Desorption of Hydrogen from Palladium Plating

Similar documents
DEVELOPMENT OF ELECTROLESS PROCESS FOR DEPOSITION OF ZN SILICATE COATINGS

The Seventh International Conference on Cold Fusion (ICCF-7). Vancouver, Canada, April (1998), ENECO, Inc., Salt Lake City, UT., p. 356.

CLEANING AND PREVENTION OF INORGANIC DEPOSITS IN PLATE HEAT EXCHANGERS USING PULSATING CURRENT

METAL FINISHING. (As per revised VTU syllabus: )

METHODS OF COATING FABRICATION

Corrosion Rate Measurement on C-Steel

Report On Adsorption/Desorption Studies of CO on PEM Electrodes Using Cyclic Voltammetry. Sethuraman, Vijay Anand

International Journal of Advancements in Research & Technology, Volume 3, Issue 7, July-2014 ISSN

Effects of Lead on Tin Whisker Elimination

Leena Das and Der-Tau Chin Department of Chemical Engineering, Clarkson University Potsdam, New York

DEPOSIT STRESS ANALYZER

HIGH THROUGHPUT STUDIES OF HYDROGEN EVOLUTION ELECTROCATALYST FOR WATER ELECTROLYSIS

Materials of Engineering ENGR 151 CORROSION ELECTRICAL PROPERTIES

CHAPTER 3 ELECTROPLATING OF FDM-ABS

Supporting Information. High Performance Platinized Titanium Nitride Catalyst for Methanol Oxidation

- Copper cyanide strike for steel - "Woods" Nickel strike for stainless steel - Activates to plate nickel on nickel chromium on chromium

ME 280 Lab #1. Lüders Strain Evaluation of Stress Concentration and Electrochemical Embrittlement of Spring Steel

Corrosion Protection. Ing. Petr Drašnar, Ph.D.

Via Filling: Challenges for the Chemistry in the Plating Process

Electro catalytic amorphous nickel alloy

HYDROGEN UPTAKE RATES FOR GRADE 12 TITANIUM IN HOT ALKALINE BRINE MEDIA

Corrosion and batteries

The Effect of Calcium Nitrite on the Electrochemical Characterization of 3003 Aluminum Alloys in Sea Water. H.Mogawer and R.Brown

HYDROGEN ABSORPTION INTO ALPHA TITANIUM ALLOYS

Electrochemical Detection of Pyocyanin in Nanochannels with Integrated Palladium Reference Electrodes

Tantalum Materials in the CPI for the Next Millennium

Extended Life Tantalum Hybrid Capacitor

Effects of Galvanic Corrosion on Au-Sn Plated Contacts in Electronic Cable Interconnect

Characterization of Oxide Film Formed on Ck45 Steel by Plasma Electrolytic Oxidation Method

Electroplating. Copyright 2016 Industrial Metallurgists, LLC

Hard Gold Plating vs Soft Gold Plating Which is Right for My Application? By: Matt Lindstedt, Advanced Plating Technologies

Chapter 16 Corrosion and Degradation of Materials

Sur-Tech A/S Surface Technology

Electrolytic deposition of Zn-Mn-Mo alloys from a citrate bath

High Temperature Gold Deposition from Acid Cyanide Baths

DEPOSIT STRESS ANALYZER

Electrochemical cells use spontaneous redox reactions to convert chemical energy to electrical energy.

