Solar Electric Systems Safety for Firefighters

Similar documents
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Basic technical information on solar PV. Welcome and introduction.

Santa Monica Fire Department SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE 2008 TABLE OF CONTENTS

Beverly Hills Fire Department SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE 2008 TABLE OF CONTENTS

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan)

Solar Power Owner s Manual

Basic technical information on solar PV

Basic technical information on solar PV

Basic technical information on solar PV. Welcome and introduction.

CITY & COUNTY OF DENVER COMMUNITY PLANNING & DEVELOPMENT BUILDING PERMIT POLICY

MARBLEHEAD FIRE DEPARTMENT Standard Operating Guideline Draft for Photovoltaic/Solar Installations

Reference Information:

PV Primer. building science.com. Building America Report June-2002 Building Science Corporation. Abstract:

SOLAR ELECTRIC SYSTEMS

future-proof energy with photovoltaic systems

PHOTOVOLTAIC (PV) SUBMITTAL REQUIREMENTS

ROOFTOP PV GUIDELINES FOR SAFE AND LEGAL INSTALLATIONS IN CAPE TOWN

PV System Components

COUNTY OF RIVERSIDE BUILDING AND SAFETY DEPARTMENT PHOTOVOLTAIC PERMITTING GUIDELINES

ASSESSMENT AND DESIGN OF ROOFTOP SOLAR PV SYSTEM. Click to begin

What s Happening. Solar Power. Johnny Weiss Executive Director. 3/11/2005 Solar Energy International (SEI) 1

2017 NEC Changes for Renewable Energy Systems Session one by Christopher LaForge

CITY OF LA MESA FIRE DEPARTMENT SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE

Running the Electric Meter Backwards: Real-Life Experience with a Residential Solar Power System

Guidelines for Solar Photovoltaic Installation

Rooftop Solar PV System Designers and Installers. Training Curriculum. APEC Secretariat

SOLAR ENERGY CHRIS PRICE TECHNICAL SERVICES OFFICER BIMOSE TRIBAL COUNCIL

Solar Power for Ham Radio. KK4LTQ

Residential Solar Energy Systems: Solar Hot Water and Solar PV. Darren C. Anderson, MSc Renewable Energy Director of Operations Sungrid Ltd

Solar Energy 101 What You Need to Know to Go Solar

Metal Roo ng + Solar Arrays: The Perfect Combination. Photovoltaic Technology

IEC Installation Guide for SERAPHIM Photovoltaic Module

DC Surface (non-submersible) pumps are most economical. Reduce pumping energy by half

Farm Energy IQ. Solar Energy on Farms. Farms Today Securing Our Energy Future. Ed Johnstonbaugh, Penn State Extension

RECOMMENDATIONS FOR EXPEDITED PERMITTING FOR SMALL PV SYSTEMS

LECTURE 15 PHOTOVOLTAIC MATERIALS. ECE 371 Sustainable Energy Systems

Tindo Karra. Installation and Specifications Manual. Introduction

Guideline for Fire Safety. Elements of Solar. Photovoltaic Systems

PHOTOVOLTAIC INSTALLATION GUIDELINES

Address of Installation Building Permit #

Building and Safety Division Public Information

How do weather, environment and location affect solar?

AN EFFECTIVE STUDY ON PERFORMANCE ANALYSIS OF GRID CONNECTED PV SYSTEM

LEED, Alternative building Materials, Alternative Energy. Yossi Bronsnick 10/8/2015

PHOTOVOLTAIC SYSTEMS. Syllabus. 1 Photovoltaic systems

Utility Connections, Safety & Code Issues

FUSION Direct PV Powered LED

5. Solar Photovoltaic System

PV Safety Webinar. Helping Ensure Safe PV System Installations. 2-5pm, 18 th February 2011 Nationwide Online Seminar

We ve cracked the code to harness the sun

Farm Energy IQ. Solar Energy on Farms. Farms Today Securing Our Energy Future. Ed Johnstonbaugh, Penn State Extension

