Aseptic Processing Current Issues & Trends

Similar documents
Overview and Introduction Annex 1 Revision

On behalf of the PHSS Pharmaceutical and Healthcare Sciences Society (UK).

Points to Consider for Aseptic Processing Part 2 May 2016

How to Handle Excursions in Environmental Monitoring (EM) and Personnel Monitoring (PM) in an Aseptic Processing Plant

EU GMP ANNEX 1 CHANGES CLARIFICATION AND IMPACT

FDA s Guidance for Industry

STERILE FILTRATION: PDA: A Global. Clarification Proposal Annex 1 Paragraph 113:

Is it true, Annex 1 revision will have no impact on resources or cost? Walid El Azab Technical Service Manager STERIS

HVAC and Risk Management RACI Meeting 7 th December Agenda. Design. Project Management. Context. Qualification. Construction

Complaints Investigations Root Cause Analysis

INSPECTOR S OBSERVATIONS AND WARNING LETTER

Contamination Risk Assessment in Aseptic, Non-Sterile and Terminally Sterilized Products March 7 th & 8 th Raleigh, NC

Sterilizing and Bioburden Filter Risk Assessment in Vaccine Processes as part of QRM

Environmental Monitoring of Aseptic Processing Areas - 2

Aseptic Process Validation

Annex A2. Guidance on Process Validation Scheme for Aseptically Processed Products

Preparing Your Aseptic Processing Facility for an FDA Inspection. Valerie Welter, Director Quality Bayer HealthCare March 10, 2014

Supplementary Training Modules on Good Manufacturing Practice. Validation. WHO Technical Report Series, No. 937, Annex 4.

Review Validation of aseptic processes for pharmaceuticals

Overview of a sterility assurance program for PET drugs

PDA: A Global. Association. Matrix Approach to Media Fills. (c) 2012 Catalent Pharma Solutions. All rights reserved.

Media Fill A Process Simution. Presented By Shikha Chauhan

ANNEX 1: COMMENT SUBMISSION DOCUMENT

Environmental Monitoring of Aseptic Processing Areas - 1

Aseptic Processing Practices and Process Validation of Aseptic Operators

Change Control Overview

Hot Topics in Drug Product Process Validation: A Reviewer s Perspective

PROCESS VALIDATION ROCHAPON WACHAROTAYANKUN, PH.D.

Whitepaper. High temperature HEPA filtration. Dr.-Ing. Marc Schmidt, Dr.-Ing. Lothar Gail, Hugo Hemel MSc. Preview

A Journey in Global PUPSIT Implementation with Benchmarking. PDA Midwest Event Oct 5th, 2017 Jeff Gaerke P.E.

Environmental Control Requirements. Gordon Farquharson July 2017

EUROPEAN COMMISSION HEALTH AND CONSUMERS DIRECTORATE-GENERAL

EU Guidance / Q&A. Greg McGurk, GMP Manager (acting) GMP Conference. 7 February 2017 Dublin

Microbiological Consideration for Non-Sterile Pharmaceutical

BFS IOA BFS Training 2018 Kunming Qualification and Validation of a BFS-Installation including CIP/SIP

Validation Needs for Sterilization by Aseptic Filtration

GMP Inspection Deficiencies Review of Deficiencies Observed in 2013.

Whitepaper HVAC Pre-filtration

The Guidance for Industry Manufacture of Sterile Pharmaceutical Products by Aseptic Processing - (Revised version)

PhEn-602 Notes # 4 J. Manfredi

FZ LABORATORY SERVICES

Compounding Aseptic Isolators (CAI) James T Wagner

EU GMP ANNEX 1 DRAFT CLARIFICATION AND IMPACT

Good Manufacturing Practice for ATMPs Rocio Salvador Roldan DG SANTE, Unit B5

Application of Quality Risk Management Tools for Cell Therapy Manufacturing

Tests to Support Sterility Claim. Imtiaz Ahmed

Monday 8 th July Symposium 1 - Environmental Monitoring of Production Areas

GMP for ATMPs. Ian Rees, Unit Manager Inspectorate Strategy & Innovation 4 th October 2018