Distribution Review. Corrosion Control. Corrosion Control Vocabulary. American Water College 1. Corrosion Control Training Objectives

liquid catalyst in a solution gas catalyst in the gas phase

Standard Test Method. Impressed Current Laboratory Testing of Aluminum Alloy Anodes

D.T.D.939. Ministry of Defence Defence Procurement Agency, ADRP2 Abbey Wood Bristol BS34 8JH OBSOLESCENCE NOTICE

Electroplating, Anodizing & Metal Treatment Hand Book

ppm Dissolved Oxygen Measurement

Electroplating, Anodizing & Metal Treatment Hand Book

SIGNIFICANCE OF HYDROGEN EVOLUTION IN CATHODIC PROTECTION OF STEEL IN SEAWATER

Cu(I)-Mediating Pt Reduction to Form Pt-Nanoparticle-Embedded Nafion Composites and Their Electrocatalytic O 2 Reduction

Dr.RAVINDER KUMAR B.E.( Hons.), M.E., Ph.D. 1 Dr.Ravinder Kumar

Three-dimensional NiFe Layered Double Hydroxide Film for Highefficiency

CHEMICAL SPECIFICATIONS OF ZINC AND ZINC ALUMINUM ALLOYS: TABLE 1 TABLE 1

PALLAMET 500 Palladium-Nickel

Corrosion Control and Cathodic Protection Data Sheet

In Situ Studies of Passive Film Chemistry using X-ray Absorption Spectroscopy

DuPont Riston Special FX Series - FX515

Calculation of the Amount of Hydrogen Absorbed by Steel During the Mechanical Plating Operation

CORROSION & ITS CONTROL -Content. Introduction Classification Galvanic series Factors affecting Protection methods Summary

A Novel Electrodeposition Process for Plating Zn-Ni-Cd Alloys

Platinum Nanostructures by Template Wetting Nanofabrication and Their Use in a Miniature Fuel Cell Membrane Electrode Assembly

Preparation of porous manganese hydroxide film and its application in supercapacitors

Proposal for high performance corrosion resistance processes

ELECTROCHEMICAL PROPERTIES OF CoCl 2 (PPh 3 ) 2

ELECTROCHEMICAL SYNTHESIS OF POLYPYRROLE (PPy) and PPy METAL COMPOSITES ON COPPER and INVESTIGATION OF THEIR ANTICORROSIVE PROPERTIES

Corrosion of Metals. Industrial Metallurgists, LLC Northbrook, IL Copyright 2013 Industrial Metallurgists, LLC

Yajuan Liu a, Jinyong Xu a, Ying Gao b, Ye Yuan b, Cheng Gao a

Electrochemistry Written Response

Approaching zero discharge: in plant evaluation of zinc thermal diffusion coating technology, phase I

NATIONAL BUSINESS AND TECHNICAL EXAMINATIONS BOARD (GENERAL EDUCATION EXAMINATION) MAY/JUNE 2007 SECTION B CHEMISTRY (ESSAY) TIME: 1 HOUR 40 MINUTES

Galvanic corrosion evaluation of 6061 aluminum coupled to CVD coated stainless steel Elizabeth Sikora and Barbara Shaw 6/9/2016

Studies on Alloys and Composites that Undergo Anomalous Codeposition

Supporting Information

M.N.Singh, D.K.Basu, A.K.Bhattmishra and S. K.Narang CORROSION RESISTANT ELECRODEPOSITED ZINC COATING FROM ZINC DROSS

Supporting Information

Technical Paper. Tyco Electronics HM-15 Lubricant Stability Projected Weight Loss. Gregory T. Pawlikowski, Ph. D. Tyco Electronics Harrisburg, PA

Heat Transfer Simulation to Determine the Impact of Al-5Mg Arc Sprayed Coating onto 7075 T6 Al Alloy Fatigue Performance

Heng-Pan Yang, Sen Qin, Ying-Na Yue, Li Liu, Huan Wang* and Jia-Xing Lu**

DURABILITY of CONCRETE STRUCTURES

Supporting Information

Development of Corrosion Probe based on Solid State Reference Electrodes 1 Introduction

Study of Electrochemical Polishing Applications in some alloys to obtain high surface finish

SCC Initiation for X80 Pipeline Steel Under AC Application in High ph Solution

EVALUATING MITIGATION METHODS FOR CHLORIDE INDUCED CORROSION OF REINFORCED CONCRETE STRUCTURES

Module 4 : Hydrogen gas. Lecture 29 : Hydrogen gas

Electrodeposition Behaviors of Zn-Ni Alloy on Copper Foil with Carrier

CORROSION of Metals CORROSION CORROSION. Outline ISSUES TO ADDRESS... Why does corrosion occur? What metals are most likely to corrode?