WITH THE TITLE 24. replacement. story. stories, etc. R disconnects. to, PV. unit and any. supporting frame. conditions. greater than the main

PHOTOVOLTAICS HISTORY OF PHOTOVOLTAICS

1. The plan needs to show compliance with the 2013 CEC, 2013 CBC and 2013 CRC. [ CBC] RESPONSE:

A CASE STUDY OF A RESIDENTIAL PHOTOVOLTAIC SYSTEM WITH MICROINVERTERS

NY State Unified Solar Permit

POOLS, SPAS AND HOT TUBS

GEOS / ENST Problem set #Grid Due: Tues. May 18

E.3.5 PHOTOVOLTAIC SYSTEMS TABLE OF CONTENTS UNSW DESIGN & CONSTRUCTION REQUIREMENTS WEB ENTRY PAGE

NY State Unified Solar Permit

Working in roof spaces Guidance note. Government of Western Australia Department of Mines, Industry Regulation and Safety WorkSafe

Residential Rooftop PV

Building Codes in Effect: 2010 California Building, Residential, Fire, Energy and Electrical Codes, including Article 690.

Solar PV Energy Management System. Turns surplus power into free hot water. dimplex.co.uk/free-e

Fact sheet. Photovoltaic systems. Why consider photovoltaics?

Consumer s Guide to Solar Power

NY State Unified Solar Permit

Small Scale Solar Permit Application

In addition to standard plan requirements, all plans submitted for PV installation shall include the following details:

KNOW ALL ABOUT SOLAR

Design Installation and Testing of 1.6 kwp GPV System

AORC Technical meeting 2014

TallSlateTM Grandee Installation Manual

TITLE 9 CHAPTER 4 SOLAR ENERGY

NY State Unified Solar Permit

A Local Law amending Chapter Section 139, The Zoning Law of the Town of Lysander, New York.

Impact of PV Energy Resources on the Quality of power of the Electrical Power System

AS/NZS 3000: 2018 Changes to Wiring Rules Standard

Reference: Photovoltaic Systems, p. 229

NY State Unified Solar Permit

Solar in Minnesota. February 27, 2013

Small Scale Domestic Rooftop Solar Photovoltaic Systems

Solar PV, Wind, and Storage System Design. Ilya Chernyakhovskiy, NREL April 26, 2018 Dushanbe, Tajikistan

Solar Learning Lab. User s Guide. Heliotronics, Inc Main Street Hingham, MA (781) FAX (781)

The IET solar PV code of practice: what this means for you

Look Inside To Determine Your Home s Solar Energy Needs

Photovoltaic power systems are a rapidly growing

Photovoltaics (PV) Solar Electricity

NY State Unified Solar Permit

A Review Paper on Solar Energy System

REVISION NO.: 8 EFFECTIVE: 03/26/18

We ve cracked the code to harness the sun

Grid-Tied PV System with Energy Optimization

6KW Grid Interactive Photovoltaic System

NY State Unified Solar Permit

Safety through module electronics? Less is more!

NY State Unified Solar Permit

Transcription:

Solar Electric Systems Safety for Firefighters AUTHOR: Ted Spooner Chair of the Australian standards committee responsible for PV systems Co-convener of the International Electrical Commission (IEC) working group on PV systems: TC82-WG3. September 2011

