Simple, intuitive and accessible MRI solution for preclinical research. M-Series Compact MRI Systems

Similar documents
Simple, intuitive and accessible MRI solution for preclinical research. M-Series Compact MRI Systems

Powerful MRI, Simplified. Innovation with Integrity. ICON, compact MRI system. Compact MRI

Insight Through In Vivo Imaging

Vevo The Ultimate Preclinical Imaging Experience

Vevo The Ultimate Preclinical Imaging Experience

ClinScan. think forward. Small Animal MRI Solution for Molecular Imaging and Translational Research. Preclinical MRI

NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING

Imaging INNOVATION. Innovative Technology For Preclinical Imaging. Powerful Yet Simple To Use

BME101 Introduction to Biomedical Engineering Medical Imaging Özlem BİRGÜL Ankara University Department of Biomedical Engineering

Preclinical MRI. Solutions for Small Animal Imaging. Molecular Imaging

The Unique, New MRI Philips Ingenia 3 Tesla is now in Ayios Therissos! The first-ever digital broadband MR system has been installed in Ayios

NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING

The first MR with IQ Philips Intera 1.5T With SmartExam

GE Healthcare. PET/CT + MR Trimodality Imaging

Visualizing the invisible

NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING

Advanced preclinical optical imaging. Preclinical in vivo imaging. IVIS Spectrum

High-Throughput In Vivo Bioluminescence Imaging System

Imaging INNOVATION. Innovative Technology For Preclinical Imaging. Powerful Yet Simple To Use

Balancing versatility and value Introducing Optima MR T

Raising the Bar in Preclinical Imaging

OUR WISH LIST RESEARCH EQUIPMENT

OUR WISH LIST RESEARCH EQUIPMENT

Final Project

Principles of translational medicine: imaging, biomarker imaging, theranostics

Vantage Titan 1.5T MR. The Intelligent Choice.

Background. Magnetic Resonance Spectroscopy (MRS) non invasively measures metabolite concentrations

MB3600. Versatile FT-NIR analyzer designed for your industry. The most reliable FT-NIR specifically designed for QA / QC.

Mirada Case Study. VentureFest, July

Translational Multimodality Optical Imaging

LOGIQ S8 with XDclear Simply Amazing

Quantitative Imaging Biomarker DCE - MRI

Photoacoustic imaging of vascular networks in transgenic mice

CapitalBio LuxScan TM. HT24 High Throughput Microarray Scanner. Exploit the full capacity of your lab

NEW INSIGHTS. NEW DISCOVERIES. Real-time automated measurements of cell health, movement and function inside your incubator.

NovaWAVE. A new category of Automated Microwave Digestion

surface metrology. As the world s leader in precise, noncontact, 3-D surface metrology, Zygo has continually

APPENDIX I Working Group 1

Guide to the DSI System Transmitters, Receivers & Dataquest Acquisition System

Simplify your pathogen testing. Amplify your confidence.

Preclinical in vivo Imaging. Innovation with Integrity. Preclinical Imaging. Nine modalities - Unlimited research capabilities

Prof. Steven S. Saliterman

Simplicity is efficiency. Analyzing Moisture Content by Using Magnetic Resonance Technology

Artifacts Caused by Eddy Current in Diffusion MRI

Gastrointestinal Motility Monitoring

Inoculation efficiency is the first step in the bacteriology testing process and is the first opportunity for automation.

UNC s Biomedical Imaging Research Center (BRIC) Roger Sit, Ph.D., CHP NCHPS Spring 2013 Meeting February 28, 2013

CQIE MRI PROCEDURES. American College of Radiology Clinical Research Center. Centers for Quantitative Imaging Excellence LEARNING MODULE

Introducing a new take on efficient workflow: Deeply integrated clinical applications

your standard Making high performance Powered by ostream Multiva 1.5T MR systems This material is not for distribution in the USA.

NEW INSIGHTS. NEW DISCOVERIES. Real-time automated measurements of cell health, movement and function inside your incubator.

QuasIR 3000 Integrating Sphere FT-NIR. A New Generation of FT-NIR Analyzers

Philips Solutions for Critical Access Hospitals. simple. affordable. reliable.

