AVM System 500. Aussie Membrane 500

Similar documents
AVM System 500. Aussie Membrane 500

Delivery, Storage, and Handling

Aussie Skin 550. Heavy Duty Below Grade, Blind-Side, Under-Slab Waterproofing Membrane. Delivery, Storage, and Handling

Aussie Skin 550. Heavy Duty Below Grade, Blind-Side, Under-Slab Waterproofing Membrane. Delivery, Storage, and Handling

Division 7-Moisture Protection Section 7-Under Tile Waterproofing Exceeds ANSI A Rev. 05/2012 Page 1

8245 Remmet Ave Canoga Park, CA (888) Installation Instructions - AVM System 700 Under Tile Waterproofing and Anti-Fracture Membrane

AVM Drain Board 2000/2020

SECTION SELF-ADHERING SHEET FLASHING

DAYSONFAST Table of Contents

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

SECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING

"WE CAN AGUASEAL THAT" AGUASEAL WATERPROOFING SYSTEMS A G U A B A S E

SECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

BITUTHENE Deck System

Pol-E-Base Modified Bitumen Roof System

WPM WATERPROOFING MEMBRANE

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION

Pacific Polymers Elasto-Mat D&G Guide Specification

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

BAYBLOCK HT/BAYBLOCK HT BASE

FireShield Restoration Specifications - EPDM

Pacific Polymers Elasto-Deck 5000MR Guide Specification

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

900HA is a two component, hand-applied seamless liquid waterproofing that is typically foottrafficable

ASTEC Re-Ply Roof System for ASPHALT & MODIFIED BITUMEN ROOFS

GUIDE SPECIFICATION FOR MEL-ROL : ROLLED, SELF-ADHERING WATERPROOFING MEMBRANE

PEKAY T570 RUBBERSEAL

SECTION SELF-ADHERING SHEET MEMBRANE WATERPROOFING

Instruction Guide APPLICATION OF CIM TO CONCRETE

Westbuild PRO. Rapid Drying Wet Area Waterproofing. Polyurethane (PU) modified, permanently flexible, rapid drying, class III waterproof membrane.

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

Student Services & Classroom Addition

DESCRIPTION FEATURES AND BENEFITS AREAS OF USE. Showers & Bathrooms. Balconies & Patios SUITABLE SUBSTRATES. for application on: Concrete & Masonry

A. The work of this section includes, but is not limited to, the following:

A. Supplier Qualifications: The ACRYSHIELD SPF Roofing System, as supplied by National Coatings Corporation, is approved for use on the project.

SECTION FLUID-APPLIED WATERPROOFING

Shower Waterproofing Membrane Under tile and wet area waterproofing membrane.

FLUID APPLIED WATERPROOFING

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing

***********************************************************************************

Traffic Bearing Membrane

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY

DIVISION 7 MARFLEX 5000 FLUID APPLIED AIR & VAPOR BARRIER - 3 PART SPEC 07262

SECTION TW-60 Self-Adhering Sheet Waterproofing Membrane

Pacific Polymers Elasto-Deck BT Guide Specification

A. Submit product data sheets and literature verifying fire ratings and physical properties of materials.

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

PROCOR Composite Waterproofing System

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

CIM IG 13 11/06. Instruction Guide

Section Pre-Applied Sheet Membrane Waterproofing

Master-Seal Surface-Applied Waterproofing System

ITEM 458 WATERPROOFING FOR STRUCTURES

Section COATING RESTORATION

2 COMPONENT LIQUID WATERPROOFING PART 1 GENERAL. A. Two component liquid waterproofing for positive side waterproofing on mineral substrates

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

Application Guide for. MasterSeal Roof 3500 (MasterSeal M 820 Membrane)

METHOD STATEMENT SIKALASTIC -680 AP SIKA LIMITED (VIETNAM)

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

80648R StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL

Rapid Re-coat PU Modified Under-tile waterproof membrane.

