers, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI,, any combination, loose laid Top Insulation Layer Roof Cover Type Fasteners Attach Type Attach Min. 2-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, JM ISO 3, ValuTherm, ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF See Note 2 1 per 2 ft² Min. 7/16-inch OSB See Note 2 1 per 2 ft² Min. 5/8 Gypsum-Fiber Roof See Note 2 1 per 4 ft² FB 115 or 135 FB 15 or 135 FB 15 or 135 MA- WB MA- WB MA- WB -45.0 A 1/2-45.0 A 1/2-45.0 A 1/2 Page 16 of 34

SC-31 SC-32 SC-33 SC-34 SC-35 Deck (See Note 1) 33 steel at max. 6 ft span or min. 2,500 psi 33 steel at max. 6 ft span or min. 2,500 psi 33 steel at max. 6 ft span or min. 2,500 psi 33 steel at max. 6 ft span or min. 2,500 psi 33 steel at max. 6 ft span or min. 2,500 psi TABLE 2B-2: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, PLATE-BONDED OR STRIP-BONDED ROOF COVER Insulation Layer ENRGY 3 25 PSI CGF, ValuTherm AGF, ValuTherm 25 PSI AGF,, any combination ENRGY 3 25 PSI CGF, ValuTherm AGF, ValuTherm 25 PSI AGF,, any combination ENRGY 3 25 PSI CGF, ValuTherm AGF, ValuTherm 25 PSI AGF,, any combination ENRGY 3 25 PSI CGF, ValuTherm AGF, ValuTherm 25 PSI AGF,, any combination ENRGY 3 25 PSI CGF, ValuTherm AGF, ValuTherm 25 PSI AGF,, any combination Attachment Roof Cover / Adhesive Fasteners Spacing RhinoPlates and High Load Fasteners RhinoPlates and High Load Fasteners RhinoPlates and High Load Fasteners RhinoPlates and High Load Fasteners RhinoPlates and High Load Fasteners 18-inch o.c. at rows spaced 60- inch o.c. 6-inch o.c. at rows spaced 120- inch o.c. 12-inch o.c. at rows spaced 60- inch o,c. 6-inch o.c. at rows spaced 60- inch o.c. 1 per 5.33 ft² (6 parts per 4 x 8 ft board) 45, bonded to RhinoPlates with Rhinobond Plate bonding tool at 6 seconds per plate so tool reaches 400 F and cooled with RhinoBond Cooling Clamps. Laps sealed with 1.5-inch heat weld 45, bonded to RhinoPlates with Rhinobond Plate bonding tool at 6 seconds per plate so tool reaches 400 F and cooled with RhinoBond Cooling Clamps. Laps sealed with 1.5-inch heat weld. 45, bonded to RhinoPlates with Rhinobond Plate bonding tool at 6 seconds per plate so tool reaches 400 F and cooled with RhinoBond Cooling Clamps. Laps sealed with 1.5-inch heat weld. 45, bonded to RhinoPlates with Rhinobond Plate bonding tool at 6 seconds per plate so tool reaches 400 F and cooled with RhinoBond Cooling Clamps. Laps sealed with 1.5-inch heat weld. 45, bonded to RhinoPlates with Rhinobond Plate bonding tool at 6 seconds per plate so tool reaches 400 F and cooled with RhinoBond Cooling Clamps. Laps sealed with 1.5-inch heat weld. -37.5 A 3/4-45.0 A 3/4-52.5 A 3/4-105.0 A 3/4-45.0 A 3/4 Page 17 of 34