T H E P R O P O S A L F O R T H E Y E A R

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

EUROPEAN COMMISSION HEALTH AND CONSUMERS DIRECTORATE-GENERAL. This document is for consultation until 11 December 2015

Best Practice in Environmental Monitoring

Packaging Operations Technical Subcommittee

Guidance. Media Fills for Validation of Aseptic Preparations for Positron Emission Tomography (PET) Drugs DRAFT GUIDANCE

Validation Study on How to Avoid Microbial Contamination during Pharmaceutical Production

PDA: A Global. Association. Contamination Control: Particles, Bio-contamination, Aseptic manufacturing. PDA Parenteral 2014 Munich Conference

USP Chapter 823 USP 32 (old) vs. USP 35 (new)

Getting it Right Microbial Quality Risk Management

Validation of Sterilizing Grade Filters

This compilation of the complex

Overview of Inspection Issues with Legacy Products

Purpose of GMP. The Underlying Principle. Why Media Fill? :Session 2: Qualification/validation of aseptic techniques dos and don ts 7/5/2014

Introduction and Background

INTERNATIONAL STANDARDS ON FLUID PREPARATION FOR CONVECTIVE THERAPIES. Richard A. Ward, Ph.D.

Julie Roberts. Audit hot Topics and Regulatory Requirements

Proposed Revision of USP General Chapter Radiopharmaceuticals for Positron Emission Tomography Compounding <823>

Webinar. The New EU-GMP Annex 1 draft Dupont. GOP-Innovations your Partner for Practical Training and e-learning. 8 June 2018

Trinity College Dublin QP Forum 2017 Tuesday 25 th April

PERFORMANCE QUALIFICATION PROTOCOL HVAC SYSTEM

Good Manufacturing Practice for Advanced Therapy Medicinal Products

Contact details: Anna Silvani

Solutions for All Your Aseptic Parenteral Drug Formulation/Filling Needs. BUBBLE-FREE FILLING : A New Option in Prefilled Syringe Filling

Connecting People, Science and Regulation

Biological contamination events in isolators: What lessons can be learned?


Sterile Compounding elearning Course Curriculum 28 lessons with 33 hours of CE. Fundamentals of Sterile Compounding (8 lessons/8 hours CE)

Industry Perspective on PET Manufacturing Comparison of EU and US

Draft agreed by Quality Working Party 7 June Adopted by CHMP for release for consultation 28 June 2018

Robert Westney, M.S., RAC, CMQ/OE Director of Quality and Operations Cryologics, Inc. March 7, 2017

Single-Use Final Fill: Benefits and Considerations

MINIMUM REQUIREMENTS FOR A VENDOR

GMP - Annex 1 beabsichtige Ă„nderungen

White Paper. Risk Management in Environmental Monitoring: Should you be spotting it sooner?

LUNCH AND LEARN. September 11, CE Activity Information & Accreditation

PHCT 401 Aseptic Processes & Techniques

Current Topics For Sterile Generic Drug Products

Overview of Inspection Issues with Legacy Products. Barbara Breithaupt Consumer Safety Officer

MASTER PLANNING FOR VALIDATION

USP <1116> and Contamination

Why Do I Test, What Do I Test & When Do I Test It? Ross Caputo, PhD Chief Technical Officer Eagle Analytical Services

The ABCs and Challenges of GMP The American Experience

Residue removal in Cleanroom Environments

CERTIFICATION REPORTS, WHAT DO I NEED TO KNOW?

HISTORY AND MILESTONES

DATA INTEGRITY ASSURANCE AS KEY FACTOR FOR SURVIVING CORPORATE AUDITS AND REGULATORY INSECTIONS

Good Manufacturing Practices Purpose and Principles of GMP. Tony Gould

QUALITY ASSURANCE & AUDIT

Why change is inevitable in aseptic manufacturing?