SELF-REGULATORY INITIATIVE FOR MEDICAL IMAGING EQUIPMENT MAGNETIC RESONANCE MEASUREMENT OF ENERGY CONSUMPTION

Trusted Performance. Smart Investment. 80 detector row Ultra Helical CT

Family IMAGING FOR SCIENCE. nanoscan products are the first in the following:

Edinburgh Imaging Academy online distance learning courses. Preclinical Imaging

Family IMAGING FOR SCIENCE. nanoscan products are No.1 in the following:

Diagnostic Medical Image Processing

Ingenia MR-RT. MR Systems. The comprehensive MR-sim solution to fit your planning

Preclinical In Vivo Imaging Solutions

Press Presse Press Presse

Table-Top CR Imaging Solution

Positron Emission Tomography Present status and future prospects

Uncompromised accuracy in neuroimaging and treatment

Considerations When Setting Up a Preclinical In Vivo Imaging Laboratory

Our family of products keeps your family safe.

Meet your new business partner. MAGNETOM ESSENZA. Answers for life.

Advanced visualization for real-time radiology. IntelliSpace Portal

Leksell. Vantage Stereotactic System. Advancing stereotactic neurosurgery

New PET/CT from Siemens helps more patients benefit from premium technologies

background digitalization

GE Healthcare. Introducing Brivo MR T. Bringing high-field MR. within reach

C-arm CT with SIREMOBIL Iso-C 3D A New Dimension of Care in the OR

Translational & Molecular Imaging Institute

Project Status Update. P09701 Corning Tropel LightGage Metrology System

Arterial Spin Labeling (ASL)

Pre-clinical and postmortem diffusion MRI

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

MRI CryoProbe. "c_ MAl. Innovation with lntegri~ Unrivaled Sensitivity in Preclinical MRI

CARESTREAM RIS/PACS SuperPACS Architecture. A Changing Landscape

PinAAcle 500. Flame Atomic Absorption Spectrometer

Leap Into Future In Image Navigation Neurosurgery: Visit to the BrainSuite at King Fahad Medical City in Riyadh, KSA

BIOMEDICAL ENGINEERING (BME)

Fluent for Genomic Workflows INCREASED PRODUCTIVITY POWERED BY TECAN S AUTOMATION WORKSTATION

Overview: Unmet Need: 1 Cell Sense: Enabling in vivo cell tracking

Integrated planning, navigation and robotic targeting for tumor ablation

Advantages and challenges of whole-body MR-PET. Gaspar Delso Axel Martinez-Möller Stephan Nekolla Sibylle Ziegler

Section: Magnetic Resonance Imaging

CareCenter MD The first PC-based, wireless, diagnostic workstation

Images as Biomarkers potential future advances in the field as viewed by ISPY-2. Nola Hylton, PhD University of California, San Francisco

Thermo Scientific Nicolet is20 FTIR Spectrometer

DCE MRI Team Activity. Gudrun Zahlmann, Edward Jackson, Sandeep Gupta

Product Brief: VevoCQ Advanced Contrast Quantification Software Analysis Tools for the Vevo 2100 System

Streamline workflow for higher productivity and patient throughput. DirectView. Classic CR System

Delivering top performance. Outstanding value. Diagnostic scalability. ACUSON X150 Ultrasound System.

Award Number: W81XWH TITLE: Magnetic Resonance Characterization of Axonal Response to Spinal Cord Injury

Molecular imaging in vitro and in vivo

Transcription:

Simple, intuitive and accessible MRI solution for preclinical research M-Series Compact MRI Systems

Application Oriented Imaging Anatomy and Morphology In vivo soft tissue imaging for morphological characterization. 2D and 3D imaging can be performed quickly and easily for preclinical model assessment. Cancer Research Detection, follow-up, and quantification of tumor development and progression. Ex vivo Imaging High-resolution, high throughput, 3D MR-based histology imaging of fixed samples and embryos for toxicological and developmental studies. 2

Molecular Imaging Using Contrast Agents Detection and quantification of cellular activity targeted and enhanced with contrast agents Neurobiology In vivo anatomical imaging of the brain, spine and spinal cord for assessment and follow-up of neurologically-based diseases Multi-modality Imaging Easy registration with other modalities such as Optical, PET, SPECT and CT to enable powerful multi-modality pheno-typing. 3

Simplified and Optimized Preclinical Research Aspect Imaging is the world's leader in compact, high-performance MRI systems: Powerful results without the cost, complexity and technical burden of conventional MRI systems. With the M-Series TM platform, academic researchers and pharmaceutical companies can harness the power and insights of MRI, deriving quantified answers to their biological questions - quickly, easily and cost effectively. 4