Angel International School - Manipay 1 st Term Examination November, 2017

Cold Fusion at ENEA Frascati: Progress Report

Lecture 16: Surface Processing

NASF SURFACE TECHNOLOGY WHITE PAPERS 81 (5), (May 2017) 4 th Quarterly Report October-December 2016 AESF Research Project #R-118

Kinetic Characteristics of Different Materials used for Bolting Applications

STATE OF ILLINOIS WILLIAM G. STRATTON, Governor

The effect of 180 C-annealing on the electrochemical behavior of nano-thick zinc-electroplated copper in aqueous solutions with different ph

IPC TECHNICAL PAPER SERIES NUMBER 74 LOCALIZED CORROSION OF STAINLESS STEELS IN PAPER MACHINE WHITE WATER DAVID F. BOWERS FEBRUARY, 1979

Direct Copper Metalization of Aluminum: Elimination of Zincate

Australian Standard. Electroplated coatings of rhodium for general engineering applications AS AS 2429

Application Note CORR-4

How to achieve uniform thickness of the anodic aluminum oxide film? Leonid M. Lerner AlZi Anodizing Solutions Co.

The Deposition Characteristics of Accelerated Nonformaldehyde Electroless Copper Plating

Selection criteria for Biomaterials

Thermogravimetric Thin Aqueous Film Corrosion Studies of Alloy 22; Calcium Chloride Solutions at 150 C and Atmospheric Pressure

Direct Electroless Silver Plating on Copper Metal from Succinimide Complex Bath Using Imidazole as the Reducing Agent

Tutorial Corrosion II. Electrochemical characterization with EC-Lab techniques

Transcription:

Desorption of Hydrogen from Palladium Plating I-yuan Wei Jerry Brewer AMP Incorporated ABSTRACT Desorption of co-deposited hydrogen from Pd and Pd alloy platings may cause micro-cracking. The desorption process takes days to complete. To assure that hydrogen induced micro-cracking can be detected immediately after plating, several methods have been established for quick removal of hydrogen from Pd deposits. INTRODUCTION During plating of Pd or Pd alloy from an aqueous electrolyte, hydrogen is generated on the cathode if the plating efficiency is less than 100%. Hydrogen is co-deposited and diffuses into the Pd metal lattice forming an interstitial solid solution 1 of PdH x. Pd has a face centered cubic sublattice. Hydrogen atoms partially fill the octahedral holes to form PdH x. The fraction of interstitial sites occupied depends on the plating conditions such as temperature, partial pressure of hydrogen, etc. Although hydrogen atoms occupy only interstitial sites, the sublattice of metal atoms in PdH x is larger than and simply an expansion of the parent metal lattice. The PdH x lattice undergoes expansion or contraction as the Pd/H ratio changes. Palladium metal has a lattice constant of 3.889 Å. If hydrogen is dissolved in Pd at room temperature, the lattice will increase gradually until an atomic ratio for H/Pd of 0.03 is reached. At this ratio, the PdH x is entirely in the a-phase and the lattice constant has increased to 3.893 Å. A higher hydrogen concentration will transform some of the a-phase to b-phase, which has a lattice constant of 4.04 Å and a H/Pd ratio of 0.57. 2 Accordingly, the lattice constant of Pd plating is influenced by the amount of co-deposited hydrogen. It is known that Pd plating with high hydrogen concentration causes micro-cracking. 3 This can be explained by considering the difference in lattice constants of pure Pd, and the hydrogen containing a- and b-phases. The desorption of hydrogen from Pd plating must be expected to cause stresses in the plating because of the lattice contraction, especially during transformation from b-phase to a-phase. When the tensile components of this stress exceed the yield point the stress is relieved by cracking. To estimate a time interval for the onset of the stress relief, diffusion of hydrogen in palladium may be considered. The corresponding diffusion constant at room temperature 4 is about 5.4 10-7 cm 2 s -1. At this relatively high diffusion rate one should expect a very short transit time of a change in concentration of hydrogen across a Pd layer of a few µm. However, according to the experience of the authors residual hydrogen may not have been completely desorbed from Pd platings after days or even months. Trace impurities in the deposit, surface conditions and the mass transfer coefficient of hydrogen from the layer to the environment affect the diffusion process. Therefore, hydrogen induced micro-cracking may or may not be occurring immediately after plating. Among the detrimental consequences of micro-cracking are poor adhesion, poor wear and high porosity. Therefore, it is highly desirable to find practical methods for accelerated removal of hydrogen from Pd deposits. In the study leading to this paper possibilities of identifying such procedures the following approaches were taken: x Constant potential coulometry for the determination of the H/Pd atomic ratio, x cyclic voltammetry, x anodic polarization, x vacuum extraction at elevated temperature, x vapor phase desorption. EXPERIMENTAL The instrument used to control current and potential for the experiments performed in this study was an EG&G PARC rcopyright 2004 Tyco Electronics Corporation. All rights reserved. AMP Journal of Technology Vol. 5 June, 1996 I. Wei and J. Brewer 49

