Effect of Storage Conditions upon the Resistance (D-value) of Spore Strip Biological Indicators (BIs) used in EtO Sterilization Monitoring

Similar documents
Written By Dr. Robert Ramaley (Univ. NE Med CTR), Mia Ware, Dan Pearson, and Christopher R. Dwyer* (Raven Biological Laboratories)

TECHNICAL DATASHEET. in compliance with: USP, ISO and all appropriate subsections FQ 106 v3.0 August, 2015

DUAL SPECIES BIOLOGICAL INDICATOR SPORE STRIPS For Monitoring Ethylene Oxide (EO), Steam and Chemiclave Processes

SterilAmp II Geobacillus stearothermophilus

PRODUCT D-VALUE STUDIES: A CRITICAL TOOL WHEN DEVELOPING A STERILIZATION PROCESS

Hygiene Monitoring. Biological Indicators for Monitoring Sterilization Processes. Product Information. BI_07_en

STERILIZATION VALIDATION IN THIS SECTION REPROCESSING VALIDATIONS FOR REUSABLE MEDICAL DEVICES. Radiation Sterilization Validation

Effect of Environmental Conditions During Heating on Commercial Spore Strip Performancet

Secure. Tested. Certified.

Consistent. Reliable. Innovative.

REUSABLE MEDICAL DEVICE VALIDATION

sterilisation monitoring products

Soleris system evaluation of testing applications for UHT/aseptic packs

ANALYTICAL REPORT: Comparison of the Microbial Recovery Efficacy of QI Medical EnviroTest Paddles versus a Conventional Contact Plate

Guidance for Industry

IN THIS SECTION MICROBIOLOGY TESTING EXPERT SOLUTIONS FOR PRODUCT DEVELOPMENT. Bacterial Endotoxin (LAL) Testing

Finding the Worst Case Location in Your Sterilization Load Just Got Easier

The Most Probable Number Method and Its Use in QC Microbiology

Overview of Inspection Issues with Legacy Products. Barbara Breithaupt Consumer Safety Officer

Chemical Indicators. Biological Indicators. Physical Monitors. Welcome! How do I get a CE Certificate? Learning Objectives

Sample for Use as a Guide Revised IDEXX ENTEROLERT TEST METHOD FOR THE DETECTION OF ENTEROCOCCI IN WATER

HardyVal TM CSP RANDOM TEST KIT

Sample for use a Guide Revised IDEXX COLILERT -18 TEST METHOD FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND E.

Study Title Antibacterial Activity and Efficacy of KHG FiteBac Technology Test Substance Using a Suspension Time-Kill Procedure

KILL-TIME STUDIES Antimicrobial Activity of EO H 2 O Using Clostridium difficile spores Test Solutions: Acidic H 2 O Submitted December 12, 2011

Post Sterilization Lab Contamination

2018 North America Lab Services Fee Schedule

Sterilisation Monitoring Products

Raven Labs. Sterility Assurance for Industry. Sterility Assurance Products Since A division of Mesa Laboratories, Inc.

New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765

Result:COMPLETE Report Date: December 28 th, 2015

CLENDO INDUSTRIAL LABORATORY. CUSTOMER SAMPLE ANALYSIS REPORT Page1 of 8. FDA No CLENDO CONTROL NO. 9081, 9095

ATCC ANIMAL CELL CULTURE GUIDE

Medline Gemini Sterilization Wrap. Test Studies

Coliform bacteria are quantitated by the fractional gram pour plate technique (Note 1). Test tubes containing gas collector tubes (Durham Tubes)

KILL TIME STUDIES Antimicrobial Activity of Advanced Cellular Silver (ACS) 200 Using Methicillin resistant Staphylococcus aureus (MRSA)


Instructions for Validation of Autoclaves

Quality Control LOAD CONTROL. VERIFY Load Control Products. Use to monitor and release instrumentation with confidence RECORD KEEPING & LABELING

Guidance. Media Fills for Validation of Aseptic Preparations for Positron Emission Tomography (PET) Drugs DRAFT GUIDANCE

Population Catalog Number. Log Log Log Combined (both B. atrophaeus and G. stearothermophilus)

ISO INTERNATIONAL STANDARD

Secure. Tested. Certified.

Standard Operating Procedure Title: Stock Suspensions of Micro-Organisms

Effective Heat Sterilization in CO 2 Incubators

How to Grow Mushrooms. featuring...