80648 StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

Centenary United Methodist Church January Code Improvements & North Entry Remodel Beatrice, Nebraska ADDENDUM NO. 1

THE BRITE THING TO DO

TOPCOAT System Specifications Corrugated Transite Panels

URETHANE. CONCRETE ROOF WATERPROOFING SYSTEM Sample Design Guideline

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

AFM Anti-Fracture Membrane & AFM-WM Anti-Fracture Waterproofing Membrane Three-Part Specifications

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

PROTECTO DECK INSTALLATION INSTRUCTIONS

ERSYSTEMS OneStep Plus

SECTION ANTI-FRACTURE MEMBRANE UNDERLAYMENT

AQUATITE. Also designed as: Crack/gap filler for masonry and unglazed ceramics Sealants against leaks Repairer for roof cracks and gutters

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

A Design Review of Waterproofing Codes

SECTION SELF-ADHERING SHEET WATERPROOFING CCW-711

Copolymer BEFORE. Copolymer DURING. Copolymer AFTER. (800) TRI-CHEM 3

Desmopol Application Guide for Corrugated Asbestos Roofs

Section COATING RESTORATION

ARDEX GUIDE SPECIFICATION ARDEX TRM Transportation Repair Mortar Fast-Setting Concrete Repair Mortar

MasterSeal HLM Liquid cold-applied elastomeric waterproofing membrane system

Desmopol Application Guide onto Ply/OSB Deck

GUARANTEED ASPHALT LIMITED

80648R StoCoat Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Permaroof 500 Liquid Membrane application onto:- Corrugated asbestos roofs

BITUTHENE 3000 and BITUTHENE Low Temperature Below-Grade

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING

80212R StoColor Lastic Acrylic-Based, Elastomeric Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Data Sheet Eco-Smart Membrane WS M1

Section Pedestrian Traffic Coatings

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

Transcription:

Generic Spec TECH DATA SHEET Sections - 071000 / 071400 / 071416 ICC ESR-2503 L.A. RR#: 25550 Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections 071000 / 071400 / 071416 Fluid Applied Waterproofing Product Name Manufactured by 888.414.1041 818.888.0050 Product Description The AVM is a Water- Based rubber/bitumen liquid membrane modified with high performance rubberized polymers giving it excellent adhesion, which dries to a tough, black seamless flexible waterproof membrane. The Aussie Membrane 500 is a single component thixotropic coldapplied bitumen paste that exhibits excellent elongation and recovery properties. The AVM has excellent longterm stability (maintains its properties over very long periods of time) un-like other below grade systems (including polyurethane based systems) that Crack and become brittle as they age. Where to Use Retaining Walls: Waterproof below-grade, concrete, block walls, basements, etc. Planters: Waterproof planters and other landscaping features. In-between slab waterproofing: To provide a sandwich membrane in-between two concrete slabs or over wood decks that will receive a topping slab. Also used as an under-tile membrane when a mud-bed or thick-set type assembly is required. Warranty AVM Industries will warranty the installed membrane for a period of five (5) years. Ten (10) year warranties are also available. For complete warranty details, contact AVM Industries or consult with your applicator. Delivery, Storage, and Handling a. Delivery of all the materials to the job site must be in their original sealed containers, with manufacturer s name and label intact. b. Handle and store containers in accordance with printed instructions. c. Store at temperatures between 50 F and 90 F. Do not store materials in direct sunlight or where they may be damaged by water or rain. d. Failure to comply with the recommended storage conditions may result in premature deterioration of the product. For specific storage advice, please contact AVM Industries and/or its representatives. e. Keep all materials out of the reach of children. f. If irritation occurs during use, liberally flush affected areas with water. If irritation continues, see a physician immediately. Project Conditions 1. All surfaces to which the Aussie Membrane 500 is applied to must be sound and stable, with an even finish and free from dust, loose debris, grease, curing agents, etc. 2. The may be applied to damp but not waterlogged surfaces (Green Concrete) 3. Do not apply materials at temperatures below 40 F and falling or if precipitation is imminent. Do not apply materials in direct sunlight at temperatures above 100 F or rising. 4. Warn personnel against hazards of materials to skin and eyes. Note other hazardous conditions on the job that might require special protective gear and or any other special protective or safety procedures. 5. Protect adjacent surfaces which could be damaged during the application procedure. 6. This system must not be used to cover Expansion Joints. System Application Read the Installation Instructions Prior to Installation. Application instructions vary based on type of application and the type of surfaces it s being applied to. For specific application procedures, refer to, or download the appropriate installation instructions. (For Retaining Walls, refer to the Retaining Walls Installation Instructions. For Planters, refer to the Planters Installation Instructions, etc.) Basic installation procedures are also provided in the Spec Data Sheet of each type of installation. For a complete/comprehensive set of instructions, however, please refer to the Installation Instructions documents. Quality Control a. Visually inspect all coated surfaces to ensure a full and proper coating application, especially at corners, drainage footings and other hard-to-reach areas. b. All unsatisfactory areas shall be repaired prior to final acceptance. Protection of Installed Work a. The completed section shall be protected for the first 24 hours after application or until the surface is sufficiently cured. (The amount of drying time may vary depending on temperature and humidity conditions) b. Always protect the waterproofing from possible damage. Use AVM Foam Board, AVM Drainage Boards or AVM Approved Protective Panels. Refer to the spec Data Sheets or to the Min Thickness Table for protection details. Availability and Cost Contact AVM Industries or your approved applicator for pricing and availability. Technical Services Technical services are available by contacting our offices at: 888.414.1041 or 818.888.0050 or visit System Specifications See next page. Tech Data Sheet Rev. 09/2017 1/2 AVM Document # 30500-Generic