model 173 potentiostat/galvanostat. Experiments involving constant potential were carried out using a model 173 with an EG&G PARC model 179 digital coulometer plug-in module. Cyclic voltammetry experiments used the model 173 with an EG&G PARC model 175 universal programmer and a model RE0074 X-Y recorder. The test cell for both types of experiments was an EG&G PARC model K0047 corrosion cell with a model 178 electrometer probe and 178/41 filter. All required specimens were prepared following the same general procedures. Copper research test paddles with an effective surface area of 10 cm 2 served as substrates. The test paddle surface was first degreased in alkaline cleaner, rinsed in deionized water, electropolished in 10% sulfuric acid and rinsed again with deionized water. For constant potential coulometry the samples were air dried and weighed on a Sartorius model 2472 analytical balance. For the cyclic voltammetry tests this step was not performed. The sample was then plated in a palladium strike bath at room temperature for 45 s at a current density of 1 A/dm 2. The sample was then rinsed in deionized water and plated in a proprietary palladium bath. For a pre-calculated duration the current density was chosen to achieve a thickness of 1.9 µm. The sample, after removal from the Pd bath, was rinsed in deionized water and air dried. The solution in the K0047 corrosion cell was 1N sodium hydroxide for all experiments. All potentials reported in this study are referred to the saturated calomel electrode (SCE). The vacuum extraction experiments were performed in a Precision Scientific Company Thelco model 19 vacuum oven, which provided a pressure of 62 mm Hg (8.266 kpa). A Hybrid Technology Corporation Phase Four Vapor Phase Reflow system was used for the vapor phase desorption experiments. The system used 3M Fluorinert Electronic Liquid FC-70. It raises the temperature of the part to 215 C. RESULTS Constant Potential Coulometry for the Determination of the H/Pd Atomic Ratio The samples for this part of the study were weighed and then plated in the palladium strike bath at room temperature and a current density of 1 A/dm 2 for 45 s. Plating conditions were varied to determine how, particularly bath temperature and current density, affect the amount of hydrogen in the deposit. The palladium bath was first tested at 20 C and current densities of 1, 2, and 3 A/dm 2. Then the bath temperature was raised to 60 C, and samples plated at 1, 3, 6, and 10 A/dm 2. Subsequently the bath temperature was increased to 75 C and tested at 1, 3, 6, and 9 A/dm 2. All samples were plated to a thickness of 1.9 µm. At each current density three individual specimens were prepared. Each Pd-plated sample was then placed in the K0047 corrosion cell and anodized for 15 min at a potential of 10.750 V. The total electric charge, measured in coulombs (C; 1C51 s A), that passed during this time was recorded with the model 179 digital coulometer. After anodization, the sample was removed from the corrosion cell, rinsed in deionized water, air dried and weighed. From the charge passed and the mass of palladium plated, the atomic ratio of H to Pd was calculated. In Table 1 the experimental parameters temperature and current density are listed together with the H/Pd atomic ratios. The latter are averages of the three samples for each current density. Table 1. Atomic ratio H/Pd for palladium platings prepared at different temperatures and different current densities. Bath Temperature C Current Density A/dm 2 Atomic Ratio H/Pd 20 1 0.212 6 0.010 2 0.160 6 0.008 3 0.165 6 0.002 60 1 0.016 6 0.002 3 0.144 6 0.005 6 0.122 6 0.005 10 0.082 6 0.002 75 1 0.005 6 0.002 3 0.101 6 0.035 6 0.104 6 0.011 9 0.118 6 0.002 Cyclic Voltammetry The procedure employed for this technique involved measuring the corrosion potential of a sample in a 1N sodium hydroxide solution and then scanning from a potential that was 100 mv more negative to a potential that was 1 V more positive than the corrosion potential and then back again while measuring the current carried by the cell. This cycle was repeated at least five times. The instruments for the various tasks are listed in Table 2. Table 2. Instruments used for carrying out the tasks required for cyclic voltametry. Instrument Task 175 Universal Programmer to scan the potential 173 Potentiostat/Galvanostat with 376 Logarithmic Converter Module to measure corrosion potential and current RE0074 X-Y Recorder to record output of scanning When a sample of pure Pd was tested with this technique, no current passed through the cell. The corresponding scan is shown in Figure 1. Until the onset of oxygen evolution above a potential of 10.650 V no current is noticed. The same result was obtained on a two year old palladium plated part. In none of these samples hydrogen was expected. The results of the scan support this expectation. In the previous section it was mentioned that the palladium surface with the highest amount of hydrogen had been plated at a bath temperature of 20 C and a current density of 1 A/dm 2. Figure 2 shows the cyclic scan for a sample plated under these conditions. A high current is carried during the first anodic scan. It decreases with increasing number of scans until it reaches a value of virtually zero. The results obtained here show that this technique can be used to determine the presence of hydrogen in a plated deposit. As the sample is anodized, it is observed that less and less hydro- 50 I. Wei and J. Brewer AMP Journal of Technology Vol. 5 June, 1996

