Abstract. Introduction FILTRATION CHARACTERISTICS OF CMP SLURRIES. Author: Rakesh K. Singh, Ph.D., P.E., M.B.A.

Similar documents
CMP Pump Effects on Filter Life

Abstract. Introduction CMP FILTER CHARACTERIZATION WITH LEADING SLURRY PARTICLES. Authors: Yi-Wei Lu, Bob Shie, Steven Hsiao, H.J.

Betapure CMP Series. CMP Filter Capsules. Superior Reduction Of Large Particle Counts For Improved Yields. Features & Benefits.

Chemical Mechanical Planarization (CMP) Slurry Manufacturing

Susceptibility of Different Slurry Types to Agglomeration

Advances in LPC* Monitoring in CMP Slurries

Abstract. Next-Generation CMP Pad Conditioning. Introduction DEVELOPMENT AND PERFORMANCE DATA OF A NEW CVD DIAMOND CMP PAD CONDITIONER

pumps. These large particles can scratch metal and inter-level dielectrics potentially causing

Proper Filtration Removes Large Particles from Copper CMP Slurries

Importance of Monitoring Slurry and Ultrapure Chemical Flow in CMP Applications

Benefits and Limitations of Slurry Particle Analysis and the Need for Next Generation Capabilities. Budge Johl

Performance of an Entegris phasor X Heat Exchanger in Cabot Semi-Sperse 12

Slurry Handling, Troubleshooting and Filtration. Levitronix CMPUG Symposium Budge Johl Phoenix, AZ February 17, 2005

Investigation of New Maglev Day-Tank Technology for Effective Slurry Dispersion and Distribution

Challenges of Large Particle Size Analysis in CMP Slurries, and Opportunities for Improved Reliability

CRITICAL MATERIALS HANDLING IMPACT POINT-OF-USE PHOTOCHEMICAL FILTERS

Overview MICROGARD LIQUID FILTERS

EFFECTS OF SHEAR AND CAVITATION ON PARTICLE AGGLOMERATION DURING HANDLING OF CMP SLURRIES CONTAINING SILICA, ALUMINA, AND CERIA PARTICLES

Overview. MICROgARd LIqUId FILTeRS

Keeping Your CMP Slurry From Being A Pain in the As-Probed Die Yield. Robert L. Rhoades (Entrepix) Brian Orzechowski and Jeff Wilmer (DivInd, LLC)

Intercept Liquid Filters

Mechanism for LPC Pooling and Release in CMP Slurry Lines

Mechanism for LPC Pooling and Release in CMP Slurry Lines

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

AVS CMP Users Group Meeting

CMP Solutions for 10nm and Beyond: Breaking trade-offs in the Planarization / Defect Balance

Challenges of Slurry Distribution System Simulation for Fumed Silica Based Slurry. Pete Bridger JSR Micro NV

Post Cleaning Chemical of Tungsten Chemical Mechanical Planarization for Memory Devices. Jun Yong Kim Cleaning/CMP Technology

Impact 8G Series Photochemical Filters

Hollow fiber membrane nano-technology: Applied to purifying the chemistries for state of the art semiconductor devices.

Particle Characterization of Abrasives

Evolution and Revolution of Cerium Oxide Slurries in CMP

Get more filtration for the money with Flow-Max pleated cartridges for high flow, long life, greater sediment removal and reduced filtration costs.

CONTAMINATION CONTROL SOLUTIONS QUICKCHANGE CARTRIDGE AND DISPOSABLE FILTERS

A Hands-On Guide to Ultrafiltration/Diafiltration Optimization using Pellicon Cassettes

Tech Byte 11: Benefits of Filtration for Open Cooling Tower Systems

Improving Material-Specific Dispense Processes for Low Defect Coatings

Entegris Opens $55 Million Facility

PURELAB Chorus. Solutions for Type I Ultrapure Water

PDMPak Bottle System for Pressurized Applications

Separation and Purification Sciences Division. Betapure AU Series Rigid Filter Media Cartridges

Prevention of Microbubbles During Filtration and Particle Counting of High Purity Chemicals in the Semiconductor Industry