The following coverages are based on controlled tests. Actual coverages may vary. Technical Information Color Specific Gravity Coverage: (Varies depending on substrate) Flash Point Service Temperature Application Temperature Dark brown. After drying: black 1.189 gr/cm2 24 25 sq.ft./gal. @ 60 Dry Mills Non-flammable 15ºF-177ºF (-10ºC to +80ºC) 42ºF-132ºF (+5ºC to 55ºC) Solid Content 64% Tensile Strength >15.4 Lbs (>7 kg) ASTM D 412 Elongation at break >1000% ASTM D 412 Resistance to water pressure 1 tm 24 hr Passed ASTM D751 Water vapor transmission 4.0 gr/m2 24 hr ASTM D 96 Recovery 85% IS 1536 Creep At 177ºF (80ºC) No Creep DIN 52123 Resistance to Standing Water Passed ASTM D 2939 Bacterial Attack in soil 30 days @ 105ºF (40ºC) Passed ASTM D 2939 Crack bridging >3/16" (>5mm) IS 1731 Certifications ISO 9002, Green Label, I.Q. Net (International Certification Network) Item / Component Packaging Approx Shipping Weights VOC AVM Primer 500 2.0/5.0 gal. pails 2.0/5.0 gal. 15/39 lbs. 15 Grams/Liter AVM 5.0 gal. pails 5.0 gal. 52.5 lbs 19 Grams/Liter Retaining Wall with Aussie Membrane In-Between Slab Waterproofing Retaining Wall Concrete Slab Aussie Membrane Topping Slab Cant Strip Aussie Membrane Footing Block Walls with Aussie Membrane Planter with Aussie Membrane Aussie Membrane Aussie Membrane Block Wall Protection Board Block Wall Drainage Board Aussie Membrane Planter Wall Drainage Board Dirt Cant Strip Drainage Pipe Cant Strip Drainage Pipe Slope to Drain Footing Footing Drain For a complete list of details in CAD or PDF, please visit our website at. 888.414.1041 818.888.0050 Quality Waterproofing Products Tech Data Sheet Rev. 09/2017 2/2 AVM Document # 30500-Generic

