Evaluation of Pile Jackets on the Hampton Roads Bridge and Tunnel

Similar documents
research report Virginia Transportation Research Council Final Report VTRC 10-R13 BRIAN M. PAILES Graduate Research Assistant

FDOT CATHODIC PROTECTION PRACTICES FOR BRIDGE PRESERVATION

Corrosion Evaluation of Prestressed Piles in Refit Wharf #3

DO EPOXY-COATED BARS PROVIDE COST-EFFECTIVE CORROSION PROTECTION? FHWA Highways for Life David McDonald, Ph.D., P.E.

Corrosion-Free Carbon Fiber Reinforced Polymer for Prestressed Piles

The Leader in Underwater Piling Repair Technology

Designing Bridges for a 100-year Service Life. TEAM Conference 2016

Corrosion Initiation at Chl. Threshold (C T )

MONITORING CORROSION ACTIVITY IN CHLORIDE CONTAMINATED CONCRETE WRAPPED WITH FIBER REINFORCED PLASTICS. Abstract. Introduction

REINFORCED CONCRETE CORROSION PERFORMANCE IN FLORIDA BRIDGES

Proceedings PRO 89. Proceedings of the RILEM International workshop on performance-based specification and control of concrete durability.

LONG-TERM CORROSION BEHAVIOR OF EPOXY COATED REBAR IN FLORIDA BRIDGES

Rehabilitating Bridge Substructures with FRP Materials

PRECAST PARKING GARAGES

3. INSPECTION FINDINGS

HALLS RIVER BRIDGE REPLACEMENT

Concrete Parking Garage Degradation

VITCON 9001 RCI Bipolar Roving / Migratory Corrosion Inhibitor Admixture For Reinforced Concrete

Bridge Preservation: Completed, Ongoing and Future Research

Corrosion-resistant rebar extends service life of concrete bridge structures

UNDERWATER BRIDGE INSPECTION REPORT STRUCTURE NO CSAH NO. 15 OVER THE ARCOLA CHANNEL HENNEPIN COUNTY

Repair Application Procedures

PortMiami Rail Intermodal and Bascule Bridge Rehabilitation Project TIGER II Grant

Bridge Preservation Corrosion Mitigation Option in Concrete Repair Systems

st. johns river OWER ARK A Joint Venture of Prepared by: John E. Reid, JEA Presented by: Kent Zammit, EPRI

TIDAL WRAP CORROSION PROTECTION FOR MARINE PILINGS

DESIGN STANDARDS DEVELOPMENT REPORT FOR CORROSION RESISTANT PRESTRESSED CONCRETE PILES (INDEX No Series FY Design Standards)

CORROSION OF EPOXY COATED REBAR IN CRACKED MARINE SUBSTRUCTURE CONCRETE

TECHNICAL SPECIAL PROVISION FOR CONCRETE REPAIRS. Financial Project ID , &

TECHNIACL SPECIAL PROVISION FOR NON-STRUCTURAL AND STRUCTURAL INTEGRAL PILE JACKET WITH SACRIFICIAL CATHODIC PROTECTION

Evaluation and Repair of Post-Tensioned Concrete

Sika FerroGard Surface Applied Corrosion Inhibitor for Reinforced Concrete

Cathodic Protection as a Corrosion Control Alternative

Galvanic Cathodic Protection of Concrete Structures. David Whitmore, P.Eng., FCSCE Vector Corrosion Technologies

System Preservation in Louisiana

A NEW CORROSION TREATMENT FOR PRESTRESSED REBARS: THE DIRECT INJECTION OF A CORROSION INHIBITOR BY AN ULTRASONIC PUMP

CONCRETE REPAIR IN ACTION: USING THE MANUAL AS A GUIDE. Christen Longoria, P.E. San Antonio District Project Engineer

PRO S AND CON S OF HALF-CELL POTENTIALS AND CORROSION RATE MEASUREMENTS

STRUCTURES SPECIFICATIONS FOR BRIDGE CONSTRUCTION ISSUES. John Westphal, P.E. State Construction Office January 2017

Corrosion Mechanisms, Monitoring, and Service Life Enhancement of Reinforced Concrete Structures

INNOVATIVE SOLUTIONS FOR REINFORCEMENT CORROSION

Report: Results of Questionnaire on the Effect of Cracks on Durability of Reinforced Concrete Structures