Post-CMP Cleaning: Interaction between Particles and Surfaces

PURELAB Chorus. Solutions for Type I Ultrapure Water

OXIDE STOP-IN-FILM CMP: NEW CHALLENGES FOR THE NEXT GENERATION MEMORY DEVICES. Andrey Zagrebelny, Sony Varghese, Andrew Carswell

A Production-Proven Shallow Trench Isolation (STI) Solution Using Novel CMP Concepts*

A Hands-On Guide to Ultrafiltration/ Diafiltration Optimization using Pellicon Cassettes

Effect of Retaining Ring Slot Design & Polishing Conditions on Bow Wave Fluid Dynamics

Hydrocyclone From Wikipedia, the free encyclopedia

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

Aeronex Gas Purification System HX Series


Czochralski Crystal Growth

Crossflow Filtration for Ink Jet Fluids

Preparation and Polishing Properties of Spherical Porous Silica Abrasive

2009 Market Slurries and Particles in CMP & a Bit Beyond

Mott All-Metal Catalyst Recovery Systems High-strength, high-efficiency filtration of particulate

MASTERBATCHES. Masterbatch Application and Selection Guide for Irrigation Pipes

Endex Foam Extrusion General Information Guide

Optimization of Distribution Loop Filtration and Its Impact on a Copper CMP Process

Role of amino-acid adsorption on Silica and Silicon Nitride surfaces

Separation / Classification / Concentration Murata Kogyo Co., Ltd. Hydrocyclone Separation System. FT Associates

Steven L. Alderman, Michael S. Parsons, and Charles A. Waggoner. Institute for Clean Energy Technology, Mississippi State University

Reducing Electrostatic Discharge In Semiconductor Fluoropolymer Fluid Handling Systems While Maintaining Chemical Purity

Slurry concentration [Vol.%]

rios Water Purification system The standard for laboratory-grade water

DESIGN AND OPERATION OF POROUS METAL CROSSFLOW MICROFILTERS

Rethinking dispersion

The History & Future of

Linx Consulting Inc. CMP TECHNOLOGIES and MARKETS to the 5 nm NODE. See Beyond the Horizon. Eighth Edition

G. GRANATH Ringhals AB S Väröbacka, Sweden

PURELAB CHORUS SYSTEMS

CMP MARKETS & VALUE CHAIN PERSPECTIVES

NCAVS CMPUG Meeting July 16, 2009

Column Packing of Cellufine Sulfate

Advanced Melt Blowing Technolog y

Heat exchanger performance of ground source heat pump by water cooling method

Sentry QCIII Quick Connect System

PERKASIL. Precipitated Silicas for the Rubber Industry

Particle Agglomeration Mechanisms in CMP Slurries

INTEGRATED-CIRCUIT TECHNOLOGY

High Efficiency Liquid-Solid Separators

Lenntech. Dow Liquid Separations. DOWEX Ion Exchange Resins. The Advantages of Uniform Particle Sized Ion Exchange Resins.

The World s Most Versatile Filter System

LiMCA III Liquid Metal Cleanliness Analyzer

CMP Process Development for Shallow Trench Isolation (STI)

Improving material-specific dispense processes for low-defect coatings

Photoresist & Ancillary Chemicals Manufacturing

Filters & Elements. People. Passion. Performance

Ultra High Molecular Weight Polyethylene (UHMWPE)

Fixed Abrasives and Selective Chemistries: Some Real Advantages for Direct STI CMP

Microfil GP. Range. Validation Guide. World Class Filtration Solutions

Particle Characterization using Acoustics and Electro Acoustics

WHAT IS PERLITE? MINING AND ORE PROCESSING

FILTRATION. Separation of solids from liquids by passing a suspension through a permeable medium which retains the particles

RiOs Essential 5, 8, 16, 24 Water Purification Systems

Line Filters Solid, simple, smart. Advanced reliability in compressed air. TECHNOLOGY YOU CAN TRUST

Line filters LINE FILTERS

Technological Breakthrough in Pad Life Improvement and its Impact on CMP CoC

Development of a New Tungsten Pad Utilizing Outsource CMP Capabilities

Transcription:

