Stormwater Attenuation Systems Sustainable Drainage Solutions for Domestic & Commercial Applications

Similar documents
Environmental BA-BD. Envirosafe. Advanced Sewage Treatment Systems. Sustainable, Reliable, Affordable

SEPARATORS A RANGE OF FUEL/OIL SEPARATORS FOR PEACE OF MIND

Excellent Treatment

SEPARATORS A RANGE OF FUEL/OIL SEPARATORS FOR PEACE OF MIND

Separators. A Range of Fuel/Oil Separators for Peace of Mind.

Biotec 1-4 Package Sewage Treatment Plants

Sustainable, Reliable, Affordable

BioDisc BE-BL. Environmental BA-BD. High Performance Package Sewage Treatment Plants for Residential, Business & Leisure Applications

SEPTIC TANKS. Let us help! FOR THE COLLECTION SETTLEMENT OF DOMESTIC SEWAGE

Sustainable, Reliable, Affordable

Let us help! Free professional site visit with friendly support and advice. to make the right decision or call

/ /

Sustainable, Reliable, Affordable

Let us help! Free professional site visit with friendly support and advice. to make the right decision or call

Environmental. Entec Biotec. Minitec, P6, P12, P18 & P25 Sewage Treatment Plants. Sustainable, Reliable, Affordable

RAINWATER HARVESTING SYSTEMS FOR DOMESTIC APPLICATIONS

BioDisc BE-BL BA-BD. High Performance Package Sewage Treatment Plants for Residential, Business & Leisure Applications

A OF FUEL/OIL SEPARATORS FOR PEACE OF MIND

Technical Guidance. Guidance to proprietary sustainable drainage systems and components SUDS. 1 Queen Anne s Gate London SW1H 9BT

Rainwater Harvesting Systems for Domestic Applications

/ /

Pollution Control. A Range of Package Pump Systems for Residential & Commercial Developments. klargester.com

Separators Product Brochure

BIODISC. Let us help!

Environmental SAVE ON WATER BILLS MONEY. Rainwater Harvesting Systems for Domestic Applications. Sustainable, Reliable, Affordable

Refer to Chapter 3.0 (Description of Development) for a detailed site and development description.

Pollution Control BH-BL. BioDisc. High Performance Package Sewage Treatment Plants for Residential, Business & Leisure Applications. klargester.

stormwater management solutions for residential and commercial / industrial / retail applications

PUMPSTOR COMPLETE WASTE WATER AND SURFACE WATER PUMPING SOLUTIONS

Wastewater Solutions WASTEWATER SOLUTIONS

WMS. Residential Solutions from Polypipe. Water Management Solutions. for residential applications. CI/SfB (52.5) X November 2010

Paraprofessional Training Session 1

5.9 Water (Drainage, Supply, Flood Risk and Groundwater)

Klargester Pumping Stations Product Guide

RAINWATER HARVESTING SYSTEMS

RAINWATER HARVESTING SYSTEMS

WSUD On-site Detention in xprafts 2013

WMS. Ridgistorm-XL Low Flow Channel. For surface water and foul drainage applications. Uniclass L2172 EPIC B524. CI/SfB. (52.

Wastewater & Rainwater Solutions

ESS EcoCell Ecological Tank Systems

ENGINEERED SOLUTIONS. low impact development application guide

Inflow pipe. Drain. Drain

Environmental. Integrated Rainwater Harvesting Systems. Sustainable, Reliable, Affordable

The impacts of paved surfaces on urban allotments can be reduced by: limiting the area of paved surfaces

D-Raintank. Forward-Looking Rainwater Drainage. Collecting Drainage Saving

Pollution Control. Klargester Off-mains. Market Leading Off-mains Sewage Solutions. klargester.com

UNDERGROUND DRAIN, SEWER, SURFACE WATER & DUCT

Developers Guide for Surface Water Management.

Drainage Design Report. for. Residential Development. Morristown Biller, Newbridge, Co. Kildare. Job No: D1493-1

AQUATEK rainwater harvesting systems can reduce mains water consumption in the average domestic dwelling by up to 50%."

EnviroModule TM 2. modular underground tank systems. rainwater harvesting infiltration on-site detention bio-remediation filtration

Sustainable Drainage Systems (SUDS)

Surface water is the rainwater that runs off roofs, roads and paved areas into the public sewerage system.

Appendix 8.4. Site-wide Drainage Strategy

SURFACE WATER DRAINAGE STRATEGY AT LAND ADJOINING 98 MILTON ROAD, BELVEDERE, KENT, DA17 5BA

RainRetain Premium. Rainwater Harvesting. For domestic properties. Environmental Wastewater Solutions

Rainwater Harvesting. Wastewater Solutions. Water and. Use of a Natural Resource. Easy to Install.