M-Series : Compact MR Imaging Non-invasive 3D anatomical, functional and molecular results in mice and rats Simple to operate Intuitive software interface and analysis tools require no prior experience in MR imaging to fully execute the workflow and imaging. No additional infrastructure necessary to maintain the magnetic field Aspect's permanent magnet technology removes the need for cryogens, plumbing, chemicals and supplemental power supplies or coolers. Pain-free installation, ready for imaging from day one Simply wheeled into position and moved around based on the needs of the working lab, with imaging possible just a few hours after installation. No running cost of upkeep Negligible running cost with a maintenance free magnet, no moving parts or cooling. Standard warranty is 12 months with options for extended warranty for up to 5 years. Power fluctuations and outages have no impact on the permanent magnet. No dedicated housing facilities Requires no dedicated power supply, no shielding, isolation from other metal objects or other magnetic field restrictions. Height 1080 mm Height 1320 mm 734 mm Depth 950 mm Width 790 mm 5

M3 : For Mice and Small Animal Imaging M7 : From Small Mice to Large Rats Aspect's MRI systems offer a comprehensive preclinical solution to quantify the expression of disease, monitor disease progression and assess therapeutic efficacy and response in lab rodents. The smaller sized M3 makes the power of MRI systems available to the significant portion of academic researchers requiring only mice imaging. The larger-scale M7 delivers imaging for both mice and rats. High performance, compact, permanent magnet on a portable cart Integrated mini electronics cabinet PC workstation with simple and intuitive operating software Scalable with easy magnet only upgrade. Workstation, software and electronics are the same for all M-Series compact MRI systems Flexibility and customization available for more advanced MRI users A complete solution including animal handling, physiology monitoring and anesthesia delivery Best-in-class post processing, analysis and data management solution 6

M-Series Imaging Software Platform Acquisition software for preclinical MR imaging, integrating a coherent suite of sequences: Spin echo with the following options: Respiration/cardiac triggering Preceding inversion recovery pulse Diffusion weighted imaging Gradient echo with the following options: 2D and 3D Respiration/cardiac triggering Dynamic acquisition i.e. Dynamic Contrast Enhanced (DCE) IR Snap for T1 map generation Fast spin echo 2D and 3D Respiration/cardiac triggering Variable echo train length Multi-point fat/water separation Extensive post-processing tool - VivoQuant Image Analysis and Co-registration Software - includes: 3D ROI segmentation tools with automatic, semi-automatic and manual segmentation Co-registration tools to generate multi-modality MR images (automated, manual and fiducially-aided), e.g. PET/MR Supports multiple input data formats, and multiple output formats including video loop generation Modeling tools to generate T1, T2, and ADC maps Co-registration capabilities with optical and PET imaging 7

Optimized Animal Handling System A full suite of application-specific RF coils and animal handling beds and accessories: Type Dimensions Inner Diameter Length Application Mouse head 23 mm 25 mm Neurological imaging in mice Mouse body 30 mm 50 mm Extremity, abdominal and thoracic cavity imaging in mice Mouse whole body 30 mm 80 mm Whole body imaging in mice LumiQuant - mouse body 38 mm 50 mm Multi-modal imaging in mice Obesity studies in mice Rat head 35 mm 40 mm Neurological imaging in rats Rat body 50/60 ellipsoid 90 mm Extremity, abdominal and thoracic cavity imaging in rats Large rat body 71 mm 90 mm Extremity, abdominal and thoracic cavity imaging in large rats MR-based Histology Module Automated multi-sample ex vivo imaging Accommodate long scan times (>1 hr) for high spatial resolution Easy to use multi-sample ID and data management system Multi-nuclear Capabilities Optional imaging coils for advanced multi-nuclear imaging Supports imaging and detection of 13 C, Xe and F Multi-modality Capabilities Simultaneous PET/MRI with SimPET (MR compatible PET insert from Brightonix Imaging). MIM (Multimodal Imaging Module) for MRI and optical co-registration (3D Bioluminescence by IVIS SpectrumCT) 8

Fully Integrated Animal Handling System Facilitating a complete setup for preclinical imaging with designated coil for different imaging applications Motorized calibration mechanism enabling automatic coil-tuning Water heated animal bed maintaining hydrated body temperature Physiological monitoring system (respiration, ECG and temperature) Delivery and evacuation of isoflurane-based anesthesia Small animal physiological monitoring Respiration, ECG and temperature monitoring Respiration and ECG output triggering to MRI spectrometer Additional readouts monitor Isoflurane-based anesthesia Vaporizer with temperature and flow-rate compensation Scavenging cube for waste gas Breathing circuit with 3 access points 9

Taking notes 10

DOC10001019 Rev.3 Product specification and descriptions in this document are subject to change without notice. Aspect Imaging 2016. Made with recycled paper. info@aspectimaging.com www.aspectimaging.com