Retaining Walls Spec TECH DATA SHEET Sections - 071000 / 071400 / 071416 ICC ESR-2503 L.A. RR#: 25550 Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections 071000 / 071400 / 071416 Fluid Applied Waterproofing Product Name Manufactured by 888.414.1041 818.888.0050 Product Description The AVM is a Water- Based rubber/bitumen liquid membrane modified with high performance rubberized polymers giving it excellent adhesion, which dries to a tough, black seamless flexible waterproof membrane. The Aussie Membrane 500 is a single component thixotropic coldapplied bitumen paste that exhibits excellent elongation and recovery properties. The AVM has excellent long-term stability (maintains its properties over very long periods of time) un-like other below grade systems (including polyurethane based systems) that Crack and become brittle as they age. Where to Use Retaining Walls: Waterproof below-grade, concrete, block walls, basements, etc. Warranty AVM Industries will warranty the installed membrane for a period of five (5) years. Ten (10) year warranties are also available. For complete warranty details, contact AVM Industries or consult with your applicator. Delivery, Storage, and Handling a. Delivery of all the materials to the job site must be in their original sealed containers, with manufacturer s name and label intact. b. Handle and store containers in accordance with printed instructions. c. Store at temperatures between 50 F and 90 F. Do not store materials in direct sunlight or where they may be damaged by water or rain. d. Failure to comply with the recommended storage conditions may result in premature deterioration of the product. For specific storage advice, please contact AVM Industries and/or its representatives. e. Keep all materials out of the reach of children. f. If irritation occurs during use, liberally flush affected areas with water. If irritation continues, see a physician immediately. Project Conditions 1. All surfaces to which the Aussie Membrane 500 is applied to must be sound and stable, with an even finish and free from dust, loose debris, grease, curing agents, etc.. 2. The may be applied to damp but not waterlogged surfaces (Green Concrete) 3. Do not apply materials at temperatures below 40 F and falling or if precipitation is imminent. Do not apply materials in direct sunlight at temperatures above 100 F or rising. 4. Warn personnel against hazards of materials to skin and eyes. Note other hazardous conditions on the job that might require special protective gear and or any other special protective or safety procedures. 5. Protect adjacent surfaces which could be damaged during the application procedure. 6. This system must not be used to cover Expansion Joints. System Application Read the Installation Instructions Prior to Installation. Application instructions vary based on application surfaces. Following are common (Generic) application procedures only. For specific application procedures, download the appropriate installation instructions. Preparation 1. Make sure surface is even without holes, gaps, etc. Make sure substrate has no cracks larger than 1/16" wide. Pay special attention to shrinkage cracks between the blocks and the mortar at the block s joints. 2. If necessary, apply a thin slurry coat using AVM Crete 6200. 3. Apply a 4"x4" mortar cant at 45 at the cold joints. (Where the block meets the footings) 4. Priming is highly recommended! Especially if surfaces are old, dusty or very dense (such as solid concrete) Always use AVM Primer 500 when installing over horizontal surfaces. Apply Primer using roller, brush or sprayer. Membrane Installation Roller/Brush: Apply a liberal coat of the Aussie Membrane 500 to all surfaces. (Roll up and down) Allow to cure until dry to the touch. Apply a second coat of the Aussie Membrane 500 going side to side. Allow to dry to the touch. Check for pinholes and proper thickness using a mil gauge. Make sure it=s a minimum 60 mils at all places when completely dry and 90 mils if still wet. Full cure is typically achieved after 24 hours. Drying times may vary based on temperature, humidity and other factors. Applying a third coat is highly recommended. Spray: Mix contents in bucket with drill and paddle for 30-60 seconds. Product will thin out significantly. (The thinning does not affect performance) Do NOT add water! Use an airless sprayer to apply. Apply product until saturated but stop before dripping or sagging occurs. Once dry to the touch, apply a second coat spraying in the other direction. Check for thickness. (60 mils dry / 90 mils wet) Important Notes: 1. 90 mils dry on vertical block walls is highly recommended. 2. Although it is possible to spray 60 dry mils in one coat, doing so in two coats reduces the chances of leaving spots and pinholes uncovered or with too little product. Quality Control a. Visually inspect all coated surfaces to ensure a full and proper coating application, especially at corners, drainage footings and other hard-to-reach areas. b. All unsatisfactory areas shall be repaired prior to final acceptance. Protection of Installed Work a. The completed section shall be protected for the first 24 hours after application or until the surface is sufficiently cured. (The amount of drying time may vary depending on temperature and humidity conditions) b. Always protect the waterproofing from possible damage. Install the AVM Drain Board 6000 and appropriate drainage system. Refer to Technical Details, Min Thickness Table and Installation Instructions for more info. Availability and Cost Contact AVM Industries or your approved applicator for pricing and availability. Technical Services Technical services are available by contacting our offices at: 888.414.1041 or 818.888.0050 or visit System Specifications See next page. Tech Data Sheet Rev. 09/2017 1/2 AVM Document # 30500-Retaining Walls