Protecting Concrete Structures Against Corrosion Damage. David McDonald, Ph.D., P.E., FACI, Epoxy Interest Group of CRSI

European Standard En 1504

REPAIR AND CATHODIC PROTECTION OF SUBURBAN CONCRETE BRIDGES

HALF-CELL POTENTIAL MEASUREMENTS TO ASSESS CORROSION RISK OF REINFORCEMENT STEELS IN A PC BRIDGE

1. CORROSION OF REINFORCEMENT

2014 NBPPC. Siva Venugopalan Principal Engineer Siva Corrosion Services, Inc.

research report Summary Report on the Performance of Epoxy-Coated Reinforcing Steel in Virginia Virginia Transportation Research Council

Corrosion Mitigation Systems for Concrete Structures

EVALUATION & REPAIR OF CORROSION DAMAGED ROOF LIFT SLAB WITH WIRE POST-TENSIONING SYSTEM (BUTTON HEADS)

SACoMaTiS 2008 International RILEM Conference

CTRE Center for Transportation Research and Education

Rusty Boicourt, P.G. NDE & Materials Specialist Materials Testing & Inspection

CORROSION CONTROL OF ABOVE GROUND STORAGE TANK BOTTOM STEEL PLATES USING ALUMINUM MESH ANODE WITH NEWLY DEVELOPED BACKFILL

Post-Tech PTI Impregnation System. Corrosion Protection System for Bonded Post-Tension Tendons

Surface Resistivity as a Performance Test for Transport Properties

WHAT ABOUT STRAY CURRENTS WITH STEEL FIBRE REINFORCED CONCRETE

Evaluation of Current Condition State of Reinforced Concrete Structures Exposed to Severe Environmental Condition

History of EFC-WP 11 Corrosion in Concrete

EXECUTIVE SUMMARY POST-TENSIONING TENDON PROTECTION STRATEGIES FOR PRECAST ELEMENTS

Protecting the Coastal Infrastructure against the Coupled effects of Corrosion and Catastrophic Fire

5. CONCLUSIONS, RECOMMENDATIONS, COST ESTIMATES

PERFORMANCE EVALUATION OF CORROSION INHIBITORS AND GALVANIZED STEEL IN CONCRETE EXPOSURE SPECIMENS

PARTIAL-DEPTH PRECAST DECK PANEL DESIGN AND CONSTRUCTION IN TEXAS

Florida Atlantic University, U.S.A, D = diffusion coefficient ( m / s ) eff

Corrosion Protection for Concrete Structures in Marine Environments. D.B.McDonald, Ph.D., P.E, FACI

UNDERWATER BRIDGE INSPECTION REPORT STRUCTURE NO COUNTY STATE AID HIGHWAY 10 OVER THE POMME DE TERRE RIVER DISTRICT 4 STEVENS COUNTY

National Roads Authority

UNDERWATER BRIDGE INSPECTION REPORT STRUCTURE NO MSAS NO. 119 OVER THE RED LAKE RIVER DISTRICT 2 - POLK COUNTY, CITY OF EAST GRAND FORKS

PmB - Bridge Deck Waterproofing System

Use of FRP to Strengthen and Repair Marine Structures

FX-70 Inert Corrosion-Free Structural Repair and Protection System

REFURBISHMENT Sika FerroGard -903 Plus THE UNIQUE MULTI-FUNCTIONAL SURFACE APPLIED CORROSION INHIBITOR FOR REINFORCED CONCRETE

Where Intelligence Meets Infrastructure PA AWWA Conference

EPOXY COATED REINFORCEMENT STUDY. Final Report

SPECIAL SPECIFICATION 4900 Sacrificial Cathodic Protection Pile Jacket

Federal Highway Administration Long-Term Bridge Performance Program. for South East Bridge Preservation Partnership April 13, 2011

Mr. Eric Ryffel, Manager October 5, 2015 Sanibel Beach Club 626 Nerita Street Sanibel Island, Florida 33957

Bridge Deck Preservation Treatment Options

REFURBISHMENT Sika FerroGard -903+

Corrosion Monitoring of Steel Bars in Port Concrete Structures

I-64 DUNLAP CREEK BRIDGE REHABILITATION JOINTLESS BRIDGES, DECK OVERLAYS, AND CONCRETE MATERIALS

Testing of Randolph Street Bridge

Guidance for repair/rehabilitation of concrete transport infrastructures (CTIS)

FINAL REPORT EVALUATION OF CORROSION INHIBITORS FOR CONCRETE BRIDGE DECK PATCHES AND OVERLAYS. Michael M. Sprinkel, P.E. Associate Director

Corrosion Assessment for the Failed Bridge Deck Closure Pour at Mile Marker 43 on I-81

FINAL REPORT. Gerardo G. Clemeña, Ph.D. Research Scientist

Iron is found in an oxidized state and is mined from the ground as an iron ore.