Submitted May 16, May 23, 2014 BY:

Optimization of Operating Conditions for Sterilization of Aseptic Food Packaging Material

Slide 1. Slide 2. Slide 3. Sponsored by Webber Training Inc. For more information contact Paul Webber

TIP-GUARD INSTRUMENT PROTECTORS. Products Designed and Manufactured by the Scanlan Family Since 1921

The Efficacy of 300 ppm Peracetic Acid from Perasan MP-2 and MP-2C on E. Coli O157:H7 Inoculated Meat Surfaces

Cleaning Efficiency of The MicroOne Wipe and Mop Cleaning System

3M Condensation Management Film (CMFi) Hygienic Evaluation of

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

HardyVal TM CSP MEDIUM-RISK LEVEL MEDIA-FILL CHALLENGE KITS

Moist Heat Terminal Sterilization for Controlled Release Materials

PHARMACY IV ADMIXTURE. Pharmacy 483 January 17, 2006 Kim Donnelly Affiliate Associate Professor

Verification Testing of Biological Indicators for Moist Heat Sterilization

How to Grow Mushrooms. featuring...

Decontamination Effectiveness of Esco Celsafe CO2 Incubator Sterilization Feature using High Heat Temperature By Bekti Tri Sumaryati

CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS

PHARMACY IV ADMIXTURE

Study Summary. Results: All tested media-filled vials were negative for growth of any microorganisms.

Exercise 23-C BACTERIOPHAGE REPRODUCTION AND PLAQUE FORMATION

Lab Exercise #4 Microbial Control Lab Exercise #4 Control of Microorganisms: Physical, Chemical and Chemotherapeutic

Sterilization - validation, qualification requirements. Sterilization - Overview

Advantages. Steam sterilization

Advantages. Steam sterilization

Biological Indicators

Persistence of Activity of a Hand Sanitizer

Submitted May 16, May 23, 2014 BY:

New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765

New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765

Media Fill Test Kits USP <797> COMPLIANT. HARDY DIAGNOSTICS. Low Risk. Medium Risk. High Risk

PRODUCT CATALOGUE. for gke Steri-Record Biological Indicators, Process Challenge Devices and Accessories

Product. Profile. For Industrial Applications. Medical Sterilization Specialties

The Most Probable Number Method and Its Use in QC Microbiology

September 8, MunnWorks, LLC 150 N. Macquesten Parkway Mount Vernon, NY 10550

TRYPTIC SOY AGAR (TSA) WITH LECITHIN AND TWEEN 80

Sanitization and endotoxin clearance in AxiChrom columns

Alpha HydroMAID Cleaning Effectiveness of the Alpha HydroMAID Cleaning System versus Conventional Mopping

Method Suitability Report Membrane Filtration Sterility Test with QTMicro Apparatus

Contact: To sterilize or decontaminate uniformly, superheated steam must contact all areas of the load.

INSTRUCTIONS FOR USE

Product Catalogue. for gke Steri-Record Biological Indicators, Process Challenge Devices and Accessories

( 주 ) 세현테크 TEL : FAX :

Biological Monitoring

Effective Use of Autoclaves

INSTRUCTIONS FOR USE. EZ-CFU Microorganisms INTENDED USE FORMULA COMPONENTS

TECHNICAL LEAFLET. MEDI-MEDIA-FILL KIT SUPPLY PACKAGE (Code: MR-25/S)

Case Study: Isolator Sanitisation Cycle Development, Validation and Revalidation.

CATALOG BIOLOGICAL AND CHEMICAL INDICATORS

á61ñ MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: MICROBIAL ENUMERATION TESTS

BACTERIAL BIOFILMS FORMATION AT AIR LIQUID INTERFACES

Validation Guide Sterisart NF

Validation Guide Sterisart NF

Transcription:

Effect of Storage Conditions upon the Resistance (D-value) of Spore Strip Biological Indicators (BIs) used in EtO Sterilization Monitoring Wendy Royalty*, Mia Ware, Russell Nyberg Raven Biological Laboratories, Omaha, Nebraska

Abstract Spore strip storage recommendations vary among manufacturers. The manufacturers recommended storage conditions range from freezing (-15 o C), to ambient (22 o C), to refrigeration (5 o C). This study investigated the various storage conditions and their effect upon EtO D-value resistance. Using commercially prepared Bacillus subtilis spore strips (ATCC #9372) prepared according to US Pharmacopeia XXIII performance parameters, spore strips from three different production lots were stored at the various recommended temperatures. Periodically, samples from each storage condition were removed and tested in a Joslyn/Steris EtO Biological Indicator Evaluator Resistometer (BIER) vessel to determine D-value using the Spearman-Karber Fraction Negative method. Population assays were performed according to USP XXIII, supplement 5 viable spore count to determine population stability. The resulting D-values were plotted and recorded. Resulting D-value changes were compared over time, and D-value change trends were graphically presented Introduction Ethylene oxide sterilization combines the lethal effects of the sterilent, exposure time, relative humidity and temperature on a microbial population. BIs are commonly used to monitor the efficacy of ethylene oxide sterilization cycles. This study focuses on the use of spore strips. To function as effective monitors, BIs should maintain a stable level of resistance