USP CHAPTER <797> INTRODUCTION RISK LEVELS

Transcription:

Aseptic Processing Current Issues & Trends 1

Introduction Richard M. Johnson Member, PDA for 20+ years President & CEO since 2009 Ladies and Gentlemen, I am happy to be here with you. Senhoras e Senhores, estou feliz por estar aqui com vocês. Señoras y señores, estoy feliz de estar aquí con ustedes. Signore e Signori, io sono felice di essere qui con voi. 2

Products using Aseptic Technology 3

Hot Topics in Aseptic Manufacturing 4

Advent of Biologics Top 10 Global Drug Products As more Biologics are developed, they are becoming a bigger part of the dominant products. Currently, all biologic drug products are produced by aseptic processing 5

Advent of Combination Products Drivers for Combination Products Prefilled Syringes to reduce medication errors and risk of contamination in healthcare setting. An explosion of new therapies that are self administered Drug or Biologic in an Auto injector. Development of drug/device combinations, e.g. drug eluting stents. All of these involve aseptic processing 6

CURRENT ISSUES ASEPTIC PROCESSING 7

EU and PIC/s GMP Annex 1 Concept paper (EMA/INS/GMP/735037/2014) recommending the revision of the current Annex 1 developed by EMA and PIC/S combined working group and released on 5 February 2015 for public consultation (deadline for comments was 31 March 2015). Current Annex 1 is being reviewed to reflect changes in regulatory and manufacturing environments. New guideline should clarify how manufacturers can take advantage of new possibilities deriving from application of enhanced process understanding by using innovative tools as described in ICH Q9 and Q10. The revision of annex 1 should also take into account related changes in other GMP chapters and annexes as well as in other regulatory documents. The revised guideline will seek to remove ambiguity and inconsistencies and will take account of advances in technologies. 8

EU and PIC/s GMP Annex 1 (cont.) EMA -PIC/S Proposed timetable: Preparation of draft concept paper - September 2014 Approval of draft concept paper - October 2014 Released for consultation February 2015 Deadline for comments March 2015 Discussion in PIC/S Committee May 2015 Discussion in GMDP IWG - June 2015 Discussion with other Working Parties - June 2015 September 2015 Proposed date for release of draft guideline Q 2 2017??? Deadline for comments - 3 months after publication Re-discussion in GMDP IWG Q3, 4 2017 Re-discussion in PIC/S Committee Q3, 4 2017 9

Available now at the PDA on-line Bookstore 10

Examples of Hot Topics Airflow Velocity Measurements 5μM Total (non-viable) particulate monitoring Incubation temperatures for EM Incubation temperatures for media fills Duration of media fills Process simulation acceptance criteria PUPSIT 11

PDA PtC: Airflow Velocity Measurements Problem Statement Airflow velocity of 0.45 m/s ± 20% at the working surface in a critical filling zone? Recommendation Airflow patterns should be sufficient to protect exposed product, product contact packaging components, and product contact surfaces Importance of unidirectional flow Linear air velocity of 0.45 meters/sec ± 20 % measured 15 30cm from the filter face commonly recommended range to establish unidirectional air flow, NOTE: Current EU Annex 1 states 0.36-0.54 m/s as a guidance value, at the working position. 12

PDA PtC: Airflow Velocity Measurements Rationale for Recommendation Unidirectional flow is intended to allow the air to flow smoothly past and around potential obstacles with minimal turbulence and no induction of potential contamination from outside the zone. Supply air velocity should be correlated to air flow visualization studies (i.e., smoke studies ) and optimized to ensure airflow patterns that protect exposed product, product contact packaging components, and product contact surfaces from airborne contamination at the working level. This may be lower (or even higher) than the recommended accepted range. 13

PDA PtC: 0.5µm and 5µm Total Particle Monitoring Problem Statement: Should limits be applied for 5 µm particle monitoring for Grade A environments *? Recommendation Limits should not be applied for 5 µm particle monitoring for Grade A environments**. Where companies separately count particles 5 µm, they should focus on the overall trend rather than individual numbers, based on the low accuracy of the measurement. Notes: *Quantification of 5 µm particle monitoring for Grade A in addition to 0.5 µm particles is currently required by some regulatory agencies, including in EU. ** The same recommendation should apply for Grade B environments in nonoperational (as built/at rest) conditions (ISO Class 5). 14