The following coverages are based on controlled tests. Actual coverages may vary. Technical Information Color Specific Gravity Coverage: (Varies depending on substrate) Flash Point Service Temperature Application Temperature Dark brown. After drying: black 1.189 gr/cm2 24 25 sq.ft./gal. @ 60 Dry Mills Non-flammable 15ºF-177ºF (-10ºC to +80ºC) 42ºF-132ºF (+5ºC to 55ºC) Solid Content 64% Tensile Strength >15.4 Lbs (>7 kg) ASTM D 412 Elongation at break >1000% ASTM D 412 Resistance to water pressure 1 tm 24 hr Passed ASTM D751 Water vapor transmission 4.0 gr/m2 24 hr ASTM D 96 Recovery 85% IS 1536 Creep At 177ºF (80ºC) No Creep DIN 52123 Resistance to Standing Water Passed ASTM D 2939 Bacterial Attack in soil 30 days @ 105ºF (40ºC) Passed ASTM D 2939 Crack bridging >3/16" (>5mm) IS 1731 Certifications ISO 9002, Green Label, I.Q. Net (International Certification Network) Item / Component Packaging Approx Shipping Weights VOC AVM Primer 500 2.0/5.0 gal. pails 2.0/5.0 gal. 15/39 lbs. 15 Grams/Liter AVM 5.0 gal. pails 5.0 gal. 52.5 lbs 19 Grams/Liter Slab on Grade at Top of Footing Earth Gravel Backfill (not required if drainage board used) Termination at Grade Backer Rod and Sealant by Others Concrete Wall Waterstop Slab on Grade over Vapor Barrier Drainage or Protection Board @ 60 mils *See note. Detail coat @ 45 ±5 mils with filter fabric Min 3 x3 Mortar Cant Strip Primer Termination Bar Paving with Protection or Drainage Board Gravel Perforated Drainage Pipe Top of Footing Less of Eq. 3 Note: For applications deeper than 6 feet, see Thickness Chart. For a complete list of details in CAD or PDF, please visit our website at. 888.414.1041 818.888.0050 Quality Waterproofing Products Tech Data Sheet Rev. 09/2017 2/2 AVM Document # 30500-Retaining Walls