while being stored over a specific period of shelf-life time. If it is so important to maintain the resistance level in spore strips and other BIs, how and where should they be stored? This question is the primary focus of this experiment wherein three lots of spore strips inoculated with B. subtilis spores were stored and studied over a period of nine months. After inoculation of approximately 3,000 spore strips (1,000 per subtilis lot), they were assayed to find the population per strip, packed into glassine envelopes, and stored under differing conditions. Since manufacturers recommend the strips be stored in conditions which range in temperature from freezing (-15 o C), to refrigeration (5 o C) to ambient (22 o C). Our study was to compare these three storage conditions in order to determine the possible effects upon population and resistance for the three lots of BIs. In our study, the storage temperatures were -8 o C, 5 o C, and 27 o C. Materials and Methods Materials 1. One thousand of each lot of W-135GB, W-136GB and W-137GB spore strips in glassine envelopes. 2. Joslyn ethylene oxide BIER vessel. 3. Sterile Tryptic Soy Broth/Phenol Red (TSB/PR) prepared according to manufacturer s instructions.

4. Tryptic Soy Agar for population assays. 5. Incubator with temperature set at 35 o C. 6. Laminar flow hood. 7. Standard laboratory materials. Methods Raven Biological Laboratories manufactured three lots of spore strips containing one thousand biological indicators per lot. On July 10, 1998, population assays were done on the three lots of spore strips according to U.S. Pharmacopeia XXIII guidelines. Upon completion of the population assays, ethylene oxide exposures were run using a Joslyn Ethylene Oxide BIER vessel. The data was collected to determine an all-kill and allsurvive time with three dichotomous points in between. The Spearman-Karber (Fraction Negative) method was used to compute the D-values. The BIs within each lot were then divided into three sublots, and stored in a refrigerator (ref), freezer (fr), and on a shelf at room temperature (rt) for a total of nine months. Population assays were done again after nine months of storage in the strips respective environments. Change in spore count was noted and various EtO exposure times were run on each sublot of the three lots of spore test strips after nine months. The Spearman-Karber D- value was determined by exposing ten of each sublot of BIs to ethylene oxide at selected exposure times. Exposures were run in increments of one, two, or four

minutes. After the EtO exposures, the individual BIs were aseptically transferred from their glassine envelopes into 10-ml tubes of TSB/PR. The cultured samples were then incubated at 30 o -35 o C for seven days and observed for signs of growth daily. Positive growth was determined by a color change of the media from red to yellow and by its turbidity. The growth results for each exposure time were recorded. This data, combined with the results of the population assays, was used to determine the EtO D-value using the Spearman-Karber fraction negative formula listed below. A table created through the use of Microsoft Excel was also used to calculate the D-values. The data obtained from the assays and EtO exposures were then compared to the original results and graphed. Spearman-Karber (fraction negative) formula: D=U/(logN 0 +. 2507) U=T-d/2-(d/10 x Σf k-1 to f 1 ) D=D-value. U=mean time until sterility. N 0 =Population of sample. T=Time to achieve f k. f k =All samples sterile and adjacent to a dichotomous result. d=time interval between runs in

Results minutes. In the majority of the lots tested, populations dropped over the nine-month storage regardless of the storage conditions. All remained within an allowable population range to serve as a suitable EtO cycle challenge in relation to population (by USP standards). When compared to spore strips stored at room temperature, all of the three lots tested that were stored under freezer conditions showed a decrease in D-value. The average decrease was.3 minutes. Two of the three lots stored under refrigeration had a slight D-value or resistance increase over the nine months of storage. Microsoft Excel Chart 1 Microsoft Excel Chart 2 Microsoft Excel Worksheet 3 Microsoft Excel Chart 4 Microsoft Excel Chart 5

Discussion The challenge or resistance offered by a BI for a particular sterilization cycle is the important characteristic that needs to be maintained during the storage of the BIs. A BI stored under certain conditions that best maintains the population but reduces resistance or D-value is deleterious to the effectiveness, or the BI challenge. Resistance stability is of prime importance when evaluating storage conditions.

Conclusion Bacillus subtilis spore strips stored under the conditions of refrigeration and at room temperature seem to show the least overall change in resistance characteristics while strips stored under freezing conditions uniformly indicated that the resistance will decrease over extended storage. Decreased resistance will produce a less challenging BI. This study was only done with three lots of spore strips over a nine-month period of storage time. Extended studies covering a full twelve to twenty-four month range need to be done to confirm the indicated trends in resistance modification due to storage conditions.