Your partner for the right solution Project engineering of power stations Environment protection in energy sector Equipment supplying Supervision of installation of the equipment supplied Commissioning of the equipment supplied Long-term after-sale services such as maintenance, overhaul, supplying of spare parts and consumables
whb Energietechnik I 2 Table of contents 1. Company profile and philosophy Page 3 2. whb Energietechnik is specialized in Design and Engineering 5 3. Gas systems 7 4. Fuel oil systems 10 5. Boiler equipment 12 6. Air and flue gas equipment 14 7. Water systems 17 8. Steam and condensate systems 20 9. Automation 22 10. Auxiliaries 25 11. Transmission and distribution 26
1. Company profile and philosophy whb Energietechnik I 3 Head office Energietechnik GmbH founded in Bochum/Germany in 1989, provides design, engineering and project management of installations and complete systems in power projects. is committed to provide the customer with advanced technology on a high level of quality. s corporate philosophy is to make available new and better system designs to the market with special emphasis on safety, long service life and easy maintenance. has implemented its Quality Management System ISO 9001. Its quality policy applies to every step from receipt of customer enquiry through to commissioning/after sales service. This brochure is intended to give a view of several possibilities that whb can offer.
whb Energietechnik I 4
whb Energietechnik I 5 2. whb Energietechnik is specialized in Design and Engineering in accordance to european standards and ASME code requirements in the scope of: Gas systems Filtering station Pressure reducing station Flow control Metering station Safety shut-off and control valves Fuel oil systems Pumping station Heating station Flow control Metering station Safety shut-off and control valves Boiler equipment Igniters Gas and oil burners Flame control Burner valve station for control, metering and shut-off Soot blowers Air and flue gas FD and ID fans Recirculating fans Dampers Silencers Fans for cooling towers Water systems Cooling water pumps Cooling water filters Condenser ball cleaning systems Water treatment equipment Chiller Stations Magnetic filters Auxiliaries Fire fighting equipment Emergency power supply station Compressor station Hydrogen production plant Industrial closed circuit TV systems Busduct-systems including SF6 Steam and condensate Steam conditioning HP and LP By-pass system Safety valves Condenser protection Condensate pumps Injection valves Automation Control systems Control desks, cabinets and panels Transmitters, analyzers and recorders Panel mounted indicators Alarm signalling units Transmission and distribution Transformers up to 400MVA LV, MV and HV switchgears Earthing & Lightning equipment Generator circuit breaker, neutral earth cells and busducts All kinds of control and power cables
whb Energietechnik I 6 HP Gas Pressure Reducing & Metering Station Inlet/Outlet: 70/6 bar with a capacity of 2 x 110.000 nm 3 /h For a Thermal Power Station 3 x 200 MW LP Gas Pressure Reducing & Metering Station Inlet/Outlet: 6/1 bar with a capacity of 3 x 55.000 nm 3 /h For a Thermal Power Station 3 x 200MW Overall view of whole station shown above
3. Gas systems whb Energietechnik I 7 whb designs and manufactures HP and LP Gas Pressure Reducing and Metering Stations. The gas is transported normally by means of pipelines under the pressure of 70 to 80 bar. The end-user of the gas needs generally a lower pressure. An HP Reducing Station is required to reduce the gas pressure coming by pipeline, for example down to 20 bar for gas turbine applications. For most of the other applications, an HP Reducing Station is required as a first stage pressure reducing station followed by an LP station to reduce the gas pressure according to the requirements of the end-user, mostly down to less than 4 bar.
whb Energietechnik I 8 1 2 3 6 7 6 HP Gas Pressure Reducing Station Inlet: 24" ANSI 600 Outlet: 2 x DN 700 PN 10 Capacity: 2 x 110.000 nm 3 /h 7 LP Gas Pressure Reducing & Metering Station Inlet/Outlet: 17/2 bar with a capacity of 60.000 nm 3 /h For a Thermal Power Station 1 x 200 MW
whb Energietechnik I 9 4 5 1 Safety shut-off and pressure control valves 2 Gas heater 3 Safety shut-off valve 4 Auxiliary boiler for gas heating 5 Pressure control valve A typical gas reducing station is consisting of: emergency shut-off device (ESD) condensate knock-out drum filter station flow measuring heater line safety shut-off valve(s) pressure reducing valve silencer pressure relief valve(s) outlet section instrumentation control system. and following auxiliaries: condensate collecting facility N 2 -purging facility flare Venting facilities According to application, some of above facilities may not be needed. 8 whb has designed and installed several High Pressure and Low Pressure Reducing Stations according to International and German standards since more than 14 years, around the world. 9 8 Filter and heater skid with safety shutdown valves for gas turbines 9 Gas filter station for a thermal power station 1 x 200 MW 10 Manual and electrical isolation valves at gas line outlet 10
whb Energietechnik I 10 4. Fuel oil systems Fuel oil facilities from pump house till burners are one of the most important part of the power stations that use it as main or spare fuel. Fuel oil pumps, heaters, filters, flow control, metering, safety shut-off and control valves are main equipment that are subject to engineering and supply of whb. Fuel oil pumping station whb's innovative design of valve train in front of the boiler makes it possible to combine all components into a compact, factory pre-fabricated and tested station on a high quality standard, as shown on the pictures. This makes not only the installation works easy, but also the operation and maintenance. Increased safety through internal interlocks, real quick closing function (less then 1 sec.) through pneumatically actuated reliable shut-off valves are other important benefits of these stations.
