THE SUPERIOR ROOF & WALL SYSTEMS ROOF WALL & HEADER SYSTEM

Similar documents
SIPs over a steel frame Raised SIP floor

Energy Panel Structures, Inc

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements

High Performance Walls:

High Performance Walls:

Envelope Highlights Mandatory Measures Prescriptive High Performance Walls 150.1

Introducing TJ Insulated Structural Framing Components

SIP Homes: Built for a Lifetime of Comfort and Value

Residential Construction

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

R-Matte Plus-3: Insulation for the Building Envelope

I.C.E. BLOCK (U.S. Patent No. 4,223,501) Detail Manual

GAF EnergyGuard Polyiso Wall Sheathing

Healthy, Durable, Low Energy Buildings: Thermal: High R. Thermal bridges. Fundamentals, techniques, and pitfalls

SIPs: An Engineer s Perspective

Best Barns USA Assembly Book

Carpentry. The following describes the scope and sequence of instruction for Carpentry.

Panelize Your Dreams. With Enercept, The Better Way To Build. Structural Insulated Panels The Builders Choice

Technical Data Sheet

Sentry Buildings. Assembly Book. the Richmond. 16'x32' Building w/ Full Loft. Revised February 6, 2015

Lock In Energy Savings For Life

The better way to build TM. Installation Manual NAILBASE PANELS

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

ThermaSteel Corporation ASSEMBLY MANUAL

Low-cost Construction for High-energy Savings. Brian J. Wimmer Construction Manager Rochester Area Habitat for Humanity

Integrated Air & Water Barrier Systems

ATTICS. Use: PRODEX TOTAL INSULATION Foil-Foam-Foil (FfmF), Foil-Bubble-Foil (FBF), Foil-Fiberglass-Vinyl (FfgV), Foil-Foil (FF)

Bridge to Better Building

RAY-CORE Structural Insulated Roof and Wall Panels

Table Air Barrier and Insulation Inspection Component Criteria

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

A Rater s perspective from the field. Thomas H. Marston, February 21, 2007

Chapter 14 - Air Sealing

In addition to performing as an interior vapor retarder, MemBrain the Smart Vapor Retarder may be installed as a continuous, interior

STRUCTURAL INSULATED PANEL ASSOCIATION (SIPA) Title 24 And High Performance Structural Insulated Panel Systems (SIPS)

Call for more information

Structural Insulated Panels Dispelling the Myths to Give You the Green Edge with Surprising Paybacks By Patrick Egan, Thermocore Panel Systems

Structural Insulated Panels (SIPs) Commercial, Industrial and Residential Applications

PROJECT IDEA CATALOG. FREE! Take one. Get inspired! 84LUMBER.COM

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

ROOF DETAILS RD-0 CONSTRUCTION DOCUMENTS - AGENCY/ FEBRUARY 13, 2017 MURRAY ASSOCIATES ARCHITECTS, P.C.

Lamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614)

Garage/Accessory Structures

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

7/25/2011. THERMAL BARRlERS AND IGNITION BARRIERS. What is a Thermal Barrier? Thermal Barrier Code

Durisol: Insulated Concrete Form (ICF) Wall Forming System

Wood-Framing Methods For Energy Savings

MAIN FLOOR PLAN. #G x 14 x 8 Shed - Chicken Coop By SDS-CAD Specialized Design Systems 10'-0" 3'-0" 1'-0" 14'-0" 14'-0" 1'-0" 6'-0" 3'-0"

PLYCEM SX20/20 MODULAR BUILDING INDUSTRY FLOOR SYSTEM PLYCEM SX20/20 MODULAR BUILDING INDUSTRY FLOOR SYSTEM

SECTION INJECTED or CAVITY-FILL POLYURETHANE FOAM (IPF)

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

LiveBetterLiveGreen.com. Copyright 2010 all rights reserved Live Better Live Green, Inc.

Non-Toxic Steel Roofs

assembly an open space between the roof and ceiling of a building attic balloon frame a joist constructed of steel with bars in the verticle web space

Mark Cummins 29 JAN 2018

SIPs Structural Insulated Panels System. The building technology of the future

Insulated Cold-Formed Steel Wall Panels: A case study of a contractor-manufacturer

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

ENCLOSURE: SIMPLE LAYERS

GAF Cornell ThermaCal Nail Base Roof Insulation Panels (RESGN421) Updated: 2/15

ESR-1791 Reissued December 1, 2013 This report is subject to renewal December 1, 2015.

Calculated Quantities and Details

Price, plans and specifications are subject to change without notice. Revised 01/2018

TYPICAL BEARING WALL FRAMING

The Inspection Process. Waxhaw N.C.

WE International, Inc.

The Perfect Wall Report from the field on practical external insulation strategies pros, cons, details & issues

TYPICAL BEARING WALL FRAMING Joints in plates must be offset by 24 min.

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

Price, plans, and specifications are subject to change without notice. MAPLE 2,081 SQ.FT. 3 BEDROOMS 3.5 BATHROOMS 2 STORIES

COOPERSMITH COURT. For more information, contact: Maggie Houston

COOPERSMITH COURT. For more information, contact: Maggie Houston

TULANE PLAN ,486 SQ.FT.