Solar Electric Systems Safety for Firefighters September 2011 BY Ted Spooner Chair of the Australian standards committee responsible for PV systems Co-convener of the International Electrical Commission (IEC) working group on PV systems: TC82-WG3. Preface Many Solar Electric (Photovoltaic or PV) Power systems have been and continue to be installed in Australia. Over recent years there has been a rapid expansion of the industry and this is expected to continue into the future. These systems are typically installed on roofs or may be installed on ground mounted racks. Although fires caused by the PV systems themselves are rare, it is important for firefighters to be aware of the safety issues that might be involved when fighting a fire on a structure that incorporates a Photovoltaic (PV) System. The basic information provided here will help in identifying when a PV system is present, its basic operation, what hazards exist, what is safe and how to minimise risks. Much has been written lately on this topic. Some information, unfortunately, has been inaccurate, and it is hoped that this document will assist in clearing up some misconceptions. Short courses on PV systems and safety for fire fighters can also be arranged through the Australian PV Association on request. This document discusses Grid-connected Systems which are the most prolific systems in Australia. It addresses the questions: Disclaimer What components comprise a system? What issues are important when you arrive at a fire location? o How can I identify if a PV system is present at an installation? o How do I shut down a System? o Once shut down, are there still hazards? Issues related to water on a PV array Safety issues when entering a fire compromised building. This brochure provides only general information. In the event of fire, site specific advice should be sought. Neither the APVA nor Ted Spooner will be liable for any loss or damage caused by use of the information herein.

Contents Preface...2 Grid Connected Systems...4 Introduction...4 System Components & Connection Diagram...5 What issues are important when you arrive at a fire location?...6 How can I identify if a PV system is present at an installation?...6 How do I shut down a PV System?...7 Once shut down are there still hazards?...8 Issues Relating to Water on PV arrays and structures...8 When Entering a Building...8 Other Issues...8 SUMMARY...9 APPENDIX A: Identification of System Components...10 Solar Panels or Modules...10 Solar Thermal panels...10 Photovoltaic (PV) modules:...11 Inverters and Disconnects...14

Grid Connected Systems Introduction Grid connected systems are at the present time the most predominant PV systems installed. They only exist where an installation is connected to the main electricity supply system ( The Grid ). Many of these systems have been installed on domestic roofs. An example of a domestic roof installation is shown in photo 1. Photo 1. Example of Domestic roof PV System Larger commercial installations can take many forms: either installed on a roof of a commercial building (see photo 2); or installed on a ground mounted frame (see photo 3). Photo 2. Example of Commercial Roof Mounted PV System (Photo courtesy of Sydney Solar Pty Ltd) Note that in some installations PV arrays may be installed on more than one face of a roof.

Photo 3. Example of Commercial Ground Mounted PV System System Components & Connection Diagram Grid connected PV systems have three primary components: modules, inverters, and the wiring connections between the modules and inverter and between the inverter and the switchboard. A typical connection diagram is shown in Figure 1. In some cases of grid connected systems, batteries may be present to provide an uninterruptible power supply (UPS) function but this is unusual and from a safety perspective is no different to any other installation containing a UPS. The PV modules generate DC electricity while they are exposed to light. The amount of electricity generated is dependent on the size of the modules or complete system and the amount of light falling on the modules. The inverter converts the DC electricity into AC electricity that is compatible with the grid and injects this electricity into the grid. Unless the PV output is separately metered, grid connected PV systems will cause the electric meter to run backward on a sunny day when there is more power being generated than the house is using. At nighttime, the meter just spins forward again as house appliances are in use. The inverters for grid connected systems cease operation and disconnect from the grid if the grid supply is disconnected or fails for any reason. This includes someone switching off the main electricity supply to an installation.

Solar Modules Roof-Top DC Isolator DC Isolator Inverter Switchboard Figure 1. Typical domestic grid connected PV system diagram. Note: Some older systems may not have roof-top DC isolators What issues are important when you arrive at a fire location? How can I identify if a PV system is present at an installation? Determining the presence of a PV system is the first step in identifying potential risks. It is important for firefighters to be able to identify basic components of systems, such as the PV modules and the inverter. See appendix A for assistance with identifying these components. The existence of these components in an installation will alert firefighters to the existence of a PV system. Sometimes, because of the location of PV modules on a roof, it is difficult or impossible to see modules mounted on some parts of a roof. In all cases it is important if possible to go to the electric meter panel or switchboard where in both cases there is required to be a sign/s displayed indicating the presence of a system. See an example of this signage in photo 4. Note: This documentation covers only measures associated with a PV system. Other sources of generation and devices, such as UPS systems, must be treated separately as per usual safety procedures for these devices.