Planters Spec TECH DATA SHEET Sections - 071000 / 071400 / 071416 ICC ESR-2503 L.A. RR#: 25550 Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections 071000 / 071400 / 071416 Fluid Applied Waterproofing Product Name Manufactured by 888.414.1041 818.888.0050 Product Description The AVM is a Water- Based rubber/bitumen liquid membrane modified with high performance rubberized polymers giving it excellent adhesion, which dries to a tough, black seamless flexible waterproof membrane. The Aussie Membrane 500 is a single component thixotropic coldapplied bitumen paste that exhibits excellent elongation and recovery properties. The AVM has excellent long-term stability (maintains its properties over very long periods of time) un-like other below grade systems (including polyurethane based systems) that Crack and become brittle as they age. Where to Use Planters: For waterproofing planters made of block or concrete. Important note: For Green Roofs (Roof Gardens) please refer to the Green Roofs Spec Data Sheet. Warranty AVM Industries will warranty the installed membrane for a period of five (5) years. Ten (10) year warranties are also available. For complete warranty details, contact AVM Industries or consult with your applicator. Delivery, Storage, and Handling a. Delivery of all the materials to the job site must be in their original sealed containers, with manufacturer s name and label intact. b. Handle and store containers in accordance with printed instructions. c. Store at temperatures between 50 F and 90 F. Do not store materials in direct sunlight or where they may be damaged by water or rain. d. Failure to comply with the recommended storage conditions may result in premature deterioration of the product. For specific storage advice, please contact AVM Industries and/or its representatives. e. Keep all materials out of the reach of children. f. If irritation occurs during use, liberally flush affected areas with water. If irritation continues, see a physician immediately. Project Conditions 1. All surfaces to which the Aussie Membrane 500 is applied to must be sound and stable, with an even finish and free from dust, loose debris, grease, curing agents, etc. 2. The may be applied to damp but not waterlogged surfaces (Green Concrete) 3. Do not apply materials at temperatures below 40 F and falling or if precipitation is imminent. Do not apply materials in direct sunlight at temperatures above 100 F or rising. 4. Warn personnel against hazards of materials to skin and eyes. Note other hazardous conditions on the job that might require special protective gear and or any other special protective or safety procedures. 5. Protect adjacent surfaces which could be damaged during the application procedure. 6. This system must not be used to cover Expansion Joints. System Application Read the Installation Instructions Prior to Installation. Application instructions vary based on application surfaces. Following are common (Generic) application procedures only. For specific application procedures, download the appropriate installation instructions. Preparation 1. Make sure surface is even without holes, gaps, etc. Make sure substrate has no cracks larger than 1/16" wide. Pay special attention to shrinkage cracks between the blocks and the mortar at the block s joints. 2. If necessary, apply a thin slurry coat using AVM Crete 6200. 3. Apply a 4"x4" mortar cant at 45 at the cold joints. (Where the block meets the footings) 4. Priming is highly recommended! Especially if surfaces are old, dusty or very dense (such as solid concrete) Always use AVM Primer 500 when installing over horizontal surfaces. Apply Primer using roller, brush or sprayer. Membrane Installation Roller/Brush: Apply a liberal coat of the Aussie Membrane 500 to all surfaces. (Roll up and down) Allow to cure until dry to the touch. Apply a second coat of the Aussie Membrane 500 going side to side. Allow to dry to the touch. Check for pinholes and proper thickness using a mil gauge. Make sure it=s a minimum 60 mils at all places when completely dry and 90 mils if still wet. Full cure is typically achieved after 24 hours. Drying times may vary based on temperature, humidity and other factors. Applying a third coat is highly recommended. Spray: Mix contents in bucket with drill and paddle for 30-60 seconds. Product will thin out significantly. (The thinning does not affect performance) Do NOT add water! Use an airless sprayer to apply. Apply product until saturated but stop before dripping or sagging occurs. Once dry to the touch, apply a second coat spraying in the other direction. Check for thickness. (60 mils dry / 90 mils wet) Important Notes: 1. 90 mils dry is highly recommended. 2. Although it is possible to spray 60 dry mils in one coat, doing so in two coats reduces the chances of leaving spots and pinholes uncovered or with too little product. Quality Control a. Visually inspect all coated surfaces to ensure a full and proper coating application, especially at corners, drainage footings and other hard-to-reach areas. b. All unsatisfactory areas shall be repaired prior to final acceptance. c. Perform a 24 hour water test whenever possible. Protection of Installed Work a. The completed section shall be protected for the first 24 hours after application or until the surface is sufficiently cured. (The amount of drying time may vary depending on temperature and humidity conditions) b. Always protect the waterproofing from possible damage. First install a root barrier (such as ¼ Apoc Protective Panels) or other approved root barrier. Then, on horizontal surfaces, install AVM Drain Board 9000. On vertical surfaces, install AVM Drain Board 6000. Refer to Technical Details, Min Thickness Table and Installation Instructions for more info. Availability and Cost Contact AVM Industries or your approved applicator for pricing and availability. Technical Services Technical services are available by contacting our offices at: 888.414.1041 or 818.888.0050 or visit System Specifications See next page. Tech Data Sheet Rev. 09/2017 1/2 AVM Document # 30500-Planters

