The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications

Similar documents
Fast Detailed Hydrocarbon Analysis by Modified ASTM Method D6730

TurboMass GC/MS Software

Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools

Polymer Degradation Mechanisms using Pyrolysis- GC/MS

Analysis of an Acrylic Copolymer using Pyrolysis-GC/MS

Optimizing Productivity and Reliability for Monocyclic Aromatic Hydrocarbon Purity Analysis According to ASTM D7504 on the Agilent 8890 GC System

Clarus 600. Gas Chromatograph/Mass Spectrometers. your GC/MS results. better. faster.

SEMI-VOLATILE ORGANICS IN DRINKING WATER using EPA Method optimized for greater sensitivity

TurboMatrix Headspace and Headspace Trap Samplers

Protocol for Quantitative Determination of Residual Solvents in Cannabis Concentrates Prepared by: Amanda Rigdon, May 23 rd, 2016

CHROMATOGRAPHY/MASS SPECTROMETRY

Olefin Analyzer Solutions for Polymer Grade Ethylene and Propylene

Determination of volatile compounds in automotive interior materials by thermal desorption GC-MS

CryoTrap. For Agilent Technologies 7890/6890/6850 GC Systems. CryoTrap

Pesticide Analysis in a Complex Matrix using a 2D GC/MS System

DETERMINATION OF ORGANIC PRIORITY POLLUTANTS AND EMERGING COMPOUNDS IN WASTEWATER BY MICRO SOLID PHASE EXTRACTION COUPLED TO GCMS

Determination of Volatile Organic Compounds (VOCs) present in the interiors of car by using GCMS/MS with static and dynamic headspace

Analysis of styrene leached from polystyrene cups using GCMS coupled with Headspace (HS) sampler

Determination of Volatile Organic Compounds (VOCs) in Various Drinking Water Sources by GC/MS

Altus UPLC IT S ALL ABOUT PEAK PERFORMANCE

Improving GC-MS Method Robustness and Cycle Times Using Capillary Flow Technology and Backflushing

CLARUS SQ 8 GC/MS. Gas Chromatograph/Mass Spectrometer

EPA Method 524 for Determination of VOCs in Drinking Water Using Agilent 5975T LTM GC/MSD with Static Headspace

NATURALLY BETTER CHROMATOGRAPHY SOLUTIONS. Clarus Gas Chromatographs Clarus 680/580/480

TurboMatrix. Thermal Desorption Solutions

Gas Chromatography SSI-GC-003

Agilent Consumables Improve Performance with Shimadzu GC/MS

US EPA Method Atomx XYZ and Agilent 7890B GC/5977A MS

A Complete Solution for Aroma Characterization

Application Note. Abstract. Authors. Environmental

Gas Chromatography Assignment Chem 543/443

Clarus SQ 8 GC/MS. The NEW

Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS

The Use Of Automated Backflush on the 7890A/5975A GC-MS System. Application. Setup Example Using Biomarkers. Authors. Abstract.

1-(2-fluorophenyl)-2-(methylamino)propan-1-one

Indoor-Outdoor Volatile Organic Compounds (VOCs) Levels in Urban and Industrial Area of Dhaka City, Bangladesh. Mitali Parvin

Analysis of Semivolatiles by GC/FID using the Ultra Inert Inlet Liners with Wool

Method of determination of phthalates by gas chromatography / mass spectrometry in wines

Standard Test Methods for Aromatics in Mineral Spirits by Gas Chromatography 1

A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water

Drinking Water Semivolatiles Analysis using the 6890N/5975B inert GC/MSD. Application. Author. Abstract. Instrument Operating Parameters.

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed. Example report.