APPLICATION NOTE FILTRATION CHARACTERISTICS OF CMP SLURRIES Author: Rakesh K. Singh, Ph.D., P.E., M.B.A. Abstract Filters for current and next-generation CMP slurries must now exhibit high retention of particles above.5 μm while passing particles.3.2 μm in size at high flow rates and without significant pressure drop. We have developed a range of filters using various depth media that meet the requirements for the retention of large particles (>.5 μm) in slurries with sub-μm working particles. We demonstrate how 1.5 and 5. µm rated filters show suitable filter characteristics for use as point-of-use and distribution loop filters for silica slurry. Also, the importance of empirical evaluation in filter selection is demonstrated, with large variations in filter performance measured for.5 and 1. µm filters processing polystyrene latex (PSL) bead challenge solution, and silica, ceria and alumina slurries. Introduction The specifications for chemical mechanical planarization (CMP) processes are becoming more complex and demanding as new devices manufactured with new materials on larger wafers are introduced. The call for improved planarity and lower defect levels has resulted in the size of the working particles in CMP slurries being reduced. Slurry filtration to remove unwanted large particles while maintaining the required working particle size distribution (PSD) is critical to CMP process quality. Most CMP slurries now use 3 2 nm particles at typical concentrations of.3 12 wt % solids. Such slurry characteristics have resulted in increasing demand for high retention, low-cost,.5,.3 and.2 μm filters with stringent large particle counts (LPC) and PSD specifications. At the same time, such filters must have reasonably high flow rates and long lifetimes. If a filter removes particles in the working PSD range, it will become clogged and soon fail. The challenge to filtration technologies is especially acute if the difference in size between the particles to be retained and those to be passed is less than one order of magnitude. For filtering sub-μm CMP particles, depth media made from melt-blown fibrous materials are used (Figure 1a). Performance is strongly dependent upon the distribution of fiber sizes and the arrangement of the fibers within the media. 1, 2 Fibers with small diameters provide better retention and pressure drop characteristics than larger fibers, but a proper balance of fiber sizes is needed for optimal filter performance for any particular slurry. Filter media show a gradual transition from retention to passage over a range of particle sizes. This gives an s-shaped percent-retention versus particle size curve (Figure 1b). Given the move to more complex chip designs using thinner layers, there is a need to remove all particles greater than 5 nm from typical CMP slurries with working particle sizes of 3 2 nm. However, this is difficult to achieve when the transition curve of most media covers several microns. Filter media allowing passage at 2 nm may not reach retention above 8% until particle sizes are over 2 nm. However, there are several ways of sharpening the retention curve. By using multiple layers of the same media the required smaller particles will pass through while the larger particles will experience an increasing likelihood of capture at each successive layer. If the depth of media required to stop particles of a certain size happens to be small, then increasing the surface area of the media (for example, by pleating) further improves the large particle retention. Depth media can also be graded, placing more open layers at the filter inlet and tighter layers toward the outlet (Figure 1b). Filter design complexity is increased by the presence of gels in some slurries. To remove gels effectively without dramatic reduction in filter lifetime requires a large 3-D structure that allows gel capture through the depth of the most open media layers. Gel capture just on the top surface of the thicker media will quickly lead to flow-reduction ENTEGRIS, INC. 1