PDA PtC: 0.5µm and 5µm Total Particle Monitoring Rationale for Recommendation Draft International Standard ISO14644-1.2 (2014) Cleanrooms and Associated Controlled Environments: Part 1 - Classification of Air Cleanliness by Particle Concentration concerning the Class 5, states that: "Sampling and statistical limitations for particles in low concentration make classification inappropriate." and "Sample collection limitations for both particles in low concentration and particles greater than 1 micrometer make classification of this particle size inappropriate, due to potential particles losses in the sampling system." Monitoring of particles 0.5µm (which includes particles 5 µm) is adequate for Grade A environments. 15

Incubation temperatures for EM Problem Statement: What incubation conditions are scientifically appropriate for environmental monitoring samples? Recommendation Mesophilic incubation conditions (within 20 o C to 35 o C ± 2.5 o C, 3-7 days) recover microorganisms from ambient-temperature environments Yeast and mold detection improved by the use of specialized recovery media, nonselective media (SCDA) usually suitable for total aerobic counts Assess media and incubation regimen to ensure sufficient for intended purpose Recovery of yeast and mold may be hampered by higher temperatures (above 30 o C) 16

Incubation temperatures for EM Rationale for Recommendation There is no universal set of incubation conditions for all EM isolates Defined conditions should permit microbial shifts occurring within the manufacturing environment Assessment of regimen assures adequacy to evaluate risk posed by any unique conditions 17

Incubation temperatures for media fills Problem Statement: What are suitable incubation temperatures for process simulations? Recommendation 1. Incubation conditions should be suitable for recovery of all potential microbial contamination. 2. Generally, incubation conditions should be not less than 14 days at a temperature range between 20-35 o C. 3. Should provide scientific rationale for selection of incubation conditions including temperature. Literature, data or growth promotion tests of environmental isolates may be used to support temperature range. 4. Growth promoting tests should be performed to confirm the suitability of the incubation temperatures and conditions. This may involve multiple temperatures. 5. Where multiple temperatures are used, sequence and duration of temperature incubation should be justified. 18

Incubation temperatures for media fills Rationale for Recommendation Temperature conditions should be selected based on the knowledge of the characteristics of potential contaminants and process conditions. Most mesophilic environmental contaminants will grow at any temperature within the range of 20-35 o C over 14 days. Lack of definitive scientific data to support use of multiple temperatures. 19

Duration of media fills Problem Statement: What is the appropriate duration of an aseptic process simulation run? How should process simulation address multiple shifts and campaign production runs? Recommendation 1. Sufficient to challenge complete aseptic production process. Fill number of units to ensure activities/interventions are covered (perhaps even longer than normal production) 2. Assess highest risk events permitted during routine processing, simulate conditions which provide greater likelihood of uncovering contamination 3. Consider human variability in performance, level of automation and barrier technology 4. Address multiple personnel and shifts in risk assessment (RA) 5. Batches filled over days w/o intermediate sterilization (campaigns) evaluated in risk assessment 20

Duration of media fills Recommendation (cont.) 6. Determine rationale and approaches applicable to unique operations in documented RA 7. Simulate pre-determined interventions, consider filling platform (isolators, RABS, automation, manual), other characteristics of containers and closure systems 8. RA determines number and frequency of interventions and duration related conditions/activities 9. Where there are no risk-based duration-related effects, or where longer duration does not add scientific merit, it should not be necessary for a process simulation to equal or be longer than maximum production duration 10.Manual aseptic filling or closing processes are highly dependent on operator s individual performance as the process. Therefore it is recommended that full duration media fills be used to qualify these processes. 21

Duration of media fills Rationale for Recommendation Contamination of an aseptic process is primarily a function of events rather than time. The maintenance of aseptic environmental conditions is best assessed through environmental system design and EM. Properly designed automation and barrier technology should reduce the frequency of, or risk associated with human interventions. These factors should be addressed in the risk assessment and process simulation design. Good process design including human factors assessment, adherence to first air principles, training, operations experience, monitoring, ergonomics, and the scheduling of breaks and rest periods are better tools for controlling the performance of clean room operators, operations, and the potential effects of human fatigue, than the passage of longer duration media fills. 22