GC Troubleshooting. Frank Michel, Katherine K. Stenerson T HCE

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

Automated alternating column regeneration on the Agilent 1290 Infinity LC

Improved Performance and Productivity of Purge-and-Trap Analyses

The Use of High Resolution Accurate Mass GC/Q-TOF and Chemometrics in the Identification of Environmental Pollutants in Wastewater Effluents

Application Note: Overview. Introduction

PAMS: A Study of Performance in Low and High Humidity Environments

Improved Gas Chromatograph Method for the Analysis of Trace Hydrocarbon Impurities in 1, 3-Butadiene

A highly sensitive and robust 150 µm column to enable high-throughput proteomics

Agilent 7667A Mini Thermal Desorber MEASURE VOCS IN GAS MATRIX WHEN MOBILITY MATTERS

Chromatography Applications and Technology

The Analysis of 4-Vinyl-Cyclo-Hexene (VCH) in Butadiene with the DVLS LGI Injector

Using the Pulsed Flame Photometric Detector (PFPD) for Low-level Analysis of Organophosphorus Pesticides

High Resolution Accurate Mass Peptide Quantitation on Thermo Scientific Q Exactive Mass Spectrometers. The world leader in serving science

Improving Retention Time Precision and Chromatography of Early Eluting Peptides with Acetonitrile/Water Blends as Solvent B

Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e 1

Determination of 1,4-Dioxane in Drinking Water by Gas Chromatography/Mass Spectrometry (GC/MS) with Selected Ion Monitoring (SIM)

Capillary GC Troubleshooting: a Practical Approach

PAL SPME Fibers Optimized for Automation

MARKET FOCUSED - environmental ORGANOCHLORINE PESTICIDES

PAL SPME Fibers Optimized for Automation

Analysis of USP <467> Residual Solvents using the Agilent 7697A Headspace Sampler with the Agilent 7890B Gas Chromatograph

SCION GC Series. The Gas Chromatographers Choice for Separations

SCION GC Series. The Gas Chromatographers Choice for Separations

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC

SPECTROSCOPIC METHODS FOR VOCs DETERMINATION

Ghost Peaks in Gas Chromatography Part 2: The Injection Port

A New Horizon of Performance Agilent G1888 Network Headspace Sampler

Confirmation of THC in Oral Fluids Using High-Resolution 2-D GC/MS Application Note

Analysis of Monoclonal Antibody (mab) Using Agilent 1290 Infinity LC System Coupled to Agilent 6530 Accurate-Mass Quadrupole Time-of-Flight (Q-TOF)

The Suite for Environmental GC Analysis

SPECIFICATION. The System shall be easy to use and rugged enough to handle consistently high through performance of the activities.

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE.

MS Certified Vials. Pre-cleaned and certified vials for mass spectrometry

Using Alternative Carrier Gas for US EPA Application Note. Abstract. Introduction. Experimental-Instrument Conditions

Key Words Pesticides analysis, food safety, TSQ Endura, TraceFinder, MRL, tsrm, residue analysis

Application Note # ET-20 BioPharma Compass: A fully Automated Solution for Characterization and QC of Intact and Digested Proteins

Analysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush Application

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

US EPA Method 8260 with the Atomx XYZ and the Thermo Scientific TRACE 1310 GC and ISQ MS

for water and beverage analysis

HYDROGEN AS A CARRIER GAS. Gas Chromatography new frontiers: can Hydrogen substitute Helium?

Improving Productivity in Your Environmental and Food Testing Labs with Agilent 7890A/5975C GC/MS System

Application Note. Environmental. Agilent 1290 Infinity Binary LC. with ISET and fine-tuning. Agilent 1290 Infinity Binary LC.

Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1

Isotopic Resolution of Chromatographically Separated IdeS Subunits Using the X500B QTOF System

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

DANI A SCENT OF FUTURE HIGH PRODUCTIVITY ACCURACY AND PRECISION FLEXIBILITY AND UPGRADEABILITY USER FRIENDLY INTERFACE FAST GAS C HROMATOGRAPH

An Improved Method of Updating Retention Times for GCMS

Chemical Threat Mitigation. Innovation with Integrity. Enhanced Environmental Mass Spectrometer: Bruker E 2 M CBRNE

Meet the airgc. Ambient air carrier. Top performance. catalytics accelerated

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

SMALL SIZE BIG POTENTIAL. STA 6000 / 8000 Simultaneous Thermal Analyzers

Manual Analytical Data Adjustment. Environmental Health Laboratories A division of MAS Technology Corporation

AxION 2 TOF MS. Time-of-Flight Mass Spectrometer

performance and throughput

Tabisam Khan 1, David R. Little 1, Liyu Yang 2, Jiwen Chen 2, Parya Nouri 2, Samy Tadros 2, Patrick J. Rudewicz 2