Oil Separation Systems Product and Installation Guide

SEPTEMBER Bespoke Fabrication Systems

Presented By Mark Crawford Althon. Drainage Engineers Guide to Source Control A Sustainable Solution

Storm Water Management

THE STUDY ON INTEGRATED URBAN DRAINAGE IMPROVEMENT FOR MELAKA AND SUNGAI PETANI IN MALAYSIA FINAL REPORT

Sustainable Drainage Design Guidance

Proposed Alterations and Extension to 17 St. John's Road, Sandymount, Dublin 4

Rainwater Harvesting. for domestic properties. Environmental Wastewater Solutions

Illustrated Hard Landscape Seminars - Student Notes Copyright 1995 John Heather Rev Curriculum No. GD x 1.25hrs.

ACO QMAX SYSTEM. The most advanced drainage system of its kind. ACO Qmax

Ridgidrain NBS Specification

BIOFICIENT+ Wastewater Solutions

GROUND WATER. Practice Note # water. sensitive. urban. design \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \

demand special treatment Separator range

Foul Drainage Assessment and Surface Water Management Plan Land at Mill Lane Hawkinge CT18 7BY

Lesson W9 Wastewater and CSOs

BIOFICIENT COMMERCIAL SEWAGE TREATMENT PLANT

Klargester BioDisc Domestic Sewage Treatment Plant

Polystorm Modular Cell System. Performance Specification

WPL Diamond. Environmental Wastewater Solutions. EN approval Compact design No odours. Low visual impact Easy to install

and Green Infrastructure

Integrated Catchment Modelling

RainCell INDUSTRIAL AND COMMERCIAL RAINWATER HARVESTING SYSTEMS.

Preliminary Rainfall Runoff Management for Developments EA/Defra Report Procedure W5-074/A Summary Guidance for Developers and Engineers

Module 8 (L31 L34): Storm Water & Flood Management : Storm water management, design of drainage system, flood

demand special treatment Separator range clereflo TM bypass separator full retention separator forecourt, washdown & silt separators alarm systems

KINGSPAN KLARGESTER PRODUCT GUIDE. kingspanenviro.com/klargester. Page 00

SUSTAINABLE WATER MANAGEMENT SOLUTIONS

Klargester BioFicient+ Domestic Sewage Treatment Plant

How to carry out a percolation test

Wastewater treatment for single houses. D. O Dowd

The SuDS Manual Frequently asked questions

ENGINEERING STANDARD FOR DRAIN AND SEWER SYSTEMS OUTSIDE BUILDINGS FIRST EDITION NOVEMBER 2013

Diamond. Sewage Treatment. Small package sewage treatment plants for domestic and commercial properties

Shallow Dig Septic Tanks (EN Approved) Installation & Maintenance Guidelines

A SunCam online continuing education course. Design of Drywells. David E. Fantina, PE

The Role of Pervious Paving in Meeting the Requirements of the Auckland Unitary Plan


Highway Drainage 1- Storm Frequency and Runoff 1.1- Runoff Determination

New Retirement Home 6758 & 6766 Rocque Street Orleans, Ontario

BS8582, Code of Practice for Surface Water Management for Development Sites

Jensen Deflective Separator (JDS) Stormwater Treatment Unit

NSAF range. the conder NSAF range of package sewage treatment plants. clereflo TM NSAF demand special treatment

Transcription:

Environmental Stormwater Attenuation Systems Sustainable Drainage Solutions for Domestic & Commercial Applications Sustainable, Reliable, Affordable