Photo 4. OR Example of Signage in Switchboard How do I shut down a PV System? In the case of grid connected systems, the most important first step where possible is to switch off or disconnect the main electricity supply to the installation. If this is accomplished, all the AC wiring in the installation should shutdown including the inverter supply from the PV system. If there is a shutdown procedure in the switchboard, those procedures where possible should be followed. See Example of Shutdown Procedure in Figure 2: Labels near associated switches Figure 2. Example of shutdown procedure and associated switch labels. The most important second step in shutting down a system is to switch off the PV Array DC isolator adjacent to the inverter system (refer to Figure 1). The location of the inverter should also be signed in the switchboard, if it is not immediately adjacent to the switchboard. Operation of this DC isolator should disconnect the PV array from any permanent earth connection. This will make the array electrically more safe. Some old and all new installations will also have a PV Array DC isolator adjacent to the PV array (typically on the roof) so for situations where access is possible this switch may also be opened to make sure that any wiring going away from the array to the inverter is also safe.

Once shut down are there still hazards? Once the a.c. mains to the installation is switched off, all the AC wiring should be safe. The PV system will not feed AC wiring in the installation after the mains have been switched off. After switching off or disconnecting the AC to an installation, the DC wiring coming from the PV modules to the inverter system may still have a dangerous DC voltage on it while there is any light falling on the array. This is certainly true in daylight conditions but may also be true under artificial lighting such as flood lights or with light associated with a fire. The electric current associated with PV arrays under artificial light is very significantly reduced compared to current under daylight, but still it must be treated as potentially hazardous to humans. Issues Relating to Water on PV arrays and structures Remember that while there is light the PV array will be generating electricity. Voltages on domestic systems may be up to 600V DC and on commercial installations up to 1000VDC. It is important to operate fire hoses in a fog mode to break up the water path and ensure a non conducting water stream. Note: Further research on the issue of water streams and current flow from PV arrays will be available before the end of 2011 from testing being undertaken by Underwriters Limited in the USA but until that time caution is important. Note: Generally speaking the shock hazard from a PV array if the AC system is switched off and the PV Array DC Isolator is switched off is likely to be much less than any shock hazard associated with normal AC power supplies. This is particularly true in low light conditions. When Entering a Building When entering a building that has been compromised by fire, firefighters should avoid contact with any wiring hanging down from ceilings or roof structures under PV arrays or in the path between the PV array and the inverter equipment. Again, if there is light on the PV array, some of these wires may be live unless all roof top isolator/s have been opened. Other Issues PV modules are not meant to be walked on - doing so could lead to a collapse. If your department carries noncontact voltage detectors, remember that they detect only the presence of AC voltage, not DC voltage. There is no noncontact detector on the market for detecting DC voltage. It is possible to make the PV array electrically safe using tarps to cover the array. Semitransparent tarps such as blue tarps are not suitable as they let too much light through. Silver, black or heavy canvas tarps are suitable and will reduce the available current from the array to a level that is safe. It must be emphasized that the whole array has to be covered to make this technique effective. On roofs with multiple sections of arrays, all sections of all arrays must be covered.

Photo 5. Tarping an array to make it electrically safe. Finally, remember that in a nighttime fire in which the ceiling/roof space has been exposed to severe heat damage, the conduit and wires inside may have become compromised. It is possible that when the sunlight contacts the array the next day, it could result in some arcing. It is a good idea to recheck a structure in the morning for arcing or rekindling from arcing until a qualified solar contractor can respond to disconnect the array connections. SUMMARY 1. On arrival, look for indications and signs associated with PV systems. 2. Turn off the AC supply. This will shutdown and disconnect the inverter. - AC house wiring safe. 3. Shutting down the DC isolator near the inverter will separate the array from earth. - Safer option. 4. Shutting down the rooftop isolator will make safe wiring coming down from the roof. 5. Use FOG spray when putting water on a fire. 6. When entering a building be aware of wires hanging down from the ceiling or roof structures in areas under PV arrays.

