Effect of Column Discontinuity on Base Shear and Displacement of Structure

Similar documents
Seismic Response of Vertically Irregular RC Frame with Stiffness Irregularity at Fourth Floor

SEISMIC RESPONSE OF VERTICALLY IRREGULAR RC FRAME WITH MASS IRREGULARITY

PARAMETRIC STUDY ON VERTICAL IRREGULAR HIGH RISE REINFORCED CONCRETE FRAMED BUILDING

STUDY OF IRREGULAR RC FRAME BUILDINGS UNDER SEISMIC

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 09, 2014 ISSN (online):

Effect of Mass and Stiffness of Vertically Irregular RC Structure

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 07, 2016 ISSN (online):

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

SEISMIC RESPONSE OF A MID RISE RCC BUILDING WITH SOFT STOREY AT GROUND FLOOR

Analyzing Asymmetric Reinforced Concrete Frame Structures Responsiveness to Seismic Activity on Slopes Md Zainul Abedin Mudassar 1 Vinod Kumar Gama 2

ANALYTICAL STUDY ON SEISMIC RESPONSE WITH AND WITHOUT SOFT STOREYS IN MULTISTOREY RC BUILDING

Inter-Relationship between Moment Values of Columns in a Building with Different Architectural Complexities and Different Seismic Zones

Seismic Analysis of a Multi-Storeyed Building with Irregular Plan Configuration Using ETABS N. Mohan Reddy 1 Dr. E. Arunakanthi 2

Inter-Relationship between Moment Values of Columns in a Building with Different Architectural Complexities and Different Seismic Zones

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October ISSN

Seismic Analysis of Irregular Shape Building

SSRG International Journal of Civil Engineering ( SSRG IJCE ) Volume 4 Issue 6 June 2017

RESPONSE STUDY OF MULTI-STORIED BUILDINGS WITH PLAN IRREGULARITY SUBJECTED TO EARTHQUAKE AND WIND LOADS USING LINEAR STATIC ANALYSIS

Earthquake Resistant Design for Low Rise Open Ground Storey Famed Building

Seismic Performance of Multistorey Building with Soft Storey at Different Level with RC Shear Wall

Seismic Analysis of Multistoried Building

Seismic Behavior of Soft First Storey

Nonlinear seismic response of structural systems having vertical irregularities due to discontinuities in columns

Seismic analysis of vertically geometric irregular structures

Dynamic Analysis of RC Frame in Relation to the Storey Drift and Lateral Displacements, Base Shear Using Software ETABS

Miss. Sayli S Kamble. 1, Prof. Dr. D. N. Shinde 2 1 Department of civil Engineering, PVPIT Budhgaon, Shivaji university, Maharashtra, India.

Comparative Study on Seismic Behaviour of Multi Storey Building with and Without Floating Column

Comparison of Seismic Analysis of a Floating Column Building and a Normal Building

Effect of Diaphragm Openings in Multi-storeyed RC framed buildings using Pushover analysis

Analysis the Behavior of Building with Different Soft Story

SEISMIC RESPONSE ANALYSIS OF VERTICALLY IRREGULAR RC BUILDINGS USING LAMINATED RUBBER BEARING

SEISMIC ANALYSIS OF MULTISTOREY BUILDING WITH BARE FRAME, BARE FRAME WITH SLAB ELEMENT AND SOFT STOREY OF THE BUILDING USING SOFTWARE ETABS

Pushover Analysis of Structures with Plan Irregularity

[Ibrahim Khaleel*, 4(12): December, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

MODAL PUSHOVER ANALYSIS OF RC FRAME BUILDING WITH STAIRCASE AND ELEVATOR CORE

SEISMIC BEHAVIOR OF MULTI-STORY STRUCTURE WITH DIFFERENT TYPES OF SLABS

Seismic Response of RC Frame Buildings with Soft First Storeys

A Comparative Study of Seismic Response of Flat Slab Structure and Conventional RC Framed Structure

Behaviour of Tall Structure with Eccentric Loading

Seismic Analysis of Buildings Resting on Sloping Ground with Varying Number of Bays and Hill Slopes

Seismic Behavior of Multi storey Building With and Without Floating column

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 10, 2016 ISSN (online):

Research Article Volume 6 Issue No. 7

REVIEW PAPER ON COMPARATIVE STUDY OF SEISMIC ANALYSIS OF G+15 RCC BUILDING FRAMES WITH AND WITHOUT MASONRY INFILL WALLS

A Comparative Study on Non-Linear Analysis of Frame with and without Structural Wall System