Stormwater Attenuation Systems Sustainable Drainage Solutions for Domestic & Commercial Applications Managing the Stormwater Challenge As more river valleys become developed with hard surfaces (paths, roads and roofed areas) the volume of rainwater that runs off the land increases. This can have a severe effect in a watercourse where flash floods can occur downstream where the volume of water entering the system can be extremely high due to a cumulative effect of development upstream. Global warming has also had an impact on the level of rainfall, which has gradually increased over the past few decades. This has accentuated the problem of stormwater entering waterways. Flash floods along with rising sea levels have been responsible for some severe flooding in recent years. This has led to rising insurance claims and leaving some areas as blackspots where insurance against flood damage cannot be obtained. Sustainable Drainage Systems (SuDS) To address this problem, the drainage systems of towns, cities and developments have been surveyed and a policy of Sustainable Drainage Systems (SuDS) has been developed to counteract the problems being encountered. SuDS addresses issues of the quantity and quality of the water run-off from sites. Attenuation systems (tanks and rainwater harvesting systems) and separators (to remove oil contaminants from discharges) are required. To size the systems required, the flow rate from the development is calculated from rainfall records and the run-off rate for a particular type of surface, i.e. roadway, roofed area, grassed area, all of which allow surface water to run off at different rates. The design is normally based on the highest recorded rainfall in the previous 30 years, but this can vary. Most authorities limit the amount of rainfall run-off from a development to a level where the rate does not exceed the rate of discharge from a green field site (5ltrs/sec/hectare approx.) but this must be specified by the local authorities. A technical engineer should provide the design calculations for the surface water run-off in order to size a system. This should also include the flow rate allowed for discharge to a watercourse, and the required storage volume. How Does An Attenuation System Work? When the peak inflow rate in a storm exceeds the allowed discharge into the watercourse, the excess flow has to be attenuated on the site for the duration of the storm. This is then released at, or less than, the allowed discharge rate after the storm. Government Policy & Building Regulations - UK & Ireland Building Regulations Part H3 Planning Policy Statement 3 (PPS3) Planning Policy Statement 25 (PPS25) CIRIA publications: The SUDS manual (C697) and Site handbook for the construction of SUDS (C698) Greater Dublin Strategic Drainage Policy To store the excess volume and allow the correct discharge rate to go to the watercourse, a flow regulator is installed to bleed off the correct maximum flow rate. The flow regulator can be a vortex type system or a simple orifice plate system. The remainder of the water is stored either in-line or off-line, depending on the design. 2

In-line Attenuation Tanks In-line systems allow the water to back up through the tank and drain by gravity through the flow regulator. This system is normally used for installations where a fall through the system of 2.5-2.6 metres (on a sloped site) can be accommodated. In-line Orifice Tank System V.1 An orifice plate system works on the principle that the pressure created at a particular head will result in a particular flow based on the head versus hole size. This is a simple and inexpensive system. In-line Vortex Tank System V.2 A vortex flow regulator works on the principle of inducing a rotating flow around an opening at a high speed to limit the outflow of the liquid. This is the same principle that can be seen in a bath as it empties; the vortex reduces the flow from the bath even though there is a high head. 3

Off-line Attenuation Tank Off-line tank systems have the flow regulator in a separate chamber and allow the flow to build up and overspill into a storage tank, or tanks, adjacent to the chamber. Off-line Tank System V.3 (patent applied for) The storage tank is emptied using pumps which are activated when the level in the regulating chamber recedes after the storm. This system gives a shallow inlet to outlet dimension and can cater for larger flows. Separators Removing Pollutants from Surface Water Run-off Surface water drains normally discharge to a watercourse or indirectly into underground waters (groundwater) via a soakaway. Contamination of surface water by oil, chemicals or suspended solids can cause these discharges to have a serious impact on the receiving water. Separators do not provide attenuation. They are designed to be installed within surface water drainage systems to protect attenuation systems and receiving waters from pollution by oil. This may be present due to minor leaks from vehicles or plant, or from accidental spillage. Separators should be installed upstream of the attenuation system to protect it from contamination by hydrocarbons. Full range to cover flow rates from 3 ltr/s up to 130 (Bypass) and 200 ltr/s (Full Retention) Full Retention Separator - treats the full flow delivered by the drainage system Bypass Separator - fully treats all flows generated by rainfall rates up to 6.5mm/hr Class I and II designs - Class II units meet discharge to foul sewer Fully certified to EN 858-1 standards and compliant to PPG3 For further information please request a copy of the Klargester Separators brochure. 4

High Capacity Pumping Systems As the specification by Municipal Agencies has increased over the years, emergency storage requirements have become a mainstay for most applications in line with current legislation. To accommodate this, Kingspan Environmental has specifically developed a range of pumping stations which incorporate storage requirements which can be expanded to cater for most applications. Features Single tank installation up to 80m 3 (multiple tank systems available) Multiple valve chamber location and invert options Totally sealed system Factory pre-fabricated under controlled conditions to ensure consistent high quality construction Benefits Easy to install - one piece tank chamber Shallower excavation compared to concrete pumping stations For further information please request a copy of the Klargester Pumpstor24 brochure. 5

Rainwater Harvesting Systems Utilising a Free Resource from the Roof Rainwater harvesting systems take the captured water from a buildings roof area and uses it for internal non-potable applications such as toilet flushing. The system stores the water in an underground tank rather than allowing the rainfall to otherwise soak into the ground, evaporate or enter the drainage system. Rainwater Harvesting has many advantages over other forms of Attenuation by delivering a number of tangible benefits including: Commercial properties can reduce their mains water consumption by up to 85% Recycled water applications include washing, toilet flushing, irrigation, etc. Utilises buildings existing infrastructure Minimal installation requirements Rapid payback period on purchase costs on commercial sites For further information please request a copy of the KingspanWater Rainwater Harvesting brochure, or visit: www.kingspanwater.com 6