Results of Questionnaire on the Effect of Cracks on Durability of Reinforced Concrete Structures

TIDAL WRAP CORROSION PROTECTION FOR MARINE PILINGS

Rational approach for the management of a medium size bridge stock

Durable Fiber Reinforced Polymer Bar Splice Connections for Precast Concrete Structures

REQUESTS FOR ACTION (RFA)

AREMA COMMITTEE 8. Letter Ballot Number

Copyright. Stewart Mason Verhulst

COMPUTATION OF CORROSION DISTRIBUTION OF REINFORCING STEEL IN CRACKED CONCRETE

SIAMA. SIAMA Asset Management Technologies Level-2 Bridge Condition Inspection

A new approach for the patch repair of car parks using galvanic anodes

Review of Cathodic Protection Systems for Concrete Structures in Australia Lessons Learnt and Future Directions

Transcription:

Evaluation of Pile Jackets on the Hampton Roads Bridge and Tunnel March 5 th 2010 Brian M. Pailes, M.S., E.I.T. Research Scientist, Structural Stephen R. Sharp, Ph.D., P.E. Research Scientist, Materials Michael C. Brown, Ph.D., P.E. Research Scientist, Structural A partnership of the Virginia Department of Transportation and the University of Virginia since 1948

Outline What is Pile Jacketing Conclusions from a Study Conducted by Florida Department of Transportation (FDOT) on Jacketed Piles Hampton Roads Bridge and Tunnel (HRBT) Methods of Pile Evaluation Results Conclusions Recommendations

Pile Jacketing What are Pile Jackets Method of Protecting Marine Piles from Corrosion Damage Fiberglass Stay-in-Place Form Mortar or Epoxy Fill Steel Reinforcement in Mortar Fill Intended to Prevent Oxygen, Water, and Chloride Intrusion to Pile Substrate Stopping any Current or Future Corrosion Activity

FDOT s Results Jackets Removed from Piles Revealed Extensive Damage Accelerated Corrosion Damage Hidden Behind Jacket Cumulative Percent Figures Courtesy of William Hartt

Differences Between Florida & Virginia From a Corrosion Standpoint, Harsher Environment in Florida Florida Higher Average Temperatures Bridge Located in Salt Water Virginia Lower Average Temperatures Bridge Located in Brackish Water Temperature ( o F) 90 80 70 60 50 40 30 20 10 0 Florida Virginia D J M M J A S N J Month

Hampton Roads Bridge Tunnel 2 Tunnel Sections 4 Bridge Structures 1840 Total Piles 1511 Piles Jacketed Structures 2902 & 2827 Sheltered by Old Point Comfort Approximately Half of the Piles Have Been in Service for 53 years

TEST AREA

Methods of Evaluation Visual Assessment Initial Visual Inspection Performed from a Boat Half-Cell Potential Measurements Copper/Copper Sulfate Reference Electrode Measurements made in Marine Splash Zone Chloride Analysis Collected Concrete and Mortar Samples Samples from Marine Splash Zone Determined Total Chloride Content at ½ Increments Resistivity Measurements 4 Point Werner Probe Measurements made in Marine Splash Zone Jacket Autopsy Removed Sections of Jackets on Select Piles

Visual Condition Rating Fiberglass Condition 0. Jacket Not Installed 1. Fiberglass Intact 2. Fiberglass Split 3. Less Than 50% of the Fiberglass is Missing 4. More Than 50% of the Fiberglass is Missing 5. Fiberglass is Completely Missing

Visual Condition Rating Mortar Condition 0. Jacket Not Installed or Fiberglass obstructs view of Mortar 1. Mortar Intact 2. Corrosion Product Formed from WWF 3. Less Than 50% of the Mortar is Missing 4. More Than 50% of the Mortar is Missing 5. Mortar is Completely Missing