Process simulation acceptance criteria Problem Statement: What are the acceptance criteria for aseptic process simulations (APS)? Recommendation The objective of the aseptic process simulation (APS) is to produce zero contaminated units, irrespective of run size. Therefore the target involving such simulations should be zero positive units. Upon discovery of any positive units, an investigation including a comprehensive risk assessment should be performed to assess any potential root causes, implementation of Corrective and Preventative Actions (CAPAs), and respective documentation. 23

Process simulation acceptance criteria Recommendation (cont.) It is critical to verify the robustness 1 of the modified process. In addition to other qualification requirements, it may be advisable to include multiple process simulation runs to verify the robustness of the implemented corrective actions with consideration of the following: (a) Potential for multiple root causes (b) Introduction of CAPAs may inherently introduce unintended consequences which are otherwise not sufficiently challenged; or may represent a departure from the original qualified state. Investigations which determine a definitive and readily identifiable root cause, might provide grounds for a reduced number of repeat run(s). However, CAPAs should be put in place to avoid such issues and deviations to studies and processes from reoccurring. In all cases, the execution of additional run(s) without the undertaking of a comprehensive risk based investigation to identify and correct any potential root causes is not acceptable. 1 Robustness in this case focused on the maintenance of sterility. 24

Process simulation acceptance criteria Rationale for Recommendation Process simulation contamination rates resulting in zero positive units should be achievable in well designed and operated production lines. The aseptic process simulation provides additional but not absolute assurance of process control on a periodic basis. While part of the overall approach to process validation, process simulation is only one of the many tools or approaches designed to evaluate the processing steps for aseptic manufacture. The necessarily high degree of control and assurance for aseptic processes relies collectively on the qualification and validation of many systems including product, equipment and component sterilization, personnel training and aseptic behavior, environmental controls, and extends to facility design, inclusive of personnel, material and equipment flows. Since these processes are inextricably linked in the overall control and assurance of asepsis, the occurrence of even a single contaminated unit in an APS, may be indicative of an underlying issue in any one of these systems and should be viewed as a significant event. 25

Process simulation acceptance criteria Rationale for Recommendation (cont.) In the event that a root cause cannot be established, the expectation is that all reasonable potential causal factors of the failure are considered and steps taken to improve any and all identified issues arising from the investigation including a comprehensive risk assessment. Any and all deficiencies identified in the investigation and risk assessment should be addressed. Note: A comprehensive investigation may conclude that the discovery of a single contaminated unit is not indicative of a failed process, consistent with local regulatory requirements. Recurring positive units in successive process simulations indicate a problem and should be investigated and resolved even when the acceptance criteria are met for each individual simulation. 26

PDA PtC: Pre-Use, Post Sterilization Integrity of Sterilizing Filters (PUPSIT) Test Problem Statement: Should a pre-use, post-sterilization integrity test of sterilizing filters be performed? Recommendation Pre-Use, Post Sterilization Integrity Testing (PUPSIT) of sterilizing grade filters as means to ensure filter integrity throughout use and product sterility should be evaluated case by case by means of comprehensive risk assessment. Risk assessment should be executed by line and by product to include side by side comparison of conducting vs. not conducting PUPSIT. NOTE: The current requirement in EU is to perform a pre-use, post-sterilization integrity test. 27

PDA PtC: PUPSIT Recommendation (cont.) The risk assessment should include risk related elements, such as: An assessment of the effect of a filter failure should one occur, including the potential introduction of non-sterile product into the aseptic area An assessment of the risk of contamination due to additional manipulations on presterilized filters (e.g.: Ready to Use) Ability to detect a potential breach Likelihood of microbial ingress to the downstream side of the filter (when PUPSIT is performed) Potential for blocking the sterilizing filters due to processing stream (particulate or bioburden) Determine if the existing production lines can be modified to add ability to perform a PUPSIT and assess the potential risk to the product or sterile boundary by implementing such modifications Determine if there is a control strategy in place for the steam sterilization process (SIP) to prevent filter damage during SIP Impact of wetting fluid on product dilution and product attributes Impact of the additional time required on time-sensitive processes 28