Advice & Information Selecting the Right Solution Sustainable Drainage Systems encompass much more than just installing a single product. The objective is to deal with the flow at source rather than traditional techniques that simply transfer the problem further down the drainage system. Each site should be tackled with management and control measures designed to meet many of the following objectives: Control and management of stormwater run-off Reduce the impact of urbanisation Ensure the protection and enhancement of local water quality Enhancing the natural recharge of groundwater Reusing stormwater to reduce load on local resources Natural integration to the local environment The Kingspan Environmental range of Attenuation products have been engineered not only as process solutions, but also to offer the user a modular system that incorporates the best practice in SuDS design. Glossary of Terms SuDS Sustainable drainage systems or sustainable (urban) drainage systems: a sequence of management practices and control structures designed to drain surface water in a more sustainable fashion than some conventional techniques. Attenuation: Reduction of peak flow and increased duration of a flow event. Catchment: The area contributing surface water flow to a point on a drainage or river system. Flow control device: Device to manage the movement of surface water into and out of an attenuation facility. Impermeable surface: An artificial non-porous surface that generates a surface water run-off after rainfall. Infiltration device: Device designed to aid infiltration of surface water into the ground. Orifice plate: Structure with a fixed aperture to control the flow of water. Permeable surface: Surface formed of material that is impervious to water but with voids in the surface which allows infiltration of water to the sub-base, e.g. concrete block paving. Pervious surface: Surface that allows inflow of surface water into the underlying construction or soil. What Information is Required to Specify the System? To specify the correct Attenuation Tank system the following information should be attained from the client or his representative: Peak inflow rate: l/sec Attenuated outflow rate: l/sec Attenuated storage volume required: m 3 Inlet pipework diameter: Proposed invert level of inlet pipe: Proposed invert level of outlet pipe: mm m m Pumping stations: A pump station is a chamber with electrical pumps installed. They are designed simply to move a body of water uphill or over a long distance where gravity is insufficient to provide the required flow rate. Rainwater harvesting: Process to collect rainwater where it falls, e.g. roofs, rather than allowing it to drain away. Soakaway: Subsurface structure into which surface water flows to allow infiltration into the ground. Source control: Control of run-off at or near its source, e.g. rainfall on a car park. Suspended solids (SS): Undissolved particles in a liquid. Vortex flow control: The induction of a spiral/vortex flow of water in a chamber to control or restrict the flow. Area available for installation: m 2 Is system under roadway/green area:... Level of water table at installation location: m 7

Kingspan Environmental Solutions Commercial Sewage Treatment Plants Large Capacity Pumping Stations Stormwater Attenuation Systems Residential & Commercial Rainwater Harvesting Oil/Water Separators Domestic Sewage Treatment Plants Packaged Pump Systems Reed Beds Domestic Rainwater Harvesting Garden Watering Systems Septic Tanks Below Ground Storage Tanks Grease & Silt Traps Packaged Drainage Systems Klargester Environmental Approved Installers Strategically located throughout the UK and Ireland, Klargester Environmental Approved Installers are appointed following a selection process which assesses their installation expertise, reputation and financial status. These performance criteria, together with their design skills and knowledge of Klargester Environmental products are also reviewed to ensure that the highest levels of professionalism are maintained. Other Applications As specialists in wastewater we are able to provide solutions for many different applications. Please contact us for further information. Kingspan Environmental Service Who better to look after your wastewater product than the people who designed and built it? Kingspan Environmental have a dedicated service division providing maintenance for wastewater and rainwater products. Factory trained engineers are available for site visits as part of a planned maintenance contract or on a one-off call out basis. To find out more about protecting your investment and ensuring peace of mind, contact us on (NI) 028 302 54077, (IRL) 048 302 54077 or visit us online at www.kingspanenvservice.com Accredited to BS EN ISO 9001: 2008 BS OHSAS 18001: 2007 Issue No. 5: August 2010 Klargester Environmental Ireland: Unit 1a, Derryboy Road, Carnbane Business Park, Newry, Co. Down BT35 6QH (NI) Tel: +44 (0) 28 302 66799 Fax: +44 (0) 28 302 60046 (IRL) Tel: 048 302 66799 Fax: 048 302 60046 email: info@klargester.ie Visit our website www.klargester.ie, or our company website www.kingspanenv.com Klargester is part of Kingspan Environmental. In keeping with Company policy of continuing research and development and in order to offer our clients the most advanced products, Kingspan Environmental reserves the right to alter specifications and drawings without prior notice. 80% Cert no. XX-XXX-000000-XX