Design Criteria For Reinforced Concrete Columns Under Seismic Loading

Analysis of Building with Soft Storey during Earthquake

Seismic Analysis of Flat Slab Structure

Seismic Analysis of Earthquake Resistant Multi Bay Multi Storeyed 3D - RC Frame

A Study on Seismic Analysis of High Rise Irregular Floor Plan Building with Different Position of Shear Walls

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Seismic Response of RC Framed Structures Having Plan and Vertical Irregularities with and Without Masonry Infill Action

International Journal of Advance Engineering and Research Development

STUDY ON DYNAMIC BEHAVIOUR OF HIGH RISER DUAL SYSTEM WITH IN-PLANE DISCONTINUITY IN VERTICAL ELEMENTS RESISTING LATERAL LOADS

Study on Torsional Effects of Irregular Buildings Under Seismic Loads

Modelling and Analysis of Irregular Geometrical Configured RCC Multi- Storey Building Using Shear Wall

Effects Of Vertical Geometric And Mass Irregularities In Structure

Pushover Analysis of RC Bare Frame: Performance Comparison between Ductile and Non-ductile detailing

Comparative Study of Multi-storeyed RC Building With Open Ground Storey Having Different Type Infill Walls

Effect of Soft Storey on Structural Response of High Rise Building

Comparative Study of Seismic Analysis between Conventional RC Frame and Flat Slab with Drop Muniraju K.S 1 Subramanya K.G. 2

seismic analysis of multistoried rcc building due to mass irregularity

Analysis of RC Frame Buildings Having Open Ground Storey

STUDY ON EFFECT OF OPEN GROUND STOREY ON SEISMIC PERFORMANCE OF HIGH RISE BUILDING

Pushover Analysis Of RCC Building With Soft Storey At Different Levels.

Seismic Analysis and Design of Regular and Irregular Framed Commercial Buildings

PUSHOVER ANALYSIS FOR THE RC STRUCTURES WITH DIFFERENT ECCENTRICITY

Seismic Analysis and Design of Vertically Irregular RC Building Frames

SEISMIC VULNERABILITY OF EXISTING RC BUILDINGS IN INDIA

International journal of scientific and technical research in engineering (IJSTRE) Volume 1 Issue 4 ǁ July 2016.

SEISMIC BEHAVIOUR OF RC BUILDING RESTING ON PLAIN AND SLOPING GROUND WITH BRACINGS AND SHEAR WALL

Analysis of Reinforced Concrete Building With Different Plan Shapes Resting on Sloping Ground

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 08, 2016 ISSN (online):

DYNAMIC ANALYSIS OF MULTI STOREY STRUCTURE FOR DIFFERENT SHAPES. K.Upendra Reddy 1,Dr.E.Arunakanthi 2

PERFORMANCE BASED SEISMIC ANALYSIS OF RC BUILDING USING SOFT STOREY CONSIDERATION

THE INTERNATIONAL JOURNAL OF SCIENCE & TECHNOLEDGE

Analysis of multi store symmetrical building in zone-ii on flat and sloping ground up to failure by using etabs

IS 1893 and IS Codal Changes

A Performance Based Evaluation of a Wall- Frame Structure Employing the Pushover Analysis Tool

International Journal of Advance Engineering and Research Development SEISMIC ANALYSIS ON BUILDING WITH HORIZONTAL AND VERTICAL IRREGULARITIES

PG Student, Civil Engineering Department, Saraswati College of Engineering, Kharghar, Maharashtra, India

PERFORMANCE BASED EVALUATION OF FRAMED REINFORCED CONCRETE SHEAR WALLS BY PUSHOVER ANALYSIS

Available online at ScienceDirect. Procedia Engineering 125 (2015 )

A COMPARATIVE STUDY OF OMRF & SMRF STRUCTURAL SYSTEM USING DIFFERENT SOFTWARES

Lucknow,Uttar Pradesh, India. Lucknow,Uttar Pradesh, India

A REVIEW ON ANALYSIS OF MAJOR INTERNATIONAL CODAL DESIGN PROVISIONS FOR OPEN GROUND STOREY BUILDINGS

SEISMIC ANALYSIS OF HIGH RISE BUILDING WITH IS CODE and IS CODE

EARTHQUAKE ANALYSIS OF RCC BUILDINGS ON HILLY AREAS WITH VARYING SLOPES

International Journal of Engineering Research & Science (IJOER) ISSN: [ ] [Vol-3, Issue-3, March- 2017]

Seismic Analysis of Buildings Resting on Sloping Ground and Considering Bracing System

DYNAMIC ANALYSIS OF SOFT STOREY BUILDING WITH FLAT SLAB

DESIGN AMPLIFICATION FACTOR FOR OPEN GROUND STOREY RC STRUCTURE WITH INFILL OPENINGS IN UPPER STOREYS

ENHANCING RESISTANCE CAPACITY OF SOFT STOREY BUILDING BY MEANS OF SHEARWALL INCORPORATED WITH STRUT

Seismic Performance of Combined Isolation System for Asymmetric Buildings Using Non- Linear Time History Analysis