SC-36 SC-37 Deck (See Note 1) 33 steel at max. 6 ft span or min. 2,500 psi 33 steel at max. 6 ft span or min. 2,500 psi TABLE 2B-2: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, PLATE-BONDED OR STRIP-BONDED ROOF COVER Insulation Layer ENRGY 3 25 PSI CGF, ValuTherm AGF, ValuTherm 25 PSI AGF,, any combination ENRGY 3 25 PSI CGF, ValuTherm AGF, ValuTherm 25 PSI AGF,, any combination Attachment Roof Cover / Adhesive Fasteners Spacing RhinoPlates and High Load Fasteners 10 RPS fastened with JM High Load Seam Plates and High Load Fasteners 1 per 4 ft² (8 parts per 4 x 8 ft board) Fasteners 6-inch o.c. through RPS at rows spaced 114-inch o.c. 45, bonded to RhinoPlates with Rhinobond Plate bonding tool at 6 seconds per plate so tool reaches 400 F and cooled with RhinoBond Cooling Clamps. Laps sealed with 1.5-inch heat weld. 45, underside is primed with Primer 240 or ADCO SPC-3 Primer and walked-in over the self-adhering RPS. Laps sealed with 1.5-inch heat weld. -67.5 A 3/4-52.5 A 3/4 Page 18 of 34

Deck (See Note 1) TABLE 2C: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED ROOF COVER SYSTEMS OVER MIN. GRADE 33 STEEL DECK OR STRUCTURAL CONCRETE (AS NOTED) 33 steel or ENRGY 3 25 Prelim. SC-38 PSI CGF, attached structural ValuTherm 25 PSI CGF, any combination SC-39 SC-40 SC-41 SC-42 33 steel or structural 33 steel or structural 33 steel or structural 33 steel or structural Insulation Roof Cover Type Attach Membrane Fasteners Attachment ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination Prelim. attached Prelim. attached Prelim. attached Prelim. attached 45, 60, 72 or 80, (8 ft sheet) 45, 60, 72 or 80, (10 ft sheet) 45, 60, 72 or 80, (10 ft sheet) 45, 60, 72 or 80, (8 ft sheet) 45, 60, 72 or 80, (10 ft sheet) High Load Fasteners (steel or ) or JM Structural Concrete Deck Fasteners ( only) with High Load SeamPlates High Load Fasteners (steel or ) or JM Structural Concrete Deck Fasteners ( only) with High Load Seam Plates Extra High Load Fasteners (steel only) or JM Structural Concrete Deck Fasteners ( only) with Extra High Load Seam Plates Extra High Load Fasteners (steel only) or JM Structural Concrete Deck Fasteners ( only) with Extra High Load Seam Plates High Load Fasteners (steel or ) or JM Structural Concrete Deck Fasteners ( only) with High Load Seam Plates 12-inch o.c. within 6- inch wide laps spaced 90-inch o.c. Laps sealed with 1.5-inch heat weld outside lap 12-inch o.c. within 6- inch wide laps spaced 114-inch o.c. Laps sealed with 1.5-inch heat weld outside lap 12-inch o.c. within 6- inch wide laps spaced 114-inch o.c. Laps sealed with 1.5-inch heat weld outside lap 12-inch o.c. within 6- inch wide laps spaced 90-inch o.c. Laps sealed with 1.5-inch heat weld outside lap 6-inch o.c. within 6- inch wide laps spaced 114-inch o.c. Laps sealed with 1.5-inch heat weld outside lap -30.0 A 3/4-30.0 A 3/4-37.5 A 3/4-45.0 A 3/4-45.0 A 3/4 Page 19 of 34