and blocking. Formation of this layer often leads to media compression and significant increase in retention as well as pressure drop. Silica-based slurry in particular requires consideration of gels while other slurries (e.g., alumina- or ceria-based) typically do not. Figure 1a. A typical graded density depth media for CMP slurry filtration. Retention (%) 1 Flow Ideal filter with sharp cutoff Particle Size Effect of each new layer Tighter filter media Wraps Core Figure 1b. The effect (a) of multiple layer depth media (b) on filter retention. More open media Flow out Flow in Tighter filter media More open media We have developed filters using the above depth media designs that meet the most demanding CMP slurry filtration applications. This paper demonstrates the suitability of the filters for processing slurry at the point-of-use (POU) and in the distribution loop. We also highlight the importance of empirical verification of a filter s performance with particular slurries as part of filter selection. Results from filtration studies of slurries for oxide (silica slurry), shallow trench isolation (STI) (ceria slurry) and copper (alumina slurry) CMP as well as PSL bead challenge solution are presented which show that retention, flow rate and pressure drop (Δp) have very different behaviors for the same filters processing different slurries. This confirms that CMP slurry filter optimization remains empirical in nature. We also show that graded density depth filters are effective in managing large particles in new CMP slurries. Methodology A silica slurry (silica-a with ~12 wt % solids) was evaluated to generate filter recommendations for distribution loop and POU filtration. In the first test, the slurry was re-circulated through an Entegris Planargard CMP5 5. μm nominal rating graded density depth filter (Figure 1a) for five hours at 4.3 L /min. In the second test, the slurry was filtered using an Entegris Solaris -1 1.5 μm nominal rating multiple layer POU depth filter (Figure 1b) at 4 ml /min, while being recirculated through the 5. μm loop filter. The distribution loop and POU filters performance was evaluated by monitoring the LPC and Δp in the filter. Slurry feed and filtrate LPC were measured using a Particle Sizing Systems AccuSizer 78 APS analyzer in the top chamber addition mode. The five-hour recirculated slurry from the above test was also filtered in single-pass tests using two graded density depth filters:.5 μm Planargard CS5 and 1. μm Planargard CMP1. A second set of experiments was conducted to obtain filter retention, flow rate and pressure drop data for above CS5 and CMP1 filters in different abrasive slurries. Each filter was used to process a ~25 wt % solids silica-based slurry for oxide CMP (silica-1), a <1 wt % solids ceria-based slurry for STI CMP (ceria-1) and a <1 wt % solids aluminabased slurry for copper CMP (alumina-1). Further tests were conducted with the tighter CS5 media to filter a different ~25 wt % solids silica-based dispersion (silica-2) and another <1 wt % solids alumina-based slurry for copper CMP (alumina-2). A MasterFlex peristaltic pump with Tygon long flex life tubing was used to feed the slurries through the filter media. With no filters in the loop, the pump passed DI water at ~5 and 535 ml /min for the CS5 and CMP1 test filter housings, respectively. A third set of experiments was conducted to obtain filter retention, flow rate and Δp data for a DI water-based PSL (polystyrene latex) bead challenge solution prepared using particles ranging from bead diameters of.772 to 2 micron. It is a common practice to use PSL bead challenge solutions to obtain relative retention data for various filters. These solutions are expected to retain stable particle size distribution and provide more consistent information compared to real CMP slurries which may change particle characteristics over time. Similar to CMP slurry samples, LPC for PSL bead samples were also measured using AccuSizer 78 APS in the top chamber addition mode. 2 APPLICATION NOTE ENTEGRIS, INC.

Results LPC results for the POU and distribution loop filters for silica-a slurry are presented in Figure 2. Figure 2a shows that the distribution loop LPC was stable in the five-hour run during which slurry undergoes ~17 turnovers or passes through the 5 μm CMP5 filter. In a real life fab operation, the slurry typically goes through one hundred turnovers before it is consumed. 3 Figure 2b shows the feed and filtrate LPC for 1.5 μm SLR1 POU filter in removing large particles from the slurry in a single pass. The filters for these characterization tests were selected based on the silica-a slurry properties such as mean particle size and LPC, abrasive type, wt % solids, and application requirements including target retention level, flow rate, allowable Δp and expected filter lifetime. 4 This study shows that the tested 1.5 μm rating POU and 5. μm distribution loop filters are suitable for filtration of this silica slurry formulation. However, if the slurry is expected to see a very large number of turnovers before usage, a more open 7. μm nominal rating Planargard CMP7 may be employed for the distribution loop filtration. 15 1 5 Figure 2a. 15 1.1 5 Figure 2b..1 hour feed 5 hour filtrate - CMP5 Turnovers / hour = 34 1 1 Feed SLR1 filtrate 1 1 Figure 2. LPC for 5. μm CMP5 distribution loop depth filter and 1.5 μm multiple layer POU SLR1 filter in silica-a slurry. (a) Initial feed to distribution loop filter and filtrate from loop filter after five-hour recirculation, and (b) five-hour recirculated slurry feed to the POU filter and filtrate from POU filter. The results from the filtration tests of five-hour recirculated slurry using.5 μm and 1. μm depth filters are presented in Figure 3. The cumulative % retention of the particles.56 μm in single-pass tests using CS5, CMP1 and SLR1 was close to 55, 38 and 37 %, respectively. Typical single-pass target retention % may range from 3 to 9% in CMP slurry filtration. In some slurries, more than one pass through the filter may be essential to achieve the target retention level. However, it is important to note that extremely high retention level usually results in limited filter lifetime and very high Δp. In most real-life slurry filtration applications, the objective is to have a reasonably tighter retention of large particles with acceptable filter lifetime. The selection of filters for a specific slurry requires empirical study. Although prior experience with similar slurries may indicate the filter requirements, the results below demonstrate that the performance of a filter can vary greatly across slurries due to abrasive particle morphology, LPC, PSD, wt % solids, particle settling characteristics, and chemical content and nature of additives and oxidizers. 15 1 5 Figure 3a. 15 1.1 5 Figure 3b..1 Feed CS5 filtrate 1 1 Feed 1 1 Figure 3. LPC for.5 μm (CS5) and 1. μm (CMP1) nominal rating depth media filters in single-pass filtration test. ENTEGRIS, INC APPLICATION NOTE 3