in the experimental section. They were plated to a thickness of 1.9 µm in the palladium bath at 20 C and at a current density of 1 A/dm 2. Subsequently each sample was rinsed and placed in the K0047 corrosion cell. A constant potential was applied to the sample for a set time after which it was shut off. A cyclic voltammetry scan was then performed on the sample. Figure 3 shows the anodizing potentials, the time periods, and the corresponding cyclic voltammogram. It can be seen that with increasing anodizing potential and duration a scan pattern is approached that appears to be identical to the scan of pure Pd. This was obtained at an anodizing potential of 10.750 volts for 90 minutes. Figure 1. Cyclic voltammetry on pure Pd foil and aged palladium plating. Figure 3. Voltammetry after anodization in 1N NaOH. Figure 2. Cyclic voltammetry on fresh palladium plating prepared at 20 7C, 1 A/dm 2. gen remains. This is in agreement with the results from the procedure used to determine the H/Pd atomic ratio. Because of these results from this point on the cyclic voltammogram was used to determine if other procedures had fully removed the hydrogen in the deposit. Anodic Polarization In the first two sections of this study two analytical methods were introduced: (a) a method for quantitative determination of the H/Pd atomic ratio. (b) a method for qualitative determination of presence of hydrogen in a Pd deposit. It can be anticipated that, by combining the two processes, samples with low hydrogen content can be prepared in a short period of time. These samples would be expected to compare to older plated parts which had their hydrogen slowly escape over a long period of time. Anodic polarization offers an opportunity to remove the hydrogen from the deposit and cyclic voltammetry to determine how effective the anodic polarization had been. Samples were prepared using the standard procedure described Vacuum Extraction at Elevated Temperature This procedure was employed with the intent to remove the hydrogen from the deposit with vacuum and elevated temperature serving as driving forces. Again, samples were prepared following the standard procedure with the palladium bath at a temperature of 20 C and at a current density of 1 A/dm 2. After plating, the samples were rinsed and air dried. They were then placed in the vacuum oven which was already set at the desired temperature. The oven was closed, the vacuum applied and the time scale set to zero. Temperature and duration of exposure of the samples to the vacuum were varied. Two different temperatures, 100 C and 150 C, and several intervals of exposure time were chosen. After the desired duration of exposure had elapsed, the samples were removed from the oven, placed in the K00477 corrosion cell and cyclic voltammograms were obtained. Figure 4 shows results of exposure of a sample to vacuum at 100 C for 60 minutes and at 150 C for 90 minutes. A noticeable amount of hydrogen is still present in the sample treated at 100 C for 60 minutes. The cyclic voltammogram of the sample exposed to 150 C in vacuum for 90 minutes is identical with that for pure Pd. To determine how effective the treatment in vacuum was, three samples were placed in the oven. Without applying vacuum the samples were heated to 150 C and left at this temperature for 150 min. The results of this test presented in Figure 4 show clearly that all three samples still contain hydrogen. Vapor Phase Desorption For this experiment three samples were prepared in the palladium bath at a temperature of 20 C and a current density of 1 AMP Journal of Technology Vol. 5 June, 1996 I. Wei and J. Brewer 51