PDA PtC: PUPSIT Recommendation (cont.) If outcome of risk assessment indicates PUPSIT procedure reduces product quality (or business) risk, and PUPSIT procedure does not increase the overall product quality risk, then PUPSIT may be implemented. However, if risk assessment indicates PUPSIT procedure results in additional risk to product quality, then PUPSIT procedure should be avoided. 29

PDA PtC: PUPSIT Rationale for Recommendation PUPSIT may provide added insurance of a filter s integrity throughout processing and can reduce risk of product loss in case a re-filtration is not possible, and for preventing the risk to introduce contamination into aseptic area. However, implementation of such a test must be risk assessed for each process and manufacturing site as PUPSIT implementation may result in a higher risk to product contamination after sterilization due to increased downstream manipulations and/or addition of equipment into downstream process, which may not be detected afterwards. No scientific evidence (we are aware of) that non-integral filter pre-use will not be detected by a post-use integrity test. 30

CURRENT TRENDS - ASEPTIC PROCESSING 31

2016 Aseptic Mini-Survey Results 1. Nineteen questions that were hotly debated during the development of the PDA Points to Consider for Aseptic Processing 2. Results were tabulated from all four of the 2016 PDA workshops 3. A more extensive survey will be coming out from PDA later this year. Copyright 2017 PDA 32

Mini-Survey Results 1. Where are your operations located? (indicate all that apply) San Diego Berlin Dublin WDC Total Europe 16 26 53 17 112 Japan 4 2 6 8 20 Latin America 7 2 9 9 27 North America 31 10 15 34 90 Other Asia 8 7 11 13 39 2. How many aseptic filling lines does your company operate? San Diego Berlin Dublin WDC Total 0-5 23 15 29 14 81 5-15 5 4 14 16 39 25-30 2 4 4 2 12 More than 30 3 4 6 3 16 33 33

2016 Aseptic Mini-Survey Results 3. What percentage of your filling lines utilizes RABS or Isolators? 4. If you plan to purchase a new filling unit in the next year, what type are you planning to use? San Diego Berlin Dublin WDC Total 50 100% 13 17 38 10 78 25 50% 3 5 5 9 22 1 25% 7 3 4 7 21 None 9 2 5 9 25 San Diego Berlin Dublin WDC Total Located in Isolator 17 16 18 13 64 Located in RABS 7 8 2 18 35 Robotic or full automation 4 3 0 1 8 Conventional 3 0 4 3 10 Blow Fill Seal or Form Fill Seal 1 1 4 0 6 Closed Vial Filling 0 0 0 0 0 Manual Filling 2 0 0 0 2 Other 1 0 3 4 8 34 34

2016 Aseptic Mini-Survey Results 5. In what environment are your cappers located? San Diego Berlin Dublin WDC Total Grade A 17 12 31 20 80 Grade B 5 2 6 4 17 Grade C 5 4 6 6 21 Grade D with Unidirectional HEPA airflow 6 9 8 11 34 6. Do you monitor for Total Particulate in the following sizes? San Diego Berlin Dublin WDC Total 0.5 µm and 5.0 µm 30 24 50 33 137 0.5 µm only 2 1 0 3 6 It depends on whether product is manufactured for EU 2 2 0 0 4 35 35

2016 Aseptic Mini-Survey Results 7. What incubation conditions do you use for microbial Environmental Monitoring samples? San Diego Berlin Dublin WDC Total One incubation temperature o C 13 2 8 7 30 All samples are incubated at two temperatures o C and o C Some samples are incubated at o C and some at o C 15 15 34 22 86 2 8 8 4 22 Other 1 1 2 0 4 8. Who performs environmental monitoring in your operations? San Diego Berlin Dublin WDC Total QC Microbiology 30 19 36 29 114 Production 14 13 31 8 66 QA 4 4 6 1 15 Other 3 1 1 2 7 36 36