whb Energietechnik I 11 Burner management station that includes oil flow measuring and metering, flow control and safety shutoff in front of the burner. Furthermore purging and atomizing steam and control air solenoid valves are also incorporated. The station is completely factory assembled, wired to a control cabinet and tested.
whb Energietechnik I 12 5. Boiler equipment whb makes engineering and supplies several boiler equipment such as: Reliable igniters and flame detector systems, Gas and oil burners for any capacity, Burner valve trains for burner management including flow control, metering and shut-off valves Soot blowers. 1 Fuel: Flame Monitoring: Flame detectors: Oil, Gas, Coal, Wood Monitoring systems designed to deliver reliable data. Monitoring quality is in no manner affected by varying operation conditions as a basis for safe and reliable plant operation. High quality flame detectors of different types are provided, depending on type of fuel and number of burners installed at the boiler monitored. 3 Gas supply line 2 Gas feed line to Igniters 1 Air feed line to Igniters 5 4
whb Energietechnik I 13 3 2 Air feed line to second boiler 6 8 7 Item Description 1 Igniter ZA 1S 2 Igniter gas control devices 3 Igniter air control devices 4 Flame detector assembly 5 Local control panel 6 Pressure control valve for igniter gas supply 7 Fans for igniter air supply, 100% each 8 Local control panel for fans Selection of spectral range Fuel Oil [nm] 190 1100 Gas [nm] 190 280 Coal [nm] 780 1800 Wood [nm] 780 1800 4 1 Combined valve station for natural gas and fuel oil 2 Natural gas valve station installed in front of the burner 3 Combined gas and fuel oil burners ready for shipment 4 Fuel oil valve station installed in front of the burner Typical schematic diagram of gas electric igniters and flame detectors
whb Energietechnik I 14 6. Air and flue gas equipment The huge amount of the air to be used for combustion of fuel shall be supplied to the furnace and the flue gas shall be exhausted to the atmosphere by means of big ventilators shown on the pictures. For the fresh air supply to the furnace, Forced Drought fans shall be installed. These fans are mostly furnished with inlet air silencers. Induced Drought fans are used to feed a part of flue gas into the furnace, for burning optimization and reducing the NO x emission. The flue gas shall be sucked from the boiler and led to the stack by means of Induced Drought axial fans. whb makes engineering and supply of all kind of fans and as well as dampers to control the airflow and shut-off the air and flue gas in ducts. The vibration control systems will be incorporated into the control system of the fans supplied by whb. 1 2 1 Control and shut-off dampers installed on an air duct 2 Forced Drought (FD) radial fan, 704.000 m 3 /h, 1800/750 kw with silencers at its double inlets 3 Induced Drought (ID) axial fan, 1.065.000 m 3 /h, 1500/675 kw 4 Recirculation ID radial fan, 308.000 m 3 /h, 1100/450 kw
whb Energietechnik I 15 3 4
whb Energietechnik I 16 Waste water M Permeate 75m 3 /h CIP CIP-Station 200m 3 /h Filtered Water Pre-filter Pre-filter RO Modules RO Modules M M Concentrate 50m 3 /h CIP Chemical Dosing Chemical Dosing Permeate 75m 3 /h
7. Water systems whb Energietechnik I 17 The water to be used to produce steam must be very clean and demineralized so that scale forming in pipes and equipment can be eliminated. Therefore it must be treated. whb s engineering and supply ranges from turn-key Water Treatment Plants (WTP) to particular systems of it, such as Reverse Osmosis Plant shown on the background. Furthermore, whb supplies all kinds of water and condensate valves and pumps for WTP plants and cooling water systems. For condenser of the plant, if it is cooled by raw water taken from a river or sea, a Condenser Ball Cleaning system is needed to eliminate the fouling and bio fouling of cooling water pipes in condensers because of different kinds of particles in cooling water, such as impurities, salts, corrosion, macro and micro organisms. whb solves this by cleaning the tubes periodically by means of sponge balls that circulates automatically. Another engineering and supply of whb is turn-key chiller stations to acclimatize the operation and control rooms. The chiller station cools down a rather big amount of water used in acclimatization of power plants that locates in high ambient temperature areas. The biggest Chiller Station whb engineered and supplied is 5 x 2 GCal turnkey plant that cools 1800 m 3 /h water from 12 C down to 6 C.