Visual Condition Rating Substrate Condition 0. Jacket Obscures View of Substrate 1. No damage 2. Corrosion Product 3. Significantly Large Cracks are Visible 4. Concrete has Spalled Away 5. Severe Section Loss in the Pile, Necking

Visual Condition Rating Overall Condition Rating Determined by Equation that was Developed Overall Condition Rating = Jacket Condition + Mortar Condition*3 + Substrate Condition*6 Weighted Summation Value Overall Visual Condition Rating 1 Condition 1 2-8 Condition 2 9-14 Condition 3 15-21 Condition 4 22-50 Condition 5

Legend Condition 1 Pile Pile with Preexisting Damage Condition 2 Pile Condition 3 Pile Pile Evaluated During Study Condition 4 Pile Condition 5 Pile Pile Scheduled to Receive 2 nd Gen. Jacket

N

N

N

N

N

N

N

N

N

Structure 2902 Visual Condition Rating Structure 2900 0% 19% 1% 8% 10% 5% 45% 18% 75% Structure 2827 19% Structure 2866 0% 7% 0% Condition Rating 9% 2% 1 2 3 4 5 37% 56% 30% 56% 3%

Half-Cell Measurements High Potentials Even in Good Piles 64% of the Measured Potentials more Negative Than -0.300 V -0.600-0.500 Half-Cell Potentials (V) -0.400-0.300-0.200-0.100 0.000 0 1 2 3 4 5 Visual Condition Category

Chloride Analysis Chloride Content at Steel depth 25% of Samples Below 1 lb of Cl/yd 3 of Concrete 63% of Samples Above 2 lb of Cl/yd 3 of Concrete The Chloride concentration for Corrosion Activity are Present in many Jacketed Piles 16 Chloride Concentration (lbs/yd 3 ) 14 12 10 8 6 4 2 0 0 1 2 3 4 5 6 Visual Condition Category

Chloride Analysis Chloride Diffusion of Mortar Occurring in Both Directions Jacket Wicks Water Diffusion from Substrate 8.0 Chloride Concentration (lb/yd 3 ) 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 0 1 2 3 4 Depth (in)

Resistivity 54% of Mortar Resistivities Below 10 kohm-cm All Substrate Concrete Resistivities above 10 kohm-cm Mortar Less Resistant to Corrosion Activity than Concrete 90 80 Resistivity (kohm-cm) 70 60 50 40 30 20 10 0 Mortar Concrete

Jacket Autopsy Steel in Jackets Minimal Mortar Cover Corrosion Initiates Quickly Causing Mortar Section Loss

Jacket Autopsy Mortar without Steel No Corrosion Product Mortar in Good Condition Mortar Intact on Pile

Jacket Autopsy Pour Mortar Quality Significant Honeycombing Objects Cast into Mortar

Jacket Autopsy Damage Behind Condition 1 Jacket Jacket Appeared to be in Excellent Condition Cracking of Substrate Hidden Light Corrosion Product on Substrate Steel

Jacket Autopsy Severe Damage Behind Condition 5 Jacket Large Cracking Significant Section Loss of Prestressed Tendon

Jacket Autopsy Piles rated before and after autopsy Condition rating values increased following autopsy Structure Bent Pile Pre-Autopsy Condition Rating Post-Autopsy Condition Rating 2866 67 G 1 4 2866 67 H 1 3 2900 5 B 1 4 2900 45 A 1 2 2900 45 B 5 5 2902 23 C 4 5

Conclusions Observed Damage Not as Severe as in Florida Most Likely Due to Milder Environment Jackets Hide Damage Jackets do not Rehabilitate or Stop Corrosion when Applied to Piles with Existing Corrosion Damage Steel Reinforcement in Jacket Mortar is Detrimental to Jacket Life Jacket Mortar is of Low Quality and Poor Construction

Recommendations Discontinue Use of Traditional Pile Jacketing with Mortar Fill If Jackets Are Used on Newly Constructed Piles, They Should be Epoxy Filled If Jackets Are to be Used on Existing Piles, They Should Include Cathodic Protection Prioritize Piles For Repair of HRBT Structure Start with Condition 5 Piles and Piles with Damage Prior to Jacket Installation

Thank You A partnership of the Virginia Department of Transportation and the University of Virginia since 1948