Approximate Seismic Analysis Procedure for Multibay RC Framed Structures

Earthquake Resistant Design of Low-Rise Open Ground Storey Framed Building

Pushover Analysis of High Rise Reinforced Concrete Building with and without Infill walls

DYNAMIC RESPONSE OF MULTISTORIED BUILDING WITH AND WITHOUT IN-FILL WALLS

Effect of soft storey in a structure present in higher seismic zone areas

Transcription:

Effect of Column Discontinuity on Base Shear and Displacement of Structure Kabade P P 1, Prof.Dr. Shinde D.N. 2 1 Student M.E. Civil structure,department of Civil Engineering, PVPIT Budhgaon, Maharashtra,India 2 Associate Professor,Department of Civil Engineering, PVPIT Budhgaon, Maharashtra,India Abstract Structural engineer's greatest challenge in today s scenario is constructing seismic resistant structure. Uncertainties involved and behaviour studies are vital for all civil engineering structures. The presence of vertical irregular frame subject to devastating earthquake is matter of concern. A G+3 vertically irregular building is modeled as 3D space frame for the analysis with discontinuous column at top floor. To response parameters like base shear, storey displacement of the structure under seismic force under the linear dynamic & non linear static analysis is studied. This analysis shows focuses on the base shear carrying capacity of a structure and performance level of structure under moderate zone of India. The result remarks the conclusion that, a building structure with irregularity produced due to column discontinuity provides instability and increases storey displacement. The soft computing tool and commercial software SAP 2000 (version 15) is used for modeling and analysis. Keywords Column discontinuity; Response spectrum; Pushover analysis; Storey Displacement; Base shear I. INTRODUCTION In the past, several major earthquakes have exposed the shortcomings in buildings, which lead to damage or collapse. It has been found that regular shaped buildings perform better during earthquakes. The structural irregularities cause non-uniform load distribution in various members of a building. There have been several studies on the irregularities, viz., (Jack P. Moehle, A. M. ASCE 2002), Seismic Response of Vertically Irregular Structures, seismic response of vertically irregular frames with pushover analysis (Chintanapakdee, Chopra, 2004) and evaluation of mass, strength and stiffness limits for regular buildings specified by UBC (Valmundsson and Nau, 1997), Seismic Response of RC Frame Buildings with Soft First Storeys (Arlekar Jaswant N, Jain Sudhir K. and Murty C.V.R, 1997) etc. In the present paper, response of a four storeyed vertically irregular frame to lateral loads is studied for irregularity at top floor in the elevation. These irregularities are introduced by changing the properties of the members of the storey under consideration maintaining aspect ratio for vertically irregular frame Specified in I.S1893:2002(part1) Guidelines. Irregularity is produced by discontinuing on column at the top storey level. Effect of this column discontinuity on storey-shear forces, storey displacement at performance point is studied. II. STRUCTURAL IRREGULARITIES There are various types of irregularities in the buildings depending upon their location and scope, but mainly, they are divided into two groups plan irregularities and vertical irregularities. In the Study, the vertical irregularities are considered which are described as follows. Kabade,Shinde Page 133

TABLE I TYPES OF IRREGULARITIES Plan Irregularity Torsion irregularity Re-entrant Corners Diaphragm Discontinuity Out of plane offsets Non parallel Systems Vertical irregularity Stiffness Irregularity Mass Irregularity Vertical Geometric Irregularity In Plane discontinuity in vertical elements resisting lateral force Discontinuity in capacityweak storey III. PROBLEM STATEMENT Figure 1, 2 and 3 shows a base model frame of structure with geometrically vertical irregularities and having two bays and G+3 stories with 10 m x 10 m, with a storey height of 3.0 m for all floors and the bay width of 5.0 m. The basic specifications of the building are: Dimensions of the beam = 0.230 m 0.600 m; Column size = 0.300 m 0.600 m; Beam length = 5 m; materials used are M25, Fe415. Depth of slab 175mm; floor finish = 1kN/m 2, Imposed load 2kN/m 2 ; infill 230 mm thick, specific weight of infill and concrete are 20 kn/m 3 and 25 kn/m 3. Load combinations as per clause 6.3.1.2 of IS 1893:2002 (Part-1) are; a) 1.5 (DL+ LL) b) 1.2 (DL + LL ± EQL) c) 1.5 (DL ±EQL) d) 0.9 DL ± 1.5 EQL. In order to study the column discontinuity, two frames produced from the main frame are considered. The first frame is a regular frame in which all the columns are of full height. The second frame is irregular frame in which the middle column discontinuity is assumed to be at a top, as Figure 3 shows. Response spectrum analysis and Pushover analysis are carried out to study the effect of the column discontinuity on the behaviour of both the frames subjected to the vertical and the seismic loads. Fig 1 Plan of regular floor Kabade,Shinde Page 134