The following coverages are based on controlled tests. Actual coverages may vary. Technical Information Color Specific Gravity Coverage: (Varies depending on substrate) Flash Point Service Temperature Application Temperature Dark brown. After drying: black 1.189 gr/cm2 24 25 sq.ft./gal. @ 60 Dry Mills Non-flammable 15ºF-177ºF (-10ºC to +80ºC) 42ºF-132ºF (+5ºC to 55ºC) Solid Content 64% Tensile Strength >15.4 Lbs (>7 kg) ASTM D 412 Elongation at break >1000% ASTM D 412 Resistance to water pressure 1 tm 24 hr Passed ASTM D751 Water vapor transmission 4.0 gr/m2 24 hr ASTM D 96 Recovery 85% IS 1536 Creep At 177ºF (80ºC) No Creep DIN 52123 Resistance to Standing Water Passed ASTM D 2939 Bacterial Attack in soil 30 days @ 105ºF (40ºC) Passed ASTM D 2939 Crack bridging >3/16" (>5mm) IS 1731 Certifications ISO 9002, Green Label, I.Q. Net (International Certification Network) Item / Component Packaging Approx Shipping Weights VOC AVM Primer 500 2.0/5.0 gal. pails 2.0/5.0 gal. 15/39 lbs. 15 Grams/Liter AVM 5.0 gal. pails 5.0 gal. 52.5 lbs 19 Grams/Liter SOIL PROTECTION BOARD OR DRAINAGE BOARD 60 MIL AVM SYSTEM 500 AUSSIE MEMBRANE 500 PRIMER 500 CONCRETE WEEP SCREED SHEET METAL FLASHING TERMINATION BAR SOIL PROTECTION BOARD OR AVM DRAINAGE BOARD 60 MIL AVM SYSTEM 500 AUSSIE MEMBRANE 500 PRIMER 500 EXTERIOR WALL PLANTER PLANTER PLANTER SLOPE CONCRETE TO DRAIN AVM SYSTEM 500 AUSSIE MEMBRANE 500 DETAIL COAT AT 45 ± 5 MILS WITH REINFORCING FABRIC MIN 3 X 3 MORTAR CANT STRIP OTHER ACCEPTABLE TERMINATIONAS For a complete list of details in CAD or PDF, please visit our website at. 888.414.1041 818.888.0050 Quality Waterproofing Products Tech Data Sheet Rev. 09/2017 2/2 AVM Document # 30500-Planters

Topping Slabs Waterproofing TECH DATA SHEET Sections - 071000 / 071400 / 071416 ICC ESR-2503 L.A. RR#: 25550 Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections 071000 / 071400 / 071416 Fluid Applied Waterproofing Product Name Manufactured by 888.414.1041 818.888.0050 Product Description The AVM is a Water- Based rubber/bitumen liquid membrane modified with high performance rubberized polymers giving it excellent adhesion, which dries to a tough, black seamless flexible waterproof membrane. The Aussie Membrane 500 is a single component thixotropic coldapplied bitumen paste that exhibits excellent elongation and recovery properties. The AVM has excellent long-term stability (maintains its properties over very long periods of time) un-like other below grade systems (including polyurethane based systems) that Crack and become brittle as they age. Where to Use Between Slabs / Topping Slabs / Hard Rock: For waterproofing between two slabs, under topping slabs, under hard rock and other sandwiched applications. Important notes: May be applied over concrete or plywood substrates. (See details) Warranty AVM Industries will warranty the installed membrane for a period of five (5) years. Ten (10) year warranties are also available. For complete warranty details, contact AVM Industries or consult with your applicator. Delivery, Storage, and Handling a. Delivery of all the materials to the job site must be in their original sealed containers, with manufacturer s name and label intact. b. Handle and store containers in accordance with printed instructions. c. Store at temperatures between 50 F and 90 F. Do not store materials in direct sunlight or where they may be damaged by water or rain. d. Failure to comply with the recommended storage conditions may result in premature deterioration of the product. For specific storage advice, please contact AVM Industries and/or its representatives. e. Keep all materials out of the reach of children. f. If irritation occurs during use, liberally flush affected areas with water. If irritation continues, see a physician immediately. Project Conditions 1. All surfaces to which the Aussie Membrane 500 is applied to must be sound and stable, with an even finish and free from dust, loose debris, grease, curing agents, etc.. 2. The may be applied to damp but not waterlogged surfaces (Green Concrete) 3. Do not apply materials at temperatures below 40 F and falling or if precipitation is imminent. Do not apply materials in direct sunlight at temperatures above 100 F or rising. 4. Warn personnel against hazards of materials to skin and eyes. Note other hazardous conditions on the job that might require special protective gear and or any other special protective or safety procedures. 5. Protect adjacent surfaces which could be damaged during the application procedure. 6. This system must not be used to cover Expansion Joints. System Application Read the Installation Instructions Prior to Installation. Application instructions vary based on application surfaces. Following are common (Generic) application instructions for applications over concrete only. For detailed installation instructions, download the appropriate installation instructions. Preparation 1. Make sure concrete surfaces are even without holes, gaps, etc. Make sure substrate has no cracks larger than 1/16 wide. (If applying over plywood substrates, refer to the Between Slab Installation Instructions and Details for more information) 2. If necessary, apply a thin slurry coat using AVM Crete 6200. 3. Apply a 1x1 mortar cant at 45 at horizontalto-vertical transitions. Then apply a detail coat. (See details) 4. Primer: Apply AVM Primer 500 using a roller, brush or sprayer to all surfaces and allow to dry to the touch before installing the Aussie Membrane 500. Membrane Installation Roller/Brush: Apply liberal coats of the Aussie Membrane 500 to all surfaces until the desired thickness is achieved. (see AVM Aussie Membrane 500 500 Min Thickness Table for more info) Allow to cure between coats. Check for pinholes, bubbles and proper thickness using a mil gauge. Fix any imperfections as needed. Full cure is typically achieved after 24-48 hours after the final coat was installed. Drying times may vary based on temperature, humidity and other factors. Spray: Mix contents in bucket with drill and paddle for 30-60 seconds. Product will thin out significantly. (The thinning does not affect performance) Do NOT add water! Use an airless sprayer to apply. Apply product until saturated but stop before dripping or sagging occurs. Once dry to the touch, apply a second coat spraying in the other direction. Continue to apply coats until the desired thickness is achieved. Important Notes: It s better to apply multiple thin coats Vs. one or two thick coats. Applying coats too thick could cause material to crust over and slow down curing times. It could also lead to bubbling and delaminations. Quality Control a. Visually inspect all coated surfaces to ensure a full and proper coating application, especially at corners, drainage footings and other hard-to-reach areas. b. All unsatisfactory areas shall be repaired prior to final acceptance. Protection of Installed Work a. The completed section shall be protected for the first 24 hours after application or until the surface is sufficiently cured. (The amount of drying time may vary depending on temperature and humidity conditions) b. Always protect the waterproofing from possible damage. Install optional protective Panels and appropriate AVM Drainage Boards. Refer to Technical Details, Min Thickness Table and Installation Instructions for more info. Availability and Cost Contact AVM Industries or your approved applicator for pricing and availability. Technical Services Technical services are available by contacting our offices at: 888.414.1041 or 818.888.0050 or visit System Specifications See next page. Tech Data Sheet Rev. 09/2017 1/2 AVM Document # 30500-Topping Slabs