Transcription:

TECHNICAL BRIEF Gas Chromatography/ Mass Spectrometry The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications C 14 scans Introduction As gas chromatography (GC) methods and technology evolve and provide higher resolution and throughput, the resulting analyte peaks become ever narrower. This creates a greater need for fast data acquisition in order to achieve accurate and precise representation of a chromatographic data. In addition to fast GC, high speed MS acquisition is essential in applications such as semi-volatiles in environmental samples and pesticides in food, where the MS system is required to collect different types of data simultaneously. B A 6 scans 4 scans A good practice in GC/MS is that 8 to 12 scans across a peak will give sufficient definition and reproducibility for quantitation. With slower scanning speeds, the representation of the peak may not be accurate, leading to reproducibility and quantitation problems. This is demonstrated in Figure 1. Figure 1. Consecutive 15 ng on column injections of n-decane to show the effect of scan speed on peak shape. In chromatogram A 4 scans were collected, in chromatogram B 6 scans were collected, and in chromatogram C 14 scans were collected.

The PerkinElmer Clarus 600 MS is capable of scanning at best-in-class speeds. This technical brief demonstrates the maximum scanning speeds in all three modes of MS operation: full scan, Selected Ion Recording (, also called Selected Ion Monitoring, or SIM), and SIFI (Single Ion Full Ion). In full scan mode, the maximum scan speed is 12,500 Da/sec (also referred to as amu/sec or U/sec); the speed, and more importantly, the spectral fidelity of the data produced while operating at this speed will be demonstrated in the following pages. Sample rates of up to 100 scans/sec are achievable with mode acquisition. Fast scanning capability becomes extremely beneficial when applied to SIFI functions (SIFI data acquisition is further explained in the PerkinElmer Technical note SIFI Simultaneous Collection of Full Scan and Selected Ion Recording Mass Spectral Data ). SIFI functions make use of both the fast scan and capabilities, allowing data collection with both the exceptional sensitivity of and the librarysearchable spectral data of full scan. Here, fast SIFI will be applied to a fast GC/MS analysis of aliphatic and aromatic hydrocarbons whose peak widths are 0.5 seconds wide at base, demonstrating at least 12 full spectrum scans and 12 data points across each peak. This method simultaneously achieves good chromatographic peak-shape definition, full scan library-searchable spectral data, and sensitivity. Experimental To demonstrate the fast data acquisition capabilities of the Clarus 600 GC/MS, this analysis was carried out with a very short micro bore GC column, hydrogen carrier gas, and high oven heating rates (see Table 1). The chromatographic conditions used here result in peak widths of less than one second at base. The sample used here was a mixture of n-alkanes (c-10 through c-13): toluene, ethylbenzene, m-xylene, o-xylene, and p-xylene prepared in pentane at approximately 60 ppm (μg/ml). It was necessary to use an extremely high split flow so as not to overload the column stationary phase. All three modes of GC/MS data acquisition (full scan, SIFI, and ) were evaluated. Table 2 summarizes the scanning conditions used to demonstrate the full scan capabilities; this included operating the MS at five different scanning speeds. Table 3 summarizes the mass spectrometer conditions used to acquire the high speed data, and Table 4 summarizes the conditions utilized during the testing of SIFI analysis. Table 1. The gas chromatographic conditions used through this study. Gas Chromatograph: PerkinElmer Clarus 600 Total GC Run Time: 3 min Analytical Column: Elite-1 (5 m x 0.05 mm x 0.05 μm) Injection Port Type: PSSI Injector temperature: 320 C Injection Type: Split Syringe volume: 5 μl Injection volume: 0.5 μl Injection Speed: Fast Rinse Solvent: Pentane Carrier Gas Type: Hydrogen Carrier Gas Program: 40 Psig (constant pressure) Split Flow: 400 ml/min Oven Program: Temperature Hold Time Rate 37 C 0.5 min 140 C/min 70 C 0 min 105 C/min 115 C 0 min 85 C/min 220 C 0.6 min End Table 2. Full scan mass spectrometer method conditions at each of five different data acquisition speeds. GC Inlet Line Temperature: Full Scan Full Scan range: 48-173 m/z 12,500 da/sec 6250 da/sec 0.02 sec 3125 da/sec 0.04 sec 1250 da/sec 0.1 sec 625 da/sec 0.2 sec 2