ESD5 GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 ROLLS HANDLING:

ESD5 GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 ROLLS HANDLING:

MEGA FIRES: The Case for Mitigation

GARAGE MAIN FLOOR PLAN

GRAND AT ALICE THE HERMANN - 1,402 SQ.FT. UNIT 1 FIRST FLOOR SECOND FLOOR FIRST FLOOR PLAN 1/4"=1'-0"

Insulation and Technologies

EXHIBIT B TO AGREEMENT BETWEEN PENSACOLA HABITAT FOR HUMANITY AND SUBCONTRACTOR. Scope of Work. Framing Labor. Framing Labor Division 120

Section 5 Crew Requirements

May 2013 CONSTRUCTION MANUAL

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

Crockett Log & Timber Homes May December, 2017 Program Pricing Book

SES FOAM 0.5 LB SPRAY INSTALLATION INSTRUCTIONS

Chapter 4: Insulation

Pulaski County, Virginia Practical Wall Bracing

ENERGY SAVINGS FOR LIFE

LIQUID APPLIED FLASHING

10 EXTREME BASEMENT PANELS

9.36. Energy Efficiency

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

Featuring Selection and Installation Information for Lateral Wind Loads

EPA Seal and Insulate with ENERGY STAR Insulation Product Certification Report: GAF EnergyGuard Polyiso Insulated Sheathing Board Insulation

Choosing INSULSPAN SIP Walls

Transcription:

ROOF & WALL SYSTEMS "After 37 years experience, over 3,000 homes, I spent 2 years researching the market for affordable, energy efficient products for the emerging wave of "green housing". I use the Ray-Core panel because you know in your heart, when using the Ray-Core panel; you have given the structure and the buyer, a gift that keeps on giving, (savings) every day for the life of the structure. My total electric home has run about $200 a month for 38 years. If I had Ray-Core panels for those 456 months my bill would have been cut in half, a savings of $45,600 that could have been invested elsewhere, not to mention the energy saved and the pollution prevented." Ken Auvil W.V. Green West Virginia FINALLY A AFFORDABLE BUILDING SYSTEM THAT: -EXCEEDS or MEETS all CODES -EASIER and FASTER to INSTALL -MAKES BUILDERS STANDOUT in the MARKET Cost and energy efficiency is now the demand of home buyers. Federal and local mandates, owner requirements, and wise builder/developers are looking for the edge in home design and energy savings.

WALL SYSTEMS Introducing the all new Staggered Stud Standard Panel Features: -Standard Integrated Metal or Wood Studs 16 or 24 O.C. -2x4, 2x6, 2x8 Studs, 4 Wide and up to 12 in Length *custom sizes available -Polyurethane Foam Insulation, Class 1 Fire Rated -Paper thin Foil Radiant Flame Retardant Vapor Barrier -Superior Sound Deadening Properties Panels Utilize Standard Framing Practices: -Panels Incorporate Standard Framing Lumber -No special Requirments -Built using standard conventional IBC, ICC framing methods -Windows & doors are built the same as always Where Energy Savings Meets Brilliance R-VALUES 2x4=R26 @ 50 F 2x6=R42 @ 50 F 2x8=R52 @ 50 F

WALL SYSTEMS FAST AND EASY INSTALLATION NO SPECIAL SKILLS NECESSARY When is the last time you Framed, Insulated & Wrapped a house in one day? Step 3 -Nail on the top and bottom plates hitting studs that are 16" or 24" o.c. Step 1 -Layout top & bottom plates. -Nail all window and door frames together. -Place windows & doors into desired location & nail top & bottom plates into king/trimmer studs. Step 4 -Stand wall the same as typical framing. Step 2 -Carry the necessary panel to the layout location. (each 2x4 panel weighs just 40lbs.) -Cut panel to fit your required layout using a circular saw. Isn t it amazing how fast you can Frame, Insulate, & Wrap A Home with RAY-CORE Panels?

ROOF SYSTEMS Are you using TJI s in your roof system? TJI Hybrid Block Panel System Standard Roof Panel Features: -Standard integrated wood members 16 or 24 O.C. -3.5, 5.5, 7.25 by 4 wide and up to 12 in length *custom sizes available -Polyurethane foam insulation, class 1 fire rated -Paper-thin, foil radiant, flame-retardant vapor barrier -Superior sound deadening properties -Approved for vented & non vented roofs Panels Simplify Roof Framing Practices: Ship lap interlocking system Simply Smart Energy Saving Products Integrated wood members provide a screw & nail base. These wood members transfer the weight of the roof through the members to the rafters or tongue & grove, keeping the foam molecules from collapsing which degrades the R-Value over time. Foil radiant vapor barrier on both sides help eliminate the thermal transfer through the integrated wood members by 89%. With RAY-CORE polyurethane foam, topped off with a foil-radiant vapor barrier on both sides, SIP quality is brought to a new level. R-VALUES 3.5=R26 @ 50 F 5.5=R42 @ 50 F 7.25=R52 @ 50 F

ROOF SYSTEMS When can I use roof panels? -Vaulted, open-beam roof applications (vented & non vented) -Air conditioned attic spaces -TJI roof systems -Truss roof systems The Simple & Smart Roof Panel How are RAY-CORE roof panels installed? Injected class 1 fire rated polyurethane foam core Rafters or trusses per structural requirements 4-12 self drilling SIP screws are screwed through wood member into decking or rafters Integrated roof nail base 16 or 24 O.C. RAY-CORE s roof panel design resolves MOLD, MILDEW, and WATER DAMAGE issues. Roof Sheathing can be nailed to the integrated wood in the factory, although it is recommend to be nailed on the jobsite. This allows for the OSB or Plywood to overlap the panel joints insuring a stronger airtight roof system. *Unlike most sandwich panels, RAY-CORE will not inject polyurethane foam directly to the OSB O board. When OSB gets wet during installation or because of a roof leaks, ice i damming, condensation or other common roof problems, it begins to swell, grow mold, mildew, and break down. This swelling diminishes the integrity of the sheathing requiring it to be replaced. If the OSB is glued to the t foam the whole panel has to be replaced in order to fix the damaged roof decking. This is the case with other SIP sandwich panels.. But with RAY-CORE, simply pull up the damaged sheets of OSB and replace them. RAY-CORE is the far superior solution. 1-877-552-2440