Figures 4 and 5 show the filtration test results for CS5 and CMP1 filter media with silica-1, ceria-1 and alumina-1 slurries. The feed PSD data show large differences as may be expected from different slurries. The filters effectiveness in reducing LPC shows considerable variation across the three slurries. For example, the CS5 filter seems to be very effective in removing large particles from the alumina-1 slurry, but less so for the ceria-1 slurry, despite both slurries having comparable low wt % solids. The silica-1, ceria-1 and alumina-1 slurries source samples were measured to have ~8 1, 5 24 1 5 and 13 1 5 particles/ml (for size.56 μm), respectively, suggesting that these ceria and alumina slurries have close to 3 and 17 times, respectively, higher number of particles as compared to the silica slurry. Also, the silica-1, ceria-1 and alumina-1 slurries source samples were found to have ~1.4 1 5, 73 1 5 and 8.2 1 5 particles/ml (for size 1. 1 μm), respectively. The resulting LPC reduction, Δp and flow rate for each filter media are summarized in Table 1. The Δp and flow rates were obtained for the filters at 1 minutes after start of filtration tests. The experimental uncertainty in the measurement of LPC, flow rate and pressure drop measurements is estimated to be ±5%, ±1 ml /min and ±.5 psi, respectively. The LPC reduction is presented in terms of % cumulative reduction of.56 μm particles for CS5 (.5 μm rating) and 1.1 μm particles for CMP1 (1. μm rating) filters. There are considerable differences in filter performance across the different slurries for CS5 as well as CMP1 filters. As seen in Table 1, alumina-1 and alumina-2 slurries with similar low % wt solids of abrasives showed similar retention and flow rate for CS5 media. A similar result of alumina-1 and alumina-2 slurries was seen for CMP1 filter. For CS5 media, silica-2 with similar wt % solids as silica-1, showed lower retention, much higher Δp and lower flow rate. Also for CS5, alumina-1 with similar wt % solids as ceria-1 resulted in much higher retention as well as higher Δp and a slightly lower flow rate. The LPC retention seen in ceria-1 is much lower than alumina-1 for CMP1 filter. 5, 4, 3, 2, 1, Figure 4a. 2, 15, 1, 5, % Retention Target = 75 (Cum. # > =.56 micron) % Ret. Achieved = 78 Feed Silica-1 CS5 filtrate.1 1 1 % Retention Target = 75 (Cum. # > =.56 micron) % Ret. Achieved = 56 Feed Ceria-1 CS5 filtrate.1 1 1 Figure 4b. 1, 8, 6, 4, 2, % Retention Target = 75 (Cum. # > =.56 micron) % Ret. Achieved = 88 Feed Alumina-1 CS5 filtrate.1 1 1 Figure 4c. Figure 4. LPC for.5 μm (CS5) nominal rating depth media filters in single-pass filtration experiments. (a) Silica-1, (b) Ceria-1 and (c) Alumina-1 slurry. 4 APPLICATION NOTE ENTEGRIS, INC.