The following coverages are based on controlled tests. Actual coverages may vary. Technical Information Color Specific Gravity Coverage: (Varies depending on substrate) Flash Point Service Temperature Application Temperature Dark brown. After drying: black 1.189 gr/cm2 24 25 sq.ft./gal. @ 60 Dry Mills Non-flammable 15ºF-177ºF (-10ºC to +80ºC) 42ºF-132ºF (+5ºC to 55ºC) Solid Content 64% Tensile Strength >15.4 Lbs (>7 kg) ASTM D 412 Elongation at break >1000% ASTM D 412 Resistance to water pressure 1 tm 24 hr Passed ASTM D751 Water vapor transmission 4.0 gr/m2 24 hr ASTM D 96 Recovery 85% IS 1536 Creep At 177ºF (80ºC) No Creep DIN 52123 Resistance to Standing Water Passed ASTM D 2939 Bacterial Attack in soil 30 days @ 105ºF (40ºC) Passed ASTM D 2939 Crack bridging >3/16" (>5mm) IS 1731 Certifications ISO 9002, Green Label, I.Q. Net (International Certification Network) Item / Component Packaging Approx Shipping Weights VOC AVM Primer 500 2.0/5.0 gal. pails 2.0/5.0 gal. 15/39 lbs. 15 Grams/Liter AVM 5.0 gal. pails 5.0 gal. 52.5 lbs 19 Grams/Liter Topping slab Topping slab Min. 120 mil fully reinforced (consult w/avm for membrane thickness requirements) Min. 120 mil fully reinforced (consult w/avm for membrane thickness requirements) For a complete list of details in CAD or PDF, please visit our website at. 888.414.1041 818.888.0050 Quality Waterproofing Products Tech Data Sheet Rev. 09/2017 2/2 AVM Document # 30500-Topping Slabs