SC-43 SC-44 SC-45 Deck (See Note 1) 33 steel or structural 33 steel or structural 33 steel or structural TABLE 2C: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED ROOF COVER Insulation Roof Cover Type Attach Membrane Fasteners Attachment ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination Min. 2-inch thick, one or more ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination Prelim. attached Prelim. attached Prelim. attached 45, 60, 72 or 80, (8 ft sheet) 45, 60, 72 or 80, (5 ft sheet) 45, 60, 72 or 80, SYSTEMS OVER MIN. GRADE 80 STEEL DECK OR STRUCTURAL CONCRETE (AS NOTED) 45, 60, 72 SC-46 80 steel or ENRGY 3 25 Prelim. or 80, PSI CGF, attached (8 ft structural ValuTherm 25 PSI CGF, any combination sheet) SC-47 80 steel or structural ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination Prelim. attached 45, 60, 72 or 80, (10 ft sheet) High Load Fasteners (steel or ) or JM Structural Concrete Deck Fasteners ( only) with High Load Seam Plates High Load Fasteners (steel or ) or JM Structural Concrete Deck Fasteners ( only) with High Load Seam Plates High Load Fasteners (steel or ) or JM Structural Concrete Deck Fasteners ( only) with High Load Seam Plates High Load Fasteners (steel or ) or JM Structural Concrete Deck Fasteners ( only) with High Load Seam Plates High Load Fasteners (steel or ) or JM Structural Concrete Deck Fasteners ( only) with High Load Seam Plates 6-inch o.c. within 6- inch wide laps spaced 90-inch o.c. Laps sealed with 1.5-inch heat weld outside lap 6-inch o.c. within 6- inch wide laps spaced 54-inch o.c. Laps sealed with 1.5-inch heat weld outside lap 12-inch o.c. within 6- inch wide laps spaced 114-inch o.c. Laps sealed with 1.5-inch heat weld outside lap 12-inch o.c. within 6- inch wide laps spaced 90-inch o.c. Laps sealed with 1.5-inch heat weld outside lap 12-inch o.c. within 6- inch wide laps spaced 114-inch o.c. Laps sealed with 1.5-inch heat weld outside lap -60.0 A 3/4-82.5 A 3/4-30.0 A 3/4-37.5 A 3/4-37.5 A 3/4 Page 20 of 34

SC-48 SC-49 SC-50 SC-51 SC-52 Deck (See Note 1) 80 steel or structural 80 steel or structural 80 steel or structural 80 steel or structural 80 steel or structural TABLE 2C: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED ROOF COVER Insulation Roof Cover Type Attach Membrane Fasteners Attachment ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination ENRGY 3 25 PSI CGF, ValuTherm 25 PSI CGF, any combination Prelim. attached Prelim. attached Prelim. attached Prelim. attached Prelim. attached 45, 60, 72 or 80, (8 ft sheet) 45, 60, 72 or 80, (10 ft sheet) 45, 60, 72 or 80, (10 ft sheet) 45, 60, 72 or 80, (10 ft sheet) 45, 60, 72 or 80, (8 ft sheet) Extra High Load Fasteners (steel only) or JM Structural Concrete Deck Fasteners ( only) with Extra High Load Seam Plates High Load Fasteners (steel or ) or JM Structural Concrete Deck Fasteners ( only) with High Load Seam Plates Extra High Load Fasteners (steel only) or JM Structural Concrete Deck Fasteners ( only) with Extra High Load Seam Plates Extra High Load Fasteners (steel only) or JM Structural Concrete Deck Fasteners ( only) with Extra High Load Seam Plates High Load Fasteners (steel or ) or JM Structural Concrete Deck Fasteners ( only) with High Load Seam Plates 12-inch o.c. within 6- inch wide laps spaced 90-inch o.c. Laps sealed with 1.5-inch heat weld outside lap 6-inch o.c. within 6- inch wide laps spaced 114-inch o.c. Laps sealed with 1.5-inch heat weld outside lap 12-inch o.c. within 6- inch wide laps spaced 114-inch o.c. Laps sealed with 1.5-inch heat weld outside lap 6-inch o.c. within 6- inch wide laps spaced 114-inch o.c. Laps sealed with 1.5-inch heat weld outside lap 6-inch o.c. within 6- inch wide laps spaced 90-inch o.c. Laps sealed with 1.5-inch heat weld outside lap -45.0 A 3/4-45.0 A 3/4-45.0 A 3/4-52.5 A 3/4-52.5 A 3/4 Page 21 of 34

Roof Deck APPLICATIONS: C-1 C-2 C3 C-4 C-5 Primer TABLE 3A-1: CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear-Off) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover Type Attach Type Attach Type Attach Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF,, Invinsa Foam Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, ValuTherm CGF,, Invinsa Foam JM UIA JM UIA JM UIA TWO- TWO- (Optional) Min. 0.25-inch DensDeck or Invinsa Invinsa (Optional) Additional layers of base insulation Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, JM ISO 3, ValuTherm, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.5-inch Invinsa Foam JM UIA JM UIA JM UIA TWO- TWO- 45, 60, TPO 45, 60, TPO 45, 60, TPO 45, 60, TPO 45, 60, TPO, JM TPO MA-SB or MA-SB -75.0 A 1/2-112.5 A 1/2 MA-SB A 1/2-217.5 MA-LVOC A 3/4 MA-LVOC, JM TPO MA-SB MA-LVOC -330.0 A 3/4-330.0 A 1/2 A 3/4 Page 22 of 34