reaction i.e. the reduction of H 1 to neutral hydrogen is negligible. With increasing number of scans the current decreases until its value coincides with the base line. It was demonstrated that cyclic voltammetry can be used explicitly to monitor removal of hydrogen. Therefore, the method was also applied to evaluate other techniques that appear potentially useful for hydrogen desorption. Figure 4. Voltammetry after air and vacuum extraction. A/cm 2. The samples were rinsed with deionized water, air dried and placed in the Hybrid Technology Corporation Phase Four Vapor Reflow system for 5 minutes. After their removal from the vapor phase reflow unit, cyclic voltammograms were obtained. They are presented in Figure 5. The scans for all three samples are identical and are also the same as found on pure Pd metal and on the two-year old plated samples. Two of the three samples had palladium flaking off in form of a very fine powder. This test yielded samples with no hydrogen in the deposit and induced cracking in two of them. Such behavior is expected with age removal of hydrogen. Electrochemical oxidation of hydrogen in palladium at a potential of 0.59 V relative to the SCE was reported previously. 2 In order to accelerate the anodization, for the present study the potential was set slightly higher, namely to 10.75 V. The amount of hydrogen can be calculated from the total charge Q, which in turn is found by integrating over the current Q 5 e 0 t i(t)dt where i(t) 5 current as function of time, t 5 duration of current flow. Estimated values of the partial pressure of H in PdH 0.03 and PdH 0.1 are listed in Table 3 for temperatures of 50, 160, and 200 C. 5 These data show that with increasing temperature the removal rate of hydrogen from palladium deposits should also increase. Results of the study presented here and already reported above confirm this. It was found that at 150 C an exposure for 120 minutes is needed to complete the hydrogen removal under vacuum. This was reduced to 5 minutes at 215 C under a perfluoro-hydrocarbon vapor shield. Table 3. Estimated values of partial pressure of hydrogen for two PdH x solid solutions at three different temperatures. 5 Figure 5. Cyclic voltammetry on sample after 5 min vapor phase treatment. Partial Hydrogen Pressure Composition Temperature C mm Hg kpa PdH 0.03 50 1.6 0.213 160 320 42.663 200 500 66.661 PdH 0.1 50 24 32.424 160 1000 133.322 200 2600 346.637 DISCUSSION The term cyclic voltammetry describes a variant of voltammetry whereby the potential is scanned periodically between two limits. In this study, the limits were selected only for observing oxidation and reduction of hydrogen. The data obtained by this method were verified by comparing them with data measured on samples of cast, of two-year old plated and of freshly plated palladium. As shown in Figures 1 and 2 a noticeable current was observed only on the fresh samples. Because the neutral hydrogen atoms are oxidized to protons which diffuse rapidly to the bulk of the solution, the reverse An important result of this study was that hydrogen did not desorb from Pd deposits if exposed to air at elevated temperature. Vacuum or a perfluoro-hydrocarbon vapor shield were shown to be essential for thermally activated desorption. A reasonable explanation of this observation is that the presence of water vapor in air combined with the catalytic nature of a Pd surface inhibits desorption of hydrogen from the deposit. SUMMARY AND CONCLUSIONS The results of experiments presented in this study show that the following four methods are suitable for accelerated removal of hydrogen from palladium plated samples. 52 I. Wei and J. Brewer AMP Journal of Technology Vol. 5 June, 1996