Table 3. Single ion recording mass spectrometer method conditions. GC Inlet Line Temperature: 100 scans/sec Dwell Time: Interchannel Delay: Summary of Functions: 1 ion/function Function 2: m/z 91 Function 3: m/z 57 Table 4. SIFI spectrometer method conditions. GC Inlet Line Temperature: SIFI Full Scan range: 48-173 m/z 0.02 sec Dwell Time: Interchannel Delay: Summary of Functions: 3 ions/function Function 2: m/z 91, 92, 106 Function 3: m/z 57, 71, 85 m/z 91 Figure 2. This chromatogram displays a 15 ng on-column injection of toluene, ethylbenzene, m&p-xylene, and o-xylene. C B A Figure 3. Background subtracted spectra of toluene, A was collected at 3125 /u/sec, B was collected at 6250 u/sec, C was collected at 12,500 u/sec. 3

Results In the following sections, full scan,, and SIFI, the various aspects of fast scanning will be demonstrated; data will be presented to verify that while operating at the top end speed, the Clarus 600 MS will remain precise and accurate. Full Scan The Clarus 600 MS can acquire data at speeds up to 12,500 u/sec; the ability to reach these speeds while preserving spectral integrity is demonstrated in the following tests. Figure 2 demonstrates the analysis of volatile organic compounds (VOC s) under fast GC conditions, achieving a peak width of less than 1 second. In this case, approximately 40 scans were achieved across each peak. While scanning in this mode it is necessary to show that spectral quality does not degrade over the scan speed range. To test this, multiple injections of the same standard were acquired at different scanning rates. Figure 3 depicts the spectra of toluene at 3125 u/sec, 6250 u/sec, and 12,500 u/sec. The ion ratios in Figure 3 are nearly identical across the range of scan speeds; demonstrating that spectral data remains constant across the scan range. The maximum speed of data acquisition in mode is 100 scans/sec for a single mass; this was verified with the analysis of ethylbenzene and xylenes. Figure 4 demonstrates an example of this analysis, again the peak width is less than one second and the number of scans across each peak corresponds with the expectation of 100 points per second. For example, ethylbenzene has a peak width of 0.66 seconds and 66 scans, the scans across the xylene peaks follow suit. SIFI The fast scanning capability can be combined with fast GC and SIFI acquisition to achieve high sensitivity of and full spectral data of scanning acquisition. This demonstration achieves the necessary 8-12 scans per peak desired for precise and accurate peak definition. Figure 5 demonstrates the fast SIFI analysis of c-10 to c-13 alkanes. A minimum of 10 data points were collected across each peak, with each point containing both full scan and data. This demonstrates that the electronics of the Clarus 600 MS are capable of providing sufficient speed to perform the most rigorous types of data collection under extremely fast GC conditions. Figure 4. SIM mode data collection at 100 points/sec of 15 pg on column of ethylbenzene, m&p-xylene, and o-xylene. Scan Figure 5. Full scan and chromatograms obtained from a single SIFI analysis of 15 pg on column of c-10 through c-13 alkanes. 4

Conclusion The data acquisition capability of the Clarus 600 MS allows laboratories to push their chromatograph to achieve the narrowest peaks possible, while retaining the ability to collect sufficient data for peak shape definition and quantitation. The ability to collect both and full scan data at high speeds allows outstanding flexibility in the creation of MS methods. It is used to detect low level banned pesticides in the presence of high level matrix and for quantitation of semi-volatile organics across a wide dynamic range in environmental samples. In this example, the volatile organic components toluene, ethylbenzene, and xylene were analyzed under conditions which produced peaks less than one second wide at base. The data demonstrates that sufficient scans were collected across each peak and the mass spectral data remains consistent. Additionally, fast scanning was applied to SIFI data acquisition of extremely narrow GC peaks demonstrating the Clarus 600 MS will precisely and accurately record narrow of GC peaks while collecting simultaneous full scan and data. PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/contactus Copyright 2009, PerkinElmer, Inc. All rights reserved. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 008754_01