C-6 C-7 C-8 C-9 C-10 Roof Deck Primer TABLE 3A-1: CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear-Off) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover Type Attach Type Attach Type Attach Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, TWO- OR JM UIA TWO- TWO- JM-RSUA JM-OSFA (Optional) Min. 0.25-inch DensDeck or Invinsa Invinsa Gypsum-Fiber Roof Gypsum-Fiber Roof (Optional) Min. 0.25-inch DensDeck or Invinsa TWO- OR JM UIA TWO- TWO- JM-RSUA JM-OSFA 45, 60, TPO 45, 60, TPO 45, 60, TPO 45, 60, TPO 45, 60, TPO, JM TPO MA-SB or MA-SB, JM TPO MA-SB MA-LVOC, JM TPO MA-SB MA-LVOC, JM TPO MA-SB -105.0 A 1/2-105.0 A 1/2-247.5-247.5 A 1/2 A 3/4 A 1/2 A 3/4-75.0 A 1/2 Page 23 of 34

C-11 Roof Deck FB APPLICATIONS: Primer TABLE 3A-1: CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear-Off) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover Type Attach Type Attach Type Attach Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, JM-OSFA Gypsum-Fiber Roof JM-OSFA 45, 60, TPO, JM TPO MA-SB MA-LVOC -247.5 A 1/2 A 3/4 C-12 C-13 C-14 C-15 C-16 C-17 ASTM D41 ASTM D41 Min. 1.5-inch ENRGY 3, ValuTherm Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, Min. 1.5-inch ENRGY 3, ValuTherm Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, TWO- TWO- JM-RSUA JM-RSUA HA HA (Optional) Additional layers of base insulation Min. 0.5-inch Invinsa or Gypsum-Fiber Roof (Optional) Additional layers of base insulation Min. 0.5-inch Invinsa or Gypsum-Fiber Roof (Optional) Additional layers of base insulation Gypsum-Fiber Roof TWO- TWO- JM-RSUA JM-RSUA HA HA FB 115 FB 115 FB 115 FB 115 FB 115 FB 115 JM-RSUA, 12-inch o.c. JM-RSUA, 12-inch o.c. JM-RSUA, 12-inch o.c. JM-RSUA, 12-inch o.c. -67.5 A 1/2-67.5 A 1/2-67.5 A 1/2-67.5 A 1/2-105.0 A 1/2-105.0 A 2 Page 24 of 34

C-18 C-19 C-20 C-21 C-22 C-23 Roof Deck Primer TABLE 3A-1: CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear-Off) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover Type Attach Type Attach Type Attach Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, Min. 2-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, JM ISO 3, ValuTherm, ValuTherm AGF, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, Min. 2-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, JM ISO 3, ValuTherm, ValuTherm AGF, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM ISO 3, ValuTherm, ValuTherm AGF, Min. 2-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, JM ISO 3, ValuTherm, ValuTherm AGF, JM UIA JM UIA TWO- TWO- JM-OSFA JM-OSFA (Optional) Additional layers of base insulation Gypsum-Fiber Roof (Optional) Additional layers of base insulation Gypsum-Fiber Roof (Optional) Additional layers of base insulation Gypsum-Fiber Roof JM UIA JM UIA TWO- TWO- JM-OSFA JM-OSFA FB 115 FB 115 FB 115 FB 115 FB 115 FB 115-105.0 A 1/2-105.0 A 2-105.0 A 1/2-105.0 A 2-105.0 A 1/2-105.0 A 2 Page 25 of 34