2016 Aseptic Mini-Survey Results 9. What methods of production for WFI do you employ? (indicate all that apply) San Diego Berlin Dublin WDC Total Distillation 19 25 39 29 112 Reverse Osmosis 18 7 22 15 62 Hot recirculation 16 7 15 13 51 Cold or room temp recirculation 2 0 4 3 9 Batch storage 2 1 2 2 7 Other 1 0 0 1 2 10. Does your company utilize Blow/fill/seal? If so, what environment is the BFS unit in? San Diego Berlin Dublin WDC Total Do not use BFS 34 19 36 29 118 Grade A 0 3 5 0 8 Grade B 1 1 3 0 5 Grade C 1 2 3 3 9 Grade D 1 1 0 1 3 Uncontrolled 0 0 0 0 0 37 37

2016 Aseptic Mini-Survey Results 11. What cleanliness Grade do you use for manufacturing of terminally sterilized liquid products? San Diego Berlin Dublin WDC Total We do not terminally sterilize 16 15 29 13 73 Grade A 15 7 15 10 47 Grade B 3 1 2 2 8 Grade C 7 7 6 12 32 12. What are your acceptance criteria for aseptic process simulations? (indicate all that apply) San Diego Berlin Dublin WDC Total Less than 1 in 1,000 at 95% CL 3 2 8 2 15 FDA/EMA Criteria 20 15 24 23 82 Zero Positives 12 13 22 11 58 Other 0 0 1 1 2 38 38

2016 Aseptic Mini-Survey Results 13. What incubation temperatures do you use for process simulations? San Diego Berlin Dublin WDC Total One incubation temperature oc 5 1 1 1 8 All samples are incubated at two temperatures oc and oc Some samples are incubated at oc and some at oc 14 22 45 29 110 0 1 2 0 3 Other 2 2 0 0 4 14. Do you incubate and evaluate non-integral media fill units and/or units which are otherwise procedurally deemed rejected units (during routine operations) as part of the media fill study? San Diego Berlin Dublin WDC Total Yes, startup units 1 3 3 3 10 Yes, all units 14 6 17 12 49 No 12 4 20 14 50 Yes, for some 2 14 12 4 32 39 39

2016 Aseptic Mini-Survey Results 15. Do you invert process simulation units prior to or during some or all of the incubation period? San Diego Berlin Dublin WDC Total Do not invert 7 3 5 4 19 Inverts prior to media fill 12 9 9 12 42 Incubate inverted 10 10 20 6 46 Other 3 9 4 7 23 16. Do you perform anaerobic process simulation fills? San Diego Berlin Dublin WDC Total Yes 1 X 4 3 8 No 21 X 38 24 83 Only in certain lines/situations 7 X 4 7 18 40 40

2016 Aseptic Mini-Survey Results 17. Do you have a disinfectant rotation program? San Diego Berlin Dublin WDC Total Yes 28 X 44 29 101 No 6 X 7 6 19 18. Do you integrity test 0.2µm filters used for purposes other than sterilization (e.g., prefiltration, for bioload/bioburden reduction, et. al.)? San Diego Berlin Dublin WDC Total YES 26 20 38 24 108 NO 6 6 8 9 29 Does Not Apply 3 0 3 3 9 41 41

2016 Aseptic Mini-Survey Results 19.How often do you verify sterilizing gas or vent filters for integrity? San Diego Berlin Dublin WDC Total After each cycle/use 12 9 25 12 58 Monthly 2 5 4 3 14 Every 6 months 9 6 16 9 40 Some other frequency 7 4 5 6 22 42 42

Closing Thoughts 43

Closing Thoughts Aseptically produced products are becoming more important. The technology needs to advance, despite challenges: Technical Financial Regulatory We need all stakeholders to work together 44

Contact Info: Speaker s Contact Information: Richard M. Johnson, President & CEO, PDA Johnson@pda.org 45