1. Cyclic voltammetry in 1N NaOH at a potential varying from 20.1 to 1.0 V relative to SCE. 2. Anodic polarization in 1N NaOH for 2 hours at a potential of 10.75 V relative to SCE. 3. Vacuum extraction at 150 C for 2 hours. 4. Vapor phase desorption at 215 C for 5 minutes. Application of any of these methods resulted in a drastically reduced hydrogen content of newly palladium plated samples. The hydrogen content after such treatments was equivalent to the hydrogen content of pure Pd metal or to that of two year old palladium plated parts. a All four methods offer the opportunity to remove hydrogen from a palladium deposit. Thermally activated extraction in vacuum and vapor phase desorption methods appear to be most suitable in a production environment. Application of each of the four methods presented in this study can contribute to negating the statement that hydrogen embrittlement must be expected to occur after palladium plated products are shipped. Some of the methods have been in use since 1985. They proved to provide consistent microcrackingfree products and allowed shipment of billions of electronic contacts without any concern of delayed microcracking. REFERENCES 1. D.G. Westlake, C.B. Satterthwaite and J.H. Weaver, Physics Today 31, 32 (1978). 2. H.D. Hedrich and Ch.J. Raub, Metalloberfläche 31, 512 (1977). a The samples used in this study were entirely Pd plated. Because of the mixed potentials that would exist if selectively plated parts were used cyclic voltammetry and anodic polarization appear to be not suitable for such parts. 3. Ch.J. Raub, Platinum Metals Rev., 26, 158 (1982). 4. G. Alefeld and J. Völkl (editors), Hydrogen in Metals II (Springer Verlag 1978), p. 145. 5. F.A. Lewis, The Palladium Hydrogen System (Academic Press, London, 1967), p. 14. I-Yuan Wei is AMP Consultant and Director, Contact Materials, in the Global Technology Group at AMP Incorporated, Harrisburg, Pennsylvania. Dr. Wei holds a Bachelor of Science degree in chemistry from the National Taiwan Normal University, a Master of Science degree in organic chemistry from the National Taiwan University, and a Ph.D. in physical chemistry from Tufts University. He held positions as research and development manager at National Aluminum, as Scientist at Sprague Electric Company, and as Research Associate at the University of North Carolina at Chapel Hill. In 1981 he joined AMP as a Senior Development Engineer and served the Company in positions with increasing responsibilities as Project Manager, Manager Plating Research, and as Director, Contact Materials. During 1991 to 1994 Dr. Wei was chairman of the Electronics Finishing Committee of the American Electroplaters and Surface Finishers Society and received the Board Recognition Award of the Society in 1994. He is credited with the introduction of the Duragold plating process and is recognized for his contributions to the evaluation of non-precious metals as gold replacements. His present research interests focus on new contact finishes and finishing processes. Jerry Brewer was a member of the Technology Group of AMP Incorporated when the work reported above was done. AMP Journal of Technology Vol. 5 June, 1996 I. Wei and J. Brewer 53