Deck (See Note 1) FB APPLICATIONS: Primer TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear-Off) SYSTEM TYPE A-1B: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER Temporary Roof Base Insulation Layer Top Insulation Layer Roof Cover Type Attach Type Attach Type Attach Type Attach (psf C-24 C-25 C-26 C-27 Min. 2,500 psi Min. 2,500 psi Min. 2,500 psi Min. 2,500 psi JM SA Primer Low VOC JM SA Primer Low VOC JM SA Primer Low VOC JM SA Primer Low VOC JM Vapor Barrier SA JM Vapor Barrier SA JM Vapor Barrier SA JM Vapor Barrier SA Self- Adhered Self- Adhered Self- Adhered Self- Adhered Min. 1.5-inch ENRGY 3, ValuTherm Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, JM ISO 3, ValuTherm, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3, ValuTherm Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, JM ISO 3, ValuTherm, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF TWO- TWO- JM-RSUA JM-RSUA (Optional) Additional layers of base insulation Min. 0.5-inch Invinsa or Gypsum-Fiber Roof or min. 1.5-inch Invinsa Foam (Optional) Additional layers of base insulation Min. 0.5-inch Invinsa or Gypsum-Fiber Roof TWO- TWO- JM-RSUA JM-RSUA FB 115 FB 115 FB 115 FB 115 JM-RSUA, 12-inch o.c. JM-RSUA, 12-inch o.c. JM-RSUA, 12-inch o.c. JM-RSUA, 12-inch o.c. -67.5 A 1/2-67.5 A 1/2-67.5 A 1/2-67.5 A 1/2 Page 26 of 34

LWC-1 LWC-2 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER Deck (See Note 1) Roof Cover Structural LWC Type Attach Min. 379 psi, min. 2 thick Concrecel Concrete, with optional 1 thick, 1.0 pcf EPS holey board and surfacing of Concrecel Curing Compound. Min. 350 psi, min. 2 thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture, with optional 1 thick, 1.0 pcf EPS holey board and surfacing of Celcore PVA Curing Compound. 45, 60, 72 or 80, 45, 60, 72 or 80, MA-LVOC -285.0 A 3/4 MA-LVOC -367.5 A 3/4 Page 27 of 34

Deck (See Note 1) APPLICATIONS: TABLE 5A: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover Type Attach Type Attach Type Attach G-1 G-2 Existing poured gypsum or gypsum plank Existing poured gypsum or gypsum plank FB APPLICATIONS: Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, JM ISO 3, ValuTherm, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, JM ISO 3, ValuTherm, TWO- TWO- (Optional) Min. 0.25- inch DensDeck or Invinsa or min. 1.5-inch Invinsa Foam (Optional) Additional layers of base insulation TWO- TWO- 45, 45,, MA-SB or TACC FA- 141 MA-SB, MA- LVOC or TACC FA-141-105.0 A 1/2-112.5 A 1/2 G-3 Existing poured gypsum or gypsum plank Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, JM ISO 3, ValuTherm, TWO- (Optional) Additional layers of base insulation or Min. 0.25- inch Gypsum-Fiber Roof TWO- FB 115-105.0 A 1/2 Page 28 of 34

Substrate APPLICATIONS: TABLE 6A: RECOVER APPLICATIONS SYSTEM TYPE A: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover Type Attach Type Attach Type Attach R-1 Existing asphaltic BUR R-2 Existing asphaltic BUR R-3 Existing asphaltic BUR R-4 Existing asphaltic BUR R-5 Existing asphaltic BUR Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, DensDeck or Invinsa Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, DensDeck or Invinsa or min. 1.5-inch Invinsa Foam JM UIA (Optional) Min. 0.25- inch DensDeck or Invinsa JM UIA JM UIA N/A N/A JM UIA TWO- (Optional) Additional layers of base insulation DensDeck or Invinsa or min. 1.5-inch Invinsa Foam JM UIA TWO- N/A N/A TWO- 45, 60, TPO 45, 60, TPO 45, 60, TPO 45, 60, TPO 45,, JM TPO MA-SB, JM TPO MA-SB MA-SB, MA-LVOC, JM TPO MA-SB, MA-SB -75.0 A 1/2-75.0 A 3/4 A ½ -157.5 A 3/4-105.0 A 3/4-105.0 A 3/4 Page 29 of 34