APPENDIX A: Identification of System Components Solar Panels or Modules There are two main categories of solar panels (modules) used in residences: Solar Thermal panels (photo A1 & A2), that are used for hot water systems and Photovoltaic (PV) modules which generate electricity (photos A4 to A8). This article deals only in detail with PV panels, also known as PV modules in the industry. It is important that fire-fighters are able to quickly distinguish the two different types. Solar Thermal panels Thermal panel systems may represent a physical load on the roof and may contain hot water. They sometimes have water tanks with electric or gas boost on the tank but the issues associated with these appliances are not covered in this document, other than to say that they need to be identified and do not represent the same risks as PV systems because they do not generate electricity. Photo A1. Solar thermal panels used for hot water Note: joined at top and bottom with water pipes Photo A2. Solar thermal panels with storage tank.

Solar Thermal Panels Solar PV modules Photo A3. House in Sydney Olympic Village Sydney with both solar thermal and solar PV electric panels Photovoltaic (PV) modules: Most of the PV electric modules installed today are comprised of many silicon cells wired together and enclosed in an aluminium frame with a glass cover. See photos A4 to A6. Crystalline and multicrystalline modules have individual cells that are easily seen under the glass in Photos A4- A6. Some modules are a double layer of glass with the cells sandwiched between to form a semitransparent module used often as atrium roofs or for shade elements in a building (photo A6). Amorphous cells are deposited as a thin uniform layer under the glass. See Photos A7-A8. Some amorphous modules come in the form of a thin plastic film that is bonded to metal deck roofing. See photo A8. Photo A4. Mono-crystalline PV modules Individual cells visible uniform colour generally dark grey.

Photo A5. Multi-crystalline PV modules. Photo A6. Example of Double Glass PV Module used as a shade element in a building.

Photo A7. Amorphous PV module Note: The individual cells are not apparent generally a uniform dark grey or bluish colour with fine lines on surface. Photo A8. Amorphous modules bonded to metal roofing. A group of modules mounted on a structure is called an array (photos 1-3). An array s weight load on a roof is usually less than 25kg/sq meter. The modules generate electricity from sunlight and have no moving parts. When modules are electrically connected to each other in series, the voltage increases. Most domestic residences will have from 1000 to 5000 watts (one to five kilowatts) of power in optimal sunlight conditions, at between 120 and 600 volts DC. The current typically ranges between five and ten amps. Of course there are both smaller and larger systems and Commercial PV systems can range up to 100s of kw through to megawatts. The larger systems typically being on open racks in fields (photo 3).

Inverters and Disconnects Since the modules produce DC power, they are wired to an inverter, which converts the voltage to alternating current (AC) and then feeds the electricity directly back into the main power distribution panel. Photo A9 shows, from left to right, the main electrical meter and circuit breakers which includes the AC disconnect, the inverter, and the DC disconnect underneath the inverter. Photo A9. Example of Inverter installation adjacent to switchboard. Note: The inverter may not always be mounted adjacent to the switchboard. Since the inverter requires AC from the power company to do its job, shutting off the residence s main circuit breakers also shuts down the inverter. This means that no AC power is being sent into the house. Similarly, if there is a local power outage on a bright sunny day, the system cannot feed power back into the power company grid because the inverter is shut down. Switches for a.c and d.c disconnects should be close to the inverter to shut off the DC power entering the inverter (the DC isolator/disconnect) and the AC power leaving it (AC isolator/disconnect). If the inverter is adjacent to the switchboard, as in the photo A9, the AC disconnect will generally be on the switchboard. Caution: The wires from the array to the inverter are live in the daytime hours, even when it is overcast. The DC disconnect does not shut off the power in the DC conduit coming from the array; it just keeps it from entering the inverter. The DC wiring is still live between the array and the inverter DC disconnect. As you can see in photo A9, this inverter is mounted close to the main switchboard. Inverters may also be installed in other locations. Instructions as to the location of the inverter should be located in the switchboard.