whb Energietechnik I 18 Filter Presses to dewater the solids separated from raw water Several vessels in a Water Treatment Plant (WTP) Filters in the WTP
whb Energietechnik I 19 For the power plants that has an open circuit cooling system and uses river or sea water, a Water Intake plant shall be installed. The plant shall filter the water mechanically to reduce the maximum size of impurities down to 1 mm. For this, differently sized gratings and finally fine band screens are used in line. whb s biggest supply of such Water Intake Plant was 5 x 42.500 m 3 /h plant. Grab cleaners of a Water Intake Plant with a capacity of 5 x 42.500 m 3 /h Hydraulically actuated valves in the WTP
whb Energietechnik I 20 8. Steam and condensate systems whb`s supplies for steam and condensate are: Steam Conditioning systems that controls the pressure and temperature of steam for several applications, such as; turbine by-pass, process steam conditioning, pressure relief, etc., HP an LP By-Pass Station that reduces the pressure and temperature of the steam for; cooling of reheater, cooling of final super heater, pressure control/turbine bypass, to build-up controlled pressure in the boiler, etc., LP by-pass valve Inlet: DN 400, 18 bar, 545 C Outlet: DN 700, 6 bar, 200 C Safety Valves that blow-off the steam to the atmosphere in emergency cases, Condenser Protection to protect the condenser in case of disturbance, Condensate pumps that delivers the condensate into the cycle again, Injection Valves that are used for injection of water into steam for temperature reducing.
whb Energietechnik I 21 Typical steam - water cycle of a power station HP-Bypass HP LP LP-Bypass LP-Bypass Hydraulic control units with accumulators for fail-safe function
whb Energietechnik I 22 9. Automation In a power station, there are thousands of measuring points to be able to control the temperature, pressure, flow, level, water quality, pollution of environment, etc. All these measurements are part of automation of many functional parts of systems and the whole station. Numerous references and its experience enable whb to make engineering and supply reliable equipment for controlling of systems in the form of control desks, cabinets or panels, any kind of transmitters, analyzers and recorders, alarm signalling units and vibration control systems. Typical graphic displays
whb Energietechnik I 23 Control panel of a LP gas pressure reducing station
whb Energietechnik I 24 1 2 4
10. Auxiliaries whb Energietechnik I 25 5 6 As for every plant, a power station also needs many specific auxiliary equipment such as Fire Fighting, Emergency Power Supply, Pressure air Supply, Hydrogen Production Plant, Closed Circuit TV-System, Busduct System, etc. whb has furnished several power stations with high quality auxiliaries in the past and is able to supply any auxiliary system trough its long-term experience in the field. 1 Multiple air compressor station 2 Emergency diesel power station, 1,9 MVA 3 Fire fighting pumping station 4 Air receivers, filters and oil separators 5 Visualization of furnace 6 Diesel fire fighting pump unit 3
whb Energietechnik I 26 11. Transmission and distribution For the power transmission and distribution, whb has several possibilities to furnish engineering and supply equipment, such as: Transformers up to 400 MVA LV, MV and HV switchgears Earthing and Lightning equipment Circuit breaker, neutral earth cell and busducts for generators. With its well experience, whb has supplied reliable equipment for several power stations and it is in the position to extend its scope of supply. SF6 (Sulfur Hexafluoride gas) switchgear, that minimizes space because of insulation and arc-interrupting ability of SF6 gas
whb Energietechnik I 27 Switchgear of a diesel emergency power supply set 1 2 1 Switchgear 2 Transformer
whb Energietechnik GmbH Am Vorort 14 44894 Bochum Germany Tel.: +49 234 92 235-0 Fax: +49 234 92 235-50 www.whb-energietechnik.de email : info@whb-energietechnik.de Moscow Branch: World Trade Center Mezhdunarodnaya II Entrance 6, Office 1550 Krasnopresnenskaya nab. 12 123610 Moscow Russia Tel.: +7 095 258 14 27 Fax: +7 095 258 14 20 email : whb.moscow@wtt.ru whb 05.2004/1.000