5, 4, 3, 2, 1,.1 1 1 Figure 5a. % Retention Target = 5 (Cum. # > = 1.1 micron) % Ret. Achieved = 63 Feed Silica-1.1 1 1 Figure 5b. 2, 15, 1, 5, 1, 8, 6, 4, 2, % Retention Target = 5 (Cum. # > = 1.1 micron) % Ret. Achieved = 53 Feed Ceria-1 % Retention Target = 5 (Cum. # > = 1.1 micron) % Ret. Achieved = 71 Feed Alumina-1.1 1 1 Figure 5c. Figure 5. LPC for 1. μm (CMP1) nominal rating depth media filters in single-pass filtration experiments. (a) Silica-1, (b) Ceria-1 and (c) Alumina-1 slurry. As expected, for CS5 as well as CMP1 filters the PSL bead challenge solution with negligible wt % solids as compared to slurries, showed lower retention, lower Δp and lower flow rates as compared to most of the slurries. The settling rate of various slurries 5 can be significantly different depending on the colloidal stability of the particles and their densities (e.g., silica, alumina and ceria abrasive densities are ~2, 4 and 8 g/cc, respectively). The mean particle size of the tested slurries ranged from 12 nm to 16 nm. These results demonstrate that filter media large particle retention, pressure drop and flow rate are strongly influenced by the chemical additives and abrasive characteristics in the slurry, and that empirical filter characterization and optimization is essential for current and next generation CMP slurries. TABLE 1. FILTERS SHOW LARGE SLURRY DEPENDENT VARIATIONS IN PERFORMANCE. Slurry/ Challenge CS5 (Cumulative % LPC reduction for particles.56 μm) Pressure Drop Δp (psi) Flow Rate (ml/min) Silica-1 78 4 127 Ceria-1 56 12.7 469 Alumina-1 88 19 45 Silica-2 9 28 275 Alumina-2 83 14 458 PSL Bead 62 11.8 5 Slurry/ Challenge CS5 (Cumulative % LPC reduction for particles 1.1 μm) Pressure Drop Δp (psi) Flow Rate (ml/min) Silica-1 63 7.8 423 Ceria-1 53 5.2 519 Alumina-1 71 3.5 535 Alumina-2 69 5.2 531 PSL Bead 36 4.4 535 ENTEGRIS, INC APPLICATION NOTE 5

Conclusion Current- and next-generation chemical mechanical planarization slurry filtration targets tighter retention of large particles at much smaller large-particle cutoff to achieve improved polishing performance. Graded density depth filters can be effectively used to manage large particle behavior in these slurries. Optimum filter design should consider slurry abrasive morphology and composition, chemical additives, large and mean particle distributions, wt % solids, viscosity, density, abrasive settling, pressure drop, flow rate, filter lifetime and cost of ownership. Large particle retention, flow rate and pressure drop across the filters in filtration tests using tighter graded density depth media show dramatically different behavior in the PSL bead challenge solution, and silica, alumina and ceria abrasive slurries, indicating that new CMP slurries filter optimization still remains empirical in nature. Acknowledgements The author would like to thank Tim Towle, Chintan Patel, Craig Lazinsky, Christopher Wargo and Dr. Bipin Parekh of Entegris for reviewing the original manuscript of this paper. References 1. Lee K.W., Liu B.Y.H., Aerosol Science and Technology, 1, pp. 147 161, (1982). 2. Spielman L., Goren S.L., Environmental Sci. and Technology, 2, pp. 279 287, (1969). 3. Singh R.K., Conner G., Roberts B.R., Solid State Technology, 11, pp. 61 66, (24). 4. Singh R.K., Patel C., Conner G., Towle T., Viscomi R., Federau M., Semiconductor Manufacturing, 6, pp. 7 84, (24). 5. Singh R.K., Roberts B.R., in Proc. of the 6th Int. CMP-MIC Conf., pp. 441 448, (21). Entegris, the Entegris Rings Design, Creating a Material Advantage, Planargard and Solaris are registered trademarks of Entegris, Inc. AccuSizer is a registered trademark of Particle Sizing Systems, Inc. MasterFlex is a registered trademark of Cole Palmer Instrument Company. Tygon is a registered trademark of St. Gobain Performance Plastics. ENTEGRIS, INC. Corporate Headquarters 129 Concord Road Billerica, MA 1821 USA Customer Service Tel. +1 952 556 4181 Customer Service Fax +1 952 556 822 In North America 8 394 483 www.entegris.com 214 Entegris, Inc. All rights reserved Printed in USA 4435-759ENT-214