Fig 2 Plan of irregular floor Fig 3 Sectional view (P-P) Regular Frame Kabade,Shinde Page 135

Fig 4 Sectional view (P-P) Irregular Frame having discontinuity at top floor Response spectrum analysis has been carried out as per the response spectra mentioned in IS 1893(part1) 2002. For the base shear calculation and response spectrum analysis the seismic zone is assumed to be zone III, the importance factor for general building is considered, the frame is considered as special moment resisting frame. The soil type is assumed to be a medium soil. For non linear seismic analysis the hinges in the beam and column are auto generated and all the diaphragms are assumed as rigid diaphragms. Fig 5 Design Response spectrum curve as per IS 1893:2002 (Part 1) Kabade,Shinde Page 136

IV. RESULTS AND DISCUSSION SAP2000 is used to compute the response of a four (G+3) storey regular and irregular frames for rigid floor diaphragm Linear Dynamic (response spectrum analysis), Non Linear Static (Pushover analysis) Pushover curves results have been used to observe and compare the displacement of the buildings at the performance point for parabolic lateral load patterns. Following figure shows the pushover curves for both the regular and irregular frame for two orthogonal directions. Fig 6 Pushover Curve in X-direction for regular frame Fig 7 Pushover Curve in Y-direction for irregular frame Kabade,Shinde Page 137

Fig 8 Pushover Curve in X-direction for regular frame Fig 9 Pushover Curve in Y-direction for irregular frame Kabade,Shinde Page 138

V. CONCLUSIONS From the above results we can conclude the following points The base shear of regular and irregular frame in both the orthogonal direction is more than the calculated base shear. The base shear at performance point for irregular frame in X direction is reduces by 14.45% and that of in Y direction is reduced by 13.5%. The displacement in X direction at performance point is 20 mm for regular frame and that of irregular frame is 30 mm. The displacement in Y direction at performance point is 22 mm for regular frame and for irregular frame it is 11 mm The displacement of irregular frame is increased by 33.33% in X direction and that of in Y direction by 50% than regular frame. It is very clear from above values that the structural irregularity produced due to column discontinuity increases displacement but reduces the base shear under seismic loading. For irregular buildings, lesser than 40 m in height in Zones II and III, dynamic analysis, even though not mandatory, is recommended. Dynamic analysis may be performed by the Response Spectrum Method. However, in this method, the design base shear (V B ) shall be compared with a base shear (V B ) The drift in X direction for regular frame is less than the drift of irregular frame. On the other hand drift in Y direction for regular frame is more than the drift of irregular frame. The common observation is that the drift in both the orthogonal direction is suddenly increases at the discontinuous level. It is recommended that the irregularity in column is vulnerable condition for the building structure and it creates the soft storey effect. It also affects on overall performance of the building under the seismic loading. Kabade,Shinde Page 139

VI. REFERENCES [1] Jack P. Moehle, A. M. ASCE (1984), Seismic Response of Vertically Irregular Structures, ASCE Journal of Structural Engineering, Vol. 110, No. 9. [2] Valmundsson and Nau. (1997), Seismic response of buildings frames with vertical structural Irregularities, ASCE Journal of Structural Engineering, Vol. 123, No. 1, 30-41. [3] Arlekar Jaswant N, Jain Sudhir K. and Murty C.V.R, (1997), Seismic Response of RC Frame Buildings with Soft First Storeys. Proceedings of the CBRI Golden Jubilee Conference on Natural Hazards in Urban Habitat, New Delhi. [4] Chintanapakdee and Chopra. (2004), Seismic response of vertically irregular frames: response history and modal pushover analyses, ASCE Journal of Structural Engineering, Vol. 130, No. 8, 1177-1185. [5] Vinod K. Sadashiva, Gregory A. MacRae& Bruce L. Deam (2009), Determination Of Structural Irregularity Limits Mass Irregularity Example Bulletin Of The New Zealand Society For Earthquake Engineering, Vol. 42, No.4. [6] Ravikumar C M, Babu Narayan K S, Sujith B V, Venkat Reddy D (2012), Effect of Irregular Configurations on Seismic Vulnerability of RC Buildings Architecture Research 2012, 2(3): 20-26, Surathkal, India. [7] C.V.R. Murty, Earth quake tips, Indian Institute of Technology Kanpur, India Kabade,Shinde Page 140